1
|
Jose J, Sulimov DS, El-Mawardy M, Sato T, Allali A, Holy EW, Becker B, Landt M, Kebernik J, Schwarz B, Richardt G, Abdel-Wahab M. Clinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement: Incidence, Characteristics, and Treatment Outcomes. JACC Cardiovasc Interv 2017; 10:686-697. [PMID: 28385406 DOI: 10.1016/j.jcin.2017.01.045] [Citation(s) in RCA: 184] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Revised: 01/23/2017] [Accepted: 01/27/2017] [Indexed: 10/19/2022]
Abstract
OBJECTIVES The aim of this study was to determine the incidence, characteristics, and treatment outcomes of patients diagnosed with clinical transcatheter heart valve thrombosis. BACKGROUND Limited data exists on clinical or manifest transcatheter heart valve thrombosis. Prior studies have focused on subclinical thrombosis. METHODS A retrospective analysis was conducted of prospectively collected data from a single-center registry that included 642 consecutive patients who underwent transcatheter aortic valve replacement between 2007 and 2015 (305 patients had self-expanding valves; balloon-expandable, n = 281; mechanically expanding, n = 56). Long-term oral anticoagulation (OAC) was indicated in 261 patients, while 377 patients received dual-antiplatelet therapy post-procedure. All patients underwent scheduled clinical and echocardiographic follow-up. RESULTS The overall incidence of clinical valve thrombosis was 2.8% (n = 18). No patient on OAC developed thrombosis. Of the detected thrombosis cases, 13 patients had balloon-expandable, 3 had self-expanding, and 2 had mechanically expanding valves. Thrombosis occurred significantly more often with balloon-expandable valves (odds ratio: 3.45; 95% confidence interval: 1.22 to 9.81; p = 0.01) and following valve-in-valve procedures (odds ratio: 5.93; 95% confidence interval: 2.01 to 17.51; p = 0.005). Median time to diagnosis of valve thrombosis was 181 days. The median N-terminal pro-brain natriuretic peptide level was 1,318 pg/ml (interquartile range: 606 to 1,676 pg/ml). The mean transvalvular gradient and valve area were 34 ± 14 mm Hg and 1.0 ± 0.46 cm2, respectively. Computed tomography showed hypoattenuating areas with reduced leaflet motion. Initiation of OAC resulted in significant reduction of transvalvular gradient and clinical improvement. No deaths were related to valve thrombosis. CONCLUSIONS Clinical transcatheter heart valve thrombosis is more common than previously considered, characterized by imaging abnormalities and increased gradients and N-terminal pro-brain natriuretic peptide levels. It occurred more commonly after balloon-expandable transcatheter aortic valve replacement and valve-in-valve procedures. OAC appeared to be effective in the prevention and treatment of valve thrombosis. Randomized control trials are needed to define optimal antithrombotic therapy after transcatheter aortic valve replacement.
Collapse
|
Journal Article |
8 |
184 |
2
|
Abdel-Wahab M, Landt M, Neumann FJ, Massberg S, Frerker C, Kurz T, Kaur J, Toelg R, Sachse S, Jochheim D, Schäfer U, El-Mawardy M, Robinson DR, Richardt G. 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial. JACC Cardiovasc Interv 2020; 13:1071-1082. [PMID: 32305398 DOI: 10.1016/j.jcin.2019.12.026] [Citation(s) in RCA: 150] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 12/02/2019] [Accepted: 12/17/2019] [Indexed: 12/13/2022]
Abstract
