1
|
Simultaneous Post and Cone Fractures of a Polyethylene Insert in a Mobile-Bearing Posterior-Stabilized Total Knee Arthroplasty. Arthroplast Today 2024; 26:101316. [PMID: 38389865 PMCID: PMC10881304 DOI: 10.1016/j.artd.2024.101316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Revised: 01/05/2024] [Accepted: 01/13/2024] [Indexed: 02/24/2024] Open
Abstract
We report a novel case of the simultaneous post and cone fractures of a polyethylene (PE) insert in a mobile-bearing posterior-stabilized total knee arthroplasty. Twelve years after the primary total knee arthroplasty, the 72-year-old male patient presented with a recurring right knee instability and was diagnosed with the wear of the PE insert based on physical and radiological examinations. Revision surgery was performed. The post and cone of the PE insert had fractured simultaneously. Moreover, the femoral and tibial components were in direct contact with each other. One year post-revision, knee function had improved. To diagnose a PE breakage, such as a post or cone fracture, surgeons should consider the possibility of PE breakage even in the absence of pain since patients might complain of subjective instability only.
Collapse
|
2
|
Can pain be improved with retention of the posterior cruciate ligament during total knee arthroplasty? EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2023; 33:3395-3401. [PMID: 37140671 DOI: 10.1007/s00590-023-03562-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 04/23/2023] [Indexed: 05/05/2023]
Abstract
PURPOSE The purpose of the current study was to determine if differences exist between cruciate-retaining (CR) and posterior-stabilized (PS) implant articulations for total knee arthroplasty (TKA) with regards to early post-operative pain. METHODS We retrospectively reviewed patients who underwent primary TKA, with the same TKA implant design, at our institution between January 2018 and July 2021. Patients were stratified based on whether they received a CR or non-constrained PS (PSnC) articulation and propensity score matched in a 1:1 ratio. A sub-analysis matching patient who received a constrained PS implant (PSC) to those undergoing CR TKA and PSnC TKA was also carried out. Opioid dosages were converted to morphine milligram equivalents (MME). RESULTS 616 patients after CR TKA were matched 1:1 to 616 patients with a PSnC implant. There were no significant differences between demographic variables. There were no statistically significant differences in opioid usage measured by MME on post-operative day (POD) 0 (p = 0.171), POD1 (p = 0.839), POD2 (p = 0.307), or POD3 (p = 0.138); VAS pain scores (p = 0.175); or 90-day readmission rate for pain (p = 0.654). A sub-analysis of CR versus PSC TKA demonstrated no significant differences in opioid usage on POD0 (p = 0.765), POD1 (p = 0.747), POD2 (p = 0.564), POD3 (p = 0.309); VAS pain scores (p = 0.293); and 90-day readmission rate for pain (p > 0.9). CONCLUSION Our analysis demonstrated no significant difference in post-operative VAS pain scores and MME usage based on implant. The results suggest that neither the type of articulation or constraint used for primary TKA has a significant impact on immediate post-operative pain and opioid consumption. LEVEL III EVIDENCE Retrospective Cohort Study.
Collapse
|
3
|
Favorable outcomes of posterior cruciate-stabilized inserts over ultracongruent inserts in total knee arthroplasty. Arch Orthop Trauma Surg 2023; 143:5857-5865. [PMID: 36928502 DOI: 10.1007/s00402-023-04837-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 02/28/2023] [Indexed: 03/18/2023]
Abstract
OBJECTIVE Posterior cruciate-stabilized (PS) and ultracongruent (UC) inserts are used during total knee arthroplasty (TKA), but superiority in gaining postoperative knee flexion and functionality remains contested. Therefore, this study compared postoperative outcomes between PS and UC inserts. METHODS A retrospective review evaluated unilateral or bilateral TKAs with PS or UC inserts from August 2011 to March 2020. Nonparametric statistics were performed to evaluate differences in patient demographics, pre- and postknee flexion and Knee Society Knee (KSS-K) and Function Score (KSS-F). Univariate and multivariable regressions were performed to evaluate the influence on postoperative knee flexion ≥ 120°, presented as odds ratios (OR) and 95% confidence intervals (CI). RESULTS Patient demographics were not significantly different between the 577 PS and 399 UC knees evaluated. Postoperatively, a larger proportion of UC knees demonstrated knee flexion < 120° (36.0% vs. 18.6%, p < 0.001) and lower KSS-K (91.0 ± 8.7 vs. 91.6 ± 10.3, p < 0.001) and KSS-F (76.8 ± 21.6 vs. 79.9 ± 21.6, p = 0.007) than the PS group. The PS group had greater improvement in flexion angle (4.9° ± 14.9° vs. 1.0° ± 15.6°, p < 0.001) and KSS-F (27.3 ± 23.3 vs. 23.1 ± 25.3, p = 0.007) as compared to that of UC patients. Patients with preoperative flexion < 120° (OR 2.787, CI 2.066-3.761; p < 0.001), higher body mass index (OR 1.033, CI 1.006-1.061; p = 0.017) and UC insert (OR 2.461, CI 1.832-3.307; p < 0.001) were less likely to achieve flexion ≥ 120°. CONCLUSION Favorable clinical and functional outcomes were noted in the PS group as compared to UC inserts in TKA. The greater improvement in overall knee flexion may suggest the PS insert may be especially appropriate for patients with lower preoperative range of motion. LEVEL OF EVIDENCE III, retrospective comparative study.
