1
|
Wahlquist JA, DelRio FW, Randolph MA, Aziz AH, Heveran CM, Bryant SJ, Neu CP, Ferguson VL. Indentation mapping revealed poroelastic, but not viscoelastic, properties spanning native zonal articular cartilage. Acta Biomater 2017; 64:41-49. [PMID: 29037894 DOI: 10.1016/j.actbio.2017.10.003] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2017] [Revised: 09/07/2017] [Accepted: 10/03/2017] [Indexed: 02/07/2023]
Abstract
Osteoarthrosis is a debilitating disease affecting millions, yet engineering materials for cartilage regeneration has proven difficult because of the complex microstructure of this tissue. Articular cartilage, like many biological tissues, produces a time-dependent response to mechanical load that is critical to cell's physiological function in part due to solid and fluid phase interactions and property variations across multiple length scales. Recreating the time-dependent strain and fluid flow may be critical for successfully engineering replacement tissues but thus far has largely been neglected. Here, microindentation is used to accomplish three objectives: (1) quantify a material's time-dependent mechanical response, (2) map material properties at a cellular relevant length scale throughout zonal articular cartilage and (3) elucidate the underlying viscoelastic, poroelastic, and nonlinear poroelastic causes of deformation in articular cartilage. Untreated and trypsin-treated cartilage was sectioned perpendicular to the articular surface and indentation was used to evaluate properties throughout zonal cartilage on the cut surface. The experimental results demonstrated that within all cartilage zones, the mechanical response was well represented by a model assuming nonlinear biphasic behavior and did not follow conventional viscoelastic or linear poroelastic models. Additionally, 10% (w/w) agarose was tested and, as anticipated, behaved as a linear poroelastic material. The approach outlined here provides a method, applicable to many tissues and biomaterials, which reveals and quantifies the underlying causes of time-dependent deformation, elucidates key aspects of material structure and function, and that can be used to provide important inputs for computational models and targets for tissue engineering. STATEMENT OF SIGNIFICANCE Elucidating the time-dependent mechanical behavior of cartilage, and other biological materials, is critical to adequately recapitulate native mechanosensory cues for cells. We used microindentation to map the time-dependent properties of untreated and trypsin treated cartilage throughout each cartilage zone. Unlike conventional approaches that combine viscoelastic and poroelastic behaviors into a single framework, we deconvoluted the mechanical response into separate contributions to time-dependent behavior. Poroelastic effects in all cartilage zones dominated the time-dependent behavior of articular cartilage, and a model that incorporates tension-compression nonlinearity best represented cartilage mechanical behavior. These results can be used to assess the success of regeneration and repair approaches, as design targets for tissue engineering, and for development of accurate computational models.
Collapse
|
Research Support, N.I.H., Extramural |
8 |
38 |
2
|
Pérez-Sáez MJ, Herrera S, Prieto-Alhambra D, Vilaplana L, Nogués X, Vera M, Redondo-Pachón D, Mir M, Güerri R, Crespo M, Díez-Pérez A, Pascual J. Bone density, microarchitecture, and material strength in chronic kidney disease patients at the time of kidney transplantation. Osteoporos Int 2017; 28:2723-2727. [PMID: 28497224 DOI: 10.1007/s00198-017-4065-5] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Accepted: 04/19/2017] [Indexed: 10/19/2022]
Abstract
UNLABELLED Bone health is assessed by bone mineral density (BMD). Other techniques such as trabecular bone score and microindentation could improve the risk of fracture's estimation. Our chronic kidney disease (CKD) patients presented worse bone health (density, microarchitecture, mechanical properties) than controls. More than BMD should be done to evaluate patients at risk of fracture. INTRODUCTION BMD measured by dual-energy X-ray absorptiometry (DXA) is used to assess bone health in end-stage renal disease (ESRD) patients. Recently, trabecular bone score (TBS) and microindentation that can measure microarchitectural and mechanical properties of bone have demonstrated better correlation with fractures than DXA in different populations. We aimed to characterize bone health (BMD, TBS, and strength) and calcium/phosphate metabolism in a cohort of 53 ESRD patients undergoing kidney transplantation (KT) and 94 controls with normal renal function. METHODS Laboratory workout, lumbar spine/hip BMD measurements (using DXA), lumbar spine TBS, and bone strength were carried out. The latter was assessed with an impact microindentation device, standardized as percentage of a reference value, and expressed as bone material strength index (BMSi) units. Multivariable linear regression was used to study differences between cases and controls adjusted by age, gender, and body mass index. RESULTS Among cases, serum calcium was 9.6 ± 0.7 mg/dl, phosphorus 4.4 ± 1.2 mg/dl, and intact parathyroid hormone 214 pg/ml [102-390]. Fourteen patients (26.4%) had prevalent asymptomatic fractures in spinal X-ray. BMD was significantly lower among ESRD patients compared to controls: lumbar 0.966 ± 0.15 vs 0.982 ± 0.15 (adjusted p = 0.037), total hip 0.852 ± 0.15 vs 0.902 ± 0.13 (adjusted p < 0.001), and femoral neck 0.733 ± 0.15 vs 0.775 ± 0.12 (adjusted p < 0.001), as were TBS (1.20 [1.11-1.30] vs 1.31 [1.19-1.43] (adjusted p < 0.001)) and BMSi (79 [71.8-84.2] vs 82. [77.5-88.9] (adjusted p = 0.005)). CONCLUSIONS ESRD patients undergoing transplant surgery have damaged bone health parameters (density, microarchitecture, and mechanical properties) despite acceptably controlled hyperparathyroidism. Detecting these abnormalities may assist in identifying patients at high risk of post-transplantation fractures.