OBJECTIVES The purpose of this study was to evaluate clinical and echocardiographic outcome data of the CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients with Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT) trial at 5 years. BACKGROUND The CHOICE trial was designed to compare device performance of a balloon-expandable (BE) transcatheter heart valve (THV) versus a self-expanding (SE) THV. METHODS The CHOICE trial is an investigator-initiated trial that randomized 241 high-risk patients with severe symptomatic aortic stenosis and an anatomy suitable for treatment with both BE and SE THVs to transfemoral transcatheter aortic valve replacement with either device. The primary endpoint was device success. Patients were followed up to 5 years, with assessment of clinical outcomes, and echocardiographic evaluation of valve function and THV durability. RESULTS After 5 years, there were no statistically significant differences between BE and SE valves in the cumulative incidence of death from any cause (53.4% vs. 47.6%; p = 0.38), death from cardiovascular causes (31.6% vs. 21.5%; p = 0.12), all strokes (17.5% vs. 16.5%; p = 0.73), and repeat hospitalization for heart failure (28.9% vs. 22.5%; p = 0.75). SE patients had larger prosthetic valve area (1.6 ± 0.5 cm2 vs. 1.9 ± 0.5 cm2; p = 0.02) with a lower mean transprosthetic gradient (12.2 ± 8.7 mm Hg vs. 6.9 ± 2.7 mm Hg; p = 0.001) at 5 years. No differences were observed in the rates of paravalvular regurgitation. Clinical valve thrombosis occurred in 7 BE patients (7.3%) and 1 SE patient (0.8%; p = 0.06), and moderate or severe structural valve deterioration in 6 BE patients (6.6%) and no SE patient (0%; p = 0.018). The rate of bioprosthetic valve failure was low and not significantly different between both groups (4.1% vs. 3.4%; p = 0.63). CONCLUSIONS Five-year follow-up of patients in the CHOICE trial revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with early-generation BE and SE valves that were not statistically significantly different, with limited statistical power. Forward flow hemodynamics were significantly better with the SE valve. Moderate or severe structural valve deterioration was uncommon but occurred more frequently with the BE valve. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial [CHOICE]; NCT01645202).
Collapse
|
Research Support, Non-U.S. Gov't |
5 |
150 |
3
|
Sá MPBO, Simonato M, Van den Eynde J, Cavalcanti LRP, Alsagheir A, Tzani A, Fovino LN, Kampaktsis PN, Gallo M, Laforgia PL, Ruhparwar A, Weymann A, Hirji SA, Kaneko T, H L Tang G. Balloon versus self-expandable transcatheter aortic valve implantation for bicuspid aortic valve stenosis: A meta-analysis of observational studies. Catheter Cardiovasc Interv 2021; 98:E746-E757. [PMID: 33555107 DOI: 10.1002/ccd.29538] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 12/15/2020] [Accepted: 01/17/2021] [Indexed: 12/21/2022]
Abstract
BACKGROUND There is a rising trend for transcatheter aortic valve implantation (TAVI) in bicuspid aortic stenosis patients. Data on the use of self-expandable (SEV) vs. balloon-expandable (BEV) valves in these patients are scarce. Therefore, we systematically compared clinical outcomes in bicuspid aortic stenosis patients treated with SEV and BEV. METHODS Data were extracted from PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, Google Scholar and reference lists of relevant articles. Eight studies published from 2013 to 2020 including a total of 1,080 patients (BEV: n = 620; SEV: n = 460) were selected. Primary endpoints were procedural, 30-day and 1-year mortality. Secondary endpoints were new pacemaker implantation, annular rupture, coronary obstruction, moderate-to-severe paravalvular leak, need of second valve, stroke and acute kidney injury. RESULTS We found no statistically significant difference in mortality between patients treated with BEV vs. SEV during index procedure, at 30 days and at 1 year. BEVs showed a statistically significant higher risk of annulus rupture (2.5%) in comparison with SEV (0%) (OR 5.81 [95% CI, 3.78-8.92], p < .001). New generation BEVs were also associated with significantly less paravalvular leak when compared to new generation SEVs (OR 0.08 [95% CI, 0.02-0.35], p = .001). CONCLUSIONS This meta-analysis of observational studies of TAVI for bicuspid valves, showed no difference in short- and mid-term TAVI mortality with BEVs and SEVs. BEVs presented a higher risk of annular rupture in comparison with SEV.
