1
|
Ventral hernia repair using bioresorbable poly-4-hydroxybutyrate mesh in clean and contaminated surgical fields: a systematic review and meta-analysis. Hernia 2024; 28:575-584. [PMID: 38345668 DOI: 10.1007/s10029-023-02951-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 12/16/2023] [Indexed: 04/06/2024]
Abstract
PURPOSE Use of biologic or synthetic mesh in hernia repair shifts is based on evolving evidence. Poly-4-hydroxybutyrate (P4HB) biosynthetic mesh is a potential alternative to biologic and synthetic mesh in ventral hernia repair (VHR). This meta-analysis assesses the efficacy of P4HB mesh in clean and contaminated surgical settings. METHODS Two authors searched literature on PubMed, reviewing titles and abstracts of all articles to determine inclusion eligibility. Post-operative data were compared via transformation method to convert the proportion of patients with the outcome of interest into a suitable quantity for random-effects synthesis using STATA software. RESULTS Initial search yielded 287 citations. Six studies were included and categorized on whether hernia repairs were conducted in clean (CDC class I) or contaminated cases (CDC class II-IV). The pooled proportion of surgical site infection (SSI), surgical site occurrence (SSO), hernia recurrence, total surgical complications, and reoperation were calculated in 391 clean and 81 contaminated cases. For clean vs. contaminated cases, the following pooled proportions were noted: SSI (2% (CI 0-7%) vs 9% (CI 0-025) (p = 0.03), SSO: 14% (CI 5-25%) vs 35% (CI 22-50%) (p = 0.006), hernia recurrence (8% (CI 1-19%) vs 4% (CI 0-12%) (p = 0.769); surgical complications (17% (CI 6-32%) vs 50% (CI 27-72%) (p = 0.009). Reoperation data were available in 298 clean cases across four studies: 5% (CI 0-15%). CONCLUSIONS P4HB biosynthetic mesh may be more effective than previously thought, particularly in clean wounds. P4HB may also be superior to biologic mesh when compared to clinical trial data. Further research is necessary for more direct comparison.
Collapse
|
2
|
Abstract
A wide array of mesh choices is available for abdominal wall reconstruction, making mesh selection confusing. Understanding mesh properties can make mesh choice simpler. Each mesh has characteristics that determine its durability, ability to clear an infection, and optimal position of placement in the abdominal wall. For clean retromuscular hernia repairs, we prefer bare, heavy weight, permanent synthetic mesh. For contaminated retromuscular abdominal wall reconstruction cases, such as parastomal hernia repairs, we typically use bare, medium weight, permanent synthetic mesh. Biologic and biosynthetic meshes also have acceptable wound event and hernia recurrence rates when used in contaminated cases.
Collapse
|
3
|
Hiatal hernia repair with biosynthetic mesh reinforcement: a qualitative systematic review. Surg Endosc 2023; 37:7425-7436. [PMID: 37721592 DOI: 10.1007/s00464-023-10379-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Accepted: 07/30/2023] [Indexed: 09/19/2023]
Abstract
INTRODUCTION Reinforcement of crural closure with synthetic resorbable mesh has been proposed to decrease recurrence rates after hiatal hernia repair, but continues to be controversial. This systematic review aims to evaluate the safety, efficacy, and intermediate-term results of using biosynthetic mesh to augment the hiatus. METHODS The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed throughout this systematic review. The Risk of Bias in Non-Randomized Studies of Interventions and Risk of Bias in Randomized Trials tools were used to perform qualitative assessment of all studies included in this review. Recommendations were then summarized for the following pre-defined key items: protocol, research question, search strategy, study eligibility, data extraction, study design, risk of bias, publication bias, and statistical analysis. RESULTS The systematic literature search found 520 articles, 101 of which were duplicates and 355 articles were determined to be unrelated to our study and excluded. The full text of the remaining 64 articles was thoroughly assessed. A total of 18 articles (1846 patients) were ultimately included for this review, describing hiatal hernia repair using three different biosynthetic meshes-BIO-A, Phasix ST, and polyglactin mesh. Mean operative time varied from 127 to 223 min. Mean follow up varied from 12 to 54 months. There were no mesh erosions or explants. One mesh-related complication of stenosis requiring reoperation was reported with BIO-A. Studies showed significant improvement in symptom and quality-of-life scores, as well as satisfaction with surgery. Recurrence was reported as radiologic or clinical recurrence. Overall, recurrence rate varied from 0.9 to 25%. CONCLUSION The use of biosynthetic mesh is safe and effective for hiatal hernia repair with low complications rates and high symptom resolution. The reported recurrence rates are highly variable due to significant heterogeneity in defining and evaluating recurrences. Further randomized controlled trials with larger samples and long-term follow-up should be performed to better analyze outcomes and recurrence rates.
