1
|
Cipriani F, Ariño Palao B, Gonzalez de Torre I, Vega Castrillo A, Aguado Hernández HJ, Alonso Rodrigo M, Àlvarez Barcia AJ, Sanchez A, García Diaz V, Lopez Peña M, Rodriguez-Cabello JC. An elastin-like recombinamer-based bioactive hydrogel embedded with mesenchymal stromal cells as an injectable scaffold for osteochondral repair. Regen Biomater 2019; 6:335-347. [PMID: 31827887 PMCID: PMC6897338 DOI: 10.1093/rb/rbz023] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Revised: 04/17/2019] [Accepted: 04/19/2019] [Indexed: 01/21/2023] Open
Abstract
The aim of this study was to evaluate injectable, in situ cross-linkable elastin-like recombinamers (ELRs) for osteochondral repair. Both the ELR-based hydrogel alone and the ELR-based hydrogel embedded with rabbit mesenchymal stromal cells (rMSCs) were tested for the regeneration of critical subchondral defects in 10 New Zealand rabbits. Thus, cylindrical osteochondral defects were filled with an aqueous solution of ELRs and the animals sacrificed at 4 months for histological and gross evaluation of features of biomaterial performance, including integration, cellular infiltration, surrounding matrix quality and the new matrix in the defects. Although both approaches helped cartilage regeneration, the results suggest that the specific composition of the rMSC-containing hydrogel permitted adequate bone regeneration, whereas the ELR-based hydrogel alone led to an excellent regeneration of hyaline cartilage. In conclusion, the ELR cross-linker solution can be easily delivered and forms a stable well-integrated hydrogel that supports infiltration and de novo matrix synthesis.
Collapse
|
Journal Article |
6 |
18 |
2
|
Liu F, Chen K, Hou L, Li K, Wang D, Zhang B, Wang X. Determining the critical size of a rabbit rib segmental bone defect model. Regen Biomater 2016; 3:323-328. [PMID: 27699063 PMCID: PMC5043152 DOI: 10.1093/rb/rbw028] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Revised: 07/20/2016] [Accepted: 07/26/2016] [Indexed: 12/22/2022] Open
Abstract
In order to establish and standardize the rabbit rib segmental bone defect model, it is of vital importance to determine rabbit rib critical size defect (CSD). According to the general time needed for spontaneous long-bone regeneration, three-month observation period was set to determine the CSD. The rabbit rib segmental bone defects with different sizes from 1 to 5 cm with or without periosteum were performed in the eighth rib of 4-month-old male New Zealand rabbits and underwent X-ray examinations at the 4th, 8th and 12th weeks postoperatively. The gross and histological examinations at postoperative week 12 were evaluated, which showed that the critical sizes in the rabbit rib models with and without periosteum were 5 and 2 cm, respectively. This study provides prerequisite data for establishing rabbit rib CSD model and evaluating bone materials using this model.
Collapse
|
Journal Article |
9 |
10 |
3
|
Abstract
A novel device for distal fixation of a guidewire was tested in regards to deployment and retrieval, deposition in the blood stream and force of fixation in a pig model. Eleven pigs were subjected to full anaesthesia and heparinized to active clotting time 250-350 s. Uninterrupted blood flow during 4 h deposition was assessed by angiography and inspected for thrombus deposition upon retrieval. The force of fixation was investigated up to the level of loss of fixation (displacement force). The device was successfully deployed and retrieved in over 40 cases. In one case, an alternative method for bailout retrieval was used. Deposition for 4 h was performed, and uninterrupted blood flow was verified by angiography. No instances of arterial occlusion or thrombosis were detected. The median dislocation force was 7.6 N. No arterial rupture or dissection was detected following the loss of fixation. As a conclusion, the device was considered safe and functional in this animal test model.