Collapse
|
Journal Article |
4 |
18 |
4
|
Appa H, Park K, Bezuidenhout D, van Breda B, de Jongh B, de Villiers J, Chacko R, Scherman J, Ofoegbu C, Swanevelder J, Cousins M, Human P, Smith R, Vogt F, Podesser BK, Schmitz C, Conradi L, Treede H, Schröfel H, Fischlein T, Grabenwöger M, Luo X, Coombes H, Matskeplishvili S, Williams DF, Zilla P. The Technological Basis of a Balloon-Expandable TAVR System: Non-occlusive Deployment, Anchorage in the Absence of Calcification and Polymer Leaflets. Front Cardiovasc Med 2022; 9:791949. [PMID: 35310972 PMCID: PMC8928444 DOI: 10.3389/fcvm.2022.791949] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2021] [Accepted: 01/18/2022] [Indexed: 12/14/2022] Open
Abstract
Leaflet durability and costs restrict contemporary trans-catheter aortic valve replacement (TAVR) largely to elderly patients in affluent countries. TAVR that are easily deployable, avoid secondary procedures and are also suitable for younger patients and non-calcific aortic regurgitation (AR) would significantly expand their global reach. Recognizing the reduced need for post-implantation pacemakers in balloon-expandable (BE) TAVR and the recent advances with potentially superior leaflet materials, a trans-catheter BE-system was developed that allows tactile, non-occlusive deployment without rapid pacing, direct attachment of both bioprosthetic and polymer leaflets onto a shape-stabilized scallop and anchorage achieved by plastic deformation even in the absence of calcification. Three sizes were developed from nickel-cobalt-chromium MP35N alloy tubes: Small/23 mm, Medium/26 mm and Large/29 mm. Crimp-diameters of valves with both bioprosthetic (sandwich-crosslinked decellularized pericardium) and polymer leaflets (triblock polyurethane combining siloxane and carbonate segments) match those of modern clinically used BE TAVR. Balloon expansion favors the wing-structures of the stent thereby creating supra-annular anchors whose diameter exceeds the outer diameter at the waist level by a quarter. In the pulse duplicator, polymer and bioprosthetic TAVR showed equivalent fluid dynamics with excellent EOA, pressure gradients and regurgitation volumes. Post-deployment fatigue resistance surpassed ISO requirements. The radial force of the helical deployment balloon at different filling pressures resulted in a fully developed anchorage profile of the valves from two thirds of their maximum deployment diameter onwards. By combining a unique balloon-expandable TAVR system that also caters for non-calcific AR with polymer leaflets, a powerful, potentially disruptive technology for heart valve disease has been incorporated into a TAVR that addresses global needs. While fulfilling key prerequisites for expanding the scope of TAVR to the vast number of patients of low- to middle income countries living with rheumatic heart disease the system may eventually also bring hope to patients of high-income countries presently excluded from TAVR for being too young.
Collapse
|
research-article |
3 |
14 |
5
|
García-Gómez M, Delgado-Arana JR, Halim J, De Marco F, Trani C, Martin P, Won-Keun K, Montorfano M, den Heijer P, Bedogni F, Sardella G, IJsselmuiden AJJ, Campante Teles R, Aristizabal-Duque CH, Gordillo X, Santos-Martinez S, Barrero A, Gómez-Salvador I, Ancona M, Redondo A, Román JAS, Amat-Santos IJ. Next-generation balloon-expandable Myval transcatheter heart valve in low-risk aortic stenosis patients. Catheter Cardiovasc Interv 2021; 99:889-895. [PMID: 34390296 DOI: 10.1002/ccd.29923] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 07/26/2021] [Accepted: 08/02/2021] [Indexed: 11/10/2022]
Abstract
OBJECTIVES We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. BACKGROUND The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. METHODS Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. RESULTS Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 ± 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 ± 0.8% and 2.2 ± 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 ± 0.2 vs. 2.1 ± 0.6 cm2 ) and mean aortic valve gradient (43.4 ± 11.1 vs. 9.0 ± 3.7 mmHg) improved significantly (p < 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. CONCLUSIONS Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted.
Collapse
|
Journal Article |
4 |
14 |
6
|
Renker M, Kim WK. Choice of transcatheter heart valve: should we select the device according to each patient's characteristics or should it be "one valve fits all"? ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:961. [PMID: 32953761 PMCID: PMC7475391 DOI: 10.21037/atm.2020.04.13] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Since its introduction at the beginning of the century, transcatheter aortic valve replacement (TAVR) has implicated a paradigm shift in the treatment of patients with symptomatic aortic valve stenosis. The past years have brought about major improvements of procedural outcomes owing to advances in imaging and patient selection, global experience, and device technology. Whereas in the early stages of TAVR, only two different devices with limited sizes and access options were used, currently a variety of different transcatheter heart valves (THVs) are available. This has expanded the spectrum of patients that can be treated with TAVR and has allowed for sophisticated device selection tailored to the patients' individual anatomy and comorbidities. The big question is whether such a customized device selection is really necessary-or is there one valve type that fits all patients? With this question in mind, the authors provide an overview of contemporary THVs, including technical specifications and clinical data, that help us to understand the potential value of a differential use of THVs.
