1
|
Shoshani T, Faerman A, Mett I, Zelin E, Tenne T, Gorodin S, Moshel Y, Elbaz S, Budanov A, Chajut A, Kalinski H, Kamer I, Rozen A, Mor O, Keshet E, Leshkowitz D, Einat P, Skaliter R, Feinstein E. Identification of a novel hypoxia-inducible factor 1-responsive gene, RTP801, involved in apoptosis. Mol Cell Biol 2002; 22:2283-93. [PMID: 11884613 PMCID: PMC133671 DOI: 10.1128/mcb.22.7.2283-2293.2002] [Citation(s) in RCA: 445] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Hypoxia is an important factor that elicits numerous physiological and pathological responses. One of the major gene expression programs triggered by hypoxia is mediated through hypoxia-responsive transcription factor hypoxia-inducible factor 1 (HIF-1). Here, we report the identification and cloning of a novel HIF-1-responsive gene, designated RTP801. Its strong up-regulation by hypoxia was detected both in vitro and in vivo in an animal model of ischemic stroke. When induced from a tetracycline-repressible promoter, RTP801 protected MCF7 and PC12 cells from hypoxia in glucose-free medium and from H(2)O(2)-triggered apoptosis via a dramatic reduction in the generation of reactive oxygen species. However, expression of RTP801 appeared toxic for nondividing neuron-like PC12 cells and increased their sensitivity to ischemic injury and oxidative stress. Liposomal delivery of RTP801 cDNA to mouse lungs also resulted in massive cell death. Thus, the biological effect of RTP801 overexpression depends on the cell context and may be either protecting or detrimental for cells under conditions of oxidative or ischemic stresses. Altogether, the data suggest a complex type of involvement of RTP801 in the pathogenesis of ischemic diseases.
Collapse
|
research-article |
23 |
445 |
2
|
Nahmad A, Reuveni E, Goldschmidt E, Tenne T, Liberman M, Horovitz-Fried M, Khosravi R, Kobo H, Reinstein E, Madi A, Ben-David U, Barzel A. Frequent aneuploidy in primary human T cells after CRISPR-Cas9 cleavage. Nat Biotechnol 2022; 40:1807-1813. [PMID: 35773341 PMCID: PMC7613940 DOI: 10.1038/s41587-022-01377-0] [Citation(s) in RCA: 99] [Impact Index Per Article: 33.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 05/31/2022] [Indexed: 01/14/2023]
Abstract
Multiple clinical trials of allogeneic T cell therapy use site-specific nucleases to disrupt T cell receptor (TCR) and other genes1-6. In this study, using single-cell RNA sequencing, we investigated genome editing outcomes in primary human T cells transfected with CRISPR-Cas9 and guide RNAs targeting genes for TCR chains and programmed cell death protein 1. Four days after transfection, we found a loss of chromosome 14, harboring the TCRα locus, in up to 9% of the cells and a chromosome 14 gain in up to 1.4% of the cells. Chromosome 7, harboring the TCRβ locus, was truncated in 9.9% of the cells. Aberrations were validated using fluorescence in situ hybridization and digital droplet PCR. Aneuploidy was associated with reduced proliferation, induced p53 activation and cell death. However, at 11 days after transfection, 0.9% of T cells still had a chromosome 14 loss. Aneuploidy and chromosomal truncations are, thus, frequent outcomes of CRISPR-Cas9 cleavage that should be monitored and minimized in clinical protocols.
