1
|
Scalioni LDP, Cruz HM, de Paula VS, Miguel JC, Marques VA, Villela-Nogueira CA, Milagres FAP, Cruz MS, Bastos FI, Andrade TM, Motta-Castro ARC, Lewis-Ximenez LL, Lampe E, Villar LM. Performance of rapid hepatitis C virus antibody assays among high- and low-risk populations. J Clin Virol 2014; 60:200-205. [PMID: 24794796 DOI: 10.1016/j.jcv.2014.04.001] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2013] [Revised: 03/18/2014] [Accepted: 04/02/2014] [Indexed: 12/11/2022]
Abstract
BACKGROUND Rapid tests for the detection of antibodies to hepatitis C virus (anti-HCV) can facilitate access to diagnosis. OBJECTIVES This study aimed to evaluate the performance of rapid tests for anti-HCV detection in the sera, whole blood, and oral fluid samples from individuals with different endemicity profiles and risk behaviors. STUDY DESIGN Three groups donated biological samples that were tested using three anti-HCV rapid tests (WAMA, Bioeasy and OraSure): (I) suspected cases of hepatitis C, (II) individuals who were living in remote areas in Brazil and (III) crack users and beauty professionals. Reproducibility, repeatability and cross-reactivity to other infectious agents (dengue, HIV, malaria, and syphilis) were also evaluated. RESULTS In group I, specificities varied from 93.75% to 100% and sensitivities varied from 76.03% to 93.84% according to the EIA results. When anti-HCV/HCV RNA-reactive sera samples were considered true-positive HCV cases, the sensitivities and specificities varied from 86.3% to 99.09% and 93.75% to 100%, respectively. In group II, the OraSure rapid test presented the best performance. In group III, the Bioeasy assay performed best using saliva and whole blood and the OraSure assay performed best using oral fluid samples. The reproducibility and repeatability of the WAMA and Bioeasy tests were excellent. The level of concordance between the HCV EIAs and the rapid tests using samples that were reactive for other infectious agents varied from 82.35% to 100% for the WAMA assay and 94.11% to 100% for the Bioeasy assay. CONCLUSION All of the rapid tests could be used to identify active HCV infection among individuals with different endemicity profiles and risk behaviors.
Collapse
|
|
11 |
32 |
2
|
Brandão CPU, Marques BLC, Marques VA, Villela-Nogueira CA, Do Ó KMR, de Paula MT, Lewis-Ximenez LL, Lampe E, Sá Ferreira JA, Villar LM. Simultaneous detection of hepatitis C virus antigen and antibodies in dried blood spots. J Clin Virol 2013; 57:98-102. [PMID: 23518440 DOI: 10.1016/j.jcv.2013.02.014] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2012] [Revised: 02/14/2013] [Accepted: 02/21/2013] [Indexed: 12/12/2022]
Abstract
BACKGROUND Enzyme immunoassays (EIA) designed to detect hepatitis C virus (HCV) core antigen and anti-HCV antibodies (HCV AgAb) simultaneously can improve the early detection of HCV infection when molecular diagnostic methods are not widely available. OBJECTIVES To evaluate the suitability of dried blood spot (DBS) samples for detecting HCV AgAb using commercial EIAs. STUDY DESIGN Paired serum and DBS samples were assayed using two commercial EIAs for HCV AgAb (Monolisa™ HCV AgAb ULTRA and Murex HCV AgAb). Manufacturer's recommendations were followed for sera while sample volume, incubation time and cut-off (CO) determination were evaluated for the DBS samples. The values of sensitivity, specificity, inter-rater agreement, detection limit, assay precision and stability of DBS samples at different conditions (22-26°C, 2-8°C and -20°C) were determined. RESULTS It was necessary to increase the DBS sample volume fourfold compared to the sera samples to approximate the DBS Optical Density (OD) values to the sera OD values. Using ROC curve to recalculate CO values for the DBS samples, sensitivity was 97.5% for both EIAs, while the specificity was 99.71% for Monolisa™ HCV AgAb ULTRA and 95.95% for Murex HCV AgAb. Accurate testing results were obtained with DBS samples for 60 days at all conditions evaluated; storage at -20°C resulted in low OD variation. Both EIAs demonstrated the same limit of detection among DBS samples [estimated viral load of 3.1 International Units per millilitre (IU/mL)] and low OD value variability in repetitivity and reproducibility studies. CONCLUSION DBS samples can be used for the detection of HCV AgAb by EIA as they present comparable performance characteristics and excellent stability among various storage conditions.