Collapse
|
Review |
5 |
14 |
7
|
Nana P, Spanos K, Brodis A, Panuccio G, Kouvelos G, Behrendt CA, Giannoukas A, Kölbel T. Meta-analysis of Comparative Studies Between Self- and Balloon-Expandable Bridging Stent Grafts in Branched Endovascular Aneurysm Repair. J Endovasc Ther 2022; 30:336-346. [PMID: 35293261 DOI: 10.1177/15266028221083458] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE Currently there is no robust evidence which type of bridging stent graft provides better outcomes after branched endovascular aortic repair (BEVAR). Self-expanding (SESG) and balloon-expandable (BESG) stent grafts are both commonly used to connect branches to their respective target vessels (TV). The aim of the current review was to evaluate the impact of the type of bridging stent grafts on TV outcomes during the mid-term follow-up after BEVAR. MATERIALS AND METHODS The study protocol was registered to the PROSPERO (CRD42021274766). A search of the English literature was conducted, using PubMed and EMBASE databases via Ovid and Cochrane database via CENTRAL, from inception to June 30, 2021, using the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. Only comparative studies on BEVAR reporting TV outcomes related to BESG vs SESG were considered eligible. Individual studies were assessed for risk of bias using the Newcastle Ottawa Scale. The Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach was used to evaluate the quality of evidence. The primary outcomes were primary patency, freedom from endoleak, TV instability, and re-intervention between BESG and SESG, used as bridging stents in branches. The outcomes were summarized as odds ratio along with their 95% confidence intervals (CI), through a paired meta-analysis. RESULTS Five out of 609 articles published from 2016 to 2020 were included in the analysis. In total, 1406 TV were revascularized, 547 (38.9 %) with BESGs and 859 with SESGs. The overall pooled primary patency (odds ratio [OR], 0.40; 95% confidence interval [CI], 0.29-1.09; p=.256, I2=4.24%) and freedom from branch-related endoleak (OR, 0.65; 95% CI, 0.17-1.48; p<.122, I2=0.18%) did not differ between the stent types during the available follow-up (17 months, range = 12-35 months). In 4 studies (619 TV), SESG required fewer secondary interventions (OR, 1.04; 95% CI, 0.23-1.83; p=.009, I2=0%) and TV instability rate was lower (OR, 0.99; 95% CI, 0.33-1.65; p=.003, I2=0%) compared with BESG during the available follow-up. CONCLUSION BESG and SESG seem to perform similarly in terms of primary patency and branch-related endoleak during the mid-term follow-up. Current data from retrospective studies suggest that overall TV instability and re-intervention rates are favorable for SESG as bridging stent grafts in BEVAR.
Collapse
|
|
3 |
9 |
8
|
Jose J, Richardt G, Abdel-Wahab M. Balloon- or Self-Expandable TAVI: Clinical Equipoise? Interv Cardiol 2015; 10:103-108. [PMID: 29588684 DOI: 10.15420/icr.2015.10.2.103] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has become an effective treatment option for patients with severe aortic stenosis and high surgical risk or contraindications for surgical aortic valve replacement. Most of the currently available prostheses employ either balloon-expandable or self-expandable designs. Presently, there is a paucity of data directly comparing these two widely used prosthesis types. Forthcoming trials will reveal whether newer designs of both technologies translate into fewer complications and better outcomes, with expansion of TAVI indications. This manuscript reviews features and clinical outcomes of balloon- and self-expanding prostheses, summarising current data from registries and trials.
