1
|
Preliminary Experimental Study about the Feasibility of Combining Pulsatile Cardiopulmonary Support System and a Membrane Oxygenator. Int J Artif Organs 2018. [DOI: 10.1177/039139889601901007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A cardiopulmonary support (CPS) device that incorporated a pneumatic ventricular assist device (VAD) and a membrane oxygenator was developed for the support of patients with profound heart and/or respiratory failure. This device has an advantage of being both a pulsatile assist device and membrane oxygenator. A “triple flow” regulator was included in this system to control the blood flow through the oxygenator. The purpose of this study was to clarify the efficacy of this system in supporting an animal model with combined cardiac and respiratory failure. In vitro tests showed 3.7 L/min of pump flow under 1.6 L/min of oxygen supply to the oxygenator even though there was a 50% clamp of a “triple flow” regulator with sufficient pulsatility. In 14 acute canine experiments, cardiogenic shock and acute respiratory failure were introduced by coronary ligation and mechanical hypoventilation simultaneously. The pump flow was maintaned at 1.95 - 0.6 L/min (average 1.2 L/min) and the driving pressure of the pump was controlled between 200 and 300 mmHg positive pressure and -20 to -50 mmHg negative pressure. The driving rate was fixed at 100 bpm and systolic/diastolic ratio was controlled between 35-50%. The canines were divided into control group (n=4) and pumped group (drained from the right atrium n=7, drained from the left atrium n=3). By using CPS system, flow and aortic pressure recovered to the initial baseline level. Without this support, the canine model could not maintain systemic circulation. In the group drained from right atrium, central venous pressure decreased with the device from 13.9 ± 2.4 to 5.6 ± 1.4 cm H2O (p<0.01), returned to the initial level without this device (p<0.01). In the group drained from left atrium, pulmonary capillary wedge pressure decreased from 37.9 ± 4.6 to 20.8 ± 5.7 mmHg (p<0.01), and returned to the initial level without the device, arterial oxygen tension levels increased (p<0.01), and also arterial oxygen saturation levels recovered (p<0.01). The results suggest that the current model of the pulsatile CPS has a potential to support the animal model with combined cardiac and respiratory failure.
Collapse
|
2
|
|
3
|
[Reoperation for a Starr-Edwards ball valve prosthesis implanted in mitral position 31 years ago]. KYOBU GEKA. THE JAPANESE JOURNAL OF THORACIC SURGERY 2003; 56:535-40. [PMID: 12854458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/03/2023]
Abstract
The patient is a 61-year-old woman who had undergone mitral valve replacement with the Starr-Edwards cloth-covered ball valve 31 years ago. She had dyspnea on effort 1 month before admission. The echocardiography revealed mitral and tricuspid regurgitation. Re-replacement of the mitral prosthetic valve with an ATS valve and tricuspid annuloplasty were successfully performed without any complication. The cloth wear of the Starr-Edwards ball valve cage was recognized and no thrombus was found at operation. To our knowledge, there has been no such a reoperative case who underwent so long postoperative period after initial implantation of the Starr-Edwards ball valve in Japan. This experience made us realize again the importance of attention to the complications related to a prosthetic valve like a cloth wear during long-term follow-up for the Starr-Edwards ball valve.
Collapse
|
4
|
Abstract
The rotary blood pump is implanted as a bridge to cardiac transplantation. Mechanical, histological, and biochemical improvements have been described in patients after implantation of left ventricular assist devices (LVADs). Thus, the rotary blood pump might be used as a bridge to recovery of myocardial function. However, unlike a pulsatile pump, the rotary blood pump cannot be stopped to estimate cardiac function: if the rotary blood pump stops, backflow will occur. In this study, a new method that can estimate cardiac function without pump stop was examined. Six pigs were the subjects of this acute study. The pump was implanted as an LVAD: the inlet cannula was inserted into the left ventricle, and the outlet cannula was inserted into the ascending aorta. The motor speed was regulated at a pump flow rate of 0 L/min at diastolic phase. Then, the relationship between the dp/dt of left ventricular pressure and external stroke work of actuator was examined. This method was studied at normal, hyperdynamic, and heart-failure conditions. There was a high positive correlation between the dp/dt of left ventricular pressure and external stroke work of actuator. This method is useful and simple to estimate cardiac function without pump stop.
Collapse
|
5
|
Effects of left ventricular assist device on cardiac function: experimental study of relationship between pump flow and left ventricular diastolic function. Artif Organs 2001; 25:728-32. [PMID: 11722351 DOI: 10.1046/j.1525-1594.2001.06865.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The left ventricular assist device (LVAD) with centrifugal pump has two characteristics. One is a pump flow wave of the centrifugal pump, consisting of the pulsatile flow of the native heart and the nonpulsatile flow of the centrifugal pump. The other is that the centrifugal pump fills from the native heart not only in the systolic phase, but also in the diastolic phase. In the case of the apex outlet LVAD with centrifugal pump, blood flows from the left atrium through the left ventricle to the pump. Pump flow is regulated by preload, and preload is regulated by diastolic hemodynamics. The aim of this study is to analyze the relationship between pump flow and the diastolic hemodynamics of the native heart. Ten anesthetized intact pigs were studied after placement of an LVAD. Data were recorded with the LVAD off (control) and the LVAD on. The assist rate was changed to 25%, 50%, and 75%. The indexes of left ventricular (LV) diastolic function included LV myocardial relaxation (time constant of isovolumic pressure decay [Tau] and maximum negative dP/dt [LV dP/dt min]) and LV filling (peak filling rate [PFR], time to peak filling rate [tPFR], and diastolic filling time [DFT]). Stroke volume decreased significantly in 75% assist. LV end-systolic pressure decreased significantly in 50% and 75% assist. LV end-diastolic volume decreased as assist rate increased, but there were no significant changes. Stroke work decreased significantly in 50% and 75% assist. LV dP/dt min decreased significantly in 50% and 75% assist. Tau prolonged as assist rate increased, but there were no significant changes. DFT shortened significantly in 75% assist. PFR increased significantly in 75% assist. tPFR shortened significantly in 50% and 75% assist. In this study, LV relaxation delayed as an increasing of pump assist rate, but it suggested a result of reduction of cardiac work. Also, it was suggested that LVAD increases the pressure difference between the left atrium and the left ventricle in the diastolic phase. This phenomenon is due to the filling of the left ventricle. In this study it was suggested that as pump assist rate increases, it is more effective to keep cardiac function in the diastolic phase.
Collapse
|
6
|
Evaluation of St. Jude Medical valve's long-term function by Doppler echocardiography. Ann Thorac Cardiovasc Surg 2001; 7:216-22. [PMID: 11578262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023] Open
Abstract
In this study, the long-term function of St. Jude Medical valve (SJM valve) is evaluated by Doppler echocardiography. The subjects were 191 patients who underwent mitral or aortic valve replacement using SJM valve in our institute since July 1978 and had no clinical problem showing more than 50% of left ventricular ejection fraction. The patients were classified into 3 groups according to measurement period (within 5 years, 10 years and 15 years and more), and further classified by size and their results were compared. In every group by size, there was no significant difference among groups by measurement period. In the mitral valve position, peak pressure gradient and pressure half-time were not significantly different among groups by size. On the other hand, in the aortic valve position, pressure gradient in 21-mm group was significantly high among 21-mm, 25-mm, and 27-mm groups, showing a negative correlation with size. As the result, it was suggested that SJM valve kept a good function more than 15 years after operation. From these results, it was considered that the patients with small annlus of the aortic valve needed annulus-enlarging procedure or use of Hemodynamic Plus series valves to keep the size of more than 23 mm.
