1
|
Remote control of fluid motion in a channel by acoustic holography. ULTRASONICS 2024; 140:107303. [PMID: 38537518 DOI: 10.1016/j.ultras.2024.107303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 03/15/2024] [Accepted: 03/19/2024] [Indexed: 05/04/2024]
Abstract
A new method for manipulating fluid movement using sound waves is presented in this paper. The method relies on acoustic streaming near the free surface of the fluid in a channel with an open top. The sound waves are modulated in phase using acoustic phase holography, which creates a periodic phase pattern from 0 to 2π along a straight path on a target plane. The paper also describes an experimental design to study the main factors influencing the method, such as frequency, number of phase patterns in the path, and sound pressure amplitude. The paper shows that phase pitch and voltage significantly affects fluid speed and that there is a good match between the theoretical and experimental results. Furthermore, the article reports additional experiments with different channel shapes to demonstrate the versatility of the method in controlling fluid motion. The highest fluid speed observed was 0.4 mm/s at a frequency of 1300 kHz and a phase pitch of 5. The paper also investigates the effect of changing the frequency on reversing the flow direction in a U-shaped channel, both experimentally and theoretically. The paper concludes that this method could be a suitable alternative to other acoustic devices for inducing fluid motion because of its simple and flexible design, fabrication, accuracy, and ability to handle complex channels.
Collapse
|
2
|
Advancements in transdermal drug delivery: A comprehensive review of physical penetration enhancement techniques. Int J Pharm 2024; 652:123856. [PMID: 38281692 DOI: 10.1016/j.ijpharm.2024.123856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 01/12/2024] [Accepted: 01/24/2024] [Indexed: 01/30/2024]
Abstract
Transdermal drug administration has grown in popularity in the pharmaceutical research community due to its potential to improve drug bioavailability, compliance among patients, and therapeutic effectiveness. To overcome the substantial barrier posed by the stratum corneum (SC) and promote drug absorption within the skin, various physical penetration augmentation approaches have been devised. This review article delves into popular physical penetration augmentation techniques, which include sonophoresis, iontophoresis, magnetophoresis, thermophoresis, needle-free injection, and microneedles (MNs) Sonophoresis is a technique that uses low-frequency ultrasonic waves to break the skin's barrier characteristics, therefore improving drug transport and distribution. In contrast, iontophoresis uses an applied electric current to push charged molecules of drugs inside the skin, effectively enhancing medication absorption. Magnetophoresis uses magnetic fields to drive drug carriers into the dermis, a technology that has shown promise in aiding targeted medication delivery. Thermophoresis is the regulated heating of the skin in order to improve drug absorption, particularly with thermally sensitive drug carriers. Needle-free injection technologies, such as jet injectors (JIs) and microprojection arrays, offer another option by producing temporary small pore sizes in the skin, facilitating painless and effective drug delivery. MNs are a painless, minimally invasive method, easy to self-administration, as well as high drug bioavailability. This study focuses on the underlying processes, current breakthroughs, and limitations connected with all of these approaches, with an emphasis on their applicability in diverse therapeutic areas. Finally, a thorough knowledge of these physical enhancement approaches and their incorporation into pharmaceutical research has the potential to revolutionize drug delivery, providing more efficient and secure treatment choices for a wide range of health-related diseases.
Collapse
|
3
|
Integrated Rayleigh wave streaming-enhanced sensitivity of shear horizontal surface acoustic wave biosensors. Biosens Bioelectron 2024; 247:115944. [PMID: 38141441 DOI: 10.1016/j.bios.2023.115944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/30/2023] [Accepted: 12/19/2023] [Indexed: 12/25/2023]
Abstract
Shear horizontal surface acoustic wave (SH-SAW) sensors are regarded as a promising alternative for label-free, sensitive, real time and low-cost detection. Nevertheless, achieving high sensitivity with SH-SAW has approached its limit imposed by the mass transport and probe-target affinity. We present here an SH-SAW biosensor accompanied by a unique Rayleigh wave-based actuator. The platform assembled on an ST-quartz substrate consists of dual-channel SH-SAW delay lines fabricated along a 90°-rotated direction, whilst another interdigital electrode (IDT) is orthogonally placed to generate Rayleigh waves so as to induce favourable streaming in the bio-chamber, enhancing the binding efficiency of the bio-target. Theoretical foundation and simulation have shown that Rayleigh acoustic streaming generates a level of agitation that accelerates the mass transport of the biomolecules to the surface. A fourfold improvement in sensitivity is achieved compared with conventional SH-SAW biosensors by means of complementary DNA hybridization with the aid of the Rayleigh wave device, giving a sensitivity level up to 6.15 Hz/(ng/mL) and a limit of detection of 0.617 ng/mL. This suggests that the proposed scheme could improve the sensitivity of SAW biosensors in real-time detection.
Collapse
|
4
|
Magnesium and magnesium alloy dissolution by high intensity focused ultrasound: erosion/cavitation vs. Wave propagation. ULTRASONICS SONOCHEMISTRY 2024; 104:106836. [PMID: 38430906 PMCID: PMC10912864 DOI: 10.1016/j.ultsonch.2024.106836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 02/07/2024] [Accepted: 02/27/2024] [Indexed: 03/05/2024]
Abstract
The dissolution of metals, influenced by mechanical and chemical factors, plays a crucial role in various applications. Ultrasonic irradiation has been explored for its ability to enhance dissolution rates and modify surface characteristics. In this study, we investigate the dissolution of magnesium (Mg) and magnesium alloys under high-intensity focused ultrasound (HIFU) conditions with frequency sweeping (wobbling). Our findings reveal distinct effects of cavitation and acoustic streaming on the dissolution process. For pure magnesium, ultrasonic treatment significantly increases dissolution rates compared to silent conditions. Negative frequency sweeps result in the highest dissolution rates, linked to increased cavitation activity, while positive sweeps reduce dissolution rates but maintain acoustic streaming effects. The removal of surface oxides is accelerated in all sonication conditions. Macro- and micro-roughness patterns on the surface correspond to the wobbling frequency range, with wavelengths matching the average ultrasonic frequency. However, dissolution is not uniform across the sample, and preferential attack occurs at the focal point during negative frequency sweeps. In contrast, magnesium alloys exhibit lower dissolution rates than pure Mg. The alloy's mechanical properties make it less susceptible to cavitation erosion but more sensitive to acoustic streaming-induced dissolution. Grain boundaries are preferentially attacked, revealing differences between ductile pure Mg and the harder, more cavitation-resistant, alloy. This study highlights the complex interplay between cavitation and acoustic streaming in the dissolution of magnesium and its alloys under HIFU conditions, shedding light on the limits and potential applications of this technique, particularly in microstructure analysis.
Collapse
|
5
|
Numerical and experimental investigation on the performance of rapid ultrasonic-assisted nucleic acid extraction based on dispersive two-phase flow. Anal Chim Acta 2024; 1288:342176. [PMID: 38220306 DOI: 10.1016/j.aca.2023.342176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 12/11/2023] [Accepted: 12/21/2023] [Indexed: 01/16/2024]
Abstract
BACKGROUND Nucleic acid extraction (NAE) is an essential step in the whole process of nucleic acid detection (NAT). Traditional manual extraction methods are time-consuming and laborious, unfavorable to the point-of-care testing of nucleic acids. Ultrasound has been emphasized due to its noncontact and easy-to-manipulate characteristics, and integration with microfluidic chip can realize rapid NAE through acoustic streaming effect. The uniformity of magnetic bead mixing in this process is a critical factor affecting the extraction effect. In this study, we developed an ultrasound-assisted NAE technique based on the magnetic bead method and optimized the chip structure to achieve rapid NAE. RESULT We use ultrasonic-assisted coupled with magnetic bead method for ultra-fast NAE. The mixing process of magnetic beads driven by acoustic streaming is simulated by a dispersive two-phase flow model, and the ultrasonic incidence angle (θin), cone structure aspect ratio (Dc/Hc) and sheet structure thickness (Hp) are optimized to enhance the mixing performance. Furthermore, the effectiveness of NAE is validated by utilizing quantitative real-time PCR (qPCR) detection. The findings reveal that a θin value of 10° yields superior mixing performance compared to other incidence angles, resulting in a maximum increase of 84 % in mixing intensity. When Dc/Hc = 0.5 and Hp = 0.5 mm, the maximum mixing index in the localized region of the chamber after 1 s of ultrasound action can reach 83.6 % and 92.5 %, respectively. Compared to the original chamber, the CT values extracted after 5 s of ultrasound action shifted forward by up to 1.9 ct and 4.1 ct, respectively. SIGNIFICANCE The dispersed two-phase flow model can effectively simulate the mixing process of magnetic beads, which plays an important role in assisting the structural design of chip extraction chambers. The single-step mixing of ultrasound-assisted NAE takes only 15s to achieve an extraction performance comparable to manual extraction. The extraction process can be completed within 7 min after integrating this technology with microfluidic chips and automated equipment, providing a solution for automated and efficient NAE.