Collapse
|
Evaluation Study |
12 |
32 |
3
|
Marques BLC, Brandão CU, Silva EF, Marques VA, Villela-Nogueira CA, Do Ó KMR, de Paula MT, Lewis-Ximenez LL, Lampe E, Villar LM. Dried blood spot samples: optimization of commercial EIAs for hepatitis C antibody detection and stability under different storage conditions. J Med Virol 2012; 84:1600-1607. [PMID: 22930508 DOI: 10.1002/jmv.23379] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
This study was undertaken to optimize and compare the efficiency of two commercial EIAs for anti-HCV detection (HCV Ab Radim, Pomezzia, Italy and ETI-AB-HCVK-4 DiaSorin, Vercelli, Italy), in dried blood spot (DBS) samples. The long-term stability of anti-HCV on DBS samples stored at three environmental conditions was also evaluated at: 2-8 °C, 20-25 °C, and -20 °C. Paired DBS and serum samples were obtained from individuals with or without anti-HCV. The type of elution buffer, sample and conjugate volume, sample incubation time and cut-off values were evaluated. For both EIAs, a larger sample volume was used, and the cut-off value determined by the manufacturer was employed for Radim EIA; however, ROC curve analysis was used for the DiaSorin EIA. The sensitivity and specificity of Radim EIA on DBS were 97.5% and 99.5%, respectively, and of DiaSorin EIA were 88.9% and 98.9%, respectively. Accurate results were obtained for a period of 117 days using DBS samples stored at all storage conditions, but storage at -20 °C resulted in the lowest variation among the absorbance values. Both EIAs demonstrated the same limit of detection (until dilution of 1:10(4) with estimated viral load of 3.1 × 10(-1) UI/ml), but the Radim EIA was associated with the best performance because a low coefficient of variation was observed in the repetition and reproducibility studies. In conclusion, commercial EIAs can be optimized for anti-HCV detection in DBS samples that are extremely stable at different conditions for more than 100 days.
Collapse
|
Comparative Study |
13 |
30 |
4
|
Marques BLC, do Espírito-Santo MP, Marques VA, Miguel JC, da Silva EF, Villela-Nogueira CA, Lewis-Ximenez LL, Lampe E, Villar LM. Evaluation of dried blood spot samples for hepatitis C virus detection and quantification. J Clin Virol 2016; 82:139-144. [PMID: 27497191 DOI: 10.1016/j.jcv.2016.07.009] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2016] [Revised: 07/18/2016] [Accepted: 07/19/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Dried blood spots (DBS) could be an excellent alternative for HCV diagnosis, since it is less invasive and can be stored and transported without refrigeration. OBJECTIVES The aim of this study was to optimize quantitative and qualitative methods for HCV detection in DBS. STUDY DESIGN DBS and serum samples were collected from 99 subjects (59 anti-HCV/HCV RNA positive and 40 seronegative samples). Seven extraction methods and different PCR parameters were evaluated in DBS samples in the quantitative RT-PCR (qRT-PCR) developed to amplify the 5' noncoding region of HCV. A qualitative PCR for amplification of NS5B region of HCV was also valued and the nested-PCR sequenced. RESULTS The qRT-PCR showed good correlation to commercial assay for HCV viral measurement in serum. To quantify HCV RNA in DBS, it was necessary to increase reverse transcriptase and cDNA concentration. HCV RNA quantification in DBS demonstrated sensitivity of 65.9%, 100% of specificity and kappa statistic of 0.65. The median viral load of DBS samples was 5.38 log10 copies/ml (minimum value=1.76 and maximum value=10.48 log10 copies/ml). HCV RNA was detected in NS5B regions and nucleotide sequences obtained in 43 serum and 11 DBS samples. The presence of the same subtype was observed in paired serum and DBS samples. CONCLUSIONS In this study, it was possible to demonstrate that, despite the low sensitivity, the optimized protocol was able to determine the viral load, as well as, the infecting HCV genotype, validating the usefulness of DBS for viral load determination and molecular epidemiology studies of HCV.
Collapse
|
Evaluation Study |
9 |
17 |
5
|
Cruz HM, Marques VA, Villela-Nogueira CA, do Ó KMR, Lewis-Ximenez LL, Lampe E, Villar LM. An evaluation of different saliva collection methods for detection of antibodies against hepatitis C virus (anti-HCV). J Oral Pathol Med 2012; 41:793-800. [PMID: 22690929 DOI: 10.1111/j.1600-0714.2012.01176.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Saliva samples can be used as an alternative fluid for against hepatitis C virus (anti-HCV) detection owing to the ease of collection and excellent acceptability. This study was conducted to optimize a commercial enzyme immunoassay (EIA) to detect anti-HCV in saliva samples. METHODS Ninety-six individuals donated paired serum and saliva samples that were obtained, using a commercial device (Salivette) and spitting into a sterile container. Initially, elution buffer for the Salivette samples, sample volume, incubation time and temperature, and two different anti-HCV EIAs were evaluated. Using the optimized assay, three methods for cut-off calculation were also evaluated. RESULTS A 20-fold increase in the sample volume for both collection methods was needed. Moreover, the Radim assay was the most appropriate assay for anti-HCV detection in saliva samples, and the quality parameters were increased when a ROC curve was used to determine the cut-off value. Using this optimized assay, the sensitivities, specificities, accuracies, positive and negative predictive values were above 90% for saliva obtained using both the Salivette and spitting methods. Using this assay, discordant false-negative results were obtained for only two Salivette samples and five spitting samples. The concordance kappa was 93% for the Salivette method and 86.1% for the spitting method, demonstrating excellent performance. CONCLUSIONS Saliva samples obtained for both methods can be employed for anti-HCV detection among HCV-infected or HCV-suspected cases, but several modifications must be performed on commercial EIAs to obtain good results. Moreover, samples obtained with commercial devices are more appropriate for anti-HCV detection in saliva samples.
