1
|
Enumeration of Total Bacteria and Coliforms in Milk by Dry Rehydratable Film Methods: Collaborative Study. J AOAC Int 2020. [DOI: 10.1093/jaoac/69.3.527] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
Eleven laboratories participated in a collaborative study to compare the dry rehydratable film (Petrifilm® SM and Petrifilm® VRB) methods, respectively, to the standard plate count (SPC) and violet red bile agar (VRBA) standard methods for estimation of total bacteria and coliform counts in raw and homogenized pasteurized milk. Each laboratory analyzed 16 samples (8 different samples in blind duplicate) for total count by both the SPC and Petrifilm SM methods. A second set of 16 samples was analyzed by the VRBA and Petrifilm VRB methods. The repeatability standard deviations (the square root of the between-replicates variance) of the SPC, Petrifilm SM, VRBA, and Petrifilm VRB methods were 0.0S104, 0.0444, 0.14606, and 0.13806, respectively; the reproducibility standard deviations were 0.7197, C.06380, 0.15326, and 0.13806, respectively. The difference between the mean Iog10 SPC and the mean logio Petrifilm SM results was 0.027. For the VRBA and Petrifilm VRB methods, the mean log10 difference was 0.013. These results generally indicate the suitability of the dry rehydratable film methods as alternatives to the SPC and VRBA methods for milk samples. The methods have been adopted official first action.
Collapse
|
2
|
Automated Technique for Sampling Milk from Farm Bulk Tanks: Collaborative Study. J AOAC Int 1993. [DOI: 10.1093/jaoac/76.2.297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Abstract
An automated, in-line, mechanical technique for sampling milk from farm bulk tanks was evaluated in a collaborative study. The automated sampling device, which is mounted on the milk intake line, contains an electronically controlled peristaltic pump. The device takes a representative sample of the entire volume pumped through the system. Samples taken can be analyzed for both composition and microbiological quality. The study was performed in 3 phases. In the first 2 phases, samples taken by manual and automated methods were compared in analyses for somatic cell count, antibiotics, fat, protein, lactose, and solids-not-fat. The third phase, using a modified procedure, was designed to compare sampling methods in analyses for total bacteria count (standard plate count), psychrotrophic bacteria count, and coliform count. Evaluation of the data by a nested ANOVA indicated no difference between results for samples taken by the automated and manual methods (P = 0.05) in Phases 1 and 2, irrespective of whether the bulk milk was agitated before sampling. By introducing a sanitizing step between farms in Phase 3, the automated method also provided samples comparable with those taken manually for microbial analyses. The automated method has been adopted first action by AOAC International.
Collapse
|
3
|
Automated technique for sampling milk from farm bulk tanks: collaborative study. J AOAC Int 1993; 76:297-305. [PMID: 8471856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
An automated, in-line, mechanical technique for sampling milk from farm bulk tanks was evaluated in a collaborative study. The automated sampling device, which is mounted on the milk intake line, contains an electronically controlled peristaltic pump. The device takes a representative sample of the entire volume pumped through the system. Samples taken can be analyzed for both composition and microbiological quality. The study was performed in 3 phases. In the first 2 phases, samples taken by manual and automated methods were compared in analyses for somatic cell count, antibiotics, fat, protein, lactose, and solids-not-fat. The third phase, using a modified procedure, was designed to compare sampling methods in analyses for total bacteria count (standard plate count), psychrotrophic bacteria count, and coliform count. Evaluation of the data by a nested ANOVA indicated no difference between results for samples taken by the automated and manual methods (P = 0.05) in Phases 1 and 2, irrespective of whether the bulk milk was agitated before sampling. By introducing a sanitizing step between farms in Phase 3, the automated method also provided samples comparable with those taken manually for microbial analyses. The automated method has been adopted first action by AOAC International.
Collapse
|
4
|
Compositional and Selected Functional Properties of Whey Protein Concentrates and Lactose-Hydrolyzed Whey Protein Concentrates 1. J Food Prot 1986; 49:192-195. [PMID: 30959728 DOI: 10.4315/0362-028x-49.3.192] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Commercial whey protein concentrate (WPC) products, manufactured by ultrafiltration with and without lactose hydrolysis, were compared for proximate composition, mineral and trace mineral composition and for protein solubility and viscosity parameters. Protein concentration ranged from 30.5 to 52.7%, while ash content ranged from 5.9 to 12.0%. Extent of lactose hydrolysis in lactose-hydrolyzed WPCs was estimated at 60 to 75% of the initial lactose level. Protein solubility of 10% protein dispersions of the WPC samples ranged from 90 to 100% and was not affected by heating WPC dispersions at 65°C for 30 min or by increased centrifugation force in solubility determination from 40,000 × g to 100,000 × g. All WPC dispersions exhibited pseudoplastic flow behavior as indicated by flow behavior indices (n) of less than 1.0. WPC dispersions possessed a low viscosity as indicated by consistency index (k) data, and k values decreased slightly after heating. Lactose hydrolysis had no apparent effect on solubility or viscosity properties of the WPC dispersions. Alteration of electrophoretic mobility of polyacrylamide gel electrophoresis was observed for α-lactalbumin in lactose-hydrolyzed WPC samples.