Collapse
|
|
9 |
6 |
4
|
Paparella M, Scholz S, Belanger S, Braunbeck T, Bicherel P, Connors K, Faßbender C, Halder M, Lillicrap A, Liska R, Schirmer K, Stoddart G, Thomas P, Walter-Rohde S. Limitations and uncertainties of acute fish toxicity assessments can be reduced using alternative methods. ALTEX-ALTERNATIVES TO ANIMAL EXPERIMENTATION 2020; 38:20-32. [PMID: 32970822 DOI: 10.14573/altex.2006051] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Accepted: 09/16/2020] [Indexed: 11/23/2022]
Abstract
Information about acute fish toxicity is routinely required in many jurisdictions for environmental risk assessment of chemicals. This information is typically obtained using a 96-hour juvenile fish test for lethality according to OECD test guideline (TG) 203 or equivalent regional guidelines. However, TG 203 has never been validated using the criteria currently required for new test methods including alternative methods. Characterization of the practicality and validity of TG 203 is important to provide a benchmark for alternative methods. This contribution systematically summarizes the available knowledge on limitations and uncertainties of TG 203, based on methodological, statistical, and biological considerations. Uncertainties stem from the historic flexibility (e.g., use of a broad range of species) and constraints of the basic test design (e.g., no replication). Other sources of uncertainty arise from environmental safety extrapolation based on TG 203 data. Environmental extrapolation models, combined with data from alternative methods, including mechanistic indicators of toxicity, may provide at least the same level of environmental protection. Yet, most importantly, the 3R advantages of alternative methods allow a better standardization, characterization, and an improved basic study design. This can enhance data reliability and thus facilitate the comparison of chemical toxicity, as well as the environmental classifications and prediction of no-effect concentrations of chemicals. Combined with the 3R gains and the potential for higher throughput, a reliable assessment of more chemicals can be achieved, leading to improved environmental protection.
Collapse
|
Journal Article |
5 |
5 |
5
|
Yue W, Chen X, He S, Li N, Zhang L, Chen J. Exposure interval to ambient fine particulate matter (PM2.5) collected in Southwest China induced pulmonary damage through the Janus tyrosine protein kinase-2/signal transducer and activator of transcription-3 signaling pathway both in vivo and in vitro. J Appl Toxicol 2021; 41:2042-2054. [PMID: 34081793 DOI: 10.1002/jat.4196] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 04/29/2021] [Accepted: 05/01/2021] [Indexed: 12/20/2022]
Abstract
PM2.5 is a well-known air pollutant threatening public health. Studies confirmed that exposure to the particles could impair pulmonary function, cause chronic obstructive pulmonary disease, and increase the incidence of lung cancer. The characteristic of PM2.5 varies across regions. The toxic function of PM2.5 in southwest China remains to be elucidated. This study aimed to investigate lung injury and its mechanisms induced by PM2.5 collected in Chengdu. Rats were administered with PM2.5 by intratracheal instillation for 4 weeks. Biochemical, cell count, and inflammation-related parameters were measured. Lung tissues were obtained for hematoxylin and eosin and Masson's trichrome staining. The expression levels of vascular endothelial growth factor (VEGF), Janus tyrosine protein kinase-2 (JAK-2), and signal transducer and activator of transcription-3 (STAT-3) were detected by immunohistochemistry assays. Meanwhile, A549 cells were treated with the PM2.5. The cell cycle, and apoptosis were measured by flow cytometry. mRNA and protein expressions of JAK-2, STAT-3, p-STAT-3, and VEGFA were detected using qPCR and Western blot analysis respectively. Results of in vivo study showed that PM2.5 induced lung pathological injury, aggravated the accumulation of inflammatory cells, and increased the serum levels of inflammatory factors. In vitro experiments showed that PM2.5 disrupted the cell growth cycle and increased cell apoptosis through the activation of the JAK-2/STAT-3 signaling pathway. Taken together, this study provided convincing experimental evidence that PM2.5 collected in southwest China could induce pulmonary injury as manifested by inflammatory response and lung fibrosis, possibly through the modulation of the JAK-2/STAT-3 signaling pathway.
