1
|
Plunkett BA, Weiner SJ, Saade GR, Belfort MA, Blackwell SC, Thorp JM, Tita ATN, Miller RS, McKenna DS, Chien EKS, Rouse DJ, El-Sayed YY, Sorokin Y, Caritis SN. Maternal Diabetes and Intrapartum Fetal Electrocardiogram. Am J Perinatol 2024; 41:e14-e21. [PMID: 35381609 PMCID: PMC9532457 DOI: 10.1055/a-1817-5788] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVE Fetal electrocardiogram (ECG) ST changes are associated with fetal cardiac hypoxia. Our objective was to evaluate ST changes by maternal diabetic status and stage of labor. METHODS This was a secondary analysis of a multicentered randomized-controlled trial in which laboring patients with singleton gestations underwent fetal ECG scalp electrode placement and were randomly assigned to masked or unmasked ST-segment readings. Our primary outcome was the frequency of fetal ECG tracings with ST changes by the stage of labor. ECG tracings were categorized into mutually exclusive groups (ST depression, ST elevation without ST depression, or no ST changes). We compared participants with DM, gestational diabetes mellitus (GDM), and no DM. RESULTS Of the 5,436 eligible individuals in the first stage of labor (95 with pregestational DM and 370 with GDM), 4,427 progressed to the second stage. ST depression occurred more frequently in the first stage of labor in participants with pregestational DM (15%, adjusted odds ratio [aOR] 2.20, 95% confidence interval [CI] 1.14-4.24) and with GDM (9.5%, aOR 1.51, 95% CI 1.02-2.25) as compared with participants without DM (5.7%). The frequency of ST elevation was similar in participants with pregestational DM (33%, aOR 0.79, 95% CI 0.48-1.30) and GDM (33.2%, aOR 0.91, 95% CI 0.71-1.17) as compared with those without DM (34.2%). In the second stage, ST depression did not occur in participants with pregestational DM (0%) and occurred more frequently in participants with GDM (3.5%, aOR 2.01, 95% CI 1.02-3.98) as compared with those without DM (2.0%). ST elevation occurred more frequently in participants with pregestational DM (30%, aOR 1.81, 95% CI 1.02-3.22) but not with GDM (19.0%, aOR 1.06, 95% CI 0.77-1.47) as compared with those without DM (17.8%). CONCLUSION ST changes in fetal ECG occur more frequently in fetuses of diabetic mothers during labor. CLINICALTRIALS gov number, NCT01131260. PRECIS ST changes in fetal ECG, a marker of fetal cardiac hypoxia, occur more frequently in fetuses of diabetic parturients. KEY POINTS · Fetal hypertrophic cardiomyopathy (HCM) and cardiac dysfunction occur frequently among fetuses of diabetic patients.. · Fetal ECG changes such as ST elevation and depression reflect cardiac hypoxia.. · Fetuses of diabetic patients demonstrate a higher prevalence of fetal ECG tracings with ST changes..
Collapse
|
2
|
Hussain NM, O'Halloran M, McDermott B, Elahi MA. Fetal monitoring technologies for the detection of intrapartum hypoxia - challenges and opportunities. Biomed Phys Eng Express 2024; 10:022002. [PMID: 38118183 DOI: 10.1088/2057-1976/ad17a6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 12/20/2023] [Indexed: 12/22/2023]
Abstract
Intrapartum fetal hypoxia is related to long-term morbidity and mortality of the fetus and the mother. Fetal surveillance is extremely important to minimize the adverse outcomes arising from fetal hypoxia during labour. Several methods have been used in current clinical practice to monitor fetal well-being. For instance, biophysical technologies including cardiotocography, ST-analysis adjunct to cardiotocography, and Doppler ultrasound are used for intrapartum fetal monitoring. However, these technologies result in a high false-positive rate and increased obstetric interventions during labour. Alternatively, biochemical-based technologies including fetal scalp blood sampling and fetal pulse oximetry are used to identify metabolic acidosis and oxygen deprivation resulting from fetal hypoxia. These technologies neither improve clinical outcomes nor reduce unnecessary interventions during labour. Also, there is a need to link the physiological changes during fetal hypoxia to fetal monitoring technologies. The objective of this article is to assess the clinical background of fetal hypoxia and to review existing monitoring technologies for the detection and monitoring of fetal hypoxia. A comprehensive review has been made to predict fetal hypoxia using computational and machine-learning algorithms. The detection of more specific biomarkers or new sensing technologies is also reviewed which may help in the enhancement of the reliability of continuous fetal monitoring and may result in the accurate detection of intrapartum fetal hypoxia.
