1
|
Kuck KH, Lebedev DS, Mikhaylov EN, Romanov A, Gellér L, Kalējs O, Neumann T, Davtyan K, On YK, Popov S, Bongiorni MG, Schlüter M, Willems S, Ouyang F. Catheter ablation or medical therapy to delay progression of atrial fibrillation: the randomized controlled atrial fibrillation progression trial (ATTEST). Europace 2021; 23:362-369. [PMID: 33330909 PMCID: PMC7947582 DOI: 10.1093/europace/euaa298] [Citation(s) in RCA: 148] [Impact Index Per Article: 37.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 09/28/2020] [Indexed: 12/24/2022] Open
Abstract
AIMS Delay of progression from paroxysmal to persistent atrial fibrillation (AF) is an important measure of long-term success of AF treatment. However, published data on the impact of catheter ablation on AF progression are limited. This study evaluates whether radiofrequency (RF) catheter ablation delays the progression of AF compared with antiarrhythmic drug (AAD) treatment using current AF management guidelines. METHODS This prospective, randomized, controlled, two-arm, open-label trial was conducted at 29 hospitals and medical centres across 13 countries. Patients were randomized 1 : 1 to RF ablation or AAD treatment. The primary endpoint was the rate of persistent AF/atrial tachycardia (AT) at 3 years. RESULTS After early study termination following slow enrolment, 255 (79%) of the planned 322 patients were enrolled (RF ablation, n = 128, AAD, n = 127); 36% of patients in the RF ablation group and 41% in the AAD group completed 3 years of follow-up. For the primary endpoint, the Kaplan-Meier estimate of the rate of persistent AF/AT at 3 years was significantly lower with RF ablation [2.4% (95% confidence interval (CI), 0.6-9.4%)] than with AAD therapy [17.5% (95% CI, 10.7-27.9%); one-sided P = 0.0009]. Patients ≥65 years were ∼4 times more likely to progress to persistent AF/AT than patients <65 years, suggesting RF ablation can delay disease progression [hazard ratio: 3.87 (95% CI, 0.88-17.00); P = 0.0727]. Primary adverse events were reported for eight patients in the RF ablation group. CONCLUSIONS Radiofrequency ablation is superior to guideline-directed AAD therapy in delaying the progression from paroxysmal to persistent AF.
Collapse
|
Randomized Controlled Trial |
4 |
148 |
2
|
Roselli C, Yu M, Nauffal V, Georges A, Yang Q, Love K, Weng LC, Delling FN, Maurya SR, Schrölkamp M, Tfelt-Hansen J, Hagège A, Jeunemaitre X, Debette S, Amouyel P, Guan W, Muehlschlegel JD, Body SC, Shah S, Samad Z, Kyryachenko S, Haynes C, Rienstra M, Le Tourneau T, Probst V, Roussel R, Wijdh-Den Hamer IJ, Siland JE, Knowlton KU, Jacques Schott J, Levine RA, Benjamin EJ, Vasan RS, Horne BD, Muhlestein JB, Benfari G, Enriquez-Sarano M, Natale A, Mohanty S, Trivedi C, Shoemaker MB, Yoneda ZT, Wells QS, Baker MT, Farber-Eger E, Michelena HI, Lundby A, Norris RA, Slaugenhaupt SA, Dina C, Lubitz SA, Bouatia-Naji N, Ellinor PT, Milan DJ. Genome-wide association study reveals novel genetic loci: a new polygenic risk score for mitral valve prolapse. Eur Heart J 2022; 43:1668-1680. [PMID: 35245370 PMCID: PMC9649914 DOI: 10.1093/eurheartj/ehac049] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 08/18/2021] [Accepted: 02/01/2022] [Indexed: 11/12/2022] Open
Abstract
AIMS Mitral valve prolapse (MVP) is a common valvular heart disease with a prevalence of >2% in the general adult population. Despite this high incidence, there is a limited understanding of the molecular mechanism of this disease, and no medical therapy is available for this disease. We aimed to elucidate the genetic basis of MVP in order to better understand this complex disorder. METHODS AND RESULTS We performed a meta-analysis of six genome-wide association studies that included 4884 cases and 434 649 controls. We identified 14 loci associated with MVP in our primary analysis and 2 additional loci associated with a subset of the samples that additionally underwent mitral valve surgery. Integration of epigenetic, transcriptional, and proteomic data identified candidate MVP genes including LMCD1, SPTBN1, LTBP2, TGFB2, NMB, and ALPK3. We created a polygenic risk score (PRS) for MVP and showed an improved MVP risk prediction beyond age, sex, and clinical risk factors. CONCLUSION We identified 14 genetic loci that are associated with MVP. Multiple analyses identified candidate genes including two transforming growth factor-β signalling molecules and spectrin β. We present the first PRS for MVP that could eventually aid risk stratification of patients for MVP screening in a clinical setting. These findings advance our understanding of this common valvular heart disease and may reveal novel therapeutic targets for intervention.
Collapse
|
Meta-Analysis |
3 |
41 |
3
|
Natale A, Zeppenfeld K, Della Bella P, Liu X, Sabbag A, Santangeli P, Sommer P, Sticherling C, Zhang X, Di Biase L. Twenty-five years of catheter ablation of ventricular tachycardia: a look back and a look forward. Europace 2023; 25:euad225. [PMID: 37622589 PMCID: PMC10451002 DOI: 10.1093/europace/euad225] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 07/14/2023] [Indexed: 08/26/2023] Open
Abstract
This article will discuss the past, present, and future of ventricular tachycardia ablation and the continuing contribution of the Europace journal as the platform for publication of milestone research papers in this field of ventricular tachycardia ablation.
