1
|
Cilostazol promotes blood vessel formation and bone regeneration in a murine non-union model. Biomed Pharmacother 2023; 168:115697. [PMID: 37864892 DOI: 10.1016/j.biopha.2023.115697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 10/06/2023] [Accepted: 10/09/2023] [Indexed: 10/23/2023] Open
Abstract
Non-unions represent a major complication in trauma and orthopedic surgery. Many factors contribute to bone regeneration, out of which an adequate vascularization has been recognized as crucial. The phosphodiesterase-3 (PDE-3) inhibitor cilostazol has been shown to exert pro-angiogenic and pro-osteogenic effects in a variety of preclinical studies. Hence, we herein investigated the effects of cilostazol on bone regeneration in an atrophic non-union model in mice. For this purpose, a 1.8 mm femoral segmental defect was stabilized by pin-clip fixation and the animals were treated daily with 30 mg/kg body weight cilostazol or saline (control) per os. At 2, 5 and 10 weeks after surgery the healing of femora was analyzed by X-ray, biomechanics, photoacoustic imaging, and micro-computed tomography (µCT). To investigate the cellular composition and the growth factor expression of the callus tissue additional histological, immunohistochemical and Western blot analyses were performed. Cilostazol-treated animals showed increased bone formation within the callus, resulting in an enhanced bending stiffness when compared to controls. This was associated with a more pronounced expression of vascular endothelial growth factor (VEGF), a higher number of CD31-positive microvessels and an increased oxygen saturation within the callus tissue. Furthermore, cilostazol induced higher numbers of tartrate-resistant acidic phosphate (TRAP)-positive osteoclasts and CD68-positive macrophages. Taken together, these findings demonstrate that cilostazol is a promising drug candidate for the adjuvant treatment of atrophic non-unions in clinical practice.
Collapse
|
2
|
Parathyroid hormone stimulates bone regeneration in an atrophic non-union model in aged mice. J Transl Med 2023; 21:844. [PMID: 37996876 PMCID: PMC10668449 DOI: 10.1186/s12967-023-04661-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 10/26/2023] [Indexed: 11/25/2023] Open
Abstract
BACKGROUND Non-union formation still represents a major burden in trauma and orthopedic surgery. Moreover, aged patients are at an increased risk for bone healing failure. Parathyroid hormone (PTH) has been shown to accelerate fracture healing in young adult animals. However, there is no information whether PTH also stimulates bone regeneration in atrophic non-unions in the aged. Therefore, the aim of the present study was to analyze the effect of PTH on bone regeneration in an atrophic non-union model in aged CD-1 mice. METHODS After creation of a 1.8 mm segmental defect, mice femora were stabilized by pin-clip fixation. The animals were treated daily with either 200 mg/kg body weight PTH 1-34 (n = 17) or saline (control; n = 17) subcutaneously. Bone regeneration was analyzed by means of X-ray, biomechanics, micro-computed tomography (µCT) imaging as well as histological, immunohistochemical and Western blot analyses. RESULTS In PTH-treated animals bone formation was markedly improved when compared to controls. This was associated with an increased bending stiffness as well as a higher number of tartrate-resistant acid phosphatase (TRAP)-positive osteoclasts and CD31-positive microvessels within the callus tissue. Furthermore, PTH-treated aged animals showed a decreased inflammatory response, characterized by a lower number of MPO-positive granulocytes and CD68-positive macrophages within the bone defects when compared to controls. Additional Western blot analyses demonstrated a significantly higher expression of cyclooxygenase (COX)-2 and phosphoinositide 3-kinase (PI3K) in PTH-treated mice. CONCLUSION Taken together, these findings indicate that PTH is an effective pharmacological compound for the treatment of non-union formation in aged animals.