Collapse
|
5
|
Abstract
Breastfeeding is a natural and worthy practice, encouraged and promoted by many health professionals. Under most conditions, breastmilk serves infant nutritional and immunological needs well. Nevertheless, there are risks engendered in the practice, one of the more serious of which centers on contamination of human milk with drugs, pesticides, and environmental contaminants. As a reminder of the fact and to highlight some recent research findings, this review is offered.
Collapse
|
6
|
|
7
|
Evaluation of the 3M Dry Medium Culture Plate (Petrifilm™ SM) Method for Determining Numbers of Bacteria in Raw Milk 1. J Food Prot 1984; 47:753-755. [PMID: 30934511 DOI: 10.4315/0362-028x-47.10.753] [Citation(s) in RCA: 34] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The 3M Company has developed a sample-ready system (Petrifilm ™ SM) for enumerating bacteria in milk and other food products. The testing unit consists of Standard Methods culture medium coated onto a base film and overlaid with a second film coated with a cold-water-soluble gelling agent and tetrazolium indicator dye. As such, the system is ready to accept samples of product. A pipette or 0.001-ml plate loop continuous pipetting syringe can be used for applying samples. In this study, both methods of sample addition were used and results compared with those of the Standard Plate Count (SPC) and standard Plate Loop (PL) methods for determining bacteria numbers in raw milk. In total, 108 samples were analyzed in duplicate by each of the four methods. The correlation coefficients (r) between the 3M-SPC and SPC, 3M-PL and PL, 3M-PL and SPC and PL and SPC were 0.946, 0.935, 0.941, and 0.974, respectively. Repeatability, as measured by mean log10 variance for duplicate determinations, was essentially the same for the four methods, and in all instances less than 0.005. The mean log10 differences between the SPC and 3M-SPC, and SPC and 3M-PL were, respectively, -0.177 and -0.168. The preceding statistical criteria suggest the Petrifilm™ SM method to be a suitable alternative to the SPC or the PL procedure.
Collapse
|
8
|
Quantitative estimates of beta-lactam residues in raw milk around a reference standard: collaborative study. JOURNAL - ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS 1982; 65:1407-1412. [PMID: 7174583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
A collaborative study was conducted to determine the reliability of a Bacillus stearothermophilus disc assay method for differentiating various concentrations of penicillin in raw milk. Participating laboratories tested 10 different samples (including one negative) in blind duplicate. Triplicate standards were alternated with triplicate unknowns around the periphery of each of 5 different plates. Zone diameters were measured and the difference in zone size of pairs of adjacent standard and unknown samples were analyzed by a paired t-test. Penicillin concentrations 0.003 IU/mL different from the reference concentrations were consistently distinguishable at a 95% confidence level. Such discriminatory power was determined to be possible with as few as 3 plates (9 replicates) per unknown. The method has been adopted official first action.
Collapse
|
9
|
Quantitative Estimates of Beta-Lactam Residues in Raw Milk Around a Reference Standard: Collaborative Study. J AOAC Int 1982. [DOI: 10.1093/jaoac/65.6.1407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
A collaborative study was conducted to determine the reliability of a Bacillus stearothermophilus disc assay method for differentiating various concentrations of penicillin in raw milk. Participating laboratories tested 10 different samples (including one negative) in blind duplicate. Triplicate standards were alternated with triplicate unknowns around the periphery of each of 5 different plates. Zone diameters were measured and the difference in zone size of pairs of adjacent standard and unknown samples were analyzed by a paired t-test. Penicillin concentrations 0.003 IU/mL different from the reference concentrations were consistently distinguishable at a 95% confidence level. Such discriminatory power was determined to be possible with as few as 3 plates (9 replicates) per unknown. The method has been adopted official first action.