Collapse
|
Comparative Study |
13 |
14 |
6
|
Barbosa JR, Colares JKB, Flores GL, Cortes VF, Miguel JC, Portilho MM, Marques VA, Potsch DV, Brandão-Mello CE, Amendola-Pires M, Pilotto JH, Lima DM, Lampe E, Villar LM. Performance of rapid diagnostic tests for detection of Hepatitis B and C markers in HIV infected patients. J Virol Methods 2017; 248:244-249. [PMID: 28782578 DOI: 10.1016/j.jviromet.2017.08.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2017] [Revised: 07/30/2017] [Accepted: 08/03/2017] [Indexed: 02/07/2023]
Abstract
There is little information describing the influence of HIV infection upon the performance of rapid diagnostic tests (RDTs) for hepatitis B and C virus diagnosis. This study aims to evaluate the performance of RDTs for HBsAg and anti-HCV detection among HIV-infected individuals. A total of 362 HIV infected individuals were recruited from clinics between January 2013 to November 2014 in the southeast and northeast of Brazil. HBsAg and anti-HCV were detected using commercial EIAs and four RDTs: HBV (Vikia HBsAg® and Wama Imuno-Rapido HBV®) and HCV (Bioeasy Teste Rápido HCV® and Wama Imuno-Rapido HCV®). Reactive HBsAg and anti-HCV serum samples were tested for HBV DNA and HCV RNA. Sensitivity, specificity and kappa statistic were determined. Using EIA, HBsAg and anti-HCV were detected in 14 (3.9%) and 37 (10.2%) serum samples respectively. Using serum only, HBsAg RDTs demonstrated sensitivities and specificities above 92.0% and Kappa values above 89.0%. Anti-HCV RDTs demonstrated sensitivity and specificities above 82.0% and Kappa higher than 89.0%. Using whole blood samples, Vikia HBsAg® and Wama Imuno-Rapido HCV® showed sensitivity and specificity above 99.0% with Kappa of 66.4% and 100%, respectively. HIV viral load was higher among discordant results for anti-HCV RDT. RDTs demonstrated good performance in HIV infected individuals showing the usefulness of assays in this population.
Collapse
|
Journal Article |
8 |
14 |
7
|
Portilho MM, Mendonça A, Marques VA, Nabuco LC, Villela-Nogueira CA, Ivantes C, Lewis-Ximenez LL, Lampe E, Villar LM. Comparison of oral fluid collection methods for the molecular detection of hepatitis B virus. Oral Dis 2017; 23:1072-1079. [PMID: 28544047 DOI: 10.1111/odi.12692] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Revised: 04/09/2017] [Accepted: 05/11/2017] [Indexed: 12/14/2022]
Abstract
BACKGROUND This study aims to compare the efficiency of four oral fluid collection methods (Salivette, FTA Card, spitting and DNA-Sal) to detect HBV DNA by qualitative PCR. MATERIALS AND METHODS Seventy-four individuals (32 HBV reactive and 42 with no HBV markers) donated serum and oral fluid. In-house qualitative PCR to detect HBV was used for both samples and commercial quantitative PCR for serum. RESULTS HBV DNA was detected in all serum samples from HBV-infected individuals, and it was not detected in control group. HBV DNA from HBV group was detected in 17 samples collected with Salivette device, 16 samples collected by FTA Card device, 16 samples collected from spitting and 13 samples collected by DNA-Sal device. Samples that corresponded to a higher viral load in their paired serum sample could be detected using all oral fluid collection methods, but Salivette collection device yielded the largest numbers of positive samples and had a wide range of viral load that was detected. CONCLUSION It was possible to detect HBV DNA using all devices tested, but higher number of positive samples was observed when samples were collected using Salivette device, which shows high concordance to viral load observed in the paired serum samples.
