1
|
[Analysis of clinical data of necrotizing fasciitis secondary to intestinal fistulas and screening the mortality risk factors]. ZHONGHUA SHAO SHANG YU CHUANG MIAN XIU FU ZA ZHI 2024; 40:141-150. [PMID: 38418175 DOI: 10.3760/cma.j.cn501225-20230923-00088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 03/01/2024]
Abstract
Objective: To analyze the clinical data and to screen the mortality risk factors of necrotizing fasciitis (NF) secondary to intestinal fistulas (NFsIF). Methods: This study was a retrospective observational study. The data of all NFsIF cases who met the inclusion criteria and were admitted into Shandong Provincial Hospital Affiliated to Shandong First Medical University (hereinafter referred to as our unit) from January 2000 to October 2023, and in PubMed, Web of Science, Scopus, China National Knowledge Infrastructure, and Chinese Medical Journal Network databases from its establishment to October 2023 were retrieved and screened. Based on clinical outcomes, the cases were divided into survival group (47 males and 24 females) and death group (16 males and 7 females), and the mortality rate was calculated. Clinical data of patients in the two groups including age, underlying diseases (most related to NF), symptom duration before presentation, white blood cell count, causes of NF, signs of peritonitis, scope of NF involvement, and intestinal management and wound management measures were compared and analyzed to screen the risk factors of death in 94 patients with NFsIF. Results: A total of 94 valid cases were collected, including 90 patients reported in the literature and 4 patients admitted to our unit, with the mortality rate of patients being 24.5% (23/94). Univariate analysis showed that there were no statistically significant differences in age, underlying diseases, symptom duration before presentation, white blood cell count, causes of NF, signs of peritonitis, scope of NF involvement between patients in the two groups (P>0.05); there were statistically significant differences in intestinal treatment and wound treatment between the two groups (with χ2 values of 17.97 and 8.33, respectively, P<0.05). Multivariate logistic regression analysis showed that both intestinal treatment measures and wound treatments measures were independent risk factors for death in 94 NFsIF patients, among which first-stage colostomy+late-stage reconstruction and negative presssure therapy had higher protective effects (with odds ratios of 0.05 and 0.27, respectively, 95% confidence intervals of 0.01-0.33 and 0.08-0.88, respectively, P<0.05). Conclusions: The mortality risk of patients with NFsIF is high. Based on comprehensive treatments, active intestinal and wound treatment may be the key to avoid death, with first-stage colostomy+late-stage reconstruction and negative pressure therapy having higher protective effects.
Collapse
|
2
|
[Application effect of the joint nasogastric tube for pairing overlap guiding tube (JNT) in esophagojejunostomy]. ZHONGHUA WEI CHANG WAI KE ZA ZHI = CHINESE JOURNAL OF GASTROINTESTINAL SURGERY 2023; 26:986-989. [PMID: 37849270 DOI: 10.3760/cma.j.cn441530-20230105-00003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 10/19/2023]
|
3
|
Turning whispering-gallery-mode responses through Fano interferences in coupled all-dielectric block-disk cavities. OPTICS EXPRESS 2023; 31:29380-29391. [PMID: 37710739 DOI: 10.1364/oe.500562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 08/11/2023] [Indexed: 09/16/2023]
Abstract
Here, we theoretically demonstrate a strategy for efficiently turning whispering-gallery-mode (WGM) responses of a subwavelength dielectric disk through their near-field couplings with common low-order electromagnetic resonances of a dielectric block. Both simulations and an analytical coupled oscillator model show that the couplings are Fano interferences between dark high-quality WGMs and bright modes of the block. The responses of a WGM in the coupled system are highly dependent on the strengths and the relative phases of the block modes, the coupling strength, and the decay rate of the WGM. The WGM responses of coupled systems can exceed that of the individual disk. In addition, such a configuration will also facilitate the excitation of WGMs by a normal incident plane wave in experiments. These results could enable new applications for enhancing light-matter interactions.
Collapse
|
4
|
Plasma position measurements by O-mode and X-mode reflectometry systems in tokamak plasmas. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:063505. [PMID: 37862534 DOI: 10.1063/5.0140390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 06/07/2023] [Indexed: 10/22/2023]
Abstract
Plasma Position Reflectometry (PPR) is planned to provide plasma position and shape information for plasma operation in future fusion reactors. Its primary function is to calibrate the drift of the magnetic signals due to the integral nature of magnetic measurement. Here, we attempt to measure plasma position using ordinary mode (O-mode) and extraordinary mode (X-mode) reflectometry systems on two tokamaks. A new physical model based on the phase shift is proposed to deduce the relative movement of the cut-off layer without density inversion. We demonstrate the plasma position measurements by absolute measurement from density profile inversion and relative measurement from phase shift. The combination of X-mode and O-mode reflectometers can minimize the limitations of single polarization reflectometry and further increase the accuracy of plasma position measurement. These results could provide an important technical basis for the further development of a real-time control system based on PPR.
Collapse
|
5
|
[Identification of metabolic biomarkers associated with the onset of type 2 diabetes based on a nested case-control study]. ZHONGHUA YU FANG YI XUE ZA ZHI [CHINESE JOURNAL OF PREVENTIVE MEDICINE] 2022; 56:1784-1788. [PMID: 36536566 DOI: 10.3760/cma.j.cn112150-20220315-00239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Objective: To explore metabolic biomarkers associated with the onset of type 2 diabetes. Methods: Cluster random sampling method was used to select 10 867 local residents aged ≥ 20 years in Liangxi district of Wuxi City, Jiangsu Province in 2007. The baseline survey and physical examination were conducted to collect participants' information, including demographic characteristics, behavior and lifestyles, disease history, family history of diabetes, height, weight, waist circumference and blood pressure, etc. Blood samples were collected and biochemical indexes (high density lipoprotein cholesterol, total cholesterol, triglyceride, fasting blood glucose, etc.) were tested. By June 30, 2020, 220 newly diagnosed patients with type 2 diabetes during the follow-up were selected as cases, and 220 healthy individuals were matched as controls with age (±5 years) and the same sex. High performance liquid chromatography mass spectrometer was used to detect and identify metabolites in serum samples of two groups at baseline. Lasso regression and multivariate conditional logistic regression were used to explore the metabolites associated with the onset of type 2 diabetes. Results: The age of participants at baseline was (53±7) years, and 41.82% were male. 25 out of 1 579 metabolites were selected to be potentially associated with the onset of type 2 diabetes in the lasso regression model. The multivariable conditional logistic regression analysis showed that only 7-Methylxanthine had an independent effect on type 2 diabetes (P=0.019). The area under the receiver operating characteristic curve (AUC) (95%CI) of the prediction model of type 2 diabetes based on traditional risk factors was 0.80 (0.76-0.85). After the 7-methylxanthine in the model, the AUC (95%CI) increased to 0.92 (0.89-0.95) (P<0.001). From the second year, 7-methylxanthine could improve the prediction performance (P=0.007). Conclusion: The level of 7-methylxanthine is related to the onset of type 2 diabetes, and can be used as a biomarker to predict its incidence risk.
Collapse
|
6
|
[Effects of low-dose photodynamic therapy on the function of human adipose mesenchymal stem cells and its mechanism]. ZHONGHUA SHAO SHANG YU CHUANG MIAN XIU FU ZA ZHI 2022; 38:830-838. [PMID: 36177587 DOI: 10.3760/cma.j.cn501225-20220325-00092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Objective: To investigate the effects of low-dose photodynamic therapy on the proliferation, regulation, and secretion functions of human adipose mesenchymal stem cells (ADSCs) and the related mechanism, so as to explore a new method for the repair of chronic wounds. Methods: The experimental research methods were adopted. From February to April 2021, 10 patients (5 males and 5 females, aged 23 to 47 years) who underwent cutaneous surgery in the Department of Dermatology of the First Affiliated Hospital of Army Medical University (the Third Military Medical University) donated postoperative waste adipose tissue. The cells were extracted from the adipose tissue and the phenotype was identified. Three batches of ADSCs were taken, with each batch of cells being divided into normal control group with conventional culture only, photosensitizer alone group with conventional culture after being treated with Hemoporfin, irradiation alone group with conventional culture after being treated with red light irradiation, and photosensitizer+irradiation group with conventional culture after being treated with Hemoporfin and red light irradiation, with sample number of 3 in each group. At culture hour of 24 after the treatment of the first and second batches of cells, the ADSC proliferation level was evaluated by 5-ethynyl-2'-deoxyuridine staining method and the migration percentage of HaCaT cells cocultured with ADSCs was detected by Transwell experiment, respectively. On culture day of 7 after the treatment of the third batch of cells, the extracellular matrix protein expression of ADSCs was detected by immunofluorescence method. The ADSCs were divided into 0 min post-photodynamic therapy group, 15 min post-photodynamic therapy group, 30 min post-photodynamic therapy group, and 60 min post-photodynamic therapy group, with 3 wells in each group. Western blotting was used to detect the protein expressions and calculate the phosphorylated mammalian target of rapamycin complex (p-mTOR)/mammalian target of rapamycin (mTOR), phosphorylated p70 ribosomal protein S6 kinase (p-p70 S6K)/p70 ribosomal protein S6 kinase (p70 S6K) ratio at the corresponding time points after photodynamic therapy. Two batches of ADSCs were taken, and each batch was divided into normal control group, photodynamic therapy alone group, and photodynamic therapy+rapamycin group, with 3 wells in each group. At culture minute of 15 after the treatment, p-mTOR/mTOR and p-p70 S6K/p70 S6K ratios of cells from the first batch were calculated and detected as before. On culture day of 7 after the treatment, extracellular matrix protein expression of cells from the second batch was detected as before. Data were statistically analyzed with one-way analysis of variance and least significant difference test. Results: After 12 d of culture, the cells were verified as ADSCs. At culture hour of 24 after the treatment, the ADSC proliferation level ((4.0±1.0)% and (4.1±0.4)%, respectively) and HaCaT cell migration percentages (1.17±0.14 and 1.13±0.12, respectively) in photosensitizer alone group and irradiation alone group were similar to those of normal control group ((3.7±0.6)% and 1.00±0.16, respectively, P>0.05), and were significantly lower than those of photosensitizer+irradiation group ((34.2±7.0)% and 2.55±0.13, respectively, P<0.01). On culture day of 7 after the treatment, compared with those in normal control group, the expression of collagen Ⅲ in ADSCs of photosensitizer alone group was significantly increased (P<0.05), and the expressions of collagen Ⅰ and collagen Ⅲ in ADSCs of irradiation alone group were significantly increased (P<0.01). Compared with those in photosensitizer alone group and irradiation alone group, the expressions of collagen Ⅰ, collagen Ⅲ, and fibronectin of ADSCs in photosensitizer+irradiation group were significantly increased (P<0.01). Compared with those in 0 min post-photodynamic therapy group, the ratios of p-mTOR/mTOR and p-p70 S6K/p70 S6K of ADSCs in 15 min post-photodynamic therapy group were significantly increased (P<0.01), the ratios of p-p70 S6K/p70 S6K of ADSCs in 30 min post-photodynamic therapy group and 60 min post-photodynamic therapy group were both significantly increased (P<0.01). At culture minute of 15 after the treatment, compared with those in normal control group, the ratios of p-mTOR/mTOR and p-p70 S6K/p70 S6K of ADSCs in photodynamic therapy alone group were significantly increased (P<0.05 or P<0.01). Compared with those in photodynamic therapy alone group, the ratios of p-mTOR/mTOR and p-p70 S6K/p70 S6K of ADSCs in photodynamic therapy+rapamycin group were significantly decreased (P<0.05). On culture day of 7 after the treatment, compared with those in normal control group, the expressions of collagen Ⅰ, collagen Ⅲ, and fibronectin of ADSCs in photodynamic therapy alone group were significantly increased (P<0.01). Compared with those in photodynamic therapy alone group, the expressions of collagen Ⅰ, collagen Ⅲ, and fibronectin of ADSCs in photodynamic therapy+rapamycin group were significantly decreased (P<0.01). Conclusions: Low-dose photodynamic therapy can promote the proliferation of ADSCs, improve the ability of ADSCs to regulate the migration of HaCaT cells, and enhance the secretion of extracellular matrix protein by rapidly activating mTOR signaling pathway.