Collapse
|
Journal Article |
4 |
2 |
6
|
Seo JW, Park H, Kim D, Lee S, Koh YG, Kim JY, Park I, Lee W. In Vivo Animal Study of a Highly Viscous N-butyl Cyanoacrylate Medical Adhesive for Intravenous Embolization. MATERIALS 2021; 14:ma14133527. [PMID: 34202769 PMCID: PMC8269526 DOI: 10.3390/ma14133527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 06/10/2021] [Accepted: 06/17/2021] [Indexed: 11/16/2022]
Abstract
N-butyl cyanoacrylate (NBCA) is a liquid monomer that undergoes an exothermic polymerization reaction to form a solid upon initiation with hydroxyl anions. Recently, EGpresto, a highly viscous NBCA-based adhesive, has been developed for vascular-occlusion purposes. In this study, we investigated the heat of polymerization of EGpresto and compared the results with those of a low-viscosity NBCA glue. Results show that EGpresto exhibited a lower heat of polymerization (64 ± 7 °C vs. 34 ± 1 °C). This was due to its high viscosity, which resulted in a delayed polymerization time. To investigate the efficacy and safety of EGpresto for intravenous embolization, a 14 d in vivo animal test was conducted using three pigs. Five cc of EGpresto was injected into the epigastric vein of each animal. Complete postoperative vein occlusion was confirmed at 7 and 14 d by ultrasonographic visualization. After the animals were sacrificed, the operated and unoperated veins were exposed, and the injected adhesive was found without migration. During the histology, the injected adhesive was not found in the inner or outer vein walls, and the immune reactions seemed to be the only foreign-body reaction, showing that EGpresto is a non-toxic and safe intravascular embolic agent.
Collapse
|
Journal Article |
4 |
|
7
|
Ito T, Ota T, Kono R, Miyaoka Y, Ishibashi H, Komori M, Yasukawa A, Kanno Y, Miki N. Pump-Free Microfluidic Hemofiltration Device. MICROMACHINES 2021; 12:mi12080992. [PMID: 34442614 PMCID: PMC8401791 DOI: 10.3390/mi12080992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 08/16/2021] [Accepted: 08/18/2021] [Indexed: 11/16/2022]
Abstract
Hemofiltration removes water and small molecules from the blood via nanoporous filtering membranes. This paper discusses a pump-free hemofiltration device driven by the pressure difference between the artery and the vein. In the design of the filtering device, oncotic pressure needs to be taken into consideration. Transmembrane pressure (TMP) determines the amount and direction of hemofiltration, which is calculated by subtracting the oncotic pressure from the blood pressure. Blood pressure decreases as the channels progress from the inlet to the outlet, while oncotic pressure increases slightly since no protein is removed from the blood to the filtrate in hemofiltration. When TMP is negative, the filtrate returns to the blood, i.e., backfiltration takes place. A small region of the device with negative TMP would thus result in a small amount of or even zero filtrates. First, we investigated this phenomenon using in vitro experiments. We then designed a hemofiltration system taking backfiltration into consideration. We divided the device into two parts. In the first part, the device has channels for the blood and filtrate with a nanoporous membrane. In the second part, the device does not have channels for filtration. This design ensures TMP is always positive in the first part and prevents backfiltration. The concept was verified using in vitro experiments and ex vivo experiments in beagle dogs. Given the simplicity of the device without pumps or electrical components, the proposed pump-free hemofiltration device may prove useful for either implantable or wearable hemofiltration.
Collapse
|
|
4 |
|
8
|
Doi K, Takeuchi S, Yamazaki H, Tsuji T, Kawano S. Fluid-Structure Interaction Analysis of Trapezoidal and Arc-Shaped Membranes Mimicking the Organ of Corti. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2025; 41:e3896. [PMID: 39721994 DOI: 10.1002/cnm.3896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 04/25/2024] [Accepted: 11/29/2024] [Indexed: 12/28/2024]
Abstract
In a previous study [H. Shintaku et al., Sensors and Actuators A: Physical 158 (2010): 183-192], an artificially developed auditory sensor device showed a frequency selectivity in the range from 6.6 to 19.8 kHz in air and from 1.4 to 4.9 kHz in liquid. Furthermore, the sensor succeeded in obtaining auditory brain-stem responses in deafened guinea pigs [T. Inaoka et al., Proceedings of the National Academy of Sciences of the United States of America 108 (2011): 18390-18395]. Since then, several research groups have developed piezoelectric auditory devices that have the capability of acoustic/electric conversion. However, the piezoelectric devices are required to be optimally designed with respect to the frequency range in liquids. In the present study, focusing on the trapezoidal shape of the piezoelectric membrane, the vibration characteristics are numerically and experimentally investigated. In the numerical analysis, solving a three-dimensional fluid-structure interaction problem, resonant frequencies of the trapezoidal membrane are evaluated. Herein, Young's modulus of the membrane, which is made of polyvinylidene difluoride and is different from that of bulk, is properly determined to reproduce the experimental results measured in air. Using the modified elastic modulus for the membrane, the vibration modes and resonant frequencies in liquid are in good agreement with experimental results. It is also found that the resonant characteristics of the artificial basilar membrane for guinea pigs are quantitatively reproduced, considering the fluid-structure interaction. The present numerical method predicts experimental results and is available to improve the frequency selectivity of the piezoelectric membranes for artificial cochlear devices.