Collapse
|
Comparative Study |
8 |
11 |
8
|
Barbosa JR, Cortes VF, Portilho MM, Miguel JC, Marques VA, Bezerra CS, de Souza NV, Lima DM, Colares JKB, Lewis-Ximenez LL, Lampe E, Villar LM. Performance of point of care assays for hepatitis B and C viruses in chronic kidney disease patients. J Clin Pathol 2018; 71:879-884. [PMID: 29730611 DOI: 10.1136/jclinpath-2018-205024] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Revised: 04/11/2018] [Accepted: 04/13/2018] [Indexed: 12/17/2022]
Abstract
AIMS Point of care testing (POCT) has been used for hepatitis B and C diagnosis in general population, but little is known about the influence of clinical conditions in the accuracy of these assays. This study aims to evaluate the performance of POCTs for detection of hepatitis B virus surface antigen (HBsAg) and antibodies to Hepatitis C Virus (anti-HCV) in Chronic Kidney Disease (CKD) patients. METHODS A total of 286 subjects were included in this study. HBsAg and anti-HCV were detected using commercial EIAs and four POCTs: HBsAg (WAMA Imuno-Rápido HBsAg and VIKIA HBsAg) and anti-HCV (DOLES HCV teste rápido and WAMA Imuno-Rápido anti-HCV) in serum and whole blood. RESULTS Using EIA, HBsAg and anti-HCV prevalence was 4.5% and 16.1% in CKD patients. HBsAg and anti-HCV POCTs had sensitivities from 92.3% to 100% and 84.8% to 89.1% while specificities were 99.3% to 100% and 99.2% to 99.6%, respectively. POCT using serum samples performed well compared with whole blood samples and true positive samples of POCTs had high optical density to cut-off (OD/CO) values compared with EIA. CONCLUSIONS This study demonstrates good performance of HBsAg and anti-HCV POCTs in CKD patients, especially in serum samples indicating low interference of this disease in the performance of these assays. POCTs could be an important tool for HBV and HCV screening in high-risk populations.
Collapse
|
Journal Article |
7 |
11 |
9
|
Sadio A, Peixoto P, Cancela E, Castanheira A, Marques V, Ministro P, Silva A, Caldas A. Intramural hematoma: a rare complication of endoscopic injection therapy for bleeding peptic ulcers. Endoscopy 2011; 43 Suppl 2 UCTN:E141-2. [PMID: 21425016 DOI: 10.1055/s-0029-1214927] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
Case Reports |
14 |
11 |
10
|
Villar LM, Geloneze B, Vasques ACJ, Pires MLE, Miguel JC, da Silva EF, Marques VA, Scalioni LDP, Lampe E. Prevalence of hepatitis B and hepatitis C among diabetes mellitus type 2 individuals. PLoS One 2019; 14:e0211193. [PMID: 30817756 PMCID: PMC6394929 DOI: 10.1371/journal.pone.0211193] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2018] [Accepted: 01/08/2019] [Indexed: 02/06/2023] Open
Abstract
Diabetes mellitus type 2 (DM2) patients have higher risk to be infected with parenterally transmitted viruses, like hepatitis B or C virus. This study aims to determine HBV and HCV infection prevalence in DM2 patients from Northeast and Southeast Brazil. A total of 537 DM2 patients were included, 194 (36.12%) males and 343 (63.87%) females, with mean age of 57.13±11.49 years. HBV and HCV markers were determined using serological and molecular analysis, and risk factors were evaluated in a subgroup from Southeast (n = 84). Two HBV acute (HBsAg+/anti-HBc -) and one HBV chronic case (HBsAg+/anti-HBc+) were found. Six individuals (1.1%) were isolated anti-HBc, 37 (6.9%) had HBV infection resolved (anti-HBc+/anti-HBs+), 40 (7.4%) were considered HBV vaccinated (anti-HBc-/anti-HBs+). Thirteen patients (2.42%) had anti-HCV and 7 of them were HCV RNA+. In the subgroup, anti-HBc positivity was associated to age and anti-HCV positivity was associated to age, time of diabetes diagnosis, total bilirubin, indirect bilirubin, alkaline phosphatase at bivariate analysis, but none of them was statistically significant at multivariate analysis. As conclusion, low prevalence of HBV and high prevalence HCV was found in DM2 patients.
Collapse
|
Research Support, Non-U.S. Gov't |
6 |
11 |
11
|
Flores GL, Cruz HM, Marques VA, Villela-Nogueira CA, Potsch DV, May SB, Brandão-Mello CE, Pires MMA, Pilotto JH, Pollo-Flores P, Esberard EBC, Ivantes C, Lewis-Ximenez LL, Lampe E, Villar LM. Performance of ANTI-HCV testing in dried blood spots and saliva according to HIV status. J Med Virol 2017; 89:1435-1441. [PMID: 28165155 DOI: 10.1002/jmv.24777] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 12/19/2016] [Accepted: 01/18/2017] [Indexed: 12/15/2022]
Abstract
The use of saliva and dried blood spots (DBS) could increase access to HCV diagnosis for high-risk populations, such as HIV-infected individuals, but the performance of these assays has not been well established in this group. This study aims to evaluate HIV status, particularly TCD4+ cell count and viral load, in the performance of anti-HCV testing using DBS and saliva. A total of 961 individuals classified as HCV+, HIV+, or HIV/HCV+, as well as negative controls, donated serum, DBS, and saliva samples for anti-HCV testing using a commercial enzyme immunoassay. Sample volume was modified for DBS and saliva, and an ROC curve was used for cut-off determination in saliva. Anti-HCV sensitivities were greater than 93% using DBS and saliva in the HCV+ group, while they were 83.3% and 95.6% for HCV/HIV+ individuals for DBS and saliva assays, respectively. Specificity varied from 91.7% to 100% using saliva and DBS in HIV monoinfected and control subjects. When only anti-HCV/HCV RNA+ serum samples, that is, true positives, were considered, the sensitivities were 98.3% and 100% for DBS and saliva, respectively, in the HCV+ group and 91.6% and 94.8% for DBS and saliva, respectively, in the HIV/HCV+ group. High absorbance values were observed among those presenting with HCV RNA in serum and low HIV viral load (less than 50 copies/mL). In conclusion, DBS and saliva samples could be used for anti-HCV detection, particularly to identify active HCV cases, but low sensitivity was observed for anti-HCV testing using DBS in the HIV/HCV+ group.