Collapse
|
7
|
Polarization-perceptual anisotropic two-dimensional ReS 2 neuro-transistor with reconfigurable neuromorphic vision. MATERIALS HORIZONS 2022; 9:1448-1459. [PMID: 35234765 DOI: 10.1039/d1mh02036f] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Polarization is a common and unique phenomenon in nature, which reveals more camouflage features of objects. However, current polarization-perceptual devices based on conventional physical architectures face enormous challenges for high-performance computation due to the traditional von Neumann bottleneck. In this work, a novel polarization-perceptual neuro-transistor with reconfigurable anisotropic vision is proposed based on a two-dimensional ReS2 phototransistor. The device exhibits excellent photodetection ability and superior polarization sensitivity due to its direct band gap semiconductor property and strong anisotropic crystal structure, respectively. The fascinating polarization-sensitive neuromorphic behavior, such as polarization memory consolidation and reconfigurable visual imaging, are successfully realized. In particular, the regulated polarization responsivity and dichroic ratio are successfully emulated through our artificial compound eyes. More importantly, two intriguing polarization-perceptual applications for polarized navigation with reconfigurable adaptive learning abilities and three-dimensional visual polarization imaging are also experimentally demonstrated. The proposed device may provide a promising opportunity for future polarization perception systems in intelligent humanoid robots and autonomous vehicles.
Collapse
|
8
|
Strong couplings between magnetic quantum emitters and subwavelength all-dielectric resonators with whispering gallery modes. OPTICS EXPRESS 2021; 29:26028-26038. [PMID: 34614916 DOI: 10.1364/oe.434586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 07/23/2021] [Indexed: 06/13/2023]
Abstract
Here we theoretically investigate the coherent interactions between the quantum emitters with magnetic dipole transitions and subwavelength all-dielectric resonators of whispering gallery modes (WGMs). We extend a semi-analytical method which can efficiently calculate the far-field spectrum of a general hybrid system. Then, a subwavelength sphere with refractive index around n = 3.5 is chosen as the dielectric resonator. Due to the high magnetic field enhancements of the WGMs of the sphere, strong couplings between magnetic quantum emitters and subwavelength WGMs can occur, where a clear Rabi splitting appears on the extinction spectrum of the hybrid system. The match between the relaxation times of the WGMs and emitters are important to efficiently achieve a strong enough coupling. The other parameters including the order of a WGM, the radius, the refractive index, the transition dipole moment and excitation intensity are also important factors that can affect the couplings. Our results pave the way for strong interactions between light and magnetic emitters mediated by subwavelength all-dielectric resonators.
Collapse
|
9
|
A remote gain controlled and polarization angle tunable Doppler backward scattering reflectometer. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:063513. [PMID: 34243534 DOI: 10.1063/5.0043676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Accepted: 05/15/2021] [Indexed: 06/13/2023]
Abstract
Remote control of the diagnostic systems is the basic requirement for the high performance plasma operation in a fusion device. This work presents the development of the remote control system for the multichannel Doppler backward scattering (DBS) reflectometers. It includes a remote controlled quasi-optical system and a remote intermediate frequency (IF) amplifier gain control system. The quasi-optical system contains a rotational polarizer, its polarization angle is tunable through a remote controlled motor, and it could combine the microwave beams with a wide frequency range into one focused beam. The remote IF gain control system utilizes the digital microcontroller (MCU) technique to regulate the signal amplitude for each signal channel. The gain parameters of amplifiers are adjustable, and the feedback of working status in the IF system will be sent to MCU in real time for safe operation. The gain parameters could be controlled either by the Ethernet remote way or directly through the local control interface on the system. Preliminary experimental results show the effectiveness of the remote controlled multichannel DBS system.
Collapse
|
10
|
The key aroma compounds and sensory characteristics of commercial Cheddar cheeses. J Dairy Sci 2021; 104:7555-7571. [PMID: 33814151 DOI: 10.3168/jds.2020-19992] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 02/17/2021] [Indexed: 11/19/2022]
Abstract
To study the key aroma components and flavor profile differences of Cheddar cheese with different maturity and from different countries, the flavor components of 25 imported commercial Cheddar cheese samples in the China market were determined by gas chromatography-mass spectrometry. The quality and quantity of 40 flavor compounds were analyzed by gas chromatography-olfactometry among 71 aroma compounds determined by gas chromatography-mass spectrometry. Combined with odor activity value calculation, principal component analysis (PCA) was conducted to analyze the relationship among 26 flavor compounds with odor activity values >1 and the maturity of Cheddar cheese. The PCA results showed significant differences between the group of mild Cheddar cheese and the groups of medium Cheddar cheese and mature Cheddar cheese, and no significant differences were observed between medium Cheddar cheese and mature Cheddar cheese. According to the results of PCA and consumers' preference test, representative Cheddar cheese samples with different ripening times were selected for the flavor profile analysis. Partial least squares regression analysis was conducted to obtain the relationship between sensory properties and flavor compounds of different Cheddar cheeses. Based on partial least squares regression analysis, 1-octen-3-one, hexanal, acetic acid, 3-methylindole, and acetoin were positively correlated with milky, sour, and yogurt of mild Cheddar cheese. Dimethyl trisulfide, phenylacetaldehyde, ethyl caproate, octanoic acid, and furaneol and other compounds were positively correlated with fruity, caramel, rancid, and nutty notes of the medium and mature Cheddar cheeses.
Collapse
|
11
|
Development of the gas puffing imaging diagnostic on J-TEXT tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:043503. [PMID: 34243373 DOI: 10.1063/5.0040988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 03/11/2021] [Indexed: 06/13/2023]
Abstract
Edge turbulence is important for plasma confinement, so the gas puffing imaging (GPI) diagnostic was proposed on the J-TEXT tokamak for the two-dimensional measurement of turbulence in the edge region. GPI is a diagnostic of plasma turbulence that uses a puff of neutral gas at the plasma edge to increase the local visible light emission for improved space-time resolution of plasma fluctuations. Considering the conditions of J-TEXT, the observation area is 21° away from the position of the optical system in the toroidal direction, and the observation area is 10 cm × 10 cm inside and outside the last closed flux surface. To have a lower divergence of the gas flow, the gas puff nozzle is specially designed. An interface has been developed for operation. To photograph the line radiation generated by the neutral gas cloud along the magnetic field lines, the optical system is designed. It is composed of a quartz glass, mirrors, commercial lenses, filters, and high-speed cameras. The high-speed camera can capture the line radiation with a speed up to 180 000 frames/s with 256 pixels × 256 pixels and an exposure time of 5 µs. In a recent experiment, the new GPI diagnostic has obtained some preliminary pictures.
