1
|
Black MI, Jones AM, Bailey SJ, Vanhatalo A. Self-pacing increases critical power and improves performance during severe-intensity exercise. Appl Physiol Nutr Metab 2015; 40:662-70. [PMID: 26088158 DOI: 10.1139/apnm-2014-0442] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The parameters of the power-duration relationship for severe-intensity exercise (i.e., the critical power (CP) and the curvature constant (W')) are related to the kinetics of pulmonary O2 uptake, which may be altered by pacing strategy. We tested the hypothesis that the CP would be higher when derived from a series of self-paced time-trials (TT) than when derived from the conventional series of constant work-rate (CWR) exercise tests. Ten male subjects (age, 21.5 ± 1.9 years; mass, 75.2 ± 11.5 kg) completed 3-4 CWR and 3-4 TT prediction trial protocols on a cycle ergometer for the determination of the CP and W'. The CP derived from the TT protocol (265 ± 44 W) was greater (P < 0.05) than the CP derived from the CWR protocol (250 ± 47 W), while the W' was not different between protocols (TT: 18.1 ± 5.7 kJ, CWR: 20.6 ± 7.4 kJ, P > 0.05). The mean response time of pulmonary O2 uptake was shorter during the TTs than the CWR trials (TT: 34 ± 16, CWR: 39 ± 19 s, P < 0.05). The CP was correlated with the total O2 consumed in the first 60 s across both protocols (r = 0.88, P < 0.05, n = 20). These results suggest that in comparison with the conventional CWR exercise protocol, a self-selected pacing strategy enhances CP and improves severe-intensity exercise performance. The greater CP during TT compared with CWR exercise has important implications for performance prediction, suggesting that TT completion times may be overestimated by CP and W' parameters derived from CWR protocols.
Collapse
|
Journal Article |
10 |
57 |
2
|
Chidnok W, Fulford J, Bailey SJ, Dimenna FJ, Skiba PF, Vanhatalo A, Jones AM. Muscle metabolic determinants of exercise tolerance following exhaustion: relationship to the "critical power". J Appl Physiol (1985) 2013; 115:243-50. [PMID: 23640601 DOI: 10.1152/japplphysiol.00334.2013] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
We tested the hypothesis that muscle high-energy phosphate compounds and metabolites related to the fatigue process would be recovered after exhaustion during recovery exercise performed below but not above critical power (CP) and that these changes would influence the capacity to continue exercise. Eight male subjects completed single-leg, knee-extension exercise to exhaustion (for ∼180 s) on three occasions, followed by a work-rate reduction to severe-intensity exercise, heavy-intensity exercise (<CP), or a 10-min passive recovery period, in random order. The muscle metabolic responses to exercise were assessed using (31)P magnetic resonance spectroscopy. There was a significant difference between the sustainable exercise duration during the recovery from exhaustive exercise between the <CP and >CP conditions (at least 10 min and 39 ± 31 s, respectively; P < 0.05). During passive recovery and <CP recovery exercise, muscle phosphocreatine concentration ([PCr]) increased rapidly after the exhaustion point, reaching ∼96% and ∼76% of baseline values, respectively, after 10 min (P < 0.05). Moreover, pH increased abruptly, reaching 7.0 ± 0.0 and 7.0 ± 0.2, respectively, after 10 min recovery (P < 0.05). However, during >CP recovery exercise, neither muscle [PCr] nor pH recovered, reaching ∼37% of the initial baseline and 6.6 ± 0.2, respectively. These results indicate that the muscle metabolic dynamics in recovery from exhaustive >CP differ according to whether the recovery exercise is performed below or above the CP. These findings confirm the importance of the CP as an intramuscular metabolic threshold that dictates the accumulation of fatigue-related metabolites and the capacity to tolerate high-intensity exercise.
