1
|
Lowe CF, Matic N, Ritchie G, Lawson T, Stefanovic A, Champagne S, Leung V, Romney MG. Detection of low levels of SARS-CoV-2 RNA from nasopharyngeal swabs using three commercial molecular assays. J Clin Virol 2020; 128:104387. [PMID: 32380382 PMCID: PMC7187880 DOI: 10.1016/j.jcv.2020.104387] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 04/25/2020] [Indexed: 02/07/2023]
Abstract
In response to the COVID-19 pandemic, commercial molecular assays for SARS-CoV-2 testing have been rapidly developed and broadly deployed in laboratories worldwide. Although these assays have been reported to correlate well, we sought to compare the Xpert® Xpress SARS-CoV-2 to the cobas® SARS-CoV-2 or the Lightmix® Modular SARS and Wuhan CoV E-gene assay for nasopharyngeal (NP) swabs with low levels of SARS-CoV-2 RNA. Thirty-seven NP swabs were studied, including 10 samples with a moderate cycle threshold (Ct) between 30-33.9, and 22 with Ct≥34, and 5 negative for SARS-CoV-2. Overall concordance on initial comparison was 86.5 % (32/37), which was 100 % concordance for samples with Ct values ranging between 30-33.9. Discordance amongst samples showing a Ct ≥34 was 22.7 % (5/22). Endpoint value analysis on the Xpress SARS-CoV-2 within the discordant samples noted two with an endpoint value >5, which were detected by the cobas® or Lightmix®. Testing of SARS-CoV-2 on the three commercial assays was comparable for NP swabs with moderate Ct values, while high Ct values were less concordant. Importantly, analysis of Xpert® endpoint values improved interpretation of discrepant results.
Collapse
|
Validation Study |
5 |
33 |
2
|
Sarkar R. TSH Comparison Between Chemiluminescence (Architect) and Electrochemiluminescence ( Cobas) Immunoassays: An Indian Population Perspective. Indian J Clin Biochem 2014; 29:189-95. [PMID: 24757301 PMCID: PMC3990813 DOI: 10.1007/s12291-013-0339-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2012] [Accepted: 05/05/2013] [Indexed: 10/26/2022]
Abstract
Although 3rd generation TSH assays are the most widely used immunoassays, credible comparison studies, specially involving Indian sub-populations are practically non-existent. To compare the TSH measurements between chemiluminescence (Architect) and electrochemiluminescence (Cobas) inmmunoassays in an urban ambulatory Indian population. 1,615 subjects were selected randomly from the usual laboratory workflow, their TSH measured in Architect and Cobas and the paired data thus generated were statistically analysed. TSH values of Cobas were observed to be higher than the Architect values by 28.7 %, with a significant proportional difference between the two, but majority of the Cobas values (above 90 %) were within the limits of agreement with Architect values. In situations where both the instruments are in use simultaneously, a standardization of the methods is imperative, in larger interest of the patient populace.
Collapse
|
research-article |
11 |
20 |
3
|
DNA extraction from FFPE tissue samples - a comparison of three procedures. Contemp Oncol (Pozn) 2019; 23:52-58. [PMID: 31061638 PMCID: PMC6500389 DOI: 10.5114/wo.2019.83875] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 01/26/2019] [Indexed: 12/29/2022] Open
Abstract
Aim of the study One of the critical steps in molecular oncology diagnostics is obtaining high quality genomic DNA. Therefore, it is important to evaluate and compare the techniques used to extract DNA from tissue samples. Since formalin-fixed, paraffin-embedded (FFPE) tissues are routinely used for both retrospective and prospective studies, we compared three commercially available methods of nucleic acid extraction in terms of quantity and quality of isolated DNA. Material and methods Slides prepared from 42 FFPE blocks were macro-dissected. Resulting material was divided and processed simultaneously using three extraction kits: QIAamp DNA FFPE Tissue Kit (QIAGEN), Cobas DNA Sample Preparation Kit (Roche Molecular Systems) and Maxwell 16 FFPE Plus LEV DNA Purification Kit (Promega). Subsequently, quantity and quality of obtained DNA samples were analysed spectrophotometrically (NanoDrop 2000, Thermo Scientific). Results of quantitative analysis were confirmed by a fluorometric procedure (Qubit 3.0 Fluorometer, Life Technologies). Results The results demonstrated that the yields of total DNA extracted using either Maxwell or Cobas methods were significantly higher compared to the QIAamp method (p < 0.001). The Maxwell Extraction Kit delivered DNA samples of the highest quality (p < 0.01). However, the highest total yield of extracted DNA was achieved with the Cobas technique, which may be due to a higher volume of eluate compared to the Maxwell method. Conclusions To our knowledge, this is the first paper which directly compares three extraction methods: Cobas, Maxwell and QIAamp. The data herein provide information required for the selection of a protocol that best suits the needs of the overall study design in terms of the quantity and quality of the extracted DNA.