Collapse
|
Comparative Study |
8 |
11 |
12
|
Villar LM, da Costa VD, Marques BCL, da Silva LL, Santos AC, Mendonça ACDF, Marques VA, do Nascimento GP, Lewis-Ximenez LL, de Paula VS. USEFULNESS OF SALIVA SAMPLES FOR DETECTING SARS-CoV-2 RNA AMONG LIVER DISEASE PATIENTS. J Infect 2020; 82:e4-e5. [PMID: 32711040 PMCID: PMC7375959 DOI: 10.1016/j.jinf.2020.07.017] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 07/18/2020] [Indexed: 02/05/2023]
|
Letter |
5 |
10 |
13
|
Melo WD, Prudencio LA, Kusnir CE, Pereira AL, Marques V, Vieira MC, de Paola AA. [Angiography of the coronary venous system. Use in clinical electrophysiology]. Arq Bras Cardiol 1998; 70:409-13. [PMID: 9713083 DOI: 10.1590/s0066-782x1998000600006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
PURPOSE To study the angiographic anatomy of human coronary veins and the possibility of epicardial venous mapping through microelectrode catheters. METHODS We evaluated 30 patients with sustained ventricular tachycardia using a catheter which provided occlusion of the coronary sinus ostium during venous angiography. They were 25 males, 5 females, ages ranging from 24 to 76 years (mean = 52.7). The veins were studied according to their number, caliber and distribution in the anterior and posterior wall of the left ventricle. RESULTS Coronary sinus was catheterized in all patients. No discomfort or complication were observed. The number of veins from posterior wall of the left ventricle was 3.1 and anterior wall, 1.9, p < 0.05. The caliber of the coronary veins were: anterior interventricular vein (distal segment = 1.19 +/- 0.22 mm, middle segment = 1.65 +/- 0.35 mm), posterior interventricular vein (distal segment = 1.83 +/- 0.47 mm, middle segment = 2.00 +/- 0.52 mm), left posterior vein (distal segment = 1.45 +/- 0.25 mm, middle segment = 2.49 +/- 0.92 mm); p < 0.05. CONCLUSION The balloon occlusion technique for coronary venous angiography is feasible and safe. The number and the caliber (distal and middle) of the veins from the posterior wall of the left ventricle were significantly greater than those from the anterior wall. Anatomic conditions for venous epicardial mapping are more adequate in the posterior wall of the left ventricle.
Collapse
|
English Abstract |
27 |
5 |
14
|
Cruz HM, Miguel Cruz JC, Da Silva EF, Portilho MM, Marques VA, Lewis-Ximenez LL, Lampe E, Villar LM. Comparison of the performance of enzyme immunoassays for hepatitis B and C detection in dried blood spot. J Immunoassay Immunochem 2018; 39:228-233. [PMID: 29733758 DOI: 10.1080/15321819.2018.1470095] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Dried blood spots (DBSs) could be an alternative to serum for hepatitis B virus (HBV) and hepatitis C virus (HCV) diagnosis. This study aims to evaluate two enzyme immunoassays (EIAs) for HBsAg and anti-HCV detection using DBS. Serum was tested using commercial EIA. DBS was tested using optimized EIA developed for serum and commercial EIA developed for DBS (Imunoscreen). Concordances between DBS and serum samples for both markers and EIAs were higher than 97%. Both EIAs demonstrated good performance for HBsAg and anti-HCV detection using DBS, and these methods could be used unchangeably increasing the access for HBV and HCV diagnosis.