Collapse
|
7
|
Doppler echocardiographic evaluation of St. Jude Medical valves in the tricuspid position: criteria for normal and abnormal valve function. THE JOURNAL OF CARDIOVASCULAR SURGERY 2001; 42:303-9. [PMID: 11398024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/20/2023]
Abstract
BACKGROUND Although this examination for mitral and aortic prosthetic valves has been frequently reported to be available for the early diagnosis of complications, there are few reports on examinations for tricuspid prosthetic valves, particularly the mechanical valve such as the St. Jude Medical (SJM) valve. Furthermore, the criteria for early diagnosis of complications are unknown. The purpose of this study is to evaluate the SJM valve in the tricuspid position by Doppler echocardiography and to analyze valve-related complications. METHODS Between September 1978 and March 1997, 46 patients underwent tricuspid valve replacements with SJM valves; these cases were evaluated by Doppler echocardiography. We divided the cases into Normal and Complication groups. RESULTS In the Normal group, peak pressure gradient was 4.2+/-1.5 mmHg and pressure half-time was 123.5+/-22.9 msec. In the Complication group, peak pressure gradient was 12.7+/-3.6 mmHg and pressure half-time was 271.8+/-76.4 msec. In the Complication group, the lowest peak pressure gradient case was 8.0 mmHg and the shortest pressure half-time was 160.0 msec. CONCLUSIONS We concluded that when the peak pressure gradient is more than 8 mmHg or the pressure half-time is more than 160 msec, there is a possibility of complications. Despite the problems, the absence of any structural change after more than ten years suggests that the SJM valve can be used in the tricuspid position with careful follow-up.
Collapse
|
8
|
Abstract
Progress in several types of artificial organs in the cardiovascular field has significantly contributed to advancements in cardiac surgery. Due to the progress of high technology in fields other than medicine, both cardiac surgery and artificial organs have shown rapid and remarkable advances. In recent years, several types of blood pumps have been developed that are widely used not only as the main pump of cardiopulmonary bypass but also for circulatory support of postcardiotomy cardiogenic shock. In this article, the progress and current status of percutaneous cardiopulmonary support systems and ventricular assist devices (VADs) are described. In addition, new centrifugal and axial pumps, which are compact and implantable clinical use devices, are introduced. I believe that by making developments toward the clinical application of artificial hearts or VADs, not only in Japan but also in cooperation with colleagues at various institutions throughout the world, we will be able to make some contributions to the progress in the field of cardiac surgery. In the 20th century, medical research showed remarkable advances, mainly in medical electronics and pathophysiology. However, in the next century, we have to focus on other research fields, namely artificial organs and gene technology.
Collapse
|
9
|
[A case report of treatment for tracheal fistula after radical esophagectomy]. KYOBU GEKA. THE JAPANESE JOURNAL OF THORACIC SURGERY 2000; 53:787-90. [PMID: 10935409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
We report our experience of the treatment of a 60-year-old man with upper tracheal fistula which developed on the 11th day after radical surgery for esophageal cancer. Primary treatment to close the fistula was unsuccessful, resulting in the involvement of empyema due to infection. Controlled ventilation with T-tube and drainage through a chest tube for 2 months lead to depuration of the thoracic cavity. As a strategy for secondary closure of the fistula, fenestration was performed on the 87th day postoperatively. The patient's overall condition improved thereafter and closure was being considered. However, the patient died on the 116th day postoperatively due to supervenient aspiration pneumonia. Thus, long-term controlled ventilation with a T-tube was beneficial for the treatment of central airway injury.
Collapse
|
10
|
Abstract
We evaluated the efficacy and problems of circulatory support with percutaneous cardiopulmonary support (PCPS) for severe cardiogenic shock and discussed our strategy of mechanical circulatory assist for severe cardiopulmonary failure. We also described the effects of an alternative way of PCPS as venoarterial (VA) bypass from the right atrium (RA) to the ascending aorta (Ao), which was used recently in 3 patients. Over the past 9 years, 30 patients (20 men and 10 women; mean age: 61 years) received perioperative PCPS at our institution. Indications of PCPS were cardiopulmonary bypass weaning in 13 patients, postoperative low output syndrome (LOS) in 14 patients, and preoperative cardiogenic shock in 3 patients. Approaches of the PCPS system were the femoral artery to the femoral vein (F-F) in 21 patients, the RA to the femoral artery (RA-FA) in 5 patients, the RA to the Ao (RA-Ao) in 3 patients, and the right and left atrium to the Ao in 1 patient. Seventeen (56.7%) patients were weaned from mechanical circulatory support (Group 1) and the remaining 13 patients were not (Group 2). In Group 1, PCPS running time was 33.1 +/- 13.6 h, which was significantly shorter than that of Group 2 (70.6 +/- 44.4 h). Left ventricular ejection fraction was improved from 34.8 +/- 12.0% at the pump to 42.5 +/- 4.6% after 24 h support in Group 1, which was significantly better than that of Group 2 (21.6 +/- 3.5%). In particular, it was 48.6 +/- 5.7% in the patients with RA-Ao, which was further improved. Two of 3 patients with RA-Ao were discharged. Thrombectomy was carried out for ischemic complication of the lower extremity in 5 patients with F-F and 1 patient with RA-FA. One patient with F-F needed amputation of the leg due to necrosis. Thirteen patients (43.3%) were discharged. Hospital mortality indicated 17 patients (56.7%). Fifteen patients died with multiple organ failure. In conclusion, our alternate strategy of assisted circulation for severe cardiac failure is as follows. In patients with postcardiotomy cardiogenic shock or LOS, PCPS should be applied first under intraaortic balloon pumping (IABP) assist for a maximum of 2 or 3 days. In older aged patients particularly, the RA-Ao approach of PCPS is superior to control flow rate easily, with less of the left ventricular afterload and ischemic complications of the lower extremity. If native cardiac function does not recover and longer support is necessary, several types of ventricular assist devices should be introduced, according to end-organ function and the expected support period.
Collapse
|
11
|
Two cases of quadricuspid aortic valve: preoperative diagnosis and surgical treatment. Ann Thorac Cardiovasc Surg 2000; 6:186-9. [PMID: 10899689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023] Open
Abstract
Two cases of severe aortic regurgitation were treated surgically. Both patients had a quadricuspid aortic valve, which was diagnosed preoperatively by aortography and/or transesophageal echocardiography (TEE). In the first patient, both aortic and mitral valve replacement were performed with an ATS prosthetic valve. In the second patient, only aortic valve replacement was performed. The postoperative course was uneventful in both cases. Quadricuspid aortic valve is relatively rare. We discuss the preoperative diagnosis of quadricuspid aortic valve, as well as reviewing the relevant literature.
Collapse
|
12
|
Removal of a chronically infected bipolar pacemaker electrode: a successful case report. JAPANESE CIRCULATION JOURNAL 2000; 64:452-4. [PMID: 10875736 DOI: 10.1253/jcj.64.452] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A chronic infected bipolar pacemaker electrode with a fin tip was successfully removed 7 years and 9 months after its original implantation from a 72-year-old Japanese man, using the Cook pacemaker lead extraction system. The locking stylet could not advance to the lead tip over the positive pole because of firm adhesions. Because the scar tissue between the positive pole and myocardium could not be freed by the inner sheath, it was disrupted by the slanted end of the outer sheath. The firmest adhesion was on the positive pole, not on the fin tip. The complete extraction success rate of bipolar tined or fin leads is worse than for other types of leads. When extracting a bipolar pacemaker lead, dissection of the positive pole from scar tissue should be taken into account in addition to the lead tip. Rotating the slanted end of the outer sheath is a useful technique when dissecting firm adhesions.
Collapse
|
13
|
Abstract
The Rota Flow pump is a fully integrated centrifugal pump system in the Jostra heart-lung machine HL-20 with features such as a less friction mono-pivot bearing system, sealless pump housing, and spiral housing. To evaluate its biocompatibility, antithrombogenesity, and hemolysis, we used it as a main pump of cardiopulmonary bypass (CPB) in coronary artery bypass grafting (CABG) cases and compared it with the BioMedicus pump. From February 1999 to May 1999, 30 consecutive patients underwent CABG under conventional CPB. Fifteen cases were supported by the Rota Flow RF-32 (Group R), and the remaining 15 were pumped by the BioMedicus BP-80 (Group B). In both groups, the flow rate was controlled in an equivalent value. Blood sampling was as follows: preoperative, 60 min after, postoperative Days (POD) 0, 1, and 2. We evaluated the plasma free hemoglobin (fHb) as the hemolysis parameter, beta-thromboglobulin (beta-TG) and platelet factor IV (PF-4) as the platelet deterioration index, C3, C4, and CH50 as complement activation, coagulation function, fibrinolytic factor and thrombomodulin, nitric oxide (NO), and endothelin as endothelial deterioration. This system was very easily and simply controlled and had excellent response. Perioperative laboratory data were not markedly changed in either group. The Rota Flow demonstrated equivalent value of biocompatibility and hemolysis as compared with the BioMedicus BP-80, which is a standard centrifugal pump. After pumping, no thrombus formation or pivot wear was observed inside the pump. This atraumatic, small centrifugal pump is suitable not only for CPB but also for long-term circulatory support.