Collapse
|
12
|
[Probability of premature mortality caused by four major non-communicable diseases and its impact on life expectancy in Wuxi, 2008-2018]. ZHONGHUA LIU XING BING XUE ZA ZHI = ZHONGHUA LIUXINGBINGXUE ZAZHI 2021; 42:291-296. [PMID: 33626618 DOI: 10.3760/cma.j.cn112338-20200403-00506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To analyze the trend of premature death of non-communicable diseases (NCDs) in Wuxi from 2008 to 2018 and evaluate the influence of premature mortality probability caused by four main NCDs on life expectancy. Methods: Based on the mortality data collected by Wuxi Mortality Registration System and the population data collected by Wuxi Public Security Bureau during 2008-2018, this study analyzes the trend of the probability of premature death on malignant tumors, cardiovascular and cerebrovascular diseases, chronic respiratory diseases, and diabetes. The impact on life expectancy was analyzed by using the methods of abridged life table, Joinpoint regression, and life expectancy contribution decomposition. Results: From 2008 to 2018, the total probability of premature death of four main NCDs in Wuxi were declined consistently from 11.25% to 9.25% (AAPC = -2.0%, 95%CI: -2.6--1.5), higher in female (from 7.74% to 5.91%) than that in male (from 14.49% to 12.51%). The Wuxi resident's life expectancy increased by 1.86 years (from 78.66 to 80.52 years), in males and 1.26 years (from 83.85 to 85.11 years) in females, respectively. The decline of premature death of malignant tumors, cardiovascular and cerebrovascular diseases and chronic respiratory system diseases had a positive contribution to life expectancy, which contributed 0.34 years (23.90%), 0.15 years (10.50%), and 0.03 years (2.36%) to the life expectancy growth, respectively. Among which, premature death of cardiovascular and cerebrovascular diseases in men aged 40-55y had a negative contribution to life expectancy (-0.04 years). The probability of premature death of males with diabetes was on the rise (AAPC = 7.1%, 95%CI: 2.8-11.6), which negatively contributed to life expectancy for both males and females, reducing life expectancy by 0.03 years (-2.14%) in Wuxi. Conclusion: The premature death probability of four main NCDs in Wuxi declined consistently from 2008 to 2018, which played a positive role in the growth of life expectancy. Compared with females, males had a higher premature death probability and a slower rate of decline. More intervention and health management of premature male death on cardiovascular and cerebrovascular diseases and diabetes should be conducted to improve life expectancy further.
Collapse
|
13
|
Development of a tunable multi-channel Doppler reflectometer on J-TEXT tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:033545. [PMID: 33820104 DOI: 10.1063/5.0040915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 03/03/2021] [Indexed: 06/12/2023]
Abstract
Doppler reflectometer is a powerful diagnostic tool to study the turbulence for tokamak plasmas. It can provide information on the density fluctuation, the poloidal rotation, the radial electric field, its shear, etc. A tunable multi-channel V-band (50-75 GHz) Doppler reflectometer system has been developed on the J-TEXT tokamak for the measurement under various toroidal magnetic fields. A universal serial bus controlled synthesizer is used as a source that can adjust the probing frequency remotely. This Doppler reflectometer can measure the plasma in 0.3 < ρ < 1 . Its radial resolution is <2 cm, and k⊥ is ∼ 4-12 cm-1. Based on the Doppler reflectometer, the perpendicular turbulence propagation velocity, the profile of the radial electric field, the geodesic acoustic mode, and some other phenomena have been observed on J-TEXT.
Collapse
|
14
|
Spatial and temporal variability of methane emissions from cascading reservoirs in the Upper Mekong River. WATER RESEARCH 2020; 186:116319. [PMID: 32846383 DOI: 10.1016/j.watres.2020.116319] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 08/08/2020] [Accepted: 08/18/2020] [Indexed: 06/11/2023]
Abstract
Reservoirs are an important source of atmospheric methane (CH4), a potent greenhouse gas. The Mekong, one of the largest Asian rivers, has been heavily dammed and can be a potential hotspot for CH4 emissions. While low diffusive CH4 flux was previously reported from cascading reservoirs in the Upper Mekong, the contribution of ebullition (bubbling) remained unexplored. To better constrain the magnitude and drivers of ebullition from these reservoirs, automated bubble traps were deployed in four reservoirs, allowing for continuous measurement of the ebullitive flux with high temporal resolution for a period of six months. To characterize the spatial variability of CH4 fluxes mediated by ebullition and diffusion, whole-reservoir surveys were conducted using a scientific echo sounder for bubble observations together with a gas equilibrator for mapping dissolved CH4 concentration in surface water from which diffusive fluxes were estimated. Potential production and anaerobic oxidation rates of CH4 were estimated in laboratory incubations of sediment cores collected near the bubble trap deployment sites. The CH4 production potential in sediments increased strongly along the reservoir cascade, with mostly minor reduction by anaerobic oxidation. Surface CH4 fluxes, in contrast, showed high spatial variability in both ebullitive and diffusive pathways (ranging 0.05-44 and 1.8-6.4 mg m-2 d-1, respectively, among all reservoirs). Ebullitive fluxes were about one order of magnitude higher than diffusive fluxes and remained significant at sites as deep as 30-45 m. The repeated spatial pattern of ebullition (higher fluxes at the dam area than in upstream sections) suggests the possible control of emission rates by sediment transport and deposition.
Collapse
|
15
|
Magnetic toroidal dipole response in individual all-dielectric nanodisk clusters. NANOSCALE 2020; 12:10639-10646. [PMID: 32373891 DOI: 10.1039/d0nr01440k] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Multipole electromagnetic resonances and their couplings are of crucial importance for both the fundamental understanding of light scattering by high-index all-dielectric nanostructures and lots of nanophotonic applications based on those nanostructures. Here, we show that magnetic dipole modes in a dielectric nanodisk cluster can easily form a magnetic toroidal dipole (MTD) mode. The cluster consists of five silicon nanodisks, where each nanodisk holds a magnetic dipole mode. These magnetic dipole modes can collectively couple with each other and form a MTD mode under suitable excitation. The MTD mode is confirmed by multipole expansion calculations and near field distributions, where two closed loops of magnetic field with opposite directions are seen. The response of the MTD is strong and comparable to that of a common electric dipole or magnetic dipole mode. It is also found that the MTD resonance is accompanied by an electric toroidal quadrupole mode in the cluster. The MTD mode is tunable by varying the geometries. We also fabricated silicon nanoparticle clusters and verified the MTD mode in the experiment. Our results illustrate the controllable excitation of strong high-order electromagnetic modes and these modes may open new opportunities for light manipulation at the nanoscale.
Collapse
|
16
|
Strategic modulation of energy transfer in Au-TiO 2-Pt nanodumbbells: plasmon-enhanced hydrogen evolution reaction. NANOSCALE 2020; 12:7035-7044. [PMID: 32207505 DOI: 10.1039/d0nr00441c] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Owing to the capacity of efficiently harvesting and converting incident energy, localized surface-plasmon resonance of noble metals was introduced into a metal-semiconductor design for promoting hydrogen evolution. In this study, a plasmonic nanodumbbell structure was employed to strategically modulate the energy transfer in the water reduction reaction. A maximum H2 evolution rate of 80 μmol g-1 h-1 was obtained in the Au-TiO2 nanodumbbells, and further improvement was achieved through surface modification with Pt nanoparticles functioning as active sites, leading to ∼4.3 times enhanced photocatalytic activity. Compared with similar nanostructures reported previously, the present superior photoactivity response is ascribed to the injection process of the energetic hot electrons generated from the excitation and decay of the longitudinal surface-plasmon resonance (LSPR) and transverse surface-plasmon resonance (TSPR) in the Au nanorods, which corresponds to the electric field distribution of the finite-difference-time-domain simulation. These intriguing results, originating from the positive synergistic effect of the plasmon and co-catalyst, demonstrated the mechanism of the plasmon-assisted photochemistry and provided a promising strategy for the rational design of novel plasmonic photocatalysts.
Collapse
|
17
|
[Value of index of microcirculatory resistance for early prediction of periprocedural myocardial microcirculatory injury after percutaneous coronary intervention in patients with coronary heart disease]. ZHONGHUA XIN XUE GUAN BING ZA ZHI 2019; 47:894-900. [PMID: 31744279 DOI: 10.3760/cma.j.issn.0253-3758.2019.11.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To explore the value of index of microcirculatory resistance (IMR) for early prediction of periprocedural myocardial injury (PMI) in patients with stable angina pectoris (SAP) and acute coronary syndrome (ACS) after PCI. Methods: It was a prospective study. One hundred and sixty-four patients who had single coronary lesion were consecutively enrolled from May 2014 to December 2017 at Nanjing Hospital affiliated to Nanjing Medical University. According to clinical manifestation, patients were divided into SAP group (n=81) and ACS group (n=83). IMR was determined by thermal dilution with pressure guide wire. Basic clinical characteristics, coronary angiographic results, PCI procedural details, IMR after PCI, ΔIMR (IMR=post-PCI-IMR pre-PCI), levels of myocardial biomarkers before and after PCI were compared between the two groups. Multivariate logistic regression was used to analyze the relation of PMI with IMR and ΔIMR, and the predictive ability was evaluated by receiver operating characteristic (ROC). Results: The levels of total cholesterol and low density lipoprotein cholesterol were significantly higher in ACS group than in SAP group (P<0.05), other clinical data at baseline were similar between the two groups (P>0.05). Quantitative coronary angiography (QCA) results and PCI related data were also similar between the two groups before PCI (P>0.05). Values of mean transit time (Tmn) of intracoronary injection with room temperature saline, post-PCI IMR and ΔIMR were significantly higher in ACS group than in SAP group after PCI (P<0.05). Plasma creatine kinase isoenzyme-MB difference (ΔCK-MB) (ΔCK-MB=CK-MB post-PCI-CK-MB pre-PCI) and cardiac troponin-I (cTnI) difference (ΔcTnI=cTnI post-PCI-cTnI pre-PCI) were significantly larger in ACS group than in SAP group (P<0.05). Multivariate logistic regression analysis showed that coronary artery disease (CHD) type (SAP and ACS) (OR=1.301, 95%CI 1.083-1.562), age (OR=1.007, 95%CI 1.000-1.013), ΔIMR (OR=1.009, 95%CI 1.000-1.017) and post-PCI IMR (OR=1.008, 95%CI 1.001-1.014) were independent predictors of PMI (P<0.05). The area under the ROC curve (AUC) of ΔIMR was 0.763 to predict PMI (P<0.05), the optimum cut-off value of ΔIMR was 5.485 with 70.0% sensitivity and 77.4% specificity. ΔIMR was positively correlated with ΔcTnI (r=0.592, P<0.05). Conclusions: ΔIMR serves as an early predictor of PMI in CHD patients after PCI. As compared with SAP patients, ACS patients are more likely to develop PMI.
