1
|
Ten- vs. 14-day antibiotic therapy for culture-positive neonatal sepsis. J Trop Pediatr 2023; 69:fmad036. [PMID: 37986651 DOI: 10.1093/tropej/fmad036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
Abstract
BACKGROUND Neonatal sepsis is a major determinant of neonatal mortality. There is a scarcity of evidence-based guidelines for the duration of antibiotics in culture-positive sepsis. OBJECTIVES The aim of this study was to compare the efficacy of 10- and 14-day antibiotic therapies in the management of culture-positive neonatal sepsis. METHODS This randomized controlled trial was conducted in the neonatal intensive care unit of a tertiary care center among the neonates suffering from culture-positive sepsis (with signs of clinical remission on day 9 of antibiotic) between January 2023 and May 2023. Newborns with major congenital anomaly, deep-seated infections, multi-organ dysfunction, associated fungal infections/infection by multiple organisms and severe birth asphyxia were excluded. Two hundred and thirty-four newborns were randomized into two groups-study (received 10 days of antibiotics) and control (received 14 days of antibiotics). Treatment failure, hospital stay and adverse effects were compared between the two groups. p < 0.05 was taken as the limit of statistical significance. RESULTS Median [interquartile range (IQR)] birth weight and gestational age of the study population (53.8% boys) were 2.424 kg (IQR: 2.183-2.695) and 37.3 weeks (IQR: 35.5-38.1), respectively. Acinetobacter was the most commonly isolated species (56, 23.9%). The baseline characteristics of both groups were almost similar. Treatment failure was similar in the study and control groups (3.8% vs. 1.7%, p = 0.40), with a shorter hospital stay [median (IQR): 14 (13-16) vs. 18 (17-19) days, p < 0.001]. CONCLUSION Ten-day antibiotic therapy was comparable with 14-day antibiotic therapy in efficacy, with a shorter duration of hospital stay and without any significant increase in adverse effects.
Collapse
|
2
|
Growth Performance and Recovery of Nosocomial Aspergillus spp. in Blood Culture Bottles. Microorganisms 2022; 10:microorganisms10102026. [PMID: 36296302 PMCID: PMC9608713 DOI: 10.3390/microorganisms10102026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 10/05/2022] [Accepted: 10/11/2022] [Indexed: 11/21/2022] Open
Abstract
Theoretically, Aspergillus spp. grow in culture media, but frequently, blood cultures of patients with invasive Aspergillosis are negative, even if until now, the reasons are not clear. This aspect underlines the lack of a good strategy for the cultivation and isolation of Aspergillus spp. In order to develop a complete analytical method to detect Aspergillus in clinical and pharmaceutical samples, we investigated the growth performance of two blood culture systems versus the pharmacopeia standard method. At <72 h, all test systems showed comparable sensitivity, about 1−2 conidia. However, the subculture analysis showed a suboptimal recovery for the methods, despite the positive growth and the visualization of the “Aspergillus balls” in the culture media. To investigate this issue, we studied three different subculture approaches: (i) the use of a sterile subculture unit, (ii) the use of a sterile subculture unit and the collection of a larger aliquot (100 µL), following vigorous agitation of the vials, and (iii) to decapsulate the bottle, withdrawing and centrifuging the sample, and aliquot the pellet onto SDA plates. Our results showed that only the third procedure recovered Aspergillus from all positive culture bottles. This work confirmed that our strategy is a valid and faster method to culture and isolate Aspergillus spp. from blood culture bottles.