Collapse
|
|
8 |
36 |
3
|
Arnold M, Zhao S, Ma S, Giuliani F, Hansen U, Cobb JP, Abel RL, Boughton O. Microindentation - a tool for measuring cortical bone stiffness? A systematic review. Bone Joint Res 2017; 6:542-549. [PMID: 28924020 PMCID: PMC5631024 DOI: 10.1302/2046-3758.69.bjr-2016-0317.r2] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Accepted: 07/07/2017] [Indexed: 01/26/2023] Open
Abstract
Objectives Microindentation has the potential to measure the stiffness of an individual patient’s bone. Bone stiffness plays a crucial role in the press-fit stability of orthopaedic implants. Arming surgeons with accurate bone stiffness information may reduce surgical complications including periprosthetic fractures. The question addressed with this systematic review is whether microindentation can accurately measure cortical bone stiffness. Methods A systematic review of all English language articles using a keyword search was undertaken using Medline, Embase, PubMed, Scopus and Cochrane databases. Studies that only used nanoindentation, cancellous bone or animal tissue were excluded. Results A total of 1094 abstracts were retrieved and 32 papers were included in the analysis, 20 of which used reference point indentation, and 12 of which used traditional depth-sensing indentation. There are several factors that must be considered when using microindentation, such as tip size, depth and method of analysis. Only two studies validated microindentation against traditional mechanical testing techniques. Both studies used reference point indentation (RPI), with one showing that RPI parameters correlate well with mechanical testing, but the other suggested that they do not. Conclusion Microindentation has been used in various studies to assess bone stiffness, but only two studies with conflicting results compared microindentation with traditional mechanical testing techniques. Further research, including more studies comparing microindentation with other mechanical testing methods, is needed before microindentation can be used reliably to calculate cortical bone stiffness. Cite this article: M. Arnold, S. Zhao, S. Ma, F. Giuliani, U. Hansen, J. P. Cobb, R. L. Abel, O. Boughton. Microindentation – a tool for measuring cortical bone stiffness? A systematic review. Bone Joint Res 2017;6:542–549. DOI: 10.1302/2046-3758.69.BJR-2016-0317.R2.
Collapse
|
Journal Article |
8 |
21 |
4
|
Setters A, Jasiuk I. Towards a standardized reference point indentation testing procedure. J Mech Behav Biomed Mater 2014; 34:57-65. [PMID: 24556325 DOI: 10.1016/j.jmbbm.2014.01.012] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2013] [Revised: 01/16/2014] [Accepted: 01/18/2014] [Indexed: 11/30/2022]
Abstract
We study the reference point indentation (RPI) technique which has a potential to directly measure mechanical properties of bone in patients. More specifically, we tested 6 month swine femoral cortical bone at mid-diaphysis region to investigate the effect of several testing variables on the RPI outputs. They include the force magnitude, preconditioning, variation within a sample and between samples, number of cycles, indentation surface (transverse versus longitudinal, polished versus unpolished), and micro-computed tomography radiation exposure. The force magnitude variation test shows that all RPI parameters increase linearly with the increasing force magnitude except the indentation distance increase which shows a cubic trend with a plateau for force magnitudes between 4N and 8N. Preconditioning does not affect the trends for a force magnitude variation test. The cycle variation test shows that most RPI parameters reach either a maximum or minimum at 15-20 cycles. Transverse surface measurements are more consistent than the longitudinal surface measurements, but a rough surface and periosteum on the longitudinal surface could account for this difference. Exposure to the micro-computed tomography radiation in general does not have effect on the RPI measurements. For the 6 month swine femoral cortical bone, testing using 6N force and 20 cycles with preconditioning on an unpolished longitudinal surface is recommended. This study advances our knowledge on how the RPI testing variables influence the RPI outputs and provides guidance on the RPI measurements. It may also serve as a framework for developing a standardized testing procedure for the RPI technique.
Collapse
|
Research Support, Non-U.S. Gov't |
11 |
19 |
5
|
Nogués X, Prieto-Alhambra D, Güerri-Fernández R, Garcia-Giralt N, Rodriguez-Morera J, Cos L, Mellibovsky L, Pérez AD. Fracture during oral bisphosphonate therapy is associated with deteriorated bone material strength index. Bone 2017; 103:64-69. [PMID: 28655603 DOI: 10.1016/j.bone.2017.06.018] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Revised: 06/18/2017] [Accepted: 06/22/2017] [Indexed: 12/15/2022]
Abstract
BACKGROUND Some patients experience fractures while receiving oral bisphosphonates (BPs) treatment. Clinical risk factors, advanced bone density loss, and microarchitecture deterioration have been associated with such fractures but bone tissue properties other than bone mineral density (BMD) have not been assessed. METHODS In a cross-sectional study of postmenopausal women on bisphosphonates for at least 4years with good adherence to treatment, 21 patients with incident fractures were compared with 18 treated patients without new fractures. Demographic and clinical variables, BMD, laboratory tests, and bone material strength index (BMSi) assessed by impact microindentation at the tibial diaphysis were recorded for all participants. RESULTS Clinical and laboratory results did not differ between patients taking BPs with incident fractures and those without new fractures. However, BMSi was significantly lower (mean±SD) in those who fractured (73.76±6.49) than in no-fracture patients (81.64±6.26; p=0.001). Lumbar spine (LS) BMD was also lower in fractured patients (p=0.03). Adjusted models including age, body mass index, years on BP treatment, and LS-BMD confirmed an increase in fracture risk per BMSi standard deviation decrease: adjusted OR 23.5 [95% CI 2.16 to 255.66], p=0.01. ROC analyses showed an area under the curve of 0.82 (95% CI 0.68 to 0.95) for BMSi, higher than that for BMD at any location, which ranged from 0.64 (95% CI 0.47 to 0.82) for femoral neck (FN) BMD to 0.71 (95% CI 0.55 to 0.87) for LS-BMD. CONCLUSIONS Patients who fracture while receiving BPs treatment have worse BMSi scores than BP-treated patients without fractures. The potential for BMSi to provide an additional osteoporosis treatment target should be explored.
