1
|
Barth RF, Vicente MGH, Harling OK, Kiger WS, Riley KJ, Binns PJ, Wagner FM, Suzuki M, Aihara T, Kato I, Kawabata S. Current status of boron neutron capture therapy of high grade gliomas and recurrent head and neck cancer. Radiat Oncol 2012; 7:146. [PMID: 22929110 PMCID: PMC3583064 DOI: 10.1186/1748-717x-7-146] [Citation(s) in RCA: 321] [Impact Index Per Article: 24.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2012] [Accepted: 07/23/2012] [Indexed: 11/25/2022] Open
Abstract
Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Clinical interest in BNCT has focused primarily on the treatment of high grade gliomas, recurrent cancers of the head and neck region and either primary or metastatic melanoma. Neutron sources for BNCT currently have been limited to specially modified nuclear reactors, which are or until the recent Japanese natural disaster, were available in Japan, the United States, Finland and several other European countries, Argentina and Taiwan. Accelerators producing epithermal neutron beams also could be used for BNCT and these are being developed in several countries. It is anticipated that the first Japanese accelerator will be available for therapeutic use in 2013. The major hurdle for the design and synthesis of boron delivery agents has been the requirement for selective tumor targeting to achieve boron concentrations in the range of 20 μg/g. This would be sufficient to deliver therapeutic doses of radiation with minimal normal tissue toxicity. Two boron drugs have been used clinically, a dihydroxyboryl derivative of phenylalanine, referred to as boronophenylalanine or “BPA”, and sodium borocaptate or “BSH” (Na2B12H11SH). In this report we will provide an overview of other boron delivery agents that currently are under evaluation, neutron sources in use or under development for BNCT, clinical dosimetry, treatment planning, and finally a summary of previous and on-going clinical studies for high grade gliomas and recurrent tumors of the head and neck region. Promising results have been obtained with both groups of patients but these outcomes must be more rigorously evaluated in larger, possibly randomized clinical trials. Finally, we will summarize the critical issues that must be addressed if BNCT is to become a more widely established clinical modality for the treatment of those malignancies for which there currently are no good treatment options.
Collapse
|
Review |
13 |
321 |
2
|
Goorley JT, Kiger WS, Zamenhof RG. Reference dosimetry calculations for neutron capture therapy with comparison of analytical and voxel models. Med Phys 2002; 29:145-56. [PMID: 11865986 DOI: 10.1118/1.1428758] [Citation(s) in RCA: 97] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
As clinical trials of Neutron Capture Therapy (NCT) are initiated in the U.S. and other countries, new treatment planning codes are being developed to calculate detailed dose distributions in patient-specific models. The thorough evaluation and comparison of treatment planning codes is a critical step toward the eventual standardization of dosimetry, which, in turn, is an essential element for the rational comparison of clinical results from different institutions. In this paper we report development of a reference suite of computational test problems for NCT dosimetry and discuss common issues encountered in these calculations to facilitate quantitative evaluations and comparisons of NCT treatment planning codes. Specifically, detailed depth-kerma rate curves were calculated using the Monte Carlo radiation transport code MCNP4B for four different representations of the modified Snyder head phantom, an analytic, multishell, ellipsoidal model, and voxel representations of this model with cubic voxel sizes of 16, 8, and 4 mm. Monoenergetic and monodirectional beams of 0.0253 eV, 1, 2, 10, 100, and 1000 keV neutrons, and 0.2, 0.5, 1, 2, 5, and 10 MeV photons were individually simulated to calculate kerma rates to a statistical uncertainty of <1% (1 std. dev.) in the center of the head model. In addition, a "generic" epithermal neutron beam with a broad neutron spectrum, similar to epithermal beams currently used or proposed for NCT clinical trials, was computed for all models. The thermal neutron, fast neutron, and photon kerma rates calculated with the 4 and 8 mm voxel models were within 2% and 4%, respectively, of those calculated for the analytical model. The 16 mm voxel model produced unacceptably large discrepancies for all dose components. The effects from different kerma data sets and tissue compositions were evaluated. Updating the kerma data from ICRU 46 to ICRU 63 data produced less than 2% difference in kerma rate profiles. The depth-dose profile data, Monte Carlo code input, kerma factors, and model construction files are available electronically to aid in verifying new and existing NCT treatment planning codes.