Collapse
|
6
|
Characterization of the acoustic cavitation in ionic liquids in a horn-type ultrasound reactor. ULTRASONICS SONOCHEMISTRY 2024; 102:106721. [PMID: 38103370 PMCID: PMC10765111 DOI: 10.1016/j.ultsonch.2023.106721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 12/07/2023] [Accepted: 12/08/2023] [Indexed: 12/19/2023]
Abstract
Most ultrasound-based processes root in empirical approaches. Because nearly all advances have been conducted in aqueous systems, there exists a paucity of information on sonoprocessing in other solvents, particularly ionic liquids (ILs). In this work, we modelled an ultrasonic horn-type sonoreactor and investigated the effects of ultrasound power, sonotrode immersion depth, and solvent's thermodynamic properties on acoustic cavitation in nine imidazolium-based and three pyrrolidinium-based ILs. The model accounts for bubbles, acoustic impedance mismatch at interfaces, and treats the ILs as incompressible, Newtonian, and saturated with argon. Following a statistical analysis of the simulation results, we determined that viscosity and ultrasound input power are the most significant variables affecting the intensity of the acoustic pressure field (P), the volume of cavitation zones (V), and the magnitude of the maximum acoustic streaming surface velocity (u). V and u increase with the increase of ultrasound input power and the decrease in viscosity, whereas the magnitude of negative P decreases as ultrasound power and viscosity increase. Probe immersion depth positively correlates with V, but its impact on P and u is insignificant. 1-alkyl-3-methylimidazolium-based ILs yielded the largest V and the fastest acoustic jets - 0.77 cm3 and 24.4 m s-1 for 1-ethyl-3-methylimidazolium chloride at 60 W. 1-methyl-3-(3-sulfopropyl)-imidazolium-based ILs generated the smallest V and lowest u - 0.17 cm3 and 1.7 m s-1 for 1-methyl-3-(3-sulfopropyl)-imidazolium p-toluene sulfonate at 20 W. Sonochemiluminescence experiments validated the model.
Collapse
|
7
|
The effect of microchannel height on the acoustophoretic motion of sub-micron particles. ULTRASONICS 2024; 136:107126. [PMID: 37553269 DOI: 10.1016/j.ultras.2023.107126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 06/19/2023] [Accepted: 07/26/2023] [Indexed: 08/10/2023]
Abstract
Acoustophoresis is an effective technique for particle manipulation. Acoustic radiation force scales with particle volume, enabling size separation. Yet, isolating sub-micron particles remains a challenge due to the acoustic streaming effect (ASE). While some studies confirmed the focusing ability of ASE, others reported continuous stirring effects. To investigate the parameters that influence ASE-induced particle motion in a microchannel, this study examined the effect of microchannel height and particle size. We employed standing surface acoustic wave (SSAW) to manipulate polystyrene particles suspended in the water-filled microchannel. The results show that ASE can direct particles as small as 0.31 µm in diameter to the centre of the streaming vortices, and increasing the channel height enhances the focusing effect. Smaller particles circulate in the streaming vortices continuously, with no movement towards the centres. We also discovered that when the channel height is at least 0.75 the fluid wavelength, particles transitioning from acoustic radiation-dominated to ASE-dominated share the same equilibrium position, which differs from the pressure nodes and the vortices' centres. The spatial distance between particles in different categories can lead to particle separation. Therefore, ASE is a potential alternative mechanism for sub-micron particle sorting when the channel height is accurately adjusted.
Collapse
|
8
|
Regulation of Bacterial Biofilm Formation by Ultrasound: Role of Autoinducer-2 and Finite-Element Analysis of Acoustic Streaming. ULTRASOUND IN MEDICINE & BIOLOGY 2023:S0301-5629(23)00210-7. [PMID: 37438162 DOI: 10.1016/j.ultrasmedbio.2023.06.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 05/18/2023] [Accepted: 06/25/2023] [Indexed: 07/14/2023]
Abstract
OBJECTIVE The formation of bacterial biofilm regulated by quorum sensing (QS) is a critical factor that contributes to infections of indwelling medical devices. Autoinducer-2 (AI-2), as a signal molecule in QS, plays a crucial role in mediating bacterial signaling and regulating their biological behavior. This study investigated the impact of ultrasonic vibration at varying frequencies on biofilm formation in a mixture of Staphylococcus aureus and Escherichia coli. METHODS By exciting ultrasound at different frequencies (20, 100 and 200 kHz), a vibration with an amplitude of 100 nm was generated on the material surface located at the bottom of the petri dish containing mixed bacteria. We measured the content of AI-2 and bacteria in the mixed bacterial solution and bioburden on material surfaces at different time points during culture. In addition, the relationships among AI-2 content, bacterial concentration and distribution were assessed through finite-element analysis of acoustic streaming under ultrasonic vibration. RESULTS The AI-2 gradient is influenced by the diversity of acoustic streaming patterns on the material surface and in the mixed bacterial solution caused by ultrasonic vibration at different frequencies, thereby regulating biofilm formation. The experimental results showed that the optimal inhibition effect on AI-2 and minimal bacterial adhesion degree was achieved when applying an ultrasonic frequency of 100 kHz with a power intensity of 46.1 mW/cm2 under an amplitude of 100 nm. CONCLUSION Ultrasound can affect the QS system of bacteria, leading to alterations in their biological behavior. Different species of bacteria exhibit varying degrees of chemotaxis toward different frequencies.
Collapse
|
9
|
Release of liposomally formulated near-infrared fluorescent probes included in giant cluster vesicles by ultrasound irradiation. ULTRASONICS 2023; 134:107102. [PMID: 37454454 DOI: 10.1016/j.ultras.2023.107102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 07/03/2023] [Accepted: 07/04/2023] [Indexed: 07/18/2023]
Abstract
Detection of tumors and regional lymph nodes during surgery has been proposed in the diagnosis of lymphatic metastasis and the surgical treatment of malignant diseases. Giant cluster vesicles (GCVs), including liposomally formulated indocyanine green (LP-ICG) derivatives, are a possible candidate for agents to realize the two contradictory properties, i.e., retention in tissue for lesion-marking and trace for sentinel lymph nodes (SLNs) identification. We attempted to release the LP-ICG derivatives from GCVs using ultrasound contrast agents (UCAs) under ultrasound irradiation. An absorption spectrophotometer quantitatively evaluated the amounts of released LP-ICG derivatives. As a result, we demonstrated that it depended on conditions for sound pressure, burst length, and number density of UCAs, and had a sound pressure threshold independent of burst length and number density of UCAs. The results will aid to determine appropriate conditions to maximize the released amount of LP-ICG derivatives while keeping safety.
Collapse
|
10
|
Manipulation with sound and vibration: A review on the micromanipulation system based on sub-MHz acoustic waves. ULTRASONICS SONOCHEMISTRY 2023; 96:106441. [PMID: 37216791 PMCID: PMC10213378 DOI: 10.1016/j.ultsonch.2023.106441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/06/2023] [Accepted: 05/12/2023] [Indexed: 05/24/2023]
Abstract
Manipulation of micro-objects have been playing an essential role in biochemical analysis or clinical diagnostics. Among the diverse technologies for micromanipulation, acoustic methods show the advantages of good biocompatibility, wide tunability, a label-free and contactless manner. Thus, acoustic micromanipulations have been widely exploited in micro-analysis systems. In this article, we reviewed the acoustic micromanipulation systems that were actuated by sub-MHz acoustic waves. In contrast to the high-frequency range, the acoustic microsystems operating at sub-MHz acoustic frequency are more accessible, whose acoustic sources are at low cost and even available from daily acoustic devices (e.g. buzzers, speakers, piezoelectric plates). The broad availability, with the addition of the advantages of acoustic micromanipulation, make sub-MHz microsystems promising for a variety of biomedical applications. Here, we review recent progresses in sub-MHz acoustic micromanipulation technologies, focusing on their applications in biomedical fields. These technologies are based on the basic acoustic phenomenon, such as cavitation, acoustic radiation force, and acoustic streaming. And categorized by their applications, we introduce these systems for mixing, pumping and droplet generation, separation and enrichment, patterning, rotation, propulsion and actuation. The diverse applications of these systems hold great promise for a wide range of enhancements in biomedicines and attract increasing interest for further investigation.