Collapse
|
review-article |
2 |
32 |
4
|
Rajendra A, Hunter TD, Morales G, Osorio J. Prospective implementation of a same-day discharge protocol for catheter ablation of paroxysmal atrial fibrillation. J Interv Card Electrophysiol 2020; 62:419-425. [PMID: 33219896 PMCID: PMC7679791 DOI: 10.1007/s10840-020-00914-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Accepted: 11/08/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE Overnight stays associated with catheter ablation (CA) for paroxysmal atrial fibrillation (PAF) account for a significant proportion of treatment cost. Same-day discharge (SDD) after CA may be attractive to both patients and hospitals, especially in light of current restrictions on overnight stays due to COVID-19. This study reports on the selection criteria, protocol, and safety of SDD after CA of PAF. METHODS Patients undergoing CA for PAF were evaluated to assess the risk of groin, respiratory, cardiac, or bleeding complications. SDD eligibility criteria were stable anticoagulation with no bleeding history, systolic heart failure, respiratory conditions, or interventional procedures within 60 days, and recommended BMI < 35. Patient proximity to the hospital was also considered. Anesthesia with propofol was used, and ablations were performed with a contact force catheter. Patients rested for 6 h post-procedure and then ambulated over 1-2 h. Discharge followed if they were stable without evidence of complications. A nurse called all patients the following morning to elicit evidence of complications. RESULTS Of 44 planned SDD procedures between April 2017 and June 2018, 41 resulted in SDD after 7.2 ± 1.0 h, 2 patients stayed overnight for observation, and one by choice. Average age was 59 ± 10 years with CHA2DS2-VASc of 1.6 ± 1.1. No SDD-related complications occurred, and no return visits resulted from the follow-up calls. CONCLUSION Appropriate low-risk patients identified by well-defined clinical criteria can be safely discharged the same day after CA for PAF. Evaluation in a larger population across different centers is required for generalizability of this SDD protocol.
Collapse
|
Journal Article |
5 |
22 |
5
|
Noujaim C, Lim C, Mekhael M, Feng H, Chouman N, Younes H, Assaf A, Shan B, Shamaileh G, Dhore-Patil A, Nelson D, Lanier B, Makan N, Marrouche N, Donnellan E. Identifying the prognostic significance of early arrhythmia recurrence during the blanking period and the optimal blanking period duration: insights from the DECAAF II study. Europace 2023; 25:euad173. [PMID: 37337683 PMCID: PMC10292951 DOI: 10.1093/europace/euad173] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 05/29/2023] [Accepted: 06/12/2023] [Indexed: 06/21/2023] Open
Abstract
OBJECTIVE Early atrial arrhythmia recurrence following atrial fibrillation (AF) ablation is common. Current guidelines promulgate a 3-month blanking period. We hypothesize that early atrial arrhythmia recurrence during the blanking period may predict longer-term ablation outcomes. METHODS AND RESULTS A total of 688 patients with persistent AF undergoing catheter ablation were included in the DECAAF II trial database. The primary endpoint of the study was the first confirmed recurrence of atrial arrhythmia. Recurrence was also monitored during the 90-day blanking period. A total of 287 patients experienced recurrent atrial arrhythmia during the blanking period, while 401 remained in sinus rhythm. Rates of longer-term arrhythmia recurrence were substantially higher among those who developed recurrence during the blanking period compared to those who remained in sinus rhythm throughout the blanking period (68% vs. 32%, P < 0.001). The study cohort was divided into three groups according to the timing of arrhythmia recurrence during the blanking period. Of those who had recurrent arrhythmia during the first month of the blanking period (Group 1), 43.9% experienced longer-term recurrence, compared to 61.6% who recurred during the second month of the blanking period (Group 2), and 93.3% of those who had arrhythmia recurrence during the third month (Group 3, P < 0.001). The risk of recurrent arrhythmia was highest in Group 3 (HR = 10.15), followed by Group 2 (HR = 2.35) and Group 1 (HR = 1.5). Receiver operating characteristic analysis was performed to assess the relationship between the timing of arrhythmia recurrence and the primary outcome (AUC = 0.746, P < 0.001). The optimal blanking period duration was identified as 34 days. Atrial fibrillation burden determined by smartphone electrocardiogram technology over the 18 months follow-up period was significantly higher in Group 3 (29%) compared to Groups 1 (6%) and 2 (7%) and in patients who stayed in sinus rhythm during the blanking period (5%) (P < 0.0001). CONCLUSION Early atrial arrhythmia recurrence during the blanking period, particularly during the third month, is significantly associated with later recurrence. Although a blanking period is warranted, it should be abbreviated.
Collapse
|
Clinical Trial |
2 |
17 |
6
|
Assaf A, Mekhael M, Noujaim C, Chouman N, Younes H, Feng H, ElHajjar A, Shan B, Kistler P, Kreidieh O, Marrouche N, Donnellan E. Effect of fibrosis regionality on atrial fibrillation recurrence: insights from DECAAF II. Europace 2023; 25:euad199. [PMID: 37428891 PMCID: PMC10519620 DOI: 10.1093/europace/euad199] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Accepted: 06/06/2023] [Indexed: 07/12/2023] Open
Abstract
AIMS The amount of fibrosis in the left atrium (LA) predicts atrial fibrillation (AF) recurrence after catheter ablation (CA). We aim to identify whether regional variations in LA fibrosis affect AF recurrence. METHODS AND RESULTS This post hoc analysis of the DECAAF II trial includes 734 patients with persistent AF undergoing first-time CA who underwent late gadolinium enhancement magnetic resonance imaging (LGE-MRI) within 1 month prior to ablation and were randomized to MRI-guided fibrosis ablation in addition to standard pulmonary vein isolation (PVI) or standard PVI only. The LA wall was divided into seven regions: anterior, posterior, septal, lateral, right pulmonary vein (PV) antrum, left PV antrum, and left atrial appendage (LAA) ostium. Regional fibrosis percentage was defined as a region's fibrosis prior to ablation divided by total LA fibrosis. Regional surface area percentage was defined as an area's surface area divided by the total LA wall surface area before ablation. Patients were followed up for a year with single-lead electrocardiogram (ECG) devices. The left PV had the highest regional fibrosis percentage (29.30 ± 14.04%), followed by the lateral wall (23.23 ± 13.56%), and the posterior wall (19.80 ± 10.85%). The regional fibrosis percentage of the LAA was a significant predictor of AF recurrence post-ablation (odds ratio = 1.017, P = 0.021), and this finding was only preserved in patients receiving MRI-guided fibrosis ablation. Regional surface area percentages did not significantly affect the primary outcome. CONCLUSION We have confirmed that atrial cardiomyopathy and remodelling are not a homogenous process, with variations in different regions of the LA. Atrial fibrosis does not uniformly affect the LA, and the left PV antral region has more fibrosis than the rest of the wall. Furthermore, we identified regional fibrosis of the LAA as a significant predictor of AF recurrence post-ablation in patients receiving MRI-guided fibrosis ablation in addition to standard PVI.