Collapse
|
14
|
A case report of nonresective staple exclusion of abdominal aortic aneurysm associated with horseshoe kidney. Ann Thorac Cardiovasc Surg 2000; 6:199-202. [PMID: 10899693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023] Open
Abstract
A 55 year old male with a history of intermittent claudication presented with an abdominal mass, and was diagnosed by abdominal computed tomography (CT) with an abdominal aortic aneurysm accompanying horseshoe kidney. The horseshoe kidney configuration and governing vessels, urinary duct course, and right common iliac arterial stenosis were shown by methods such as angiogram, spiral CT, and intravenous pyelogram before operation. At the operation, the abdomen was opened by a median incision and, using a staple exclusion technique, the abnormal renal artery was reconstructed using 189 mm knitted Y shaped dacron graft replacement and the great saphenous vein. The isthmus was not resected. There were no post operative complications, nor was there any large decrease in renal function. Good results were obtained, and we herein report our results together with a discussion of the literature.
Collapse
|
15
|
Operative management of abdominal aortic aneurysm with left-sided inferior vena cava. THE JOURNAL OF CARDIOVASCULAR SURGERY 2000; 41:287-90. [PMID: 10901537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
Abdominal aortic aneurysm with left-sided inferior vena cava (IVC) is rare. In preoperative examination, it is important to conduct roentgenologic studies and determine any venous anomalies. Proximal anastomosis is technically difficult because the IVC crosses to the right on the aneurysmal neck. In this case of a 71-year-old Japanese man, proximal anastomosis was conducted safely under wide vena cava mobilization and contraction in the superior direction. In vein resection, vessels should be reconstructed because vein communication is not methodical.
Collapse
MESH Headings
- Aged
- Anastomosis, Surgical/methods
- Angiography, Digital Subtraction
- Aorta, Abdominal/diagnostic imaging
- Aorta, Abdominal/surgery
- Aortic Aneurysm, Abdominal/diagnostic imaging
- Aortic Aneurysm, Abdominal/surgery
- Blood Vessel Prosthesis Implantation
- Humans
- Iliac Artery/diagnostic imaging
- Iliac Artery/surgery
- Male
- Phlebography
- Tomography, X-Ray Computed
- Vena Cava, Inferior/abnormalities
- Vena Cava, Inferior/diagnostic imaging
- Vena Cava, Inferior/surgery
Collapse
|
16
|
Pathological findings of tissue reactivity of gelatin resorcin formalin glue: an autopsy case report of the repair of ventricular septal perforation. Ann Thorac Cardiovasc Surg 2000; 6:127-9. [PMID: 10870009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
Abstract
A seventy-three-year-old man was treated for ventricular septal perforation with Gelatin Resorcin Formalin (GRF) glue. The patient died of multiple organ failure 36 days after the surgery. In autopsy, macroscopically, the inferior wall was reconstructed successfully by the GRF glue. Furthermore, microscopic study revealed the excellent growth of collagen and elastic fiber where the GRF was glued. No infiltration of inflammatory cells was evident. There have been no reports that the safety and efficacy of GRF glue was pathologically proven in an autopsy case.
Collapse
|
17
|
Abstract
BACKGROUND We evaluated the effects of human atrial natriuretic peptide (hANP) during cardiopulmonary bypass (CPB). METHODS Forty patients undergoing coronary artery bypass grafting were investigated. A group of patients given hANP for 24 hours from the start of CPB (hANP group) was compared with a non-hANP group. Parameters examined were hemodynamics, urine volume, dosage of furosemide, respiratory index, pleural effusion, ANP, cyclic guanosine monophosphate, renin activity (renin), angiotensin-II, aldosterone, and glomerular filtration rate. RESULTS Central venous pressure, systemic vascular resistance index, and pulmonary vascular resistance index were significantly lower in the hANP group than in the non-hANP group. The hANP group showed significantly higher levels of ANP, cyclic guanosine monophosphate, glomerular filtration rate, and respiratory index, and significantly lower levels of renin, angiotensin-II, aldosterone, and pleural effusion, as compared with the non-hANP group. The dosage of furosemide was significantly lower and the urine volume was significantly larger in the hANP group. CONCLUSIONS hANP can satisfactorily compensate for the shortcomings of CPB by decreasing the peripheral vascular resistance, suppressing the renin-angiotensin-aldosterone system, and exerting a strong diuretic effect.
Collapse
|
18
|
Abstract
BACKGROUND We interviewed patients and carried out frequency analyses to compare the closing sounds of ATS and St. Jude Medical (SJM) prosthetic valves. METHODS Forty-five patients undergoing valve replacements using ATS valves were investigated. We interviewed patients at 1 month and 1 year after the operation, and carried out frequency analysis to investigate the prosthetic valve's closing sound. RESULTS According to the results of the interviews, 84.4% of patients with ATS valves were not aware of the valve sounds. ATS valves scored significantly lower than SJM valves on audibility of the valve sound, disturbance during daytime, sleep disturbance, request for replacement with a soundless prosthetic valve, audibility to others, and noise index. According to the frequency analysis on the prosthetic valve's closing sound, the sound peak of the ATS valves was around 1.2 kHz, and the sound pressure of the ATS valves was significantly lower than that of the SJM valves. CONCLUSIONS Though a further long-term observation on thromboembolism and hemolysis is needed for evaluation of prosthetic valves, the ATS valve is presently considered to impart a better quality of life.
Collapse
|
19
|
Mid-term results of ATS open pivot bileaflet mechanical prosthetic heart valve. Ann Thorac Cardiovasc Surg 2000; 6:34-8. [PMID: 10748357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
Abstract
We investigated mid-term results of the patients with an ATS bileaflet valve in our institution. In the past 6 years, 69 patients received valve replacement with an ATS valve. We assessed the changes of serum lactate dehydrogenase (LDH) level in the hospital, and the valve's closing sound. The serum LDH level had almost normalized one week postoperatively and they have maintained normal levels since then. According to the questionnaire about the valvular sound at a random period after surgery, it was unnoticeable in 61 (88.4%) of the patients with ATS valve. In the 8 patients (12.6%) who recognized the valve sound, 7 of them were reoperation cases. As to the frequency analysis for the valve's closing sound, the sound peak was indicated at around 1.2 kHz in the patients with ATS valves. In patients with St. Jude Medical (SJM) valves, it appeared not only around 1.2 kHz but also around 2 to 7 kHz. Postoperative cerebral infarction was complicated in one patient. Mortality occurred in 4 (5.7%) of the patients with ATS valves. The follow up periods were from one to 66 months. Thromboembolic event free and actuarial survival rate in the patients with ATS valves were 98.6% and 94.2%, respectively. These results indicated that the ATS valve is considered to be a safe valve and mid-term follow-up shows excellent results in terms of the patients quality of life.
Collapse
|
20
|
Closure of calcified patent ductus arteriosus. Ann Thorac Cardiovasc Surg 2000; 6:54-6. [PMID: 10748361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
Abstract
Patent ductus arteriosus (PDA) in adults is occasionally associated with calcification and pulmonary hypertension, for which an anterior approach through a median sternotomy with cardiopulmonary bypass is often used. Sutures are placed without circulatory arrest by using a transpulmonary balloon catheter as an occluder. To secure the suture tie, we used Nélaton's catheters as tourniquets.