Collapse
|
11
|
Degeneration of flow pattern in acousto-elastic flow through sharp-edge microchannels. ULTRASONICS SONOCHEMISTRY 2023; 95:106390. [PMID: 37003213 PMCID: PMC10457586 DOI: 10.1016/j.ultsonch.2023.106390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 03/01/2023] [Accepted: 03/26/2023] [Indexed: 06/19/2023]
Abstract
Acoustic streaming (AS) is the steady time-averaged flow generated by acoustic field, which has been widely used in enhancing mixing and particle manipulation. Current researches on acoustic streaming mainly focus on Newtonian fluids, while many biological and chemical solutions exhibit non-Newtonian properties. The acoustic streaming in viscoelastic fluids has been studied experimentally for the first time in this paper. We found that the addition of polyethylene oxide (PEO) polymer to the Newtonian fluid significantly altered the flow characteristics in the microchannel. The resulting acousto-elastic flow showed two modes: positive mode and negative mode. Specifically, the viscoelastic fluids under acousto-elastic flow exhibit mixing hysteresis features at low flow rates, and degeneration of flow pattern at high flow rates. Through quantitative analysis, the degeneration of flow pattern is further summarized as time fluctuation and spatial disturbance range reduction. The positive mode in acousto-elastic flow can be used for the mixing enhancement of viscoelastic fluids in the micromixer, while the negative mode provides a potential method for particle/cell manipulation in viscoelastic body fluids such as saliva by suppressing unstable flow.
Collapse
|
12
|
A multi-vortex micromixer based on the synergy of acoustics and inertia for nanoparticle synthesis. Anal Chim Acta 2023; 1239:340742. [PMID: 36628735 DOI: 10.1016/j.aca.2022.340742] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 12/21/2022] [Indexed: 12/24/2022]
Abstract
Mixing is one of the most important steps in chemical reaction, sample preparation and emulsification. However, achieving complete mixing of fluids at high throughput is still a challenge for acoustic micromixers, which are limited by the intensity of the acoustic streaming. In this study, we proposed an acoustic-inertial micromixer based on multi-vortex synergy by introducing inertia into acoustic micromixer. The device contains side-wall sharp-edge structure and contraction-expansion array structure (SCEA) in the microchannel to enhance the acoustic streaming with inertial vortices. The mixing mechanism of SCEA was explored and the mixing process showed three modes: acoustic streaming dominant mode, acoustic-inertial synergy mode and inertial vortex dominant mode. On the basis of the "vortex seed" provided by the contraction-expansion structure, stronger chaotic advection was produced by the synergy of acoustic streaming and inertial vortices (including Dean vortex and horizontal vortex). Rapider mixing (0.20 m s) and wider operating ranges (0-3000 μL/min) were achieved in SCEA at lower driving voltages compared with conventional acoustic micromixers. Finally, more homogeneous and tunable chitosan nanoparticles and shellac nanoparticles were synthesized based on this device. The micromorphology, particle size distribution and drug loading properties of the products were measured and compared. This work provides a platform for control of mixing process in specific application environments with high operational flexibility, indicating potentially wider application of SCEA in multi-functional integration of lab-on-a-chip systems.
Collapse
|
13
|
Quantifying cell adhesion through forces generated by acoustic streaming. ULTRASONICS SONOCHEMISTRY 2022; 90:106204. [PMID: 36257212 PMCID: PMC9583098 DOI: 10.1016/j.ultsonch.2022.106204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 09/01/2022] [Accepted: 10/12/2022] [Indexed: 06/16/2023]
Abstract
The strength of cell adhesion is important in understanding the cell's health and in culturing them. Quantitative measurement of cell adhesion strength is a significant challenge in bioengineering research. For this, the present study describes a system that can measure cell adhesion strength using acoustic streaming induced by Lamb waves. Cells are cultured on an ultrasound transducer using a range of preculture and incubation times with phosphate-buffered saline (PBS) just before the measurement. Acoustic streaming is then induced using several Lamb wave intensities, exposing the cells to shear flows and eventually detaching them. By relying upon a median detachment rate of 50 %, the corresponding detachment force, or force of cell adhesion, was determined to be on the order of several nN, consistent with previous reports. The stronger the induced shear flow, the more cells were detached. Further, we employed a preculture time of 8 to 24 h and a PBS incubation time of 0 to 60 min, producing cell adhesion forces that varied from 1.2 to 13 nN. Hence, the developed system can quantify cell adhesion strength over a wide range, possibly offering a fundamental tool for cell-based bioengineering.
Collapse
|
14
|
Patterned Interference Radiation Force for Transcranial Neuromodulation. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:497-511. [PMID: 34955292 DOI: 10.1016/j.ultrasmedbio.2021.11.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 11/06/2021] [Accepted: 11/10/2021] [Indexed: 06/14/2023]
Abstract
Compared with the conventional method of transcranial focused ultrasound stimulation using a single transducer or a focused beam, the compression and tensile forces are generated from the high-pressure gradient of a standing wave that can generate increased stimulation. We experimentally verified a neuromodulation system using patterned interference radiation force (PIRF) and propose a method for obtaining the magnitude of the radiation force, which is considered the main factor influencing ultrasound neuromodulation. The radiation forces generated using a single focused transducer and a standing wave created via two focused transducers were compared using simulations. Radiation force was calculated based on the relationship between the acoustic pressure, radiation force and time-averaged second-order pressure obtained using an acoustic streaming simulation. The presence of the radiation force was verified by measuring the time-averaged second-order pressure generated due to the radiation force, by using a glass tube.
Collapse
|
15
|
Effect of microchannel protrusion on the bulk acoustic wave-induced acoustofluidics: numerical investigation. Biomed Microdevices 2021; 24:7. [PMID: 34964071 DOI: 10.1007/s10544-021-00608-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/11/2021] [Indexed: 11/30/2022]
Abstract
Acoustofluidics inside the microchannel has already found its wide applications recently. Acoustic streaming and radiation force are two underlying mechanisms that determine the trajectory of microparticles and cells in the manipulation. Critical particle size of viscous effects is found to be about 1.6 µm in the conventional rectangular microchannel (W × H = 380 m × 160 m) at the frequency of 2 MHz, below which the acoustic streaming dominants, and is independent of the driving voltage. In order to effectively adjust such a critical size, a approach is proposed and evaluated numerically to enhance the acoustic streaming by adding some protrusions (i.e., in the shape of a wedge, rod, half-ellipse) to the middle of the top or bottom wall. It is found that the resonant frequency and acoustic pressure will decrease and the acoustic streaming velocity will increase significantly, respectively, with the increase of protrusion height (up to 30 µm while keeping the width the same as 8 µm). Subsequently, trajectory motion patterns of microparticles have apparent changes in comparison to those inside the rectangular microchannel, and acoustic streaming can even dominate the motion of large microparticles (i.e., 10 µm). As a result, the critical particle size could be increased up to 72.5 µm. Furthermore, different protrusion shapes (i.e., wedge, rod, half-ellipse) on the top wall were compared. The sharpness of protrusion at its tip seems to determine the acoustic streaming velocity. The wedge attached to the bottom wall had higher resonant frequency and lower acoustic streaming velocity compared with the top wedge in the same dimension. The patterns of acoustic streaming and microparticle trajectory motion in the microchannel with dual wedges on the top and bottom walls are not the superposition of those of the top and bottom wedge individually. In summary, the geometry of the microchannel has a significant effect on the induced acoustofluidics by the bulk acoustic waves. A much larger acoustic streaming velocity is produced at the tip of the protrusion to change the critical size of microparticles between acoustic streaming and radiation force. It suggests that more applications of acoustofluidics (i.e., mixing and sonoporation) to microparticles and cells in various sizes are feasible by designing an appropriate geometry of the microchannel.
Collapse
|
16
|
Suspension culture in a T-flask with acoustic flow induced by ultrasonic irradiation. ULTRASONICS SONOCHEMISTRY 2021; 73:105488. [PMID: 33607592 PMCID: PMC7902488 DOI: 10.1016/j.ultsonch.2021.105488] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 01/11/2021] [Accepted: 02/02/2021] [Indexed: 06/12/2023]
Abstract
Suspension culture is an essential large-scale cell culture technique for biopharmaceutical development and regenerative medicine. To transition from monolayer culture on the culture surface of a flask to suspension culture in a bioreactor, a pre-specified cell number must first be reached. During this period of preparation for suspension culture, static suspension culture in a flask is generally performed because the medium volume is not large enough to use a paddle to circulate the medium. However, drawbacks to this static method include cell sedimentation, leading to high cell density near the bottom and resulting in oxygen and nutrient deficiencies. Here, we propose a suspension culture method with acoustic streaming induced by ultrasonic waves in a T-flask to create a more homogeneous distribution of oxygen, nutrients, and waste products during the preparation period preceding large-scale suspension culture in a bioreactor. To demonstrate the performance of the ultrasonic method, Chinese hamster ovary cells were cultured for 72 h. Results showed that, on average, the cell proliferation was improved by 40% compared with the static method. Thus, the culture time required to achieve a 1000-fold increase could be reduced by 32 h (a 14% reduction) compared with the static method. Furthermore, the ultrasonic irradiation did not compromise the metabolic activity of the cells cultured using the ultrasonic method. These results demonstrate the effectiveness of the ultrasonic method for accelerating the transition to large-scale suspension culture.