Collapse
|
Journal Article |
10 |
7 |
9
|
Kumar GP, Yuan S, Cui F, Branicio PS, Jafary-Zadeh M. Nanoglass-based balloon expandable stents. J Biomed Mater Res B Appl Biomater 2019; 108:73-79. [PMID: 30895727 DOI: 10.1002/jbm.b.34367] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 01/30/2019] [Accepted: 02/27/2019] [Indexed: 12/17/2022]
Abstract
Here, a prototypical metallic nanoglass is proposed as a new alloy for balloon expandable stents. Traditionally, the stainless steel SS 316L alloy has been used as a preferred material for this application due to its proper combination of mechanical properties, corrosion resistance, and biocompatibility. Recently, metallic glasses (MGs) have been considered as promising materials for biodevice applications. MGs often display outstanding mechanical properties superior to those of conventional metallic alloys and overcome some of the weaknesses of SS 316L, such as radiopacity, stainless steel allergy, and thrombosis-induced restenosis. However, commonly used monolithic MGs, which have an amorphous homogeneous microstructure, suffer from lack of ductility that is necessary for deployment of balloon expandable stents. In contrast, nanoglasses, that is, amorphous alloys with heterogeneous microstructure, exhibit enhanced ductility which makes them promising materials for balloon expandable stents. We evaluate the feasibility of a prototypical Zr64 Cu36 nanoglass with a grain size of 5 nm for balloon expandable stents by performing finite element method modeling of the stent deployment process in a coronary artery. We consider the BX-Velocity stent design and the nanoglass mechanical properties calculated from atomistic simulations. The results suggest that nanoglasses are suitable materials for balloon expandable stent applications. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 108B:73-79, 2020.
Collapse
|
|
6 |
6 |
10
|
Balloon-Expandable versus Self-Expandable Valves in Transcatheter Aortic Valve Implantation: Complications and Outcomes from a Large International Patient Cohort. J Clin Med 2021; 10:jcm10174005. [PMID: 34501454 PMCID: PMC8432462 DOI: 10.3390/jcm10174005] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 08/12/2021] [Accepted: 08/31/2021] [Indexed: 12/04/2022] Open
Abstract
Background: Both balloon-expandable (BE) and self-expandable (SE) valves for transcatheter aortic valve implantation (TAVI) are broadly used in clinical practice. However, adequately powered randomized controlled trials comparing these two valve designs are lacking. Methods: The CENTER-study included 12,381 patients undergoing transfemoral TAVI. Patients undergoing TAVI with a BE-valve (n = 4096) were compared to patients undergoing TAVI with an SE-valve (n = 4096) after propensity score matching. Clinical outcomes including one-year mortality and stroke rates were assessed. Results: In the matched population of n = 5410 patients, the mean age was 81 ± 3 years, 60% was female, and the STS-PROM predicted 30-day mortality was 6.2% (IQR 4.0–12.4). One-year mortality was not different between patients treated with BE- or SE-valves (BE: 16.4% vs. SE: 17.0%, Relative Risk 1.04, 95%CI 0.02–1.21, p = 0.57). One-year stroke rates were also comparable (BE: 4.9% vs. SE: 5.3%, RR 1.09, 95%CI 0.86–1.37, p = 0.48). Conclusion: This study suggests that one-year mortality and stroke rates were comparable in patients with severe aortic valve stenosis undergoing TAVI with either BE or SE-valves.
Collapse
|
|
4 |
5 |
11
|
Sengottuvelu G, Kumar V, Seth A. The Myval Transcatheter Heart Valve System for the Treatment of Severe Aortic Stenosis - Current Evidence and Future Directions. Heart Int 2020; 14:86-91. [PMID: 36276512 PMCID: PMC9524723 DOI: 10.17925/hi.2020.14.2.86] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 12/17/2020] [Indexed: 08/29/2023] Open
Abstract
Transcatheter aortic valve replacement has revolutionised the treatment of aortic valve disease. The Myval™ device (Meril Life Sciences Pvt. Ltd., Gujarat, India) is a CE-marked, next-generation balloon-expandable transcatheter heart valve, designed for the treatment of severe aortic valve stenosis. This review illustrates the salient technical features of this transcatheter valve, pre-clinical studies and evidence from the first-in-human trial. We also provide a brief overview of planned clinical trials and registries.