Collapse
|
Randomized Controlled Trial |
2 |
15 |
7
|
Barmano N, Charitakis E, Kronstrand R, Walfridsson U, Karlsson JE, Walfridsson H, Nystrom FH. The association between alcohol consumption, cardiac biomarkers, left atrial size and re-ablation in patients with atrial fibrillation referred for catheter ablation. PLoS One 2019; 14:e0215121. [PMID: 30970005 PMCID: PMC6457637 DOI: 10.1371/journal.pone.0215121] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 03/28/2019] [Indexed: 12/14/2022] Open
Abstract
Background Information on alcohol consumption in patients undergoing radiofrequency ablation (RFA) of atrial fibrillation (AF) is often limited by the reliance on self-reports. The aim of this study was to describe the long-term alcohol consumption, measured as ethyl glucuronide in hair (hEtG), in patients undergoing RFA due to AF, and to examine potential associations with cardiac biomarkers, left atrial size and re-ablation within one year after the initial RFA. Methods The amount of hEtG was measured in patients referred for RFA, and a cut-off of 7 pg/mg was used. N-terminal pro B-type natriuretic peptide (NT-proBNP) and the mid-regional fragment of pro atrial natriuretic peptide (MR-proANP) were examined and maximum left atrium volume index (LAVI) was measured. The number of re-ablations was examined up to one year after the initial RFA. Analyses were stratified by gender, and adjusted for age, systolic blood pressure, body mass index, presence of heart failure and heart rhythm for analyses regarding NT-proBNP, MR-proANP and LAVI and heart rhythm being replaced by type of AF for analyses regarding re-ablation. Results In total, 192 patients were included in the study. Median (25th– 75th percentile) NT-proBNP in men with hEtG ≥ 7 vs. < 7 pg/mg was 250 (96–695) vs. 130 (49–346) pg/ml (p = 0.010), and in women it was 230 (125–480) vs. 230 (125–910) pg/ml (p = 0.810). Median MR-proANP in men with hEtG ≥ 7 vs. < 7 pg/mg was 142 (100–224) vs. 117 (83–179) pmol/l (p = 0.120) and in women it was 139 (112–206) vs. 153 (93–249) pmol/l (p = 0.965). The median of maximum LAVI was 30.1 (26.7–33.9) vs. 25.8 (21.4–32.0) ml/m2 (p = 0.017) in men, and 25.0 (18.9–29.6) vs. 25.7 (21.7–34.6) ml/m2 (p = 0.438) in women, with hEtG ≥ 7 vs. < 7 pg/ml, respectively. Adjusted analyses showed similar results, except for MR-proANP turning out significant in men with hEtG ≥ 7 vs. < 7 pg/mg (p = 0.047). The odds ratio of having a re-ablation was 3.5 (95% CI 1.3–9.6, p = 0.017) in men with hEtG ≥ 7 vs. < 7 pg/mg, while there was no significant difference in women. Conclusions In male patients with AF and hEtG ≥ 7 pg/mg, NT-proBNP and MR-proANP were higher, LA volumes larger, and there was a higher rate of re-ablations, as compared to men with hEtG < 7 pg/mg. This implies that men with an alcohol consumption corresponding to an hEtG-value ≥ 7, have a higher risk for LA remodelling that could potentially lead to a deterioration of the AF situation.
Collapse
|
Research Support, Non-U.S. Gov't |
6 |
14 |
8
|
Bordignon S, My I, Tohoku S, Rillig A, Schaack D, Chen S, Reißmann B, Urbanek L, Hirokami J, Efe T, Ebrahimi R, Butt M, Ouyang F, Chun JKR, Metzner A, Schmidt B. Efficacy and safety in patients treated with a novel radiofrequency balloon: a two centres experience from the AURORA collaboration. Europace 2023; 25:euad106. [PMID: 37116126 PMCID: PMC10228597 DOI: 10.1093/europace/euad106] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 03/03/2023] [Indexed: 04/30/2023] Open
Abstract
AIMS A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.
Collapse
|
research-article |
2 |
10 |
9
|
Varley AL, Kreidieh O, Godfrey BE, Whitmire C, Thorington S, D'Souza B, Kang S, Hebsur S, Ravindran BK, Zishiri E, Gidney B, Sellers MB, Singh D, Salam T, Metzl M, Ro A, Nazari J, Fisher WG, Costea A, Magnano A, Oza S, Morales G, Rajendra A, Silverstein J, Zei PC, Osorio J. A prospective multi-site registry of real-world experience of catheter ablation for treatment of symptomatic paroxysmal and persistent atrial fibrillation (Real-AF): design and objectives. J Interv Card Electrophysiol 2021; 62:487-494. [PMID: 34212280 PMCID: PMC8249214 DOI: 10.1007/s10840-021-01031-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 06/24/2021] [Indexed: 12/16/2022]
Abstract
Purpose Catheter ablation has become a mainstay therapy for atrial fibrillation (AF) with rapid innovation over the past decade. Variability in ablation techniques may impact efficiency, safety, and efficacy; and the ideal strategy is unknown. Real-world evidence assessing the impact of procedural variations across multiple operators may provide insight into these questions. The Real-world Experience of Catheter Ablation for the Treatment of Symptomatic Paroxysmal (PAF) and Persistent (PsAF) Atrial Fibrillation registry (Real-AF) is a multicenter prospective registry that will enroll patients at high volume centers, including academic institutions and private practices, with operators performing ablations primarily with low fluoroscopy when possible. The study will also evaluate the contribution of advent in technologies and workflows to real-world clinical outcomes. Methods Patients presenting at participating centers are screened for enrollment. Data are collected at the time of procedure, 10–12 weeks, and 12 months post procedure and include patient and detailed procedural characteristics, with short and long-term outcomes. Arrhythmia recurrences are monitored through standard of care practice which includes continuous rhythm monitoring at 6 and 12 months, event monitors as needed for routine care or symptoms suggestive of recurrence, EKG performed at every visit, and interrogation of implanted device or ILR when applicable. Results Enrollment began in January 2018 with a single site. Additional sites began enrollment in October 2019. Through May 2021, 1,243 patients underwent 1,269 procedures at 13 institutions. Our goal is to enroll 4000 patients. Discussion Real-AF’s multiple data sources and detailed procedural information, emphasis on high volume operators, inclusion of low fluoroscopy operators, and use of rigorous standardized follow-up methodology allow systematic documentation of clinical outcomes associated with changes in ablation workflow and technologies over time. Timely data sharing may enable real-time quality improvements in patient care and delivery. Trial registration Clinicaltrials.gov: NCT04088071 (registration date: September 12, 2019) Supplementary Information The online version contains supplementary material available at 10.1007/s10840-021-01031-w.