Collapse
|
10
|
Abstract
Numerous methods have been developed to determine presence of antibiotics in raw milk. Until recently, major effort had been placed on qualitative considerations, and primarily for detecting presence of penicillin (beta-lactam) residues. Only one method, the Sarcina lutea Cylinder Plate (CP) procedure, has been modified to provide for quantitative estimates. The CP method is a rather long, tedious test, requiring considerable technical skill. Need for a simpler, faster quantitative method was apparent. This paper describes a method for making quantitative estimates of beta-lactam residues around a fixed reference standard. The method uses Bacillus stearothermophilus in a disc assay test. Quantitative estimates above or below the reference level of antibiotic are computed through a paired-t statistical analysis. The test can be completed within 3 h.
Collapse
|
11
|
Abstract
Over nine replicate trials, five methods for detecting antibiotic residues were evaluated for sensitivity to various levels of penicillin, erythromycin and chloramphenicol in milk. The methods included (a) the Charm test, (b) Delvotest P, (c) disc assay with Bacillus subtilis on whey agar, (d) B. subtilis on Antibiotic Medium #1 and (e) Difco disc assay method using Bacillus stearothermophilus var. calidolactis on PMI agar. Specific to penicillin only, the Charm test detected the antibiotic 100% of the time down to and including 0.01 unit/ml, dropping to 56% detectability at 0.0025 unit/ml. Delvotest P detected penicillin 100% of the time at 0.025 unit/ml, but at varying degrees of sensitivity through 0.0025 unit/ml, and with evidence of showing false-positive results. Methods (c), (d) and (e) detected penicillin at 0.05 unit/ml 78, 89 and 100% of the time, respectively. Methods (d) and (e) were generally more sensitive to erythromycin and chloramphenicol than either (b) or (c).
Collapse
|
12
|
Abstract
A study was made of the variation in herd milk composition and the interrelationship of various milk components as factors to be considered in milk pricing schemes, involving milkfat and/or other milk components. As measured by the coefficient of variability, fat was found to be the most variable component, followed by, in descending order of variability, protein, total solids, lactose, and solids-not-fat (SNF). Non-protein-nitrogen (NPN) level averaged 4.36 % of total nitrogen in 99 herd samples collected and analyzed in November, 1978. Coefficient of variation of NPN was 15.18. Thus NPN represents a significant factor in protein analysis where the Kjeldahl procedure is used as a reference standard. This fact lends weight to the desirability of basing milk purchase, if protein is involved, on "true" protein (total nitrogen minus non-protein-nitrogen) rather than total nitrogen.
Collapse
|
13
|
Repeatability and Accuracy of Dye-Binding and Infra-Red Methods for Analyzing Protein and Other Milk Components 1. J Food Prot 1980; 43:374-375. [PMID: 30822879 DOI: 10.4315/0362-028x-43.5.374] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Udy and Pro-Milk Mark II dye-binding methods and the Milko-Scan 104 infra-red device were evaluated for accuracy and repeatability in the analysis of protein in raw milk supplies. The infra-red device was also evaluated for accuracy in determination of milkfat, lactose and solids-not-fat, and was compared with the Milko-Tester for fat analysis. Repeatability of the three methods was, in all instances, less than 0.05% for protein. Standard deviation of accuracy (σy,x) for protein (total nitrogen × 6.38) for the Udy Analyzer, Pro-Milk, and Milko-Scan units was 0.063, 0.062, and 0.067, respectively. Standard deviation of accuracy of the Milko-Scan rated against Mojonnier and Milko-Tester methods for milkfat was, respectively, 0.054 and 0.050. Compared with liquid chromatography lactose determination and Mojonnier solids-not-fat determination, the Milko-Scan showed a standard deviation of accuracy of 0.083 and 0.073, respectively.
Collapse
|
14
|
Precision of the Pro-Milk Method in Routine Determination of Protein in Dairy Testing Laboratories 1. J Food Prot 1980; 43:52-53. [PMID: 30822918 DOI: 10.4315/0362-028x-43.1.52] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In a collaborative study of the Pro-Milk Mark II dye-binding method for determining protein in milk, repeatability (r) was found to be 0.053% protein, and reproducibility (R) 0.215% protein at the 95% confidence level. Standard deviations of these two measures of performance were 0.0188 and 0.0761, respectively. Repeatability was influenced by sampling error, mis-readings, equipment performance and routine control. Reproducibility was influenced by the same factors and, in addition, accuracy of calibration, with Kjeldahl as the reference method. Results of this study indicate the need to centralize laboratory calibration and to calibrate equipment over a wide range of protein levels.