Collapse
|
research-article |
3 |
99 |
3
|
Elkon R, Rashi-Elkeles S, Lerenthal Y, Linhart C, Tenne T, Amariglio N, Rechavi G, Shamir R, Shiloh Y. Dissection of a DNA-damage-induced transcriptional network using a combination of microarrays, RNA interference and computational promoter analysis. Genome Biol 2005; 6:R43. [PMID: 15892871 PMCID: PMC1175955 DOI: 10.1186/gb-2005-6-5-r43] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2004] [Revised: 02/03/2005] [Accepted: 03/08/2005] [Indexed: 01/19/2023] Open
Abstract
BACKGROUND Gene-expression microarrays and RNA interferences (RNAi) are among the most prominent techniques in functional genomics. The combination of the two holds promise for systematic, large-scale dissection of transcriptional networks. Recent studies, however, raise the concern that nonspecific responses to small interfering RNAs (siRNAs) might obscure the consequences of silencing the gene of interest, throwing into question the ability of this experimental strategy to achieve precise network dissections. RESULTS We used microarrays and RNAi to dissect a transcriptional network induced by DNA damage in a human cellular system. We recorded expression profiles with and without exposure of the cells to a radiomimetic drug that induces DNA double-strand breaks (DSBs). Profiles were measured in control cells and in cells knocked-down for the Rel-A subunit of NFkappaB and for p53, two pivotal stress-induced transcription factors, and for the protein kinase ATM, the major transducer of the cellular responses to DSBs. We observed that NFkappaB and p53 mediated most of the damage-induced gene activation; that they controlled the activation of largely disjoint sets of genes; and that ATM was required for the activation of both pathways. Applying computational promoter analysis, we demonstrated that the dissection of the network into ATM/NFkappaB and ATM/p53-mediated arms was highly accurate. CONCLUSIONS Our results demonstrate that the combined experimental strategy of expression arrays and RNAi is indeed a powerful method for the dissection of complex transcriptional networks, and that computational promoter analysis can provide a strong complementary means for assessing the accuracy of this dissection.
Collapse
|
Evaluation Study |
20 |
66 |
4
|
Sagi-Dain L, Cohen Vig L, Kahana S, Yacobson S, Tenne T, Agmon-Fishman I, Klein C, Matar R, Basel-Salmon L, Maya I. Chromosomal microarray vs. NIPS: analysis of 5541 low-risk pregnancies. Genet Med 2019; 21:2462-2467. [PMID: 31123319 DOI: 10.1038/s41436-019-0550-x] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Accepted: 05/10/2019] [Indexed: 12/18/2022] Open
Abstract
PURPOSE To evaluate the diagnostic yield of chromosomal microarray (CMA) in pregnancies with normal ultrasound. METHODS This retrospective cohort analysis included all pregnancies with normal ultrasound undergoing CMA testing between the years 2010 and 2016. We calculated the rate of detection of clinically significant CMA findings in the whole cohort and according to various indications. RESULTS Of 5541 CMA analyses, clinically significant findings were yielded in 78 cases (1.4%). Of these, 31 (39.7%) variants could have theoretically been detected by karyotyping (e.g., sized above 10 Mb), and 28 (35.9%) by noninvasive prenatal screening aimed at five common aneuploidies. Of the 47 submicroscopic findings detectable by CMA only, the majority (37 cases, 78.7%) represented known recurrent syndromes. Detection of clinically significant CMA findings in women with no indication for invasive testing was 0.76% (21/2752), which was significantly lower compared with 1.8% in advanced maternal age group (41/2336), 2.8% in abnormal biochemical serum screening (6/211), and 4.1% (10/242) in fetuses with sonographic soft markers. CONCLUSION Clinically significant CMA aberrations are detected in 1 of 71 pregnancies with normal ultrasound, and in 1 of 131 women with no indication for invasive testing. Thus, CMA might be recommended a first-tier test in pregnancies with normal ultrasound.