Collapse
|
Journal Article |
6 |
16 |
4
|
Boutin CA, Grandjean-Lapierre S, Gagnon S, Labbé AC, Charest H, Roger M, Coutlée F. Comparison of SARS-CoV-2 detection from combined nasopharyngeal/oropharyngeal swab samples by a laboratory-developed real-time RT-PCR test and the Roche SARS-CoV-2 assay on a cobas 8800 instrument. J Clin Virol 2020; 132:104615. [PMID: 32927356 PMCID: PMC7472968 DOI: 10.1016/j.jcv.2020.104615] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Accepted: 08/26/2020] [Indexed: 01/25/2023]
Abstract
OBJECTIVE Although several assays have been developed to detect SARS-CoV-2 RNA in clinical specimens, their relative performance is unknown. METHODS The concordance between the cobas 8800 SARS-CoV-2 and a laboratory developed (LD) reverse transcriptase-polymerase chain reaction (RT-PCR) assay was assessed on 377 combined nasopharyngeal/oropharyngeal swabs in Hanks medium. RESULTS The positive and negative agreement between these assays were 99.3 % (95 % CI, 97.3-99.9) and 77.1 % (95 % CI, 67.7-84.4), respectively, for an overall agreement of 93.6 % (95 % CI, 90.7-95.7) beyond random chance (kappa of 0.82, 95 % CI, 0.75-0.85). Of the 22 samples positive by cobas SARS-CoV-2 only, 9 were positive only for ORF-1 gene and had Cycle thresholds (Ct) > 35.1, 8 were positive only for the E gene with Ct > 35.5 and 5 were positive for both targets with Ct > 33.9. Samples positive only with the cobas assay were more often positive with only one gene target (77.3 %) than samples positive in both assays (16.9 %, p < 0.0001). Ct values in the cobas SARS-CoV-2 assay were significantly higher in the 279 samples testing positive in both assays (32.9 %, 95 % CI 32.3-33.6) compared to the 22 samples with discordant results (36.6 %, 95 % CI 36.2-37.1; p = 0.0009). An excellent correlation (r2 = 0.98) was obtained between Ct values of the ORF-1 and E targets in the cobas assays and a good correlation was obtained between LD RT-PCR test and cobas SARS CoV-2 ORF-1 target (r2 = 0.82). CONCLUSION Our study demonstrated an excellent concordance between a LD RT-PCR and the cobas SARS-CoV-2 tests on the 8800 platform.
Collapse
|
Research Support, Non-U.S. Gov't |
5 |
14 |
5
|
Aretzweiler G, Leuchter S, Simon CO, Marins E, Frontzek A. Generating timely molecular diagnostic test results: workflow comparison of the cobas® 6800/8800 to Panther. Expert Rev Mol Diagn 2019; 19:951-957. [PMID: 31526152 DOI: 10.1080/14737159.2019.1665999] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Background: Molecular diagnostic tests for HBV, HCV and HIV-1 and other pathogens are widely used for clinical management. Practical issues related to workflow and labor requirements need to be characterized to inform selection of the most appropriate system. Research design and methods: We compared the workflow of two high-throughput systems: cobas 6800 (Roche) and Panther (Hologic), using average mid-size laboratory test volumes for five different assays (HIV-1, HBV, HCV, HPV or TV, and CT/NG). Results: Set-up time, time to first results, time to last results, and total hands-on time for cobas 6800 was 0.40, 2.47, 7.12, and 0.98 hours, respectively; on the Panther system, these times were 0.75, 2.7, 9.1, and 1.48 hours. Fifty-seven samples had results available at the first time point on cobas 6800 compared to 5 samples on the Panther system. The Panther system required more manual steps including several with potential risks of contamination or error. The number of reagents items required was 5 for cobas 6800 and 40 for the Panther system. Conclusions: Both systems provided a high level of automation. The cobas 6800 platform had shorter start up, time to first result, time to last result and hands-on times than the Panther system.
Collapse
|
Research Support, Non-U.S. Gov't |
6 |
8 |
6
|
Marins EG, Krey N, Becker A, Melzer S, Hoppler M. Evaluation of the cobas® HCV test for quantifying HCV RNA in dried plasma spots collected using the cobas® Plasma Separation Card. J Virol Methods 2020; 278:113820. [PMID: 31945390 DOI: 10.1016/j.jviromet.2020.113820] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 01/09/2020] [Accepted: 01/11/2020] [Indexed: 12/31/2022]
Abstract
OBJECTIVE This study evaluated the performance of the cobas® hepatitis C virus (HCV) Test for use on the cobas® 6800/8800 Systems for the detection and quantification of HCV RNA collected using the cobas® Plasma Separation Card (PSC) compared with plasma samples. METHODS Whole EDTA-venous blood was collected from 50 HCV-positive donors and 140 μL from each donor was spotted onto a PSC and stored either frozen or at ambient temperature. These were compared with matched EDTA-plasma samples. The limit of detection (LoD) of the assay for PSC samples was determined using serial dilutions of the Roche HCV secondary calibration standard. The stability of the PSC samples across a range of timepoints was also assessed. RESULTS The mean titer difference between ambient and -10 °C storage of PSC samples was 0.04 log10 IU/mL (95% CI: 0.00, 0.07). The mean titer difference between frozen PSC samples and EDTA plasma samples was -1.59 log10 IU/mL (95% CI: -1.66, -1.53) and between ambient PSC samples and EDTA samples was -1.64 log10 IU/mL (95% CI: -1.70, -1.57). Correlation between PSC samples and EDTA plasma was linear in both cases (frozen: slope = 1.039, intercept=-1.839, R2 = 0.89; ambient: slope = 1.012, intercept=-1.712, R2 = 0.88). The LoD of the cobas® HCV Test using the PSC was 866 IU/mL (95% CI: 698, 1153 IU/mL) and 408 IU/mL (95% CI: 336, 544 IU/mL) using an optimized Assay Specific Analysis Package. CONCLUSIONS PSC samples correlate well with plasma viral load and demonstrate a LoD below 1000 IU/mL and good stability at ambient temperature for 28 days. A correction factor would allow quantification of HCV viral RNA load from samples collected using a PSC.