Collapse
|
18
|
[Summary of the 2019 Academic Annual Meeting of the Society of Burn Surgery of Chinese Medical Doctor Association]. ZHONGHUA SHAO SHANG ZA ZHI = ZHONGHUA SHAOSHANG ZAZHI = CHINESE JOURNAL OF BURNS 2019; 35:559-560. [PMID: 31357832 DOI: 10.3760/cma.j.issn.1009-2587.2019.07.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The 2019 Academic Annual Meeting of the Society of Burn Surgery of Chinese Medical Doctor Association, sponsored by the Chinese Medical Doctor Association, was successfully held in Jinan, Shandong Province from May 22th to 24th. More than 300 representatives of burn department attended the meeting. With the theme of " Standardization and Innovation" , the conference focused on academician lectures and invited reports, thematic reports, thematic discussions, and discussion of difficult and complex cases in view of the current situation and challenges of burn specialty in China, and closely combined with the actual clinical needs. In order to reserve the reserve force, the Youth Committee of the Society of Burn Surgery of Chinese Medical Doctor Association was established.
Collapse
|
19
|
Abstract
Lung cancer is the most common type of cancer and the leading cause of death in worldwide. MicroRNAs are known to be key players in a variety of biological processes, including tumorigenesis. In present study, we investigated the effect of miR-361-5p on lung cancer progression. We found that miR-361-5p was down-regulated in lung cancer. Overexpression of miR-361-5p suppressed lung cancer proliferation and invasion. Mechanistically, FOXM1 was identified as a direct target of miR-361-5p. Furthermore, miR-361-5p inhibits EMT-like phenotype through down-regulation of FOXM1 expression in lung cancer cells. In conclusion, our results indicated that miR-361-5p acts as a tumor suppressor in lung cancer.
Collapse
|
20
|
Effects of Si solute on the glass formation and atomic structure of Pd liquid. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2019; 31:135701. [PMID: 30625432 DOI: 10.1088/1361-648x/aafd02] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Molecular dynamics simulations were performed to study the effects of Si solute on the glass formation and crystallization of Pd liquid. Pure Pd samples prepared by a quenching process with a cooling rate of 1013 K s-1 can be in an amorphous state but the structural analysis indicates there is nearly no glass-forming motif in the sample. However, doping a small amount of Si (Si concentration ~4%) the sample can be vitrified at a cooling rate of 1012 K s-1. The glass-forming motifs such as Pd-centered Z13, Si-centered Z9-like and mixed-ICO-cube clusters with five-fold local symmetry are found to be the dominant short-range orders in the glassy samples. With the increasing of the Si-doping concentration, these glass-forming motifs tend to aggregate and connect with each other forming a network structure. Our calculated results revealed that Si solutes in liquid Pd can significantly enhance the glass-forming ability.
Collapse
|
21
|
Magnetic Plasmon-Enhanced Second-Harmonic Generation on Colloidal Gold Nanocups. NANO LETTERS 2019; 19:2005-2011. [PMID: 30721073 DOI: 10.1021/acs.nanolett.9b00020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The magnetic plasmons of three-dimensional nanostructures have unique optical responses and special significance for optical nanoresonators and nanoantennas. In this study, we have successfully synthesized colloidal Au and AuAg nanocups with a well-controlled asymmetric geometry, tunable opening sizes, and normalized depths ( h/ b, where h is depth and b is the height of the templating PbS nanooctahedrons), variable magnetic plasmon resonance, and largely enhanced second-harmonic generation (SHG). The most-efficient SHG of the bare Au nanocups is experimentally observed when the normalized depth h/ b is adjusted to ∼0.78-0.79. We find that the average magnetic field enhancement is maximized at h/ b = ∼0.65 and reveal that the maximal SHG can be attributed to the joint action of the optimized magnetic plasmon resonance and the "lightning-rod effect" of the Au nanocups. Furthermore, we demonstrate for the first time that the AuAg heteronanocups prepared by overgrowth of Ag on the Au nanocups can synergize the magnetic and electric plasmon resonances for nonlinear enhancement. By the tailoring of the dual resonances at the fundamental excitation and second-harmonic wavelengths, the far-field SHG intensity of the AuAg nanocups is enhanced 21.8-fold compared to that of the bare Au nanocups. These findings provide a strategy for the design of nonlinear optical nanoantennas based on magnetic plasmon resonances and can lead to diverse applications ranging from nanophotonics to biological spectroscopy.
Collapse
|
22
|
[Analysis of prognostic factors on multidisciplinary team for diagnosis, treatment and prevention of hepatocellular carcinoma]. ZHONGHUA GAN ZANG BING ZA ZHI = ZHONGHUA GANZANGBING ZAZHI = CHINESE JOURNAL OF HEPATOLOGY 2019; 26:829-834. [PMID: 30616317 DOI: 10.3760/cma.j.issn.1007-3418.2018.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To analyze the prognostic factors on multidisciplinary team patients for diagnosis, and treatment of hepatocellular carcinoma. Methods: This retrospective study enrolled 132 HBsAg positive patients with HCC. MDT diagnostic approach was conducted at our hospital between 1 January 2015 and 31 December 2015, and all patients were followed up to 31 December 2017. Groups were arranged according to variables such as Barcelona stage, MDT compliance, and multidisciplinary combination therapy. TTP and OS were statistically analyzed. Results: The survival of the MDT compliance group was better than the non-compliance group. The difference in survival curves was statistically significant (χ(2) = 4.062, P < 0.05). The 1- and 2-year survival rates of the former group were 72.0%, 60.9%, and the latter was 64.3%, 40.3%. The survival of the combined treatment group was better than the non-combination group. The survival curves of the two groups were statistically significant (χ(2) = 9.502, P < 0.05), and they were independent influencing factors of survival (HR = 0.451, 95% CI, 0.210-0.968). The 1- and 2-year survival rates of the former group were 82.2% and 75.4%, and the latter was 63.1% and 44.6%. The median survival time of the follow-up group was 29.4 months, and the non-compliance and the uncombined group were 17.0 months. The difference was statistically significant (χ(2) = 13.336, P < 0.001). The median tumor progression time was 15.7 months in the combination group and 10.1 months in the non-compliance group (χ(2) = 7.263, P < 0.05). Conclusion: An advanced MDT compliance with implementation of multidisciplinary combination therapy may help to improve the prognosis of MDT patients with liver cancer.
Collapse
|
23
|
[Application of restricted mean survival time in clinical follow-up study]. ZHONGHUA LIU XING BING XUE ZA ZHI = ZHONGHUA LIUXINGBINGXUE ZAZHI 2019; 40:247-250. [PMID: 30744281 DOI: 10.3760/cma.j.issn.0254-6450.2019.02.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In clinical follow-up studies, hazard ratio (HR) is routinely used to quantify the differences between-groups, however, it is being estimated by the Cox procedure. HR, the ratio of two hazard functions has abstract meaning only and is in lack of the context to give an intuitive explanation of the survival of patients and the assumption of proportional hazards (PH) must be satisfied. Under this context, the restricted mean survival time (RMST) can be used as a relatively effective measure or index of statistics. This paper introduces the RMST-based statistical analysis methods, including estimation of RMST and its difference, hypothesis testing and regression analysis. The application of RMST in data analysis is also introduced. All the evidence demonstrates that RMST can be used as an effective analytical tool with straightforward interpretation. RMST is also more effective than HR in comparing differences between groups, when non-PH is observed. Therefore, RMST is suggested to be stated along with HR in the process of disease efficacy evaluation and prognosis analysis. Cooperation and complement of the two, a precise reflection on the characteristics of data can be expected.
Collapse
|
24
|
Plasmonic nanoantenna-dielectric nanocavity hybrids for ultrahigh local electric field enhancement. OPTICS EXPRESS 2018; 26:31116-31128. [PMID: 30650702 DOI: 10.1364/oe.26.031116] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Accepted: 10/22/2018] [Indexed: 06/09/2023]
Abstract
A dielectric nanostructure with a high refractive index can exhibit strong optical resonances with considerable electric field enhancement around the entire structure volume. Here we show theoretically that a dielectric structure with this feature can boost the local electric field of a small plasmonic nanoantenna placed nearby. We construct a hybrid system of a plasmonic nanoantenna and a dielectric nanocavity, where the nanocavity is a concentric disk-ring structure with a lossless material n = 3.3 and the nanoantenna is a gold nanorod dimer. The resonant electric field enhancement at the gap center of the antenna in the hybrid structure reaches more than one order of magnitude higher than that of the individual antenna. The dielectric structure plays two roles in the hybrid system, namely the amplified excitation field and an environment causing the redshift of the antenna resonance. The hybrid configuration is applicable to the cases with various geometries and different materials of the hybrid system. Our results can find applications in enhanced nanoscale light-matter interactions such as surface-enhanced Raman scattering, nonlinear optics, and plasmon-exciton couplings.