Collapse
|
Journal Article |
7 |
5 |
15
|
Tavares da Silva E, Oliveira R, Castelo D, Marques V, Sousa V, Moreira P, Simões P, Bastos CA, Figueiredo A, Mota A. Pretransplant biopsy in expanded criteria donors: do we really need it? Transplant Proc 2015; 46:3330-4. [PMID: 25498046 DOI: 10.1016/j.transproceed.2014.10.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
INTRODUCTION Renal transplantation is the best treatment for end-stage renal disease, including when using expanded criteria donors (ECD) kidneys. However, these suboptimal kidneys should be evaluated rigorously to meet their usefulness. Opinions differ about the best way to evaluate them. MATERIALS AND METHODS We retrospectively reviewed kidneys from ECD harvested by a single academic institution between January 2008 and September 2013. Needle biopsies were performed at the time of the harvest when considered relevant by the transplant team. Two pathologists where responsible for their analysis; the Remuzzi classification has been used in all cases. RESULTS We evaluated 560 ECD kidneys. Biopsies were made in 197 (35.2%) organs, 20 of which were considered not usable and 36 good only for double transplantation. Sixty-three kidneys (11.3%) were discarded by the transplant team based on the biopsy result and clinical criteria. Donors who underwent a biopsy were older (P < .001) and had a worse glomerular filtration rate (GFR; P = .001). Comparing donors approved and rejected by the biopsy, the rejected donors were heavier (P = .003) and had a lower GFR (P = .002). Cold ischemia time was longer for the biopsy group (P < .001). Regarding graft function, the biopsy overall score correlated with the transplant outcome in the short and long term. Separately, glomeruli and interstitium scores were correlated with recipient's GFR in the earlier periods (3 months; P = .025 and .037), and the arteries and tubules correlated with GFR in the longer term (at 3 years P = .004 and .010). CONCLUSION The decision on the usability of ECD grafts is complex. At our center, we chose a mixed approach based on donor risk. Low-risk ECD do not require biopsy. In more complex situations, especially older donors or those with a lower GFR, prompted a pretransplant biopsy. The biopsy results proved to be useful as they relate to subsequent transplant outcomes, thereby allowing us to exclude grafts whose function would most probably be less than optimal.
Collapse
|
Journal Article |
10 |
3 |
16
|
Portilho MM, Bezerra CS, Mendonça ACDF, Marques VA, Nabuco LC, Villela-Nogueira CA, Ivantes CAP, Lewis-Ximenez LL, do Lago BV, Villar LM. Applicability of oral fluid samples for tracking hepatitis B virus mutations, genotyping, and phylogenetic analysis. Arch Virol 2021; 166:2435-2442. [PMID: 34146173 DOI: 10.1007/s00705-021-05122-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 04/14/2021] [Indexed: 10/21/2022]
Abstract
Little is known about the usefulness of saliva samples for hepatitis B virus (HBV) genotyping and mutation analysis. The aim of this study was to evaluate the usefulness of oral fluid samples to determine HBV genotype distribution, S/polymerase mutations, and HBV subpopulation diversity among chronically HBV-infected individuals. Serum and oral fluid samples were obtained from 18 individuals for PCR and nucleotide sequencing of the HBV surface antigen gene. Biochemical analysis of liver enzymes (ALT, AST, GGT) and HBV, HCV, and HIV serological tests were also performed. All serum samples were HBsAg (+), anti-HBc (+), and anti-HBs (-); 55.6% were HBeAg (+)/anti-HBe (-), and 11.1% were anti-HIV (+). The mean HBV DNA viral load was 6.1 ± 2.3 log IU/mL. The HBV genotype distribution was as follows: A, 72.2%; D, 11.1%; E, 5.6%; F, 11.1%. A concordance of 100% in genotype classification and 99.8% in sequence similarity between paired oral fluid and serum samples was observed. HBsAg mutations were detected in all samples, but no resistance mutations were found in the polymerase gene. This study demonstrates that oral fluid samples can be used reliably for tracking HBV mutations, genotyping, and phylogenetic analysis. This could be important for molecular epidemiology studies with hard-to-reach populations.
Collapse
|
|
4 |
2 |
17
|
Villar LM, Caldas GC, Scalioni LDP, Miguel JC, da Silva EF, Marques VA, Villela-Nogueira CA, Lewis-Ximenez LL, Lampe E. High prevalence of insulin resistance among Brazilian chronic hepatitis C patients. ARCHIVES OF ENDOCRINOLOGY AND METABOLISM 2017; 61:628-632. [PMID: 29412389 PMCID: PMC10522051 DOI: 10.1590/2359-3997000000315] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2016] [Accepted: 07/31/2017] [Indexed: 11/22/2022]
Abstract
OBJECTIVE This study aims to estimate the prevalence of insulin resistance (IR) among chronic hepatitis C (CHC) patients and their related laboratory and demographic data. SUBJECTS AND METHODS In this study, non-diabetic CHC patients referred to Viral Hepatitis Ambulatories from Rio de Janeiro (Brazil) donated blood samples. Insulin was measured using a chemiluminescence immunoassay. IR was determined by HOMA-IR, where HOMA-IR > 2 was defined as IR. RESULTS A total of 214 CHC patients were recruited (123 females aged 53.6 years ± 10.9 years). IR was present in 133 patients (62.1%) and was associated in bivariate analysis to higher mean values of age (p = 0.040), triglycerides (p = 0.032), glucose (p = 0.000), insulin (p = 0.000), waist circumference (p = 0.001), and body mass index (p = 0.007); however, none of these variables were significant in the multivariate analysis. CONCLUSIONS The high prevalence of IR was observed among CHC patients, and there was no difference in clinical or laboratory parameters when both groups were compared in the multivariate analysis. This high IR prevalence could lead to a high risk for development of cardiovascular disease and metabolic disorders.