Collapse
|
Research Support, Non-U.S. Gov't |
5 |
8 |
7
|
Diminished amplification of SARS-CoV-2 ORF1ab in a commercial dual-target qRT-PCR diagnostic assay. J Virol Methods 2022; 300:114397. [PMID: 34863783 PMCID: PMC8634734 DOI: 10.1016/j.jviromet.2021.114397] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 11/29/2021] [Accepted: 11/29/2021] [Indexed: 01/04/2023]
Abstract
Here we describe a SARS-CoV-2 variant with diminished amplification of the ORF ORF1ab target in the Cobas® dual-target SARS-CoV-2 assay resulting in a discrepancy of Ct-values (Ct-value 20.7 for the E-gene and Ct-value 30.2 for ORF1ab). Five unique nucleotide mutations were identified in ORF1ab: C11450A (nsp10) C14178T (RdRp), G15006T (RdRp), G18394T (Hel), and G20995T (Hel). This case highlights the importance of surveillance of genomic regions used in molecular diagnostics and the importance of the public release of target regions used to update commercial and in-house developed SARS-CoV-2 PCR tests. This work underpins the importance of using dual-targets in molecular diagnostic assays to limit the change of false-negative results due to primer and/or probe mismatches.
Collapse
|
brief-report |
3 |
6 |
8
|
Matzkies LM, Leitner E, Stelzl E, Assig K, Bozic M, Siebenhofer D, Mustafa ME, Steinmetz I, Kessler HH. Lack of sensitivity of an IVD/CE-labelled kit targeting the S gene for detection of SARS-CoV-2. Clin Microbiol Infect 2020; 26:1417.e1-1417.e4. [PMID: 32652240 PMCID: PMC7345380 DOI: 10.1016/j.cmi.2020.06.036] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 06/29/2020] [Accepted: 06/30/2020] [Indexed: 01/18/2023]
Abstract
OBJECTIVES New molecular tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are being rapidly launched in response to the coronavirus disease 2019 (COVID-19) pandemic. The aim of this study was to evaluate the analytical and clinical performance of the VIASURE SARS-CoV-2 S gene RT-PCR Kit on the BD Max™ system and to compare results with those obtained with the cobas® SARS-CoV-2 test on the cobas® 6800 system. METHODS For testing the analytical performance, reference material was used. Clinical samples (n = 101) obtained from individuals with symptoms compatible with COVID-19 were studied. Oropharyngeal and nasopharyngeal swabs were collected by using either ESwab™ or UTM™ collection systems. RESULTS When the analytical performance was evaluated, the sample containing the lowest SARS-CoV-2 concentration tested negative with the VIASURE test whereas results obtained with the cobas® test were found to be concordant with the results expected. Six out of the 101 clinical samples (5.9%) showed an inhibition with the VIASURE test. When analysing the remaining 95 clinical samples, 27 were found to be negative with both assays. Of 68 samples that were positive with the cobas® test, the VIASURE test missed 21 (30.9 %) samples. All of those 21 samples had shown Ct values ≥ 31 with the cobas® 6800 system. None of the samples tested positive with the VIASURE test and negative with the cobas® test. CONCLUSIONS The VIASURE test was impaired by a lack of sensitivity and a relatively high number of invalid results. When using the VIASURE test for routine testing, a significant number of COVID-19-positive samples would have been missed.