Collapse
|
4
|
No higher tibial post fracture rate with highly cross-linked polyethylene inserts in total knee arthroplasty at a minimum 10-year follow-up. Arch Orthop Trauma Surg 2023; 143:5807-5813. [PMID: 36720735 DOI: 10.1007/s00402-023-04789-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 01/22/2023] [Indexed: 02/02/2023]
Abstract
PURPOSE The purpose of this study was to assess tibial post fracture between highly cross-linked polyethylene (HXPE) and conventional polyethylene inserts in consecutive posterior-stabilized (PS) total knee arthroplasty (TKA) over a minimum 10-years follow-up period. METHODS Between July 2008 and December 2011, a consecutive series of 3264 primary TKAs was performed in 2098 patients using a PS total knee prosthesis at a single institution. The final cohort was classified into the HXPE group (792 cases) and the conventional group (2113 cases) according to insert material used during the procedure. RESULTS The mean follow-up period was 11.4 years in the HXPE group and 11.8 years in the conventional group. Both cases of tibial post fracture occurred in the HXPE group, a complication rate of 0.25%. These two cases required replacement with a thicker tibial insert with retention of the femoral and tibial components. There were no cases of tibial post fracture in the conventional group. CONCLUSION There was no difference in tibial post fracture rate between the HXPE group and the conventional group in PS TKA on long-term follow-up. LEVEL OF EVIDENCE IV.
Collapse
|
5
|
Bicruciate-retaining total knee arthroplasty non-inferior to posterior-stabilized prostheses after 5 years: a randomized, controlled trial. Knee Surg Sports Traumatol Arthrosc 2023; 31:1034-1042. [PMID: 36329189 DOI: 10.1007/s00167-022-07210-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 10/24/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE Bicruciate-retaining (BCR) prostheses may improve satisfaction of patient undergoing total knee arthroplasty (TKA). The objective of this randomized controlled trial was to assess whether BCR prostheses provide better clinical outcomes than posterior-stabilized (PS) prostheses. MATERIALS AND METHODS This is a randomized single-blind control trial involving a total of 77 patients with knee osteoarthritis, randomly assigned to undergo TKA with a BCR or PS implant between 2015 and 2019. Mean follow-up period was 39 months. Clinical and demographic data were extracted manually from medical records. Data acquisition included patient demographics, knee range of motion, and patient-reported outcomes via KSS, KOOS, WOMAC, and SF-12 scores. RESULTS A total of 38 patients were randomized to the PS group and 39 to the BCR group. At the 5-year follow-up, no statistical differences were noted for knee range of motion or patient-reported outcomes between the two groups, except for a greater knee flexion in the early follow-up period in the PS group. Five adverse events occurred in the BCR group compared to none in the PS group (p = 0.02). CONCLUSION BCR TKA yield similar clinical and patient-reported outcomes 5 years following the intervention compared with PS TKA. The BCR TKA had more complications. LEVEL OF EVIDENCE I (Randomized Controlled Trial).
