1
|
The Effects of a New Wireless Non-Adhesive Cardiorespiratory Monitoring Device on the Skin Conditions of Preterm Infants. SENSORS (BASEL, SWITZERLAND) 2024; 24:1258. [PMID: 38400415 PMCID: PMC10892062 DOI: 10.3390/s24041258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 02/08/2024] [Accepted: 02/14/2024] [Indexed: 02/25/2024]
Abstract
AIM The aim of our study was to investigate skin conditions when wearing and removing a novel wireless non-adhesive cardiorespiratory monitoring device for neonates (Bambi-Belt) compared to standard adhesive electrodes. STUDY DESIGN This was a prospective study including preterm neonates requiring cardiorespiratory monitoring. Besides standard electrodes, the infants wore a Bambi Belt for 10 consecutive days. Their skin conditions were assessed using Trans Epidermal Water Loss (TEWL) and the Neonatal Skin Condition Score (NSCS) after daily belt and standard electrode removal. The ∆TEWL was calculated as the difference between the TEWL at the device's location (Bambi-Belt/standard electrode) and the adjacent control skin location, with a higher ∆TEWL indicating skin damage. RESULTS A total of 15 infants (gestational age (GA): 24.1-35.6 wk) were analyzed. The ΔTEWL significantly increased directly after electrode removal (10.95 ± 9.98 g/m2/h) compared to belt removal (5.18 ± 6.71 g/m2/h; F: 8.73, p = 0.004) and after the washout period (3.72 ± 5.46 g/m2/h vs. 1.86 ± 3.35 g/m2/h; F: 2.84, p = 0.09), although the latter did not reach statistical significance. The TEWL was not influenced by prolonged belt wearing. No significant differences in the NSCS score were found between the belt and electrode (OR: 0.69, 95% CI [0.17, 2.88], p = 0.6). CONCLUSION A new wireless non-adhesive device for neonatal cardiorespiratory monitoring was well tolerated in preterm infants and may be less damaging during prolonged wearing.
Collapse
|
2
|
Cellulose Nanocrystal-Based All-3D-Printed Pyro-Piezoelectric Nanogenerator for Hybrid Energy Harvesting and Self-Powered Cardiorespiratory Monitoring toward the Human-Machine Interface. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 36896956 DOI: 10.1021/acsami.2c21680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Biomaterials with spontaneous piezoelectric property are highly emerging in recent times for the generation of electricity from mechanical energy sources that are amply available in nature. In this context, pyroelectricity, an integral property of piezoelectric materials, might be an interesting tool in harvesting thermal energy from the fluctuations of temperature. On the other hand, respiration and heart pulse are the significant human vital signs that can be used for early detection and prevention of cardiorespiratory diseases. Here, we report an all-three-dimensional (3D)-printed pyro-piezoelectric nanogenerator (Py-PNG) based on the most abundant and completely biodegradable biopolymer on earth, i.e., cellulose nanocrystal (CNC) for hybrid (mechanical as well as thermal) energy harvesting, and interestingly, the NG could be used as an e-skin sensor for application in self-powered noninvasive cardiorespiratory monitoring for personal healthcare. Notably, the CNC-based device will be biocompatible and economically advantageous due to its biomaterial-based supremacy and huge availability. This is an original approach with 3D geometrical advancement in designing a NG/sensor, where the unique all-3D-printed manner is adopted, and certainly, it has promising potential in reducing the number of processing steps to required equipment during the multilayer fabrication. The all-3D-printed NG/sensor shows outstanding mechano-thermal energy harvesting performance along with sensitivity and is capable of accurate detection of heart pulse as well as respiration, whenever and whichever required without the need of any battery or an external power supply. In addition, we have also extended its application in demonstrating a smart mask-based breath monitoring system. Thus, the real-time cardiorespiratory monitoring provides notable and fascinating information in medical diagnosis, stepping toward biomedical device development and human-machine interface.
