Chen GL, Tan Q, Feng YJ, Lan HJ, Yang XW, Zhou XQ. [Determination of 4-methyl-2-pentanol in workplace air by solvent desorption-gas chromatography].
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi 2023;
41:859-862. [PMID:
37935555 DOI:
10.3760/cma.j.cn121094-20230103-000001]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
Objective: To establish a method for the determination of 4-methyl-2-pentanol in the air of workplace by gas chromatography. Methods: In January 2022, 4-methyl-2-pentanol in the air of workplace was collected by activated carbontube, eluted with dichloromethane-methanol (95∶5, V/V), separated by capillary column and determined by gas chromatogram. Results: The limit of detection for 4-methyl-2-pentanol was 0.04 μg/ml. The linear range of 4-methyl-2-pentanol was 0.16-1616.60 μg/ml, with the regression equation of y=1.94x-5.48, and the coefficient correlation was 0.99958, and the minimum detection concentration was 0.03 mg/m(3) (collected sample volume was 1.50 L). The within-run precisions were 1.08%-1.75% and the between-run precisions were 1.41%-2.52%. The desorption rates were 95.15%-99.91%. The samples could be stored at least 3 days at room temperature and 7 days at 4 ℃ without significant loss. Conclusion: The method has the advantages of good precision, high sensitivity and simple operation. It is suitable for the determination of 4-methyl-2-pentanol in the air of workplace.
Collapse