Collapse
|
3
|
Routine Use of Anaerobic Blood Culture Bottles for Specimens Collected from Adults and Children Enhances Microorganism Recovery and Improves Time to Positivity. J Clin Microbiol 2022; 60:e0050022. [PMID: 36040158 PMCID: PMC9491166 DOI: 10.1128/jcm.00500-22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The utility of anaerobic blood culture bottles remains controversial, especially for specimens from children. Data are limited on the inclusion of an anaerobic bottle as part of a blood culture "set" when using contemporary blood culture instruments and media. Here, we evaluated the clinical utility of anaerobic blood culture bottles (FN Plus) and aerobic bottles (FA Plus) for the BacT/Alert Virtuo blood culture system (bioMérieux). A total of 158,710 bottles collected between November 2018 and October 2019 were evaluated. There were 6,652 positive anaerobic bottles, of which 384 (5.8%) contained 403 obligate anaerobes. In patients <19 years old, there were 389 positive anaerobic bottles, with 15 (1.8%) containing 16 obligate anaerobes. If not for anaerobic bottles, all but 8 obligate anaerobes would have gone undetected. Furthermore, anaerobic bottles were advantageous for some facultative anaerobes. Staphylococcus aureus from anaerobic bottles demonstrated statistically significant increased recovery (1,992 anaerobic versus 1,901 aerobic bottles, P = 0.009) and faster mean time to positivity (1,138 versus 1,174 min, P = 0.027). Only 25 microorganisms had statistically significant improved recovery and/or faster time to positivity from aerobic versus anaerobic bottles, suggesting anaerobic bottles offer comparable growth for most species. Finally, if only an aerobic bottle had been collected, 2,027 fewer positive cultures would have been detected and 7,452 fewer isolates would have been reported, including cultures with S. aureus (413 isolates, 10.6% less), Pseudomonas aeruginosa (9 isolates, 3.1% less) and Escherichia coli (193 isolates, 14.0% less). Taken together, these findings support the practice of routinely including an anaerobic bottle for blood culture collection.
Collapse
|
4
|
Characteristics of False-Positive Alarms in the BacT/Alert 3D System. Microbiol Spectr 2022; 10:e0005522. [PMID: 35467361 PMCID: PMC9241862 DOI: 10.1128/spectrum.00055-22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 04/08/2022] [Indexed: 11/25/2022] Open
Abstract
The BacT/Alert system has been used for detecting the presence of bacteria in various clinical settings as well as in blood services, but it is associated with a relatively high incidence of false-positive results. We analyzed the results of our quality control sterility testing of blood products by BacT/Alert 3D to understand the mechanism of false-positive results. Anaerobic and aerobic bottles were inoculated with 10 mL of samples and cultured in BacT/Alert 3D for 10 days. Positive-reaction cases were classified as true positive if any bacterium was identified or false positive if the identification test had a negative result. The detection algorithm and the bottle graph pattern of the positive reaction cases were investigated. Among the 43,374 samples, 25 true positives (0.06%) and 29 false positives (0.07%) were observed. Although the detection algorithm of all true positives and 25 of 29 false positives was accelerating production of CO2, a steep rise in the bottle graph was observed only in the true positives, and it was not observed in either of the false positives. Four of 29 false positives were dependent on high baseline scatter reflections. Furthermore, evaluating the bottle graph pattern of Streptococcus pneumoniae, a bacterium known to autolyze, we confirmed that no viable bacterium was detected even if a steep rise was observed. In conclusion, the bottle graph pattern of positive reactions allows the differentiation between true positives and false positives. In case of a steep rise without bacterium detection, the bacterium might have autolyzed. Moreover, positive reactions with high baseline scatter reflections, despite immediate loading of bottles after sampling, are potentially false positive. IMPORTANCE In clinical settings, false-positive results are treated as positive until bacterial identification. It may result in the discarding of blood products in blood centers or affect clinical decisions in hospitals or testing facilities. Moreover, the management of these samples is usually time- and labor-consuming. The results of our study may help clinicians and laboratory staff in making a more precise evaluation of positive reactions in BacT/Alert.