Collapse
|
25
|
[The effect of pre-operation (125)I seed activity measuring on dose accuracy]. ZHONGHUA YI XUE ZA ZHI 2018; 98:3336-3338. [PMID: 30440124 DOI: 10.3760/cma.j.issn.0376-2491.2018.41.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Objective: To measure the activity of (125)I seed and compare the dose difference of ten patients treated with seed implantation in pre-plan with actual seed activity and calibrate activity. Method: The activity of 100 seeds from company A and B was measured with a well-type ionization chamber 1 day before operation and named group A and B. The activity of two groups was compared and the error between actual and calibrate activity (22.2 MBq, group C) was calculated. Ten patients implanted with (125)I seeds from November 1 st to 30 th, 2017, solstice 30 were selected in Hebei General Hospital. Firstly, pre-plans were designed with 22.2 MBq, prescribed dose were 100-140 Gy. The dose parameters of 90% volume absorbed dose (D(90)), 150% volume fraction (V(150)) and 100% volume fraction (V(100)) were calculated. Then changed 22.2 MBq to actual activity of group A and B, calculated the dose parameters above again. Then dose parameters of D(90), V(150), V(100) in group C were compared with those in group A and B respectively. Result: The actual activity 1 day before the operation was(22.6±0.7)and(23.9±0.9)MBq in group A and B respectively. Compared with 22.2 MBq, the difference was statistically significant(t=5.7, P<0.05 and t=19.2, P<0.05), and the activity error of group B was greater than 5%. The D(90) of group A, B and C were (124.3±9.7) , (131.2±10.2) and (121.9±9.5) Gy respectively.The V(150) were 58.4%±9.4%, 63.7%±8.9% and 56.5%±9.2% respectively. The V(100) were 88.9%±5.0%, 92.0%±4.1%, 88.1%±5.2% respectively.The difference of D(90) between calibrate activity(group C) and actual activity(group A and B) were statistically significant (t=40.2, P<0.05 and t=40.3, P<0.05). The difference of V(150) between group C and group A and B were statistically significant (t=7.5, P<0.05 and t=24.7, P<0.05). The difference of V(100) between group C and group A and B were statistically significant (t=6.6, P<0.05 and t=7.3, P<0.05). Conclusion: There is difference between the actual activity and calibration activity. The difference affects the dose parameters in pre-plan.The seed activity should be measured before operation strictly and the pre-plan should be designed with the actual activity.
Collapse
|
26
|
Measurement of the toroidal radiation asymmetry during massive gas injection triggered disruptions on J-TEXT. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10E113. [PMID: 30399685 DOI: 10.1063/1.5035187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 06/21/2018] [Indexed: 06/08/2023]
Abstract
Disruptions have the potential to cause severe damage to large tokamaks like ITER. The mitigation of disruption damage is one of the essential issues for the tokamak. Massive gas injection (MGI) is a technique in which large amounts of a noble gas are injected into the plasma in order to safely radiate the plasma energy evenly over the entire plasma-facing wall. However, the radiated energy during the disruption triggered by massive gas injection is found to be toroidally asymmetric. In order to investigate the spatial and temporal structures of the radiation asymmetry, the radiated power diagnostics for the J-TEXT tokamak have been upgraded. The multi-channel arrays of absolute extreme ultraviolet photodiodes have been upgraded at four different toroidal positions to investigate the radiation asymmetries during massive gas injection. It is found that the toroidal asymmetry is associated with plasma properties and MGI induced MHD activities.
Collapse
|
27
|
Hyperbolic lens design of local oscillator optics system for electron cyclotron emission imaging on J-TEXT. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10H101. [PMID: 30399902 DOI: 10.1063/1.5035098] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
An electron cyclotron emission imaging diagnostic system that contains two 16-antenna arrays is being developed on J-TEXT tokamak. In this heterodyne system, the mixers in the front microwave antenna are used to down-convert the electron cyclotron emission to a 2-12 GHz radio frequency. All of the 24 antenna mixers in the individual enclosure box are driven by shining local oscillator (LO) power via launching optics. The previous approach for LO optics was designed with spherical and cylinder lenses, which has limitations such as the inhomogeneity of the energy deposition on different channels and the difficulty of optics alignment. A new generation of LO optics has been designed and applied on J-TEXT with a hyperbolic lens for uniform power deposition across the entire antenna array. The robustness of the optical alignment will be significantly increased with three hyperbolic lenses. Furthermore, the simulation results and robustness analysis of these LO optics are discussed in this paper.
Collapse
|
28
|
Design of a shattered pellet injection system on J-TEXT tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10K116. [PMID: 30399929 DOI: 10.1063/1.5035186] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 08/08/2018] [Indexed: 06/08/2023]
Abstract
Disruptions have the possibility of causing severe wall damage to large tokamaks like ITER. The mitigation of disruption damage is essential to the safe operation of a large-scale tokamak. The shattered pellet injection (SPI) technique, which is regarded as the primary injection method for ITER, presents several advantages relative to massive gas injection, including more rapid particle delivery, higher total particle assimilation, and more centrally peaked particle deposition. A dedicated argon SPI system that focuses on disruption mitigation and runaway current dissipation has been designed for the Joint Texas Experimental Tokamak (J-TEXT). A refrigerator is used to form a single argon pellet at around 64 K. The pellet will be shaped with a 5 mm diameter and a 1.5-10 mm length. Helium gas at room temperature will be used as a propellant gas for pellet acceleration. The pellet can be injected with a speed of 150-300 m/s. The time interval between injection cycles is about 8 min. The pellet will be shattered at the edge of the plasma and then injected into the core of plasma. The first experiments of SPI fast shutdown and runaway current dissipation have been performed.
Collapse
|
29
|
Vertical fast electron bremsstrahlung diagnostic on J-TEXT tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10F126. [PMID: 30399909 DOI: 10.1063/1.5035185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 07/14/2018] [Indexed: 06/08/2023]
Abstract
Fast electron bremsstrahlung (FEB) emission during Ohmic discharge experiments on the Joint Texas Experimental Tokamak (J-TEXT) has been measured by a recently developed vertical multi-channel FEB diagnostic based on CdZnTe detectors. There are 5 sight lines to observe the vertical emission of fast electrons at the high-field side with a spatial resolution of 5 cm. The FEB emission in the energy range of 30-300 keV can be measured. The generation of fast electrons accelerated by loop voltage has been confirmed during the early phase of discharge by analyzing the signals of FEB emission. The runaway electron beam instabilities have been observed with the FEB diagnostic on J-TEXT.
Collapse
|
30
|
Measurement of electron temperature fluctuations on J-TEXT via correlation ECE. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10H105. [PMID: 30399888 DOI: 10.1063/1.5035121] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 05/28/2018] [Indexed: 06/08/2023]
Abstract
The capabilities of the joint-Texas experimental tokamak correlation electron cyclotron emission (CECE) diagnostic have recently been extended with an upgrade. Four new yttrium iron garnet (YIG) filters from 4 GHz to 18 GHz with a bandwidth of 90 ∼ 230 MHz are added to the previous 4 channels. Optical optimization of the transmission line has improved the poloidal resolution, which allows k θ < 3.08 cm-1. The improvement of video amplifiers allows the frequency and amplitude gain to be adjusted discretely from 200 kHz to 1 MHz and from 200 to 1000, respectively, for different situations. A controller is designed to remotely adjust the center frequency of the YIG filters. Based on the CECE, the distribution and the effect of magnetohydrodynamic instabilities on electron temperature fluctuations have been observed. The experiment results show good performance of the upgraded CECE diagnostic.
Collapse
|
31
|
Abnormal nonlinear optical properties of hybrid graphene-TiO 2 nanostructures. OPTICS LETTERS 2018; 43:523-526. [PMID: 29400831 DOI: 10.1364/ol.43.000523] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Accepted: 12/27/2017] [Indexed: 06/07/2023]
Abstract
The nonlinear optical (NLO) properties of graphene-TiO2 nanoparticle (GNP) composite and graphene-TiO2 nanowire composite (GNW) are investigated by spatial self-phase modulation (SSPM) and Z-scan. The SSPM results of the GNP and GNW show that they possess strong self-diffraction effects at 1100 nm and no signal at 700 nm, which is different from all previous reports of other two-dimensional materials. A possible mechanism is that NLO behaviors are dominated by TiO2 at the visible wavelength, while by graphene at a near-infrared wavelength. The Z-scan results of the GNP and GNW show reverse saturable absorption (RSA) at 700 nm, but saturable absorption (SA) at 1100 nm. Our results demonstrate that, by choosing appropriate coupling, we could design two-dimensional materials that have specific NLO properties at particular wavelengths.
Collapse
|
32
|
[Beneficial effects of Schisandrin B on the cardiac structure and function in a mice model of myocardial infarction]. ZHONGHUA XIN XUE GUAN BING ZA ZHI 2017; 45:963-970. [PMID: 29166724 DOI: 10.3760/cma.j.issn.0253-3758.2017.11.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigate whether Schisandrin B (Sch B) could improve cardiac structure and function in myocardial infarction (MI) mice and related mechanisms. Methods: Male C57BL/6J mice were randomized into sham (n=8), MI+ Sch B (n=24, 80 mg·kg(-1)·d(-1) per gavage) or MI+ vehicle (n=24, equal volume). After treatment for 3 weeks, cardiac function was detected by echocardiography measurement.Infarction size was measured by Evans blue and TTC staining.HE and Masson trichrome staining were used to observe the myocardial inflammation, structure and fibrosis.TNF-α, TGF-β, IL-1β were detected by ELISA. The apoptosis index of ischemic myocardial cells was detected by immunofluorescence. NF-κB, Bcl-2, Bax, Akt phosphorylated Akt(p-Akt), eNOS, phosphorylated eNOS (p-eNOS) were detected by Western blot. Results: Three weeks after operation, survival rate (83.33% vs. 54.17%, P<0.05), LVEF((51.77±8.50)% vs.(40.23±8.30)%, P<0.05), LVFS((26.44±5.15)% vs. (19.53±4.56)%, P<0.05)were significantly higher; LVEDD ((4.13±0.40) mm vs.(4.44±0.46)mm, P<0.05), LVESD((3.07±0.39) mm vs. (3.46±0.52)mm, P<0.05), the heart weight/body weight ratio((0.59±0.06)% vs. (0.68±0.10)%, P<0.05)was significantly lower and infarct size ((23.4±2.36)% vs. (39.4±2.06)%, P<0.05) was significantly reduced in MI+ Sch B group than those in MI+ vehicle group. In MI+ vehicle group, HE staining showed a large number of inflammatory cells in the peri-infarctl region, and the permutation structure was very disorganized, while above changes were significantly reduced in the MI+ Sch B group. Masson staining results showed that the degree of myocardial fibrosis in MI+ Sch B group was significantly less than that of MI+ vehicle group.Moreover, Sch B could down-regulate some inflammatory cytokines, like NF-κB、TGF-β、TNF-α and IL-1β, activate Akt-eNOS pathway, upgrade Bcl-2 and downgrade Bax and reduce cell apoptosis as compared with MI+ vehicle group (all P<0.05). Conclusions: Our results demonstrate that Sch B can reduce inflammation, inhibit apoptosis, and attenuate cardiac remodeling and improve cardiac function in this mice MI model.Sch B might serve as a potential novel therapeutic agent for ischemic heart disease.