Collapse
|
3
|
DiPietro JA, Bai J, Sgambati FP, Henderson JL, Watson H, Raghunathan RS, Pien GW. Fetal heart rate responses to maternal sleep-disordered breathing. Am J Obstet Gynecol 2023; 228:459.e1-459.e8. [PMID: 36183777 PMCID: PMC10050230 DOI: 10.1016/j.ajog.2022.09.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 09/22/2022] [Accepted: 09/24/2022] [Indexed: 11/23/2022]
Abstract
BACKGROUND Maternal sleep-disordered breathing is associated with adverse pregnancy outcomes and is considered to be deleterious to the developing fetus. Maternal obesity potentiates sleep-disordered breathing, which, in turn, may contribute to the effect of maternal obesity on adverse fetal outcomes. However, only a few empirical studies have evaluated the contemporaneous effects of maternal sleep-disordered breathing events on fetal well-being. These events include apnea and hypopnea with accompanying desaturations in oxyhemoglobin. OBJECTIVE This study aimed to reconcile contradictory findings on the associations between maternal apnea or hypopnea events and clinical indicators of fetal compromise. It also sought to broaden the knowledge base by examining the fetal heart rate and heart rate variability before, during, and after episodes of maternal apnea or hypopnea. To accomplish this, we employed overnight polysomnography, the gold standard for ascertaining maternal sleep-disordered breathing, and synchronized it with continuous fetal electrocardiography. STUDY DESIGN A total of 84 pregnant women with obesity (body mass index >30 kg/m2) participated in laboratory-based polysomnography with digitized fetal electrocardiography recordings during or near 36 weeks of gestation. Sleep was recorded, on average, for 7 hours. Decelerations in fetal heart rate were identified. Fetal heart rate and heart rate variability were quantified before, during, and after each apnea or hypopnea event. Event-level intensity (desaturation magnitude, duration, and nadir O2 saturation level) and person-level characteristics based on the full overnight recording (apnea-hypopnea index, mean O2 saturation, and O2 saturation variability) were analyzed as potential moderators using linear mixed effects models. RESULTS A total of 2936 sleep-disordered breathing events were identified, distributed among all but 2 participants. On average, participants exhibited 8.7 episodes of apnea or hypopnea per hour (mean desaturation duration, 19.1 seconds; mean O2 saturation nadir, 86.6% per episode); nearly half (n=39) of the participants met the criteria for obstructive sleep apnea. Only 45 of 2936 apnea or hypopnea events were followed by decelerations (1.5%). Conversely, most (n=333, 88%) of the 378 observed decelerations, including the prolonged ones, did not follow an apnea or a hypopnea event. Maternal sleep-disordered breathing burden, body mass index, and fetal sex were unrelated to the number of decelerations. Fetal heart rate variability increased during events of maternal apnea or hypopnea but returned to initial levels soon thereafter. There was a dose-response association between the size of the increase in fetal heart rate variability and the maternal apnea-hypopnea index, event duration, and desaturation depth. Longer desaturations were associated with a decreased likelihood of the variability returning to baseline levels after the event. The mean fetal heart rate did not change during episodes of maternal apnea or hypopnea. CONCLUSION Episodes of maternal sleep apnea and hypopnea did not evoke decelerations in the fetal heart rate despite the predisposing risk factors that accompany maternal obesity. The significance of the modest transitory increase in fetal heart rate variability in response to apnea and hypopnea episodes is not clear but may reflect compensatory, delimited autonomic responses to momentarily adverse conditions. This study found no evidence that episodes of maternal sleep-disordered breathing pose an immediate threat, as reflected in fetal heart rate responses, to the near-term fetus.