Collapse
|
|
23 |
97 |
3
|
Coderre JA, Turcotte JC, Riley KJ, Binns PJ, Harling OK, Kiger WS. Boron neutron capture therapy: cellular targeting of high linear energy transfer radiation. Technol Cancer Res Treat 2004; 2:355-75. [PMID: 14529302 DOI: 10.1177/153303460300200502] [Citation(s) in RCA: 82] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Boron neutron capture therapy (BNCT) is based on the preferential targeting of tumor cells with (10)B and subsequent activation with thermal neutrons to produce a highly localized radiation. In theory, it is possible to selectively irradiate a tumor and the associated infiltrating tumor cells with large single doses of high-LET radiation while sparing the adjacent normal tissues. The mixture of high- and low-LET dose components created in tissue during neutron irradiation complicates the radiobiology of BNCT. Much of the complexity has been unravelled through a combination of preclinical experimentation and clinical dose escalation experience. Over 350 patients have been treated in a number of different facilities worldwide. The accumulated clinical experience has demonstrated that BNCT can be delivered safely but is still defining the limits of normal brain tolerance. Several independent BNCT clinical protocols have demonstrated that BNCT can produce median survivals in patients with glioblastoma that appear to be equivalent to conventional photon therapy. This review describes the individual components and methodologies required for effect BNCT: the boron delivery agents; the analytical techniques; the neutron beams; the dosimetry and radiation biology measurements; and how these components have been integrated into a series of clinical studies. The single greatest weakness of BNCT at the present time is non-uniform delivery of boron into all tumor cells. Future improvements in BNCT effectiveness will come from improved boron delivery agents, improved boron administration protocols, or through combination of BNCT with other modalities.
Collapse
|
Review |
21 |
82 |
4
|
Busse PM, Harling OK, Palmer MR, Kiger WS, Kaplan J, Kaplan I, Chuang CF, Goorley JT, Riley KJ, Newton TH, Santa Cruz GA, Lu XQ, Zamenhof RG. A critical examination of the results from the Harvard-MIT NCT program phase I clinical trial of neutron capture therapy for intracranial disease. J Neurooncol 2003; 62:111-21. [PMID: 12749707 DOI: 10.1007/bf02699938] [Citation(s) in RCA: 81] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A phase I trial was designed to evaluate normal tissue tolerance to neutron capture therapy (NCT); tumor response was also followed as a secondary endpoint. Between July 1996 and May 1999, 24 subjects were entered into a phase I trial evaluating cranial NCT in subjects with primary or metastatic brain tumors. Two subjects were excluded due to a decline in their performance status and 22 subjects were irradiated at the MIT Nuclear Reactor Laboratory. The median age was 56 years (range 24-78). All subjects had a pathologically confirmed diagnosis of either glioblastoma (20) or melanoma (2) and a Karnofsky of 70 or higher. Neutron irradiation was delivered with a 15 cm diameter epithermal beam. Treatment plans varied from 1 to 3 fields depending upon the size and location of the tumor. The 10B carrier, L-p-boronophenylalanine-fructose (BPA-f), was infused through a central venous catheter at doses of 250 mg kg(-1) over 1 h (10 subjects), 300 mg kg(-1) over 1.5 h (two subjects), or 350 mg kg(-1) over 1.5-2 h (10 subjects). The pharmacokinetic profile of 10B in blood was very reproducible and permitted a predictive model to be developed. Cranial NCT can be delivered at doses high enough to exhibit a clinical response with an acceptable level of toxicity. Acute toxicity was primarily associated with increased intracranial pressure; late pulmonary effects were seen in two subjects. Factors such as average brain dose, tumor volume, and skin, mucosa, and lung dose may have a greater impact on tolerance than peak dose alone. Two subjects exhibited a complete radiographic response and 13 of 17 evaluable subjects had a measurable reduction in enhanced tumor volume following NCT.
Collapse
|
Clinical Trial |
22 |
81 |
5
|
Kiger WS, Sakamoto S, Harling OK. Neutronic Design of a Fission Converter-Based Epithermal Neutron Beam for Neutron Capture Therapy. NUCL SCI ENG 2017. [DOI: 10.13182/nse99-a2015] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
|
8 |
66 |
6
|
Kiger WS, Palmer MR, Riley KJ, Zamenhof RG, Busse PM. A pharmacokinetic model for the concentration of 10B in blood after boronophenylalanine-fructose administration in humans. Radiat Res 2001; 155:611-8. [PMID: 11260663 DOI: 10.1667/0033-7587(2001)155[0611:apmftc]2.0.co;2] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
An open two-compartment model has been developed for predicting (10)B concentrations in blood after intravenous infusion of the l-p-boronophenylalanine-fructose complex (BPA-F) in humans and derived from studies of pharmacokinetics in 24 patients in the Harvard-MIT Phase I clinical trials of BNCT. The (10)B concentration profile in blood exhibits a characteristic rise during the infusion to a peak of approximately 32 microg/g (for infusion of 350 mg/kg over 90 min) followed by a biphasic exponential clearance profile with half-lives of 0.34 +/- 0.12 and 9.0 +/- 2.7 h, due to redistribution and primarily renal elimination, respectively. The model rate constants k(1), k(2) and k(3) are 0.0227 +/- 0.0064, 0.0099 +/- 0.0027 and 0.0052 +/- 0.0016 min(-1), respectively, and the central compartment volume of distribution, V(1), is 0.235 +/- 0.042 kg/kg. The validity of this model was demonstrated by successfully predicting the average pharmacokinetic response for a cohort of patients who were administered BPA-F using an infusion schedule different from those used to derive the parameters of the model. Furthermore, the mean parameters of the model do not differ for cohorts of patients infused using different schedules.