Collapse
|
Journal Article |
4 |
9 |
10
|
Begg GA, O’Neill J, Sohaib A, McLean A, Pepper CB, Graham LN, Hogarth AJ, Page SP, Gillott RG, Hill N, Walshaw J, Schilling RJ, Kanagaratnam P, Tayebjee MH. Multicentre randomised trial comparing contact force with electrical coupling index in atrial flutter ablation (VERISMART trial). PLoS One 2019; 14:e0212903. [PMID: 30943196 PMCID: PMC6447159 DOI: 10.1371/journal.pone.0212903] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Accepted: 02/09/2019] [Indexed: 11/30/2022] Open
Abstract
Introduction Electrical coupling index (ECI) and contact force (CF) have been developed to aid lesion formation during catheter ablation. ECI measures tissue impedance and capacitance whilst CF measures direct contact. The aim was to determine whether the presence of catheter / tissue interaction information, such as ECI and CF, reduce time to achieve bidirectional cavotricuspid isthmus block during atrial flutter (AFL) ablation. Methods Patients with paroxysmal or persistent AFL were randomised to CF visible (range 5-40g), CF not visible, ECI visible (change of 12%) or ECI not visible. Follow-up occurred at 3 and 6 months and included a 7 day ECG recording. The primary endpoint was time to bidirectional cavotricuspid isthmus block. Results 114 patients were randomised, 16 were excluded. Time to bidirectional block was significantly shorter when ECI was visible (median 30.0 mins (IQR 31) to median 10.5mins (IQR 12) p 0.023) versus ECI not visible. There was a trend towards a shorter time to bidirectional block when CF was visible. Higher force was applied when CF was visible (median 9.03g (IQR 7.4) vs. 11.3g (5.5) p 0.017). There was no difference in the acute recurrence of conduction between groups. The complication rate was 2%, AFL recurrence was 1.1% and at 6 month follow-up, 12% had atrial fibrillation. Conclusion The use of tissue contact information during AFL ablation was associated with reduced time taken to achieve bidirectional block when ECI was visible. Contact force data improved contact when visible with a trend towards a reduction in the procedural endpoint. ClinicalTrials.gov trial identifier: NCT02490033.
Collapse
|
Research Support, Non-U.S. Gov't |
6 |
7 |
11
|
Lemoine MD, Obergassel J, Jaeckle S, Nies M, Taraba S, Mencke C, Rieß J, My I, Rottner L, Moser F, Ismaili D, Reißmann B, Ouyang F, Kirchhof P, Rillig A, Metzner A. Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures. Europace 2024; 26:euae221. [PMID: 39166530 PMCID: PMC11363872 DOI: 10.1093/europace/euae221] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2024] [Revised: 08/01/2024] [Accepted: 08/08/2024] [Indexed: 08/23/2024] Open
Abstract
AIMS Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI. METHODS AND RESULT A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation. CONCLUSION During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar.
Collapse
|
Comparative Study |
1 |
6 |
12
|
Nguyên UC, Maffessanti F, Mafi-Rad M, Conte G, Zeemering S, Regoli F, Caputo ML, van Stipdonk AMW, Bekkers SCAM, Suerder D, Moccetti T, Krause R, Prinzen FW, Vernooy K, Auricchio A. Evaluation of the use of unipolar voltage amplitudes for detection of myocardial scar assessed by cardiac magnetic resonance imaging in heart failure patients. PLoS One 2017; 12:e0180637. [PMID: 28678875 PMCID: PMC5498065 DOI: 10.1371/journal.pone.0180637] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2017] [Accepted: 06/19/2017] [Indexed: 11/23/2022] Open
Abstract
Background Validation of voltage-based scar delineation has been limited to small populations using mainly endocardial measurements. The aim of this study is to compare unipolar voltage amplitudes (UnipV) with scar on delayed enhancement cardiac magnetic resonance imaging (DE-CMR). Methods Heart failure patients who underwent DE-CMR and electro-anatomic mapping were included. Thirty-three endocardial mapped patients and 27 epicardial mapped patients were investigated. UnipV were computed peak-to-peak. Electrograms were matched with scar extent of the corresponding DE-CMR segment using a 16-segment/slice model. Non-scar was defined as 0% scar, while scar was defined as 1–100% scar extent. Results UnipVs were moderately lower in scar than in non-scar (endocardial 7.1 [4.6–10.6] vs. 10.3 [7.4–14.2] mV; epicardial 6.7 [3.6–10.5] vs. 7.8 [4.2–12.3] mV; both p<0.001). The correlation between UnipV and scar extent was moderate for endocardial (R = -0.33, p<0.001), and poor for epicardial measurements (R = -0.07, p<0.001). Endocardial UnipV predicted segments with >25%, >50% and >75% scar extent with AUCs of 0.72, 0.73 and 0.76, respectively, while epicardial UnipV were poor scar predictors, independent of scar burden (AUC = 0.47–0.56). UnipV in non-scar varied widely between patients (p<0.001) and were lower in scar compared to non-scar in only 9/22 (41%) endocardial mapped patients and 4/19 (21%) epicardial mapped patients with scar. Conclusion UnipV are slightly lower in scar compared to non-scar. However, significant UnipV differences between and within patients and large overlap between non-scar and scar limits the reliability of accurate scar assessment, especially in epicardial measurements and in segments with less than 75% scar extent.