Collapse
|
4
|
Nakatani S, Yamamoto K, Ohtsuki T. Fetal Arrhythmia Detection Based on Labeling Considering Heartbeat Interval. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 10:bioengineering10010048. [PMID: 36671621 PMCID: PMC9855115 DOI: 10.3390/bioengineering10010048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 12/20/2022] [Accepted: 12/26/2022] [Indexed: 12/31/2022]
Abstract
Arrhythmia is one of the causes of sudden infant death, and it is very important to detect fetal arrhythmia for fetal well-being. Fetal electrocardiogram (FECG) is one of the methods to detect a heartbeat. Fetal arrhythmia can be detected based on the heartbeat detection results from FECG signals such as heartbeat intervals. However, the accuracy of arrhythmia detection easily degrades depending on the accuracy of heartbeat detection. In this paper, we propose a deep learning-based fetal arrhythmia detection method using FECG signals. Recently, arrhythmia detection methods using adult ECG signals have achieved a high arrhythmia detection accuracy based on deep learning. Motivated by this fact, in the proposed method, the acquired FECG signals are segmented, and the segments are input into a deep learning model that classifies them into normal or arrhythmia ones. Based on the classification results of multiple segments, a subject is judged as a healthy or arrhythmia subject. Each segment of the training data is divided into three categories based on the estimated heartbeat interval: (i) normal, (ii) arrhythmia, and (iii) a segment that could be both normal and arrhythmic. Only segments labeled as normal or arrhythmia are used for training a deep learning model to achieve a higher classification accuracy of the model. Through these procedures, the proposed method detects fetal arrhythmia with fewer effects of heartbeat detection results. The experimental results show that the proposed method achieves 96.2% accuracy, 100% specificity, and 100% recall, improving the values of conventional methods based on heartbeat detection and feature detection.
Collapse
|
5
|
Reis‐de‐Carvalho C, Nogueira P, Ayres‐de‐Campos D. Quality of fetal heart rate monitoring with transabdominal fetal ECG during maternal movement in labor: A prospective study. Acta Obstet Gynecol Scand 2022; 101:1269-1275. [PMID: 35959521 PMCID: PMC9812089 DOI: 10.1111/aogs.14434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 07/10/2022] [Accepted: 07/13/2022] [Indexed: 01/07/2023]
Abstract
INTRODUCTION Transabdominal electrocardiographic (TAfECG) acquisition of fetal heart rate (FHR) signals has recently been introduced into leading commercial cardiotocographic (CTG) monitors. Continuous wireless transmission of signals has raised the possibility of the technology being used during maternal mobilization in labor. This study aims to evaluate signal quality and accuracy of TAfECG acquisition of FHR signals during static and active maternal positions in labor when compared with Doppler signals and with the gold-standard method of fetal scalp electrode (FSE). MATERIAL AND METHODS A total of 76 women with singleton term pregnancies in the active first stage of labor had simultaneously acquired FHR with TAfECG, Doppler, and FSE. Participants were asked to complete a supervised mobilization scheme, comprising five sequential 10-min periods of lying down, standing, sitting, walking, and rocking on the birthing ball. The three FHR signals were compared, defining signal loss as the percentage of signals under 20 bpm or exceeding 250 bpm and accuracy as the difference with FSE values. Computer analysis was used to quantify variability, accelerations, and decelerations. Static labor positions (lying down, standing, and sitting) were compared with active labor positions (walking and rocking on the birthing ball). RESULTS Average signal loss was 5.3% with TAfECG (3.2% in static and 7.4% in active positions) and 15.5% with Doppler (8.3% in static and 30.7% in active positions). Average accuracy was 3.5 bpm with TAfECG (1.9 bpm in static and 5.04 bpm in active positions) and 13.9 bpm with Doppler (3.2 bpm in static and 24.7 bpm in active positions). Average variability was similar with TAfECG and FSE in static positions but significantly higher with TAfECG in active positions (23.6 vs. 13.5 bpm, p < 0.001). CONCLUSIONS In static labor positions, TAfECG provides a low signal loss, similar to that obtained with FSE, and a good signal accuracy, so the technique can be considered reliable when the mother is lying down, standing, or sitting. During maternal movement, TAfECG causes an artificial increase in FHR variability, which can cause false reassurance regarding fetal oxygenation. Doppler signals are unreliable during maternal movements.