Collapse
|
3
|
Sildenafil, a phosphodiesterase-5 inhibitor, stimulates angiogenesis and bone regeneration in an atrophic non-union model in mice. J Transl Med 2023; 21:607. [PMID: 37684656 PMCID: PMC10486066 DOI: 10.1186/s12967-023-04441-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 08/14/2023] [Indexed: 09/10/2023] Open
Abstract
Non-union formation represents a major complication in trauma and orthopedic surgery. The phosphodiesterase-5 (PDE-5) inhibitor sildenafil has been shown to exert pro-angiogenic and pro-osteogenic effects in vitro and in vivo. Therefore, the aim of the present study was to analyze the impact of sildenafil in an atrophic non-union model in mice. After creation of a 1.8 mm segmental defect, mice femora were stabilized by pin-clip fixation. Bone regeneration was analyzed by means of X-ray, biomechanics, photoacoustic and micro-computed tomography (µCT) imaging as well as histological, immunohistochemical and Western blot analyses at 2, 5 and 10 weeks after surgery. The animals were treated daily with either 5 mg/kg body weight sildenafil (n = 35) or saline (control; n = 35) per os. Bone formation was markedly improved in defects of sildenafil-treated mice when compared to controls. This was associated with a higher bending stiffness as well as an increased number of CD31-positive microvessels and a higher oxygen saturation within the callus tissue. Moreover, the bone defects of sildenafil-treated animals contained more tartrate-resistant acid phosphatase (TRAP)-positive osteoclasts and CD68-positive macrophages and exhibited a higher expression of the pro-angiogenic and pro-osteogenic markers cysteine rich protein (CYR)61 and vascular endothelial growth factor (VEGF) when compared to controls. These findings demonstrate that sildenafil acts as a potent stimulator of angiogenesis and bone regeneration in atrophic non-unions.
Collapse
|
4
|
Comparison of two non-union models with damaged periosteum in mice: Segmental defect and pin-clip fixation versus transverse fracture and K-wire stabilization. Bone 2022; 162:116475. [PMID: 35752408 DOI: 10.1016/j.bone.2022.116475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Revised: 06/08/2022] [Accepted: 06/17/2022] [Indexed: 11/02/2022]
Abstract
Despite growing knowledge about the mechanisms of fracture healing, non-union formation still represents a major complication in trauma and orthopedic surgery. Non-union models in mice gain increasing interest, because they allow investigating the molecular and cellular mechanisms of failed fracture healing. These models often use segmental defects to achieve non-union formation. Alternatively, failed fracture healing can be induced by transverse fractures with additional periosteal injury. The present study systematically compared the reliability of these two approaches to serve as non-union model. A 0.6 mm K-wire was inserted into the femora of CD-1 mice in a retrograde fashion and a closed transverse femoral fracture was created. Subsequently, the fracture site was exposed and the periosteum was cauterized. This approach was compared with a well-established non-union model involving the pin-clip fixation of a 1.8 mm segmental defect. The callus tissue was analyzed by means of radiography, biomechanics, histology and Western blotting. At 10 weeks after surgery 10 out of 12 femora (83.3 %) of the K-wire group showed a non-union formation. The pin-clip model resulted in 100 % non-union formation. The K-wire group showed increased bone formation, osteoclast activity and bending stiffness when compared to the group with pin-clip fixation. This was associated with a higher expression of bone formation markers. However, the number of CD31-positive microvessels was reduced in the K-wire group, indicating an impaired angiogenic capacity after periosteal cauterization. These findings suggest that the pin-clip model is more reliable for the study of non-union formation in mice. The K-wire model including periosteal injury by cauterization however, may be particularly applied in preclinical studies which explore the effects of damaged periosteum and reduced angiogenic capacity to trauma-induced fractures.
Collapse
|
5
|
Skeletal regeneration for segmental bone loss: Vascularised grafts, analogues and surrogates. Acta Biomater 2021; 136:37-55. [PMID: 34626818 DOI: 10.1016/j.actbio.2021.09.053] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 09/25/2021] [Accepted: 09/28/2021] [Indexed: 02/08/2023]
Abstract
Massive segmental bone defects (SBD) are mostly treated by removing the fibula and transplanting it complete with blood supply. While revolutionary 50 years ago, this remains the standard treatment. This review considers different strategies to repair SBD and emerging potential replacements for this highly invasive procedure. Prior to the technical breakthrough of microsurgery, researchers in the 1960s and 1970s had begun to make considerable progress in developing non autologous routes to repairing SBD. While the breaktthrough of vascularised bone transplantation solved the immediate problem of a lack of reliable repair strategies, much of their prior work is still relevant today. We challenge the assumption that mimicry is necessary or likely to be successful and instead point to the utility of quite crude (from a materials technology perspective), approaches. Together there are quite compelling indications that the body can regenerate entire bone segments with few or no exogenous factors. This is important, as there is a limit to how expensive a bone repair can be and still be widely available to all patients since cost restraints within healthcare systems are not likely to diminish in the near future. STATEMENT OF SIGNIFICANCE: This review is significant because it is a multidisciplinary view of several surgeons and scientists as to what is driving improvement in segmental bone defect repair, why many approaches to date have not succeeded and why some quite basic approaches can be as effective as they are. While there are many reviews of the literature of grafting and bone repair the relative lack of substantial improvement and slow rate of progress in clinical translation is often overlooked and we seek to challenge the reader to consider the issue more broadly.
