Would CLSI M53-A have helped in the diagnosis of HIV in Canada? Results of the performance of Canadian laboratories participating in a recent NLHRS proficiency testing panel containing HIV-1 antigen positive (antibody negative) and HIV-2 samples.
J Clin Virol 2013;
58:303-5. [PMID:
23890809 DOI:
10.1016/j.jcv.2013.04.009]
[Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2013] [Revised: 03/25/2013] [Accepted: 04/08/2013] [Indexed: 01/15/2023]
Abstract
INTRODUCTION
The Clinical and Laboratory Standards Institute recently published M53-A, Criteria for Laboratory Testing and Diagnosis of Human Immunodeficiency Virus (HIV) Infection; Approved Guideline (2011), which includes a state of the art algorithm for identifying HIV-1 acute and HIV-2 infections. To assess the ability of Canadian laboratories to detect these sample types and the impact of M53-A, the National Laboratory for HIV Reference Services distributed a special proficiency testing panel.
METHODS
HIVS425-2012Nov22 was sent to 42 laboratories across Canada. It contained one HIV negative sample (B), two HIV-1 positive samples (A and E), one HIV-2 positive sample (C) and one HIV-1/2 antibody negative-HIV-1 antigen positive sample (D). Data was collected and analyzed using DigitalPT; a standardized on-line tool.
RESULTS
Forty-one laboratories returned results. Sample B (HIV negative) was identified by 95% of laboratories (39/41) and samples A and E (HIV-1 positive) by 98% (40/41). No laboratory identified sample C as HIV-2 positive, although 85% (35/41) detected reactivity prompting a referral for further testing. The remaining laboratories identified sample C as HIV-1 positive (4), indeterminate (1) or gave no final status (1). Sample D (HIV antibody negative-antigen positive) was correctly identified by two laboratories as HIV-1 antigen positive while 78% (32/41) detected reactivity, recommending further testing. One laboratory did not provide a final status. Alarmingly, six laboratories called this sample HIV negative.
CONCLUSION
Although there is a high quality of HIV testing across Canada, introduction of the M53-A guideline would further improve the ability of laboratories to diagnose HIV-1 acute and HIV-2 infection.