Collapse
|
Journal Article |
8 |
6 |
13
|
Sousa PA, Barra S, Saleiro C, Khoueiry Z, Adão L, Primo J, Lagrange P, Lebreiro A, Fonseca P, Pereira M, Puga L, Oliveiros B, Elvas L, Gonçalves L. Ostial vs. wide area circumferential ablation guided by the Ablation Index in paroxysmal atrial fibrillation. Europace 2023; 25:euad160. [PMID: 37345859 PMCID: PMC10286571 DOI: 10.1093/europace/euad160] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 05/23/2023] [Indexed: 06/23/2023] Open
Abstract
AIMS Pulmonary vein isolation (PVI) guided by the Ablation Index (AI) has shown high acute and mid-term efficacy in the treatment of paroxysmal atrial fibrillation (AF). Previous data before the AI-era had suggested that wide-area circumferential ablation (WACA) was preferable to ostial ablation. However, with the use of AI, we hypothesize that ostial circumferential ablation is non-inferior to WACA and can improve outcomes in paroxysmal AF. METHODS AND RESULTS Prospective, multicentre, non-randomized, non-inferiority study of consecutive patients were referred for paroxysmal AF ablation from January 2020 to September 2021. All procedures were performed using the AI software, and patients were separated into two different groups: WACA vs. ostial circumferential ablation. Acute reconnection, procedural data, and 1-year arrhythmia recurrence were assessed. During the enrolment period, 162 patients (64% males, mean age of 60 ± 11 years) fulfilled the study inclusion criteria-81 patients [304 pulmonary vein (PV)] in the WACA group and 81 patients (301 PV) in the ostial group. Acute PV reconnection was identified in 7.9% [95% confidence interval (CI), 4.9-11.1%] of PVs in the WACA group compared with 3.3% (95% CI, 1.8-6.1%) of PVs in the ostial group [P < 0.001 for non-inferiority; adjusted odds ratio 0.51 (95% CI, 0.23-0.83), P = 0.05]. Patients in the WACA group had longer ablation (35 vs. 29 min, P = 0.001) and procedure (121 vs. 102 min, P < 0.001) times. No significant difference in arrhythmia recurrence was seen at 1-year of follow-up [11.1% in WACA vs. 9.9% in ostial, hazard ratio 1.13 (95% CI, 0.44-1.94), P = 0.80 for superiority]. CONCLUSION In paroxysmal AF patients treated with tailored AI-guided PVI, ostial circumferential ablation is not inferior to WACA with regard to acute PV reconnection, while allowing quicker procedures with less ablation time.
Collapse
|
research-article |
2 |
6 |
14
|
Samuel M, Rivard L, Nault I, Gula L, Essebag V, Parkash R, Sterns LD, Khairy P, Sapp JL. Comparative effectiveness of ventricular tachycardia ablation vs. escalated antiarrhythmic drug therapy by location of myocardial infarction: a sub-study of the VANISH trial. Europace 2022; 24:948-958. [PMID: 34964475 PMCID: PMC9282915 DOI: 10.1093/europace/euab298] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 11/16/2021] [Indexed: 12/31/2022] Open
Abstract
AIMS Complexity of the ventricular tachycardia (VT) substrate and the size and thickness of infarction area border zones differ based on location of myocardial infarctions (MIs). These differences may translate into heterogeneity in the effectiveness of treatments. This study aims to examine the influence of infarct location on the effectiveness of VT ablation in comparison with escalated pharmacological therapy in patients with prior MI and antiarrhythmic drug (AAD)-refractory VT. METHODS AND RESULTS VANISH trial participants were categorized based on the presence or absence of an inferior MI scar. Inverse probability of treatment weighted Cox models were calculated for each subgroup. Of 259 randomized patients (median age 69.8 years, 7.0% women), 135 had an inferior MI and 124 had a non-inferior MI. Among patients with an inferior MI, no statistically significant difference in the composite primary outcome of all-cause mortality, appropriate implantable cardioverter-defibrillator (ICD) shock, and VT storm was detected between treatment arms [adjusted hazard ratio (aHR) 0.80, 95% confidence interval (CI) 0.51-1.20]. In contrast, patients with non-inferior MIs had a statistically significant reduction in the incidence of the primary outcome with ablation (aHR 0.48, 95% CI 0.27-0.86). In a sensitivity analysis of anterior MI patients (n = 83), a trend towards a reduction in the primary outcome with ablation was detected (aHR 0.50, 95% CI 0.23-1.09). CONCLUSION The effectiveness of VT ablation versus escalated AADs varies based on the location of the MI. Patients with MI scars located only in non-inferior regions of the ventricles derive greater benefit from VT ablation in comparison to escalation of AADs in reducing VT-related events.
Collapse
|
Randomized Controlled Trial |
3 |
5 |
15
|
Wallet J, Kimura Y, Blom NA, Man S, Jongbloed MRM, Zeppenfeld K. The R″ wave in V1 and the negative terminal QRS vector in aVF combine to a novel 12-lead ECG algorithm to identify slow conducting anatomical isthmus 3 in patients with tetralogy of Fallot. Europace 2023; 25:euad139. [PMID: 37314194 PMCID: PMC10265971 DOI: 10.1093/europace/euad139] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Accepted: 05/18/2023] [Indexed: 06/15/2023] Open
Abstract
AIMS Patients with repaired tetralogy of Fallot (rTOF) have an increased risk of ventricular tachycardia (VT), with slow conducting anatomical isthmus (SCAI) 3 as dominant VT substrate. In patients with right bundle branch block (RBBB), SCAI 3 leads to local activation delay with a shift of terminal RV activation towards the lateral RV outflow tract which may be detected by terminal QRS vector changes on sinus rhythm electrocardiogram (ECG). METHODS AND RESULTS Consecutive rTOF patients aged ≥16 years with RBBB who underwent electroanatomical mapping at our institution between 2017-2022 and 2010-2016 comprised the derivation and validation cohort, respectively. Forty-six patients were included in the derivation cohort (aged 40±15 years, QRS duration 165±23 ms). Among patients with SCAI 3 (n = 31, 67%), 17 (55%) had an R″ in V1, 18 (58%) had a negative terminal QRS portion (NTP) ≥80 ms in aVF, and 12 (39%) had both ECG characteristics, compared to only 1 (7%), 1 (7%), and 0 patient without SCAI, respectively.Combining R″ in V1 and/or NTP ≥80 ms in aVF into a diagnostic algorithm resulted in a sensitivity of 74% and specificity of 87% in detecting SCAI 3. The inter-observer agreement for the diagnostic algorithm was 0.875. In the validation cohort [n = 33, 18 (55%) with SCAI 3], the diagnostic algorithm had a sensitivity of 83% and specificity of 80% for identifying SCAI 3. CONCLUSION A sinus rhythm ECG-based algorithm including R″ in V1 and/or NTP ≥80 ms in aVF can identify rTOF patients with a SCAI 3 and may contribute to non-invasive risk stratification for VT.