Collapse
|
Research Support, Non-U.S. Gov't |
12 |
48 |
3
|
Felippe LC, Ferreira GA, Learsi SK, Boari D, Bertuzzi R, Lima-Silva AE. Caffeine increases both total work performed above critical power and peripheral fatigue during a 4-km cycling time trial. J Appl Physiol (1985) 2018; 124:1491-1501. [PMID: 29470151 DOI: 10.1152/japplphysiol.00930.2017] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The link between total work performed above critical power (CP) and peripheral muscle fatigue during self-paced exercise is unknown. We investigated the influence of caffeine on the total work done above CP during a 4-km cycling time trial (TT) and the subsequent consequence on the development of central and peripheral fatigue. Nine cyclists performed three constant-load exercise trials to determine CP and two 4-km TTs ~75 min after oral caffeine (5 mg/kg) or cellulose (placebo) ingestion. Neuromuscular functions were assessed before and 50 min after supplementation and 1 min after TT. Oral supplementation alone had no effect on neuromuscular function ( P > 0.05). Compared with placebo, caffeine increased mean power output (~4%, P = 0.01) and muscle recruitment (as inferred by EMG, ~17%, P = 0.01) and reduced the time to complete the TT (~2%, P = 0.01). Work performed above CP during the caffeine trial (16.7 ± 2.1 kJ) was significantly higher than during the placebo (14.7 ± 2.1 kJ, P = 0.01). End-exercise decline in quadriceps twitch force (pre- to postexercise decrease in twitch force at 1 and 10 Hz) was more pronounced after caffeine compared with placebo (121 ± 13 and 137 ± 14 N vs. 146 ± 13 and 156 ± 11 N; P < 0.05). There was no effect of caffeine on central fatigue. In conclusion, caffeine increases muscle recruitment, which enables greater work performed above CP and higher end-exercise peripheral locomotor muscle fatigue. NEW & NOTEWORTHY The link between total work done above critical power and peripheral fatigue during a self-paced, high-intensity exercise is unclear. This study revealed that caffeine ingestion increases muscle recruitment, which enables greater work done above critical power and a greater degree of end-exercise decline in quadriceps twitch force during a 4-km cycling time trial. These findings suggest that caffeine increases performance at the expense of greater locomotor muscle fatigue.
Collapse
|
Research Support, Non-U.S. Gov't |
7 |
43 |
4
|
Predicting Critical Power in Elite Cyclists: Questioning the Validity of the 3-Minute All-Out Test. Int J Sports Physiol Perform 2016; 12:783-787. [PMID: 27834562 DOI: 10.1123/ijspp.2016-0376] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
PURPOSE New applications of the critical-power concept, such as the modeling of intermittent-work capabilities, are exciting prospects for elite cycling. However, accurate calculation of the required parameters is traditionally time invasive and somewhat impractical. An alternative single-test protocol (3-min all-out) has recently been proposed, but validation in an elite population is lacking. The traditional approach for parameter establishment, but with fewer tests, could also prove an acceptable compromise. METHODS Six senior Australian endurance track-cycling representatives completed 6 efforts to exhaustion on 2 separate days over a 3-wk period. These included 1-, 4-, 6-, 8-, and 10-min self-paced efforts, plus the 3-min all-out protocol. Traditional work-vs-time calculations of CP and anaerobic energy contribution (W') using the 5 self-paced efforts were compared with calculations from the 3-min all-out protocol. The impact of using just 2 or 3 self-paced efforts for traditional CP and W' estimation was also explored using thresholds of agreement (8 W, 2.0 kJ, respectively). RESULTS CP estimated from the 3-min all-out approach was significantly higher than from the traditional approach (402 ± 33, 351 ± 27 W, P < .001), while W' was lower (15.5 ± 3.0, 24.3 ± 4.0 kJ, P = .02). Five different combinations of 2 or 3 self-paced efforts led to CP estimates within the threshold of agreement, with only 1 combination deemed accurate for W'. CONCLUSIONS In elite cyclists the 3-min all-out approach is not suitable to estimate CP when compared with the traditional method. However, reducing the number of tests used in the traditional method lessens testing burden while maintaining appropriate parameter accuracy.
Collapse
|
|
9 |
24 |
5
|
Broxterman RM, Skiba PF, Craig JC, Wilcox SL, Ade CJ, Barstow TJ. W' expenditure and reconstitution during severe intensity constant power exercise: mechanistic insight into the determinants of W'. Physiol Rep 2017; 4:4/19/e12856. [PMID: 27688431 PMCID: PMC5064128 DOI: 10.14814/phy2.12856] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Accepted: 06/16/2016] [Indexed: 11/24/2022] Open
Abstract
The sustainable duration of severe intensity exercise is well-predicted by critical power (CP) and the curvature constant (W'). The development of the W'BAL model allows for the pattern of W' expenditure and reconstitution to be characterized and this model has been applied to intermittent exercise protocols. The purpose of this investigation was to assess the influence of relaxation phase duration and exercise intensity on W' reconstitution during dynamic constant power severe intensity exercise. Six men (24.6 ± 0.9 years, height: 173.5 ± 1.9 cm, body mass: 78.9 ± 5.6 kg) performed severe intensity dynamic handgrip exercise to task failure using 50% and 20% duty cycles. The W'BAL model was fit to each exercise test and the time constant for W' reconstitution (τW') was determined. The τW' was significantly longer for the 50% duty cycle (1640 ± 262 sec) than the 20% duty cycle (863 ± 84 sec, P = 0.02). Additionally, the relationship between τW' and CP was well described as an exponential decay (r(2) = 0.90, P < 0.0001). In conclusion, the W'BAL model is able to characterize the expenditure and reconstitution of W' across the contraction-relaxation cycles comprising severe intensity constant power handgrip exercise. Moreover, the reconstitution of W' during constant power severe intensity exercise is influenced by the relative exercise intensity, the duration of relaxation between contractions, and CP.