Collapse
|
6
|
Abstract
Open fractures are associated with a higher rate of infections and delayed fracture healing; therefore, in addition to fracture fixation, infection prevention and soft tissue management are also important. Administration of antibiotics should be carried out as early as possible and over 24-72 h depending on the injury. The initial debridement and assessment of the severity of injury determine the treatment strategy. Fracture fixation follows the general traumatological principles. Simple injury patterns can be treated by primary fixation and wound closure. With substantial contamination, loss of bone or extensive soft tissue damage, temporary fixation and temporary wound closure are carried out. The definitive treatment with soft tissue coverage should be performed within 72 h in order to reduce the risk of fracture-related infections. For osseous segmental defects, different approaches are available to restore bone continuity, depending on the size and soft tissue situation.
Collapse
|
7
|
The effect of different coatings on bone response and degradation behavior of porous magnesium-strontium devices in segmental defect regeneration. Bioact Mater 2021; 6:1765-1776. [PMID: 33313453 PMCID: PMC7718143 DOI: 10.1016/j.bioactmat.2020.11.026] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 11/10/2020] [Accepted: 11/17/2020] [Indexed: 12/12/2022] Open
Abstract
Regeneration of long-bone segmental defects remains a challenge for orthopedic surgery. Current treatment options often require several revision procedures to maintain acceptable alignment and achieve osseous healing. A novel hollow tubular system utilizing magnesium-strontium (Mg-Sr) alloy with autogenous morselized bone filled inside to repair segmental defects was developed. To improve the corrosion and biocompatible properties, two coatings, Ca-P and Sr-P coatings, were prepared on surface of the implants. Feasibility of applying these coated implants was systematically evaluated in vitro and in vivo, and simultaneously to have a better understanding on the relationship of degradation and bone regeneration on the healing process. According to the in vitro corrosion study by electrochemical measurements, greater corrosion resistance was obtained for Ca-P coated sample, and attributed to the double-layer protective structure. The cytotoxicity and alkaline phosphatase (ALP) assays demonstrated enhanced bioactivity for Sr-P coated group because of the long-lasting release of beneficial Sr2+. At 12 weeks post-implantation with Mg-Sr alloy porous device, the segmental defects were effectively repaired with respect to both integrity and continuity. In addition, compared with the Ca-P coated implant, the Sr-P coated implant was more proficient at promoting bone formation and mineralization. In summary, the Sr-P coated implants have bioactive properties and exceptional durability, and promote bone healing that is close to the natural rate, implying their potential application for the regeneration of segmental defects.
Collapse
|
8
|
A novel autologous bone graft substitute containing rhBMP6 in autologous blood coagulum with synthetic ceramics for reconstruction of a large humerus segmental gunshot defect in a dog: The first veterinary patient to receive a novel osteoinductive therapy. Bone Rep 2021; 14:100759. [PMID: 33732816 PMCID: PMC7937538 DOI: 10.1016/j.bonr.2021.100759] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 02/01/2021] [Accepted: 02/22/2021] [Indexed: 12/20/2022] Open
Abstract
Background Management of large segmental defects is one of the most challenging issues in bone repair biology. Autologous bone graft substitute (ABGS) containing rhBMP6 within autologous blood coagulum (ABC) with synthetic ceramics is a novel biocompatible therapeutic solution for bone regeneration. Case presentation A 2-year old dog was brought to the veterinary clinics due to pain and bleeding from the right front leg after being unintendedly hit by a gunshot. Radiological examination revealed a large, 3 cm long multisegmental defect of the humerus on the right front leg with a loss of anatomical structure in the distal portion of the bone. The defect was treated surgically and an external fixator was inserted to ensure immobilization. Complete lack of bone formation 3 months following surgery required a full reconstruction of the defect site with a novel ABGS (rhBMP6 in ABC with ceramic particles) to avoid front leg amputation. The healing was then followed for the next 16 months. The callus formation was observed on x-ray images 2 months following ABGS implantation. The bone segments progressively fused together leading to the defect rebridgment allowing removal of the external fixator by 4 months after the reconstruction surgery. At the end of the observation period, the function of the leg was almost fully restored while analyses of the humeral CT sections revealed restoration and cortices rebridgment with a renewal of uniform medullary canal including structural reconstruction of the distal humerus. Conclusion This large humeral gunshot segmental defect of the front leg in a dog was saved from amputation via inducing bone regeneration using a novel ABGS osteoinductive device containing BMP6 in ABC.