Collapse
|
|
6 |
54 |
5
|
Maya I, Sharony R, Yacobson S, Kahana S, Yeshaya J, Tenne T, Agmon-Fishman I, Cohen-Vig L, Goldberg Y, Berger R, Basel-Salmon L, Shohat M. When genotype is not predictive of phenotype: implications for genetic counseling based on 21,594 chromosomal microarray analysis examinations. Genet Med 2017; 20:128-131. [PMID: 28726807 DOI: 10.1038/gim.2017.89] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Accepted: 05/02/2017] [Indexed: 12/11/2022] Open
Abstract
PurposeTo compare the frequency of copy-number variants (CNVs) of variable penetrance in low-risk and high-risk prenatal samples and postnatal samples.MethodsTwo cohorts were categorized according to chromosomal microarray analysis (CMA) indication: group I, low-risk prenatal-women with uneventful pregnancy (control group); group II, high-risk prenatal-women whose fetuses had congenital malformations; and group III, postnatal-individuals with unexplained developmental delay/intellectual disability, autism spectrum disorders, or multiple congenital anomalies. CNVs were categorized based on clinical penetrance: (i) high (>40%), (ii) moderate (10-40%), and (iii) low (<10%).ResultsFrom 2013 to 2016, 21,594 CMAs were performed. The frequency of high-penetrance CNVs was 0.1% (21/15,215) in group I, 0.9% (26/2,791) in group II, and 2.6% (92/3,588) in group III. Moderate-penetrance CNV frequency was 0.3% (47/15,215), 0.6% (19/2,791), and 1.2% (46/3,588), respectively. These differences were statistically significant. The frequency of low-penetrance CNVs was not significantly different among groups: 0.6% (85/15,215), 0.9% (25/2,791), and 1.0% (35/3,588), respectively.ConclusionHigh-penetrance CNVs might be a major factor in the overall heritability of developmental, intellectual, and structural anomalies. Low-penetrance CNV alone does not seem to contribute to these anomalies. These data may assist pre- and posttest CMA counseling.
Collapse
|
Research Support, Non-U.S. Gov't |
8 |
51 |
6
|
Maya I, Yacobson S, Kahana S, Yeshaya J, Tenne T, Agmon-Fishman I, Cohen-Vig L, Shohat M, Basel-Vanagaite L, Sharony R. Cut-off value of nuchal translucency as indication for chromosomal microarray analysis. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2017; 50:332-335. [PMID: 28133835 DOI: 10.1002/uog.17421] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2016] [Revised: 01/03/2017] [Accepted: 01/18/2017] [Indexed: 06/06/2023]
Abstract
OBJECTIVES An association between isolated, increased nuchal translucency thickness (NT) and pathogenic findings on chromosomal microarray analysis (CMA) has been reported. A recent meta-analysis reported that most studies use a NT cut-off value of 3.5 mm. However, considering NT distribution and the commonly accepted 5% false-positive rate in maternal serum screening, NT cut-off levels should be reconsidered. The aim of this study was to assess different NT cut-off levels as indication for CMA and to determine whether CMA should be recommended for mildly increased NT of 3.0-3.4 mm. METHODS This was a retrospective, multicenter study of singleton pregnancies with CMA results and either normal NT and no other finding or with increased NT as the only medical indication for CMA at the time of an invasive procedure (increased NT was considered an isolated finding in cases of advanced maternal age). Women with normal fetal NT who underwent CMA did so at their own request. A single laboratory performed all genetic analyses. Comparative genomic hybridization microarray analysis or single nucleotide polymorphism array technology was used for CMA. If combined first-trimester screening (NT and biochemistry) indicated increased risk for common aneuploidies, the case was excluded. NT was used to divide cases into three groups (≤ 2.9 mm, 3.0-3.4 mm and ≥ 3.5 mm) and their CMA results were compared. RESULTS CMA results were recorded in 1588 pregnancies, among which 770 fetuses had either normal NT with no other finding or isolated increased NT. Of these, 462 had NT ≤ 2.9 mm, 170 had NT of 3.0-3.4 mm and 138 had NT ≥ 3.5 mm. Pathogenic copy number variants were found in 1.7%, 6.5% and 13.8% of cases, respectively. CONCLUSION Our results suggest that CMA should be recommended when fetuses have isolated, mildly increased NT (3.0-3.4 mm). Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
|
Evaluation Study |
8 |
41 |
7
|
Maya I, Kahana S, Yeshaya J, Tenne T, Yacobson S, Agmon-Fishman I, Cohen-Vig L, Levi A, Reinstein E, Basel-Vanagaite L, Sharony R. Chromosomal microarray analysis in fetuses with aberrant right subclavian artery. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2017; 49:337-341. [PMID: 27063194 DOI: 10.1002/uog.15935] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Revised: 03/29/2016] [Accepted: 04/05/2016] [Indexed: 06/05/2023]
Abstract