Collapse
|
15
|
Comparison of the Automated with the Semi-Automatic Coulter Counter Method and the Direct Microscopic Somatic Cell Count (DMSCC) on Raw Milk Samples 1. J Food Prot 1979; 42:567-568. [PMID: 30812134 DOI: 10.4315/0362-028x-42.7.567] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The automatic Milk Cell Counter (MCC) and semi-automatic electronic cell counter (ESCC) of Coulter Electronics were compared with each other and with the direct microscopic cell count (DMSCC) on raw milk samples with various cell counts. The average DMSCC count on 241 samples of milk with Wisconsin Mastitis Test (WMT) results of 22 mm and higher was 55,000 cells/ml above the average MCC count when calibrated to a 4.4-μm minimum particle diameter. This difference is statistically significant at the 1% level. On 24 different raw milk samples of widely varying somatic cell count analyzed in replicate six times per sample, the standard deviations for replicate samples were 34,300, 34,900 and 136,000 for the MCC, ESCC and DMSCC, respectively. For these tests, the MCC had been calibrated to a 4.3-μm minimum particle diameter. The average difference between counts by the MCC and ESCC methods was only 6080/ml, but this was statistically significant at the 5% level. The average MCC count with the equipment set at 4.3-μm minimum particle diameter was 58,000 above the average DMSCC count.
Collapse
|
16
|
Abstract
A frozen concentrate of Lactobacillus acidophilus was used as inoculum for milk solids-not-fat (MSNF) reconstituted to 25 and 40% solids. Initial count of the two milks was 1.2 × 109 and 7.0 × 108 CFU/g of solids, respectively. Sublots of these two concentrates were spray-dried at 85-, 80-, and 75-C exit air temperature in a Coulter/Townley pilot dryer (vertical, venturi nozzle spray system). Survival of L. acidophilus was greatest at the lowest outlet air temperature investigated, and in the milk of lower solids content. At 75-C exit air temperature the count following drying was 2.6 × 107 per gram of solids at 40 percent solids, and 9.8 × 107 per gram of solids at 25% solids. Percent survival after 30 days storage under nitrogen at 4 C was 1.29 and 4.17, respectively, for the two solids levels.
Collapse
|
17
|
Abstract
The legal upper base for taking action in cases of water adulteration of milk is generally accepted as - 0.525°H. Henningson (2), in a study of 660 samples of milk known to contain no added water and representing 22 states in the U.S. and four Canadian provinces, found (at the 95% confidence limit) only 1% probability of a naturally-occurring milk sample falling above that level. Yet at a mean value of - 0.540°H, as noted in this same study, such base allows for 3% added water for the "average" dairy farm. The present study, made on samples without knowledge of their purity (lack of added water), tends to confirm this potential. At the same time it suggests the likelihood that, on a practical basis, a "working factor" set at some lower value could be useful to the dairy industry in coping with the problem of added water in milk.
Collapse
|
18
|
Comparative Evaluation of the Difco Disc Assay Method for Detecting Penicillin in Milk and Milk Products. J Food Prot 1978; 41:361-363. [PMID: 30795150 DOI: 10.4315/0362-028x-41.5.361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The Difco disc assay method to detect antibiotic residues was evaluated and compared with the Bacillus subtilis disc assay and the Sarcinia lutea cylinder plate methods. The Difco method, using both color change and zone of inhibition as indicator, was able to detect penicillin to levels as low as 0.002 units per ml. Of 5200 raw milk samples analyzed for presence of penicillin in a commercial laboratory, the B. subtilis disc assay method identified and confirmed as positive 12 samples (0.239%). The Difco disc assay method identified 61 samples as positive for inhibitor, of which 48 (0.92%) were confirmed as positive for penicillin. Of 37 of these latter samples, analyzed also by the S. lutea cylinder plate method, 29 (78.4%) yielded positive results. The Difco procedure was found effective as a test method for detecting penicillin in finished fluid milk products.
Collapse
|
19
|
Collaborative Study of the Coulter Counter-Chemical Method for Counting Somatic Cells in Raw Milk 1. J Food Prot 1977; 40:456-458. [PMID: 30731619 DOI: 10.4315/0362-028x-40.7.456] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Variation between laboratories for Electronic Somatic Cell Counting by the chemical method (ESCC) was evaluated by a collaborative study. Eight laboratories counted somatic cells in 12 milk samples (six replicated samples) by the ESCC method. The somatic cell count for the same milk samples was also evaluated by the Direct Microscopic Somatic Cell Counting procedure (DMSCC) as a comparison for the level of error. The standard deviation of the variation of logarithms of ESCC counts between laboratories was 0.04368. The standard deviation for the variation of logarithms of DMSCC counts between technicians was 0.08617. The corresponding value for the DMSCC analysis of the last set of federal split milk samples was 0.141. An earlier study of electronic counting by the centrifuge method showed a standard deviation of 0.0711.
Collapse
|