Collapse
|
9
|
Guided bone regeneration with osteoconductive grafts and PDGF: A tissue engineering option for segmental bone defect reconstruction. J Appl Biomater Funct Mater 2021; 19:2280800020987405. [PMID: 33541198 DOI: 10.1177/2280800020987405] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Regeneration and reconstruction of segmental bone defects (SBD) is a clinical challenge in maxillofacial surgery and orthopedics. The present study evaluated efficacy of guided bone-regeneration (GBR) of rat femoral SBD using osteoconductive equine-bone (EB) and beta-tricalcium phosphate (beta-TCP) grafts, either with or without platelet-derived growth-factor (PDGF). Following ethical-approval, 50 male Wistar-Albino rats (aged ~12-15 months and weighing ~450-500 g) were included. A 5 mm femoral critical-size SBD was created and animals were divided into five groups depending on the graft material used for GBR (EB, EB + PDGF, Autograft, beta-TCP, beta-TCP + PDGF; n = 10/group). Following 12-weeks of healing, animals were sacrificed and femur specimens were analyzed through qualitative histology and quantitative histomorphometry. There was new bone bridging femoral SBD in all groups and qualitatively, better bone formation was seen in autograft and EB + PDGF groups. Histomorphometric bone-area (BA %) was significantly high in autograft group, followed by EB + PDGF, beta-TCP + PDGF, EB, and beta-TCP groups. Addition of PDGF to EB and beta-TCP during GBR resulted in significantly higher BA%. After 12-weeks of healing, EB + PDGF for GBR of rat femoral segmental defects resulted in new bone formation similar to that of autograft. Based on this study, GBR with EB and adjunct PDGF could be a potential clinical alternative for reconstruction and regeneration of segmental bone defects.
Collapse
|
10
|
Abstract
Complications related to treatment of long bone fractures still stand as a major challenge for orthopaedic surgeons. Elucidation of the mechanisms of bone healing and development, and the subsequent alteration of these mechanisms to improve outcomes, typically requires animal models as an intermediary between in vitro and human clinical studies. Murine models are some of the most commonly used in translational research, and mouse fracture models are particularly diverse, offering a wide variety of customization with distinct benefits and limitations depending on the study. This review critically examines three common femur fracture models in the mouse, namely cortical hole, 3-point fracture (Einhorn), and segmental bone defect. We lay out the general procedure for execution of each model, evaluate the practical implications and important advantages/disadvantages of each and describe recent innovations. Furthermore, we explore the applications that each model is best adapted for in the context of the current state of murine orthopaedic research.
Collapse
|
11
|
Biomechanical evaluation of peak reverse torque (PRT) in a dynamic compression plate-screw construct used in a goat tibia segmental defect model. BMC Vet Res 2019; 15:321. [PMID: 31488151 PMCID: PMC6729065 DOI: 10.1186/s12917-019-2058-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Accepted: 08/21/2019] [Indexed: 12/20/2022] Open
Abstract
Background Peak reverse torque (PRT) is a valid method to evaluate implants’ secondary stability in the healing bone. The secondary stability is achieved by the implant over time and it has been positively correlated with the implants’ osseointegration level. In other words, peak reverse torque is the force required to break the bone-implant interface. The purpose of this study was to compare the peak reverse torque for the self-tapping and non-self-tapping screws used in a dynamic compression plate–screw–bone construct after 60 days of loading when used to stabilize 2.5-cm defects in the tibia of goats. The second objective was to compare the peak removal torque of the screws placed in the different positions to evaluate the impact of construct biomechanics on implants osseointegration. Results In total, 176 non-self-tapping screws and 66 self-tapping screws were used to fix the 8-holes dynamic compression plates to the bones. The screws were placed in the tibiae from proximal (position sites 1,2, 3) to distal (position sites 4,5,6) and were removed 60 days post-implantation. The animals remained weight-bearing throughout the study period. The screws placed in the proximal diaphysis had significantly less peak reverse torque than screws placed in the distal diaphysis in both groups (p < 0.05). The peak reverse torque resistance was also significantly less for the non-self-tapping screws as compared with the self-tapping screws (p < 0.05). The intracortical fractures in the trans-cortex occurred significantly more frequently during the placement of non-self-tapping screws (p < 0.05) as compared with self-tapping screws (p < 0.05). Conclusions Based on these results, we concluded that self-tapping screws may be expected to maintain a more stable bone-implant interface during the first 60 days of loading as compared with non-self-tapping screws. This should be a consideration for orthopedic surgeons and scientists using bone plates to stabilize non-load sharing fractures when a stable plate-screw-bone interface is needed to ensure prolonged stability.