Collapse
|
Review |
5 |
3 |
12
|
Kooistra NH, Intan-Goey VMP, Ziviello F, Leenders GE, Kraaijeveld AO, Doevendans PA, Van Mieghem NM, Voskuil M, Stella PR. Comparison of the Sapien 3 versus the ACURATE neo valve system: A propensity score analysis. Catheter Cardiovasc Interv 2020; 97:E597-E606. [PMID: 32886869 PMCID: PMC7984444 DOI: 10.1002/ccd.29240] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 07/31/2020] [Accepted: 08/17/2020] [Indexed: 11/30/2022]
Abstract
Objectives To compare the outcomes of transfemoral ACURATE neo (NEO) and Sapien 3 (S3) patients in terms of device success and clinical safety outcomes using a propensity score analysis. Background Differences in clinical outcomes between the latest‐generation balloon‐expandable S3 and self‐expanding NEO in a “real‐world transfemoral TAVI population” are still unclear. Methods We compared up to 6 months clinical outcomes using a propensity score analysis (inverse probability of treatment weighting [IPTW]) to account for differences in baseline characteristics. Results A total of 345 patients underwent transfemoral transcatheter aortic valve implantation (TAVI) with either NEO or S3 at two centers in the Netherlands. Composite device success and early safety endpoints were comparable between NEO and S3 (Device success: IPTW‐adjusted OR: 0.35 [95% CI: 0.12–1.18], and early safety: IPTW‐adjusted OR: 0.51 [95% CI: 0.19–1.38]). Six‐months mortality was 5.3 versus 3.6%, stroke was 2.8 versus 3.3%, and pacemaker rate was 6.1 versus 8.6%, respectively with p = NS. Mean aortic gradient was lower in the NEO group (5.72 ± 2.47 vs. 9.05 ± 3.48; p = <.001), with a comparable rate of moderate or severe paravalvular leak (0 versus 2.1%; p = NS). Conclusions Device success and clinical safety outcomes were comparable for both valves. Up to 6‐months follow‐up clinical outcomes and mortality rate remained excellent. Mean aortic gradient was lower after ACURATE neo implantation.
Collapse
|
Journal Article |
5 |
1 |
13
|
Muacevic A, Adler JR, Jilani TN, Levisman J. Annular Rupture Due to Calcified Nodule Located in Left Ventricular Outflow Tract (LVOT) During Transcatheter Aortic Valve Replacement (TAVR) Managed by Protamine Sulfate. Cureus 2023; 15:e33417. [PMID: 36751162 PMCID: PMC9899131 DOI: 10.7759/cureus.33417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/05/2023] [Indexed: 01/06/2023] Open
Abstract
Annular rupture is a rare yet fatal complication of transcatheter aortic valve replacement (TAVR). The likelihood of annular rupture is increased by the presence of extensive subannular calcification, excessive balloon dilatation for valve expansion or aggressive valve oversizing to prevent paravalvular leakage during TAVR. Although extensive annular or aortic root calcification increases the likelihood of annular rupture, rupture due to the presence of a calcified nodule in the left ventricular outflow tract (LVOT) is not commonly reported. We present the case of an 84-year-old man who developed an annular rupture during TAVR, likely due to the presence of a calcified nodule located in LVOT, which was noted on a pre-procedural computed tomography (CT) scan. The rupture was identified early and was successfully reversed with the administration of protamine sulfate during the procedure.
Collapse
|
case-report |
2 |
|
14
|
Matta A, Kanso M, Kibler M, Carmona A, Trimaille A, Levai L, Greciano S, Plastaras P, Rischner J, Depoli F, Ledet P, Kindo M, Hoang M, Morel O, Ohlmann P. Long-Term Survival Outcomes After Transcatheter Aortic Valve Replacement: A Real-World Experience of a Large Tertiary Center. Am J Cardiol 2023; 207:229-236. [PMID: 37769567 DOI: 10.1016/j.amjcard.2023.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 08/30/2023] [Accepted: 09/02/2023] [Indexed: 10/03/2023]
Abstract
Transcatheter aortic valve replacement (TAVR) becomes the leading therapeutic choice for severe aortic stenosis. There is a growing body of knowledge on long-term survival outcomes, but available data from real-world observational studies are scarce. An observational cohort study was conducted on 705 consecutive patients who underwent TAVR at Strasbourg University Hospital between February 2010 and June 2017. We observed the living status (dead or alive) for each study participants by March 2023. The primary end point was to evaluate the all-cause mortality rate beyond 5 years after TAVR, compare the survival outcomes according to valve type, and identify predictors of mortality. Of the 705 study participants, 91.8% of the TAVR procedures were performed through the common femoral artery and 60.6% were treated with a balloon-expandable valve. Over a mean study period of 5.4 ± 3 years, the all-cause mortality rate was 45.8%. No difference in survival outcomes according to valve type was observed (p = 0.449). All-cause mortality rate was associated with age ≥90 years (hazard ratio [HR] 1.625, 1.109 to 2.380, p = 0.013), female gender (HR 0.228, 0.176 to 0.294, p <0.001), diabetes mellitus (HR 1.356, 1.070 to 1.719, p = 0.012), post-TAVR stroke (HR = 2.867, 1.690 to 4.865, p <0.001), and post-TAVR acute kidney injury (HR 1.977, 1.445 to 2.703, p <0.001). In conclusion, the present real-world large tertiary center experience showed that more than half of patients who underwent TAVR are alive beyond 5 years from procedure's date. All-cause mortality is mainly determined by advanced age and co-morbid conditions, and valve type has no advantage on the survival outcomes.