Collapse
|
Clinical Trial |
24 |
52 |
7
|
Palmer MR, Goorley JT, Kiger WS, Busse PM, Riley KJ, Harling OK, Zamenhof RG. Treatment planning and dosimetry for the Harvard-MIT Phase I clinical trial of cranial neutron capture therapy. Int J Radiat Oncol Biol Phys 2002; 53:1361-79. [PMID: 12128139 DOI: 10.1016/s0360-3016(02)02862-6] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE A Phase I trial of cranial neutron capture therapy (NCT) was conducted at Harvard-MIT. The trial was designed to determine maximum tolerated NCT radiation dose to normal brain. METHODS AND MATERIALS Twenty-two patients with brain tumors were treated by infusion of boronophenylalanine-fructose (BPA-f) followed by exposure to epithermal neutrons. The study began with a prescribed biologically weighted dose of 8.8 RBE (relative biologic effectiveness) Gy, escalated in compounding 10% increments, and ended at 14.2 RBE Gy. BPA-f was infused at a dose 250-350 mg/kg body weight. Treatments were planned using MacNCTPlan and MCNP 4B. Irradiations were delivered as one, two, or three fields in one or two fractions. RESULTS Peak biologically weighted normal tissue dose ranged from 8.7 to 16.4 RBE Gy. The average dose to brain ranged from 2.7 to 7.4 RBE Gy. Average tumor dose was estimated to range from 14.5 to 43.9 RBE Gy, with a mean of 25.7 RBE Gy. CONCLUSIONS We have demonstrated that BPA-f-mediated NCT can be precisely planned and delivered in a carefully controlled manner. Subsequent clinical trials of boron neutron capture therapy at Harvard and MIT will be initiated with a new high-intensity, high-quality epithermal neutron beam.
Collapse
|
Clinical Trial |
23 |
46 |
8
|
Harling OK, Riley KJ, Newton TH, Wilson BA, Bernard JA, Hu LW, Fonteneau EJ, Menadier PT, Ali SJ, Sutharshan B, Kohse GE, Ostrovsky Y, Stahle PW, Binns PJ, Kiger WS, Busse PM. The Fission Converter-Based Epithermal Neutron Irradiation Facility at the Massachusetts Institute of Technology Reactor. NUCL SCI ENG 2017. [DOI: 10.13182/nse02-a2258] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
|
8 |
46 |
9
|
Sakamoto S, Kiger WS, Harling OK. Sensitivity studies of beam directionality, beam size, and neutron spectrum for a fission converter-based epithermal neutron beam for boron neutron capture therapy. Med Phys 1999; 26:1979-88. [PMID: 10505888 DOI: 10.1118/1.598784] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Sensitivity studies of epithermal neutron beam performance in boron neutron capture therapy are presented for realistic neutron beams with varying filter/moderator and collimator/delimiter designs to examine the relative importance of neutron beam spectrum, directionality, and size. Figures of merit for in-air and in-phantom beam performance are calculated via the Monte Carlo technique for different well-optimized designs of a fission converter-based epithermal neutron beam with head phantoms as the irradiation target. It is shown that increasing J/phi, a measure of beam directionality, does not always lead to corresponding monotonic improvements in beam performance. Due to the relatively low significance, for most configurations, of its effect on in-phantom performance and the large intensity losses required to produce beams with very high J/phi, beam directionality should not be considered an important figure of merit in epithermal neutron beam design except in terms of its consequences on patient positioning and collateral dose. Hardening the epithermal beam spectrum, while maintaining the specific fast neutron dose well below the inherent hydrogen capture dose, improves beam penetration and advantage depth and, as a desirable by-product, significantly increases beam intensity. Beam figures of merit are shown to be strongly dependent on beam size relative to target size. Beam designs with J/phi approximately 0.65-0.7, specific fast neutron doses of 2-2.6x10(-13) Gy cm2/n and beam sizes equal to or larger than the size of the head target produced the deepest useful penetration, highest therapeutic ratios, and highest intensities.