Collapse
|
12
|
Bone regeneration of hollow tubular magnesium‑strontium scaffolds in critical-size segmental defects: Effect of surface coatings. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 100:297-307. [PMID: 30948064 DOI: 10.1016/j.msec.2019.02.067] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 01/18/2019] [Accepted: 02/16/2019] [Indexed: 12/20/2022]
Abstract
Segmental defects are formidable challenges for orthopedic surgeons that are caused by large osseous defects such as open injury, comminuted fracture as well as other severe traumas and infection. Current treatment options have practical and clinical shortcomings, calling for innovative bone graft materials. This study is related to hollow tubular magnesium‑strontium (MgSr) alloy scaffolds with autologous morselized bone filled inside and three different coatings were individually applied on MgSr scaffolds, respectively, to study the effects of degradation and bioactivity of the grafts on new bone growth. The optimal coating method was screened using immersion tests, cell proliferation and adhesion, alkaline phosphatase (ALP) assay in vitro, and 4 weeks' implantation in a critical-size segmental defect in vivo. More new bone formation was observed by radiographic tests and histology along the ulna defects, when magnesium scaffold grafts were implanted. Meanwhile, depression occurred for blank control group with only autologous morselized bone filled, because of rapid absorption rate of morselized bone during initial implantation. Therefore, biodegradable MgSr alloy grafts showed their potential application in treating the critical-size segmental defects. As for different coating methods, CaP chemically deposited (CaP) coated sample showed least H2 evolution in vivo, demonstrating highest corrosion resistance and relative stable interfaces, however, the least beneficial ion release meanwhile. Micro-arc oxidation coating (MAO) degraded faster comparing with CaP, while with the main composition of MgO. They both indicate insufficient bioactivity in bone formation. The results suggest superior combination of bioactive surface, beneficial ions release and appropriate corrosion rate of Strontium phosphate conversion (SrP) coating, indicating superior comprehensive oeteoconductive and osteoinductive properties of coatings on hollow tubular MgSr alloy scaffold.
Collapse
|
13
|
The use of vascularized fibula flap in mandibular reconstruction; A comprehensive systematic review and meta-analysis of the observational studies. J Craniomaxillofac Surg 2019; 47:629-641. [PMID: 30782453 DOI: 10.1016/j.jcms.2019.01.037] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 12/11/2018] [Accepted: 01/25/2019] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Vascularized fibular flaps are considered the gold standard for the reconstruction of segmental defects in the mandible. This review compares the complication and success rates of these techniques between primary and secondary reconstruction, as well as between lateral and antero-lateral defects. TYPE OF STUDIES REVIEWED A systematic review and meta-analysis were conducted according to PRISMA protocol and the Cochrane Handbook for Systematic Reviews of Interventions. The authors performed an independent comprehensive search using PubMed, Ovid MEDLINE, Web of Science, the Cochrane Central Register of Controlled Trials, ClinicalTrials.gov and COS Conference Papers Index according to established inclusion and exclusion criteria. The methodological index for nonrandomized studies (MINORS) was used to assess the quality of the included studies. Meta-analysis was conducted to compare the type of reconstruction and location of the defect. RESULTS Seventy-eight studies, involving 2461 patients, were eligible. 83.7% of the included patient received primary reconstruction with vascularized fibular flap. The overall flap success rate was 93%. There was improvement in MINORS quality score over time with positive correlation with the publication year (r = 0.5549, P < 0.0001, CI 0.3693 to 0.6979). Meta-analysis indicated no significant association in flap success between primary and secondary reconstruction, or lateral and antero-lateral defects. CONCLUSION Based on the available studies, this review found no evidence of difference in success or complication rates between primary and secondary reconstruction or between lateral and anterolateral defects. High-quality clinical studies are required to analyze the outcome of these techniques, especially regarding the impact of chemotherapy, radiation therapy, implant-supported dental prostheses, and preoperative planning, on the outcome of reconstruction.