Collapse
|
4
|
Transversus abdominis release with biosynthetic mesh for large ventral hernia repair: a 5-year analysis of clinical outcomes and quality of life. Hernia 2023:10.1007/s10029-023-02889-7. [PMID: 37755523 DOI: 10.1007/s10029-023-02889-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 09/10/2023] [Indexed: 09/28/2023]
Abstract
INTRODUCTION Transversus abdominis release (TAR) may provide an optimal plane for mesh placement for large ventral hernias requiring medial myofascial flap advancement. Long-term outcomes of TAR for large ventral hernia repair (VHR) remains under-studied. This study aims to assess longitudinal clinical outcomes and quality of life (QoL) following large VHR with TAR and resorbable biosynthetic mesh. METHODS Retrospective review of clinical outcomes and prospective QoL was performed for patients undergoing VHR with poly-4-hydroxybutyrate mesh and TAR from 2016 to 2021. Patients with ≤ 24 months of follow-up, defects ≤ 150 cm2, and parastomal hernias were excluded. Cost-related data was collected for each patient's hospital course. QoL was compared using paired Wilcoxon signed-rank tests. RESULTS Twenty-nine patients met inclusion criteria. Median age and BMI were 61 years (53.2-68.1 years) and 31.4 kg/m2 (26.1-35.3 kg/m2). Average hernia defect was 390cm2 ± 152.9 cm2. All patients underwent previous abdominal surgery and were primarily Ventral Hernia Working Group 2 (58.6%). Two hernia recurrences (6.9%) occurred over the median follow-up period of 63.1 months (IQR 43.7-71.3 months), with no cases of mesh infection or explantation. Delayed healing and seroma occurred in 27 and 10.3% of patients, respectively. QoL analysis identified a significant improvement in postoperative QoL (p < 0.005), that continued throughout the 5-year follow-up period, with a 41% overall improvement. Cost analysis identified the hospital revenue generated was approximately equal to the direct costs of patient care. Higher costs were associated with ASA class and length of stay (p < 0.05). CONCLUSION Large VHR with resorbable biosynthetic mesh and TAR can be performed safely, with a low recurrence and complication rate, acceptable hospital costs, and significant improvement in disease-specific QoL at long-term follow-up.
Collapse
|
5
|
The utilization of an absorbable mesh after ostomy reversal does not decrease incisional hernia rates. Am J Surg 2023; 226:233-238. [PMID: 37301644 DOI: 10.1016/j.amjsurg.2023.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 04/10/2023] [Accepted: 04/18/2023] [Indexed: 06/12/2023]
Abstract
BACKGROUND Postoperative ostomy reversal hernias are common and can create strain on the healthcare system. There is little literature evaluating the utilization of absorbable mesh following ostomy reversal. The effect on subsequent hernia rates at our institution has not been evaluated. We examine if the addition of absorbable mesh decreases the postoperative hernia rate in our patient population. METHODS We performed a retrospective review of all ileostomy and colostomy reversals. Patients were divided into two groups based on whether an absorbable mesh was used at ostomy closure or not. RESULTS Hernia recurrence rates were lower in the group that had mesh reinforcement (8.96%) vs the group that did not receive a mesh (14.8%) though this was not statistically significant (p = 0.233). CONCLUSION Prophylactic use of an absorbable biosynthetic mesh did not alter the rate of incisional hernia rates following ostomy reversal in our cohort of patients.