Collapse
|
|
26 |
30 |
10
|
Kiger WS, Lu XQ, Harling OK, Riley KJ, Binns PJ, Kaplan J, Patel H, Zamenhof RG, Shibata Y, Kaplan ID, Busse PM, Palmer MR. Preliminary treatment planning and dosimetry for a clinical trial of neutron capture therapy using a fission converter epithermal neutron beam. Appl Radiat Isot 2005; 61:1075-81. [PMID: 15308195 DOI: 10.1016/j.apradiso.2004.05.008] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A Phase I/II clinical trial of neutron capture therapy (NCT) was conducted at Harvard-MIT using a fission converter epithermal neutron beam. This epithermal neutron beam has nearly ideal performance characteristics (high intensity and purity) and is well-suited for clinical use. Six glioblastoma multiforme (GBM) patients were treated with NCT by infusion of the tumor-selective amino acid boronophenylalanine-fructose (BPA-F) at a dose of 14.0 g/m(2) body surface area over 90 min followed by irradiation with epithermal neutrons. Treatments were planned using NCTPlan and an accelerated version of the Monte Carlo radiation transport code MCNP 4B. Treatments were delivered in two fractions with two or three fields. Field order was reversed between fractions to equalize the average blood boron concentration between fields. The initial dose in the dose escalation study was 7.0 RBEGy, prescribed as the mean dose to the whole brain volume. This prescription dose was increased by 10% to 7.7 RBEGy in the second cohort of patients. A pharmacokinetic model was used to predict the blood boron concentration for determination of the required beam monitor units with good accuracy; differences between prescribed and delivered doses were 1.5% or less. Estimates of average tumor doses ranged from 33.7 to 83.4 RBEGy (median 57.8 RBEGy), a substantial improvement over our previous trial where the median value of the average tumor dose was 25.8 RBEGy.
Collapse
|
Research Support, U.S. Gov't, P.H.S. |
20 |
26 |
11
|
Kiger JL, Kiger WS, Riley KJ, Binns PJ, Patel H, Hopewell JW, Harling OK, Busse PM, Coderre JA. Functional and Histological Changes in Rat Lung after Boron Neutron Capture Therapy. Radiat Res 2008; 170:60-9. [DOI: 10.1667/rr1266.1] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2007] [Accepted: 02/29/2008] [Indexed: 11/03/2022]
|
|
17 |
25 |
12
|
Binns PJ, Riley KJ, Harling OK, Kiger WS, Munck af Rosenschöld PM, Giusti V, Capala J, Sköld K, Auterinen I, Serén T, Kotiluoto P, Uusi-Simola J, Marek M, Viererbl L, Spurny F. An international dosimetry exchange for boron neutron capture therapy. Part I: Absorbed dose measurements. Med Phys 2006; 32:3729-36. [PMID: 16475772 DOI: 10.1118/1.2132572] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
An international collaboration was organized to undertake a dosimetry exchange to enable the future combination of clinical data from different centers conducting neutron capture therapy trials. As a first step (Part I) the dosimetry group from the Americas, represented by MIT, visited the clinical centers at Studsvik (Sweden), VTT Espoo (Finland), and the Nuclear Research Institute (NRI) at Rez (Czech Republic). A combined VTT/NRI group reciprocated with a visit to MIT. Each participant performed a series of dosimetry measurements under equivalent irradiation conditions using methods appropriate to their clinical protocols. This entailed in-air measurements and dose versus depth measurements in a large water phantom. Thermal neutron flux as well as fast neutron and photon absorbed dose rates were measured. Satisfactory agreement in determining absorbed dose within the experimental uncertainties was obtained between the different groups although the measurement uncertainties are large, ranging between 3% and 30% depending upon the dose component and the depth of measurement. To improve the precision in the specification of absorbed dose amongst the participants, the individually measured dose components were normalized to the results from a single method. Assuming a boron concentration of 15 microg g(-1) that is typical of concentrations realized clinically with the boron delivery compound boronophenylalanine-fructose, systematic discrepancies in the specification of the total biologically weighted dose of up to 10% were apparent between the different groups. The results from these measurements will be used in future to normalize treatment plan calculations between the different clinical dosimetry protocols as Part II of this study.