Collapse
|
3
|
Home Cardiorespiratory Monitoring in Infants at Risk for Sudden Infant Death Syndrome (SIDS), Apparent Life-Threatening Event (ALTE) or Brief Resolved Unexplained Event (BRUE). LIFE (BASEL, SWITZERLAND) 2022; 12:life12060883. [PMID: 35743914 PMCID: PMC9227273 DOI: 10.3390/life12060883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 06/07/2022] [Accepted: 06/10/2022] [Indexed: 11/29/2022]
Abstract
Sudden infant death syndrome (SIDS) is defined as the sudden death of an infant younger than one year of age which remains unexplained after a thorough case investigation, including performance of a complete autopsy, examination of the death scene, and review of the clinical history. About 90% of SIDS occur before six months of age, the peak incidence is between two and four months, and the median age for death is elven weeks. The clinical, social, and economic relevance of SIDS, together with the evidence that prevention of this syndrome was possible, has significantly stimulated research into risk factors for the development of SIDS in the hope of being able to introduce new effective preventive measures. This narrative review discusses the potential relationships between apparent life-threatening events (ALTE) or brief resolved unexplained events (BRUE) and SIDS development, and when a home cardiorespiratory monitor is useful for prevention of these conditions. A literature analysis showed that home cardiorespiratory monitoring has been considered a potential method to identify not only ALTE and BRUE but SIDS also. ALTE and BRUE are generally due to underlying conditions that are not detectable in SIDS infants. A true relationship between these conditions has never been demonstrated. Use of home cardiorespiratory monitor is not recommended for SIDS, whereas it could be suggested for children with previous ALTE or severe BRUE or who are at risk of the development of these conditions. However, use of home cardiorespiratory monitors assumes that family members know the advantages and limitations of these devices after adequate education and instruction in their use.
Collapse
|
4
|
A Soft and Skin-Interfaced Smart Patch Based on Fiber Optics for Cardiorespiratory Monitoring. BIOSENSORS 2022; 12:363. [PMID: 35735511 PMCID: PMC9221342 DOI: 10.3390/bios12060363] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Revised: 05/23/2022] [Accepted: 05/23/2022] [Indexed: 06/15/2023]
Abstract
Wearables are valuable solutions for monitoring a variety of physiological parameters. Their application in cardiorespiratory monitoring may significantly impact global health problems and the economic burden related to cardiovascular and respiratory diseases. Here, we describe a soft biosensor capable of monitoring heart (HR) and respiratory (RR) rates simultaneously. We show that a skin-interfaced biosensor based on fiber optics (i.e., the smart patch) is capable of estimating HR and RR by detecting local ribcage strain caused by breathing and heart beating. The system addresses some of the main technical challenges that limit the wide-scale use of wearables, such as the simultaneous monitoring of HR and RR via single sensing modalities, their limited skin compliance, and low sensitivity. We demonstrate that the smart patch estimates HR and RR with high fidelity under different respiratory conditions and common daily body positions. We highlight the system potentiality of real-time cardiorespiratory monitoring in a broad range of home settings.
Collapse
|
5
|
A Wearable Multimodal Sensing System for Tracking Changes in Pulmonary Fluid Status, Lung Sounds, and Respiratory Markers. SENSORS 2022; 22:s22031130. [PMID: 35161876 PMCID: PMC8838360 DOI: 10.3390/s22031130] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 01/23/2022] [Accepted: 01/29/2022] [Indexed: 12/17/2022]
Abstract
Heart failure (HF) exacerbations, characterized by pulmonary congestion and breathlessness, require frequent hospitalizations, often resulting in poor outcomes. Current methods for tracking lung fluid and respiratory distress are unable to produce continuous, holistic measures of cardiopulmonary health. We present a multimodal sensing system that captures bioimpedance spectroscopy (BIS), multi-channel lung sounds from four contact microphones, multi-frequency impedance pneumography (IP), temperature, and kinematics to track changes in cardiopulmonary status. We first validated the system on healthy subjects (n = 10) and then conducted a feasibility study on patients (n = 14) with HF in clinical settings. Three measurements were taken throughout the course of hospitalization, and parameters relevant to lung fluid status—the ratio of the resistances at 5 kHz to those at 150 kHz (K)—and respiratory timings (e.g., respiratory rate) were extracted. We found a statistically significant increase in K (p < 0.05) from admission to discharge and observed respiratory timings in physiologically plausible ranges. The IP-derived respiratory signals and lung sounds were sensitive enough to detect abnormal respiratory patterns (Cheyne–Stokes) and inspiratory crackles from patient recordings, respectively. We demonstrated that the proposed system is suitable for detecting changes in pulmonary fluid status and capturing high-quality respiratory signals and lung sounds in a clinical setting.