Collapse
|
6
|
Blix E, Eskild A, Skau I, Grytten J. The impact of the introduction of intrapartum fetal ECG ST segment analysis. A population study. Acta Obstet Gynecol Scand 2022; 101:809-818. [PMID: 35288935 PMCID: PMC9564625 DOI: 10.1111/aogs.14347] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 02/17/2022] [Accepted: 02/25/2022] [Indexed: 11/29/2022]
Abstract
INTRODUCTION ST segment analysis (STAN) of the fetal electrocardiogram was introduced as an adjunct to cardiotocography for intrapartum fetal monitoring 30 years ago. We examined the impact of the introduction of STAN on changes in the occurrence of fetal and neonatal deaths, Apgar scores of <7 at 5 min, intrapartum cesarean sections, and instrumental vaginal deliveries while controlling for time- and hospital-specific trends and maternal risk factors. MATERIAL AND METHODS Data were retrieved from the Medical Birth Registry of Norway from 1985 to 2014. Individual data were linked to the Education Registry and the Central Person Registry. The study sample included 1 132 022 singleton births with a gestational age of 36 weeks or beyond. Information about the year of STAN introduction was collected from every birth unit in Norway using a questionnaire. Our data structure consisted of a hospital-year panel. We applied a linear probability model with hospital-fixed effects and with adjustment for potentially confounding factors. The prevalence of the outcomes before and after the introduction of STAN were compared within each birth unit. RESULTS In total, 23 birth units, representing 76% of all births in Norway, had introduced the STAN technology. During the study period, stillbirths declined from 2.6 to 1.9 per 1000 births, neonatal deaths declined from 1.7 to 0.7 per 1000 live births, babies with Apgar score <7 at 5 min after birth increased from 7.4 to 9.5 per 1000 births, intrapartum cesarean sections increased from 6.4% to 9.5%, and instrumental vaginal deliveries increased from 7.8% to 10.9%. Our analyses found that the introduction of STAN was not associated with the decline in proportion of stillbirths (p =0.76) and neonatal deaths (p =0.76) or with the increase in intrapartum cesarean sections (p =0.92) and instrumental vaginal deliveries (p =0.78). However, it was associated with the increased occurrence of Apgar score <7 at 5 min (p =0.01). CONCLUSIONS There is no evidence that the introduction of STAN contributed to changes in the rates of stillbirths, neonatal deaths, intrapartum cesarean sections, or instrumental vaginal deliveries. There was an association between the introduction of STAN and a small increase in neonates with low Apgar scores.
Collapse
|
7
|
Fotiadou E, van Sloun RJG, van Laar JOEH, Vullings R. A dilated inception CNN-LSTM network for fetal heart rate estimation. Physiol Meas 2021; 42. [PMID: 33853039 DOI: 10.1088/1361-6579/abf7db] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Accepted: 04/14/2021] [Indexed: 01/16/2023]
Abstract
Objective. Fetal heart rate (HR) monitoring is routinely used during pregnancy and labor to assess fetal well-being. The noninvasive fetal electrocardiogram (ECG), obtained by electrodes on the maternal abdomen, is a promising alternative to standard fetal monitoring. Subtraction of the maternal ECG from the abdominal measurements results in fetal ECG signals, in which the fetal HR can be determined typically through R-peak detection. However, the low signal-to-noise ratio and the nonstationary nature of the fetal ECG make R-peak detection a challenging task.Approach. We propose an alternative approach that instead of performing R-peak detection employs deep learning to directly determine the fetal HR from the extracted fetal ECG signals. We introduce a combination of dilated inception convolutional neural networks (CNN) with long short-term memory networks to capture both short-term and long-term temporal dynamics of the fetal HR. The robustness of the method is reinforced by a separate CNN-based classifier that estimates the reliability of the outcome.Main results. Our method achieved a positive percent agreement (within 10% of the actual fetal HR value) of 97.3% on a dataset recorded during labor and 99.6% on set-A of the 2013 Physionet/Computing in Cardiology Challenge exceeding top-performing state-of-the-art algorithms from the literature.Significance. The proposed method can potentially improve the accuracy and robustness of fetal HR extraction in clinical practice.