Collapse
|
Research Support, U.S. Gov't, Non-P.H.S. |
19 |
23 |
13
|
Coderre JA, Hopewell JW, Turcotte JC, Riley KJ, Binns PJ, Kiger WS, Harling OK. Tolerance of normal human brain to boron neutron capture therapy. Appl Radiat Isot 2004; 61:1083-7. [PMID: 15308196 DOI: 10.1016/j.apradiso.2004.05.009] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Data from the Harvard-MIT and the BNL Phase I and Phase I/II clinical trials, conducted between 1994 and 1999, have been analyzed and combined, providing the most complete data set yet available on the tolerance of the normal human brain to BPA-mediated boron neutron capture therapy. Both peak (1cm(3)) dose and average whole-brain dose show a steep dose-response relationship using somnolence syndrome as the clinical endpoint. Probit analysis indicates that the doses associated with a 50% incidence for somnolence (ED(50)+/-SE) were 6.2+/-1.0 Gy(w) for average whole-brain dose and 14.1+/-1.8 Gy(w) for peak brain dose.
Collapse
|
|
21 |
23 |
14
|
Kiger WS, Palmer MR, Riley KJ, Zamenhof RG, Busse PM. Pharamacokinetic modeling for boronophenylalanine-fructose mediated neutron capture therapy: 10B concentration predictions and dosimetric consequences. J Neurooncol 2003; 62:171-86. [PMID: 12749712 DOI: 10.1007/bf02699943] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
A two-compartment open model has been developed for predicting 10B concentrations in blood following intravenous infusion of the L-p-boronophenylalanine-fructose complex in humans and derived from pharmacokinetic studies of 24 patients in Phase I clinical trials of boron neutron capture therapy. The 10B concentration profile in blood exhibits a characteristic rise during the infusion to a peak of approximately 32 microg/g (for infusion of 350 mg/kg over 90 min) followed by a biexponential disposition profile with harmonic mean half-lives of 0.32 +/- 0.08 and 8.2 +/- 2.7 h, most likely due to redistribution and primarily renal elimination, respectively. The mean model rate constants k12, k21, and k10 are (mean +/- SD) 0.0227 +/- 0.0064 min(-1), 0.0099 +/- 0.0027 min(-1), 0.0052 +/- 0.0016 min(-1), respectively, and the central compartment volume of distribution V1 is 0.235 +/- 0.042 L/kg. In anticipation of the initiation of clinical trials using an intense neutron beam with concomitantly short irradiations, the ability of this model to predict, in advance, the average blood 10B concentration during brief irradiations was simulated in a retrospective analysis of the pharmacokinetic data from these patients. The prediction error for blood boron concentration and its effect on simulated dose delivered for each irradiation field are reported for three different prediction strategies. In this simulation, error in delivered dose (or, equivalently, neutron fluence) for a given single irradiation field resulting from error in predicted blood 10B concentration was limited to less than 10%. In practice, lower dose errors can be achieved by delivering each field in two fractions (on two separate days) and by adjusting the second fraction's dose to offset error in the first.
Collapse
|
Clinical Trial |
22 |
22 |
15
|
Kiger JL, Kiger WS, Patel H, Binns PJ, Riley KJ, Hopewell JW, Harling OK, Coderre JA. Effects of boron neutron capture irradiation on the normal lung of rats. Appl Radiat Isot 2004; 61:969-73. [PMID: 15308177 DOI: 10.1016/j.apradiso.2004.05.021] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The whole lung of rats was irradiated with X-rays, thermal neutrons, or thermal neutrons in the presence of p-boronophenylalanine (BPA). A >/= 20% increase in breathing rate, in the period 40-80 days after irradiation, was indicative of radiation-induced pneumonitis. The ED(50) (+/-SE) for a >/= 20% increase in breathing rate, relative to age-matched controls, was 11.6 +/- 0.13 Gy for X-rays and 9.6 +/- 0.08 Gy for neutrons only. This indicated a thermal neutron beam RBE of 1.2 and an RBE of 2.2 for the high-LET components of the dose, assuming a dose reduction factor of 1.0 for gamma rays. Preliminary data indicate the compound biological effectiveness factor for BPA in the lung is approximately 1.5.