OBJECTIVE To evaluate the association between aberrant right subclavian artery (ARSA), with or without additional risk factors for aneuploidy or ultrasound abnormality, and results of chromosomal microarray analysis (CMA). METHODS This was a multicenter study of fetuses diagnosed with ARSA that underwent genetic analysis by CMA, all samples being analyzed in the same laboratory. Clinical investigation included nuchal translucency measurement, first- and second-trimester maternal serum screening, early and late second-trimester fetal anatomy scans and fetal echocardiography. Comparative genomic hybridization microarray analysis or single-nucleotide polymorphism array technology was used for CMA of DNA samples obtained from amniotic fluid. RESULTS CMA results were available for 63 fetuses with ARSA. In 36 fetuses, ARSA was an isolated finding, and no pathogenic variant was found. Additional ultrasound findings and/or risk factors for aneuploidy were present in 27 fetuses, five of which had pathogenic CMA results. Of these five, trisomy 21 was detected in a fetus with echogenic intracardiac focus (EIF), 22q11 deletion was detected in a fetus with EIF and an increased risk of trisomy 21 of 1:230 from maternal serum screening, 22q11 duplication was detected in a fetus with hypoplastic right kidney and choroid plexus cyst and 22q11 deletion was detected in a fetus with right aortic arch and clubfoot. The fifth fetus had increased nuchal translucency thickness (4 mm) and a ventricular septal defect, and CMA identified both 22q11 deletion and 1q21 duplication. CONCLUSIONS In fetuses with isolated ARSA, an invasive procedure for CMA is not indicated. However, CMA is recommended when additional ultrasound abnormalities or risk factors for aneuploidy are observed. The chromosomal findings in four of the five cases with an abnormal CMA result in our study would not have been detected by standard fetal chromosomal testing. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
|
Multicenter Study |
8 |
33 |
8
|
Stojadinović B, Tenne T, Zikich D, Rajković N, Milošević N, Lazović B, Žikić D. Effect of viscosity on the wave propagation: Experimental determination of compression and expansion pulse wave velocity in fluid-fill elastic tube. J Biomech 2015; 48:3969-3974. [PMID: 26454712 DOI: 10.1016/j.jbiomech.2015.09.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Revised: 09/09/2015] [Accepted: 09/24/2015] [Indexed: 01/09/2023]
Abstract
The velocity by which the disturbance travels through the medium is the wave velocity. Pulse wave velocity is one of the main parameters in hemodynamics. The study of wave propagation through the fluid-fill elastic tube is of great importance for the proper biophysical understanding of the nature of blood flow through of cardiovascular system. The effect of viscosity on the pulse wave velocity is generally ignored. In this paper we present the results of experimental measurements of pulse wave velocity (PWV) of compression and expansion waves in elastic tube. The solutions with different density and viscosity were used in the experiment. Biophysical model of the circulatory flow is designed to perform measurements. Experimental results show that the PWV of the expansion waves is higher than the compression waves during the same experimental conditions. It was found that the change in viscosity causes a change of PWV for both waves. We found a relationship between PWV, fluid density and viscosity.
Collapse
|
|
10 |
8 |
9
|
Maya I, Perlman S, Shohat M, Kahana S, Yacobson S, Tenne T, Agmon-Fishman I, Tomashov Matar R, Basel-Salmon L, Sukenik-Halevy R. Should We Report 15q11.2 BP1-BP2 Deletions and Duplications in the Prenatal Setting? J Clin Med 2020; 9:jcm9082602. [PMID: 32796639 PMCID: PMC7463673 DOI: 10.3390/jcm9082602] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 07/22/2020] [Accepted: 08/05/2020] [Indexed: 12/26/2022] Open
Abstract
Copy number variations of the 15q11.2 region at breakpoints 1-2 (BP1-BP2) have been associated with variable phenotypes and low penetrance. Detection of such variations in the prenatal setting can result in significant parental anxiety. The clinical significance of pre- and postnatally detected 15q11.2 BP1-BP2 deletions and duplications was assessed. Of 11,004 chromosomal microarray tests performed in a single referral lab (7596 prenatal, 3408 postnatal), deletions were detected in 66 cases: 39 in prenatal tests (0.51%) and 27 in postnatal tests (0.79%). Duplications were detected in 94 cases: 62 prenatal tests (0.82%) and 32 postnatal tests (0.94%). The prevalence of deletions and duplications among clinically indicated prenatal tests (0.57% and 0.9%, respectively) did not differ significantly in comparison to unindicated tests (0.49% and 0.78%, respectively). The prevalence of deletions and duplications among postnatal tests performed for clinical indications was similar to the prevalence in healthy individuals (0.73% and 1% vs. 0.98% and 0.74%, respectively). The calculated penetrance of deletions and duplications over the background risk was 2.18% and 1.16%, respectively. We conclude that the pathogenicity of 15q11.2 BP1-BP2 deletions and duplications is low. Opting out the report of these copy number variations to both clinicians and couples should be considered.