Collapse
|
research-article |
2 |
5 |
16
|
König S, Wohlrab L, Leiner J, Pellissier V, Nitsche A, Darma A, Hilbert S, Nedios S, Seewöster T, Dinov B, Hindricks G, Bollmann A. Patient perspectives on same-day discharge following catheter ablation for atrial fibrillation: results from a patient survey as part of the monocentric FAST AFA trial. Europace 2023; 25:euad262. [PMID: 37656979 PMCID: PMC10492224 DOI: 10.1093/europace/euad262] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Accepted: 08/11/2023] [Indexed: 09/03/2023] Open
Abstract
AIMS Same-day discharge (SDD) following catheter ablation (CA) of atrial fibrillation (AF) was already introduced in selected facilities in Europe, but a widespread implementation has not yet succeeded. Data on patients' perspectives are lacking. Therefore, we conducted a survey to address patients' beliefs towards SDD and identify variables that are associated with their evaluation. METHODS AND RESULTS As part of the prospective, monocentric FAST AFA trial, patients aged ≥20 years undergoing left atrial CA for AF were asked to participate in the survey consisting of a study-specific questionnaire, the AF knowledge scale, and pre-defined patient-reported outcome measures. The study cohort was stratified based on SDD willingness, and a logistic regression analysis was used to identify predictors for patients' valuation. Between 26 July 2021 and 01 July 2022, 256 of 376 screened patients consented to study participation of whom 248 (mean age 61.8 years, 33.9% female) completed the SDD survey. Of them, 50.0% were willing to have SDD concepts integrated into their clinical course with increased patient comfort (27.5%), shorter waiting times (14.6%), and a cost-efficient treatment (14.0%) being imaginable benefits. In contrast, expressed concerns included uncertainties with occurring complaints (50.6%), the insufficient recognition (47.8%), and treatment (48.9%) of complications. European Heart Rhythm Association class at baseline and inpatient treatments within the preceding year were predictors for SDD willingness whereas comorbidity burden or AF knowledge were not. CONCLUSION We provide a detailed survey expressing patients' beliefs towards SDD following left atrial CA. Our findings may facilitate adequate patient selection to improve the future implementation of SDD programs in suitable cohorts.
Collapse
|
Clinical Trial |
2 |
5 |
17
|
Starreveld R, Knops P, Roos-Serote M, Kik C, Bogers AJJC, Brundel BJJM, de Groot NMS. The Impact of Filter Settings on Morphology of Unipolar Fibrillation Potentials. J Cardiovasc Transl Res 2020; 13:953-964. [PMID: 32410210 PMCID: PMC7708344 DOI: 10.1007/s12265-020-10011-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 04/17/2020] [Indexed: 12/16/2022]
Abstract
Using unipolar atrial electrogram morphology as guidance for ablative therapy is regaining interest. Although standardly used in clinical practice during ablative therapy, the impact of filter settings on morphology of unipolar AF potentials is unknown. Thirty different filters were applied to 2,557,045 high-resolution epicardial AF potentials recorded from ten patients. Deflections with slope ≤ - 0.05 mV/ms and amplitude ≥ 0.3 mV were marked. High-pass filtering decreased the number of detected potentials, deflection amplitude, and percentage of fractionated potentials (≥ 2 deflections) as well as fractionation delay time (FDT) and increased percentage of single potentials. Low-pass filtering decreased the number of potentials, percentage of fractionated potentials, whereas deflection amplitude, percentage of single potentials, and FDT increased. Notch filtering (50 Hz) decreased the number of potentials and deflection amplitude, whereas the percentage of complex fractionated potentials (≥ 3 deflections) increased. Filtering significantly impacted morphology of unipolar fibrillation potentials, becoming a potential source of error in identification of ablative targets. Graphical Abstract Impact of filtering on morphology of unipolar AF potentials. High-pass, low-pass and notch filters were applied to 2,557,045 high-resolution epicardial AF potentials recorded from ten patients. Filtering significantly impacted AF potential morphology, i.e., number of detected potentials, peak-to-peak amplitude, number of deflections, and fractionation delay time. CFP, complex fractionated potential (≥ 3 deflections); DP, double potential (two deflections); FDT, fractionation delay time; SP, single potential (one deflection).
Collapse
|
Observational Study |
5 |
4 |
18
|
Ávila P, Berruezo A, Jiménez-Candil J, Tercedor L, Calvo D, Arribas F, Fernández-Portales J, Merino JL, Hernández-Madrid A, Fernández-Avilés F, Arenal Á. Bayesian analysis of the Substrate Ablation vs. Antiarrhythmic Drug Therapy for Symptomatic Ventricular Tachycardia trial. Europace 2023; 25:euad181. [PMID: 37366571 PMCID: PMC10326301 DOI: 10.1093/europace/euad181] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Accepted: 06/21/2023] [Indexed: 06/28/2023] Open
Abstract
BACKGROUND AND AIMS Bayesian analyses can provide additional insights into the results of clinical trials, aiding in the decision-making process. We analysed the Substrate Ablation vs. Antiarrhythmic Drug Therapy for Symptomatic Ventricular Tachycardia (SURVIVE-VT) trial using Bayesian survival models. METHODS AND RESULTS The SURVIVE-VT trial randomized patients with ischaemic cardiomyopathy and monomorphic ventricular tachycardia (VT) to catheter ablation or antiarrhythmic drugs (AAD) as a first-line strategy. The primary outcome was a composite of cardiovascular death, appropriate implantable cardioverter-defibrillator shocks, unplanned heart failure hospitalizations, or severe treatment-related complications. We used informative, skeptical, and non-informative priors with different probabilities of large effects to compute the posterior distributions using Markov Chain Monte Carlo methods. We calculated the probabilities of hazard ratios (HR) being <1, <0.9, and <0.75, as well as 2-year survival estimates. Of the 144 randomized patients, 71 underwent catheter ablation and 73 received AAD. Regardless of the prior, catheter ablation had a >98% probability of reducing the primary outcome (HR < 1) and a >96% probability of achieving a reduction of >10% (HR < 0.9). The probability of a >25% (HR < 0.75) reduction of treatment-related complications was >90%. Catheter ablation had a high probability (>93%) of reducing incessant/slow undetected VT/electric storm, unplanned hospitalizations for ventricular arrhythmias, and overall cardiovascular admissions > 25%, with absolute differences of 15.2%, 21.2%, and 20.2%, respectively. CONCLUSION In patients with ischaemic cardiomyopathy and VT, catheter ablation as a first-line therapy resulted in a high probability of reducing several clinical outcomes compared to AAD. Our study highlights the value of Bayesian analysis in clinical trials and its potential for guiding treatment decisions. TRIAL REGISTRATION ClinicalTrials.gov identifier: NCT03734562.