Collapse
|
5
|
Comprehensive Study Identifies a Sensitive, Low-Risk, Closed-System Model for Detection of Fungal Contaminants in Cell and Gene Therapy Products. J Clin Microbiol 2021; 59:e0135721. [PMID: 34406794 DOI: 10.1128/jcm.01357-21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The U.S. Food and Drug Administration (FDA) regulates manufacturing and testing of advanced therapeutic medicinal products (ATMPs) to ensure the safety of each product for human use. Gold-standard sterility testing (USP<71>) and alternative blood culture systems have major limitations for the detection of fungal contaminants. In this study, we evaluated the performance of iLYM (lactic acid-fermenting organisms, yeasts, and mold) medium (designed originally for the food and beverage industry) to assess its potential for use in the biopharmaceutical field for ATMP sterility testing. We conducted a parallel evaluation of four different test systems (USP<71>, BacT/Alert, Bactec, and Sabouraud dextrose agar [SDA] culture), three different bottle media formulations (iLYM, iFA Plus, and Myco/F Lytic), and two incubation temperatures (22.5°C and 32.5 to 35°C) using a diverse set of fungi (n = 51) isolated from NIH cleanroom environments and previous product contaminants. Additionally, we evaluated the effect of agitation versus delayed-entry static preincubation on test sensitivity and time to detection (TTD). Overall, delayed entry of bottles onto the BacT/Alert or Bactec instruments (with agitation) did not improve test performance. USP<71> and SDA culture continued to significantly outperform each automated culture condition alone. However, we show, for the first time, that a closed-system, dual-bottle combination of iLYM 22.5°C and iFA Plus 32.5°C can provide high fungal sensitivity, statistically comparable to USP<71>, when tested against a diverse range of environmental fungi. Our study fills a much-needed gap in biopharmaceutical testing and offers a favorable testing algorithm that maximizes bacterial and fungal test sensitivity while minimizing risk of product contamination associated with laboratory handling.
Collapse
|
6
|
Use of 27G needles improves sensitivity and performance of ATCC anaerobe reference microorganism detection in BacT/Alert system. MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT 2021; 20:542-550. [PMID: 33665224 PMCID: PMC7890369 DOI: 10.1016/j.omtm.2021.01.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 01/18/2021] [Indexed: 11/26/2022]
Abstract
Effective detection of microbiological contaminations present in medicinal cellular products is a crucial step to ensure patients' safety. In recent decades, several rapid microbiological methods have been developed and validated, but variabilities linked to the use of different resources have led to discordant validation of methods and performance results. Considering this, while developing an in-house BacT/Alert-based method, we evaluated all of the materials used in its validation. Of particular importance, we noticed that the syringe gauge used to inject the samples into the bottles was crucial to obtain robust results. We chose to conduct a comparative test between the BacT/Alert system and the compendial method described in the European Pharmacopoeia, using five dilutions of nine reference microorganism strains and 21G or 27G needles. Our results confirmed that the BacT/Alert system is a valid and faster alternative method to assess sterility of clinical cell therapy products, and that the use of 27G needles increases its sensitivity to detect reference anaerobe microorganisms.