Collapse
|
Journal Article |
5 |
8 |
10
|
Reinstein E, Liberman M, Feingold-Zadok M, Tenne T, Graham JM. Terminal microdeletions of 13q34 chromosome region in patients with intellectual disability: Delineation of an emerging new microdeletion syndrome. Mol Genet Metab 2016; 118:60-3. [PMID: 27067448 DOI: 10.1016/j.ymgme.2016.03.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Revised: 03/20/2016] [Accepted: 03/20/2016] [Indexed: 12/23/2022]
Abstract
The increasing use of chromosomal microarray studies in patients with intellectual disability has led to the description of new microdeletion and microduplication syndromes. We report terminal microdeletions in 13q34 chromosome region in 5 adult patients of two unrelated families. Patients harboring 13q34 microdeletions display common clinical features, including intellectual disability, obesity, and mild facial dysmorphism. These individuals can become fairly self-sufficient, however they do not live independently, and require community and social support. Further systematic analysis of the genes comprised in the deleted region will allow the identification of genes whose haploinsufficiency is expected to lead to disease manifestations, in particular intellectual disability.
Collapse
|
|
9 |
7 |
11
|
Djurić B, Suzić S, Stojadinović B, Nestorović Z, Ivanović M, Suzić-Lazić J, Nešić D, Mazić S, Tenne T, Zikich D, Žikić D. An improved design of optical sensor for long-term measurement of arterial blood flow waveform. Biomed Microdevices 2017; 19:48. [PMID: 28560700 DOI: 10.1007/s10544-017-0196-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
We present here the improved design and development of optical sensor for non-invasive measurements of arterial blood flow waveform. The sensor is based on a physical principle of reflective photoplethysmography (PPG). As the light source we used serially connected infrared diodes whereas NPN silicon phototransistors were used as light detectors. The electronic components were molded into square package and poured with silicone. Such preparation produced an elastic superficies that allowed excellent attachment of the sensor on the skin's surface. Moreover, a serial connection of infrared diodes and phototransistors completely eliminated signal artifacts caused by minor muscle contractions. The sensor recording performances were examined at the photoplethysmographic sites on three different arteries; the commune carotid, femoral and radial and, on each site the sensor demonstrated remarkable capability to make a consistent, reproducible measurements. Because of the advantageous physical and electrical properties, the new sensor is suitable for various cardiovascular diagnostics procedures, especially when long-term measurements of arterial blood flow waveform are required, for monitoring of different parameters in cardiovascular units and for research.
Collapse
|
|
8 |
4 |
12
|
Pasternak Y, Daykan Y, Tenne T, Reinstein E, Miller N, Shechter-Maor G, Maya I, Biron-Shental T, Sukenik Halevy R. The yield of chromosomal microarray analysis among pregnancies terminated due to fetal malformations. J Matern Fetal Neonatal Med 2020; 35:336-340. [PMID: 31973614 DOI: 10.1080/14767058.2020.1716722] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Background: Chromosomal microarray analysis (CMA) is preferred for genetic work-up when fetal malformations are detected prenatally.Objectives: To assess the detection rate of CMA after pregnancy termination due to abnormal ultrasound findings.Methods: CMA was successfully performed in 71 pregnancies using fetal DNA (mainly from skin) or placenta. Data regarding clinical background, pregnancy work-up, and CMA were analyzed.Results: Findings were abnormal in 17 cases (23.9%), of which 13 were detectable by karyotype. The incremental yield of CMA was 4/71 (5.6%); 1/32 (3.1%) for cases with an isolated anomaly and 3/39 (7.7%) for cases with nonisolated anomalies.Conclusions: CMA yield from terminated pregnancies was 23.9%. Although most chromosomal abnormalities are detectable by karyotype, CMA does not require viable dividing cells; hence, it is more practical for work-up after termination. In most cases, the diagnosis was followed by consultation regarding the risk of recurrence and recommendations for testing in subsequent pregnancies.