Collapse
|
6
|
Prospective sequential comparison of femoral roll-back between cruciate-retaining and posterior-stabilized total knee arthroplasty using an intra-operative sensor. Knee 2022; 39:253-260. [PMID: 36283283 DOI: 10.1016/j.knee.2022.09.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 08/06/2022] [Accepted: 09/21/2022] [Indexed: 11/07/2022]
Abstract
BACKGROUND Implant design and surgical techniques affect postoperative knee kinematics in total knee arthroplasty (TKA). This study aimed to compare femoral roll-back between cruciate-retaining (CR) and posterior-stabilized (PS) TKA in the same knee by objectively quantifying the contact point kinematics of the tibiofemoral joint using a sensor. METHODS In the present prospective study, we used an intraoperative sensor to compare medial and lateral roll-back during 0-120° knee flexion in 33 knees that underwent CR and PS TKA. We also examined the relationship between mediolateral balance and the lateral-to-medial roll-back ratio. We defined the contact percentage position as the vertical length to the contact point divided by the anteroposterior length of the tibial plate. RESULTS The roll-back percentage following PS TKA (19.8 ± 5.1%) was significantly higher than that after CR TKA in both the medial (19.8 ± 5.1% versus 7.1 ± 2.5%, P < 0.001) and lateral (26.8% ± 3.8% versus 18.7 ± 3.8%, P < 0.001) compartments. The medial contact pressure at 90° was significantly correlated with the increased lateral-to-medial roll-back ratio in both CR and PS TKA (both P < 0.001). CONCLUSION PS TKA resulted in a higher percentage of femoral roll-back in the medial and lateral compartments than CR TKA. CR TKA caused a higher lateral-to-medial roll-back ratio compared to PS TKA. To reproduce medial pivot knee motion similar to that of a normal knee, the medial soft tissue needed to be balanced more tightly than the lateral soft tissue during TKA. These findings provide some clinical evidence of TKA design selection and proper mediolateral balancing for successful TKA.
Collapse
|
7
|
High rate of tibial post-fracture in highly cross-linked polyethylene compared to conventional polyethylene in posterior-stabilized total knee arthroplasty at a minimum 12-year follow-up. Knee Surg Sports Traumatol Arthrosc 2022; 30:4072-4077. [PMID: 35129642 DOI: 10.1007/s00167-022-06901-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 01/16/2022] [Indexed: 10/19/2022]
Abstract
PURPOSE The purpose of this study was to assess tibial post-fracture between highly cross-linked polyethylene (HXPE) and conventional polyethylene inserts in consecutive posterior-stabilized (PS) total knee arthroplasty (TKA) over a minimum 12-year follow-up period. METHODS Between January 2007 and June 2008, a consecutive series of 2446 primary TKAs was performed in 1478 patients at a single institution. The final cohort was classified into two groups (1559 in the HXPE group and 887 in the conventional group) based on the insert material used during the procedure. RESULTS The mean follow-up period was 13.1 years in the HXPE group and 13.4 years in the conventional group. All 16 cases of tibial post-fracture occurred in the HXPE group. This complication rate was 1.03%. The mean elapsed time from primary TKA to the diagnosis of post-fracture was 3.9 years (range 0.5-10.0 years). Ten cases required replacement with a thicker polyethylene insert, and six cases underwent tibial revision surgery. There were no cases of tibial post-fracture in the conventional group. CONCLUSION Tibial post-fracture is not a rare complication in PS TKA with HXPE. Therefore, the possibility of a tibial post-fracture should be considered if newly developed pain, acute subluxation, effusion, patellar clunking, or instability occurs in patients treated with PS Scorpio knee system TKA using an HXPE insert. LEVEL OF EVIDENCE IV.