Collapse
|
17
|
Characterization of acoustic streaming in water and aluminum melt during ultrasonic irradiation. ULTRASONICS SONOCHEMISTRY 2021; 71:105381. [PMID: 33157358 PMCID: PMC7786621 DOI: 10.1016/j.ultsonch.2020.105381] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 10/20/2020] [Accepted: 10/21/2020] [Indexed: 06/02/2023]
Abstract
It is well known that ultrasonic cavitation causes a steady flow termed acoustic streaming. In the present study, the velocity of acoustic streaming in water and molten aluminum is measured. The method is based on the measurement of oscillation frequency of Karman vortices around a cylinder immersed into liquid. For the case of acoustic streaming in molten metal, such measurements were performed for the first time. Four types of experiments were conducted in the present study: (1) Particle Image Velocimetry (PIV) measurement in a water bath to measure the acoustic streaming velocity visually, (2) frequency measurement of Karman vortices generated around a cylinder in water, and (3) in aluminum melt, and (4) cavitation intensity measurements in molten aluminum. Based on the measurement results (1) and (2), the Strouhal number for acoustic streaming was determined. Then, using the same Strouhal number and measuring oscillation frequency of Karman vortices in aluminum melt, the acoustic streaming velocity was measured. The velocity of acoustic streaming was found to be independent of amplitude of sonotrode tip oscillation both in water and aluminum melt. This can be explained by the effect of acoustic shielding and liquid density.
Collapse
|
18
|
A practical microfluidic pump enabled by acoustofluidics and 3D printing. MICROFLUIDICS AND NANOFLUIDICS 2021; 25:5. [PMID: 33424526 PMCID: PMC7780904 DOI: 10.1007/s10404-020-02411-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Accepted: 12/04/2020] [Indexed: 05/09/2023]
Abstract
Simple and low-cost solutions are becoming extremely important for the evolving necessities of biomedical applications. Even though, on-chip sample processing and analysis has been rapidly developing for a wide range of screening and diagnostic protocols, efficient and reliable fluid manipulation in microfluidic platforms still require further developments to be considered portable and accessible for low-resource settings. In this work, we present an extremely simple microfluidic pumping device based on three-dimensional (3D) printing and acoustofluidics. The fabrication of the device only requires 3D-printed adaptors, rectangular glass capillaries, epoxy and a piezoelectric transducer. The pumping mechanism relies on the flexibility and complexity of the acoustic streaming patterns generated inside the capillary. Characterization of the device yields controllable and continuous flow rates suitable for on-chip sample processing and analysis. Overall, a maximum flow rate of ~ 12 μL/min and the control of pumping direction by frequency tuning is achieved. With its versatility and simplicity, this microfluidic pumping device offers a promising solution for portable, affordable and reliable fluid manipulation for on-chip applications. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s10404-020-02411-w.
Collapse
|
19
|
Enhancing greywater treatment via MHz-Order surface acoustic waves. WATER RESEARCH 2020; 169:115187. [PMID: 31671294 DOI: 10.1016/j.watres.2019.115187] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 10/04/2019] [Accepted: 10/12/2019] [Indexed: 06/10/2023]
Abstract
There is a pressing need for efficient biological treatment systems for the removal of organic compounds in greywater given the rapid increase in household wastewater produced as a consequence of rapid urbanisation. Moreover, proper treatment of greywater allows its reuse that can significantly reduce the demand for freshwater supplies. Herein, we demonstrate the possibility of enhancing the removal efficiency of solid contaminants from greywater using MHz-order surface acoustic waves (SAWs). A key distinction of the use of these high frequency surface acoustic waves, compared to previous work on its lower frequency (kHz order) bulk ultrasound counterpart for wastewater treatment, is the absence of cavitation, which can inflict considerable damage on bacteria, thus limiting the intensity and duration, and hence the efficiency enhancement, associated with the acoustic exposure. In particular, we show that up to fivefold improvement in the removal efficiency can be obtained, primarily due to the ability of the acoustic pressure field in homogenizing and reducing the size of bacterial clusters in the sample, therefore providing a larger surface area that promotes greater bacteria digestion. Alternatively, the SAW exposure allows the reduction in the treatment duration to achieve a given level of removal efficiency, thus facilitating higher treatment rates and hence processing throughput. Given the low-cost of the miniature chipscale platform, these promising results highlight its possibility for portable greywater treatment for domestic use or for large-scale industrial wastewater processing through massive parallelization.
Collapse
|
20
|
Programmable multi-DNA release from multilayered polyelectrolytes using gigahertz nano-electromechanical resonator. J Nanobiotechnology 2019; 17:86. [PMID: 31387581 PMCID: PMC6683436 DOI: 10.1186/s12951-019-0518-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Accepted: 07/30/2019] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Controllable and multiple DNA release is critical in modern gene-based therapies. Current approaches require complex assistant molecules for combined release. To overcome the restrictions on the materials and environment, a novel and versatile DNA release method using a nano-electromechanical (NEMS) hypersonic resonator of gigahertz (GHz) frequency is developed. RESULTS The micro-vortexes excited by ultra-high frequency acoustic wave can generate tunable shear stress at solid-liquid interface, thereby disrupting molecular interactions in immobilized multilayered polyelectrolyte thin films and releasing embedded DNA strands in a controlled fashion. Both finite element model analysis and experiment results verify the feasibility of this method. The release rate and released amount are confirmed to be well tuned. Owing to the different forces generated at different depth of the films, release of two types of DNA molecules with different velocities is achieved, which further explores its application in combined gene therapy. CONCLUSIONS Our research confirmed that this novel platform based on a nano-electromechanical hypersonic resonator works well for controllable single and multi-DNA release. In addition, the unique features of this resonator such as miniaturization and batch manufacturing open its possibility to be developed into a high-throughput, implantable and site targeting DNA release and delivery system.
Collapse
|
21
|
Lamb wave-based molecular diagnosis using DNA hydrogel formation by rolling circle amplification (RCA) process. Biosens Bioelectron 2019; 142:111496. [PMID: 31302395 DOI: 10.1016/j.bios.2019.111496] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 05/10/2019] [Accepted: 07/07/2019] [Indexed: 11/25/2022]
Abstract
Recent developments in microfluidics enable the lab-on-a-chip-based molecular diagnosis. Rapid and accurate diagnosis of infectious diseases is critical for preventing the transmission of the disease. Here, we characterize a Lamb wave-based device using various parameters including the contact angle and viscosity of the sample droplet, the applied voltage, and the temperature increase. Additionally, we demonstrate the functionality of the Lamb wave-based device in clinical application. Optimal temperature for rolling circle amplification (RCA) process is 30 °C, and it was achieved by Lamb wave generation at 17 V. Gene amplification due to RCA process could be detected by viscosity increase due to DNA hydrogel formation in a sample droplet, which induced the acoustic streaming velocity of suspended particles to be decreased. In our Lamb wave-based device, isothermal amplification of target nucleic acids could be successfully detected within 30 min using 10 μL of sessile droplet, and was validated by comparing that of commercial real-time fluorescence analysis. Our device enables simple and low-cost molecular diagnosis, which can be applied to resource-limited clinical settings.
Collapse
|
22
|
Ultrasonic liquid metal processing: The essential role of cavitation bubbles in controlling acoustic streaming. ULTRASONICS SONOCHEMISTRY 2019; 55:243-255. [PMID: 30733147 DOI: 10.1016/j.ultsonch.2019.01.021] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 01/07/2019] [Accepted: 01/17/2019] [Indexed: 05/12/2023]
Abstract
The acoustic streaming behaviour below an ultrasonic sonotrode in water was predicted by numerical simulation and validated by experimental studies. The flow was calculated by solving the transient Reynolds-Averaged Navier-Stokes equations with a source term representing ultrasonic excitation implemented from the predictions of a nonlinear acoustic model. Comparisons with the measured flow field from Particle Image Velocimetry (PIV) water experiments revealed good agreement in both velocity magnitude and direction at two power settings, supporting the validity of the model for acoustic streaming in the presence of cavitating bubbles. Turbulent features measured by PIV were also recovered by the model. The model was then applied to the technologically important area of ultrasonic treatment of liquid aluminium, to achieve the prediction of acoustic streaming for the very first time that accounts for nonlinear pressure propagation in the presence of acoustic cavitation in the melt. Simulations show a strong dependence of the acoustic streaming flow direction on the cavitating bubble volume fraction, reflecting PIV observations. This has implications for the technological use of ultrasound in liquid metal processing.