Collapse
|
brief-report |
8 |
1 |
18
|
|
Case Reports |
27 |
1 |
19
|
Scalioni LDP, da Silva AP, Miguel JC, Espírito Santo MPD, Marques VA, Brandão-Mello CE, Villela-Nogueira CA, Lewis-Ximenez LL, Lampe E, Villar LM. Lack of Association between Hepatitis C Virus core Gene Variation 70/91aa and Insulin Resistance. Int J Mol Sci 2017; 18:1444. [PMID: 28753979 PMCID: PMC5535935 DOI: 10.3390/ijms18071444] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Revised: 05/17/2017] [Accepted: 05/24/2017] [Indexed: 01/08/2023] Open
Abstract
The role of hepatitis C virus (HCV) in insulin resistance (IR) is not fully understood. The aim of this study was to determine the impact of amino acid (aa) substitutions in the core region of HCV according to IR and to identify clinical and laboratory associations. Ninety-two treatment-naive HCV patients were recruited to determine laboratory data and blood cell count. IR was determined using Homeostasis Model Assessment (HOMA) index where IR was defined as HOMA ≥2. HCV RNA load and genotype were determined by Abbott Real time HCV. HCV core region was determined by direct nucleotide sequencing. Bivariate analysis was conducted using HOMA IR ≥2 as a dependent factor. IR prevalence was 43.5% (n = 40), vitamin D sufficiency was found in 76.1% (n = 70) and 72.8% (n = 67) had advanced liver fibrosis. In the bivariate analyses, elevated values of γGT (p = 0.024) and fibrosis staging (p = 0.004) were associated with IR, but IR was not related to core mutations. The presence of glutamine in position 70 was associated with low vitamin D concentration (p = 0.005). In the multivariate analysis, no variable was independently associated with HOMA-IR. In conclusion, lack of association between IR and HCV core mutations in positions 70 and 91 suggests that genetic variability of this region has little impact on IR.
Collapse
|
research-article |
8 |
1 |
20
|
Mackmill L, Marques V, Krewer D, Medeiros L, Caldeira C. Desenvolvimento de um aplicativo pedagógico como tecnologia de informação e comunicação móvel para a disciplina de desenho técnico. REVISTA THEMA 2017. [DOI: 10.15536/thema.14.2017.212-224.390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
|
8 |
|
21
|
Moreda KF, Cecagno D, Weykamp JM, Moura PMM, Biana CB, Porto AR, Marques V. Processo de tomada de decisão no trabalho em uma maternidade: vivências de enfermeiros. REVISTA ENFERMAGEM ATUAL IN DERME 2019. [DOI: 10.31011/reaid-2019-v.87-n.25-art.216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Objetivo: conhecer as vivências de enfermeiros com o processo de tomada de decisão no trabalho em uma maternidade. Método: tratou-se de uma pesquisa qualitativa, na qual foram entrevistadas, em 2017, 18 enfermeiras de uma maternidade no sul doBrasil e os dados tratados sob análise temática. Resultados: algumas enfermeiras entenderam a tomada de decisões enquantoum processo contínuo e dinâmico, a depender de outros profissionais. O trabalho em equipe e a experiência foram apontadosenquanto facilitadores do processo e a principal barreira, o poder de decisão do enfermeiro estar subjugado pela soberaniahierárquica médica. O investimento em conhecimento técnico-científico, comunicação efetiva, relacionamento interpessoal saudável e trabalho em equipe multiprofissional foram assinalados como potentes para melhoria da tomada de decisões. Conclusão:Os enfermeiros ainda não se sentem preparados e seguros a partir de sua formação acadêmica para tomar decisões e para otrabalho multiprofissional, requerendo maiores investimentos na educação em serviço.Descritores: Tomada de decisões; Obstetrícia; Enfermeiras e enfermeiros; Ambiente de trabalho.Objective: to know the experiences of nurses with the process of decision making at work in a maternity hospital. Method:it is a qualitative research, including 18 nurses from a maternity hospital in southern Brazil, interviewed in 2017. The data wasanalyzed under thematic analysis. Results: nurses understood decision making as a continuous and dynamic process, dependingon other professionals. Teamwork and experience were identified as facilitators of the process, whereas the hierarchical medicalsovereignty overpowering nurses’ decision-making was the main barrier of process. Investment in technical-scientific knowledge,effective communication, healthy interpersonal relationship and multiprofessional teamwork were pointed out as potent devicesfor better decision-making. Conclusion: nurses still do not feel prepared and confident from their academic education to makedecisions and work multiprofessional, requiring greater investments in professional education.Keywords: Decision making; Obstetrics, Nurses, Work environment.
