1
|
Pelin G, Sonmez M, Pelin CE. The Use of Additive Manufacturing Techniques in the Development of Polymeric Molds: A Review. Polymers (Basel) 2024; 16:1055. [PMID: 38674976 PMCID: PMC11054453 DOI: 10.3390/polym16081055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 04/03/2024] [Accepted: 04/08/2024] [Indexed: 04/28/2024] Open
Abstract
The continuous growth of additive manufacturing in worldwide industrial and research fields is driven by its main feature which allows the customization of items according to the customers' requirements and limitations. There is an expanding competitiveness in the product development sector as well as applicative research that serves special-use domains. Besides the direct use of additive manufacturing in the production of final products, 3D printing is a viable solution that can help manufacturers and researchers produce their support tooling devices (such as molds and dies) more efficiently, in terms of design complexity and flexibility, timeframe, costs, and material consumption reduction as well as functionality and quality enhancements. The compatibility of the features of 3D printing of molds with the requirements of low-volume production and individual-use customized items development makes this class of techniques extremely attractive to a multitude of areas. This review paper presents a synthesis of the use of 3D-printed polymeric molds in the main applications where molds exhibit a major role, from industrially oriented ones (injection, casting, thermoforming, vacuum forming, composite fabrication) to research or single-use oriented ones (tissue engineering, biomedicine, soft lithography), with an emphasis on the benefits of using 3D-printed polymeric molds, compared to traditional tooling.
Collapse
Affiliation(s)
- George Pelin
- INCAS—National Institute for Aerospace Research “Elie Carafoli”, Bd. Iuliu Maniu 220, 061126 Bucharest, Romania;
| | - Maria Sonmez
- INCDTP-ICPI—National Research and Development Institute for Textile and Leather—Division Leather and Footwear Research Institute, Ion Minulescu St. 93, 031215 Bucharest, Romania;
| | - Cristina-Elisabeta Pelin
- INCAS—National Institute for Aerospace Research “Elie Carafoli”, Bd. Iuliu Maniu 220, 061126 Bucharest, Romania;
| |
Collapse
|
2
|
Casas-Murillo C, Zuñiga-Ruiz A, Lopez-Barron RE, Sanchez-Uresti A, Gogeascoechea-Hernandez A, Muñoz-Maldonado GE, Salinas-Chapa M, Elizondo-Riojas G, Negreros-Osuna AA. 3D-printed anatomical models of the cystic duct and its variants, a low-cost solution for an in-house built simulator for laparoscopic surgery training. Surg Radiol Anat 2021; 43:537-544. [PMID: 33386458 DOI: 10.1007/s00276-020-02631-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 11/17/2020] [Indexed: 02/06/2023]
Abstract
OBJECTIVES To explore a method to create affordable anatomical models of the biliary tree that are adequate for training laparoscopic cholecystectomy with an in-house built simulator. METHODS We used a fused deposition modeling 3D printer to create molds of Acrylonitrile Butadiene Styrene (ABS) from Digital Imaging and Communication on Medicine (DICOM) images, and the molds were filled with silicone rubber. Thirteen surgeons with 4-5-year experience in the procedure evaluated the molds using a low-cost in-house built simulator utilizing a 5-point Likert-type scale. RESULTS Molds produced through this method had a consistent anatomical appearance and overall realism that evaluators agreed or definitely agreed (4.5/5). Evaluators agreed on recommending the mold for resident surgical training. CONCLUSIONS 3D-printed molds created through this method can be applied to create affordable high-quality educational anatomical models of the biliary tree for training laparoscopic cholecystectomy.
Collapse
Affiliation(s)
- C Casas-Murillo
- Radiology and Imaging Department, Facultad de Medicina y Hospital Universitario "Dr. José E. González, Universidad Autónoma de Nuevo León, Ave. Francisco I. Madero S/N, Colonia Mitras Centro, Monterrey, Nuevo León, Mexico
| | - Alejandro Zuñiga-Ruiz
- Department of General Surgery, Facultad de Medicina y Hospital Universitario "Dr. José E. González, Universidad Autónoma de Nuevo León, C.P. 64460, Monterrey, Nuevo León, Mexico
| | - Rafael Eduardo Lopez-Barron
- Centro de Ingeniería Biomédica, Facultad de Medicina, Universidad Autónoma De Nuevo León, Monterrey, Nuevo León, Mexico
| | - Antonio Sanchez-Uresti
- Centro de Ingeniería Biomédica, Facultad de Medicina, Universidad Autónoma De Nuevo León, Monterrey, Nuevo León, Mexico
| | - Andoni Gogeascoechea-Hernandez
- Radiology and Imaging Department, Facultad de Medicina y Hospital Universitario "Dr. José E. González, Universidad Autónoma de Nuevo León, Ave. Francisco I. Madero S/N, Colonia Mitras Centro, Monterrey, Nuevo León, Mexico
| | - Gerardo Enrique Muñoz-Maldonado
- Department of General Surgery, Facultad de Medicina y Hospital Universitario "Dr. José E. González, Universidad Autónoma de Nuevo León, C.P. 64460, Monterrey, Nuevo León, Mexico
| | - Matias Salinas-Chapa
- Radiology and Imaging Department, Facultad de Medicina y Hospital Universitario "Dr. José E. González, Universidad Autónoma de Nuevo León, Ave. Francisco I. Madero S/N, Colonia Mitras Centro, Monterrey, Nuevo León, Mexico
| | - Guillermo Elizondo-Riojas
- Radiology and Imaging Department, Facultad de Medicina y Hospital Universitario "Dr. José E. González, Universidad Autónoma de Nuevo León, Ave. Francisco I. Madero S/N, Colonia Mitras Centro, Monterrey, Nuevo León, Mexico
| | - Adrian A Negreros-Osuna
- Radiology and Imaging Department, Facultad de Medicina y Hospital Universitario "Dr. José E. González, Universidad Autónoma de Nuevo León, Ave. Francisco I. Madero S/N, Colonia Mitras Centro, Monterrey, Nuevo León, Mexico.