Collapse
|
Journal Article |
5 |
6 |
9
|
Yusrina F, Chua CW, Lee CK, Chiu L, Png TSY, Khoo MJ, Yan G, Lee GH, Yan B, Lee HK. Comparison of cobas HCV GT against Versant HCV Genotype 2.0 (LiPA) with confirmation by Sanger sequencing. J Virol Methods 2018; 255:8-13. [PMID: 29428399 DOI: 10.1016/j.jviromet.2018.02.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Revised: 01/29/2018] [Accepted: 02/04/2018] [Indexed: 12/26/2022]
Abstract
BACKGROUND Correct identification of infecting hepatitis C virus (HCV) genotype is helpful for targeted antiviral therapy. OBJECTIVES Here, we compared the HCV genotyping performance of the cobas HCV GT assay against the Versant HCV Genotype 2.0 (LiPA) assay, using 97 archived serum samples. STUDY DESIGN In the event of discrepant or indeterminate results produced by either assay, the core and NS5B regions were sequenced. RESULTS Of the 97 samples tested by the cobas, 25 (26%) were deemed indeterminate. Sequencing analyses confirmed 21 (84%) of the 25 samples as genotype 6 viruses with either subtype 6m, 6n, 6v, 6xa, or unknown subtype. Of the 97 samples tested by the LiPA, thirteen (13%) were deemed indeterminate. Seven (7%) were assigned with genotype 1, with unavailable/inconclusive results from the core region of the LiPA. Notably, the 7 samples were later found to be either genotype 3 or 6 by sequencing analyses. Moreover, 1 sample by the LiPA was assigned as genotypes 4 (cobas: indeterminate) but were later found to be genotype 3 by sequencing analyses, highlighting its limitation in assigning the correct genotype. CONCLUSIONS The cobas showed similar or slightly higher accuracy (100%; 95% CI 94-100%) compared to the LiPA (99%; 95% CI 92-100%). Twenty-six percent of the 97 samples tested by the cobas had indeterminate results, mainly due to its limitation in identifying genotype 6 other than subtypes 6a and 6b. This presents a significant assay limitation in Southeast Asia, where genotype 6 infection is highly prevalent.
Collapse
|
Journal Article |
7 |
4 |
10
|
Machine Learning Interpretation of Extended Human Papillomavirus Genotyping by Onclarity in an Asian Cervical Cancer Screening Population. J Clin Microbiol 2019; 57:JCM.00997-19. [PMID: 31511337 DOI: 10.1128/jcm.00997-19] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Accepted: 09/09/2019] [Indexed: 11/20/2022] Open
Abstract
This study aimed (i) to compare the performance of the BD Onclarity human papillomavirus (HPV) assay with the Cobas HPV test in identifying cervical intraepithelial neoplasia 2/3 or above (CIN2/3+) in an Asian screening population and (ii) to explore improving the cervical cancer detection specificity of Onclarity by machine learning. We tested 605 stratified random archived samples of cervical liquid-based cytology samples with both assays. All samples had biopsy diagnosis or repeated negative cytology follow-up. Association rule mining (ARM) was employed to discover coinfection likely to give rise to CIN2/3+. Outcome classifiers interpreting the extended genotyping results of Onclarity were built with different underlying models. The sensitivities (Onclarity, 96.32%; Cobas, 95.71%) and specificities (Onclarity, 46.38%; Cobas, 45.25%) of the high-risk HPV (hrHPV) components of the two tests were not significantly different. When HPV16 and HPV18 were used to further interpret hrHPV-positive cases, Onclarity displayed significantly higher specificity (Onclarity, 87.10%; Cobas, 80.77%). Both hrHPV tests achieved the same sensitivities (Onclarity, 90.91%; Cobas, 90.91%) and similar specificities (Onclarity, 48.46%; Cobas, 51.98%) when used for triaging atypical squamous cells of undetermined significance. Positivity in both HPV16 and HPV33/58 of the Onclarity channels entails the highest probability of developing CIN2/3+. Incorporating other hrHPVs into the outcome classifiers improved the specificity of identifying CIN2/3 to up to 94.32%. The extended genotyping of Onclarity therefore can help to highlight patients having the highest risk of developing CIN2/3+, with the potential to reduce unnecessary colposcopy and negative psychosocial impact on women receiving the reports.
Collapse
|
Journal Article |
6 |
4 |
11
|
Hao Y, Mehrotra M, Lam H, Si Q, Salem F, Lu D, Gitman M, Miles B, Posner M, Houldsworth J, Westra WH. Liquid phase human papillomavirus genotype analysis of aspirated metastatic head and neck squamous cell carcinoma: Fine needle aspiration supernatant is a rich source of tumor DNA that can increase the diagnostic yield. Diagn Cytopathol 2020; 49:25-30. [PMID: 32889776 DOI: 10.1002/dc.24603] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 07/31/2020] [Accepted: 08/17/2020] [Indexed: 11/05/2022]
Abstract
BACKGROUND Most patients with human papillomavirus (HPV)-related head and neck squamous cell carcinoma (HNSC) present with lymph node metastasis. In these patients, fine needle aspiration (FNA) is not only a diagnostic tool, but a means for determining HPV status. HPV status, in turn, is used to determine tumor origin, prognosis, and even guide therapy. Thus, the limited sampling afforded by FNA must be optimized to meet heavy clinical demands. PURPOSE The purpose of this study was to determine whether the residual supernatant portion of the FNA could serve as a resource for reliable determination of HPV status DESIGN/METHOD: 25 FNAs from 24 patients with metastatic HNSC underwent HPV genotyping of post-centrifuged supernatant fluid from FNA needle rinses. HPV genotyping was performed using two real time PCR-based assays, the two-step LightCycler and the one-step automated cobas HPV tests. HPV status of the supernatant was compared with the paired FNA cell blocks and/or surgical tissue samples. RESULTS The supernatant was adequate for HPV testing in 24 (96%) of 25 cases. Of these, 14 (56%) were HPV positive and 11 (44%) negative by the LightCycler assay. HPV16 was the most commonly detected genotype (n = 12). When results of supernatant and paired cell block testing were compared, HPV status was concordant in all cases. The LightCycler method was more sensitive than the cobas assay due to its ability to detect an expanded profile of HPV variant genotypes. CONCLUSION The current standard of practice for patients with HNSC who undergo FNA is to construct a cell block and then discard the supernatant. This supernatant is a rich source of tumor DNA that can be used to detect HPV status. It should not be wasted.