Collapse
|
8
|
Revision total knee arthroplasty for flexion instability : a concise follow-up of a previous report. Bone Joint J 2022; 104-B:1126-1131. [PMID: 36177638 DOI: 10.1302/0301-620x.104b10.bjj-2022-0358.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS We have previously reported the mid-term outcomes of revision total knee arthroplasty (TKA) for flexion instability. At a mean of four years, there were no re-revisions for instability. The aim of this study was to report the implant survivorship and clinical and radiological outcomes of the same cohort of of patients at a mean follow-up of ten years. METHODS The original publication included 60 revision TKAs in 60 patients which were undertaken between 2000 and 2010. The mean age of the patients at the time of revision TKA was 65 years, and 33 (55%) were female. Since that time, 21 patients died, leaving 39 patients (65%) available for analysis. The cumulative incidence of any re-revision with death as a competing risk was calculated. Knee Society Scores (KSSs) were also recorded, and updated radiographs were reviewed. RESULTS The cumulative incidence of any re-revision was 13% at a mean of ten years. At the most recent-follow-up, eight TKAs had been re-revised: three for recurrent flexion instability (two fully revised to varus-valgus constrained implants (VVCs), and one posterior-stabilized (PS) implant converted to VVC, one for global instability (PS to VVC), two for aseptic loosening of the femoral component, and two for periprosthetic joint infection). The ten-year cumulative incidence of any re-revision for instability was 7%. The median KSS improved significantly from 45 (interquartile range (IQR) 40 to 50) preoperatively to 70 (IQR 45 to 80) at a mean follow-up of ten years (p = 0.031). Radiologically, two patients, who had not undergone revision, had evidence of loosening (one tibial and one patellar). The remaining components were well fixed. CONCLUSION We found fair functional outcomes and implant survivorship at a mean of ten years after revision TKA for flexion instability with a PS implant. Recurrent instability and aseptic loosening were the most common indications for re-revision. Components with increased constraint, such as a VVC or hinged, should be used in these patients in order to reduce the risk of recurrent instability.Cite this article: Bone Joint J 2022;104-B(10):1126-1131.
Collapse
|
9
|
Increased posterior translation but similar clinical outcomes using ultracongruent instead of posterior stabilized total knee arthroplasties in a prospective randomized trial. Knee Surg Sports Traumatol Arthrosc 2022; 30:3041-3048. [PMID: 34436635 DOI: 10.1007/s00167-021-06710-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/14/2021] [Indexed: 12/22/2022]
Abstract
PURPOSE The aim of this study was to compare the posterior tibial translation after ultracongruent (UC) and posterior-stabilized (PS) total knee arthroplasty (TKA) with two different UC with different heights in the anterior lip, and two different PS designs. This study also aimed to compare the range of motion (ROM) and outcomes scores after the use of these TKA models. It was hypothesised less posterior tibial translation after PS than after UC TKA, and less posterior tibial translation with a higher anterior lip in the UC insert than with a lower one. METHODS It was designed as a prospective randomized study of a group of 120 patients operated with a cemented TKA. To clarify the main purpose of the study, four groups were analysed using different polyethylene designs: Triathlon PS insert in group one, Triathlon UC insert in group two, U2 PS insert in group three and U2 UC insert in group four. One year after surgery, a forced posterior drawer with a Telos Stress applying 15 kg of force posteriorly on the proximal tibia at 90° of knee flexion was analysed in the lateral radiograph. Limb alignment, tibial posterior slope and posterior condylar offset were also studied. RESULTS 30 patients were included in each group. The average age was 73 years. There were 72.2% female and 27.8% male patients. There were no significant differences in any demographic or radiographic studied variables, preoperative range of motion (ROM) or preoperative Knee Society Scores (KSS) among the different groups. One year after surgery, the average postoperative ROM and the postoperative KSS Knee and KSS Function scores improved in respect of the preoperative values in all the groups. There were no significant differences in the postoperative outcome scores among the different groups (p = n.s.). Postoperative alignment of the limb, tibial posterior slope and posterior condylar offset were similar in the 4 study groups (p = n.s.). The postoperative posterior tibial translation was different between groups: the PS groups (groups 1 and 3) showed significant inferior values (p < 0.001) in respect of the UC groups (groups 2 and 4). There were no differences between both groups of PS models, but there was a significant increase in the posterior tibial translation of the Triathlon UC insert (11.2 mm SD 3.2) in respect of the U2 UC insert (6.1 mm SD 4.5) (p = 0.004). CONCLUSIONS UC inserts restrict the posterior tibial translation after TKA less than PS inserts, but a design with a high anterior lip in the polyethylene UC insert can better control the posterior tibial translation than an insert with a small anterior lip. LEVEL OF EVIDENCE Level I. Randomised controlled trial.