Collapse
|
8
|
Evaluation of an external fetal electrocardiogram monitoring system: a randomized controlled trial. Am J Obstet Gynecol 2020; 223:244.e1-244.e12. [PMID: 32087146 DOI: 10.1016/j.ajog.2020.02.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 02/02/2020] [Accepted: 02/10/2020] [Indexed: 11/21/2022]
Abstract
OBJECTIVE The objective of the study was to compare interpretability of 2 intrapartum abdominal fetal heart rate-monitoring strategies. We hypothesized that an external fetal electrocardiography monitoring system, a newer technology using wireless abdominal pads, would generate more interpretable fetal heart rate data compared with standard external Doppler fetal heart rate monitoring (standard external monitoring). STUDY DESIGN We conducted a randomized controlled trial at 4 Utah hospitals. Patients were enrolled at labor admission and randomized in blocks based on body mass index to fetal electrocardiography or standard external monitoring. Two reviewers, blinded to study allocation, reviewed each fetal heart rate tracing. The primary outcome was the percentage of interpretable minutes of fetal heart rate tracing. An interpretable minute was defined as >25% fetal heart rate data present and no more than 25% continuous missing fetal heart rate data or artifact present. Secondary outcomes included the percentage of interpretable minutes of fetal heart rate tracing obtained while on study device only, the number of device adjustments required intrapartum, clinical outcomes, and patient/provider device satisfaction. We determined that 100 patients per arm (200 total) would be needed to detect a 5% difference in interpretability with 95% power. RESULTS A total of 218 women were randomized, 108 to fetal electrocardiography and 110 to standard external monitoring. Device setup failure occurred more often in the fetal electrocardiography group (7.5% [8 of 107] vs 0% [0 of 109] for standard external monitoring). There were no differences in the percentage of interpretable tracing between the 2 groups. However, fetal electrocardiography produced more interpretable fetal heart rate tracing in subjects with a body mass index ≥30 kg/m2. When considering the percentage of interpretable minutes of fetal heart rate tracing while on study device only, fetal electrocardiography outperformed standard external monitoring for all subjects, regardless of maternal body mass index. Maternal demographics and clinical outcomes were similar between arms. In the fetal electrocardiography group, more device changes occurred compared with standard external monitoring (51% vs 39%), but there were fewer nursing device adjustments (2.9 vs 6.2 mean adjustments intrapartum, P < .01). There were no differences in physician device satisfaction scores between groups, but fetal electrocardiography generated higher patient satisfaction scores. CONCLUSION Fetal electrocardiography performed similarly to standard external monitoring when considering percentage of interpretable tracing generated in labor. Furthermore, patients reported overall greater satisfaction with fetal electrocardiography in labor. Fetal electrocardiography may be particularly useful in patients with a body mass index ≥30 kg/m2.