Collapse
|
14
|
Bridging hard callus at 48 days in an open femoral shaft fracture with segmental defect treated with a first-stage Masquelet technique: I wasn't expecting that. Strategies Trauma Limb Reconstr 2017; 13:57-60. [PMID: 29116576 PMCID: PMC5862707 DOI: 10.1007/s11751-017-0300-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Accepted: 10/29/2017] [Indexed: 11/29/2022] Open
Abstract
The Masquelet technique is a strategy for management of segmental bone defects. It is a two-stage procedure that involves inducing a synovial-like membrane that can be used for a bone graft. Segmental bone defects can occur following trauma and can accompany traumatic brain injury. There is a well-documented, albeit debated, association between traumatic brain injury and increased rate of new bone formation. Here, we present a case of unexpected callus formation in a segmental femoral fracture. The patient had a traumatic brain injury and was treated with the first stage of the Masquelet technique. Owing to the amount of large callus, a second stage of the Masquelet was not required. The patient recovered well from the injury and at 16-week follow-up was able to partially weight bear. A case similar to this has not previously been reported within the literature.
Collapse
|
15
|
Delivery vehicle effects on bone regeneration and heterotopic ossification induced by high dose BMP-2. Acta Biomater 2017; 49:101-112. [PMID: 27940197 DOI: 10.1016/j.actbio.2016.12.012] [Citation(s) in RCA: 89] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Revised: 11/10/2016] [Accepted: 12/06/2016] [Indexed: 11/15/2022]
Abstract
Bone morphogenetic protein-2 (BMP-2), delivered on absorbable collagen sponge, is frequently used to treat bone defects. However, supraphysiological BMP-2 doses are common and often associated with complications such as heterotopic ossification and inflammation, causing pain and impaired mobility. This has prompted investigations into strategies to spatially control bone regeneration, for example growth factor delivery in appropriate scaffolds. Our objective was to investigate the spatiotemporal effects of high dose BMP-2 on bone regeneration as a function of the delivery vehicle. We hypothesized that an alginate delivery system would spatially restrict bone formation compared to a collagen sponge delivery system. In vitro, BMP-2 release was accelerated from collagen sponge compared to alginate constructs. In vivo, bone regeneration was evaluated over 12weeks in critically sized rat femoral segmental defects treated with 30μg rhBMP-2 in alginate hydrogel or collagen sponge, surrounded by perforated nanofiber meshes. Total bone volume, calculated from micro-CT reconstructions, was higher in the alginate group at 12weeks. Though bone volume within the central defect region was greater in the alginate group at 8 and 12weeks, heterotopic bone volume was similar between groups. Likewise, mechanical properties from ex vivo torsional testing were comparable between groups. Histology corroborated these findings and revealed heterotopic mineralization at 2weeks post-surgery in both groups. Overall, this study recapitulated the heterotopic ossification associated with high dose BMP-2 delivery, and demonstrated that the amount and spatial pattern of bone formation was dependent on the delivery matrix. STATEMENT OF SIGNIFICANCE Alginate hydrogel-based BMP-2 delivery has induced better spatiotemporal bone regeneration in animals, compared to clinically used collagen sponge, at lower BMP-2 doses. Lack of clear dose-response relationships for BMP-2 vis-à-vis bone regeneration has contributed to the use of higher doses clinically. We investigated the potential of the alginate system, with comparatively favorable BMP-2 release-kinetics, to reduce heterotopic ossification and promote bone regeneration, when used with a high BMP-2 dose. While defect mineralization improved with alginate hydrogel, the initial high-release phase and likely early tissue exposure to BMP-2 appeared sufficient to induce heterotopic ossification. The characterization presented here should provide the framework for future evaluations of strategies to optimize bone formation and minimize adverse effects of high dose BMP-2 therapy.