Collapse
|
10
|
Restricted kinematic alignment may be associated with increased risk of aseptic loosening for posterior-stabilized TKA: a case-control study. Knee Surg Sports Traumatol Arthrosc 2022; 30:2838-2845. [PMID: 34424356 DOI: 10.1007/s00167-021-06714-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Accepted: 08/17/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE The purpose of the study was to compare clinical and radiological results between kinematic alignment (KA) and mechanical alignment (MA) with a posterior-stabilized (PS) total knee arthroplasty (TKA) with a post-cam mechanism at a minimum follow-up of 3 years. The authors hypothesized a higher risk of aseptic loosening when performing KA using PS TKA. METHODS A retrospective monocentric single surgeon case control study was performed comparing 100 matched patients who had TKA performed using a MA philosophy to 50 patients receiving TKA with a KA technique between January 2016 and October 2017. All patients had the same knee prosthesis (GMK primary posterior-stabilized, Medacta®, Switzerland). Patient specific cutting blocks were used in both groups and a restricted KA (rKA) was aimed in the KA group. A hybrid cementation technique was performed. The new Knee Society Score (KSS) and radiological assessment were collected preoperatively and at the final follow-up. Comparisons between groups were done with the T test or Fisher exact test. Global survival curves were estimated with Kaplan-Meier model. Significance was set at p < 0.05. RESULTS Mean follow-up was 42.9 months ± 3.6 (range 37.6-46.7) and 53.3 months ± 4.1 (range 45.5-59.8) for rKA and MA groups. Postoperatively, no significant differences were found for clinical scores between both groups. Radiological assessment found similar postoperative Hip-Knee-Ankle angle for rKA and MA groups (178° versus 179° respectively, NS). At last follow-up, a significant higher survivorship was found for the MA group compared to the rKA group (97 versus 84%; p < 0.001) for aseptic loosening revision as the endpoint. CONCLUSION An increased risk of tibial implant loosening was found with rKA compared to MA using a posterior-stabilized TKA with a post-cam system at short-term follow-up. Caution should be taken when choosing the TKA design while performing rKA. LEVEL OF EVIDENCE Retrospective case-control study, Level IV.
Collapse
|
11
|
When to Use a Condylar Constrained Insert in Non-Stemmed Posterior-Stabilized Total Knee Arthroplasty. Clin Orthop Surg 2020; 12:448-455. [PMID: 33274021 PMCID: PMC7683185 DOI: 10.4055/cios19169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 02/14/2020] [Indexed: 11/20/2022] Open
Abstract
Backgroud The constrained insert with non-stemmed tibial and femoral components can be used in the modern total knee arthroplasty (TKA) when soft-tissue balance and adequate stability from a posterior-stabilized (PS) insert cannot be achieved. This study aimed to identify the prevalence and predictive factors associated with the constrained insert use during primary TKA for varus deformity. Methods From August 2016 to March 2019, 554 primary TKAs were consecutively performed by one surgeon. The choice of using a conventional PS polyethylene insert versus a constrained insert was made by the surgeon, depending on the stability detected after an attempt to balance the soft tissue. The decision to convert to a constrained liner was made if the ligament could not be balanced, if flexion-extension gaps were mismatched, or if the varus-valgus opening was 3 mm or more when varus and valgus stress tests at 0° were applied. We retrospectively investigated the preoperative, intraoperative, and postoperative factors associated with the constrained insert use. Multiple logistic regression analysis was used to identify predictive factors of constrained insert use, and a receiver operating characteristic curve analysis was used to pinpoint a cutoff value of tibiofemoral varus angle. Results Constrained inserts were used in 130 of 497 varus knees (26.1%). A multivariate analysis revealed that the factors associated with an increased adjusted risk of constrained insert use included preoperative severe varus deformity (odds ratio [OR], 5.78; 95% confidence interval [CI], 2.75–12.16; p < 0.001) and severe release of soft tissue through the superficial medial collateral ligament (OR, 6.38; 95% CI, 2.94–13.85; p < 0.001). A preoperative anatomic tibiofemoral varus angle of > 19.8° was associated with the use of a constrained articulation with an area under the curve of 0.7 (95% CI, 0.4–0.8). Conclusions Prevalence of 26.1% for constrained insert use was found in this study. Preoperative anatomic tibiofemoral varus angle of > 19.8° and severe release of soft tissue through the superficial medial collateral ligament were associated with the use of a constrained articulation. The findings from this study will help surgeons to improve efficiency of surgical sequence planning and provide counseling to patients regarding the associated cost.