Collapse
|
6
|
Comparative long-term effectiveness between ventral hernia repairs with biosynthetic and synthetic mesh. Surg Endosc 2023:10.1007/s00464-023-10082-1. [PMID: 37118030 DOI: 10.1007/s00464-023-10082-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Accepted: 04/17/2023] [Indexed: 04/30/2023]
Abstract
BACKGROUND Debate exists regarding the most appropriate type of mesh to use in ventral hernia repair (VHR). Meshes are broadly categorized as synthetic or biologic, each mesh with individual advantages and disadvantages. More recently developed biosynthetic mesh has characteristics of both mesh types. The current study aims to examine long-term follow-up data and directly compare outcomes-specifically hernia recurrence-of VHR with biosynthetic versus synthetic mesh. METHODS With IRB approval, consecutive cases of VHR (CPT codes 49,560, 49,561, 49,565, and 49,566 with 49,568) performed between 2013 and 2018 at a single institution were reviewed. Local NSQIP data was utilized for patient demographics, perioperative characteristics, CDC Wound Class, comorbidities, and mesh type. A review of electronic medical records provided additional variables including hernia defect size, postoperative wound events to six months, duration of follow-up, and incidence of hernia recurrence. Longevity of repair was measured using Kaplan-Meier method and adjusted Cox proportional hazards regression. RESULTS Biosynthetic mesh was used in 101 patients (23%) and synthetic mesh in 338 (77%). On average, patients repaired using biosynthetic mesh were older than those with synthetic mesh (57 vs. 52 years; p = .008). Also, ASA Class ≥ III was more common in biosynthetic mesh cases (70.3% vs. 55.1%; p = .016). Patients repaired with biosynthetic mesh were more likely than patients with synthetic mesh to have had a prior abdominal infection (30.7% vs. 19.8%; p = .029). Using a Kaplan-Meier analysis, there was not a significant difference in hernia recurrence between the two mesh types, with both types having Kaplan Meir 5-year recurrence-free survival rates of about 72%. CONCLUSION Using Kaplan-Meier analysis, synthetic mesh and biosynthetic mesh result in comparable hernia recurrence rates and surgical site infection rates in abdominal wall reconstruction patients with follow-up to as long as five years.
Collapse
|
7
|
Ventral hernia repair in high-risk patients and contaminated fields using a single mesh: proportional meta-analysis. Hernia 2022; 26:1459-1471. [PMID: 36098869 PMCID: PMC9684228 DOI: 10.1007/s10029-022-02668-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Accepted: 08/25/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE The use of mesh is a common practice in ventral hernia repair (VHR). Lack of consensus on which prosthetic material works better in different settings remains. This meta-analysis aims to summarize the available evidence on hernia recurrence and complications after repair with synthetic, biologic, or biosynthetic/bioabsorbable meshes in hernias grade 2-3 of the Ventral Hernia Working Group modified classification. METHODS A literature search was conducted in January 2021 using Web of Science (WoS), Scopus, and MEDLINE (via PubMed) databases. Randomized Controlled Trials (RCTs) and observational studies with adult patients undergoing VHR with either synthetic, biologic, or biosynthetic/bioabsorbable mesh were included. Outcomes were hernia recurrence, Surgical Site Occurrence (SSO), Surgical Site Infection (SSI), 30 days re-intervention, and infected mesh removal. Random-effects meta-analyses of pooled proportions were performed. Quality of the studies was assessed, and heterogeneity was explored through sensitivity analyses. RESULTS 25 articles were eligible for inclusion. Mean age ranged from 47 to 64 years and participants' follow-up ranged from 1 to 36 months. Biosynthetic/bioabsorbable mesh reported a 9% (95% CI 2-19%) rate of hernia recurrence, lower than synthetic and biologic meshes. Biosynthetic/bioabsorbable mesh repair also showed a lower incidence of SSI, with a 14% (95% CI 6-24%) rate, and there was no evidence of infected mesh removal. Rates of seroma were similar for the different materials. CONCLUSIONS This meta-analysis did not show meaningful differences among materials. However, the best proportions towards lower recurrence and complication rates after grade 2-3 VHR were after using biosynthetic/slowly absorbable mesh reinforcement. These results should be taken with caution, as head-to-head comparative studies between biosynthetic and synthetic/biologic meshes are lacking. Although, biosynthetic/bioabsorbable materials could be considered an alternative to synthetic and biologic mesh reinforcement in these settings.