Collapse
|
16
|
Osteogenic, stem cell and molecular characterisation of the human induced membrane from extremity bone defects. Bone Joint Res 2016; 5:106-15. [PMID: 27056768 PMCID: PMC5009235 DOI: 10.1302/2046-3758.54.2000483] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2015] [Accepted: 02/25/2016] [Indexed: 01/08/2023] Open
Abstract
Objectives The biomembrane (induced membrane) formed around polymethylmethacrylate (PMMA) spacers has value in clinical applications for bone defect reconstruction. Few studies have evaluated its cellular, molecular or stem cell features. Our objective was to characterise induced membrane morphology, molecular features and osteogenic stem cell characteristics. Methods Following Institutional Review Board approval, biomembrane specimens were obtained from 12 patient surgeries for management of segmental bony defects (mean patient age 40.7 years, standard deviation 14.4). Biomembranes from nine tibias and three femurs were processed for morphologic, molecular or stem cell analyses. Gene expression was determined using the Affymetrix GeneChip Operating Software (GCOS). Molecular analyses compared biomembrane gene expression patterns with a mineralising osteoblast culture, and gene expression in specimens with longer spacer duration (> 12 weeks) with specimens with shorter durations. Statistical analyses used the unpaired student t-test (two tailed; p < 0.05 was considered significant). Results Average PMMA spacer in vivo time was 11.9 weeks (six to 18). Trabecular bone was present in 33.3% of the biomembrane specimens; bone presence did not correlate with spacer duration. Biomembrane morphology showed high vascularity and collagen content and positive staining for the key bone forming regulators, bone morphogenetic protein 2 (BMP2) and runt-related transcription factor 2 (RUNX2). Positive differentiation of cultured biomembrane cells for osteogenesis was found in cells from patients with PMMA present for six to 17 weeks. Stem cell differentiation showed greater variability in pluripotency for osteogenic potential (70.0%) compared with chondrogenic or adipogenic potentials (100% and 90.0%, respectively). Significant upregulation of BMP2 and 6, numerous collagens, and bone gla protein was present in biomembrane compared with the cultured cell line. Biomembranes with longer resident PMMA spacer duration (vs those with shorter residence) showed significant upregulation of bone-related, stem cell, and vascular-related genes. Conclusion The biomembrane technique is gaining favour in the management of complicated bone defects. Novel data on biological mechanisms provide improved understanding of the biomembrane’s osteogenic potential and molecular properties. Cite this article: Dr H. E. Gruber. Osteogenic, stem cell and molecular characterisation of the human induced membrane from extremity bone defects. Bone Joint Res 2016;5:106–115. DOI: 10.1302/2046-3758.54.2000483.
Collapse
|
17
|
Abstract
INTRODUCTION Clinical management of non-union of long bone fractures and segmental bone defect is a challenge for orthopaedic surgeons. The use of autologous bone graft (ABG) is always considered the gold standard treatment. Traditional techniques for harvesting ABG from iliac crest usually involve several complications, particularly at the donor site. The Reamer-Irrigator-Aspirator (RIA) is an intramedullary reaming system that generates a large volume of cancellous bone material in a single-step reaming process; this bone material can be collected and potentially used as an ABG source. Our interest is to compare the complications associated with the standard technique of harvesting from iliac crest with those of the innovative RIA harvesting device. MATERIALS AND METHODS A database of 70 patients with long bone non-unions was studied. The patients were divided into two groups according to the surgical harvesting technique used: RIA system ABG (35 patients) and iliac crest ABG (35 patients). RESULTS At the 12-month follow-up, pain at the donor site was reported in no patients in the RIA system ABG group and five of 35 patients (14.28%) in the iliac crest ABG group. Local infections at the donor site were found in no patients in the RIA system ABG group compared with five patients (14.28%) in the iliac crest ABG group. There were no fractures in the RIA system ABG group and one case (2.85%) of anterior superior iliac spine (ASIS) dislocation in the iliac crest ABG group. No systemic infections were detected in either group. DISCUSSION We analysed the scientific literature on the use of RIA technique to collect ABG for use in patients with anthropic-oligotrophic non-unions, with a focus on the complications associated with this technique. CONCLUSION RIA bone graft for the treatment of non-unions and segmental bone defect of long bones seems to be a safe and efficient procedure with low donor site morbidity.
Collapse
|