Collapse
|
12
|
No difference in patient preference for medial pivot versus posterior-stabilized design in staged bilateral total knee arthroplasty: a prospective study. Knee Surg Sports Traumatol Arthrosc 2020; 28:3805-3809. [PMID: 31993682 DOI: 10.1007/s00167-020-05867-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Accepted: 01/17/2020] [Indexed: 10/25/2022]
Abstract
PURPOSE Medial pivot (MP) TKA has been shown to mimic normal knee kinematics with long-term survivorship comparable to most contemporary TKA. However, there are inadequate evidences to suggest its superiority in terms of patient preference and satisfaction. The aim of this study is to compare the MP with posterior-stabilized (PS) TKA in terms of patient preference and satisfaction. METHODS 46 patients with staged bilateral TKA were recruited. TKA with MP or PS design was performed at interval of 6-12 months. Patient preference, patient satisfaction score (0-100), Forgotten Joint Score (FJS), range of motion (ROM), Pain Score, Knee Society Score (KSS), Knee Function Score (KFS) and WOMAC Score were compared at up to 12 months. RESULTS The mean age was 70 and 69.6% were female. There was no difference in all preoperative parameters, operative time and length of stay between two knees. No difference was found in in range of motion and all outcome scores at 6 months and 12 months. Satisfaction score was similar for the two designs (82 vs 85, p = n.s.) at 1 year after the second TKA. Proportion of patients with preference on one design over another was not significantly different (28.9 vs 35.6%, p = n.s.). CONCLUSIONS There is no evidence to support the superiority of MP TKA over PS TKA in terms of preference and satisfaction. The choice between MP TKA versus PS TKA maybe more a surgeon's preference than a patient's preference based on current evidence.
Collapse
|
13
|
Intraoperative soft tissue balance using novel medial preserving gap technique in posterior-stabilized total knee arthroplasty: comparison to measured resection technique. Knee Surg Sports Traumatol Arthrosc 2018; 26:3474-3481. [PMID: 29680905 DOI: 10.1007/s00167-018-4945-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Accepted: 04/18/2018] [Indexed: 11/28/2022]
Abstract
PURPOSE To investigate intraoperative soft tissue balance with femoral component trial in place using a novel medial preserving gap technique, focusing on medial compartment stability and allowing lateral physiological laxity, with compared with using a measured resection technique in posterior-stabilized (PS) total knee arthroplasty (TKA). METHODS Primary PS TKA, using either medial preserving gap technique (n = 127) or measured resection technique (n = 148), was performed in 275 subjects with varus knee osteoarthritis. Intraoperative soft tissue balance with femoral component in place was assessed using Offset Repo-Tensor with 40 lbs. of joint distraction force throughout the range of motion, and medial and lateral compartment gaps (mm) were calculated. Medial and lateral joint gap changes (mm) were calculated by subtracting the medial/lateral compartment gap at 0° from the medial/lateral compartment gap at each knee flexion angle, respectively. RESULTS Medial and lateral joint gap changes in medial preserving gap technique were significantly smaller than measured resection technique respectively (mean difference between two procedures: medial; 0.9 ± 0.2 mm, lateral; 1.0 ± 0.3 mm). Medial and lateral joint gaps were significantly changed during knee flexion in measured resection technique, whereas medial and lateral joint gaps were not significantly changed during mid-to-deep knee flexion (30°-90° in medial, 30°-120° in lateral) in medial preserving gap technique. CONCLUSIONS Medial preserving gap technique provided more consistent intraoperative soft tissue balance during knee flexion than the measured resection technique, suggesting that this novel technique can be utilized to obtain a more stable joint gap in PS TKA. LEVEL OF EVIDENCE III.
Collapse
|
14
|
Assessment of the midflexion rotational laxity in posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2017; 25:3495-3500. [PMID: 27246993 DOI: 10.1007/s00167-016-4175-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Accepted: 05/17/2016] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate changes in midflexion rotational laxity before and after posterior-stabilized (PS)-total knee arthroplasty (TKA). METHODS Twenty-nine knees that underwent PS-TKA were evaluated. Manual mild passive rotational stress was applied to the knees, and the internal-external rotational angle was measured automatically by a navigation system at 30°, 45°, 60°, and 90° of knee flexion. RESULTS The post-operative internal rotational laxity was statistically significantly increased compared to the preoperative level at 30°, 45°, 60°, and 90° of flexion. The post-operative external rotational laxity was statistically significantly decreased compared to the preoperative level at 45° and 60° of flexion. The post-operative internal-external rotational laxity was statistically significantly increased compared to the preoperative level only at 30° of flexion. The preoperative and post-operative rotational laxity showed a significant correlation at 30°, 45°, 60°, and 90° of flexion. CONCLUSION Internal-external rotational laxity increases at the initial flexion range due to resection of both the anterior or posterior cruciate ligaments and retention of the collateral ligaments in PS-TKA. Preoperative and post-operative rotational laxity indicated a significant correlation at the midflexion range. This study showed that a large preoperative rotational laxity increased the risk of a large post-operative laxity, especially at the initial flexion range in PS-TKA. LEVEL OF EVIDENCE III.