Collapse
|
|
6 |
|
22
|
Luzes B, Marques V, Resende A, Rodrigues R. [Right infective endocarditis. Presentation of 3 clinical cases and review of the literature]. Rev Port Cardiol 1992; 11:1081-7. [PMID: 1290652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
|
Case Reports |
33 |
|
23
|
Lago BV, Portilho MM, Mello VM, De Sousa PSF, Angelice GP, Marques BCL, da Silva Andrade LT, Marques VA, Lewis-Ximenez LL, Mello FCDA, Villar LM. Genetic variability of hepatitis B virus in acute and in different phases of chronic infection in Brazil. Sci Rep 2024; 14:10742. [PMID: 38730249 PMCID: PMC11087654 DOI: 10.1038/s41598-024-60900-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 04/29/2024] [Indexed: 05/12/2024] Open
Abstract
The selection pressure imposed by the host immune system impacts on hepatitis B virus (HBV) variability. This study evaluates HBV genetic diversity, nucleos(t)ide analogs resistance and HBsAg escape mutations in HBV patients under distinct selective pressures. One hundred and thirteen individuals in different phases of HBV infection were included: 13 HBeAg-positive chronic infection, 9 HBeAg-positive chronic hepatitis, 47 HBeAg-negative chronic infection (ENI), 29 HBeAg-negative chronic hepatitis (ENH) and 15 acute infected individuals. Samples were PCR amplified, sequenced and genetically analyzed for the overlapping POL/S genes. Most HBV carriers presented genotype A (84/113; 74.3%), subgenotype A1 (67/84; 79.7%), irrespective of group, followed by genotypes D (20/113; 17.7%), F (8/113; 7.1%) and E (1/113; 0.9%). Clinically relevant mutations in polymerase (tL180M/M204V) and in the Major Hydrophilic Region of HBsAg (sY100C, T118A/M, sM133T, sD144A and sG145R) were observed. Our findings, however, indicated that most polymorphic sites were located in the cytosolic loops (CYL1-2) and transmembrane domain 4 (TMD4) of HBsAg. Lower viral loads and higher HBV genetic diversity were observed in ENI and ENH groups (p < 0.001), suggesting that these groups are subjected to a higher selective pressure. Our results provide information on the molecular characteristics of HBV in a diverse clinical setting, and may guide future studies on the balance of HBV quasispecies at different stages of infection.
Collapse
|
research-article |
1 |
|
24
|
Marques V. [Exophthalmia--its neurologic and neurosurgical aspects]. JORNAL DA SOCIEDADE DAS CIENCIAS MEDICAS DE LISBOA 1965; 129:245-50. [PMID: 5837013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
|
60 |
|
25
|
Espírito-Santo MPD, Brandão-Mello CE, Marques VA, Lampe E, Almeida AJD. Analysis of hepatitis C virus (HCV) RNA load in platelets of HCV-monoinfected patients receiving antiviral therapy. Ann Hepatol 2013; 12:373-9. [PMID: 23619253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
INTRODUCTION Detection of hepatitis C virus (HCV) has been reported in extrahepatic sites such as peripheral blood mononuclear cells and platelets. Quantitation of HCV-RNA in platelets from patients under antiviral therapy has not been reported. MATERIAL AND METHODS HCV-RNA levels in paired serum and platelet samples of 17 chronically HCV-infected patients were determined at baseline, week 12, end-of-treatment, and 24 weeks after completion of treatment with pegylated interferon plus ribavirin. Quantitation of HCVRNA load was performed using COBAS® TaqMan® HCV Test v 2.0 (lower limit of detection, 25 IU/mL). The cohort predominantly consisted of female (59%) with a mean age of 50.7 ± 10.0 years. RESULTS Measurements of HCV-RNA in relation to different timepoints of therapy revealed baseline viral load was most frequently detected in higher levels in serum than in platelets (5.6 x 104 IU/mL vs. 379.0 IU/mL; p = 0.0002), a trend also demonstrated in most samples throughout the study. HCV-RNA was also found at low levels (< 25.0-314.0 UI/mL) persistently in platelets of three patients who have lost detectable HCV-RNA in serum during antiviral therapy, resulting in virological relapse. CONCLUSION HCV-RNA levels are most frequently detected in higher levels in serum than in platelets, independent of timepoint of antiviral therapy. Further studies with an increase in size of the samples are needed to better evaluate whether or not patients who presented HCV-RNA at low levels in platelets after having lost detectable HCV-RNA in serum during antiviral therapy are at increased risk of relapse of HCV infection during follow-up evaluation.
Collapse
|
Clinical Trial |
12 |
|