Collapse
|
|
8 |
18 |
6
|
Variability in reference point microindentation and recommendations for testing cortical bone: location, thickness and orientation heterogeneity. J Mech Behav Biomed Mater 2015; 46:292-304. [PMID: 25837158 DOI: 10.1016/j.jmbbm.2015.02.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Revised: 02/03/2015] [Accepted: 02/07/2015] [Indexed: 11/24/2022]
Abstract
Reference Point Indentation (RPI) has been proposed as a new clinical tool to aid the diagnosis of Osteoporosis. This study has examined the performance of the tool within entire femurs to improve the understanding of the mechanical properties of bone and also to guide future RPI testing to optimize repeatability of results obtained using the technique. Human, bovine, porcine and rat femurs were indented along three longitudinal axes: anterior and posterior: medial and lateral as well as around the circumference of the femoral head and neck. Cortical and subchondral bone thickness was measured using CT and radiography. The study shows that in some samples, bone is too thin to support the high loads applied with the technique and in these cases, RPI values are highly influenced by thickness. The technique will be useful in the mid-shaft region where cortical thickness is greatest, providing previously established guidelines are followed to optimize measurement repeatability, including performing multiple measurements per sample and investigating multiple samples. The study has also provided evidence that RPI values vary significantly with test site, hence mechanical properties should not be inferred from RPI findings alone away from the test site, even within the same bone. In conclusion, RPI appears to be a useful tool for scientific investigation; however further work is required to examine the feasibility of using RPI for assessing differences between healthy and diseased bone in a clinical setting.
Collapse
|
Research Support, Non-U.S. Gov't |
10 |
15 |
7
|
Jenkins T, Coutts LV, Dunlop DG, Oreffo ROC, Cooper C, Harvey NC, Thurner PJ. Variability in reference point microindentation and recommendations for testing cortical bone: maximum load, sample orientation, mode of use, sample preparation and measurement spacing. J Mech Behav Biomed Mater 2015; 42:311-24. [PMID: 25455607 DOI: 10.1016/j.jmbbm.2014.09.030] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Revised: 09/19/2014] [Accepted: 09/27/2014] [Indexed: 10/24/2022]
Abstract
Reference Point Indentation (RPI) is a novel microindentation tool that has emerging clinical potential for the assessment of fracture risk as well as use as a laboratory tool for straight-forward mechanical characterisation of bone. Despite increasing use of the tool, little research is available to advise the set-up of testing protocols or optimisation of testing parameters. Here we consider five such parameters: maximum load, sample orientation, mode of use, sample preparation and measurement spacing, to investigate how they affect the Indentation Distance Increase (IDI), the most published measurement parameter associated with the RPI device. The RPI tool was applied to bovine bone; indenting in the proximal midshaft of five femora and human bone; indenting five femoral heads and five femoral neck samples. Based on the findings of these studies we recommend the following as the best practice. (1) Repeat measurements should be utilised to reduce the coefficient of variation (e.g. 8-15 repeats to achieve a 5-10% error, however the 3-5 measurements used here gives a 15-20% error). (2) IDI is dependent on maximum load (r=0.45 on the periosteal surface and r=0.94 on the machined surface, p<0.05), mode of use (i.e. comparing the device held freehand compared to fixed in its stand, p=0.04) and surface preparation (p=0.004) so these should be kept consistent throughout testing. Though sample orientation appears to have minimal influence on IDI (p>0.05), care should also be taken in combining measurements from different orientations. (3) The coefficient of variation is higher (p=0.04) when holding the device freehand, so it should ideally be kept supported in its stand. (4) Removing the periosteum (p=0.04) and machining the surface of the bone (p=0.08) reduces the coefficient of variation, so should be performed where practical. (5) There is a hyperbolic relationship between thickness and IDI (p<0.001) with a sample thickness 10 fold greater than the maximum indentation depth recommended, to ensure a representative measurement. (6) Measurement spacing does not appear to influence the IDI (p>0.05), so it can be as low as 500 µm. By following these recommendations, RPI users can minimise the potential confounding effects associated with the variables investigated here and reduce the coefficient of variation, hence achieving more consistent testing. This optimisation of the technique enhances both the clinical and laboratory potential of the tool.
Collapse
|
|
10 |
15 |
8
|
Variability of in vivo reference point indentation in skeletally mature inbred rats. J Biomech 2014; 47:2504-7. [PMID: 24856912 DOI: 10.1016/j.jbiomech.2014.04.035] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 04/17/2014] [Accepted: 04/21/2014] [Indexed: 11/22/2022]
Abstract
Reference point indentation (RPI) has emerged as a novel tool to measure material-level biomechanical properties in vivo. Human studies have been able to differentiate fracture versus non-fracture patients while a dog study has shown the technique can differentiate drug treatment effects. The goal of this study was to extend this technology to the in vivo measurement of rats, one of the most common animal models used to study bone, with assessment of intra- and inter-animal variability. Seventy-two skeletally mature male Sprague-Dawley rats were subjected to in vivo RPI on the region between the tibial diaphysis and proximal metaphysis. RPI data were assessed using a custom MATLAB program to determine several outcome parameters, including first cycle indentation distance (ID-1st), indentation distance increase (IDI), total indentation distance (TID), first cycle unloading slope (US-1st), and first cycle energy dissipation (ED-1st). Intra-animal variability ranged from 13% to 21% with US-1st and Tot Ed 1st-L being the least variable properties and IDI the most highly variable. Inter-animal variability ranged from 16% (US-1st) to 25% (ED-1st and IDI). Based on these data, group size estimates would need to range from 9 to 18/group to achieve sufficient power for detecting a 25% difference in a two-group experiment. Repeat tests on the contralateral limb of a small cohort of animals (n=17) showed non-significant differences over 28 days ranging from -6% to -18%. These results provide important data on RPI variability (intra- and inter-animal) in rats that can be used to properly power future experiments using this technique.