Collapse
|
|
1 |
|
9
|
Billström GH, Lopes VR, Illies C, Gallinetti S, Åberg J, Engqvist H, Aparicio C, Larsson S, Linder LKB, Birgersson U. Guiding bone formation using semi-onlay calcium phosphate implants in an ovine calvarial model. J Tissue Eng Regen Med 2022; 16:435-447. [PMID: 35195935 PMCID: PMC9303616 DOI: 10.1002/term.3288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 01/02/2022] [Accepted: 01/29/2022] [Indexed: 11/14/2022]
Abstract
The restoration of cranio‐maxillofacial deformities often requires complex reconstructive surgery in a challenging anatomical region, with abnormal soft tissue structures and bony deficits. In this proof‐of‐concept, the possibility of vertical bone augmentation was explored by suspending hemispherically shaped titanium‐reinforced porous calcium phosphate (CaP) implants (n = 12) over the frontal bone in a sheep model (n = 6). The animals were euthanized after week 13 and the specimens were subject to micro‐computed tomography (μCT) and comprehensive histological analysis. Histology showed that the space between implant and the recipient bone was filled with a higher percentage of newly formed bone (NFB) versus soft tissue with a median of 53% and 47%, respectively. Similar results were obtained from the μ‐CT analysis, with a median of 56% NFB and 44% soft tissue filling the void. Noteworthy, significantly higher bone‐implant contact was found for the CaP (78%, range 14%–94%) versus the Titanium (29%, range 0%–75%) portion of the implant exposed to the surrounding bone. The histological analysis indicates that the CaP replacement by bone is driven by macrophages over time, emphasized by material‐filled macrophages found in close vicinity to the CaP with only a small number of single osteoclasts found actively remodeling the NFB. This study shows that CaP based implants can be assembled with the help of additive manufacturing to guide vertical bone formation without decortification or administration of growth factors. Furthermore, it highlights the potential disadvantage of a seamless fit between the implant and the recipient's bone.
Collapse
|
|
3 |
|
10
|
Feng H, Wang S, Wang Y, Li X, Wang X. [Study on mechanical properties of nitinol iliac vein stent and animal test under different release scales]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2019; 36:1024-1031. [PMID: 31875378 DOI: 10.7507/1001-5515.201807006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The mechanical properties of nitinol iliac vein stent (NIVS) have been studied by many scholars at home and abroad, but the study on the mechanical properties of iliac vein stent under different release scales has not been reported yet. Based on the finite element analysis method, the mechanical properties of three self-developed NIVS were studied to reveal the influence of stent diameters (12, 14, 16 mm) and different release scales (80%, 90%) on its strength, fatigue life and vein wall biomechanical properties. With an increases in the release scales, the equivalent elastic strain, fatigue strength safety factors, and vessel wall equivalent stress exhibited a downward trend, while the most stressed cross-section coincided with the arc of stent-connecting rods. Through 30, 60 and 90 days' animal test, a narrowed vascular model was established in the iliac veins of 12 pigs, and the developed iliac vein stents were implanted to comprehensively evaluate the safety and effectiveness of the stent, and at the same time the mechanical properties of stents were verified to provide important reference for the type inspection and clinical trials of follow-up products.
Collapse
|
|
6 |
|