Collapse
|
21
|
Clinical results of coronary artery bypass grafting with use of the internal thoracic artery under low free flow conditions. J Thorac Cardiovasc Surg 2000; 119:125-9. [PMID: 10612770 DOI: 10.1016/s0022-5223(00)70226-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Even when left internal thoracic artery flow is very low, we have used the artery for grafting without any further maneuvers. In this study, we investigated the clinical results of coronary bypass surgery using the left internal thoracic artery with low free flow. METHODS A total of 163 patients were divided into 2 groups: group L (n = 43) had free flow of 20 mL/min or less and group H (n = 120) had free flow of more than 20 mL/min. We performed a comparative study on the basis of coronary angiography and pulsed Doppler echocardiography. Furthermore, 12 months' postoperative graft angiography was carried out in 11 patients from group L. RESULTS No patient had low output syndrome or perioperative myocardial infarction. One month after the operation, 3 cases of graft occlusion and 9 cases of the "string sign" were identified in group H. However, group L had no graft occlusion and only 1 case of the "string sign." The 1-month postoperative Doppler echocardiographic study showed no significant differences in the diastolic fraction of velocity time integrals and the diastolic/systolic peak velocity ratio of the grafts. In the 11 patients undergoing angiography after 1 year, graft patency was excellent. Moreover, the graft diameter was significantly larger than it was 1 month after the operation. CONCLUSION These results suggest that the left internal thoracic artery can be used for coronary artery bypass grafting even when the flow is less than 20 mL/min.
Collapse
|
22
|
Abstract
The Kyocera Gyro C1E3 centrifugal blood pump was clinically applied for a cardiopulmonary bypass (CPB) of coronary artery bypass grafting (CABG). The patient was 72-year-old male with postinfarction unstable angina. The surgery was carried out on November 20, 1998. The air inside the pump was easily and quickly removed, and its controllability was excellent. The pump flow during operation was maintained 2.2 L/m2. Total CPB time was 173 min. Perioperative parameters of hemolysis and cytotoxicity were not remarkably changed. Macroscopically and microscopically, there were no thrombi inside the pump after usage. This is the first reported case of clinical use of the Kyocera Gyro C1E3 pump.
Collapse
|
23
|
Abstract
The Gyro Pump C1E3 is a new centrifugal pump with numerous features, including a ceramic pivot bearing system, secondary vanes, and an eccentric inlet port. To evaluate its biocompatibility, antithrombogenicity, and produced hemolysis, we used the Gyro Pump during cardiopulmonary bypass (CPB) for coronary artery bypass grafting (CABG) cases to compare it with the BioMedicus pump. From September 1998 to February 1999, 30 consecutive patients underwent CABG under conventional CPB. Fifteen patients were supported by the Gyro Pump C1E3 (Group G), and the remaining 15 patients, by a BioMedicus BP-80 pump (Group B). In both groups, flow rate was equivalent. Blood samples were taken as follows: preoperative, 60 minutes after the end of the procedure, and at postoperative days (POD) 0, 1, and 2. We evaluated the plasma free hemoglobin (free Hb) as an indication of hemolysis; beta-thromboglobulin (beta-TG) and platelet factor four (PF-4) as an indication of platelet deterioration; C3, C4, CH50 for complement activation; coagulation parameters, fibrinolytic factor, thrombomodulin, nitric oxide (NO), and endothelin as an indication of endothelial deterioration. This was the first clinical sized Gyro Pump CIE3. De-airing from the pump was easily accomplished via the eccentric oblique inlet port. The system, including its console, was easily and simply controlled. Perioperative laboratory data were not markedly changed in either group with demonstrated equivalence for biocompatibility and hemolysis. After pumping, no thrombus formation or pivot wear were observed inside the pump. This atraumatic, small centrifugal pump appears well suited not only for CPB but also for circulatory support.
Collapse
|
24
|
The efficacy and mid-term results with use of gelatin resorcin formalin (GRF) glue for aortic surgery. Ann Thorac Cardiovasc Surg 1999; 5:321-5. [PMID: 10550718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023] Open
Abstract
Twenty-six patients were treated by surgical procedure for aortic diseases with use of Gelatin Resorcin Formalin (GRF) glue. They consisted of 25 cases of emergency surgery for type A acute aortic dissection (AAD) and one elective case of distal arch aneurysm. Fifteen patients had moderate to massive aortic regurgitation (AR). We applied GRF glue to adhere the false lumen. It was further applied to anastomosed stitches from the outer side of the aorta. We evaluated the intraoperative effects of it in terms of adhesion and hemostasis and postoperative aortic regurgitation. Furthermore, the mid-term survival rate was investigated. In all cases, the 2 layers were able to be adhered successfully. Furthermore, it was very easy for suturing to pass through the aortic wall, even though the aortic stump was very hard. However, in the distal arch aneurysm case, additional sutures were needed to control the bleeding from the anastomosis. In postoperative aortography, residual AR was found in only one case. Operative deaths were indicated in 3 cases (11.5%). One patient died of hepatic failure on the 9th postoperative day. The other patients died of multiple organ failure. There were 3 cases of late death. The actuarial survival rate at 35 months was 76. 9%. According to these results, we recommend that GRF glue is very effective to reinforce the diseased aortic wall and will improve long-term survival. However, it is considered that the hemostasis effect of GRF glue is not sufficient to be used on anastomosed stitches from the outer side of the aorta.
Collapse
|
25
|
Doppler features of occlusion of the internal thoracic artery due to preoperative branch embolization. JAPANESE CIRCULATION JOURNAL 1999; 63:819-21. [PMID: 10553929 DOI: 10.1253/jcj.63.819] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A 61-year-old male was referred to the surgical ward by cardiologists because of a diagnosis of unstable angina with 3-vessel disease. On preoperative left internal thoracic arteriography, a large first intercostal branch was found at the proximal portion. Selective arterial embolization of the branch of the left internal thoracic artery (LITA) was carried out preoperatively. At 2 days after embolization, the Doppler peak flow velocity and diameter of the LITA were increased and enlarged compared with before the procedure. However, a large reverse wave following after the first systolic peak flow of the LITA was newly detected after embolization. Upon operation, the LITA was found to be occluded at the 2nd intercostal space due to thrombus formation. Therefore, the right internal thoracic artery was anastomosed to the left anterior descending artery and coronary reversed saphenous vein grafts were joined to segment 4PD of the right coronary artery. The postoperative course was uneventful. There has been no previous report of an LITA branch being embolized preoperatively. It was possible to diagnose the graft problem by detecting the altered Doppler wave form of the LITA.
Collapse
|
26
|
Clinical use of Jostra Rota Flow centrifugal pump: the first case report in Japan. Ann Thorac Cardiovasc Surg 1999; 5:230-2. [PMID: 10508947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023] Open
Abstract
A Jostra Rota Flow centrifugal blood pump was clinically applied for a cardiopulmonary bypass (CPB) of an ascending aortic replacement for type A aortic dissection. The patient was a 68-year-old female with Stanford type A, DeBakey type II thrombosed aortic dissection complicated by cardiac tamponade and moderate aortic regurgitation. The surgery was carried out on December 22, 1998. The air inside the pump was easily and quickly removed, and its mode of control was excellent. The pump flow during the operation was maintained at about 2.2 l/m2. Total CPB time was 179 minutes. Macroscopically and microscopically, there were no thrombi inside the pump, after usage. The postoperative course was uneventful. The clinical use of this pump was the first case in Japan. This pump is excellent in the ease by which it's controlled due to its compact size and low weight. Furthermore, the Rota Flow console can be fully integrated in the HL-20 heart-lung machine, and these systems have pulsatile flow mode possibility. This pump is suitable not only for the main pump of CPB but also circulatory support.
Collapse
|
27
|
[A case of mitral valve replacement combined with idiopathic thrombocytopenic purpura (ITP)]. KYOBU GEKA. THE JAPANESE JOURNAL OF THORACIC SURGERY 1999; 52:573-7. [PMID: 10402788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
Abstract
We conducted mitral valve replacement (MVR) in a patient with mitral regurgitation (MR) complicated with idiopathic thrombocytopenic purpura (ITP). The patient was a 62-year-old male who was diagnosed to have grade IV MR. However, a decrease in platelet count was noted (5.6 x 10(4)/microliter) when he has admitted to this hospital for operation. After detailed examination, he was diagnosed to have ITP. Though mass intravenous infusion of gamma-globulin (400 mg/kg/day, for 5 days) was done before the operation, the treatment was not successful and splenectomy was consequently conducted. In view of the influence of invasive splenectomy, the change in platelet count was carefully observed thereafter. The count subsequently increased to reach a peak (26.9 x 10(4)/microliter) after 2 weeks from the splenectomy. MVR was conducted when the count started to decrease again after the peak. The operation was safely completed without any complication such as hemorrhage during and after the operation. Since gamma-globulin treatment and splenectomy are sometimes ineffective in ITP, it is advisable to wait an operation until the effects of these treatments are clarified.