Collapse
|
Research Support, U.S. Gov't, Non-P.H.S. |
8 |
14 |
6
|
The Application of Critical Power, the Work Capacity above Critical Power (W'), and its Reconstitution: A Narrative Review of Current Evidence and Implications for Cycling Training Prescription. Sports (Basel) 2020; 8:sports8090123. [PMID: 32899777 PMCID: PMC7552657 DOI: 10.3390/sports8090123] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/28/2020] [Accepted: 09/02/2020] [Indexed: 12/17/2022] Open
Abstract
The two-parameter critical power (CP) model is a robust mathematical interpretation of the power–duration relationship, with CP being the rate associated with the maximal aerobic steady state, and W′ the fixed amount of tolerable work above CP available without any recovery. The aim of this narrative review is to describe the CP concept and the methodologies used to assess it, and to summarize the research applying it to intermittent cycle training techniques. CP and W′ are traditionally assessed using a number of constant work rate cycling tests spread over several days. Alternatively, both the 3-min all-out and ramp all-out protocols provide valid measurements of CP and W′ from a single test, thereby enhancing their suitability to athletes and likely reducing errors associated with the assumptions of the CP model. As CP represents the physiological landmark that is the boundary between heavy and severe intensity domains, it presents several advantages over the de facto arbitrarily defined functional threshold power as the basis for cycle training prescription at intensities up to CP. For intensities above CP, precise prescription is not possible based solely on aerobic measures; however, the addition of the W′ parameter does facilitate the prescription of individualized training intensities and durations within the severe intensity domain. Modelling of W′ reconstitution extends this application, although more research is needed to identify the individual parameters that govern W′ reconstitution rates and their kinetics.
Collapse
|
Review |
5 |
13 |
7
|
Black MI, Jones AM, Kelly JA, Bailey SJ, Vanhatalo A. The constant work rate critical power protocol overestimates ramp incremental exercise performance. Eur J Appl Physiol 2016; 116:2415-2422. [PMID: 27787608 PMCID: PMC5118414 DOI: 10.1007/s00421-016-3491-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Accepted: 10/13/2016] [Indexed: 12/02/2022]
Abstract
Purpose The parameters of the power-duration relationship (i.e., the critical power, CP, and the curvature constant, W′) may theoretically predict maximal performance capability for exercise above the CP. The CP and Wʹ are associated with the parameters of oxygen uptake (\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$${\dot{\text{V}}}$$\end{document}V˙O2) kinetics, which can be altered by manipulation of the work-rate forcing function. We tested the hypothesis that the CP and Wʹ derived from constant work-rate (CWR) prediction trials would overestimate ramp incremental exercise performance. Methods Thirty subjects (males, n = 28; females, n = 2) performed a ramp incremental test, and 3–5 CWR prediction trials for the determination of the CP and Wʹ. Multiple ramp incremental tests and corresponding CP and Wʹ estimates were available for some subjects such that in total 51 ramp test performances were predicted. Results The ramp incremental test performance (729 ± 113 s) was overestimated by the CP and Wʹ estimates derived from the best (751 ± 114 s, P < 0.05) and worst (749 ± 111 s, P < 0.05) individual fits of CWR prediction trial data. The error in the prediction was inversely correlated with the magnitude of the Wʹ for the best (r = −0.56, P < 0.05) and worst individual fits (r = −0.36, P < 0.05). Conclusions The overestimation of ramp incremental performance suggests that the CP and Wʹ derived from different work-rate forcing functions, thus resulting in different \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$${\dot{\text{V}}}$$\end{document}V˙O2 kinetics, cannot be used interchangeably. The present findings highlight a potential source of error in performance prediction that is of importance to both researchers and applied practitioners.
Collapse
|
Journal Article |
9 |
9 |
8
|
Broxterman RM, Craig JC, Ade CJ, Wilcox SL, Barstow TJ. The effect of resting blood flow occlusion on exercise tolerance and W'. Am J Physiol Regul Integr Comp Physiol 2015. [PMID: 26224689 DOI: 10.1152/ajpregu.00283.2015] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
It has previously been postulated that the anaerobic work capacity (W') may be utilized during resting blood flow occlusion in the absence of mechanical work. We tested the hypothesis that W' would not be utilized during an initial range of time following the onset of resting blood flow occlusion, after which W' would be utilized progressively more. Seven men completed blood flow occlusion constant power severe intensity handgrip exercise to task failure following 0, 300, 600, 900, and 1,200 s of resting blood flow occlusion. The work performed above critical power (CP) was not significantly different between the 0-, 300-, and 600-s conditions and was not significantly different from the total W' available. Significantly less work was performed above CP during the 1,200-s condition than the 900-s condition (P < 0.05), while both conditions were significantly less than the 0-, 300-, and 600-s conditions (P < 0.05). The work performed above CP during these conditions was significantly less than the total W' available (P < 0.05). The utilization of W' during resting blood flow occlusion did not begin until 751 ± 118 s, after which time W' was progressively utilized. The current findings demonstrate that W' is not utilized during the initial ∼751 s of resting blood flow occlusion, but is progressively utilized thereafter, despite no mechanical work being performed. Thus, the utilization of W' is not exclusive to exercise, and a constant amount of work that can be performed above CP is not the determining mechanism of W'.