Collapse
|
7
|
Evaluation of Optimal Blood Culture Incubation Time To Maximize Clinically Relevant Results from a Contemporary Blood Culture Instrument and Media System. J Clin Microbiol 2021; 59:JCM.02459-20. [PMID: 33239377 PMCID: PMC8106720 DOI: 10.1128/jcm.02459-20] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Accepted: 11/23/2020] [Indexed: 12/11/2022] Open
Abstract
Timely diagnosis of microorganisms in blood cultures is necessary to optimize therapy. Although blood culture media and systems have evolved for decades, the standard interval for incubation prior to being discarded as negative has remained 5 days. Here, we evaluated the optimal incubation time for the BacT/Alert Virtuo blood culture detection system (bioMérieux) using FA Plus (aerobic) and FN Plus (anaerobic) resin culture bottles in routine clinical use. Timely diagnosis of microorganisms in blood cultures is necessary to optimize therapy. Although blood culture media and systems have evolved for decades, the standard interval for incubation prior to being discarded as negative has remained 5 days. Here, we evaluated the optimal incubation time for the BacT/Alert Virtuo blood culture detection system (bioMérieux) using FA Plus (aerobic) and FN Plus (anaerobic) resin culture bottles in routine clinical use. Following institutional review board (IRB) approval, a retrospective review evaluated the outcomes of 158,710 bottles collected between November 2018 and October 2019. The number of positive blood bottles was 13,592 (8.6%); 99% of positive aerobic and anaerobic bottles flagged positive by 91.5 and 108 h, respectively. The mean (median) times to positivity were 18.4 h (15.6 h) for Staphylococcus aureus, 12.3 h (9.5 h) for Escherichia coli, 22.2 h (15.9 h) for Pseudomonas aeruginosa, and 48.9 h (42.9 h) for Candida spp. Only 175 bottles (0.1% of all bottles) flagged positive after 4 days of incubation; 89 (51%) of these bottles grew Cutibacterium (Propionibacterium) species. Chart review of blood cultures positive after 4 days (96 h) rarely had a clinical impact and sometimes had a negative impact on patient care. Finally, a seeded study of the HACEK group (i.e., Haemophilus, Aggregatibacter, Cardiobacterium, Eikenella, and Kingella), historically associated with delayed blood culture positivity, demonstrated no benefit to extended incubation beyond 4 days. Collectively, these findings demonstrated that a 4-day incubation time was sufficient for the Virtuo system and media. Implementation of the 4-day incubation time could enhance clinically relevant results by reducing recovery of contaminants and finalizing blood cultures 1 day earlier.
Collapse
|
8
|
Clinical evaluation of FAPlus/FNPlus bottles compared with the combination of SA/SN and FA/FN bottles in the BacT/Alert blood culture system. THE JOURNAL OF MEDICAL INVESTIGATION 2020; 67:90-94. [PMID: 32378625 DOI: 10.2152/jmi.67.90] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Background : The comparison of the performance of FAPlus/FNPlus bottles and combination of SA/SN and FA/FN bottles is not yet reported. Methods : We used human blood samples to investigate microorganism detection rates and the time to positivity (TTP) in a before-vs.-after study (a combination of SA/SN and FA/FN bottles from September 2012 to August 2013 vs. FAPlus/FNPlus bottles from September 2013 to August 2014). Results : The microorganism detection rate was significantly higher in the later period than in the earlier period (11.2% vs. 9.6%, P < 0.001), particularly for Enterococcus and Streptococcus species, nonfermentative Gram-negative bacilli, and Helicobacter cinaedi. TTP for pathogens was longer when FAPlus/FNPlus bottles were used than when a combination of SA/SN and FA/FN bottles was used (14.9 vs. 13.3 h, P = 0.014), particularly, in the case of Gram-negative bacilli including Escherichia coli. Conclusion : The microorganism detection rate was improved with the use of FAPlus/FNPlus bottles compared with the combination of SA/SN and FA/FN bottles ; however, FAPlus/FNPlus bottles seemed to be inferior to SA/SN and FA/FN bottles in terms of TTP. J. Med. Invest. 67 : 90-94, February, 2020.