Collapse
|
Research Support, Non-U.S. Gov't |
11 |
13 |
9
|
Ballesta S, Güerri-Fernández RC, Chillarón JJ, Güell A, Herrera S, Torres E, Ascoeta NG, Flores Le-Roux JA, Díez A. The use of microindentation for the study of bone properties in type 1 diabetes mellitus patients. Osteoporos Int 2020; 31:175-180. [PMID: 31641800 DOI: 10.1007/s00198-019-05178-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Accepted: 09/24/2019] [Indexed: 11/27/2022]
Abstract
UNLABELLED Diabetes mellitus is associated with a higher risk of fracture. In this study, we analysed the bone quality of premenopausal women with type 1 diabetes mellitus by microindentation. No differences in bone quality were identified between patients and healthy controls, suggesting that intensive insulin therapy can preserve bone health. PURPOSE To compare the bone quality of women with type 1 diabetes mellitus (T1DM) and healthy controls, and to determine the relationship with bone mineral density (BMD). METHODS This was a cross-sectional study of 45 premenopausal women with T1DM and 21 healthy controls, matched according to age and BMI. Clinical parameters, BMD and bone tissue mechanical properties (assessed using the bone material strength index [BMSi]) were evaluated in each group using microindentation. In T1DM patients, glycosylated haemoglobin (HbA1c), the number of hypoglycaemic events and the status of chronic complications were also analysed. RESULTS No differences in BMSi or BMD between T1DM patients and healthy controls were identified. In the T1DM patients, the mean HbA1c was 7.52% ± 1.00% and the mean time elapsed since diagnosis was 22.6 ± 12.2 years. Eight patients (17.7%) met the criteria for metabolic syndrome (MetS), and microvascular complications were present in 12 patients (26.7%). Neither the number of features of MetS present nor the presence of microangiopathy was found to be associated with BMSi. CONCLUSIONS T1DM premenopausal patients showed bone tissue properties comparable to those shown by controls. Further larger-scale studies should be conducted to confirm these results.
Collapse
|
|
5 |
10 |
10
|
Chow DHK, Wang J, Wan P, Zheng L, Ong MTY, Huang L, Tong W, Tan L, Yang K, Qin L. Biodegradable magnesium pins enhanced the healing of transverse patellar fracture in rabbits. Bioact Mater 2021; 6:4176-4185. [PMID: 33997501 PMCID: PMC8099917 DOI: 10.1016/j.bioactmat.2021.03.044] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Revised: 03/29/2021] [Accepted: 03/29/2021] [Indexed: 12/20/2022] Open
Abstract
Displaced fractures of patella often require open reduction surgery and internal fixation to restore the extensor continuity and articular congruity. Fracture fixation with biodegradable magnesium (Mg) pins enhanced fracture healing. We hypothesized that fixation with Mg pins and their degradation over time would enhance healing of patellar fracture radiologically, mechanically, and histologically. Transverse patellar fracture surgery was performed on thirty-two 18-weeks old female New Zealand White Rabbits. The fracture was fixed with a pin made of stainless steel or pure Mg, and a figure-of-eight stainless steel band wire. Samples were harvested at week 8 or 12, and assessed with microCT, tensile testing, microindentation, and histology. Microarchitectural analysis showed that Mg group showed 12% higher in the ratio of bone volume to tissue volume at week 8, and 38.4% higher of bone volume at week 12. Tensile testing showed that the failure load and stiffness of Mg group were 66.9% and 104% higher than the control group at week 8, respectively. At week 12, Mg group was 60.8% higher in ultimate strength than the control group. Microindentation showed that, compared to the Control group, Mg group showed 49.9% higher Vickers hardness and 31% higher elastic modulus at week 8 and 12, respectively. At week 12, the new bone of Mg group remodelled to laminar bone, but those of the control group remained woven bone-like. Fixation of transverse patellar fracture with Mg pins and its degradation enhanced new bone formation and mechanical properties of the repaired patella compared to the Control group.
Kirschner wires (K-wire) with tension band wire is widely used fixation implants for repairing of displaced patellar fractures. Fixation of patellar fracture with Mg pins enhanced new bone formation and mechanical properties of the repaired patella. With a stainless steel tension band wire, Mg pins may be an alternative to K-wire for fixation of patellar fractures.
Collapse
|
Journal Article |
4 |
8 |
11
|
Pérez-Sáez MJ, Herrera S, Prieto-Alhambra D, Vilaplana L, Nogués X, Vera M, Redondo-Pachón D, Mir M, Güerri R, Crespo M, Díez-Pérez A, Pascual J. Maintenance low dose systemic glucocorticoids have limited impact on bone strength and mineral density among incident renal allograft recipients: A pilot prospective cohort study. Bone 2018; 116:290-294. [PMID: 30145341 DOI: 10.1016/j.bone.2018.08.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 08/06/2018] [Accepted: 08/20/2018] [Indexed: 01/14/2023]
Abstract
Soon after kidney transplant (KT), a decrease in parathormone and bone mineral density (BMD) occur, but little is known on the impact of KT on novel bone quality parameters including trabecular bone score (TBS) and bone material strength index (BMSi). We aimed to study BMD, TBS and BMSi in the first year after KT, in patients not treated with any bone therapy. A cohort including 36 patients underwent KT on a low-glucocorticoid-dose protocol (5 mg daily-prednisone from post-operative-day 42 onwards) and was observed for 12 months prospectively. At 3 months, phosphorus and parathormone decreased, while calcium increased. We also observed at 3 months a transient mild 2.9% bone loss at femoral neck (BMD change 0.752 ± 0.15 vs 0.730 ± 0.15; p = 0.004), but no change at either spine or total hip. Both TBS and BMSi remained stable. At 12 months, lumbar (but not total hip or femoral neck) BMD slightly decreased by 2.1% vs baseline (0.950 ± 0.15 vs 0.930 ± 0.5; p = 0.046), while TBS and BMSi remained unmodified. In KT patients on low-dose glucocorticoids and no bone therapy, there were small BMD decreases at femoral neck (at 3 months) and lumbar spine (at 12 months), but no change in either TBS or BMSi. Low-dose post-KT glucocorticoid treatment shows limited impact on bone, supporting steroid-restrictive protocols.