Collapse
|
Journal Article |
5 |
2 |
12
|
Voskoboev NV, Cambern SJ, Hanley MM, Giesen CD, Schilling JJ, Jannetto PJ, Lieske JC, Block DR. Fecal electrolyte testing for evaluation of unexplained diarrhea: Validation of body fluid test accuracy in the absence of a reference method. Clin Biochem 2015; 48:1126-30. [PMID: 26093046 DOI: 10.1016/j.clinbiochem.2015.06.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2015] [Revised: 05/22/2015] [Accepted: 06/10/2015] [Indexed: 10/23/2022]
Abstract
BACKGROUND Validation of tests performed on body fluids other than blood or urine can be challenging due to the lack of a reference method to confirm accuracy. The aim of this study was to evaluate alternate assessments of accuracy that laboratories can rely on to validate body fluid tests in the absence of a reference method using the example of sodium (Na(+)), potassium (K(+)), and magnesium (Mg(2+)) testing in stool fluid. METHODS Validations of fecal Na(+), K(+), and Mg(2+) were performed on the Roche cobas 6000 c501 (Roche Diagnostics) using residual stool specimens submitted for clinical testing. Spiked recovery, mixing studies, and serial dilutions were performed and % recovery of each analyte was calculated to assess accuracy. Results were confirmed by comparison to a reference method (ICP-OES, PerkinElmer). RESULTS Mean recoveries for fecal electrolytes were Na(+) upon spiking=92%, mixing=104%, and dilution=105%; K(+) upon spiking=94%, mixing=96%, and dilution=100%; and Mg(2+) upon spiking=93%, mixing=98%, and dilution=100%. When autoanalyzer results were compared to reference ICP-OES results, Na(+) had a slope=0.94, intercept=4.1, and R(2)=0.99; K(+) had a slope=0.99, intercept=0.7, and R(2)=0.99; and Mg(2+) had a slope=0.91, intercept=-4.6, and R(2)=0.91. Calculated osmotic gap using both methods were highly correlated with slope=0.95, intercept=4.5, and R(2)=0.97. Acid pretreatment increased magnesium recovery from a subset of clinical specimens. CONCLUSIONS A combination of mixing, spiking, and dilution recovery experiments are an acceptable surrogate for assessing accuracy in body fluid validations in the absence of a reference method.
Collapse
|
|
10 |
2 |
13
|
Simonson PD, Kim KH, Winston-McPherson G, Parakh RS, Yamaguchi D, Merrill AE, Dickerson JA, Greene DN. Characterization of bilirubin interference in three commonly used digoxin assays. Clin Biochem 2018; 63:102-105. [PMID: 30316751 DOI: 10.1016/j.clinbiochem.2018.10.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Revised: 10/09/2018] [Indexed: 11/30/2022]
Abstract
BACKGROUND Due to the narrow therapeutic range of digoxin, determining serum/plasma digoxin concentrations is critical for assessing patients with congestive heart failure, atrial fibrillation, and certain types of arrhythmias. However, digoxin quantification by competitive immunoassays is susceptible to interferences that may alter the accuracy of its measurement in patient plasma. This study aimed to characterize the extent of bilirubin interference in three commonly used digoxin immunoassays. METHODS Digoxin concentrations were compared using the Beckman Coulter® Unicel DxI 800, the Vitros® 4600, and the Roche Cobas® 8000 in neat or digoxin-spiked icteric and non-icetric plasma samples. A mixing study was performed to demonstrate how digoxin quantification is affected by bilirubin. An equation was derived that predicts the response of the DxI 800, given known bilirubin and digoxin concentrations. RESULTS The DxI reported detectable concentrations of digoxin in high bilirubin samples with no added digoxin, while the Vitros® 4600 and Cobas® 8000 gave virtually undetectable results. Spiking digoxin into samples with elevated bilirubin concentrations resulted in a higher percent recovery for the DxI 800 when compared to the other two platforms. The mixing study also revealed an increase in the percent recovery in the DxI 800, while the Vitros® 4600 and Cobas® 8000 were comparable to the expected concentration of digoxin. CONCLUSIONS The DxI 800 is most prone to interference by bilirubin, while the Vitros® 4600 and Cobas® 8000 are relatively unaffected. Icteric samples should be interpreted with caution if digoxin quantification is needed, especially on the DxI 800 assay.