Collapse
|
|
21 |
14 |
16
|
Kiger WS, Micca PL, Morris GM, Coderre JA. Boron microquantification in oral muscosa and skin following administration of a neutron capture therapy agent. RADIATION PROTECTION DOSIMETRY 2002; 99:409-412. [PMID: 12194342 DOI: 10.1093/oxfordjournals.rpd.a006820] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Clinical trials of boron neutron capture therapy (BNCT) for intracranial tumours using boronophenylalanine-fructose undertaken at Harvard-MIT and Brookhaven National Laboratory have observed acute normal tissue reactions in the skin and oral mucosa. Because the range of the 10B(n, alpha)7Li reaction products is very short, 10-14 microns combined, knowledge of the 10B microdistribution in tissue is critical for understanding the microdosimetry and radiobiology of BNCT. This paper reports measurements of the microdistribution of 10B in an animal model, rat skin and tongue, using high resolution quantitative autoradiography (HRQAR), a neutron-induced etched track autoradiographic technique. The steep spatial gradient and high absolute value relative to blood of the 10B concentration observed in some strata of the rat tongue epithelium and skin are important for properly evaluating the radiobiology and the biological effectiveness factors for normal tissue reactions such as oral mucositis, which are generally assessed using the blood boron concentration rather than the tissue boron concentration.
Collapse
|
|
23 |
12 |
17
|
Riley KJ, Binns PJ, Harling OK, Albritton JR, Kiger WS, Rezaei A, Sköld K, Seppälä T, Savolainen S, Auterinen I, Marek M, Viererbl L, Nievaart VA, Moss RL. An international dosimetry exchange for BNCT part II: computational dosimetry normalizations. Med Phys 2009; 35:5419-25. [PMID: 19175101 DOI: 10.1118/1.3005480] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The meaningful sharing and combining of clinical results from different centers in the world performing boron neutron capture therapy (BNCT) requires improved precision in dose specification between programs. To this end absorbed dose normalizations were performed for the European clinical centers at the Joint Research Centre of the European Commission, Petten (The Netherlands), Nuclear Research Institute, Rez (Czech Republic), VTT, Espoo (Finland), and Studsvik, Nyköping (Sweden). Each European group prepared a treatment plan calculation that was bench-marked against Massachusetts Institute of Technology (MIT) dosimetry performed in a large, water-filled phantom to uniformly evaluate dose specifications with an estimated precision of +/-2%-3%. These normalizations were compared with those derived from an earlier exchange between Brookhaven National Laboratory (BNL) and MIT in the USA. Neglecting the uncertainties related to biological weighting factors, large variations between calculated and measured dose are apparent that depend upon the 10B uptake in tissue. Assuming a boron concentration of 15 microg g(-1) in normal tissue, differences in the evaluated maximum dose to brain for the same nominal specification of 10 Gy(w) at the different facilities range between 7.6 and 13.2 Gy(w) in the trials using boronophenylalanine (BPA) as the boron delivery compound and between 8.9 and 11.1 Gy(w) in the two boron sulfhydryl (BSH) studies. Most notably, the value for the same specified dose of 10 Gy(w) determined at the different participating centers using BPA is significantly higher than at BNL by 32% (MIT), 43% (VTT), 49% (JRC), and 74% (Studsvik). Conversion of dose specification is now possible between all active participants and should be incorporated into future multi-center patient analyses.
Collapse
|
Research Support, U.S. Gov't, Non-P.H.S. |
16 |
11 |
18
|
Petit JH, Gluck C, Kiger WS, Henry DL, Karasiewicz C, Talcott J, Berg S, Holupka E, Kaplan I. Bicalutamide alone prior to brachytherapy achieves cytoreduction that is similar to luteinizing hormone-releasing hormone analogues with less patient-reported morbidity. Urol Oncol 2008; 26:372-7. [PMID: 18367113 DOI: 10.1016/j.urolonc.2007.05.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2007] [Revised: 04/28/2007] [Accepted: 05/08/2007] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To compare the impact of bicalutamide (B) vs. luteinizing hormone-releasing hormone analogues (LHRHa) on prostate volume, patient-reported side effects, and postimplant urinary toxicity in the setting of interstitial brachytherapy for early-stage prostate cancer. METHODS Between May 1998 and January 2004, 81 patients received androgen-deprivation therapy (ADT) for cytoreduction prior to interstitial brachytherapy alone. Fifty-six patients received LHRHa and 25 patients received B. Prostate volumes were measured prospectively prior to initiating therapy, and then intraoperatively at the time of implant by a single, blinded ultrasonographer. Patient-reported quality of life data were obtained prospectively, and postimplant urinary toxicity (catheter dependency and need for surgical intervention) was recorded during follow-up. Median follow-up was 53 (range 23-78) months. RESULTS The median percentage prostate volume reductions of 26% for B and 32% for LHRHa were not statistically different (P = 0.61). Decrements in libido (92% vs. 44%, P < 0.001) and erectile function (79% vs. 20%) were reported in more respondents treated with LHRHa than B. The incidence of recatheterization (28% vs. 24%, P = 0.34), and the need for subsequent surgical intervention (11% vs. 4%, P = 0.16) were similar for patients treated with LHRHa and B. CONCLUSIONS The degree of prostate downsizing with B is similar to that achieved with LHRHa. B was associated with fewer patient-reported sexual side effects and similar urinary morbidity. A randomized trial is needed to establish whether LHRHa or B should be the standard of care for prostate downsizing before interstitial brachytherapy.