Collapse
|
9
|
Comparison of the Performance of Three Blood Culture Systems in a Chinese Tertiary-Care Hospital. Front Cell Infect Microbiol 2019; 9:285. [PMID: 31456951 PMCID: PMC6698792 DOI: 10.3389/fcimb.2019.00285] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 07/24/2019] [Indexed: 01/21/2023] Open
Abstract
In this study, we evaluated the performance of three blood culture systems in a Chinese tertiary-care hospital. Samples of simulated bacteremia were prepared using 10 mL of fresh blood from healthy humans and bacterial suspensions of known cell density. Portions of the specimens were treated with an antibiotic or antifungal drug at specified concentrations to simulate antibacterial drug treatment. We analyzed three blood culture systems: BACTEC Plus, BacT/Alert, and VersaTREK. Both time-to-detection (TTD) of 10 types of bacteria and five types of yeasts in samples without antibiotic treatment and positive detection rate of samples treated with different concentrations of antibiotic or antifungal drugs were compared among the culture systems. We also retrospectively analyzed the use of the culture systems in our hospital from 2015 to 2018. In the simulated study, in the absence of antibiotics, the VersaTREK REDOX 1 displayed the shortest TTD for Pseudomonas aeruginosa, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Candida albicans, and Candida glabrata (P < 0.001). Among the anaerobically cultured samples, BACTEC lytic/10 anaerobic/F displayed the shortest TTD for Escherichia coli, S. aureus, Enterococcus faecalis, S. pneumoniae, Bacteroides fragilis, and Bacteroides vulgatus (P < 0.001). Comparatively, BacT/Alert FA/FN showed no advantages. In antibiotic-treated samples, overall recovery rates for the BACTEC, BacT/Alert, and VersaTREK systems were, were 70.2, 43.7, and 27.4%, respectively. BACTEC facilitated higher recovery rate than the other two systems (P < 0.001). In antifungal treatment, the overall recovery rates for the BACTEC, BacT/Alert, and VersaTREK systems were 93.9, 98.3, and 69.4%, respectively. BACTEC Plus showed a recovery rate comparable to that of BacT/Alert (P = 0.835), and the recovery rate of both these systems was higher than that of VersaTREK (P < 0.001). The TTD values and positive rates determined in the retrospective study were consistent with those obtained in the simulated study. The combination of BACTEC PLUS Aerobic/F and BACTEC lytic/10 anaerobic/F culture systems displayed the best clinical performance. Furthermore, the BacT/Alert FAN culture system was found to be more resistant to antifungal drugs and levofloxacin, whereas the VersaTREK system is considered more suitable for primary blood cultures without antibiotic supplementation.
Collapse
|
10
|
Comprehensive Evaluation of Compendial USP<71>, BacT/Alert Dual-T, and Bactec FX for Detection of Product Sterility Testing Contaminants. J Clin Microbiol 2019; 57:JCM.01548-18. [PMID: 30541938 DOI: 10.1128/jcm.01548-18] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Accepted: 11/28/2018] [Indexed: 01/13/2023] Open
Abstract
The emergence of cell therapy programs in large academic centers has led to an increasing demand for clinical laboratories to assist with product sterility testing. Automated blood culture systems have shown promise as alternatives to the manual USP<71> compendial method, but current published data are limited by small organism test sets, particularly for molds. In 2015, failure of the Bactec FX system to detect mold contamination in two products prompted us to evaluate three test systems (compendial USP<71>, Bactec FX, and BacT/Alert Dual-T) over seven different culture combinations, using 118 challenge organisms representative of the NIH current good manufacturing practice (cGMP) environment. At <96 h and <144 h for bacterial and fungal detection, respectively, the compendial USP<71> method significantly outperformed the Bactec FX system (84.7% versus 64.4%; P = 0.0006) but not the BacT/Alert system at 32.5°C (78.8%; P = 0.3116). Extended incubation to 360 h with terminal visual inspection improved sensitivity, without a significant difference between compendial USP<71> and BacT/Alert testing (95.7% versus 89.0%; P = 0.0860); both systems were better than the Bactec FX system (71.2%; P < 0.0001 and P = 0.0003, respectively). The Bactec FX and BacT/Alert systems performed equivalently for 30 isolates derived from clinical bloodstream infections, confirming system optimization for clinical organisms rather than environmental contaminants. Paired Sabouraud dextrose agar (SDA) plates were always positive for fungi within the acceptable time frame. This study shows that the Bactec FX system is suboptimal for product sterility testing, and it provides strong data to support the use of BacT/Alert testing at 32.5°C paired with a supplemental SDA plate as an acceptable alternative to the compendial USP<71> method for product sterility testing.
Collapse
|