Collapse
|
8
|
Incisional hernia repair with a slowly absorbable P4HB mesh: what happens after the mesh disappears? A retrospective longitudinal clinical study. Hernia 2022; 27:387-394. [PMID: 35536373 DOI: 10.1007/s10029-022-02616-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 04/09/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE To analyze the incisional hernia recurrence rate at a long-term follow-up using a biosynthetic long-term absorbable mesh in patients with a higher risk of surgical infection in a contaminated surgical field. METHODS This was a retrospective multicentric study. All patients undergoing incisional hernia repair between 2016 and 2018 at 6 participating university centers were included. Patients were classified according to the Ventral Hernia Working Group (VHWG). All consecutive patients who underwent abdominal wall repair using biosynthetic long-term absorbable mesh (Phasix®) in contaminated fields (grade 3 and 4 of the VHWG classification) were included. Patients were followed-up until September 2021. Preoperative, operative, and postoperative data were collected. All patients' surgical site infections (SSIs) and surgical site occurrences (SSOs) were recorded. The primary outcome of interest was the clinical incisional hernia recurrence rate. RESULTS One hundred and eight patients were included: 77 with VHWG grade 3 (71.3%) and 31 with VHWG grade 4 (28.7%). Median time follow-up was 41 months [24; 63]. Twenty-four patients had clinical recurrence during the follow-up (22.2%). The SSI and SSO rates were 24.1% and 36.1%, respectively. On multivariate analysis, risk factors for incisional hernia recurrence were previous recurrence, mesh location, and postoperative enterocutaneous fistula. CONCLUSIONS At the 3 year follow-up, the recurrence rate with a biosynthetic absorbable mesh (Phasix®) for incisional hernia repair in high-risk patients (VHWG grade 3 and 4) seemed to be suitable (22.2%). Most complications occurred in the first year, and SSI and SSO rates were low despite high-risk VHWG grading.
Collapse
|
9
|
Laparoscopic Surgery for Recurrent Hiatal Hernia: Clinical Outcomes and Quality of Life. J Gastrointest Surg 2022; 26:917-920. [PMID: 34668163 DOI: 10.1007/s11605-021-05165-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 09/26/2021] [Indexed: 01/31/2023]
|
10
|
Slowly resorbable biosynthetic mesh: 2-year results in VHWG grade 3 hernia repair. Hernia 2021; 26:131-138. [PMID: 34282506 PMCID: PMC8881263 DOI: 10.1007/s10029-021-02453-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 06/27/2021] [Indexed: 11/05/2022]
Abstract
Introduction Information on the long-term performance of biosynthetic meshes is scarce. This study analyses the performance of biosynthetic mesh (Phasix™) over 24 months. Methods A prospective, international European multi-center trial is described. Adult patients with a Ventral Hernia Working Group (VHWG) grade 3 incisional hernia larger than 10 cm2, scheduled for elective repair, were included. Biosynthetic mesh was placed in sublay position. Short-term outcomes included 3-month surgical site occurrences (SSO), and long-term outcomes comprised hernia recurrence, reoperation, and quality of life assessments until 24 months. Results Eighty-four patients were treated with biosynthetic mesh. Twenty-two patients (26.2%) developed 34 SSOs, of which 32 occurred within 3 months (primary endpoint). Eight patients (11.0%) developed a hernia recurrence. In 13 patients (15.5%), 14 reoperations took place, of which 6 were performed for hernia recurrence (42.9%), 3 for mesh infection (21.4%), and in 7 of which the mesh was explanted (50%). Compared to baseline, quality of life outcomes showed no significant difference after 24 months. Despite theoretical resorption, 10.7% of patients reported presence of mesh sensation in daily life 24 months after surgery. Conclusion After 2 years of follow-up, hernia repair with biosynthetic mesh shows manageable SSO rates and favorable recurrence rates in VHWG grade 3 patients. No statistically significant improvement in quality of life or reduction of pain was observed. Few patients report lasting presence of mesh sensation. Results of biosynthetic mesh after longer periods of follow-up on recurrences and remodeling will provide further valuable information to make clear recommendations. Trial registration Registered on clinicaltrials.gov (NCT02720042), March 25, 2016.