Collapse
|
23
|
Low-intensity ultrasound induced cavitation and streaming in oxygen-supersaturated water: Role of cavitation bubbles as physical cleaning agents. ULTRASONICS SONOCHEMISTRY 2019; 52:268-279. [PMID: 30573434 DOI: 10.1016/j.ultsonch.2018.11.025] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 11/14/2018] [Accepted: 11/27/2018] [Indexed: 05/27/2023]
Abstract
A number of acoustic and fluid-dynamic phenomena appear in ultrasonic cleaning baths and contribute to physical cleaning of immersed surfaces. Propagation and repeated reflection of ultrasound within cleaning baths build standing-wave-like acoustic fields; when an ultrasound intensity gradient appears in the acoustic fields, it can in principle induce steady streaming flow. When the ultrasound intensity is sufficiently large, cavitation occurs and oscillating cavitation bubbles are either trapped in the acoustic fields or advected in the flow. These phenomena are believed to produce mechanical action to remove contaminant particles attached at material surfaces. Recent studies suggest that the mechanical action of cavitation bubbles is the dominant factor of particle removal in ultrasonic cleaning, but the bubble collapse resulting from high-intensity ultrasound may be violent enough to give rise to surface erosion. In this paper, we aim to carefully examine the role of cavitation bubbles from ultrasonic cleaning tests with varying dissolved gas concentration in water. In our cleaning tests using 28-kHz ultrasound, oxygen-supersaturated water is produced by oxygen-microbubble aeration and used as a cleaning solution, and glass slides spin-coated with silica particles of micron/submicron sizes are used to define cleaning efficiency. High-speed camera recordings and Particle Image Velocimetry analysis with a pressure oscillation amplitude of 1.4 atm at the pressure antinode show that the population of cavitation bubbles increases and streaming flow inside the bath is promoted, as the dissolved oxygen supersaturation increases. The particle removal is found to be achieved mainly by the action of cavitation bubbles, but there exists optimal gas supersaturation to maximize the removal efficiency. Our finding suggests that low-intensity ultrasound irradiation under the optimal gas supersaturation in cleaning solutions allows for having mild bubble dynamics without violent collapse and thus cleaning surfaces without cavitation erosion. Finally, observations of individual bubble dynamics and the resulting particle removal are reported to further support the role of cavitation bubbles as cleaning agents.
Collapse
|
24
|
Fundamental studies of ultrasonic melt processing. ULTRASONICS SONOCHEMISTRY 2019; 52:455-467. [PMID: 30594518 DOI: 10.1016/j.ultsonch.2018.12.028] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Revised: 11/01/2018] [Accepted: 12/14/2018] [Indexed: 05/12/2023]
Abstract
Ultrasonic (cavitation) melt processing attracts considerable interest from both academic and industrial communities as a promising route to provide clean, environment friendly and energy efficient solutions for some of the core issues of the metal casting industry, such as improving melt quality and providing structure refinement. In the last 5 years, the authors undertook an extensive research programme into fundamental mechanisms of cavitation melt processing using state-of-the-art and unique facilities and methodologies. This overview summarises the recent results on the evaluation of acoustic pressure and melt flows in the treated melt, direct observations and quantitative analysis of cavitation in liquid aluminium alloys, in-situ and ex-situ studies of the nucleation, growth and fragmentation of intermetallics, and de-agglomeration of particles. These results provide valuable new insights and knowledge that are essential for upscaling ultrasonic melt processing to industrial level.
Collapse
|
25
|
Acoustic Streaming in a Soft Tissue Microenvironment. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:208-217. [PMID: 30336964 DOI: 10.1016/j.ultrasmedbio.2018.08.026] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 08/28/2018] [Accepted: 08/29/2018] [Indexed: 06/08/2023]
Abstract
We demonstrated that sound can push fluid through a tissue-mimicking material. Although acoustic streaming in tissue has been proposed as a mechanism for biomedical ultrasound applications, such as neuromodulation and enhanced drug penetration, streaming in tissue or acoustic phantoms has not been directly observed. We developed a material that mimics the porous structure of tissue and used a dye and a video camera to track fluid movement. When applied above an acoustic intensity threshold, a continuous focused ultrasound beam (spatial peak time average intensity: 238 W/cm2, centre frequency: 5 MHz) was found to push the dye axially, that is, in the direction of wave propagation and in the radial direction. Dye clearance increased with ultrasound intensity and was modelled using an adapted version of Eckart's acoustic streaming velocity equation. No microstructural changes were observed in the sonicated region when assessed using scanning electron microscopy. Our study indicates that acoustic streaming can occur in soft porous materials and provides a mechanistic basis for future use of streaming for therapeutic or diagnostic purposes.
Collapse
|
26
|
Cavitation and acoustic streaming generated by different sonotrode tips. ULTRASONICS SONOCHEMISTRY 2018; 48:79-87. [PMID: 30080589 DOI: 10.1016/j.ultsonch.2018.05.011] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 05/14/2018] [Accepted: 05/15/2018] [Indexed: 05/07/2023]
Abstract
Aiming at improving the efficiency of cavitation treatment, this work investigates characteristics of acoustic streaming and cavitation generated in water by dumbbell-shaped sonotrodes with plane, truncated and conical tips. The main emphasis was placed on elucidating the effects of tip shape and vibration amplitude ranged from 40 to 60 μm. The PIV technique and Weissler reaction were used to measure flow pattern and velocity of acoustic streaming, and cavitation efficiency, respectively. To provide a theoretical explanation to the experimental results, a self-developed mathematical model was used to simulate the acoustic streaming and predict the size of cavitation zone numerically. Both the experimental and numerical results revealed that the sonotrode tip shape affects the acoustic streaming significantly, altering the flow magnitude and direction from fast and downward under the plane and truncated tips to relatively slow and upward near the conical tip. Besides, the conical tip provides a more efficient cavitation treatment in comparison with the plane and truncated tips. The simulation results showed that widening of cavitation zone and altering of acoustic streaming velocity and direction near the sonotrode tip are responsible for the enhancement of cavitation treatment efficiency.
Collapse
|
27
|
Acoustic streaming induced by two orthogonal ultrasound standing waves in a microfluidic channel. ULTRASONICS 2018; 87:7-19. [PMID: 29428563 DOI: 10.1016/j.ultras.2018.02.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 01/09/2018] [Accepted: 02/03/2018] [Indexed: 06/08/2023]
Abstract
A mathematical model is derived for acoustic streaming in a microfluidic channel confined between a solid wall and a rigid reflector. Acoustic streaming is produced by two orthogonal ultrasound standing waves of the same frequency that are created by two pairs of counter-propagating leaky surface waves induced in the solid wall. The magnitudes and phases of the standing waves are assumed to be different. Full analytical solutions are found for the equations of acoustic streaming. The obtained solutions are used in numerical simulations to reveal the structure of the acoustic streaming. It is shown that the interaction of two standing waves leads to the appearance of a cross term in the equations of acoustic streaming. If the phase lag between the standing waves is nonzero, the cross term brings about circular vortices with rotation axes perpendicular to the solid wall of the channel. The vortices make fluid particles rotate and move alternately up and down between the solid wall and the reflector. The obtained results are of immediate interest for acoustomicrofluidic applications such as the ultrasonic micromixing of fluids and the manipulation of microparticles.
Collapse
|
28
|
Activation of Piezo1 but Not Na V1.2 Channels by Ultrasound at 43 MHz. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1217-1232. [PMID: 29525457 PMCID: PMC5914535 DOI: 10.1016/j.ultrasmedbio.2017.12.020] [Citation(s) in RCA: 86] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Revised: 12/19/2017] [Accepted: 12/22/2017] [Indexed: 05/19/2023]
Abstract
Ultrasound (US) can modulate the electrical activity of the excitable tissues, but the mechanisms underlying this effect are not understood at the molecular level or in terms of the physical modality through which US exerts its effects. Here, we report an experimental system that allows for stable patch-clamp recording in the presence of US at 43 MHz, a frequency known to stimulate neural activity. We describe the effects of US on two ion channels proposed to be involved in the response of excitable cells to US: the mechanosensitive Piezo1 channel and the voltage-gated sodium channel NaV1.2. Our patch-clamp recordings, together with finite-element simulations of acoustic field parameters indicate that Piezo1 channels are activated by continuous wave US at 43 MHz and 50 or 90 W/cm2 through cell membrane stress caused by acoustic streaming. NaV1.2 channels were not affected through this mechanism at these intensities, but their kinetics could be accelerated by US-induced heating.