Collapse
|
Randomized Controlled Trial |
2 |
4 |
19
|
Langmuur SJJ, Taverne YJHJ, van Schie MS, Bogers AJJC, de Groot NMS. Optimization of intra-operative electrophysiological localization of the ligament of Marshall. Front Cardiovasc Med 2022; 9:1030064. [PMID: 36407441 PMCID: PMC9669368 DOI: 10.3389/fcvm.2022.1030064] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022] Open
Abstract
Background The ligament of Marshall (LOM) may play a role in the pathophysiology of several tachyarrhythmias and accurate electrophysiological localization of this structure is crucial for effective ablation therapy. This study therefore quantifies electrophysiological properties of the LOM, and identifies which electrogram (EGM) recording (uni- or bipolar) and processing technologies [local activation time (LAT) and/or voltage mapping] are most suitable for accurate localization of the LOM. Methods The LOM was electrophysiologically identified in 19 patients (mean age 66 ± 14 years; 12 male) undergoing elective cardiac surgery using intra-operative high-density epicardial mapping, to quantify and visualize EGM features during sinus rhythm. Results Only a third of LOM potentials that were visualized using unipolar EGMs, were still visible in bipolar activation maps. Unipolar LOM potentials had lower voltages (P50: LOM: 1.51 (0.42–4.29) mV vs. left atrium (LA): 8.34 (1.50–17.91) mV, p < 0.001), less steep slopes (P50: LOM: –0.48 (–1.96 to –0.17) V/s vs. LA: –1.24 (–2.59 to –0.21) V/s, p < 0.001), and prolonged activation duration (LOM: 20 (7.5–30.5) ms vs. LA: 16.5 (6–28) ms, p = 0.008) compared to LA potentials. Likewise, bipolar LOM voltages were also smaller (P50: LOM: 1.54 (0.48–3.28) mV vs. LA: 3.12 (0.50–7.19) mV, p < 0.001). Conclusion The LOM was most accurately localized in activation and voltage maps by using unipolar EGMs with annotation of primary deflections in case of single potentials and secondary deflections in case of double or fractionated potentials.
Collapse
|
|
3 |
3 |
20
|
El Hajjar AH, Huang C, Zhang Y, Mekhael M, Noujaim C, Dagher L, Nedunchezhian S, Pottle C, Kholmovski E, Ayoub T, Dhorepatil A, Barakat M, Yamaguchi T, Chelu M, Marrouche N. Acute Lesion Imaging in Predicting Chronic Tissue Injury in the Ventricles. Front Cardiovasc Med 2022; 8:791217. [PMID: 35155604 PMCID: PMC8831749 DOI: 10.3389/fcvm.2021.791217] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 12/07/2021] [Indexed: 11/26/2022] Open
Abstract
Background Chronic lesion formation after cardiac tissue ablation is an important indicator for procedural outcome. Moreover, there is a lack of knowledge regarding the features that predict chronic lesion formation. Objective The aim of this study is to determine whether acute lesion visualization using late gadolinium enhanced magnetic resonance imaging (LGE-MRI) can reliably predict chronic lesion size. Methods Focal lesions were created in left and right ventricles of canine models using either radiofrequency (RF) ablation or cryofocal ablation. Multiple ablation parameters were used. The first LGE-MRI was acquired within 1–5 h post-ablation and the second LGE-MRI was obtained 47–82 days later. Corview software was used to perform lesion segmentations and size calculations. Results: Fifty-Five lesions were created in different locations in the ventricles. Chronic volume size decreased by a mean of 62.5 % (95% CI 58.83–67.97, p < 0.0005). Similar regression of lesion volume was observed regardless of ablation location (p = 0.32), ablation technique (p = 0.94), duration (p = 0.37), power (p = 0.55) and whether lesions were connected or not (p = 0.35). There was no significant difference in lesion volume reduction assessed at 47–54 days and 72–82 days after ablation (p = 0.31). Chronic lesion volume was equal to 0.32 of the acute lesion volumes (R2 = 0.75). Conclusion Chronic tissue injury related to catheter ablation can be reliably modeled as a linear function of the acute lesion volume as assessed by LGE-MRI, regardless of the ablation parameters.
Collapse
|
|
3 |
2 |
21
|
Kreidieh O, Hunter TD, Goyal S, Varley AL, Thorne C, Osorio J, Silverstein J, Varosy P, Metzl M, Leyton-Mange J, Singh D, Rajendra A, Moretta A, Zei PC. Predictors of first pass isolation of the pulmonary veins in real world ablations: An analysis of 2671 patients from the REAL-AF registry. J Cardiovasc Electrophysiol 2024; 35:440-450. [PMID: 38282445 DOI: 10.1111/jce.16190] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 01/08/2024] [Accepted: 01/12/2024] [Indexed: 01/30/2024]
Abstract
INTRODUCTION During atrial fibrillation ablation (AFA), achievement of first pass isolation (FPI) reflects effective lesion formation and predicts long-term freedom from arrhythmia recurrence. We aim to determine the clinical and procedural predictors of pulmonary vein FPI. METHODS We reviewed AFA procedures in a multicenter prospective registry of AFA (REAL-AF). A multivariate ordinal logistic regression, weighted by inverse proceduralist volume, was used to determine predictors of FPI. RESULTS A total of 2671 patients were included with 1806 achieving FPI in both vein sides, 702 achieving FPI in one, and 163 having no FPI. Individually, age, left atrial (LA) scar, higher power usage (50 W), greater posterior contact force, ablation index >350 posteriorly, Vizigo™ sheath utilization, nonstandard ventilation, and high operator volume (>6 monthly cases) were all related to improved odds of FPI. Conversely sleep apnea, elevated body mass index (BMI), diabetes mellitus, LA enlargement, antiarrhythmic drug use, and center's higher fluoroscopy use were related to reduced odds of FPI. Multivariate analysis showed that BMI > 30 (OR 0.78 [0.64-0.96]) and LA volume (OR per mL increase = 1.00 [0.99-1.00]) predicted lower odds of achieving FPI, whereas significant left atrial scarring (>20%) was related to higher rates of FPI. Procedurally, the use of high power (50 W) (OR 1.32 [1.05-1.65]), increasing force posteriorly (OR 2.03 [1.19-3.46]), and nonstandard ventilation (OR 1.26 [1.00-1.59]) predicted higher FPI rates. At a site level, high procedural volume (OR 1.89 [1.48-2.41]) and low fluoroscopy centers (OR 0.72 [0.61-0.84]) had higher rates of FPI. CONCLUSION FPI rates are affected by operator experience, patient comorbidities, and procedural strategies. These factors may be postulated to impact acute lesion formation.