| |
Collapse
|
3
|
Wu HH, Priester A, Khoshnoodi P, Zhang Z, Shakeri S, Afshari Mirak S, Asvadi NH, Ahuja P, Sung K, Natarajan S, Sisk A, Reiter R, Raman S, Enzmann D. A system using patient-specific 3D-printed molds to spatially align in vivo MRI with ex vivo MRI and whole-mount histopathology for prostate cancer research. J Magn Reson Imaging 2018; 49:270-279. [PMID: 30069968 DOI: 10.1002/jmri.26189] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Accepted: 04/25/2018] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Patient-specific 3D-printed molds and ex vivo MRI of the resected prostate have been two important strategies to align MRI with whole-mount histopathology (WMHP) for prostate cancer (PCa) research, but the combination of these two strategies has not been systematically evaluated. PURPOSE To develop and evaluate a system that combines patient-specific 3D-printed molds with ex vivo MRI (ExV) to spatially align in vivo MRI (InV), ExV, and WMHP in PCa patients. STUDY TYPE Prospective cohort study. POPULATION Seventeen PCa patients who underwent 3T MRI and robotic-assisted laparoscopic radical prostatectomy (RALP). FIELD STRENGTH/SEQUENCES T2 -weighted turbo spin-echo sequences at 3T. ASSESSMENT Immediately after RALP, the fresh whole prostate specimens were imaged in patient-specific 3D-printed molds by 3T MRI and then sectioned to create WMHP slides. The time required for ExV was measured to assess impact on workflow. InV, ExV, and WMHP images were registered. Spatial alignment was evaluated using: slide offset (mm) between ExV slice locations and WMHP slides; overlap of the 3D prostate contour on InV versus ExV using Dice's coefficient (0 to 1); and 2D target registration error (TRE, mm) between corresponding landmarks on InV, ExV, and WMHP. Data are reported as mean ± standard deviation (SD). STATISTICAL TESTING Differences in 2D TRE before versus after registration were compared using the Wilcoxon signed-rank test (P < 0.05 considered significant). RESULTS ExV (duration 115 ± 15 min) was successfully incorporated into the workflow for all cases. Absolute slide offset was 1.58 ± 1.57 mm. Dice's coefficient was 0.865 ± 0.035. 2D TRE was significantly reduced after registration (P < 0.01) with mean (±SD of per patient means) of 1.9 ± 0.6 mm for InV versus ExV, 1.4 ± 0.5 mm for WMHP versus ExV, and 2.0 ± 0.5 mm for WMHP versus InV. DATA CONCLUSION The proposed system combines patient-specific 3D-printed molds with ExV to achieve spatial alignment between InV, ExV, and WMHP with mean 2D TRE of 1-2 mm. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:270-279.
Collapse
Affiliation(s)
- Holden H Wu
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.,Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA
| | - Alan Priester
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA.,Department of Urology, University of California Los Angeles, Los Angeles, California, USA
| | - Pooria Khoshnoodi
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| | - Zhaohuan Zhang
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.,Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA
| | - Sepideh Shakeri
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| | - Sohrab Afshari Mirak
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| | - Nazanin H Asvadi
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| | - Preeti Ahuja
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| | - Kyunghyun Sung
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.,Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA
| | - Shyam Natarajan
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA.,Department of Urology, University of California Los Angeles, Los Angeles, California, USA
| | - Anthony Sisk
- Department of Pathology, University of California Los Angeles, Los Angeles, California, USA
| | - Robert Reiter
- Department of Urology, University of California Los Angeles, Los Angeles, California, USA
| | - Steven Raman
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.,Department of Urology, University of California Los Angeles, Los Angeles, California, USA
| | - Dieter Enzmann
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| |
Collapse
|