Collapse
|
9
|
Vullings R, van Laar JOEH. Non-invasive Fetal Electrocardiography for Intrapartum Cardiotocography. Front Pediatr 2020; 8:599049. [PMID: 33363064 PMCID: PMC7755891 DOI: 10.3389/fped.2020.599049] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 11/19/2020] [Indexed: 11/19/2022] Open
Abstract
Fetal monitoring is important to diagnose complications that can occur during pregnancy. If detected timely, these complications might be resolved before they lead to irreversible damage. Current fetal monitoring mainly relies on cardiotocography, the simultaneous registration of fetal heart rate and uterine activity. Unfortunately, the technology to obtain the cardiotocogram has limitations. In current clinical practice the fetal heart rate is obtained via either an invasive scalp electrode, that poses risks and can only be applied during labor and after rupture of the fetal membranes, or via non-invasive Doppler ultrasound technology that is inaccurate and suffers from loss of signal, in particular in women with high body mass, during motion, or in preterm pregnancies. In this study, transabdominal electrophysiological measurements are exploited to provide fetal heart rate non-invasively and in a more reliable manner than Doppler ultrasound. The performance of the fetal heart rate detection is determined by comparing the fetal heart rate to that obtained with an invasive scalp electrode during intrapartum monitoring. The performance is gauged by comparing it to performances mentioned in literature on Doppler ultrasound and on two commercially-available devices that are also based on transabdominal fetal electrocardiography.
Collapse
|
10
|
Amer-Wåhlin I, Ugwumadu A, Yli BM, Kwee A, Timonen S, Cole V, Ayres-de-Campos D, Roth GE, Schwarz C, Ramenghi LA, Todros T, Ehlinger V, Vayssiere C. Fetal electrocardiography ST-segment analysis for intrapartum monitoring: a critical appraisal of conflicting evidence and a way forward. Am J Obstet Gynecol 2019; 221:577-601.e11. [PMID: 30980794 DOI: 10.1016/j.ajog.2019.04.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 03/31/2019] [Accepted: 04/01/2019] [Indexed: 10/27/2022]
Abstract
BACKGROUND In the past century, some areas of obstetric including intrapartum care have been slow to benefit from the dramatic advances in technology and medical care. Although fetal heart rate monitoring (cardiotocography) became available a half century ago, its interpretation often differs between institutions and countries, its diagnostic accuracy needs improvement, and a technology to help reduce the unnecessary obstetric interventions that have accompanied the cardiotocography is urgently needed. STUDY DESIGN During the second half of the 20th century, key findings in animal experiments captured the close relationship between myocardial glycogenolysis, myocardial workload, and ST changes, thus demonstrating that ST waveform analysis of the fetal electrocardiogram can provide information on oxygenation of the fetal myocardium and establishing the physiological basis for the use of electrocardiogram in intrapartum fetal surveillance. RESULTS Six randomized controlled trials, 10 meta-analyses, and more than 20 observational studies have evaluated the technology developed based on this principle. Nonetheless, despite this intensive assessment, differences in study protocols, inclusion criteria, enrollment rates, clinical guidelines, use of fetal blood sampling, and definitions of key outcome parameters, as well as inconsistencies in randomized controlled trial data handling and statistical methodology, have made this voluminous evidence difficult to interpret. Enormous resources spent on randomized controlled trials have failed to guarantee the generalizability of their results to other settings or their ability to reflect everyday clinical practice. CONCLUSION The latest meta-analysis used revised data from primary randomized controlled trials and data from the largest randomized controlled trials from the United States to demonstrate a significant reduction of metabolic acidosis rates by 36% (odds ratio, 0.64; 95% confidence interval, 0.46-0.88) and operative vaginal delivery rates by 8% (relative risk, 0.92; 95% confidence interval, 0.86-0.99), compared with cardiotocography alone.
Collapse
|
11
|
Modanlou HD. Edward H. Hon, MD (1917-2006): A scientist, inventor, academician and the pioneer for the development of electronic fetal heart rate monitoring. J Obstet Gynaecol Res 2019; 45:2364-2368. [PMID: 31565824 DOI: 10.1111/jog.14123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Accepted: 08/29/2019] [Indexed: 11/30/2022]
Abstract
AIMS To describe the professional life of Edward H. Hon, MD, and the course of his academic career for the development of electronic fetal heart rate (FHR) monitoring. METHODS Review of archives at the Loma Linda University related to Dr Hon's early education and medical school training, his postgraduate training at Yale University, his faculty appointments at Yale University, University of Southern California and his research accomplishment related to electronic FHR monitoring. RESULTS Primarily, Dr Hon advanced the clinical application of the electronic FHR monitoring, particularly during labor and delivery. Dr Hon also defined significance of FHR patterns based on years of clinical studies and astute observations. CONCLUSION Currently, electronic FHR monitoring, during pregnancy and labor/delivery, has a universal application. Dr Hon's research contribution on FHR monitoring, and its impact for the welfare of mother and her unborn child, is well recognized.