Collapse
|
28
|
Should use of the internal thoracic artery be avoided under conditions of low free flow? Postoperative hemodynamic assessment using pulsed Doppler echocardiography. JAPANESE CIRCULATION JOURNAL 1999; 63:533-6. [PMID: 10462020 DOI: 10.1253/jcj.63.533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
There are cases in which it is thought advisable to avoid the use of the left internal thoracic artery (LITA) in coronary artery bypass grafting (CABG) due to its low free flow (FF). However, even though the LITA flow is very low, anastomosis without any further maneuvers intraluminally is recommended. The present study investigated the clinical results of CABG, using a LITA with low FF. The 60 cases of CABG were divided into 2 groups: (i) Group L (n = 23), in which LITA FF was less than 20 ml/min; and (ii) Group H (n = 37) in which it was more than 20 ml/min. A comparative study on the basis of coronary angiography and pulsed Doppler echocardiography was performed. In both groups, no LITA graft occlusion was identified, and the 'string sign' was also absent. In the LITA blood waveform, all cases exhibited a biphasic pattern with a higher mid-diastolic and a lower end-systolic component. There were no significant differences in the LITA flow diastolic peak velocity, velocity time integrals and the diastolic/systolic peak velocity ratios. These results suggest that the LITA can be used for CABG even when the free flow is less than 20 ml/min.
Collapse
|
29
|
Abstract
Recently, several types of centrifugal pumps have been widely used as the main pumps for cardiopulmonary bypass (CPB). However, according to the results of our experimental studies, after cardiogenic shock, pulsatile flow was effective in maintaining the functions and microcirculations of end organs, especially those of the liver and kidney. To estimate the effectiveness of pulsatility during CPB, cytokine and endothelin and other metabolic parameters were measured in clinical pulsatile and nonpulsatile CPB cases. From March to May 1997, CPB was performed in 18 elective cases (14 ischemic and 4 valvular disease). In 9 cases, pulsatile perfusion was achieved by the Jostra HL20, which is a newly developed CPB pump (Group P). A nonpulsatile centrifugal pump was used in 9 patients (Group NP). In both groups, as chemical and metabolic mediators, interleukin-8 (IL-8), endothelin-1 (ET-1), and plasma free hemoglobin were measured before and during CPB, and 0.5, 3, 6, 9, 18 h after weaning from CPB. This pulsatile CPB pump could be very simply and easily controlled and could easily produce pulsatile flow. There were no significant differences in CPB time (CPBT), aortic cross clamp time (ACCT), mean aortic pressure, or pump flow during CPB between the both groups. The ET-1 level of Group P was significantly (p < 0.05) lower than that of Group NP 9 h after CPB weaning. The IL-8 level of Group P also showed a lower value than that of Group NP. As for plasma free hemoglobin, there were no significant differences between the groups. These results suggested that even in conventional CPB, pulsatility was effective to reduce endothelial damage and suppress cytokine activation. It may play a important role in maintaining the functions and microcirculations of end organs during CPB.
Collapse
|
30
|
Surgical treatment of 22 cardiac myxomas: A review. Ann Thorac Cardiovasc Surg 1999; 5:146-9. [PMID: 10413759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/13/2023] Open
Abstract
Twenty-two cases of cardiac myxomas were reviewed. The patients were 8 men and 14 women ranging in age from 12 to 73 (mean: 50.8 +/- 16. 6) at operation. They suffered from dyspnea, palpitation, and cough, similar to mitral disease symptoms, and cerebral emboli in 6 patients (30%) with left atrial myxomas. Echocardiography, especially transesophageal, was useful in diagnosing cardiac tumors and location. In 20 cases, tumors were at the left atrium and at the right in 2. Left atrial myxomas were approached through a septal incision in 17 cases; a large circular incision of the biatrium was used in 3 patients with large tumors or mitral regurgitation. Left atrial myxomas were attached to the atrial septum in 17 cases, the posterior wall of the left atrium in 2, and near the posterior commissure of the mitral valve in 1. Right atrial myxomas were attached to the atrial septum in 1 and posterior wall beside the inferior vena cava in 1. Resected myxomas weighed from 10 to 90 (mean: 39.1 +/- 19.1) g. No correlation was seen between features such as neurologic symptoms, feeding artery on coronary angiography, or functional status and tumor weight. No recurrence was seen.
Collapse
|
31
|
[Effectiveness of low dose continuous infusion of alpha-hANP from the start of cardiopulmonary bypass]. KYOBU GEKA. THE JAPANESE JOURNAL OF THORACIC SURGERY 1999; 52:384-9. [PMID: 10319627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
In this study, we used alpha-human atrial natriuretic peptide (hANP) from staring on cardiopulmonary bypass and evaluated for the hemodynamics, ANP, renin activity, aldosterone, urine volume, glomerular filtration rate (GFR) and so on. The hANP decreased renin activity, aldosterone, systemic vascular resistance and increased urine volume, GFR and use of furosemide and KCL were decreased. We concluded that hANP was effective for hemodynamics, renal function and hormonal release on intra and post-operation in cardiac surgery, and low dose continuous infusion of alpha-hANP from staring on cardiopulmonary bypass will be expected as a newly application.
Collapse
|
32
|
Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation. Artif Organs 1999; 23:280-5. [PMID: 10198721 DOI: 10.1046/j.1525-1594.1999.06318.x] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
We examined a major organ function during 3 h biventricular assisted circulation after acute myocardial infarction model in the pig. In left ventricular circulation, the outflow cannula was placed in the ascending aorta and an inflow cannula through the mitral valve in the left ventricle. A pump (pulsatile group, Zeon Medical, Inc., Tokyo, Japan and nonpulsatile group, Nikkiso HPM-15, Nikkiso, Inc., Tokyo, Japan) was connected to each cannula. In right ventricular circulation, the outflow cannula was placed in the pulmonary artery and an inflow cannula in the right ventricle. The right ventricular circulation was supported by a nonpulsatile pump (Nikkiso HPM-15). The items measured were the regional blood flows of the cortex and medulla in the kidney, white matter and gray mater in brain, and liver; renal arterial flow; carotid arterial flow; portal vein flow; common hepatic arterial flow; arterial ketone body ratio (AKBR); and lactate/pyrubic acid (L/P). In the pulsatile group, the renal cortical blood flow increased, and the medulla blood flow decreased. On the other hand, in the nonpulsatile group, both regional blood flows decreased. That means that in the pulsatile assisted group intrarenal redistribution improved rather than in the nonpulsatile assisted group. In addition the liver regional blood flow, AKBR, and L/P showed significant differences between the pulsatile and nonpulsatile groups. On the other hand, the white matter and gray matter regional blood flows and carotid arterial flow did not show significant differences between the groups. The results of our study indicated that pulsatile circulation produced superior circulation in the kidney and liver, and microcirculation on the cell level was superior as well in early treatment of acute heart failure.
Collapse
|
33
|
Myocardial revascularization without cardiopulmonary bypass in patients with operative risk factors. Ann Thorac Cardiovasc Surg 1999; 5:31-5. [PMID: 10074566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2023] Open
Abstract
We have treated 7 myocardial revascularization cases with operative risk factors, using the beating heart technique without cardiopulmonary bypass. Operative risk factors included left ventricular dysfunction, calcified aorta, chronic renal failure, cerebrovascular accident, immunosupressive state and old age. The 6 males and 1 female ranged in age from 54 to 84 years (mean age 70 years). The mean number of grafts was 1.3 per patient. All were extubated within 3 hours of arrival at the intensive care unit. Inotropic catecholamin support was not necessary on postoperative days. None of our patients had perioperative myocardial infarction. Postoperative angiography showed that all grafts were patent. We have found, based on our experiences, that selected patients can safely undergo CABG without cardiopulmonary support.