Collapse
|
33
|
[Comparison of the short-term and long-term outcomes of laparoscopic surgery and open surgery for early-stage cervical cancer]. ZHONGHUA ZHONG LIU ZA ZHI [CHINESE JOURNAL OF ONCOLOGY] 2017. [PMID: 28635237 DOI: 10.3760/cma.j.issn.0253-3766.2017.06.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To evaluate the short-term and long-term outcomes after laparoscopic surgery compared with traditional laparotomy in cases of stage ⅠA2-ⅡA2 cervical cancer. Methods: We conducted a retrospective study on the clinical data of 1 863 patients diagnosed as FIGO stages ⅠA2-ⅡA2 cervical cancer in 6 third-grade class-A hospitals in Guangxi province between January 2007 and May 2014. One thousand and seventy-one received laparoscopy, and 792 received laparotomy. T-test, U-test and χ(2) test were used to compare the short-term and long-term outcomes. The short-term outcomes included surgical related outcomes and operative complications, and the long-term outcomes included quality of life (pelvic floor functions and sexual functions), survival and recurrence. Pelvic floor function and sexual function were assessed with the International Consultation on Incontinence Quesonnaire Female Lower Urinary tract(ICIQ-FLUTS) and the Female Sexual Function Inventory (FSFI), respectively. Survival rates were estimated by Kaplan-Meier analysis. The survival curves were compared with Log-rank test. Cox regression analysis was used to evaluaterisk factors for prognosis. Results: (1)The short-term outcomes : There were significant difference in operative time([(257±69) vs(238±56)min], estimated blood loss[(358±314) vs(707±431)ml], anus exhausting time[(2.5±0.9) vs (2.9±0.8)d], preserved days of catheter[(15±7) vs(18±9)d], and post-operative length of stay[(19±16) vs (30±21)d] between the laparoscopic surgery group and the opensurgery group(P<0.05). There was no significant difference in lymph nodes yielded[(21±9) vs (21±11)], left parametrial width[(2.5±0.8) vs (2.7±0.7)cm], right parametrial width [(2.6±0.3) vs (2.7±0.2)cm], vaginal cuff length[(2.4±0.7) vs (2.2±0.7)cm] between the laparoscopic surgery group and the opensurgery group(P>0.05). The intra-operative complications occurred in 8.1%(87/1 071)in the laparoscopic surgery group and in 10.7%(85/792)in the open surgery group(P>0.05). However, the complications of vascular injury in the laparoscopic surgery group[2.6%(28/1 071)]was lower than that in the open surgery group[7.7%(61/792), P<0.001]. The laparoscopic surgery exhibited lower post- operative complication rate [33.8%(362/1 071)vs 40.2%(318/792), P<0.05] and poorer wound healing rate [0.7%(7/1 071)vs 4.0%(32/792), P<0.05]. (2)The long-term outcomes(Hierarchical analysis): The overall incontinence in ICIQ-FLUTS questionnaire in nerve-sparing laparoscopic group [28.4%(67/236)] was lower than that in the open surgery group [35.9%(71/198), P=0.004] . However, There was no significant difference in degree of incontinence between the two groups(P>0.05). The overall sexual dysfunction in FSFI questionnaire after 12 months of postoperative in the nerve-sparing laparoscopic group [47.0%(111/236)]was lower than that in the open surgery group [58.6%(116/198), P=0.001], and the six different dimension scores in the laparoscopic surgery group were higher than that in the open surgery group (P<0.05). The recurrence rate was 3.5%(35/1 007)in the laparoscopicsurgery group and 4.7%(35/740)in the open surgery group(P>0.05). The 5-year OS was 94.0% for the laparoscopic surgery group and 90.2% for the open surgery group(P>0.05), and the 5-year DFS was 93.9% for the laparoscopic surgery group and 89.1% for the open surgery group(P>0.05). (3) Prognostic fators: In univariate analysis, tumor dimension, clinical stage, deep stromal invasion, LVSI, and retroperitoneal lymph node metastasis signficantly affected 5-year OS and 5-year DFS(P<0.05); In multivariate analyses, LVSI, deep stromal invasion and LN metastasis were independent prognostic factors(P<0.05). Conclusions: Laparoscopy can reduceestimated blood loss, accelerate postoperative recovery and improve the quality of life after surgery compared to laparotomy, and it ensures the same oncological results as open surgery. Laparoscopic approach is a safe and effective treatment for early-stage cervical cancer.
Collapse
|
34
|
Boosting magnetic field enhancement with radiative couplings of magnetic modes in dielectric nanostructures. OPTICS EXPRESS 2017; 25:15927-15937. [PMID: 28789103 DOI: 10.1364/oe.25.015927] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 06/23/2017] [Indexed: 06/07/2023]
Abstract
Dielectric nanostructures can readily support considerable magnetic field enhancements that offer great potential applications in field enhanced spectroscopies. However, the magnetic fields of dielectric structures are usually distributed within the entire volume, which brings challenge to the further increment of the magnetic field enhancement. Here, we theoretically demonstrate that the magnetic field enhancement in dielectric nanostructures can be boosted through the radiative couplings of magnetic modes. Our concentric structure consists of a hollow disk and a ring. The disk has a magnetic dipole mode. The ring has two magnetic dipole modes that are out of phase. Strong radiative interactions between the modes on the disk and the ring can occur, which result in a net constructive coupling effect. For a lossless material with n = 3.3, a sharp peak can be obtained on the scattering spectrum of the coupled system due to the radiative interactions. The corresponding resonant magnetic field enhancement at the disk center reaches 96 times. This enhancement is about 7 times higher than that of an individual disk. The structure with a lossy material Si is also considered, where radiative couplings and boosted magnetic field can also be obtained. Our research reveals the strong radiative mode couplings in dielectric structures and is important for furthering our understanding on the light-matter interactions at the nanoscale.
Collapse
|
35
|
[Clinical validation of multiple biomarkers suspension array technology for ovarian cancer]. ZHONGHUA FU CHAN KE ZA ZHI 2017; 52:11-19. [PMID: 28190310 DOI: 10.3760/cma.j.issn.0529-567x.2017.01.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigates the diagnostic value of combined detection serum CCL18, CXCL1 antigen, C1D, TM4SF1, FXR1, TIZ IgG autoantibody by suspension array for ovarian cancer. Methods: Suspension array was used to detect CCL18, CXCL1 antigen, C1D, TM4SF1, FXR1, TIZ IgG autoantibody in 120 cases of healthy women, 204 cases of patients with benign pelvic tumors, 119 cases of pelvic malignant tumor patients, and 40 cases with breast cancer, lung cancer oroliver cancer, respectively. Constructed diagnosis model of combined detection six biomarkers for diagnosis of ovarian malignant tumor. Constructed diagnosis model of combined detection autoantibodies to diagnose epithelial ovarian cancer. Analysed the value of detecting six biomarkers for diagnosis of ovarian malignant tumor and detecting autoantibodies for diagnosis of epithelial ovarian cancer. Analysed diagnostic value of detecting six biomarkers to diagnose stage Ⅰ and Ⅱepithelial ovarian cancer. Compared diagnostic value of detecting six biomarkers in diagnosis of tissue types and pathologic grading with that of CA(125). Results: Model of combined detecting six biomarkers to diagnose ovarian malignant tumor was logit (P) =-11.151+0.008×C1D+0.011×TM4SF1+0.011×TIZ-0.008×FXR1+0.021×CCL18+0.200×CXCL1. Model of combined detection autoantibodies to diagnose epithelial ovarian cancer was logit (P) =-5.137+0.013×C1D+0.014×TM4SF1+0.060×TIZ-0.060×FXR1. Sensitivity and specificity of detecting six biomarker to diagnose ovarian malignant tumor was 90.6% and 98.7%. Sensitivity and specificity of detecting autoantibodies to diagnose epithelial ovarian cancer was 75.8% and 96.7%. Combined detection for six biomarkers to diagnose serous and mucinous ovarian cancer was statistically no better than those of CA(125) (P=0.196 and P=0.602, respectively); there was significantly difference in diagnosis of ovarian cancer (P=0.023), and there was no significantly difference in diagnosis of different pathological grading (P=0.089 and P=0.169, respectively). Conclusions: Constructing diagnosis model of combined detection six biomarker to diagnose ovarian malignant tumor and constructed diagnosis model of combined detectionautoantibodies to diagnose epithelial ovarian cancer. Combined detection six biomarkers to diagnose serous and mucinous ovarian tumors is better than that of CA(125).