Collapse
|
12
|
Significant reduction in umbilical artery metabolic acidosis after implementation of intrapartum ST waveform analysis of the fetal electrocardiogram. Am J Obstet Gynecol 2019; 221:63.e1-63.e13. [PMID: 30826340 DOI: 10.1016/j.ajog.2019.02.049] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 01/17/2019] [Accepted: 02/22/2019] [Indexed: 11/24/2022]
Abstract
BACKGROUND Although the evidence regarding the benefit of using ST waveform analysis of the fetal electrocardiogram is conflicting, ST waveform analysis is considered as adjunct to identify fetuses at risk for asphyxia in our center. Most randomized controlled trials and meta-analyses have not shown a significant decrease in umbilical metabolic acidosis, while some observational studies have shown a gradual decrease of this outcome over a longer period of time. Observational studies can give more insight into the effect of implementation of the ST technology in daily clinical practice. OBJECTIVE To evaluate the change in frequency of perinatal intervention and adverse neonatal outcome after the implementation of ST waveform analysis of the fetal electrocardiogram from 2000 to 2013. STUDY DESIGN This retrospective longitudinal study was conducted in a tertiary referral center. A total of 19,664 medium- and high-risk singleton pregnancies with fetuses in cephalic presentation, a gestational age of ≥36 weeks, and the intention to deliver vaginally were included. ST waveform analysis of the fetal electrocardiogram was implemented in the year 2000 and by 2010 all deliveries were monitored using this technology. Data were collected on the following perinatal outcomes: fetal blood sampling, mode of delivery, umbilical cord blood gases, Apgar scores, neonatal encephalopathy, and perinatal death. Longitudinal trend analysis was used to detect changes over time in all deliveries monitored by cardiotocography either alone or in adjunct to ST waveform analysis of the fetal electrocardiogram. Logistic regression was used to correct for possible confounders. RESULTS The umbilical artery metabolic acidosis rate declined from 2.5% (average rate of 2000 + 2001 + 2002) to 0.4% (average of 2011 + 2012 + 2013) (P < .001), which represents an 84% decrease. This decrease largely occurred between 2006 and 2008, during the Dutch randomized trial on fetal electrocardiogram ST waveform analysis. At this time, approximately 20% of deliveries were monitored using this method. Furthermore, there were significant reductions in fetal blood sampling rate (P < .001). Overall cesarean and vaginal instrumental deliveries decreased significantly (P < .001), but not for fetal distress. There were no changes in the Apgar scores. The incidence of neonatal encephalopathy was significantly lower in the second part of the study (odds ratio 0.39, 95% confidence interval 0.17-0.89). CONCLUSION There was an 84% decrease in the incidence of umbilical artery metabolic acidosis in all deliveries between 2000 and 2013. The neonatal encephalopathy rate, fetal blood sampling rate, and the total number of cesarean and vaginal instrumental deliveries also decreased.
Collapse
|
13
|
Kapaya H, Dimelow ER, Anumba D. Women's experience of wearing a portable fetal-electrocardiogram device to monitor small-for-gestational age fetus in their home environment. ACTA ACUST UNITED AC 2019; 14:1745506518785620. [PMID: 29968515 PMCID: PMC6048658 DOI: 10.1177/1745506518785620] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Objective: To determine the acceptability, to women, of wearing a portable fetal
electrocardiogram recording device at different stages of pregnancy and to
gain insight into their experience of its use for long-periods of monitoring
of small-for-gestational fetuses in the home environment. Methods: A qualitative study using both a questionnaire and focus group involving
women with singleton pregnancy >24 weeks gestation, no evidence of fetal
malformation and an estimated fetal weight below 10th gestational centile on
ultrasound scan. Fetal heart rate recordings were collected for up to
20 h. Results: In total, 59 questionnaires were completed; 35 after wearing the monitor for
the first time and an additional 24 from the women who wore the device for a
second time. Six women participated in the focus group; the principal theme
identified related to the practicality of the fetal electrocardiogram
device. Other themes identified were the discomfort that resulted from
wearing the monitor and the reassurance provided in knowing that the baby’s
heart rate was being monitored. Conclusion: Long-term ambulatory fetal electrocardiogram monitoring is an acceptable
method of monitoring small-for-gestational fetuses. Overall, women concluded
that benefits of wearing the device outweighed any discomfort it caused.