Collapse
|
|
7 |
8 |
12
|
Arevalo SE, Pruitt LA. Nanomechanical analysis of medical grade PEEK and carbon fiber-reinforced PEEK composites. J Mech Behav Biomed Mater 2020; 111:104008. [PMID: 32805544 DOI: 10.1016/j.jmbbm.2020.104008] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 07/19/2020] [Accepted: 07/21/2020] [Indexed: 01/23/2023]
Abstract
Polyether ether ketone (PEEK) and PEEK composites are viable candidates for orthopedic implants owing to their ability for modulus match of surrounding bone tissue. The structural properties of these systems for load-bearing application in the body can be tailored by incorporating carbon fibers; to this end, polyacrylonitrile (PAN) and pitch fibers are commonly incorporated in the PEEK matrix. Mechanical property optimization for a given medical application requires consideration of carbon fiber type and volume fraction, as well as processing conditions for the composite systems. While much is known about the bulk mechanical properties of PEEK and PEEK composites, little is known about the nanomechanical properties of these systems. Insight into nanoscale behavior can offer valuable information about fiber-matrix interactions that may influence long-term integrity of these biomaterials when used in load bearing medical device applications. In this study, we utilize nanoindentation as a method to characterize mechanical behavior of clinical grade PEEK and PEEK composites. We examine PEEK formulations with pitch and PAN fibers and evaluate a range of thermal treatments known to influence polymer microstructure. We use a conospherical tip of 1.5 μm in radius and a conospherical tip of 20 μm radius to determine indentation modulus over different length scales. We correlate these findings with previous characterization on these same PEEK systems using microindentation. A novelty of this work is that we combine nanoindentation with k-means clustering to quantitatively discern the influence of heat treatment and carbon fiber type on the mechanical behavior of PEEK composites and their constituents. We demonstrate that nanoindentation is an effective characterization tool for discerning fiber-matrix interactions and measuring the mechanical behavior in response to thermal treatment and carbon fiber type in PEEK composites. Nanoindentation is shown to be a viable tool for characterizing complex biomaterials and can serve as an effective technique to guide optimization of microstructures for long-term structural applications in the body.
Collapse
|
|
5 |
8 |
13
|
Saiworn W, Thim-Uam A, Visitchanakun P, Atjanasuppat K, Chantaraaumporn J, Mokdara J, Chungchatupornchai S, Pisitkun P, Leelahavanichkul A, Poolthong S, Baron R, Lotinun S. Cortical Bone Loss in a Spontaneous Murine Model of Systemic Lupus Erythematosus. Calcif Tissue Int 2018; 103:686-697. [PMID: 30116830 DOI: 10.1007/s00223-018-0464-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2018] [Accepted: 08/08/2018] [Indexed: 01/10/2023]
Abstract
Patients with systemic lupus erythematosus (SLE), a chronic inflammatory disease characterized by loss of T- and B-cell tolerance to autoantigens, are at increased risk for osteoporosis and fractures. Mice deficient in Fc gamma receptor IIb (FcγRIIB) exhibit spontaneous SLE and its restoration rescues the disease. To determine whether deleting FcγRIIB affects cortical bone mass and mechanical properties, we analyzed cortical bone phenotype of FcγRIIB knockouts at different ages. FACS analysis revealed that 6-month-old FcγRIIB-/- mice had increased B220lowCD138+ cells, markers of plasma cells, indicating active SLE disease. In contrast, 3-month-old FcγRIIB-/- mice did not develop the active SLE disease. µCT analysis indicated that FcγRIIB deletion did not affect cortical bone in 3-month-old mutants. However, 6- and 10-month-old FcγRIIB-/- males and females had osteopenic cortical bone and the severity of bone loss increased with disease duration. FcγRIIB deletion decreased cross-sectional area, cortical area, and marrow area in 6-month-old males. Cortical area and cortical thickness were decreased in 10-month-old FcγRIIB-/- males. Lack of FcγRIIB decreased cortical thickness without affecting cortical area in females. However, deletion of a single FcγRIIB allele was insufficient to induce cortical bone loss. The bending strength was decreased in 6- and 10-month-old FcγRIIB-deficient males compared to WT controls. A microindentation analysis demonstrated significantly decreased hardness in both 10-month-old FcγRIIB-/- males and females. Our data indicate that FcγRIIB contributes to the regulation of cortical bone homeostasis subsequent to SLE development and that deletion of FcγRIIB in mice leads to SLE-like disease associated with cortical bone loss and decreased bending strength and hardness.