Collapse
|
Journal Article |
17 |
10 |
19
|
Lu XQ, Kiger WS. Application of a Novel Microdosimetry Analysis and its Radiobiological Implication for High-LET Radiation. Radiat Res 2009; 171:646-56. [DOI: 10.1667/rr1612.1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
|
16 |
9 |
20
|
Binns PJ, Riley KJ, Harling OK, Auterinen I, Marek M, Kiger WS. Progress with the NCT international dosimetry exchange. Appl Radiat Isot 2005; 61:865-8. [PMID: 15308159 DOI: 10.1016/j.apradiso.2004.05.044] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The international collaboration that was organized to undertake a dosimetry exchange for purposes of combining clinical data from different facilities conducting neutron capture therapy has continued since its founding at the 9th ISNCT symposium in October 2000. The thrust towards accumulating physical dosimetry data for comparison between different participants has broadened to include facilities in Japan and the determination of spectral descriptions of different beams. Retrospective analysis of patient data from the Brookhaven Medical Research Reactor is also being considered for incorporation into this study to increase the pool of available data. Meanwhile the next essential phase of comparing measurements of visiting dosimetry groups with treatment plan calculations from the host institutes has commenced. Host centers from Petten, Finland and the Czech Republic in Europe and MIT in the USA have applied the regular calculations and clinical calibrations from their current clinical studies, to generate treatment plans in the large standard phantom used for measurements by visiting participants. These data have been exchanged between the participants and scaling factors to relate the separate dose components between the different institutes are being determined. Preliminary normalization of measured and calculated dosimetry for patients is nearing completion to enable the physical radiation doses that comprise a treatment prescription at a host institute to be directly related to the corresponding measured doses of a visiting group. This should serve as an impetus for the direct comparison of patient data although the clinical requirements for achieving this need to be clearly defined. This may necessitate more extensive comparisons of treatment planning calculations through the solution of test problems and clarification regarding the question of dose specification from treatment calculations in general.
Collapse
|
Research Support, U.S. Gov't, Non-P.H.S. |
20 |
9 |
21
|
Binns PJ, Riley KJ, Ostrovsky Y, Gao W, Albritton JR, Kiger WS, Harling OK. Improved Dose Targeting for a Clinical Epithermal Neutron Capture Beam Using Optional 6Li Filtration. Int J Radiat Oncol Biol Phys 2007; 67:1484-91. [PMID: 17394946 DOI: 10.1016/j.ijrobp.2006.11.022] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2006] [Revised: 11/07/2006] [Accepted: 11/09/2006] [Indexed: 10/23/2022]
Abstract
PURPOSE The aim of this study was to construct a (6)Li filter and to improve penetration of thermal neutrons produced by the fission converter-based epithermal neutron beam (FCB) for brain irradiation during boron neutron capture therapy (BNCT). METHODS AND MATERIALS Design of the (6)Li filter was evaluated using Monte Carlo simulations of the existing beam line and radiation transport through an ellipsoidal water phantom. Changes in beam performance were determined using three figures of merit: (1) advantage depth (AD), the depth at which the total biologically weighted dose to tumor equals the maximum weighted dose to normal tissue; (2) advantage ratio (AR), the ratio of the integral tumor dose to that of normal tissue averaged from the surface to the AD; and (3) advantage depth dose rate (ADDR), the therapeutic dose rate at the AD. Dosimetry performed with the new filter installed provided calibration data for treatment planning. Past treatment plans were recalculated to illustrate the clinical potential of the filter. RESULTS The 8-mm-thick Li filter is more effective for smaller field sizes, increasing the AD from 9.3 to 9.9 cm, leaving the AR unchanged at 5.7 but decreasing the ADDR from 114 to 55 cGy min(-1) for the 12 cm diameter aperture. Using the filter increases the minimum deliverable dose to deep seated tumors by up to 9% for the same maximum dose to normal tissue. CONCLUSIONS Optional (6)Li filtration provides an incremental improvement in clinical beam performance of the FCB that could help to establish a therapeutic window in the future treatment of deep-seated tumors.