Collapse
|
11
|
Outcomes of biosynthetic absorbable mesh use in high risk CDC Class I ventral hernia repair: a single surgeon series. Hernia 2021; 26:97-108. [PMID: 34105003 DOI: 10.1007/s10029-021-02424-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 04/30/2021] [Indexed: 12/01/2022]
Abstract
PURPOSE Biosynthetic absorbable meshes have emerged as suitable alternatives to permanent synthetic and biologic meshes in complex ventral hernia repair in contaminated wounds. Evidence regarding the use of these products in clean wounds is currently scant. This paper presents a large single surgeon series using GORE®BIO-A® (W.L. Gore & Associates, Newark, DE) (Bio-A) tissue reinforcement in high risk patients with predominantly CDC Class I wounds. METHODS Retrospective review of a prospectively maintained database of consecutive patients who underwent open ventral hernia repair with biosynthetic absorbable mesh was conducted. Ventral Hernia Working Group (VHWG) classification based on patient demographics and Centers for Disease Control (CDC) wound type were collected prospectively. All patients were followed up for a minimum of 12 months post-operatively. RESULTS 155 patients were included with a mean post-operative follow up of 29 months (range 12-62 months). Mean age was 61.8 years with an average BMI of 33.5 kg/m2. 147 patients (94.9%) were classified as VHWG 2 or 3 based on comorbidities or surgical field contamination. 69% (n = 107) of wounds were designated CDC Class I. Mean hernia size was 119.7cm2 with recurrent defects comprising 32.3% (n = 50). Retrorectus mesh repair was achieved in 84.5% of patients (n = 131). Post-operative wound events occurred in 19.3%. No mesh was explanted. Hernia recurrence rate was 9.0% with a mean time to recurrence of 14 months. There was no significant difference in recurrence rates between clean and contaminated wounds. CONCLUSION This study supports the use of Bio-A in high risk ventral hernias, demonstrating a safe and durable repair across all wound classes. Ongoing follow-up continues to monitor for late complications and recurrence.
Collapse
|
12
|
Outcomes of mid-term and long-term degradable biosynthetic meshes in single-stage open complex abdominal wall reconstruction. Hernia 2021; 25:1647-1657. [PMID: 34097187 PMCID: PMC8182350 DOI: 10.1007/s10029-021-02415-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 04/12/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To assess clinical outcomes in patients that underwent open single-stage complex abdominal wall reconstruction (CAWR) with biosynthetic mesh. METHODS Retrospective observational study of two prospectively registered series of consecutive patients undergoing CAWR with either long-term degradable (LTD) Phasix™ or mid-term degradable (MTD) BIO-A® biosynthetic mesh in a single institution between June 2016 and December 2019. RESULTS From 169 patients with CAWR, 70 consecutive patients were identified who underwent CAWR with either LTD or MTD biosynthetic mesh. More than 85% of patients had an incisional hernia that could be classified as moderately complex to major complex due to a previous wound infection (67%), one or more complicating comorbidities (87.1%), one or more complicating hernia characteristics (75.7%) or contaminated or dirty defects (37.1%). Concomitant component separation was performed in 43 of 70 patients (61.4%). Overall surgical site infection (SSI) rate in these CAWR patients was 45.7%. Seventeen of 70 patients (24.3%) had computed tomography (CT) - and culture-confirmed SSI in direct contact of mesh, suspicious of mesh infection. Mesh removal for persistent local infection occurred in 10% (7 of 70) after a median of 229 days since surgery. Salvage rate of mesh after direct contact with infection was 58.8%. All removed meshes were in the LTD group. Seven patients (10%) had a recurrence; four patients in the LTD group (10%) had a recurrence at a median follow-up of 35 months and three patients in the MTD group (10%) at a median follow-up of 11 months. Three of the seven recurrences occurred in patients with SSI in persistent and direct contact with mesh. CONCLUSIONS Comorbid patients undergoing open complex abdominal wall reconstruction are at high risk of postoperative wound complications regardless of which type of biosynthetic mesh is used. When in persistent and direct contact with infection, long-term biodegradable biosynthetic meshes may need to be removed, whereas mid-term biodegradable biosynthetic meshes can be salvaged.