Collapse
|
Journal Article |
5 |
3 |
13
|
Singer A, Maya I, Sukenik-Halevy R, Tenne T, Lev D, Ben Shachar S, Sagi-Dain L. Microarray findings in pregnancies with oligohydramnios - a retrospective cohort study and literature review. J Perinat Med 2019; 48:53-58. [PMID: 31811807 DOI: 10.1515/jpm-2019-0228] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2019] [Accepted: 11/04/2019] [Indexed: 01/02/2023]
Abstract
Objective To explore the risk for abnormal chromosomal microarray analysis (CMA) findings in pregnancies with oligohydramnios. Methods Data from all CMA analyses performed due to oligohydramnios between 2013 and 2017 were retrospectively obtained from the Israeli Ministry of Health database. The rate of clinically significant (pathogenic and likely pathogenic) findings was compared to a local cohort of pregnancies with normal ultrasound, yielding a 1.4% rate of abnormal CMA results. In addition, a search was conducted through the PubMed database addressing the issue. Results Fifty CMA analyses were performed due to oligohydramnios. The 2% risk for clinically significant CMA finding in pregnancies with oligohydramnios did not differ from the control population of 5541 pregnancies with normal ultrasound - relative risk (RR) 1.4 [95% confidence interval (CI) 0.2-10.2]. Literature search yielded 394 titles, of which four relevant articles were selected, all using fetal karyotyping. Conclusion There is yet insufficient evidence to support invasive prenatal testing in pregnancies with isolated oligohydramnios.
Collapse
|
Review |
6 |
3 |
14
|
Gofin Y, Svirsky R, Lavi Ben Atav D, Liberman M, Tenne T, Perlman S, Sukenik-Halevy R. DNA concentrations in amniotic fluid according to gestational age and fetal sex: data from 2573 samples. Arch Gynecol Obstet 2024; 310:1981-1987. [PMID: 39210070 PMCID: PMC11393111 DOI: 10.1007/s00404-024-07698-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Accepted: 08/15/2024] [Indexed: 09/04/2024]
Abstract
PURPOSE In some cases of prenatal genetic testing, an ample amount of fetal DNA is needed, to allow for parallel testing (conducting several genetic tests simultaneously). This study investigated the association between amniotic fluid DNA concentration and various factors. We aimed to define the required amount of amniotic fluid to be extracted in amniocentesis, to allow parallel testing throughout gestational weeks. METHODS DNA concentration was analyzed from amniocentesis samples taken during the years 2016-2022. Sex association was also analyzed in postnatal whole blood samples from a separate cohort. Theoretical minimum volume of amniotic fluid needed to ensure enough DNA for chromosomal microarray analysis and exome sequencing was calculated. RESULTS We focused our analysis on 2573 samples, which were taken during weeks 17-23 and 30-35. DNA concentrations increased from weeks 17 to 21, with relatively stable concentrations thereafter. Significantly higher DNA concentrations were seen in pregnancies of female fetuses. DNA concentrations in postnatal whole blood samples did not show this association. Across most weeks, the volume needed to extract 2 µg of DNA from 95% of the samples was about 34 ml. CONCLUSION DNA concentrations in amniotic fluid vary according to gestational age and are higher in pregnancies of female fetuses. This should be considered when determining the volume of fluid extracted and the timing of amniocentesis, with greater volumes needed in earlier stages of pregnancy.
Collapse
|
research-article |
1 |
|
15
|
Pasternak Y, Daykan Y, Tenne T, Reinstein E, Miller N, Shechter-Maor G, Maya I, Biron-Shental T, Halevy RS. 389: The yield of Chromosomal microarray analysis in cases of pregnancy termination due to fetal malformations. Am J Obstet Gynecol 2019. [DOI: 10.1016/j.ajog.2018.11.410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
|
6 |
|