Collapse
|
|
7 |
2 |
14
|
Comparison of the clinical and analytical performance of Alinity m HR HPV and cobas 4800 HPV assays in a population-based screening setting. J Clin Virol 2021; 140:104851. [PMID: 34020361 DOI: 10.1016/j.jcv.2021.104851] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 04/29/2021] [Accepted: 05/01/2021] [Indexed: 12/27/2022]
Abstract
BACKGROUND The recently launched Abbott Alinity m HR HPV (Alinity) assay separately identifies high-risk human papillomavirus (hrHPV) genotypes HPV16, HPV18, and HPV45, and reports 11 other genotypes as two aggregates. METHODS Clinical and analytical performance of Alinity was compared with the cobas 4800 HPV assay on 4,334 women aged 20-64 years attending routine, population-based organized cervical cancer screening during 2009/2010. After 36 months, they were invited to participate in the second screening round (2012-2014) and later followed-up through centralized national cervical cancer screening registry. RESULTS In women 30 and older, the clinical sensitivity for cervical intraepithelial neoplasia grade 2+ (CIN2+) was 100.0% (95% CI, 88.2-100.0%) for Alinity and 100.0% (95% CI, 88.2-100.0%) for cobas, and for CIN3+ 100.0% (95% CI, 78.9-100.0%) for both assays. The clinical specificity for ≤ CIN1 in women 30 and older was 92.4% (95% CI, 91.4-93.3%) and 92.9% (95% CI, 91.9-93.7%), respectively. The assays demonstrated excellent overall agreement for hrHPV detection (97.9%) and genotype-specific agreement for HPV16 (99.6%), HPV18 (99.8%), and other hrHPV (98.1%). Overall positive agreement and positive agreements for HPV16, HPV18, and other hrHPV genotypes were 84.3%, 89.1%, 73.2%, and 82.3%. Based on a 5-year CIN3+ risk, slightly more HPV-positive women would require referral to immediate colposcopy after testing with Alinity vs. cobas (4.1% vs. 3.8%; p = 0.470), but significantly fewer Alinity-tested women would need a 6- to 12-month follow-up visit compared with those tested with cobas (5.0% vs. 8.6%; p < 0.0001). CONCLUSIONS Alinity and cobas have comparable clinical performance and showed excellent overall and genotype-specific agreement. The Alinity's extended genotyping ability could help predict the 5-year CIN3+ risk and cost-saving management of HPV-screen-positive women.
Collapse
|
Journal Article |
4 |
1 |
15
|
[Comparative study of the serum measurement of PTH on Roche Cobas e411 ® versus the Abbott Architect ci8200 ®]. Ann Biol Clin (Paris) 2018; 76:61-67. [PMID: 29243659 DOI: 10.1684/abc.2017.1309] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Parathormone (PTH) is the main hormone of phosphocalcic homeostasis. It is synthesized and secreted by the parathyroid glands. PTH has become a routine test in the medical biology laboratory. However, its measurement presents analytical difficulties with the various marketed kits. The aim of this work is to present the results of a comparative study between the PTH measurment on Abbott architect ci8200 and on Roche's Cobas e411 automaton. It is a prospective study carried out for 252 hospitalized patients in the various departments of the University Hospital Center Mohammed VI of Oujda. The "intact" PTH tests were performed on two automata: Abbott Architect ci8200 and Roche Cobas e411. The first uses chemiluminescent microparticle immunoassay. The second uses electrochemiluminiscence sandwich enzyme immunoassay. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line (MedCalc software version 14.8.1.0®). By analyzing the diagram of Bland-Altman, we note that the average bias between both methods is of the order of 193.9 pg/mL. As for the equation of the right of Passing-Bablok, it is: Y(Architect) = 3.11 X (Cobas) - 12.26. In conclusion, our study shows a great discrepancy between the results of the PTH assay on the Architect ci8200 versus the Cobas e411, hence the biologist's indisputable role in the control and evaluation of the kits marketed through the various validation tests.
Collapse
|
Journal Article |
7 |
1 |
16
|
Kogo M, Fujimoto D, Hosoya K, Nagata K, Nakagawa A, Tachikawa R, Yamashita D, Kitamura Y, Imai Y, Tomii K. Tumour content ratio matters for detecting epidermal growth factor receptor mutation by cobas test in small biopsies; a retrospective study. BMC Cancer 2020; 20:104. [PMID: 32028905 PMCID: PMC7006383 DOI: 10.1186/s12885-020-6603-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Accepted: 02/04/2020] [Indexed: 11/15/2022] Open
Abstract
Background Recent studies indicate the benefit of treatment with osimertinib over that with conventional epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors (TKI) for untreated EGFR-mutated non-small cell lung cancer (NSCLC). Cobas ver2 is the only companion diagnostic method for detecting EGFR mutations with osimertinib treatment. We clinically experience false negative cases with this test, but its actual sensitivity is unknown. Moreover, no study has suggested the importance of tumour dissection, and most facilities do not routinely perform them on small biopsies. The purpose of this study was to evaluate the sensitivity of cobas in clinical practice and clarify the role of dissection as a component of the cobas testing. Methods We examined 132 patients with EGFR-mutated NSCLC diagnosed by bronchoscopy and confirmed with PCR clamp. Patients were tested with cobas and the EGFR-positive rate was calculated. Samples with undetected EGFR mutations were retested after tumour dissection and the rate of samples whose EGFR mutation was corrected to positive was assessed. To evaluate tumour cellularity, the tumour content ratio was assessed by calculating tumour cell count over the total cell count on the slide. Results The positive rate of EGFR mutation identification was 76% with cobas, although EGFR mutation-negative patients retained responses to TKI therapy equivalent to positive patients did; however, the tumour content ratio of negative samples was significantly lower than that of positive samples. Twenty-nine negative samples underwent dissection and 24% were corrected to positive. Moreover, 53% of the samples with a tumour content ratio below 10% was negative for cobas, but 33% of these turned positive after dissection. Conclusions Cobas had a high false negative rate in clinical practice, and tumour content ratio might be associated with this rate. Dissection could improve the sensitivity of cobas, especially in samples with low tumour cellularity.