Collapse
|
13
|
Bioabsorbable mesh use in midline abdominal wall prophylaxis and repair achieving fascial closure: a cross-sectional review of stage of innovation. Hernia 2021; 25:3-12. [PMID: 32449096 PMCID: PMC7867504 DOI: 10.1007/s10029-020-02217-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2020] [Accepted: 05/11/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND Achieving stable closure of complex or contaminated abdominal wall incisions remains challenging. This study aimed to characterise the stage of innovation for bioabsorbable mesh devices used during both midline closure prophylaxis and complex abdominal wall reconstruction and to evaluate the quality of current evidence. METHODS A systematic review of published and ongoing studies was performed until 31st December 2019. Inclusion criteria were studies where bioabsorbable mesh was used to support fascial closure either prophylactically after midline laparotomy or for repair of incisional hernia with midline incision. Exclusion criteria were: (1) study design was a systematic review, meta-analysis, letter, review, comment, or conference abstract; (2) included less than p patients; (3) only evaluated biological, synthetic or composite meshes. The primary outcome measure was the IDEAL framework stage of innovation. The key secondary outcome measure was the risk of bias in non-randomised studies of interventions (ROBINS-I) criteria for study quality. RESULTS Twelve studies including 1287 patients were included. Three studies considered mesh prophylaxis and nine studies considered hernia repair. There were only two published studies of IDEAL 2B. The remainder was IDEAL 2A studies. The quality of the evidence was categorised as having a risk of bias of a moderate, serious or critical level in nine of the twelve included studies using the ROBINS-I tool. CONCLUSION The evidence base for bioabsorbable mesh is limited. Better reporting and quality control of surgical techniques are needed. Although new trial results over the next decade will improve the evidence base, more trials in emergency and contaminated settings are required to establish the limits of indication.
Collapse
|
14
|
Slowly absorbable mesh in contaminated incisional hernia repair: results of a French multicenter study. Hernia 2021; 25:1051-1059. [PMID: 33492554 DOI: 10.1007/s10029-020-02366-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Accepted: 12/29/2020] [Indexed: 11/24/2022]
Abstract
PURPOSE To analyze the postoperative morbidity and 1-year recurrence rate of incisional hernia repair using a biosynthetic long-term absorbable mesh in patients at higher risk of surgical infection in a contaminated surgical field. METHODS All patients undergoing incisional hernia repair in a contaminated surgical field with the use of a biosynthetic long-term absorbable mesh (Phasix®) between May 2016 and September 2018 at six participating university centers were included in this retrospective cohort and were followed-up until September 2019. Regarding the risk of surgical infection, patients were classified according to the modified Ventral Hernia Working Group classification. Preoperative, operative and postoperative data were collected. All patients' surgical site infections (SSIs) and occurrences (SSOs) and recurrence rates were the endpoints of the study. RESULTS Two hundred and fifteen patients were included: 170 with mVHWG grade 3 (79%) and 45 with mVHWG grade 2 (21%). The SSI and SSO rates at 12 months were 22.3% and 39.5%, respectively. According to the Dindo-Clavien classification, 43 patients (20.0%) had at least one minor complication, and 57 patients (26.5%) had at least one major complication. Among the 121 patients (56.3%) having at least 1 year of follow-up, the clinical recurrence rate was 12.4%. Multivariate analysis showed that a concomitant gastrointestinal procedure was an independent risk factor for surgical infection (OR = 2.61), and an emergency setting was an independent risk factor for major complications (OR = 11.9). CONCLUSION The use of a biosynthetic absorbable mesh (Phasix®) is safe in a contaminated surgical field, with satisfying immediate postoperative and 1-year results. TRIAL REGISTRATION The study is registered on Clinical Trial ID: NCT04132986.