Collapse
|
6
|
Major cardiorespiratory events do not increase after immunizations, eye exams, and other stressors in most very low birth weight infants. J Neonatal Perinatal Med 2021; 15:275-282. [PMID: 34459417 DOI: 10.3233/npm-210744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Increased cardiorespiratory events with bradycardia and oxygen desaturation have been reported in very low birthweight (VLBW) infants following stressors such as immunizations. These events are difficult to quantify and may be mild. Our group developed an automated algorithm to analyze bedside monitor data from NICU patients for events with bradycardia and prolonged oxygen desaturation (BDs) and used this to compare BDs 24 hours before and after potentially stressful interventions. METHODS We included VLBW infants from 2012-2017 with data available around at least one of four interventions: two-month immunizations, retinopathy of prematurity (ROP) examinations, ROP therapy, and inguinal hernia surgery. We used a validated algorithm to analyze electrocardiogram heart rate and pulse oximeter saturation data (HR, SpO2) to quantify BD events of HR < 100 beats/minute for≥4 seconds with oxygen desaturation < 80%SpO2 for≥10 seconds. BDs were analyzed 24 hours before and after interventions using Wilcoxon rank-sum tests. RESULTS In 354 of 493 (72%) interventions, BD frequency stayed the same or decreased in the 24 hours after the event. An increase of at least five BD's occurred in 17/146 (12%) after immunizations, 85/290 (29%) after ROP examinations, 4/33 (12%) after ROP therapy, and 3/25 (12%) after hernia surgery. Infants with an increase in BDs after interventions had similar demographics compared to those without. More infants with an increase in BDs following immunizations were on CPAP or caffeine than those without. CONCLUSIONS Most VLBW infants in our cohort had no increase in significant cardiorespiratory events in the 24 hours following potentially stressful interventions.
Collapse
|
7
|
[Cellex in the therapy of patients with complex and central apnea in the early recovery period of ischemic stroke]. Zh Nevrol Psikhiatr Im S S Korsakova 2021; 121:29-32. [PMID: 33908229 DOI: 10.17116/jnevro202112103229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
A variety of structural and functional post-stroke disturbances demands an integrated clinical/diagnostic approach. Persistent hypoxemia due to disturbance of a saturation of blood oxygen in sleep can decrease the effectiveness of neurorehabilitation. In some cases of sleep apnea, the efficiency of continuous positive airway pressure therapy is insufficient and it should be combined with course neuroprotective therapy. Modern approaches to neuroprotective and neuroreparative therapy are considered as the independent direction for treatment of the central sleep apnea syndromes in patients with stroke consequences that is obviously important aspect of secondary prevention of a stroke.
Collapse
|
8
|
Accuracy and Monitoring of Pediatric Early Warning Score (PEWS) Scores Prior to Emergent Pediatric Intensive Care Unit (ICU) Transfer: Retrospective Analysis. JMIR Pediatr Parent 2021; 4:e25991. [PMID: 33547772 PMCID: PMC8078697 DOI: 10.2196/25991] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 02/02/2021] [Accepted: 02/02/2021] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Current approaches to early detection of clinical deterioration in children have relied on intermittent track-and-trigger warning scores such as the Pediatric Early Warning Score (PEWS) that rely on periodic assessment and vital sign entry. There are limited data on the utility of these scores prior to events of decompensation leading to pediatric intensive care unit (PICU) transfer. OBJECTIVE The purpose of our study was to determine the accuracy of recorded PEWS scores, assess clinical reasons for transfer, and describe the monitoring practices prior to PICU transfer involving acute decompensation. METHODS We conducted a retrospective cohort study of patients ≤21 years of age transferred emergently from the acute care pediatric floor to the PICU due to clinical deterioration over an 8-year period. Clinical charts were abstracted to (1) determine the clinical reason for transfer, (2) quantify the frequency of physiological monitoring prior to transfer, and (3) assess the timing and accuracy of the PEWS scores 24 hours prior to transfer. RESULTS During the 8-year period, 72 children and adolescents had an emergent PICU transfer due to clinical deterioration, most often due to acute respiratory distress. Only 35% (25/72) of the sample was on continuous telemetry or pulse oximetry monitoring prior to the transfer event, and 47% (34/72) had at least one incorrectly documented PEWS score in the 24 hours prior to the event, with a score underreporting the actual severity of illness. CONCLUSIONS This analysis provides support for the routine assessment of clinical deterioration and advocates for more research focused on the use and utility of continuous cardiorespiratory monitoring for patients at risk for emergent transfer.