Collapse
|
Journal Article |
5 |
1 |
17
|
Pryce TM, Boan PA, Kay ID, Flexman JP. Qualitative and quantitative effects of thermal treatment of naso-oropharyngeal samples before cobas SARS-CoV-2 testing. Diagn Microbiol Infect Dis 2021; 101:115519. [PMID: 34571354 PMCID: PMC8382495 DOI: 10.1016/j.diagmicrobio.2021.115519] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 08/08/2021] [Accepted: 08/11/2021] [Indexed: 02/08/2023]
Abstract
To improve laboratory safety we thermally treated naso-oropharyngeal samples before testing with the cobas SARS-CoV-2 assay. This study aimed to determine if thermal treatment significantly affects the qualitative detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the quantitative measurement of cobas SARS-CoV-2 ORF1a and E-gene target copy number using an in-house quantitative method. A collection of positive (n = 238) and negative samples (n = 196) was tested in parallel comparing thermal treatment (75 °C for 15 minutes) to room-temperature. There were no significant differences in the final qualitative outcomes for thermal treatment versus room-temperature (99.8% agreement) despite a statistically significant reduction (P < 0.05) in target copy number following thermal treatment. The median ORF1a and E-gene reduction in target copy number was 0.07 (1.6%) and 0.22 (4.2%) log10 copies/mL respectively. The standard curves for both ORF1a and E-gene targets were highly linear (r2 = 0.99). Good correlation was observed for ORF1a (r2 = 0.96) and E-gene (r2 = 0.98) comparing thermal treatment to room-temperature control.
Collapse
|
|
4 |
1 |
18
|
Windrichova J, Broz P, Fuchsova R, Topolcan O, Pecen L, Mayer O, Kucera R. Comparison of four routinely used vitamin D automated immunoassays. J Med Biochem 2021; 40:277-285. [PMID: 34177372 PMCID: PMC8199437 DOI: 10.5937/jomb0-27531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Accepted: 11/05/2020] [Indexed: 11/09/2022] Open
Abstract
Background To compare four automated immunoassays for the measurement of 25(OH)-vitamin D (25-OHD) and to assess the impact on the results obtained from a healthy population. Methods We analysed 100 serum samples on Unicel DxI 800 (Beckman Coulter), Architect i1000 (Abbott), Cobas e411 (Roche) and Liaison XL (DiaSorin). Passing-Bablok regression and Bland-Altman plots were used for method comparison. In order to categorise the obtained values, results were categorised into the following groups: 0-25 nmol/L, 25-50 nmol/L, 50-75 nmol/L and above 75 nmol/L and compared. The percentage of samples below 75 nmol/L, and below 50 nmol/L was then calculated for every method. Results According to paired comparisons, each method differs from others (p<0.0001) except Cobas vs Architect, which do not show a statistically significant difference (p=0.39). The strongest correlation was found between Liaison and Architect (ρ=0.94, p<0.0001). The percentage of samples below the recommended value of 75 nmol/L were: 70% (Architect), 92% (Liaison), 71% (Cobas) and 89% (Unicel). The percentage of samples below the value of 50 nmol/L were: 17% (Architect), 55% (Liaison), 28% (Cobas) and 47% (Unicel). Conclusions The observed differences stem from the use of different analytical systems for 25-OHD concentration analysis and can result in different outcomes. The recommended values should be established for each assay in accordance with the data provided by the manufacturer or in the laboratory, in accordance with proper standardisation.
Collapse
|
Journal Article |
4 |
|
19
|
Zungsontiporn N, Ouwongprayoon P, Boonsirikamchai P, Leelayuwatanakul N, Vinayanuwattikun C, Moonai K, Khongkhaduead E, Thorner PS, Shuangshoti S, Teerapakpinyo C. Detection of EGFR T790M mutation using liquid biopsy for non-small cell lung cancer: Utility of droplet digital polymerase chain reaction vs. cobas real-time polymerase chain reaction. Pathol Res Pract 2024; 255:155213. [PMID: 38394807 DOI: 10.1016/j.prp.2024.155213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 02/03/2024] [Accepted: 02/15/2024] [Indexed: 02/25/2024]
Abstract
BACKGROUND Digital platforms for mutation detection yield higher sensitivity than non-digital platforms but lack universal positive cut-off values that correlate with the outcome of osimertinib treatment. This study determined compared droplet digital polymerase chain reaction (ddPCR) to the standard cobas assay for epithelial growth factor receptor (EGFR) T790M mutation detection in patients with non-small cell lung cancer. METHODS Study patients had EGFR-mutant tumours with disease progression on first/second generation EGFR tyrosine kinase inhibitors, and osimertinib treatment after T790M mutation detection. T790M status was tested by cobas assay using liquid biopsy, and only by ddPCR if an EGFR mutation was identified but T790M was negative. Clinical efficacy of osimertinib was compared between patients with T790M detected by cobas vs. only by ddPCR. A positive cut-off value for ddPCR was determined by assessing efficacy with osimertinib. RESULTS 61 patients had tumors with an acquired T790M mutation, 38 detected by cobas and an additional 23 only by ddPCR. The median progression-free survival (PFS) for the cobas- and ddPCR-positive groups was 9.5 and 7.8 months, respectively (p=0.43). For ddPCR, a fractional abundance (FA) of 0.1% was used as a cut-off value. The median PFS of patients with FA ≥0.1% and <0.1% was 8.3 and 4.6 months, respectively (p=0.08). FA ≥0.1% was independently associated with a longer PFS. CONCLUSION Using ddPCR to follow up the cobas assay yielded more cases (38% of total) with a T790M mutation. A cut-off value of FA ≥0.1% identified patients who responded as well to osimertinib as those identified by cobas assay. This sequential approach should detect additional patients who might benefit from osimertinib treatment.