Collapse
|
15
|
What results can be expected one year after complex incisional hernia repair with biosynthetic mesh? J Visc Surg 2021; 158:111-117. [PMID: 33454303 DOI: 10.1016/j.jviscsurg.2020.07.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND Incisional hernia is a frequent complication after midline laparotomy. The current standard repair includes the use of a synthetic mesh to prevent recurrence. However, the use of a synthetic mesh in a contaminated field carries a higher risk of mesh infection. In this setting biologic and biosynthetic meshes can be used as they resist to infection, but these are absorbable meshes. This raises the question of the risk of recurrence as the mesh disappears. Phasix® is a biosynthetic mesh getting absorbed in 12-18 months. The aim of this study was to assess the 1-year recurrence rate after abdominal-wall repair with a Phasix® mesh. METHODS All patients undergoing ventral hernia repair between 2016 and 2018 at the University Hospital of Dijon using a Phasix® mesh were prospectively included in a database. They were all followed-up with a physical exam and a routine CT scan at one year. All postoperative complications were recorded. RESULTS Twenty-nine patients were included in the study (55.2% women), with a mean BMI of 30,25 kg/m2. Nineteen meshes were sublay and 10 intraperitoneal. Complications at 1 month were mainly mild: Clavien-Dindo I and II (61.1%). No mesh was explanted. There was no chronic infection. The mean length of stay was 11.5 days. The 1-year recurrence rate was 10.3%. CONCLUSION Patients having undergone complex ventral hernia repair with a Phasix® mesh have a 1-year recurrence rate of 10.3%. No severe surgical site occurrence was detected. A longer follow-up in a larger number of patients could confirm the place of this mesh in abdominal-wall repair.
Collapse
|
16
|
Outcomes of a new slowly resorbable biosynthetic mesh (Phasix™) in potentially contaminated incisional hernias: A prospective, multi-center, single-arm trial. Int J Surg 2020; 83:31-36. [PMID: 32931978 DOI: 10.1016/j.ijsu.2020.08.053] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 08/21/2020] [Accepted: 08/26/2020] [Indexed: 01/03/2023]
Abstract
BACKGROUND Resorbable biomaterials have been developed to reduce the amount of foreign material remaining in the body after hernia repair over the long-term. However, on the short-term, these resorbable materials should render acceptable results with regard to complications, infections, and reoperations to be considered for repair. Additionally, the rate of resorption should not be any faster than collagen deposition and maturation; leading to early hernia recurrence. Therefore, the objective of this study was to collect data on the short-term performance of a new resorbable biosynthetic mesh (Phasix™) in patients requiring Ventral Hernia Working Group (VHWG) Grade 3 midline incisional hernia repair. MATERIALS AND METHODS A prospective, multi-center, single-arm trial was conducted at surgical departments in 15 hospitals across Europe. Patients aged ≥18, scheduled to undergo elective Ventral Hernia Working Group Grade 3 hernia repair of a hernia larger than 10 cm2 were included. Hernia repair was performed with Phasix™ Mesh in sublay position when achievable. The primary outcome was the rate of surgical site occurrence (SSO), including infections, that required intervention until 3 months after repair. RESULTS In total, 84 patients were treated with Phasix™ Mesh. Twenty-two patients (26.2%) developed 32 surgical site occurrences. These included 11 surgical site infections, 9 wound dehiscences, 7 seromas, 2 hematomas, 2 skin necroses, and 1 fistula. No significant differences in surgical site occurrence development were found between groups repaired with or without component separation technique, and between clean-contaminated or contaminated wound sites. At three months, there were no hernia recurrences. CONCLUSION Phasix™ Mesh demonstrated acceptable postoperative surgical site occurrence rates in patients with a Ventral Hernia Working Group Grade 3 hernia. Longer follow-up is needed to evaluate the recurrence rate and the effects on quality of life. This study is ongoing through 24 months of follow-up.
Collapse
|
17
|
The use of biosynthetic mesh in giant hiatal hernia repair: is there a rationale? A 3-year single-center experience. Hernia 2020; 25:1355-1361. [PMID: 32712835 DOI: 10.1007/s10029-020-02273-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 07/17/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE Reinforced prosthetic crural repair is particularly indicated for giant hiatal hernias. The rationale is to reduce the recurrence rate in the long term. The aim of our study is to evaluate the outcomes of laparoscopic giant hiatal hernia repair using a biosynthetic mesh. METHODS We retrospectively analyzed 44 patients who underwent laparoscopic mesh-reinforced hiatal closure and fundoplication using a biosynthetic material. Inclusion criterion was large hiatal defects (> 5 cm). Follow-up was scheduled at 6, 12 and 36 months after surgery. RESULTS 44 patients (29F) with a mean age of 62 years (range 14-85) and mean of BMI 24.5 kg/m2 (range 21-29) underwent successful laparoscopic repair. Twenty-six (59.1%) patients had Nissen-Rossetti fundoplication, whereas 18 (40.9%) had Toupet fundoplication. Six-month questionnaire for the evaluation of symptoms was available for 43 patients (97.7%) and for 40 (90.9%) patients at 12 and 36 months. Mean preoperative symptoms score analysis was 1.68 ± 0.73. Mean scores at each follow-up time were significantly improved compared to baseline (p > 0.05). Barium swallow was available in 37 patients (84.1%) at 1 year after surgery. Radiologic recurrence was observed in two patients (4.5%). No patient had symptoms attributable to recurrence or required revisional surgery. There were no mesh-related complications at 3 years follow-up. CONCLUSIONS The use of biosynthetic mesh for crural reinforcement is associated with a low incidence of mesh-related complications and with a reasonably low recurrence rate (4.5%) at 36 months. However, additional data with longer follow-up are needed to determine long-term safety and efficacy.