Collapse
|
Observational Study |
2 |
|
15
|
Amat-Santos IJ, García-Gómez M. SAPIEN 3 Ultra Resilia: Critical Reflections on Real-World Performance. JACC Cardiovasc Interv 2024; 17:1045-1046. [PMID: 38658118 DOI: 10.1016/j.jcin.2024.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Accepted: 03/04/2024] [Indexed: 04/26/2024]
|
Editorial |
1 |
|
16
|
Chen S, Dizon JM, Hahn RT, Pibarot P, George I, Zhao Y, Blanke P, Kapadia S, Babaliaros V, Szeto WY, Makkar R, Thourani VH, Webb JG, Mack MJ, Leon MB, Kodali S, Nazif TM. Predictors and 5-Year Clinical Outcomes of Pacemaker After TAVR: Analysis From the PARTNER 2 SAPIEN 3 Registries. JACC Cardiovasc Interv 2024; 17:1325-1336. [PMID: 38866455 DOI: 10.1016/j.jcin.2024.03.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 03/07/2024] [Accepted: 03/10/2024] [Indexed: 06/14/2024]
Abstract
BACKGROUND Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.
Collapse
|
Multicenter Study |
1 |
|
17
|
Kim WK, Pellegrini C, Eckel C, Renker M, Grothusen C, Choi YH, Charitos EI, Duesmann C, Blumenstein J, Rheude T, Sossalla S, Joner M, Möllmann H. 1-Year Outcomes of Transcatheter Aortic Valve Replacement Using a Self-Expanding vs Balloon-Expandable Transcatheter Aortic Valve. JACC Cardiovasc Interv 2025; 18:32-40. [PMID: 39570230 DOI: 10.1016/j.jcin.2024.09.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 08/28/2024] [Accepted: 09/17/2024] [Indexed: 11/22/2024]
Abstract
BACKGROUND Mid-term comparative data for the self-expanding ACURATE neo2 transcatheter heart valve and the balloon-expandable SAPIEN 3 Ultra are lacking. OBJECTIVES The aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement of these 2 valves. METHODS A total of 2,106 patients from 3 centers (neo2, n = 1,166; Ultra, n = 940) undergoing transfemoral transcatheter aortic valve replacement were analyzed retrospectively. The primary endpoint was the composite of all-cause mortality, stroke, and rehospitalization at 1 year. Secondary endpoints were the individual components of the primary endpoint at 1 year. To adjust for baseline differences, nearest neighbor propensity score matching was used. RESULTS After matching (702 pairs), baseline characteristics were similar between groups. Device success was more common in the neo2 group (87.5% vs 82.3%; P = 0.007), irrespective of matching. DP mean after the procedure was higher for Ultra (13 mm Hg [Q1-Q3: 10-15 mm Hg] vs 8 mm Hg [Q1-Q3: 6-11] mm Hg; P < 0.001). Rates of paravalvular leakage, device embolization, and multiple valve implantations were more common in the neo2 arm, whereas major cardiac structural complications and major vascular complications occurred more frequently in the Ultra group. All other in-hospital complication rates were similar between the 2 groups. At 1 year, the cumulative incidence of the primary endpoint (14.1% for neo2 vs 14.5% for Ultra; P = 0.819) was similar between the groups. Likewise, the individual components showed no difference between the groups. CONCLUSIONS Despite differing immediate results, the outcomes at 1 year, including the composite of all-cause mortality, stroke, or hospitalization, were similar for neo2 and Ultra transcatheter heart valves.