Collapse
|
34
|
[A trial case of coronary bypass surgery under heart beat in a patient with severe functional disorders of kidney]. KYOBU GEKA. THE JAPANESE JOURNAL OF THORACIC SURGERY 1999; 52:129-33. [PMID: 10036873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/10/2023]
Abstract
Coronary artery bypass grafting (CABG) was performed under heart beat without conducting extracorporeal circulation in a patient with severe functional disorders of kidney, and satisfactory results were attained. The patient was a 71-year-old male with past history of severe functional disorders of kidney and cerebral infarction. He had triple-vessel disease. First, CABG was performed for the primary branches under heart beat without adopting extra-corporeal circulation, then later, percutaneous transluminal coronary angioplasty (PTCA) was performed for the residual lesions, which lead to complete revascularization without causing aggravation of cerebral infarction or functional disorders of kidney or subjective symptoms such as chest pain. CABG conducted under heart beat is less aggressive not only to myocardium but to other important organs, and is thought to be effective for patients who have severe concurrent diseases to which extracorporeal circulation is likely to entail risks. Furthermore, concurrent therapy with PTCA is thought to expand the scope of application of CABG under heart beat including the cases of multiple-vessel diseases.
Collapse
|
35
|
Spontaneous recanalization of postoperative severe graft stenosis. What is the cause and prognosis of the "string sign" in the internal thoracic artery? Ann Thorac Cardiovasc Surg 1999; 5:52-5. [PMID: 10074570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2023] Open
Abstract
A 68-year-old female with unstable angina was treated surgically. She was referred to the surgical ward by cardiologists because of a diagnosis of unstable angina with three vessel disease. On a coronary angiogram (CAG), 90% stenoses were found in the left anterior descending coronary artery (LAD), circumflex (CX), and right coronary artery (RCA). She received elective coronary artery bypass grafting (CABG), in which the left internal thoracic artery (LITA) was anastomosed to the LAD and reversed saphenous vein grafts (SVG) were made to segment 12 of the CX, and segment 4PD of the RCA, respectively. The postoperative course was uneventful, but postoperative early graftgraphy revealed distal narrowing of the LITA graft as the so-called "string sign". However, one year post surgery, the LITA string sign was not found and its patency had markedly improved on the second graftgram. It is reported that the LITA "string sign" might cause late graft occlusion. However, this LITA graft evidently enlarged the size and increased the flow of the artery in proportion to myocardial blood demand. To our knowledge, it has not been reported that an in situ LITA string sign on postoperative early graftgram has disappeared in the late phase. We hypothesize that the LITA string sign might be caused by several different factors such as flow competition, spasm, and/or technical problems. In any event, the LITA string sign does not cause graft occlusion in the late postoperative period in every case.
Collapse
|
36
|
Effects of phosphodiesterase inhibitors after coronary artery bypass grafting. JAPANESE CIRCULATION JOURNAL 1999; 63:117-22. [PMID: 10084374 DOI: 10.1253/jcj.63.117] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The aim of this study was to estimate the postoperative effects of phosphodiesterase (PDE) inhibitors (milrinone and olprinone) after coronary artery bypass grafting (CABG). To prevent hypotension caused by the PDE inhibitors, low dose of catecholamines were used concomitantly. A total of 34 elective CABG cases were tested. In 12 cases, 0.25 microg kg(-1) min(-1) of milrinone, 3 microg kg(-1) min(-1) of dobutamine (DOB) and dopamine (DOA) were used concomitantly (Group-M). In another 10 patients, 0.1 microg kg(-1) min(-1) of olprinone and the same doses of the catecholamines were infused (Group-O). As a control, the same doses of DOA and DOB only were administered in 12 patients (Group-C). When the pump flow of the cardiopulmonary bypass (CPB) decreased to half, these drugs were given in all groups. Hemodynamics were recorded before CPB, just after the operation, and 3, 6, 12, 24, 48 and 72 h after the operation. Both milrinone and olprinone increased the cardiac index and decreased systemic vascular resistance to almost the same degree. Olprinone decreased mean aortic and pulmonary artery pressures, and also significantly reduced the preload of both right and left heart compared with milrinone. Significant hypotension was not detected due to the concomitant usage of low-dose catecholamines. This concomitant usage of PDE inhibitors and catecholamines allowed easy weaning from CPB, demonstrating excellent hemodynamics after CABG. Good oxygen demand and supply balance were maintained in peripheral tissue. These results suggest that these new PDE inhibitors may be effective not only for weaning from CPB but also for post-cardiotomy cardiogenic shock.
Collapse
|
37
|
Congenital coronary artery fistula treated surgically in the right atrium and the atrial septum. Ann Thorac Cardiovasc Surg 1998; 4:359-62. [PMID: 9914467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023] Open
Abstract
Various surgical techniques have been employed according to the type of the coronary fistula. In this case, preoperative examinations by aortography and MRI revealed a coronary artery fistula which originated from a site just proximal of the RCA, ran through the interatrial septum and drained into the posterior wall of right atrium. The ratio of pulmonary to systemic blood flow (Qp/Qs) was 1. 95. During surgery, we were not able to ligate or divide the fistula on the cardiac surface because the fistulous vessel originated from the posterior aspect of the proximal RCA. After establishing a cardiopulmonary bypass, the opening of the fistula in the right atrium was closed with an autologous pericardium patch, the surface of the interatrial septum was incised and the fistula was identified. The conduit was then divided and closed in the atrial septum. The postoperative course was uneventful. This approach is able to interrupt the fistula safely without interfering with normal coronary flow. Closure of the outlet and division of the fistula itself is a recommendable method to insure interruption of fistulous communication.
Collapse
|
38
|
[Microcirculation of kidney and skin during left ventricular assisted circulation--comparative studies of pulsatile and nonpulsatile assists]. THE JAPANESE JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY : OFFICIAL PUBLICATION OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY = NIHON KYOBU GEKA GAKKAI ZASSHI 1998; 46:1239-46. [PMID: 10037830 DOI: 10.1007/bf03217910] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
We examined microcirculation of the kidney and skin over a six-hour period in an acute myocardial infarction model in pigs. The outflow cannula was placed in the ascending aorta, the inflow cannula was placed the in left atrium, and a pump was connected to each (pulsatile group, Zeon Medical pneumatic pump; nonpulsatile group, Nikkiso HPM-15). Items examined included the regional blood flow of the cortex and medulla in the kidney and skin, renal and carotid arterial flow, arterial ketone body ratio (AKBR), lactate/pyruvic acid (L/P), BUN, creatinine, and beta 2-microglobulin. After the experimental study, the major organs were removed and a pathological study was performed. The mean aortic pressure after the assist could be maintained at about 100 mmHg. There were no significant differences between the two groups in mean aortic pressure and total cardiac output. Under assisted circulation, the pulse pressure was maintained at about 15 mmHg in the nonpulsatile group and about 40 mmHg in the pulsatile group. After the assist, there were no significant differences in the carotid arterial blood flow between the two groups. However, there were significant differences between the two groups in the renal arterial, renal cortical, and regional skin blood flows. In the laboratory data, there were significant differences between the two groups in AKBR, L/P, and beta 2-microglobulin. Pathological findings on the kidney in the nonpulsatile group showed expansion of the proximal tubes, retention of red blood cells, and expansion of blood capillaries within the glomerulus. On the other hand, the pulsatile group showed almost normal formation. In the lungs, the nonpulsatile group showed edematous change in the air cells and the pulsatile group showed almost normal formation. The results of the previous and current study indicated that the pulsatile assist produced superior circulation in the kidney and peripheral organs and superior cellular metabolism in the early treatment of acute left cardiac failure. On the other hand, nonpulsatile assisted circulation was found to be ineffective in maintaining the circulation in the body, and to be potentially capable of causing irreversible damage of major organs if continuous for more than three hours. The results also indicated that pulsatility was necessary to maintain normal circulation in the peripheral organs and cellular metabolism in the early treatment of acute left cardiac failure.