Collapse
|
36
|
Magnetic Fano resonance-induced second-harmonic generation enhancement in plasmonic metamolecule rings. NANOSCALE 2017; 9:6068-6075. [PMID: 28443939 DOI: 10.1039/c7nr00587c] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The "artificial magnetic" resonance in plasmonic metamolecules extends the potential application of magnetic resonance from terahertz to optical frequency bypassing the problem of magnetic response saturation by replacing the conduction current with the ring displacement current. So far, the magnetic Fano resonance-induced nonlinearity enhancement in plasmonic metamolecule rings has not been reported. Here, we use the magnetic Fano resonance to enhance second-harmonic generation (SHG) in plasmonic metamolecule rings. In the spectra of the plasmonic metamolecule, an obvious Fano dip appears in the scattering cross section, while the dip does not appear in the absorption cross section. It indicates that at the Fano dip the radiative losses are suppressed, while the optical absorption efficiency is at a high level. The largely enhanced SHG signal is observed as the excitation wavelength is adjusted at the magnetic Fano dip of the plasmonic metamolecule rings with stable and tunable magnetic responses. We also compare the magnetic Fano dip with the electric case to show its advantages in enhancing the fundamental and second harmonic responses. Our research provides a new thought for enhancing optical nonlinear processes by magnetic modes.
Collapse
|
37
|
[The management for pediatric chronic rhinosinusitis with upper respiratory tract concomitant diseases]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY, HEAD, AND NECK SURGERY 2017; 31:446-450. [PMID: 29871283 DOI: 10.13201/j.issn.1001-1781.2017.06.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Indexed: 06/08/2023]
Abstract
Objective:To analyze the clinical impact of upper respiratory tract concomitant diseases in pediatrics chronic rhinosinusitis(CRS) and treatment methods, efficacy and timing of the concomitant diseases.Method:Two hundred and sixty-seven cases with CRS at a tertiary children's medical center from March 2013 to March 2015 were included in this study. The cases were divided into two groups according to the concomitant diseases. 66 cases without concomitant diseases were allocated into group A;201 cases with concomitant diseases were classified into group B. Group B was further divided into two subgroups according to treatment methods: subgroup B1(97 cases) and subgroup B2(104 cases). Group A and B1 were given the same basic treatment for 3 months,while Group B2 was given the basic plus targeted treatment for the same duration. Comprehensive evaluation was conducted at 3, 6 and 15-months after commencement of treatment. Result:The therapeutic effect of Group A was significantly superior to Group B1 in 3 months(P<0.05).The clinical efficacy of Group A decreased slightly while Group B1 showed significantly reduced efficacy at 6 and 15-months (all P<0.05). Comparing Group B1 and B2, the comprehensive effect of Group B2 was considerably better than Group B1 at 3 months(P<0.05). Furthermore, Group B2 showed no decrease in efficacy while Group B1 decreased significantly at 6 and 15-month. Conclusion:Recurrent upper respiratory tract infections, allergic rhinitis, adenoid hypertrophy and chronic tonsillitis, were common the upper respiratory tract accompanying diseases in children with CRS, and they had significant influence on the efficacy and recurrence of CRS. The basic plus targeted treatment can improve the efficacy and reduce recurrence.
Collapse
|
38
|
[Current status and future of epithelial ovarian cancer markers]. ZHONGHUA FU CHAN KE ZA ZHI 2017; 52:4-7. [PMID: 28190308 DOI: 10.3760/cma.j.issn.0529-567x.2017.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
|
39
|
Quasi mode-locking of coherent feedback random fiber laser. Sci Rep 2016; 6:39703. [PMID: 28004785 PMCID: PMC5177947 DOI: 10.1038/srep39703] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Accepted: 11/25/2016] [Indexed: 01/22/2023] Open
Abstract
Mode-locking is a milestone in the history of lasers that allows the generation of short light pulses and stabilization of lasers. This phenomenon is known to occur only in standard ordered lasers for long time and until recently it is found that it also occurs in disordered random lasers formed by nanoscale particles. Here, we report the realization of a so-called quasi mode-locking of coherent feedback random fiber laser which consists of a partially disordered linear cavity formed between a point reflector and a random distributed fiber Bragg grating array with an inserted graphene saturable absorber. We show that multi-groups of regular light pulses/sub-pulses with different repetition frequencies are generated within the quasi mode-locking regime through the so-called collective resonances phenomenon in such a random fiber laser. This work may provide a platform to study mode locking as well as pulse dynamic regulation of random lasing emission of coherent feedback disordered structures and pave the way to the development of novel multi-frequency pulse fiber lasers with potentially wide frequency tuning range.
Collapse
|
40
|
Interleukin-8 -251A/T polymorphism and periodontitis susceptibility: a meta-analysis. GENETICS AND MOLECULAR RESEARCH 2016; 15:gmr-15-04-gmr.15047379. [PMID: 27886329 DOI: 10.4238/gmr15047379] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The -251A/T polymorphism in the anti-inflammatory cytokine interleukin-8 (IL-8) gene has been implicated in susceptibility to periodontitis; however, this correlation has not been elucidated. In this meta-analysis, we investigated the association between the IL-8 -251A/T polymorphism and the risk of periodontitis. All eligible case-control studies published until August 2014 were identified and extracted from PubMed, Web of Science, EMBASE, China National Knowledge Internet, and WanFang databases. The strength of this association was accessed by pooled odds ratios (ORs) with 95% confidence intervals (CIs), using either a fixed- or random-effect model. Nine case-control studies, including 1811 cases and 2043 controls, were identified. Overall, no significant associations were found between the IL-8 -251A/T polymorphism and the risk of periodontitis. The results of the analysis of periodontitis subgroup revealed similarities between chronic periodontitis and aggressive periodontitis. An additional analysis based on ethnicity revealed an association between the IL-8 -251A/T polymorphism and periodontitis among Asians (dominant model, OR = 1.784, 95%CI = 1.130-2.817) and a mixed population (AA vs TT, OR = 0.667, 95%CI = 0.471-0.974). The results of this meta-analysis suggest that the IL-8 -251A/T polymorphism may increase the risk of periodontitis in Asian and mixed populations. However, larger and well-designed studies are warranted to validate our findings.
Collapse
|
41
|
Electron cyclotron emission radiometer upgrade on the J-TEXT tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11E112. [PMID: 27910414 DOI: 10.1063/1.4960167] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
To meet experimental requirements, the J-TEXT electron cyclotron emission (ECE) diagnostic is being upgraded. The front end antenna and transmission line have been modified and a new 8-channel W-band detecting unit has been developed. The improved ECE system will extend the frequency range from 94.5-124.5 GHz to 80.5-124.5 GHz. This will enable the system to cover the most plasma in the radius direction for BT = 1.8-2.2 T, and it even can cover almost the whole plasma range ρ = - 0.8-0.9 (minus means the high field side) at BT = 1.8 T. A new auxiliary channel bank with 8 narrow band, tunable yttrium iron garnet filters is planned to add to the ECE system. Due to observations along a major radius, perpendicular to BT, and relatively low electron temperature, Doppler and relativistic broadening are minimal and thus high spatial resolution measurements can be made at variable locations with these tunable channels.
Collapse
|
42
|
Measurement of the internal magnetic fluctuation by the transport of runaways on J-TEXT. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11E304. [PMID: 27910575 DOI: 10.1063/1.4959876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The measurement of internal magnetic fluctuation is important for the study of transport in tokamak plasmas. The runaway electron transport induced by the sawtooth crash can be used to obtain the internal magnetic fluctuation. Inversed sawtooth-like activities on hard x-ray (HXR) fluxes following sawtooth activities were observed after the application of electrode biasing on J-TEXT tokamak. The runaway diffusion coefficient Dr is deduced to be about 30 m2/s according to the time delay of HXR flux peaks to the sawtooth crashes. The averaged value of normalized magnetic fluctuation in the discharges with electrode biasing was increased to the order of 1 × 10-4.
Collapse
|
43
|
Temperature gradient scale length measurement: A high accuracy application of electron cyclotron emission without calibration. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11E101. [PMID: 27910677 DOI: 10.1063/1.4955297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Calibration is a crucial procedure in electron temperature (Te) inference from a typical electron cyclotron emission (ECE) diagnostic on tokamaks. Although the calibration provides an important multiplying factor for an individual ECE channel, the parameter ΔTe/Te is independent of any calibration. Since an ECE channel measures the cyclotron emission for a particular flux surface, a non-perturbing change in toroidal magnetic field changes the view of that channel. Hence the calibration-free parameter is a measure of Te gradient. BT-jog technique is presented here which employs the parameter and the raw ECE signals for direct measurement of electron temperature gradient scale length.
Collapse
|
44
|
Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11E106. [PMID: 27910430 DOI: 10.1063/1.4959875] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advanced optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.
Collapse
|
45
|
[Establishment and verification of detecting multiple biomarkers for ovarian cancer by suspension array technology]. ZHONGHUA FU CHAN KE ZA ZHI 2016; 51:765-772. [PMID: 27788745 DOI: 10.3760/cma.j.issn.0529-567x.2016.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: Establish and validation of combined detecting of CCL18, CXCL1, C1D, TM4SF1, FXR1, TIZ suspension array technology. Methods: (1)CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ protein were coupled with polyethylene microspheres. Biotinylated CCL18, CXCL1 polyclonal antibody and sheep anti-human IgG polyclonal antibody were prepared simultaneously. The best packaged concentrations of CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ antigens were optimized. The best packaged concentrations of CCL18, CXCL1 polyclonal antibodys and C1D, TM4SF1, FXR1, TIZ sheep anti-human IgG polyclonal antibody were optimized to establish a stable detected suspension array.(2)Sixty patients confirmed by pathological examination with ovarian cancer(ovarian cancer group)which treated in Affiliated Tumor Hospital of Guangxi Medical University, 30 patients with ovarian benign tumor(benign group)and 30 cases of healthy women(control group)were chosen between September 2003 and December 2003. Suspension array technology and ELISA method were used to detect expression of CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1 and TIZ IgG autoantibody contented in 3 groups of serum, then to compare the diagnostic efficiency and diagnostic accuracy of two methods(coefficient of variation between batch and batch). Results: (1)This research successfully established stable detecting system of CCL18, CXCL1, C1D, TM4SF1, FXR1 and TIZ IgG autoantibody. The best concentration of CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ antigen package were 8, 8, 12, 8, 4 and 8 μg/ml; the best detection of CCL18, CXCL1 biotin polyclonal antibody and C1D, TM4SF1, FXR1, TIZ sheep anti-huamne IgG polyclonal antibody were respectively 4, 2, 2, 4, 4 and 2 μg/ml.(2)Suspension array technology and ELISA method were used to detect CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1, TIZ IgG autoantibody of three groups in serum were similar(P>0.05).(3)The comparison of two methods in the diagnosis of efficiency: the diagnostic accuracy of two methods were 99.2%(119/120)and 94.2%(113/120), the difference was statistically significant(P=0.031). The sensitivity of the diagnosis of ovarian cancer of two methods were 100.0%(60/60)and 93.3%(56/60), specific degrees were 100.0%(59/59)and 93.4%(57/61), positive predictive value was 100.0%(60/60)and 93.3%(56/60), negative predictive value was 98.3%(59/60)and 95.0%(57/60), the difference was statistically significant(P<0.05).(4)The detected results of CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1, TIZ IgG autoantibody shown that the diagnostic accuracy of suspension array technology was superior to those of ELISA method(all P<0.05). Conclusion: The study has established the stable detection of suspension array technology, and the diagnostic efficiency and diagnostic accuracy was much better than that by ELISA.