Collapse
|
|
1 |
|
20
|
Zhou W, Rowe L, Witt B, Deftereos G. Application of the Roche Cobas® HPV 4800 in Formalin-Fixed, Paraffin-Embedded Samples for Head and Neck Squamous Cell Carcinomas. Head Neck Pathol 2021; 15:532-536. [PMID: 33128730 PMCID: PMC8134591 DOI: 10.1007/s12105-020-01240-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 10/16/2020] [Indexed: 10/23/2022]
Abstract
Testing for high risk human papillomavirus (HR-HPV) status is standard of care in squamous cell carcinomas of the oropharynx as well as cervical lymph node squamous cell carcinomas of unknown primary origin. DNA or RNA in-situ hybridization (ISH) and p16 immunohistochemistry, widely used currently for HPV detection are operator-dependent. In addition, DNA ISH has a relatively low sensitivity, and p16 is not entirely specific for HR-HPV infection. In this study, we examined the performance of the cobas® HPV genotyping assay in formalin-fixed, paraffin-embedded (FFPE) samples of head and neck squamous cell carcinoma. FFPE samples from head neck and other anatomic sites tested by ISH and p16 for HR-HPV at ARUP Laboratories were selected for this study. Samples were deparaffinized, stained and micro-dissected for tumor contents followed by tissue lysis, then tested with cobas® for HR-HPV. All the samples were also tested by HPV Linear Array for confirmation. All (N = 18) high risk HPV positive specimens tested by cobas® were confirmed as positive by the Linear Array test. All the specimens tested as negative by cobas® were tested as negative (N = 5) or positive only for low risk HPV (N = 3) by Linear Array, as cobas® only detects HR HPV. Limits of detection for HPV16 and 18 were established at 160-320 and 320-1600 copies, respectively. Our data suggest that cobas® HR-HPV genotyping is a viable option for detection of HR-HPV in formalin-fixed, paraffin-embedded samples from head and neck and other anatomic sites and has been validated for clinical use.
Collapse
|
research-article |
4 |
|
21
|
Navarathna DH, Sayers KB, Murray DC. Impact of improper sample handling on Cobas CT/NG testing platform with dual swab sample collection kit for detecting Chlamydia trachomatis and Neisseria gonorrhoeae. Microbiol Spectr 2024; 12:e0322423. [PMID: 38047699 PMCID: PMC10783118 DOI: 10.1128/spectrum.03224-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 10/23/2023] [Indexed: 12/05/2023] Open
Abstract
IMPORTANCE The importance of this observation lies in its potential to directly impact testing outcomes and patient care. By identifying improper sample handling as a contributing factor to a substantial number of invalid results, we emphasize the need for meticulous adherence to recommended protocols during sample collection. Laboratories that overlook or are unaware of such deviations may inadvertently compromise the reliability and efficacy of their diagnostic processes, leading to misdiagnoses, delayed treatment, and patient dissatisfaction.
Collapse
|
brief-report |
1 |
|
22
|
Nilyanimit P, Chaithongwongwatthana S, Oranratanaphan S, Poudyal N, Excler JL, Lynch J, Vongpunsawad S, Poovorawan Y. Comparable detection of HPV using real-time PCR in paired cervical samples and concentrated first-stream urine collected with Colli-Pee device. Diagn Microbiol Infect Dis 2024; 108:116160. [PMID: 38184985 PMCID: PMC10877071 DOI: 10.1016/j.diagmicrobio.2023.116160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/05/2023] [Accepted: 12/11/2023] [Indexed: 01/09/2024]
Abstract
We compared high-risk human papillomavirus (HPV) detection on first-stream urine from self-sampled collection device (Colli-Pee) and same-day clinician-collected cervical swab in 240 women. Testing with automated cobas 4800 system showed 96.7 % concordance (198 concordant-negative, 34 concordant-positive, Cohen's kappa=0.87). HPV testing on Colli-Pee urine offers advantages for acceptable non-invasive HPV screening.
Collapse
|
|
1 |
|