Collapse
|
9
|
Cardiorespiratory Events in Infants Born Preterm during the Transitional Period. J Pediatr 2020; 221:32-38.e2. [PMID: 32446489 DOI: 10.1016/j.jpeds.2020.02.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 01/22/2020] [Accepted: 02/17/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVE To investigate the features of cardiorespiratory events in infants born preterm during the transitional period, and to evaluate whether different neonatal characteristics may correlate with event type, duration, and severity. STUDY DESIGN Infants with gestational age (GA) <32 weeks and/or birth weight <1500 g were enrolled in this observational prospective study. Heart rate (HR) and peripheral oxygen saturation (SpO2) were recorded continuously over the first 72 hours. Cardiorespiratory events of ≥10 seconds were clustered into isolated desaturation (SpO2 <85%), isolated bradycardia (HR <100 bpm or <70% of baseline), or combined desaturation/bradycardia and classified as mild, moderate, or severe. The daily incidences of isolated desaturation, isolated bradycardia, and combined desaturation and bradycardia were analyzed. The effects of relevant clinical variables on cardiorespiratory event type and severity were assessed using generalized estimating equations. RESULTS Among the 1050 events analyzed, isolated desaturations were the most frequent (n = 625) and isolated bradycardias the least common (n = 171). The number of cardiorespiratory events increased significantly from day 1 to day 2 (P = .028). One in 5 events had severe characteristics; event severity was highest for combined desaturation and bradycardia (P < .001). Compared with other event types, the incidence of combined desaturation and bradycardia was inversely correlated with GA (P = .029) and was higher with the use of continuous positive airway pressure (P = .002). The presence of a hemodynamically significant patent ductus arteriosus was associated with the occurrence of isolated desaturations (P = .001) and with a longer duration of cardiorespiratory events (P = .003). CONCLUSIONS Cardiorespiratory events during transition exhibit distinct types, duration, and severity. Neonatal characteristics are associated with the clinical features of these events, indicating that a tailored clinical approach may reduce the hypoxic burden in preterm infants aged 0-72 hours.
Collapse
|
10
|
Diaphragmatic electromyography in preterm infants: The influence of electrode positioning. Pediatr Pulmonol 2020; 55:354-359. [PMID: 31765520 PMCID: PMC7004062 DOI: 10.1002/ppul.24585] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 11/11/2019] [Indexed: 12/04/2022]
Abstract
OBJECTIVE To determine the effect of changing electrode positions on vital signs and respiratory effort parameters measured with transcutaneous electromyography of the diaphragm (dEMG) in preterm infants. METHODS In this observational study, simultaneous dEMG measurements were performed at the standard position and at one alternative electrode position (randomly assigned to lateral, superior, medial, inferior to the standard placement, or dorsal). The activity of the diaphragm was measured for 1 hour at both positions. Main outcome measures were the agreement in heart rate (HR), respiratory rate (RR), and percentage difference in dEMG parameters of respiratory effort (peak and tonic activity, amplitude, area under the curve, and frequency content) between the standard and alternative electrode positions. RESULTS Thirty clinically stable preterm infants (gestational age 30.1 ± 3.0 weeks) with either no or noninvasive respiratory support were included. Agreement in HR was excellent at all positions (ICC > 0.95) while RR agreement showed more diversity (ICC range 0.40-0.86). Mixed modeling of dEMG parameters revealed that medial and inferior placement measured the weakest signals (median 75.5% and 64.5% lower dEMG amplitude). Lateral electrode placement showed the highest similarity to standard positioning (median 23.5% lower amplitude). CONCLUSION Measuring HR showed high similarity at all positions. However, registration of RR and respiratory effort is clearly influenced by the electrode position. Electrodes in the same transversal plane as the diaphragm, and at sufficient distance from each other, provide the best agreement with the standard positioning.