Collapse
|
39
|
[Mediastinal neurilemmoma originating in the right phrenic nerve: a case report]. NIHON KOKYUKI GAKKAI ZASSHI = THE JOURNAL OF THE JAPANESE RESPIRATORY SOCIETY 1998; 36:1027-31. [PMID: 10064956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
Abstract
We report on a 31-year-old man with a mediastinal neurilemmoma originating in the right phrenic nerve. The patient was admitted because of abnormal chest X-ray shadows observed during a routine checkup. A preoperative diagnosis of bronchial cyst in the mediastinum was made. The tumor was resected by video-assisted thoracic surgery. It was 3 x 4 x 3 cm in size, weighted 15 g, and originated in the right phrenic nerve. The histopathologic diagnosis was mediastinal neurilemmoma. Only 14 cases have been reported in the Japanese literature.
Collapse
|
40
|
Post-operative effects of olprinone after coronary artery bypass grafting. Ann Thorac Cardiovasc Surg 1998; 4:340-6. [PMID: 9914463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023] Open
Abstract
The aim of this study was to test the effects of olprinone after coronary artery bypass grafting (CABG). In order to prevent hypotension caused by olprinone, low doses of catecolamines were used concomitantly. Total 22 elective CABG cases were evaluated. In all cases, moderate hypothermia and cardioplegic cardiac arrest were performed. In 10 cases, continuous intravenous 0.1 microg/kg/min of olprinone, 3 microg/kg/min of dobutamine (DOB) and dopamine (DOA) as the initial doses, were used concomitantly (Group I). As a control, the same initial doses of catecolamine (DOB and DOA) of Group I were administered in another 12 patients (Group II). When the pump flow of cardiopulmonary bypass (CPB) was decreased to half, these drugs were administered in both groups. Hemodynamics were recorded before CPB, just after the operation and 3, 6, 12, 24, 48, and 72 hours after the operation. Three hours after the operation, both mean aortic pressure (AoP) and pulmonary artery pressures (PAP) of Group I demonstrated significantly lower values than those of Group II. Cardiac index (CI) of Group I showed significantly higher values than that of Group II until 6 hours after surgery. The systemic vascular resistance index (SVRI) of Group I indicated a significantly lower value than that of Group II until 24 hours after the operation. Pulmonary capillary wedge pressure (PCWP) of Group I demonstrated a significantly lower value than that of Group II. There were no significant differences in urine output, oxygen delivery (DO2) and oxygen consumption (VO2) between both groups. Olprinone increased CI and decreased SVRI, and it showed easy weaning from CPB, demonstrating excellent hemodynamics after CABG. These results suggested that this new phosphodiesterase inhibitor may be effective for not only weaning from CPB but also post-cardiotomy cardiogenic shock.
Collapse
|
41
|
[A case of coronary arterial fistula originating from both coronary artery and draining to the right atrium]. THE JAPANESE JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY : OFFICIAL PUBLICATION OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY = NIHON KYOBU GEKA GAKKAI ZASSHI 1998; 46:1349-53. [PMID: 10037848 DOI: 10.1007/bf03217928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
We encountered a case with bilateral fistulas of coronary arteries into the right atrium, a rare cardiac anomaly. The case was a 17-year-old woman, who visited our hospital at the age of 11 because of fever. At that time, the patient was diagnosed as having a left coronary artery-right atrial fistula through cardiac catheterization (CAG). When the patient developed staphylococcus infected endocarditis at the age of 16, a thick fistula of the coronary artery, directly running from the deformed left coronary arterial sinus, a fistula of the left circumflex branch, and also a fistula of the right coronary artery into the right atrium were detected by CAG. The outlets of these fistulas were closed from the inside of the right atrium under artificial cardiopulmonary circulation and cardiac arrest, and each fistula was ligated at the outside of cardiac chambers. At that time, we took particular care that any branch of the sinuatrial node was not injured. Although all fistulas were confirmed to be closed by postoperative CAG, and no evidence of ischemia was detected by myocardial scintigraphy, deformity of the left coronary arterial sinus remained, requiring further follow up.
Collapse
|
42
|
Effects of concomitant usage of milrinone and catecholamine for weaning from cardiopulmonary bypass. THE JAPANESE JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY : OFFICIAL PUBLICATION OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY = NIHON KYOBU GEKA GAKKAI ZASSHI 1998; 46:803-9. [PMID: 9796277 DOI: 10.1007/bf03217826] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
To estimate the effectiveness of concomitant usage of milrinone and catecholamine for weaning from cardiopulmonary bypass (CPB), a clinical study was made, in elective coronary artery bypass grafting (CABG) cases. 24 consecutive patients underwent elective CABG in our institute. In all cases, moderate hypothermia and cardioplegic(St. Thomas solution) cardiac arrest were performed. In 12 cases, continuous intravenous 0.25 microgram/kg/min of milrinone, 3 micrograms/kg/min of dobutamine (DOB) and dopamine (DOA) as the initial doses, were used concomitantly as inotropic agents (Group-I). The same initial doses of catecholamine (DOB and DOA) as the Group-I were administered in another 12 patients (Group-II). When the pump flow of CPB decreased to a half, these drugs were administered in both groups. Hemodynamic data were measured before CPB, just after operation, 3, 6, 12, 24, 48, and 72 hours after operation. There were no significant differences in aortic and pulmonary artery pressure between both groups. However, cardiac index (CI) of the Group-I demonstrated significantly (p < 0.01) higher values than that of Group-II until 24 hours after surgery. Systemic vascular resistance index (SVRI) of the Group-I demonstrated significantly (p < 0.01) lower value than that of Group-II from 3 to 12 hours after operation. There were no significant differences in oxygen delivery (DO2) and oxygen consumption (VO2) between both groups. These results suggested that concomitant usage of milrinone and low dose catecholamine increased CI and decreased SVRI, and made weaning from CPB very easy, demonstrating excellent hemodynamics. This high potential phosphodiesterase inhibitor may be suitable for not only weaning from CPB but also post-cardiotomy cardiogenic shock.
Collapse
|
43
|
Abstract
Minimally invasive coronary artery bypass grafting (CABG) aims to avoid cardiopulmonary bypass and take maximum advantage of a smaller incision. Minimally invasive direct coronary artery bypass (MIDCAB) surgery is performed on selected arteries of the beating heart under direct vision through a choice of small incisions. Short-term results show good patency rates and a dramatic impact in terms of shorter hospital stays and cost effectiveness. The procedure is also being used increasingly in Japan. However, valid concerns have been raised about the quality of the anastomosis fashioned on a beating heart with pharmacologic bradycardia, and the long-term result of this technique is still questionable. The combined use of circulatory assist devices and mechanical stabilizing devices will be expected to expand access to coronary arteries by allowing for decompression of the left ventricle, permitting retraction and rotation of the heart, and hopefully further improvement of the results. Less invasive coronary surgery should be proven to be as effective and safe as conventional CABG before widespread adoption.
Collapse
|
44
|
Macroscopic aspects of cloth-covered Starr-Edwards prostheses at reoperation: what the precursory valve teaches us. THE JOURNAL OF HEART VALVE DISEASE 1998; 7:556-60. [PMID: 9793856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
BACKGROUND AND AIMS OF THE STUDY Cloth-covered Starr-Edwards ball valves were the first choice in prosthetic substitution at the authors' institution between June 1968 and March 1977. This study investigated, retrospectively, macroscopic aspects of the prostheses at reoperation. METHODS Among 59 survivors who underwent isolated aortic or mitral valve replacement, 12 required reoperation for valve dysfunction (five aortic valve replacements, seven mitral valve replacements). Reoperation was necessitated by valvular endocarditis, paravalvular leak, hemolysis, thromboembolism, orifice stenosis attributable to pannus, and inappropriate sizing related to growth and thrombus. The mean time to reoperation was 11.7 +/- 6.2 years after initial surgery (range: 2 years 4 months to 21 years 8 months). RESULTS Marked cloth wear was observed in all aortic prostheses, but only slight wear in mitral valves. Pannus formation was observed around the orifice in both aortic and mitral prostheses, but strut cloth was not extensively covered by autologous tissue. In mitral valves, strut cloth was only slightly worn and less loose than that of the aortic valve. These changes notably affected prosthetic valve function, the most significant problem in mitral prostheses being thrombus (four of seven valves). CONCLUSIONS Pannus formation and thrombus caused by the reaction of the patient's tissues remain major problems in the use of artificial valves, and require further work for their improvement.