Collapse
|
Review |
1 |
1 |
22
|
van Schie MS, Liao R, Ramdat Misier NL, Knops P, Heida A, Taverne YJHJ, de Groot NMS. Atrial extrasystoles enhance low-voltage fractionation electrograms in patients with atrial fibrillation. Europace 2023; 25:euad223. [PMID: 37477953 PMCID: PMC10401323 DOI: 10.1093/europace/euad223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 07/14/2023] [Indexed: 07/22/2023] Open
Abstract
BACKGROUND AND AIMS Atrial extrasystoles (AES) provoke conduction disorders and may trigger episodes of atrial fibrillation (AF). However, the direction- and rate-dependency of electrophysiological tissue properties on epicardial unipolar electrogram (EGM) morphology is unknown. Therefore, this study examined the impact of spontaneous AES on potential amplitude, -fractionation, -duration, and low-voltage areas (LVAs), and correlated these differences with various degrees of prematurity and aberrancy. METHODS AND RESULTS Intra-operative high-resolution epicardial mapping of the right and left atrium, Bachmann's Bundle, and pulmonary vein area was performed during sinus rhythm (SR) in 287 patients (60 with AF). AES were categorized according to their prematurity index (>25% shortening) and degree of aberrancy (none, mild/opposite, moderate and severe). In total, 837 unique AES (457 premature; 58 mild/opposite, 355 moderate, and 154 severe aberrant) were included. The average prematurity index was 28% [12-45]. Comparing SR and AES, average voltage decreased (-1.1 [-1.2, -0.9] mV, P < 0.001) at all atrial regions, whereas the amount of LVAs and fractionation increased (respectively, +3.4 [2.7, 4.1] % and +3.2 [2.6, 3.7] %, P < 0.001). Only weak or moderate correlations were found between EGM morphology parameters and prematurity indices (R2 < 0.299, P < 0.001). All parameters were, however, most severely affected by either mild/opposite or severely aberrant AES, in which the effect was more pronounced in AF patients. Also, there were considerable regional differences in effects provoked by AES. CONCLUSION Unipolar EGM characteristics during spontaneous AES are mainly directional-dependent and not rate-dependent. AF patients have more direction-dependent conduction disorders, indicating enhanced non-uniform anisotropy that is uncovered by spontaneous AES.
Collapse
|
research-article |
2 |
|
23
|
Chun KRJ, Miklavčič D, Vlachos K, Bordignon S, Scherr D, Jais P, Schmidt B. State-of-the-art pulsed field ablation for cardiac arrhythmias: ongoing evolution and future perspective. Europace 2024; 26:euae134. [PMID: 38848447 PMCID: PMC11160504 DOI: 10.1093/europace/euae134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Accepted: 05/07/2024] [Indexed: 06/09/2024] Open
Abstract
Pulsed field ablation (PFA) is an innovative approach in the field of cardiac electrophysiology aimed at treating cardiac arrhythmias. Unlike traditional catheter ablation energies, which use radiofrequency or cryothermal energy to create lesions in the heart, PFA utilizes pulsed electric fields to induce irreversible electroporation, leading to targeted tissue destruction. This state-of-the-art review summarizes biophysical principles and clinical applications of PFA, highlighting its potential advantages over conventional ablation methods. Clinical data of contemporary PFA devices are discussed, which combine predictable procedural outcomes and a reduced risk of thermal collateral damage. Overall, these technological developments have propelled the rapid evolution of contemporary PFA catheters, with future advancements potentially impacting patient care.
Collapse
|
Review |
1 |
|
24
|
Lee DI, Lee KN, Roh SY, Kim YG, Shim J, Choi JI, Kim YH. Linear Ablation Using a Contact Force-Sensing Catheter in Ablation for Persistent Atrial Fibrillation: A Prospective Randomized Trial. J Clin Med 2024; 13:7310. [PMID: 39685768 DOI: 10.3390/jcm13237310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2024] [Revised: 11/25/2024] [Accepted: 11/28/2024] [Indexed: 12/18/2024] Open
Abstract
Background/Objectives: Pulmonary vein isolation (PVI) using radiofrequency catheter ablation with contact force (CF)-sensing technology has improved long-term outcomes in patients with atrial fibrillation. This prospective randomized study aimed to assess the efficacy and safety of CF-sensing technology for additional left atrial (LA) linear ablation of persistent AF (PerAF). Methods: After PVI, anteromitral (AM) line and roof line ablation were performed using a CF-sensing catheter. Patients were randomly assigned to either the CF-sensing (CFS) group or the CF-blind control (Blind) group. The primary endpoint was atrial arrhythmia recurrence. LA late gadolinium enhancement (LA-LGE) MRI was conducted at baseline and 1-year follow-up for long-term lesion evaluation. Results: A total of 62 patients with drug-refractory PerAF were enrolled (mean age: 58 ± 10 years; 77% male). The success rates of AM and roof line block were 97% and 100% in the CFS group (n = 33) and 93% and 90% in the Blind group (n = 29). The time to achieve block was reduced in the CFS group (AM: 36 ± 22 vs. 48 ± 28 min, p = 0.068; roof: 19 ± 14 vs. 27 ± 15 min, p = 0.031). The maximum CF for safety endpoints was significantly lower in the CFS group (AM: 42 vs. 69 g, p < 0.001; roof: 33 vs. 49 g, p = 0.003). Full linear LA-LGE formation on 1-year MRI did not differ significantly between the groups (AM: 17 vs. 36%; roof; 29 vs. 24%, both p = NS). Kaplan-Meier estimates of AF/AT-free survival after ablation procedures were 63.6% in the CFS group and 58.6% in the Blind group (log-rank p = 0.837). Conclusions: In patients with PerAF, additional LA linear ablation following PVI using CF-sensing technology improved procedural safety and reduced the time needed to achieve conduction block. However, it did not significantly influence clinical outcomes or the formation of permanent full linear lesions.
Collapse
|
|
1 |
|
25
|
Di Biase L, Marazzato J, Gomez T, Byun E, Zou F, Grupposo V, Mohanty S, La Fazia VM, Ammirati G, Lin A, Garcia DY, Della Rocca D, Al Ahamad A, Schiavone M, Gasperetti A, Freilich M, Serna JC, Forleo G, Liu X, Lakkireddy D, Tondo C, Natale A, Zhang XD. Application repetition and electrode-tissue contact result in deeper lesions using a pulsed-field ablation circular variable loop catheter. Europace 2024; 26:euae220. [PMID: 39150065 PMCID: PMC11393494 DOI: 10.1093/europace/euae220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 07/31/2024] [Accepted: 08/12/2024] [Indexed: 08/17/2024] Open
Abstract
AIMS Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter-tissue contact impact lesion formation during PFA. METHODS AND RESULTS A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter-tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). CONCLUSION Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.
Collapse
|
research-article |
1 |
|