Collapse
|
|
7 |
7 |
14
|
Comparison of macro-, micro- and nanomechanical properties of clinically-relevant UHMWPE formulations. J Mech Behav Biomed Mater 2020; 120:104205. [PMID: 34058599 DOI: 10.1016/j.jmbbm.2020.104205] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 11/08/2020] [Accepted: 11/10/2020] [Indexed: 11/21/2022]
Abstract
We characterized a set of eleven clinically relevant formulations of UHMWPE for total joint replacements. Although their molecular and supermolecular structure were quite similar as evidenced by IR, DSC and SAXS measurements, there were slight differences in their crystallinity (DSC crystallinity ranging from 52 to 61%), which were connected with processing conditions, such as the total radiation dose, thermal treatment and/or addition of biocompatible stabilizers. Mechanical properties were assessed at all length scales, using macroscale compression testing, non-instrumented and instrumented microindentation hardness testing (at loading forces ~500 mN), and nanoindentation hardness testing measured at both higher and lower loading (~4 mN and ~0.6 mN, respectively). In agreement with theoretical predictions, we found linear correlations between UHMWPE crystallinity and its stiffness-related properties (elastic moduli, yield stress, and hardness) at all length scales (macro-, micro- and nanoscale). Detailed statistical evaluation of our dataset showed that the accuracy and precision of the applied methods decreased in the following order: non-instrumented microindentation ≥ instrumented microindentation ≥ macromechanical properties ≥ nanoindentation measured at higher loading forces ≫ nanoindentation measured at lower loading forces. The results confirm that microindentation and nanoindentation at sufficiently high loading forces are reliable methods, suitable for UHMWPE characterization.
Collapse
|
Research Support, Non-U.S. Gov't |
5 |
6 |
15
|
Majda M, Sapala A, Routier-Kierzkowska AL, Smith RS. Cellular Force Microscopy to Measure Mechanical Forces in Plant Cells. Methods Mol Biol 2019; 1992:215-230. [PMID: 31148041 DOI: 10.1007/978-1-4939-9469-4_14] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Cellular force microscopy (CFM) is a noninvasive microindentation method used to measure plant cell stiffness in vivo. CFM is a scanning probe microscopy technique similar in operation to atomic force microscopy (AFM); however, the scale of movement and range of forces are much larger, making it suitable for stiffness measurements on turgid plant cells in whole organs. CFM experiments can be performed on living samples over extended time periods, facilitating the exploration of the dynamics of processes involving mechanics. Different sensor technologies can be used, along with a variety of probe shapes and sizes that can be tailored to specific applications. Measurements can be made for specific indentation depths, forces and timing, allowing for very precise mechanical stimulation of cells with known forces. High forces with sharp tips can also be used for mechanical ablation of cells with force feedback.
Collapse
|
|
6 |
5 |
16
|
Schwiedrzik JJ, Mirzaali MJ, Thaiwichai S, Best JP, Michler J, Zysset PK, Wolfram U. Response to the commentary on mechanical properties of cortical bone and their relationships with age, gender, composition and microindentation properties in the elderly. Bone 2017; 105:312-314. [PMID: 27712993 DOI: 10.1016/j.bone.2016.09.025] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2016] [Revised: 09/26/2016] [Accepted: 09/28/2016] [Indexed: 11/20/2022]
|
Letter |
8 |
4 |
17
|
Beketova A, Varitis S, Kontonasaki E, Zorba T, Papadopoulou L, Kantiranis N, Theodorou GS, Paraskevopoulos KM, Koidis P. Evaluation of the micro-mechanical and bioactive properties of bioactive glass-dental porcelain composite. J Mech Behav Biomed Mater 2018; 86:77-83. [PMID: 29957447 DOI: 10.1016/j.jmbbm.2018.06.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Revised: 06/08/2018] [Accepted: 06/12/2018] [Indexed: 02/06/2023]
Abstract
The aim of this study was to evaluate microhardness and elastic modulus of a novel sol-gel derived dental ceramic - 58S bioactive glass composite (BP67: Bioactive Glass:33.3%, Dental Ceramic:66.7%) BP671 material by micro-indentation and to investigate its microstructure and bioactivity. The research hypotheses were that the values of microhardness (1) and elastic modulus (2) of the novel bioceramic composite and the commercial dental ceramic will be of the same order. The experimental sol-gel derived ceramics showed similar microstructural characteristics to a commercial feldspathic porcelain, and presence of additional calcium phosphate phases, which contributed its bioactivity. The formation of an apatite-like layer on the materials' surface observed by Fourier Transform Infrared (FTIR)2 spectroscopy, X-ray Diffraction (XRD)3 and Scanning Electron Microscopy-Energy Dispersive Spectroscopy (SEM-EDS)4 techniques after 12 days of maintenance in Conventional Simulated Body Fluid (cSBF)5 solution. The BP67 exhibited values of microhardness and modulus of elasticity which were not statistically significant different compared to dental ceramic, indicating the adequate mechanical integrity of the material. The results of this study suggest that the novel bioactive composite could be potentially applied in prosthetic dentistry, while its thermal and optical properties should be investigated in future studies.
Collapse
|
|
7 |
4 |
18
|
Yuh C, O'Bryan CS, Angelini TE, Wimmer MA. Microindentation of cartilage before and after articular loading in a bioreactor: assessment of length-scale dependency using two analysis methods. EXPERIMENTAL MECHANICS 2021; 61:1069-1080. [PMID: 35528779 PMCID: PMC9075500 DOI: 10.1007/s11340-021-00742-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 06/04/2021] [Indexed: 06/14/2023]
Abstract
BACKGROUND Microindentation is a technique with high sensitivity and spatial resolution, allowing for measurements at small-scale indentation depths. Various methods of indentation analysis to determine output properties exist. OBJECTIVE Here, the Oliver-Pharr Method and Hertzian Method were compared for stiffness analyses of articular cartilage at varying length-scales before and after bioreactor loading. METHODS Using three different conospherical tips with varying radii (20, 100, 793.75 μm), a bioreactor-indenter workflow was performed on cartilage explants to assess changes in stiffness due to articular loading. For all data, both the Oliver-Pharr Method and Hertzian Method were applied for indentation analysis. RESULTS The reduced moduli calculated by the Hertzian Method were found to be similar to those of the Oliver-Pharr Method when the 20 μm tip size was used. The reduced moduli calculated using the Hertzian Method were found to be consistent across the varying length-scales, whereas for the Oliver-Pharr Method, adhesion/suction led to the largest tip exhibiting an increased average reduced modulus compared to the two smaller tips. Loading induced stiffening of articular cartilage was observed consistently, regardless of tip size or indentation analysis applied. CONCLUSIONS Overall, geometric linearity is preserved across all tip sizes for the Hertzian Method and may be assumed for the two smaller tip sizes using the Oliver-Pharr Method. These findings further validate the previously described stiffening response of the superficial zone of cartilage after articular loading and demonstrate that the finding is length-scale independent.