Collapse
|
29
|
Copper electroplating of PCB interconnects using megasonic acoustic streaming. ULTRASONICS SONOCHEMISTRY 2018; 42:434-444. [PMID: 29429689 DOI: 10.1016/j.ultsonch.2017.12.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 12/03/2017] [Accepted: 12/04/2017] [Indexed: 06/08/2023]
Abstract
In this research experimental and simulated analysis investigates the influence of megasonic (MS; 1 ± 0.05 MHz) acoustic-assisted electroplating techniques, with respect to the fabrication of through-hole via (THV) and blind-via (BV) interconnects for the Printed Circuit Board (PCB) industry. MS plating of copper down THV and BV interconnects was shown to produce measurable benefits such as increased connectivity throughout a PCB and cost savings. More specifically, a 700% increase of copper plating rate was demonstrated for THVs of 175 µm diameter and depth-to-width aspect ratio (ar) of 5.7:1, compared with electrodeposition under no-agitation conditions. For BVs, a 60% average increase in copper thickness deposition in 150 µm and 200 µm, ar 1:1, was demonstrated against plating under standard manufacturing conditions including bubble agitation and panel movement. Finite element modelling simulations of acoustic scattering revealed 1st harmonic influence for plating rate enhancement.
Collapse
|
30
|
Heat transfer enhancement using 2MHz ultrasound. ULTRASONICS SONOCHEMISTRY 2017; 39:262-271. [PMID: 28732945 DOI: 10.1016/j.ultsonch.2017.04.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Revised: 04/14/2017] [Accepted: 04/15/2017] [Indexed: 06/07/2023]
Abstract
The present work focuses on possible heat transfer enhancement from a heating plate towards tap water in forced convection by means of 2MHz ultrasound. The thermal approach allows to observe the increase of local convective heat transfer coefficients in the presence of ultrasound and to deduce a correlation between ultrasound power and Nusselt number. Heat transfer coefficient under ultrasound remains constant while heat transfer coefficient under silent conditions increases with Reynolds number from 900 up to 5000. Therefore, heat transfer enhancement factor ranges from 25% up to 90% for the same energy conditions (supplied ultrasonic power=110W and supplied thermal power=450W). In the same time cavitational activity due to 2MHz ultrasound emission was characterized from mechanical and chemical viewpoints without significant results. At least, Particle Image Velocimetry (PIV) measurements have been performed in order to investigate hydrodynamic modifications due to the presence of 2MHz ultrasound. It was therefore possible to propose a better understanding of heat transfer enhancement mechanism with high frequency ultrasound.
Collapse
|
31
|
Abstract
We demonstrate an acoustic platform for micro-vortexing in disposable polymer microfluidic chips with small-volume (20 μl) reaction chambers. The described method is demonstrated for a variety of standard vortexing functions, including mixing of fluids, re-suspension of a pellet of magnetic beads collected by a magnet placed on the chip, and lysis of cells for DNA extraction. The device is based on a modified Langevin-type ultrasonic transducer with an exponential horn for efficient coupling into the microfluidic chip, which is actuated by a low-cost fixed-frequency electronic driver board. The transducer is optimized by numerical modelling, and different demonstrated vortexing functions are realized by actuating the transducer for varying times; from fractions of a second for fluid mixing, to half a minute for cell lysis and DNA extraction. The platform can be operated during 1 min below physiological temperatures with the help of a PC fan, a Peltier element and an aluminum heat sink acting as the chip holder. As a proof of principle for sample preparation applications, we demonstrate on-chip cell lysis and DNA extraction within 25 s. The method is of interest for automating and chip-integrating sample preparation procedures in various biological assays.
Collapse
|
32
|
Numerical investigation of natural convection heat transfer in a cylindrical enclosure due to ultrasonic vibrations. ULTRASONICS 2017; 76:52-62. [PMID: 28061373 DOI: 10.1016/j.ultras.2016.12.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2016] [Revised: 12/09/2016] [Accepted: 12/12/2016] [Indexed: 06/06/2023]
Abstract
Application of ultrasonic waves for heat transfer augmentation has been proposed in the last few decades. Due to limited researches on acoustic streaming induced by ultrasonic oscillation, the effect of ultrasonic waves on natural convection heat transfer is the main purpose of this paper. At first, natural convection on up-ward-facing heating surface in a cylindrical enclosure filled with air is investigated numerically by the finite difference method, then the effect of upper surface oscillation on convection heat transfer is considered. The conservation equations in Lagrangian approach and compressible fluid are assumed for the numerical simulation. Results show that acoustic pressure will become steady after some milliseconds also pressure oscillation amplitude and acoustic velocity components will be constant therefore steady state velocity is used for solving energy equation. Results show that Enhancement of heat transfer coefficient can be up to 175% by induced ultrasonic waves. In addition, the effect of different parameters on acoustic streaming and heat transfer has been studied.
Collapse
|
33
|
PIV for the characterization of focused field induced acoustic streaming: seeding particle choice evaluation. ULTRASONICS 2017; 76:217-226. [PMID: 28135577 DOI: 10.1016/j.ultras.2017.01.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2016] [Revised: 01/12/2017] [Accepted: 01/12/2017] [Indexed: 06/06/2023]
Abstract
This research evaluates the use of Particle Image Velocimetry (PIV) technique for characterizing acoustic streaming flow generated by High Intensity Focused Ultrasound (HIFU). PIV qualification tests, focusing on the seeding particle size (diameter of 5, 20 and 50μm) were carried out in degassed water subjected to a focused field of 550kHz-frequency with an acoustic pressure amplitude of 5.2, 10.5 and 15.7bar at the focus. This study shows that the ultrasonic field, especially the radiation force, can strongly affect seeding particle behavior. Large particles (50μm-diameter) are repelled from the focal zone and gathered at radiation pressure convergence lines on either side of the focus. The calculation of the acoustic radiation pressure applied on these particles explains the observed phenomenon. PIV measurements do not, therefore, properly characterize the streaming flow in this case. On the contrary, small particles (5μm-diameter) velocity measurements were in good agreement with the Computational Fluid Dynamics (CFD) simulations of the water velocity field. A simple criterion approximating the diameter threshold below which seeding particles are qualified for PIV in presence of focused ultrasound is then proposed.
Collapse
|
34
|
Formation of inverse Chladni patterns in liquids at microscale: roles of acoustic radiation and streaming-induced drag forces. MICROFLUIDICS AND NANOFLUIDICS 2017; 21:50. [PMID: 32226357 PMCID: PMC7089712 DOI: 10.1007/s10404-017-1888-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Accepted: 02/22/2017] [Indexed: 05/23/2023]
Abstract
While Chladni patterns in air over vibrating plates at macroscale have been well studied, inverse Chladni patterns in water at microscale have recently been reported. The underlying physics for the focusing of microparticles on the vibrating interface, however, is still unclear. In this paper, we present a quantitative three-dimensional study on the acoustophoretic motion of microparticles on a clamped vibrating circular plate in contact with water with emphasis on the roles of acoustic radiation and streaming-induced drag forces. The numerical simulations show good comparisons with experimental observations and basic theory. While we provide clear demonstrations of three-dimensional particle size-dependent microparticle trajectories in vibrating plate systems, we show that acoustic radiation forces are crucial for the formation of inverse Chladni patterns in liquids on both out-of-plane and in-plane microparticle movements. For out-of-plane microparticle acoustophoresis, out-of-plane acoustic radiation forces are the main driving force in the near-field, which prevent out-of-plane acoustic streaming vortices from dragging particles away from the vibrating interface. For in-plane acoustophoresis on the vibrating interface, acoustic streaming is not the only mechanism that carries microparticles to the vibrating antinodes forming inverse Chladni patterns: In-plane acoustic radiation forces could have a greater contribution. To facilitate the design of lab-on-a-chip devices for a wide range of applications, the effects of many key parameters, including the plate radius R and thickness h and the fluid viscosity μ, on the microparticle acoustophoresis are discussed, which show that the threshold in-plane and out-of-plane particle sizes balanced from the acoustic radiation and streaming-induced drag forces scale linearly with R and μ , but inversely with h .
Collapse
|
35
|
A viable method to predict acoustic streaming in presence of cavitation. ULTRASONICS SONOCHEMISTRY 2017; 35:518-524. [PMID: 27666196 DOI: 10.1016/j.ultsonch.2016.09.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Revised: 08/29/2016] [Accepted: 09/16/2016] [Indexed: 06/06/2023]
Abstract
The steady liquid flow observed under ultrasonic emitters generating acoustic cavitation can be successfully predicted by a standard turbulent flow calculation. The flow is driven by the classical averaged volumetric force density calculated from the acoustic field, but the inertial term in Navier-Stokes equations must be kept, and a turbulent solution must be sought. The acoustic field must be computed with a realistic model, properly accounting for dissipation by the cavitation bubbles [Louisnard, Ultrason. Sonochem., 19, (2012) 56-65]. Comparison with 20kHz experiments, involving the combination of acoustic streaming and a perpendicular forced flow in a duct, shows reasonably good agreement. Moreover, the persistence of the cavitation effects on the wall facing the emitter, in spite of the deflection of the streaming jet, is correctly reproduced by the model. It is also shown that predictions based either on linear acoustics with the correct turbulent solution, or with Louisnard's model with Eckart-Nyborg's theory yields unrealistic results.