Collapse
|
45
|
Mechanical cardiac assistance. Ann Thorac Cardiovasc Surg 1998; 4:178-87. [PMID: 9738117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
In our institute, we have intensively introduced both pulsatile and non-pulsatile mechanical cardiac assist devices, such as the pneumatic ventricular assist device (VAD) and percutaneous cardiopulmonary support (PCPS), using a centrifugal pump. From various kinds of clinical views, these cases were estimated and evaluated retrospectively according to the weaning results, long-term survival rate and cause of death. Based upon our experiences and clinical results, an alternate strategy of mechanical cardiac assistance for severe heart failure is suggested as follows. In the case of post-cardiotomy cardiogenic shock or low output syndrome, PCPS system should be applied firstly under intra-aortic balloon pumping (IABP) assist for a maximum of 2-3 days. If the native cardiac function does not recover and more long-term support is needed, several types of VAD, which are more powerful and durable devices should be introduced, according to end organ function and expected support duration. In order to obtain better clinical results, we have to select an appropriate device depending on the limited availability of supporting duration. Generally speaking, centrifugal pumps can support in short-term duration, while pulsatile devices cover the broad spectrum of the supporting period. Pneumatic VADs can cover short-term to long-term support up to a year, and electric VADs can cover over 1 year, and can be used as a bridge to heart transplantation.
Collapse
|
46
|
Left atrial myxoma with an atrial septal defect: a case report and review of the literature. Ann Thorac Cardiovasc Surg 1998; 4:133-7. [PMID: 9660910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
We report a case of a 49 year-old Japanese woman with a left atrial myxoma complicated by an atrial septal defect diagnosed intraoperatively, which was classified as in secundum defect and was 28x110 mm in diameter. The tumor, which was attached by a pedicle to the posterior wall of the left atrium near the posterior commissure of the mitral valve, was removed together with a small portion of the left atrial wall. The postoperative course was uneventful. The pathologic findings were consistent with the diagnosis of myxoma. Since the defect was functionally canceled by the myxoma, the diagnosis of an atrial septal defect was not confirmed preoperatively even by color Doppler echocardiography and cardiac catheterization. Tumor embolization is one of the critical complications of myxoma. Fortunately, she didn't suffer from either systemic or pulmonary emboli. During surgery of myxoma with atrial septal defect, careful manipulation is needed, especially at caval cannulation so as not to damage the tumor directly. In the cases with atrial septal defect or patent foramen ovale, myxomas are generally situated on the interatrial septum. However, in this case the tumor was located on the posterior wall of the left atrium.
Collapse
|
47
|
Abstract
In recent years, several types of centrifugal pumps have been widely used as the main pumps for cardiopulmonary bypass (CPB) and postcardiotomy cardiac support. From April 1990 to March 1997, a percutaneous cardiopulmonary support (PCPS) system was used in 20 patients with an average age of 58 years (13 males and 7 females). They comprised 11 ischemic, 6 valvular, 2 aortic, and 1 congenital heart disease patients. Our PCPS system consists of a centrifugal pump (BioMedicus BP-80), an oxygenator, and a reservoir. The entire blood contacting surface, including that of the thin wall cannulas, is coated by heparin bonded materials. As a result of this new technology, this system can be used for the long term without systemic heparinization. No major critical thrombi were revealed inside the pumps or circuits. Of the 20 patients, 7 (35%) (Group 1) could be weaned from PCPS, and the remaining 13 (Group 2) could not. In Group 1 although 2 patients suffered from renal failure and pneumonia, respectively, both were discharged from our hospital. The long-term survival rate was 35%. In Group 2 cerebral vascular damage was recognized in 3 patients, renal failure in 4, multiple system organ failure in 4, bleeding in 2, arrhythmia in 1, and leg ischemia in 2. Pulse pressure was significantly elevated due to the recovery of the native heart in Group 1, 2 days after support. However, in Group 2, it did not elevate, and the left ventricular ejection fraction was less than 30%, associated with high left atrial pressure. In conclusion, this heparin coated PCPS system was very simple and easy to control. It demonstrated long-term biocompatibility and was very effective in recovering deteriorated cardiac function. Quicker application of this system can play an important role in preventing severe complications and obtaining better clinical results. If long-term support is necessary, a ventricular assist device (VAD), which is more powerful, durable, and biocompatible, has to be applied instead of PCPS.
Collapse
|
48
|
Coronary artery surgery results 1996. Ann Thorac Cardiovasc Surg 1998; 4:103-6. [PMID: 9577008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
This survey on ischemic heart disease surgery began in 1974 and has continued to report the current status of surgical treatment in Japan. Coronary artery bypass grafting (CABG) has increased markedly and surgical results have become increasingly favorable. This report describes CABG and surgery for postinfarction complications in 1996, including the first investigation on CABG without cardiopulmonary bypass (off-pump CABG) and minimally invasive direct coronary artery bypass grafting (MIDCAB).
Collapse
|
49
|
Abstract
Interrupted aortic arch type A with aortopulmonary window was diagnosed in a 12-day-old neonate. A successful one-stage repair was undertaken through a midline sternotomy without circulatory arrest. The aortopulmonary window was closed through the anterior wall of communication between ascending aorta and main pulmonary artery with a patch. Position of the arterial cannula was changed during the repair, which made it possible to mobilize and expose the aortic arch for the completion of direct anastomosis.
Collapse
|
50
|
[A correlation between atrial natriuretic peptide, brain natriuretic peptide, and perioperative cardiac and renal functions in open heart surgery]. [ZASSHI] [JOURNAL]. NIHON KYOBU GEKA GAKKAI 1997; 45:1797-802. [PMID: 9430955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) are homeostatic hormones secreted from the human heart which protect both cardiac and the renal function. It is well known that these hormones increase in patients along with increases in the severity of congestive heart failure or acute myocardial infarction. However, as yet there are no reports in the literature on changes of the secreted level of ANP or BNP in surgical patients undergoing cardiopulmonary bypass (CPB). We evaluated the relationship between ANP, BNP, and perioperative cardiac and renal functions in patients with heart failure caused by CPB. We selected 45 patients of elective open heart surgery. We measured plasma level of ANP in all 45 cases, and BNP in 18 cases at preoperation, postoperation, and postoperatively three days after, respectively. At the same time, the cardiac index (CI) was measured. These cases were divided into the following groups. Group A1 (n = 23): cases in which the preoperative ANP was less than 40 pg/ ml. Group A2 (n = 22): cases in which the preoperative ANP was more than 40. Group B1 (n = 8): cases in which the preoperative BNP is increased to the level of 5 times as mach as the normal level. Group B2 (n = 8): cases in which the preoperative BNP is increased to the level of 5 times as much as the normal level. Group B2 (n = 10): cases in which the preoperative BNP was more than that of 10 times as mach as normal level. We then carried out a comparative study of the perioperative cardiac and renal functions in group A1 and A2, and group B1 and B2, respectively. In the terms of preoperative cardiac and renal function, there were no significant differences between groups A1 and A2, and there were no significant differences in urinary volume during CPB or post operative CI. However, the urinary volume during CPB of group B1 was significantly more than that of B2. Furthermore, the incidence of postoperative CI in group B1. Furthermore, the incidence of postoperative CI in group B1 was significantly higher than in B2. The preoperative and post operative third day BNP level had significant negative correlations with postoperative CI and postoperative third day CI, respectively (r = -0.641, -0.514, p = 0.008, 0.012). The postoperative ANP and BNP levels tend to a mean level roughly similar to one another because of the easing of cardiac stress by surgery and postoperative management. According to these results and several instances in the literature, a preoperative high BNP is considered to suggest a potential perioperative risk for cardiac and renal function. We conclude that determination of the plasma BNP level can be helpful for decisions related to CPB flow and measures taken to enhance cardiac and renal protection during surgery, and therefore is a useful reference for perioperative management.
Collapse
|