Collapse
|
18
|
Laparoscopic repair of a giant hiatal hernia after minimally invasive oesophagectomy. Ann R Coll Surg Engl 2020; 102:e130-e132. [PMID: 32326737 DOI: 10.1308/rcsann.2020.0049] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Minimally invasive oesophagectomy has become popular, but studies showed a higher rate of postoperative hiatus hernia compared with open oesophagectomy. Our video presents the laparoscopic biosynthetic mesh repair of a symptomatic giant hiatus hernia in a 71-year-old man who had undergone minimally invasive oesophagectomy one year earlier for distal adenocarcinoma of the oesophagus. The operative time was 120 minutes. The patient started oral intake on postoperative day one and was discharged on postoperative day three. Postoperative computed tomography at six months showed no signs of recurrence. In the setting of a symptomatic hiatus hernia post-minimally invasive oesophagectomy, we suggest an initial laparoscopic approach, because of its countless advantages.
Collapse
|
19
|
A post-market, prospective, multi-center, single-arm clinical investigation of Phasix™ mesh for VHWG grade 3 midline incisional hernia repair: a research protocol. BMC Surg 2018; 18:104. [PMID: 30458747 PMCID: PMC6247668 DOI: 10.1186/s12893-018-0439-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 11/07/2018] [Indexed: 02/05/2023] Open
Abstract
Background Incisional heia is a frequent complication of midline laparotomy. The use of mesh in hernia repair has been reported to lead to fewer recurrences compared to primary repair. However, in Ventral Hernia Working Group (VHWG) Grade 3 hernia patients, whose hernia is potentially contaminated, synthetic mesh is prone to infection. There is a strong preference for resorbable biological mesh in contaminated fields, since it is more able to resist infection, and because it is fully resorbed, the chance of a foreign body reaction is reduced. However, when not crosslinked, biological resorbable mesh products tend to degrade too quickly to facilitate native cellular ingrowth. Phasix™ Mesh is a biosynthetic mesh with both the biocompatibility and resorbability of a biological mesh and the mechanical strength of a synthetic mesh. This multi-center single-arm study aims to collect data on safety and performance of Phasix™ Mesh in Grade 3 hernia patients. Methods A total of 85 VHWG Grade 3 hernia patients will be treated with Phasix™ Mesh in 15 sites across Europe. The primary outcome is Surgical Site Occurrence (SSO) including hematoma, seroma, infection, dehiscence and fistula formation (requiring intervention) through 3 months. Secondary outcomes include recurrence, infection and quality of life related outcomes after 24 months. Follow-up visits will be at drain removal (if drains were not placed, then on discharge or staple removal instead) and in the 1st, 3rd, 6th, 12th, 18th and 24th month after surgery. Conclusion Based on evidence from this clinical study Depending on the results this clinical study will yield, Phasix™ Mesh may become a preferred treatment option in VHWG Grade 3 patients. Trial registration The trial was registered on March 25, 2016 on clinicaltrials.gov: NCT02720042.
Collapse
|
20
|
Abstract
Prior publications of the Surgical Clinics of North America have highlighted the technical challenges of abdominal wall reconstruction. This article provides an update on synthetic, biologic, and biosynthetic mesh research since the 2013 Surgical Clinics of North America hernia publication and highlights the future of mesh research. This update features research that has been conducted since the prior publication to guide surgeons to choose the best and most appropriate mesh for their patients.
Collapse
|