Collapse
|
36
|
Comparing methods for the modelling of boundary-driven streaming in acoustofluidic devices. MICROFLUIDICS AND NANOFLUIDICS 2017; 21:23. [PMID: 32226356 PMCID: PMC7089686 DOI: 10.1007/s10404-017-1865-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Accepted: 01/24/2017] [Indexed: 05/13/2023]
Abstract
Numerical simulations of acoustic streaming flows can be used not only to explain the complex phenomena observed in acoustofluidic manipulation devices, but also to predict and optimise their performances. In this paper, two numerical methods based on perturbation theory are compared in order to demonstrate their viability and applicability for modelling boundary-driven streaming flows in acoustofluidic systems. It was found that the Reynolds stress method, which predicts the streaming fields from their driving terms, can effectively resolve both the inner and outer streaming fields and can be used to demonstrate the driving mechanisms of a broad range of boundary-driven streaming flows. However, computational efficiency typically limits its useful application to two-dimensional models. We highlight the close relationship between the classical boundary-driven streaming vortices and the rotationality of the Reynolds stress force field. The limiting velocity method, which ignores the acoustic boundary layer and solves the outer streaming fields by applying the 'limiting velocities' as boundary conditions, is more computationally efficient and can be used for predicting three-dimensional outer streaming fields and provide insight into their origins, provided that the radius of curvature of the channel surfaces is much greater than the acoustic boundary layer thickness ( δ v ). We also show that for the limiting velocity method to be valid the channel scales must exceed a value of approximately 100 δ v (for an error of ~5% on the streaming velocity magnitudes) for the case presented in this paper. Comparisons of these two numerical methods can provide effective guidance for researchers in the field of acoustofluidics on choosing appropriate methods to predict boundary-driven streaming fields in the design of acoustofluidic particle manipulation devices.
Collapse
|
37
|
Investigation of mass transfer intensification under power ultrasound irradiation using 3D computational simulation: A comparative analysis. ULTRASONICS SONOCHEMISTRY 2017; 34:504-518. [PMID: 27773275 DOI: 10.1016/j.ultsonch.2016.06.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 05/24/2016] [Accepted: 06/20/2016] [Indexed: 06/06/2023]
Abstract
This paper aims at investigating the influence of acoustic streaming induced by low-frequency (24kHz) ultrasound irradiation on mass transfer in a two-phase system. The main objective is to discuss the possible mass transfer improvements under ultrasound irradiation. Three analyses were conducted: i) experimental analysis of mass transfer under ultrasound irradiation; ii) comparative analysis between the results of the ultrasound assisted mass transfer with that obtained from mechanically stirring; and iii) computational analysis of the systems using 3D CFD simulation. In the experimental part, the interactive effects of liquid rheological properties, ultrasound power and superficial gas velocity on mass transfer were investigated in two different sonicators. The results were then compared with that of mechanical stirring. In the computational part, the results were illustrated as a function of acoustic streaming behaviour, fluid flow pattern, gas/liquid volume fraction and turbulence in the two-phase system and finally the mass transfer coefficient was specified. It was found that additional turbulence created by ultrasound played the most important role on intensifying the mass transfer phenomena compared to that in stirred vessel. Furthermore, long residence time which depends on geometrical parameters is another key for mass transfer. The results obtained in the present study would help researchers understand the role of ultrasound as an energy source and acoustic streaming as one of the most important of ultrasound waves on intensifying gas-liquid mass transfer in a two-phase system and can be a breakthrough in the design procedure as no similar studies were found in the existing literature.
Collapse
|
38
|
Numerical simulation of compressible fluid flow in an ultrasonic suction pump. ULTRASONICS 2016; 70:191-198. [PMID: 27183101 DOI: 10.1016/j.ultras.2016.05.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Revised: 05/06/2016] [Accepted: 05/09/2016] [Indexed: 06/05/2023]
Abstract
Characteristics of an ultrasonic suction pump that uses a vibrating piston surface and a pipe are numerically simulated and compared with experimental results. Fluid analysis based on the finite-difference time-domain (FDTD) routine is performed, where the nonlinear term and the moving fluid-surface boundary condition are considered. As a result, the suction mechanism of the pump is found to be similar to that of a check valve, where the gap is open during the inflow phase, and it is nearly closed during the outflow phase. The effects of Reynolds number, vibration amplitude and gap thickness on the pump performance are analyzed. The calculated result is in good agreement with the previously measured results.
Collapse
|
39
|
Y-shaped jets driven by an ultrasonic beam reflecting on a wall. ULTRASONICS 2016; 68:33-42. [PMID: 26907890 DOI: 10.1016/j.ultras.2016.02.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2015] [Revised: 12/29/2015] [Accepted: 02/01/2016] [Indexed: 06/05/2023]
Abstract
This paper presents an original experimental and numerical investigation of acoustic streaming driven by an acoustic beam reflecting on a wall. The water experiment features a 2 MHz acoustic beam totally reflecting on one of the tank glass walls. The velocity field in the plane containing the incident and reflected beam axes is investigated using Particle Image Velocimetry (PIV). It exhibits an original y-shaped structure: the impinging jet driven by the incident beam is continued by a wall jet, and a second jet is driven by the reflected beam, making an angle with the impinging jet. The flow is also numerically modeled as that of an incompressible fluid undergoing a volumetric acoustic force. This is a classical approach, but the complexity of the acoustic field in the reflection zone, however, makes it difficult to derive an exact force field in this area. Several approximations are thus tested; we show that the observed velocity field only weakly depends on the approximation used in this small region. The numerical model results are in good agreement with the experimental results. The spreading of the jets around their impingement points and the creeping of the wall jets along the walls are observed to allow the interaction of the flow with a large wall surface, which can even extend to the corners of the tank; this could be an interesting feature for applications requiring efficient heat and mass transfer at the wall. More fundamentally, the velocity field is shown to have both similarities and differences with the velocity field in a classical centered acoustic streaming jet. In particular its magnitude exhibits a fairly good agreement with a formerly derived scaling law based on the balance of the acoustic forcing with the inertia due to the flow acceleration along the beam axis.
Collapse
|
40
|
Study of the onset of the acoustic streaming in parallel plate resonators with pulse ultrasound. ULTRASONICS 2016; 66:166-171. [PMID: 26705604 DOI: 10.1016/j.ultras.2015.10.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2015] [Revised: 10/19/2015] [Accepted: 10/20/2015] [Indexed: 06/05/2023]
Abstract
In a previous study, we introduced pulse mode ultrasound as a new method for reducing and controlling the acoustic streaming in parallel plate resonators (Hoyos and Castro, 2013). Here, by modifying other parameters such as the resonator geometry and the particle size, we have found a threshold for particle manipulation with ultrasonic standing waves in confined resonators without the influence of the acoustic streaming. We demonstrate that pulse mode ultrasound open the possibility of manipulating particles smaller than 1 μm size.
Collapse
|
41
|
Characterization of HIFU transducers designed for sonochemistry application: Acoustic streaming. ULTRASONICS SONOCHEMISTRY 2016; 29:420-427. [PMID: 26585023 DOI: 10.1016/j.ultsonch.2015.10.019] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2014] [Revised: 10/05/2015] [Accepted: 10/27/2015] [Indexed: 06/05/2023]
Abstract
Cavitation distribution in a High Intensity Focused Ultrasound sonoreactors (HIFU) has been extensively described in the recent literature, including quantification by an optical method (Sonochemiluminescence SCL). The present paper provides complementary measurements through the study of acoustic streaming generated by the same kind of HIFU transducers. To this end, results of mass transfer measurements (electrodiffusional method) were compared to optical method ones (Particle Image Velocimetry). This last one was used in various configurations: with or without an electrode in the acoustic field in order to have the same perturbation of the wave propagation. Results show that the maximum velocity is not located at the focal but shifted near the transducer, and that this shift is greater for high powers. The two cavitation modes (stationary and moving bubbles) are greatly affect the hydrodynamic behavior of our sonoreactors: acoustic streaming and the fluid generated by bubble motion. The results obtained by electrochemical measurements show the same low hydrodynamic activity in the transducer vicinity, the same shift of the active focal toward the transducer, and the same absence of activity in the post-focal axial zone. The comparison with theoretical Eckart's velocities (acoustic streaming in non-cavitating media) confirms a very high activity at the "sonochemical focal", accounted for by wave distortion, which induced greater absorption coefficients. Moreover, the equivalent liquid velocities are one order of magnitude larger than the ones measured by PIV, confirming the enhancement of mass transfer by bubbles oscillation and collapse close to the surface, rather than from a pure streaming effect.