Collapse
|
research-article |
4 |
4 |
19
|
Transient stiffening of cartilage during joint articulation: A microindentation study. J Mech Behav Biomed Mater 2020; 113:104113. [PMID: 33032010 DOI: 10.1016/j.jmbbm.2020.104113] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 08/23/2020] [Accepted: 09/24/2020] [Indexed: 11/21/2022]
Abstract
As a mechanoactive tissue, articular cartilage undergoes compression and shear on a daily basis. With the advent of high resolution and sensitive mechanical testing methods, such as micro- and nanoindentation, it has become possible to assess changes in small-scale mechanical properties due to compression and shear of the tissue. However, investigations on the changes of these properties before and after joint articulation have been limited. To simulate articular loading of cartilage in the context of human gait, a previously developed bioreactor system was used. Immediately after bioreactor testing, the stiffness was measured using microindentation. Specifically, we investigated whether the mechanical response of the tissue was transient or permanent, dependent on counterface material, and an effect limited to the superficial zone of cartilage. We found that cartilage surface stiffness increases immediately after articular loading and returns to baseline values within 3 hr. Cartilage-on-cartilage stiffening was found to be higher compared to both alumina- and cobalt chromium-on-cartilage stiffening, which were not significantly different from each other. This stiffening response was found to be unique to the superficial zone, as articular loading on cartilage with the superficial zone removed showed no changes in stiffness. The findings of this study suggest that the cartilage superficial zone may adapt its stiffness as a response to articular loading. As the superficial zone is often compromised during the course of osteoarthritic disease, this finding is of clinical relevance, suggesting that the load-bearing function deteriorates over time.
Collapse
|
Research Support, U.S. Gov't, Non-P.H.S. |
5 |
3 |
20
|
Herrera S, Soriano R, Nogués X, Güerri-Fernandez R, Grinberg D, García-Giralt N, Martínez-Gil N, Castejón S, González-Lizarán A, Balcells S, Diez-Perez A. Discrepancy between bone density and bone material strength index in three siblings with Camurati-Engelmann disease. Osteoporos Int 2017; 28:3489-3493. [PMID: 28842728 DOI: 10.1007/s00198-017-4198-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2017] [Accepted: 08/14/2017] [Indexed: 10/19/2022]
Abstract
UNLABELLED Camurati-Engelmann (CE) is a very rare disease affecting one in every million persons worldwide. It is characterized by an enlargement of long bones. We aimed to assess bone characteristics in three siblings with different tools. Even if there was an excess of bone density, quality seemed to be deteriorated. INTRODUCTION CE disease is a rare monogenic disorder affecting approximately one in every million persons worldwide. It is mainly characterized by a progressive hyperostosis of the periosteum and endosteum of the diaphysis of long bones. Limited data are available about bone characteristics in these patients. In three siblings with CE disease, we aimed to assess bone mineral density (BMD) and trabecular bone score (TBS) by dual-energy X-ray absorptiometry (DXA) and material characteristics at tissue level using bone impact reference point indentation. METHODS Clinical data were collected and a general laboratory workup was performed. At the lumbar spine and hip, BMD and TBS were measured using DXA imaging. Bone material strength index (BMSi) was measured by bone impact microindentation using an Osteoprobe instrument. RESULTS All three cases had densitometric values consistent with high bone mass (sum of Z-score at the lumbar spine and hip > 4). Hip BMD was extremely high in all three siblings at both total hip and femoral neck, while at the lumbar spine, two of them had normal values but the third again had very high BMD. TBS values were in the normal range. In contrast, BMSi measurements were at low or very low levels, compared with normal controls. CONCLUSION Despite strikingly increased BMD and normal microarchitecture, BMSi is affected in patients with CE. Microindentation could be an appropriate tool for assessing bone fragility in these patients. Bone disease in this group of patients requires further study to better understand the underlying regulatory mechanisms and their alterations.
Collapse
|
Case Reports |
8 |
3 |
21
|
Kundanati L, D'Incau M, Bernardi M, Scardi P, Pugno NM. A comparative study of the mechanical properties of a dinosaur and crocodile fossil teeth. J Mech Behav Biomed Mater 2019; 97:365-374. [PMID: 31158580 DOI: 10.1016/j.jmbbm.2019.05.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 05/15/2019] [Accepted: 05/16/2019] [Indexed: 11/15/2022]
Abstract
Vertebrate teeth are complex structures adapted in terms of shape and structure to serve a variety of functions like biting and grinding. Thus, examining the morphology, composition and mechanical properties of the teeth can aid in providing insights into the feeding behaviour of extinct species. We here provide the first mechanical characterisation of teeth in a spinosaurid dinosaur, Suchomimus tenerensis, and a pholidosaurid crocodylomorph, Sarcosuchus imperator. Our results show that both species have similar macrostructure of enamel, dental and interfacial layers, and similar composition, the main constituent being fluorapatite. Microindentation tests show that Suchomimus teeth have lower elastic modulus and hardness, as compared to Sarchosuchus. On the contrary, Sarcosuchus teeth have lower toughness. Nanoindentation showed the existence of mechanical gradients from dentin to enamel in Suchomimus and, less prominently, in Sarcosuchus. This was also supported by wear tests showing that in Suchomimus the dentin region is more wear-prone than the enamel region. With still scarce information available on the dietary regimes in extinct species, the analysis of micro and nano-mechanical properties of fossils teeth might be a help in targeting specific biological questions. However, much is still unknown concerning the changes underwent by organic material during diagenesis making at present impossible to definitely conclude if the differences in the mechanical properties of Suchomimus and Sarchosuchus here retrieved imply that the two species adopted different strategies when dealing with food processing or are the result of disparate taphonomic histories.