Collapse
|
11
|
Initial Experience and Usage Patterns With the Owlet Smart Sock Monitor in 47,495 Newborns. Glob Pediatr Health 2017; 4:2333794X17742751. [PMID: 29230431 PMCID: PMC5718309 DOI: 10.1177/2333794x17742751] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 10/20/2017] [Indexed: 11/25/2022] Open
Abstract
We report the largest experience, to our knowledge, of home cardiorespiratory monitoring in 47,495 newborns using the novel Owlet Smart Sock (OSS) technology (October 2015 to May 2017). On average, 47,495 newborns were monitored for 6 months, 4.5 d/wk, 9.9 h/d. Continuous readings of oxygen saturation and heart rate were obtained from 39,626 full-term newborns. OSS users were likely first-time parents in their 30s with at least a college degree; 37% had a healthcare professional in the family; and 28% were at or below median income level per the US Census Bureau. “Peace of mind” was the reason to own an OSS in 75%, and 82% of parents followed Safe Sleep Guidelines. A total of 94% of parents reported a better quality of sleep. The fast and continuous pace of device adoption and reported experience suggest excellent parental acceptance of the OSS. Prospective studies are warranted to further evaluate its applications in the high-risk newborn population.
Collapse
|
12
|
Association between gastroesophageal reflux and pathologic apneas in infants: a systematic review. Neurogastroenterol Motil 2014; 26:1527-38. [PMID: 25080836 DOI: 10.1111/nmo.12405] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2014] [Accepted: 06/27/2014] [Indexed: 12/13/2022]
Abstract
BACKGROUND In infants, apneas can be centrally mediated, obstructive or both and have been proposed to be gastroesophageal reflux (GER) induced. Evidence for this possible association has never been systematically reviewed. PURPOSE To perform a systematic review using PubMed, EMBASE and Cochrane databases to determine whether an association between GER and apnea in infants exists. Studies with n ≥ 10 infants, aged <12 months, were included. GER had to be studied by pH-metry or pH-impedancemetry. GER episodes were defined as pH <4 for ≥ 5 s and/or a drop of >50% of baseline in impedance signal in distal channels. An apneic event was defined as a cessation of breathing for >20 s, or ≥ 10 s with hypoxemia or bradycardia. An epoch of ≤ 2 min was used to define temporal relation between GER and apnea. Methodological quality of studies was assessed with Newcastle Ottawa Scale (NOS). Of 1959 abstracts found, 6 articles met the inclusion criteria. All studies had poor methodological quality. A total of 289 infants were included. The temporal association of GER followed by apnea was assessed in all studies, with epochs varying from 10 s to 2 min. One study found an increase of apneic events after GER, the remaining 5 studies did not find an association. Two studies assessed apnea followed by GER as well, but did not find sufficient evidence for association. This systematic review showed insufficient evidence for an association between GER and apneas in infants. High quality studies using uniform inclusion criteria, definitions according to accepted guidelines, and patient relevant outcome measures are needed.
Collapse
|
13
|
Abstract
Because signs of nocturnal seizures can overlap with sleep respiratory events, clinicians can have difficulty distinguishing abnormal events related to sleep disorders from epileptic seizures. We describe the case of a 3-year-old child presenting with ictal electroencephalographic (EEG) activity associated with a particular form of atypical obstructive sleep apnea, characterized by increased respiratory rate, paradoxical breathing, desaturations, and tonic-dystonic posture associated with movement artifacts. Following cardiorespiratory polysomnography, the patient was initially misdiagnosed as having severe obstructive sleep apnea syndrome.
Collapse
|
14
|
Abstract
BACKGROUND The relationship between sleep and mood regulation is well known, and some reports suggest a key role of sleep-related breathing disorders (SRBD) in the development of the symptomatology of depression, even if no conclusive data are actually found in the clinical literature. The aim of this study was to assess the relationship between SRBD and depressive symptoms in a population of school-aged children. METHODS The study population comprised 94 children affected by SRBD and 107 healthy children. To identify the severity of SRBD, an overnight respiratory evaluation was performed. All subjects filled out the Italian version of the Children Depression Inventory (CDI) to screen for the presence of depressive symptoms. RESULTS The group with SRBD showed higher CDI scores than the group without SRBD, with a positive correlation found between CDI scores, apnea-hypopnea index, and oxygen desaturation index values. Logistic regression showed that an apnea-hypopnea index ≥ 3 and an oxygen desaturation index ≥ 1 could be risk factors for development of depressive symptoms. According to receiver-operating characteristic curve analysis, the cutoff point for the apnea-hypopnea index that could cause a pathological CDI score (≥19) was >5.66, and the cutoff point for the oxygen desaturation index was >4.2. The limitations of this study are that our data are derived from one single psychometric test and not from a complete psychiatric evaluation, and our subjects came from a small group in southern Italy. CONCLUSION Our results suggest the importance of mood assessment in children affected by SRBD.
Collapse
|