Collapse
|
|
10 |
6 |
9
|
Chorley A, Marwood S, Lamb KL. A dynamic model of the bi-exponential reconstitution and expenditure of W' in trained cyclists. Eur J Sport Sci 2023; 23:2368-2378. [PMID: 37470470 DOI: 10.1080/17461391.2023.2238679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
ABSTRACTThe aim of this study was to investigate the effects of different recovery power outputs on the reconstitution of W' and to develop a dynamic bi-exponential model of W' during depletion and reconstitution. Ten trained cyclists (mass 71.7 ± 8.4 kg; V̇O2max 60.0 ± 6.3 ml·kg-1·min-1) completed three incremental ramps (20 W·min-1) to the limit of tolerance on each of six occasions with recovery durations of 30 and 240 s. Recovery power outputs varied between 50 W (LOW); 60% of critical power (CP) (MOD) and 85% of CP (HVY). W' reconstitution was measured following each recovery and fitted to a bi-exponential model. Amplitude and time constant (τ) parameters were then determined via regression analysis accounting for relative intensity and duration to produce a dynamic model of W'. W' reconstitution slowed disproportionately as recovery power output increased (p < 0.001) and increased with recovery duration (p < 0.001). The amplitudes of each recovery component were strongly correlated to W' reconstitution after 240 s at HVY (r = 0.95), whilst τ parameters were found to be related to the fractional difference between recovery power and CP. The predictive capacity of the resultant model was assessed against experimental data with no differences found between predicted and experimental values of W' reconstitution (p > 0.05). The dynamic bi-exponential model of W' accounting for varying recovery intensities closely described W' kinetics in trained cyclists facilitating real-time decisions about pacing and tactics during competition. The model can be customised for individuals from known CP and W' and a single additional test session.HighlightsA dynamic bi-exponential model of W' accounting for both varying power output and duration.Individual customisation of the model can be achieved with a single specific test session.W' reconstitution slows disproportionally with increasing intensity after repeated bouts.
Collapse
|
|
2 |
|
10
|
Janzen NR, Hight RE, Patel DS, Campbell JA, Larson RD, Black CD. Estimation of critical end-test torque using neuromuscular electrical stimulation of the quadriceps in humans. Eur J Appl Physiol 2018; 118:1407-1414. [PMID: 29721605 DOI: 10.1007/s00421-018-3872-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Accepted: 04/20/2018] [Indexed: 11/24/2022]
Abstract
Characterization of critical power/torque (CP/CT) during voluntary exercise requires maximal effort, making difficult for those with neuromuscular impairments. To address this issue we sought to determine if electrically stimulated intermittent isometric exercise resulted in a critical end-test torque (ETT) that behaved similar to voluntary CT. In the first experiment participants (n = 9) completed four bouts of stimulated exercise at a 3:2 duty cycle, at frequencies of 100, 50, 25 Hz, and a low frequency below ETT (Sub-ETT; ≤ 15 Hz). The second experiment (n = 20) consisted of four bouts at a 2:2 duty cycle-two bouts at 100 Hz, one at an intermediate frequency (15-30 Hz), and one at Sub-ETT. The third experiment (n = 12) consisted of two bouts at 50 Hz at a 3:2 duty* cycle with proximal blood flow occlusion during one of the bouts. ETT torque was similar (p ≥ 0.43) within and among stimulation frequencies in experiment 1. No fatigue was observed during the Sub-ETT bouts (p > 0.05). For experiment 2, ETT was similar at 100 Hz and at the intermediate frequency (p ≥ 0.29). Again, Sub-ETT stimulation did not result in fatigue (p > 0.05). Altering oxygen delivery by altering the duty cycle (3:2 vs. 2:2; p = 0.02) and by occlusion (p < 0.001) resulted in lower ETT values. Stimulated exercise resulted in an ETT that was consistent from day-to-day and similar regardless of initial torque, as long as that torque exceeded ETT, and was sensitive to oxygen delivery. As such we propose it represents a parameter similar to voluntary CT.
Collapse
|
Journal Article |
7 |
|