Collapse
|
Comparative Study |
6 |
2 |
22
|
Chawla D, Eriten M, Henak CR. Effect of osmolarity and displacement rate on cartilage microfracture clusters failure into two regimes. J Mech Behav Biomed Mater 2022; 136:105467. [PMID: 36198233 DOI: 10.1016/j.jmbbm.2022.105467] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 08/16/2022] [Accepted: 09/12/2022] [Indexed: 11/22/2022]
Abstract
Articular cartilage is a poroviscoelastic (PVE) material with remarkable resistance to fracture and fatigue failure. Cartilage failure mechanisms and material properties that govern failure are incompletely understood. Because cartilage is partially comprised of negatively charged glycosaminoglycans, altering solvent osmolarity can influence PVE relaxations. Therefore, this study aims to use osmolarity as a tool to provide additional data to interpret the role of PVE relaxations and identify cartilage failure regimes. Cartilage fracture was induced using a 100 μm radius spheroconical indenter at controlled displacement rates under three different osmolarity solvents. Secondarily, contact pressure (CP) and strain energy density (SED) were estimated to cluster data into two failure regimes with an expectation maximization algorithm. Critical displacement, critical load, critical time, and critical work to fracture increased with increasing osmolarity at a slow displacement rate whereas no significant effect was observed at a fast displacement rate. Clustering provided two distinct failure regimes, with regime (I) at lower normalized thickness (contact radius divided by sample thickness), and regime (II) at higher normalized thickness. Varied CP and SED in regime (I) suggest that failure in the regime is strain-governed. Constant CP and SED in regime (II) suggests that failure in the regime is dominantly governed by stress. These regimes can be interpreted as ductile versus brittle, or using a pressurized fragmentation interpretation. These findings demonstrated fundamental failure properties and postulate failure regimes for articular cartilage.
Collapse
|
|
3 |
2 |
23
|
Vogler H, Burri JT, Nelson BJ, Grossniklaus U. Simultaneous measurement of turgor pressure and cell wall elasticity in growing pollen tubes. Methods Cell Biol 2020; 160:297-310. [PMID: 32896323 DOI: 10.1016/bs.mcb.2020.04.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Plant growth and morphogenesis are tightly controlled processes of division and expansion of individual cells. To fully describe the factors that influence cell expansion, it is necessary to quantify the counteracting forces of turgor pressure and cell wall stiffness, which together determine whether and how a cell expands. Several methods have been developed to measure these parameters, but most of them provide only values for one or the other, and thus require complex models to derive the missing quantity. Furthermore, available methods for turgor measurement are either accurate but invasive, like the pressure probe; or they lack accuracy, such as incipient plasmolysis or indentation-based methods that rely on information about the mechanical properties of the cell wall. Here, we describe a system that overcomes many of the above-mentioned disadvantages using growing pollen tubes of Lilium longiflorum as a model. By combining non-invasive microindentation and cell compression experiments, we separately measure turgor pressure and cell wall elasticity on the same pollen tube in parallel. Due to the modularity of the setup and the large range of the micro-positioning system, our method is not limited to pollen tubes but could be used to investigate the biomechanical properties of many other cell types or tissues.
Collapse
|
|
5 |
2 |
24
|
Taylor V, Hicks J, Ferguson C, Willey J, Danelson K. Effects of tissue culture on the biomechanical properties of porcine meniscus explants. Clin Biomech (Bristol, Avon) 2019; 69:120-126. [PMID: 31330461 PMCID: PMC7303885 DOI: 10.1016/j.clinbiomech.2019.06.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Revised: 06/12/2019] [Accepted: 06/28/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND The meniscus is critical for the normal functioning of the knee joint. The specific aim of this study was to validate an in vitro culture model of meniscus explants for testing the impact of culture conditions on meniscus biomechanical properties. We hypothesized that culturing menisci in the presence of intermediate and high concentration of serum would have a positive effect on the compressive stiffness of the meniscus. METHODS Unconstrained microindentation testing was performed on porcine meniscus explants cultured with varying concentrations 1%, 5%, or 10% of fetal bovine serum media. Meniscus explants that were not cultured were used as a control. These tests quantified the Young's Modulus of the listed groups of cultured and uncultured explant tissues. FINDINGS The Young's modulus for 10% cultured explants were significantly higher compared to the control, 1%, and 5% cultured meniscus explants. There was no statistical significance when the Young's modulus between control, 1%, and 5% cultured explants were compared. INTERPRETATION These results suggest that low concentrations of serum do not impart an anabolic effect on meniscus tissue explant biomechanical properties.
Collapse
|
research-article |
6 |
2 |
25
|
Abstract
Fractures are the result of the application of a greater force on bone than its strength. Therefore, to understand fracture physiopathology, it is essential to know bone strength determinants. These include bone mineral density (BMD), bone spatial structure (bone geometry and microarchitecture) and bone mechanical and tissue properties. While BMD and bone spatial structure can be easily evaluated through imaging technology, assessment of bone tissue and mechanical properties is complex and typically requires invasive techniques that are not suitable in clinical practice. Microindentation is a relatively recently developed technique that directly measures bone tissue and mechanical properties in patients in a fast, safe, feasible and minimally invasive way. It appears to be particularly informative in diseases associated with an increased risk of fracture not explained by BMD values as occurs in X-linked hypophosphataemia (XLH). The aim of this article is to provide an overview on bone microindentation and its potential utility in the evaluation of patients with XLH.
Collapse
|
Review |
5 |
1 |