Collapse
|
15
|
Posterior-stabilized total knee arthroplasty: a matched pair analysis of a classic and its evolutional design. Arthroplast Today 2016; 2:193-198. [PMID: 28326427 PMCID: PMC5247512 DOI: 10.1016/j.artd.2016.05.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2015] [Revised: 05/09/2016] [Accepted: 05/10/2016] [Indexed: 11/23/2022] Open
Abstract
Background Total knee arthroplasty (TKA) designs continue to be modified to optimize patient's outcome. This study was designed to compare clinical and radiological results of classic worldwide used TKA posterior-stabilized (PS) design to those of its recent evolution. Methods A consecutive group of 100 patients undergoing TKA using a classic cemented fixed-bearing PS TKA system was matched by age, gender, body max index to 100 patients having the newer cemented fixed-bearing PS design, both by the same manufacturer. Patients were assessed preoperatively, at 12 months and at 24 months minimum follow-up (range, 24-46) in a standard prospective fashion. The outcome assessments used were the Oxford Knee Score, the Knee Society Score, range of motion, and a satisfaction survey. A 2-sample t test comparing the 2 groups was performed. Results No patients were lost at follow-up. At 2-year follow-up, differences in clinical and radiological Knee Society Score (P = .09), Oxford Score (P = .08), and overall satisfaction rate did not reach statistical significance. Implant group 2 showed a statistically significant decrease in postoperative anterior knee pain (P = .006). At final follow-up, 16% of group 1 knees achieved > 130° flexion compared with 37% in group 2 (P = .0009). There were 2 revisions for any reason in group 1 and none in group 2. Conclusions Design modifications applied to the newer TKA system allowed greater flexion and lower patellofemoral complications but did not appear to achieve better overall clinical scores.
Collapse
|
16
|
In-vivo kinematics of high-flex posterior-stabilized total knee prosthesis designed for Asian populations. INTERNATIONAL ORTHOPAEDICS 2016; 40:2295-2302. [PMID: 27038027 DOI: 10.1007/s00264-016-3176-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2015] [Accepted: 03/16/2016] [Indexed: 10/22/2022]
Abstract
PURPOSE The purpose of this study was to determine in-vivo kinematics of our developed posterior-stabilized (PS) total knee prosthesis for Asian populations in comparison with a popular high-flexion PS prosthesis. METHODS We analyzed 62 osteoarthritic knees: 31 knees with the new PS prosthesis (group A) and 31 knees with a popular high-flexion PS prosthesis (group B). Radiographic knee images were taken during standing, lunge, and kneeling activities. The three-dimensional position and orientation of the implant components were determined using model-based shape matching techniques. RESULTS Group A showed slightly greater implant flexion angles compared with knees with conventional prosthesis at maximum lunge (average: 119 vs. 110°, p = 0.001), and at maximum kneeling (121 vs. 114°, p = 0.004), although the range of motion was not significantly different. The femoral centre positions were more posterior in group A at standing, at 90° lunge, at maximum lunge (-9 and -7 mm, p = 0.004), at 90° kneeling, and at maximum kneeling (-9 vs. -7 mm, p = 0.016), and posterior translations of the femoral center were greater at 90° knee flexion postures. The femoral centre positions had a strong negative correlation with implant flexion angles at maximum lunge in group B (r = -0.893, p < 0.001), but not in group A (p = 0.242). CONCLUSIONS The new PS prosthesis designed for Asian knee morphology achieved flexion angles and range of motion at least comparable to that of conventional high-flexion PS prosthesis. The femoral roll-back pattern, however, is different from a conventional knee, reflecting the post/cam design.