Collapse
|
42
|
Ultrasonic coal washing to leach alkali elements from coals. ULTRASONICS SONOCHEMISTRY 2015; 27:235-240. [PMID: 26186840 DOI: 10.1016/j.ultsonch.2015.05.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Revised: 05/02/2015] [Accepted: 05/13/2015] [Indexed: 06/04/2023]
Abstract
Deposition of fly ash particles onto heat-transfer surfaces is often one of the reasons for unscheduled shut-downs of coal-fired boilers. Fouling deposits encountered in convective sections of a boiler are characterized by arrival of ash particles in solidified (solid) state. Fouling is most frequently caused by condensation and chemical reaction of alkali vapors with the deposited ash particles creating a wet surface conducive to collect impacting ash particles. Hence, the amount of alkali elements present in coals, which, in turn, is available in the flue gas as condensable vapors, determines the formation and growth of fouling deposits. In this context, removal of alkali elements becomes vital when inferior coals having high-ash content are utilized for power generation. With the concept of reducing alkali elements present in a coal entering the combustor, whereby the fouling deposits can either be minimized or be weakened due to absence of alkali gluing effect, the ultrasonic leaching of alkali elements from coals is investigated in this study. Ultrasonic water-washing and chemical-washing, in comparison with agitation, are studied in order to estimate the intensification of the alkali removal process by sonication.
Collapse
|
43
|
Influence of ultrasound power on acoustic streaming and micro-bubbles formations in a low frequency sono-reactor: mathematical and 3D computational simulation. ULTRASONICS SONOCHEMISTRY 2015; 24:193-203. [PMID: 25435397 DOI: 10.1016/j.ultsonch.2014.11.013] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2014] [Revised: 11/10/2014] [Accepted: 11/11/2014] [Indexed: 06/04/2023]
Abstract
This paper aims at investigating the influence of ultrasound power amplitude on liquid behaviour in a low-frequency (24 kHz) sono-reactor. Three types of analysis were employed: (i) mechanical analysis of micro-bubbles formation and their activities/characteristics using mathematical modelling. (ii) Numerical analysis of acoustic streaming, fluid flow pattern, volume fraction of micro-bubbles and turbulence using 3D CFD simulation. (iii) Practical analysis of fluid flow pattern and acoustic streaming under ultrasound irradiation using Particle Image Velocimetry (PIV). In mathematical modelling, a lone micro bubble generated under power ultrasound irradiation was mechanistically analysed. Its characteristics were illustrated as a function of bubble radius, internal temperature and pressure (hot spot conditions) and oscillation (pulsation) velocity. The results showed that ultrasound power significantly affected the conditions of hotspots and bubbles oscillation velocity. From the CFD results, it was observed that the total volume of the micro-bubbles increased by about 4.95% with each 100 W-increase in power amplitude. Furthermore, velocity of acoustic streaming increased from 29 to 119 cm/s as power increased, which was in good agreement with the PIV analysis.
Collapse
|
44
|
Diversity of acoustic streaming in a rectangular acoustofluidic field. ULTRASONICS 2015; 58:27-34. [PMID: 25541360 DOI: 10.1016/j.ultras.2014.11.015] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Revised: 11/24/2014] [Accepted: 11/25/2014] [Indexed: 05/28/2023]
Abstract
Diversity of acoustic streaming field in a 2D rectangular chamber with a traveling wave and using water as the acoustic medium is numerically investigated by the finite element method. It is found that the working frequency, the vibration excitation source length, and the distance and phase difference between two separated symmetric vibration excitation sources can cause the diversity in the acoustic streaming pattern. It is also found that a small object in the acoustic field results in an additional eddy, and affects the eddy size in the acoustic streaming field. In addition, the computation results show that with an increase of the acoustic medium's temperature, the speed of the main acoustic streaming decreases first and then increases, and the angular velocity of the corner eddies increases monotonously, which can be clearly explained by the change of the acoustic dissipation factor and shearing viscosity of the acoustic medium with temperature. Commercialized FEM software COMSOL Multiphysics is used to implement the computation tasks, which makes our method very easy to use. And the computation method is partially verified by an established analytical solution.
Collapse
|
45
|
Acoustic streaming in an ultrasonic air pump with three-dimensional finite-difference time-domain analysis and comparison to the measurement. ULTRASONICS 2014; 54:2119-2125. [PMID: 25001051 DOI: 10.1016/j.ultras.2014.06.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2013] [Revised: 06/17/2014] [Accepted: 06/17/2014] [Indexed: 06/03/2023]
Abstract
The direct finite-difference fluid simulation of acoustic streaming on a fine-meshed three-dimensional model using a graphics processing unit (GPU)-based calculation array is discussed. Airflows are induced by an acoustic traveling wave when an intense sound field is generated in a gap between a bending transducer and a reflector. The calculation results showed good agreement with measurements in a pressure distribution. Several flow vortices were observed near the boundary layer of the reflector and the transducer, which have often been observed near the boundary of acoustic tubes, but have not been observed in previous calculations for this type of ultrasonic air pump.
Collapse
|
46
|
Mechanistic modeling of destratification in cryogenic storage tanks using ultrasonics. ULTRASONICS 2014; 54:76-83. [PMID: 23810463 DOI: 10.1016/j.ultras.2013.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2009] [Revised: 06/12/2012] [Accepted: 05/23/2013] [Indexed: 06/02/2023]
Abstract
Stratification is one of the main causes for vaporization of cryogens and increase of tank pressure during cryogenic storage. This leads subsequent problems such as cavitation in cryo-pumps, reduced length of storage time. Hence, it is vital to prevent stratification to improve the cost efficiency of storage systems. If stratified layers exist inside the tank, they have to be removed by suitable methods without venting the vapor. Sonication is one such method capable of keeping fluid layers mixed. In the present work, a mechanistic model for ultrasonic destratification is proposed and validated with destratification experiments done in water. Then, the same model is used to predict the destratification characteristics of cryogenic liquids such as liquid nitrogen (LN₂), liquid hydrogen (LH₂) and liquid ammonia (LNH₃). The destratification parameters are analysed for different frequencies of ultrasound and storage pressures by considering continuous and pulsed modes of ultrasonic operation. From the results, it is determined that use of high frequency ultrasound (low-power/continuous; high-power/pulsing) or low frequency ultrasound (continuous operation with moderate power) can both be effective in removing stratification.
Collapse
|
47
|
Ultrasound assisted particle and cell manipulation on-chip. Adv Drug Deliv Rev 2013; 65:1600-10. [PMID: 23906935 DOI: 10.1016/j.addr.2013.07.016] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2013] [Revised: 07/15/2013] [Accepted: 07/18/2013] [Indexed: 11/21/2022]
Abstract
Ultrasonic fields are able to exert forces on cells and other micron-scale particles, including microbubbles. The technology is compatible with existing lab-on-chip techniques and is complementary to many alternative manipulation approaches due to its ability to handle many cells simultaneously over extended length scales. This paper provides an overview of the physical principles underlying ultrasonic manipulation, discusses the biological effects relevant to its use with cells, and describes emerging applications that are of interest in the field of drug development and delivery on-chip.
Collapse
|
48
|
Abstract
The purpose of this study was to assess the effect of pulsed amplitude modulated ultrasound (pAMUS) on the level of mineralization in osteoblast cell in comparison to cells stimulated with low-intensity pulsed ultrasound (LIPUS). To make the ultrasound effects more enhanced and targeted at region of interest, this study uses a novel approach of applying pulsed amplitude modulated ultrasound to osteoblast cells. The pAMUS signal was generated using two signal generators. Pulsed signal was amplified through a power amplifier and drove two identical focused ultrasound probes, focusing at the same point in the culture dish. The effects of pAMUS were evaluated using a pAMUS signal of 45 kHz and 100 kHz with 20% duty cycle. The hydrophone verified the formation of a focal point at equal distances (16 mm) from the surface of both transducers. Intensity profile using computer controlled 2D scanner showed circular focal point with a diameter of approximately 10 mm. The effect of the signal was studied using MC3T3-E1 cells cultured in osteogenic medium at time points Day 7, 12 and 18. The cells were analyzed for ALP activity and calcium mineralization. The pAMUS significantly increased the ALP activity and matrix calcification in comparison with LIPUS stimulated cultures.
Collapse
|