Collapse
|
Comparative Study |
1 |
|
18
|
Tchétché D, De Biase C. Implementation of the Cusp-Overlap Technique for TAVR With Balloon-Expandable Devices: Another Step Toward Standardization. JACC Cardiovasc Interv 2022; 15:2396-2397. [PMID: 36402717 DOI: 10.1016/j.jcin.2022.10.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 10/23/2022] [Indexed: 11/18/2022]
|
Editorial |
3 |
|
19
|
Caminiti R, Ielasi A, Vetta G, Parlavecchio A, Rocca DGD, Glauber M, Tespili M, Vizzari G, Micari A. Long-Term Results Following Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients With Severe Aortic Stenosis: A Systematic Review and Meta-Analysis of Randomized Trials. Am J Cardiol 2024; 230:6-13. [PMID: 39173988 DOI: 10.1016/j.amjcard.2024.08.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 07/30/2024] [Accepted: 08/14/2024] [Indexed: 08/24/2024]
Abstract
Transcatheter aortic valve replacement (TAVR) is a safe and effective treatment option for patients with severe aortic stenosis at intermediate or high surgical risk. Results after TAVR in low-risk patients are very encouraging at midterm follow-up, whereas limited long-term (≥3 year) data are available in this subset of patients. This meta-analysis aims to compare the long-term follow-up after TAVR versus surgical aortic valve replacement (SAVR) in low-risk patients. We searched databases up to July 7, 2024 for randomized clinical trials comparing TAVR versus SAVR in low-risk patients (defined as Society of Thoracic Surgeons Predicted Risk of Mortality score <4%) (PROSPERO ID: CRD42023480495). Primary outcome analyzed was all-cause death at a minimum of 3 years of follow-up. The secondary outcomes were cardiovascular death, disabling stroke, myocardial infarction, aortic valve reintervention, endocarditis, new-onset atrial fibrillation, permanent pacemaker implantation, and bioprosthetic valve failure. A total of 3 randomized clinical trials with 2,644 patients (TAVR n = 1,371 patients; SAVR n = 1,273 patients) were included. The follow-up time was 6 ± 2.9 years. TAVR resulted noninferior to SAVR for all-cause death (risk ratio [RR] 0.99, 95% confidence interval [CI] 0.84 to 1.17, p = 0.89, I2 = 28%), cardiovascular death (RR 0.94, 95% CI 0.76 to 1.15, p = 0.54, I2 = 0%), myocardial infarction (RR 1.06, 95% CI 0.71 to 1.57, p = 0.79, I2 = 61%), aortic valve reintervention, endocarditis, and bioprosthetic valve failure. New-onset atrial fibrillation was more common in the SAVR group, whereas permanent pacemaker implantation was more common in the TAVR group. In conclusion, our meta-analysis showed that TAVR is associated with similar long-term outcomes compared with SAVR in selected low-risk patients.
Collapse
|
Comparative Study |
1 |
|
20
|
Tanner R, Krishnamoorthy P, Tang GH, Lerakis S, Anastasius M, Hooda A, Dangas GD, Sharma SK, Kini AS, Khera S. Computed Tomography Geometry of Extremely Undersized SAPIEN 3 Transcatheter Aortic Valves With Balloon Overfilling. JOURNAL OF THE SOCIETY FOR CARDIOVASCULAR ANGIOGRAPHY & INTERVENTIONS 2024; 3:101937. [PMID: 39166166 PMCID: PMC11330925 DOI: 10.1016/j.jscai.2024.101937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 03/07/2024] [Accepted: 03/18/2024] [Indexed: 08/22/2024]
|
brief-report |
1 |
|
21
|
Reardon MJ, Bajwa T, Popma JJ. Commentary: The safety and efficacy of balloon-expandable vs. self-expanding trans-catheter aortic valve replacement in high-risk patients with severe symptomatic aortic stenosis. Front Cardiovasc Med 2023; 10:1295274. [PMID: 38193022 PMCID: PMC10773742 DOI: 10.3389/fcvm.2023.1295274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 12/01/2023] [Indexed: 01/10/2024] Open
|
Comment |
2 |
|
22
|
Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis. J Clin Med 2022; 11:jcm11154570. [PMID: 35956185 PMCID: PMC9369986 DOI: 10.3390/jcm11154570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 07/21/2022] [Accepted: 08/02/2022] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients. METHODS From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients. RESULTS At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p ≤ 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p ≤ 0.001), as well as predicted EOAi (1 vs. 0.9, p ≤ 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p ≤ 0.001), as well as severe PPM (2.9% vs. 8.8%, p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable. CONCLUSIONS In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design.
Collapse
|
|
3 |
|