Collapse
|
17
|
Intraoperative joint gaps and mediolateral balance affect postoperative knee kinematics in posterior-stabilized total knee arthroplasty. Knee 2015; 22:527-34. [PMID: 26014342 DOI: 10.1016/j.knee.2015.03.006] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2014] [Revised: 01/22/2015] [Accepted: 03/17/2015] [Indexed: 02/02/2023]
Abstract
BACKGROUND Adjusting joint gaps and establishing mediolateral (ML) soft tissue balance are considered essential interventions for better outcomes in total knee arthroplasty (TKA). However, the relationship between intraoperative laxity measurements and weightbearing knee kinematics has not been well explored. This study aimed to quantify the effect of intraoperative joint gaps and ML soft tissue balance on postoperative knee kinematics in posterior-stabilized (PS)-TKA. METHODS We investigated 44 knees in 34 patients who underwent primary PS-TKA by a single surgeon. The central joint gaps and ML tilting angles at 0°, 10°, 30°, 60°, 90°, 120° and 135° flexion were measured during surgery. At a minimum of two year follow-up, we analyzed in vivo kinematics of these knees and examined the influence of intraoperative measurements on postoperative kinematics. RESULTS Gap difference of knee flexion at 135° minus 0° was correlated with the total posterior translation of lateral femoral condyle (r=0.336, p=0.042) and femoral external rotation (r=0.488, p=0.002) during squatting, anteroposterior position of lateral femoral condyle (r=-0.510, p=0.001) and maximum knee flexion (r=0.355, p=0.031) in kneeling. Similar correlations were observed between deep flexion gap differences with respect to the 90° reference and postoperative knee kinematics. Well-balanced knees showed less anterior translation of medial femoral condyle in mid- to deep flexion, consistent femoral external rotation, and the most neutral valgus/varus rotation compared with unbalanced knees. CONCLUSION These findings indicate the importance of adequate intraoperative joint gaps in deep flexion and ML soft tissue balance throughout the range of motion.
Collapse
|
18
|
180° rotatory dislocation of the rotating platform of a posterior-stabilized mobile-bearing knee prosthesis; possible complication after closed reduction of a posterior dislocation--a case report. Knee 2014; 21:322-4. [PMID: 23088890 DOI: 10.1016/j.knee.2012.09.016] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2012] [Revised: 08/21/2012] [Accepted: 09/22/2012] [Indexed: 02/02/2023]
Abstract
Dislocation of the rotating platform is a significant early complication of mobile-bearing total knee arthroplasty. The authors report an unusual case of acute 180° rotatory dislocation of the rotating platform after closed reduction of a posterior dislocation of a posterior-stabilized mobile-bearing total knee prosthesis. A 71-year-old male with knee osteoarthritis underwent TKRA using a posterior-stabilized mobile-bearing prosthesis. Posterior dislocation of the prosthesis occurred at 5 weeks postoperatively, and closed reduction of the posterior dislocation resulted in complete 180° rotatory dislocation of the rotating platform. The patient was treated by open exploration and polyethylene exchange for a larger component. This case illustrates that dislocation of a posterior-stabilized mobile-bearing total knee prosthesis can occur given valgus laxity and causes a 90° spin-out of the polyethylene insert, and that closed reduction attempts may contribute to complete 180° rotatory dislocation of the rotating platform. Special attention should be given to both AP and lateral views to ensure that the platform is truly reduced and not rotated by 180°. Plain digital radiography, which enhances the density of polyethylene, or arthrography is helpful for diagnosing this complication.
Collapse
|
19
|
Fracture of a polyethylene tibial post in a Scorpio posterior-stabilized knee prosthesis. Clin Orthop Surg 2009; 1:118-21. [PMID: 19885065 PMCID: PMC2766758 DOI: 10.4055/cios.2009.1.2.118] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2008] [Accepted: 08/19/2008] [Indexed: 11/06/2022] Open
Abstract
We report the case of a polyethylene tibial post fracture in a 72-year-old woman 14 months after a Scorpio posterior-stabilized (PS) total knee arthroplasty. The polyethylene wear was found around the fracture site of the post, especially over the anterior aspect of the post base. The failure mechanism of the post fracture in the present case was anterior impingement with excessive wear over the base of the anterior aspect of the tibial post, which became a stress-riser of post and cam articulation. This is the first report of a polyethylene tibial post fracture of a Scorpio PS prosthesis.
Collapse
|