Collapse
|
|
18 |
8 |
22
|
Riley KJ, Binns PJ, Harling OK, Kiger WS, González SJ, Casal MR, Longhino J, Larrieu OAC, Blaumann HR. Unifying dose specification between clinical BNCT centers in the Americas. Med Phys 2008; 35:1295-8. [PMID: 18491523 DOI: 10.1118/1.2884856] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
A dosimetry intercomparison between the boron neutron capture therapy groups of the Massachusetts Institute of Technology (MIT) and the Comisión Nacional de Energía Atómica (CNEA), Argentina was performed to enable combined analyses of NCT patient data between the different centers. In-air and dose versus depth measurements in a rectangular water phantom were performed at the hyperthermal neutron beam facility of the RA-6 reactor, Bariloche. Calculated dose profiles from the CNEA treatment planning system NCTPlan that were calibrated against in-house measurements required normalizations of 1.0 (thermal neutrons), 1.13 (photons), and 0.74 (fast neutrons) to match the dosimetry of MIT.
Collapse
|
Research Support, U.S. Gov't, Non-P.H.S. |
17 |
6 |
23
|
Elyutina AS, Kiger WS, Portnov AA. NCTPlan application for neutron capture therapy dosimetric planning at MEPhI nuclear research reactor. Appl Radiat Isot 2011; 69:1888-91. [PMID: 21767957 DOI: 10.1016/j.apradiso.2011.04.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2011] [Revised: 04/18/2011] [Accepted: 04/18/2011] [Indexed: 10/18/2022]
Abstract
The results of modeling of two therapeutic beams HEC-1 and HEC-4 at the NRNU "MEPhI" research nuclear reactor exploitable for preclinical treatments are reported. The exact models of the beams are constructed as an input to the NCTPlan code used for planning Neutron Capture Therapy (NCT) procedure. The computations are purposed to improve the accuracy of prediction of a dose absorbed in tissue with the account of all components of radiation.
Collapse
|
|
14 |
3 |
24
|
Kiger WS, Albritton JR, Lu XQ, Palmer MR. Development and application of an unconstrained technique for patient positioning in fixed radiation beams. Appl Radiat Isot 2004; 61:765-9. [PMID: 15308141 DOI: 10.1016/j.apradiso.2004.05.050] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
A flexible technique for positioning patients in fixed orientation radiation fields such as those used in neutron capture therapy (NCT) has been developed. The positioning technique employs reference points marked on the patient in combination with a 3D digitizer to determine the beam entry point and a template fitted to the patient's head is used to determine the proper beam orientation. A coordinate transformation between the CT image data and reference points on the patient determined by a least squares algorithm based on singular value decomposition is used to map the beam entry point from the planning system onto the patient. The technique was validated in a phantom study where the mean error in entry point placement was 1.3 mm. Five glioblastoma multiforme patients have been treated with NCT using this positioning technique.
Collapse
|
|
21 |
3 |
25
|
Schmidt DR, Gramatikov IMT, Sheen A, Williams CL, Hurwitz M, Dodge LE, Holupka E, Kiger WS, Cornwall-Brady MR, Huang W, Mak HH, Cormier KS, Condon C, Dane Wittrup K, Yilmaz ÖH, Stevenson MA, Down JD, Floyd SR, Roper J, Vander Heiden MG. Ablative radiotherapy improves survival but does not cure autochthonous mouse models of prostate and colorectal cancer. COMMUNICATIONS MEDICINE 2023; 3:108. [PMID: 37558833 PMCID: PMC10412558 DOI: 10.1038/s43856-023-00336-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Accepted: 07/24/2023] [Indexed: 08/11/2023] Open
Abstract
BACKGROUND Genetically engineered mouse models (GEMMs) of cancer are powerful tools to study mechanisms of disease progression and therapy response, yet little is known about how these models respond to multimodality therapy used in patients. Radiation therapy (RT) is frequently used to treat localized cancers with curative intent, delay progression of oligometastases, and palliate symptoms of metastatic disease. METHODS Here we report the development, testing, and validation of a platform to immobilize and target tumors in mice with stereotactic ablative RT (SART). Xenograft and autochthonous tumor models were treated with hypofractionated ablative doses of radiotherapy. RESULTS We demonstrate that hypofractionated regimens used in clinical practice can be effectively delivered in mouse models. SART alters tumor stroma and the immune environment, improves survival in GEMMs of primary prostate and colorectal cancer, and synergizes with androgen deprivation in prostate cancer. Complete pathologic responses were achieved in xenograft models, but not in GEMMs. CONCLUSIONS While SART is capable of fully ablating xenografts, it is unable to completely eradicate disease in GEMMs, arguing that resistance to potentially curative therapy can be modeled in GEMMs.
Collapse
|
research-article |
2 |
1 |