Collapse
|
46
|
[Effects of ligustilide on the extracellular recombinant human heat shock protein 60 induced inflammatory reactions in the THP-1 cells and the related mechanisms]. ZHONGHUA XIN XUE GUAN BING ZA ZHI 2016; 44:793-798. [PMID: 27667279 DOI: 10.3760/cma.j.issn.0253-3758.2016.09.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigate the effects of ligustilide(LIG) on extracellular recombinant human heat shock protein 60 (HSP60) induced inflammatory reactions in the THP-1 cells and the related mechanisms. Methods: THP-1 cells were differentiated to macrophages by incubation with phorbol-12-myristate-13-acetate (PMA). The immunofluorescence method was used to screen the optimum transfection concentration of MyD88 siRNA.The macrophages were divided into six groups(n=3), including blank control(siRNA transfection reagent), model(siRNA transfection reagent+ HSP60 10 mg/L), negative control(MyD88 negative control+ HSP60 10 mg/L), LIG group(siRNA transfection reagent+ HSP60 10 mg/L+ LIG 20 mg/L), RNA interfering(RNAi) group(MyD88 siRNA+ HSP60 10 mg/L) and RNAi+ LIG group(MyD88 siRNA+ HSP60 10 mg/L+ LIG 20 mg/L). The protein expression level of MyD88 and phospho-nuclear factor-κB(p-NF-κB) in macrophages and the level of tumor necrosis factor-α(TNF-α) and interleukin-6(IL-6) in the culture supernatant were assessed by Western blot analyses or ELISA, respectively. Results: (1)The protein expression levels of MyD88 (1.196±0.125 vs. 0.341±0.063, P<0.01) and p-NF-κB(0.817±0.034 vs. 0.312±0.046, P<0.01) were significantly higher in the model group than those in the blank control group.The protein expression levels of MyD88(0.554±0.043) and p-NF-κB(0.538±0.063) in the RNAi group were significantly lower than those in the model group (all P<0.01) but significantly higher than those in the blank control group (all P<0.05). The protein expression levels of MyD88(0.694±0.087, P<0.05) and p-NF-κB(0.669±0.043, P<0.01)in the LIG group were markedly lower than those in the model group, but higher than those in the RNAi group (P<0.05) and the blank control group (P<0.01). The protein expression levels of MyD88(0.409±0.069) and p-NF-κB(0.395±0.046) in the RNAi+ LIG group were significantly lower than in the model group (all P<0.01) and in the LIG group(P<0.05 or 0.01), and were similar to the blank control group(P>0.05). The expression level of p-NF-κB in the RNAi+ LIG group was significantly lower than in the RNAi group (P<0.05). (2) The contents of TNF-α((312.24±28.69) ng/L vs. (5.99±1.03) ng/L, P<0.01) and IL-6((233.45±57.77) ng/L vs. (2.25±0.67) ng/L, P<0.01) were significantly higher in the model group than in the blank control group. The contents of TNF-α((235.66±25.12) ng/L) and IL-6((131.59±13.99) ng/L) were significantly lower in the RNAi group than in the model group (P<0.01). The contents of TNF-α((258.13±44.80) ng/L) and IL-6((175.92±28.27) ng/L) were also significantly lower in the LIG group than in the model group(P<0.05) while the content of IL-6 was significantly higher in the LIG group than in the RNAi group(P<0.01). The contents of TNF-α((88.57±16.10) ng/L) and IL-6((59.99±10.31) ng/L) were significantly lower in the RNAi+ LIG group than those in the model group, the RNAi group and the LIG group(P<0.05 or 0.01). Conclusions: The MyD88/NF-κB signaling pathway is one of the key signaling pathways of human HSP60 induced inflammation in THP-1 cells. Ligustilide could exhibit the anti-inflammatory effect probably by inhibiting the MyD88/NF-κB signaling pathway.
Collapse
|
47
|
Role of material loss and mode volume of plasmonic nanocavities for strong plasmon-exciton interactions. OPTICS EXPRESS 2016; 24:20373-81. [PMID: 27607644 DOI: 10.1364/oe.24.020373] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We investigate the role of material loss and mode volume of plasmonic nanostructures on strong plasmon-exciton coupling. We find that the field enhancement, and therefore loss, is not important for the magnitude of the Rabi splitting as such, but instead it is determined by the mode volume. Nevertheless, for reaching true strong coupling condition, that is, coupling greater than any dissipation, it is important to compromise losses. We also show that using such popular geometries as a dimer of two spheres or bow-tie nanoantennas, does not allow compressing the mode volume much in comparison to a single nanoparticle case, except for very narrow gaps, but rather it allows for efficient extraction of the mode out of the metal thus making it more accessible for excitons to interact with. Even more efficient mode extraction is achieved when high refractive index dielectric is placed in the gap. Our findings may find practical use for quantum plasmonics applications.
Collapse
|
48
|
Identification of novel and useful EST-SSR markers from de novo transcriptome sequence of wheat (Triticum aestivum L.). GENETICS AND MOLECULAR RESEARCH 2016; 15:gmr7509. [PMID: 26909990 DOI: 10.4238/gmr.15017509] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Simple sequence repeats (SSRs) are highly informative, polymorphic, and co-dominant Mendelian markers that provide an important genomic resource for genetic research. Recently, the use of large-scale transcriptome sequence has become a reliable and efficient approach for the identification and development of new EST-SSR markers. In this study, 8389 potential SSRs with a minimum of five repetitions for all motifs were identified from 121,210 unigenes. Gene ontology analysis indicated that the unigenes containing SSR loci participate in various biological processes of regulation, growth, development, metabolism, and apoptosis in wheat. As in many other plants, trinucleotide repeats were found to be the most abundant repeat units with a frequency of 62.33%. A subset of 300 EST-SSRs was randomly selected for the applicability of EST-SSRs to be evaluated. Of the 300 primer pairs tested, 177 (59%) yielded unambiguous PCR products among five wheat cultivars. Using the Chinese Spring nulli-tetrasomic line, 131 of the 177 EST-SSR primer pairs yielded products and 178 loci were found to be located on all the 21 wheat chromosomes. These findings suggest that the novel EST-SSR markers, as a basis for future genetic linkage and gene tagging analysis, are a valuable tool for genetic mapping, marker assisted selection, and comparative genome analysis.
Collapse
|
49
|
Directional Light Extinction and Emission in a Metasurface of Tilted Plasmonic Nanopillars. NANO LETTERS 2016; 16:98-104. [PMID: 26625299 DOI: 10.1021/acs.nanolett.5b03026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Plasmonic optical antennas and metamaterials with an ability to boost light-matter interactions for particular incidence or emission angles could find widespread use in solar harvesting, biophotonics, and in improving photon source performance at optical frequencies. However, directional plasmonic structures have generally large footprints or require complicated geometries and costly nanofabrication technologies. Here, we present a directional metasurface realized by breaking the out-of-plane symmetry of its individual elements: tilted subwavelength plasmonic gold nanopillars. Directionality is caused by the complex charge oscillation induced in each individual nanopillar, which essentially acts as a tilted dipole above a dielectric interface. The metasurface is homogeneous over a macroscopic area and it is fabricated by a combination of facile colloidal lithography and off-normal metal deposition. Fluorescence excitation and emission from dye molecules deposited on the metasurface is enhanced in specific directions determined by the tilt angle of the nanopillars. We envisage that these directional metasurfaces can be used as cost-effective substrates for surface-enhanced spectroscopies and a variety of nanophotonic applications.
Collapse
|
50
|
Abstract
Efficient and robust artificial nanomotors could provide a variety of exciting possibilities for applications in physics, biology and chemistry, including nanoelectromechanical systems, biochemical sensing, and drug delivery. However, the application of current man-made nanomotors is limited by their sophisticated fabrication techniques, low mechanical output power and severe environmental requirements, making their performance far below that of natural biomotors. Here we show that single-crystal gold nanorods can be rotated extremely fast in aqueous solutions through optical torques dominated by plasmonic resonant scattering of circularly polarized laser light with power as low as a few mW. The nanorods are trapped in 2D against a glass surface, and their rotational dynamics is highly dependent on their surface plasmon resonance properties. They can be kept continuously rotating for hours with limited photothermal side effects and they can be applied for detection of molecular binding with high sensitivity. Because of their biocompatibility, mechanical and thermal stability, and record rotation speeds reaching up to 42 kHz (2.5 million revolutions per minute), these rotary nanomotors could advance technologies to meet a wide range of future nanomechanical and biomedical needs in fields such as nanorobotics, nanosurgery, DNA manipulation and nano/microfluidic flow control.
Collapse
|