Collapse
|
14
|
Joutsiniemi T, Ekblad U, Rosén KG, Timonen S. Waveform analysis of the fetal ECG in labor in patients with intrahepatic cholestasis of pregnancy. J Obstet Gynaecol Res 2018; 45:306-312. [PMID: 30203501 DOI: 10.1111/jog.13812] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Accepted: 08/10/2018] [Indexed: 12/27/2022]
Abstract
AIM Intrahepatic cholestasis of pregnancy (ICP) is reported to be associated with an increased risk of sudden fetal death. The possible mechanism is thought to be cardiac arrhythmia. Prolonged QT interval of the electrocardiogram (ECG) is associated with arrhytmogenic events. The aim of the study was to compare the fetal ECG QT interval during labor in pregnancies complicated with ICP to healthy controls. METHODS The fetal ECG and QT interval was reviewed retrospectively. The intrapartum QT interval was measured in 61 fetuses born to mothers with ICP and in a control group of similar size. The corrected QT interval (QTc) was calculated using Bazett's formula: QT/√RR. The occurrence of ST segment depression was also included in the analysis. RESULTS The groups were similar regarding to maternal age, parity, BMI, gestational age and smoking habits. The rate of labor induction was significantly higher in ICP patients (P < 0.001). The QTc at the beginning and the end of recording was analyzed and there were no significant differences in these values between the ICP patients and healthy controls (P = 0.467). Most ICP patients used ursodeoxycholic acid (UDCA) for mediation. We analyzed separately patients who had elevated liver enzymes before labor. No significant differences in the QTc were noted in these patients either. Nor were there any significant ST depressions in ICP patients. CONCLUSIONS The etiology of adverse perinatal outcome and even sudden fetal death in ICP is still controversial. No differences in QTc intervals and ST waveforms during labor were found in our study material.
Collapse
|
15
|
Minato T, Ito T, Kasahara Y, Ooshio S, Fushima T, Sekimoto A, Takahashi N, Yaegashi N, Kimura Y. Relationship Between Short Term Variability (STV) and Onset of Cerebral Hemorrhage at Ischemia-Reperfusion Load in Fetal Growth Restricted (FGR) Mice. Front Physiol 2018; 9:478. [PMID: 29867536 PMCID: PMC5968166 DOI: 10.3389/fphys.2018.00478] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Accepted: 04/16/2018] [Indexed: 12/14/2022] Open
Abstract
Fetal growth restriction (FGR) is a risk factor exacerbating a poor neurological prognosis at birth. A disease exacerbating a poor neurological prognosis is cerebral palsy. One of the cause of this disease is cerebral hemorrhage including intraventricular hemorrhage. It is believed to be caused by an inability to autoregulate cerebral blood flow as well as immaturity of cerebral vessels. Therefore, if we can evaluate the function of autonomic nerve, cerebral hemorrhage risk can be predicted beforehand and appropriate delivery management may be possible. Here dysfunction of autonomic nerve in mouse FGR fetuses was evaluated and the relationship with cerebral hemorrhage incidence when applying hypoxic load to resemble the brain condition at the time of delivery was examined. Furthermore, FGR incidence on cerebral nerve development and differentiation was examined at the gene expression level. FGR model fetuses were prepared by ligating uterine arteries to reduce placental blood flow. To compare autonomic nerve function in FGR mice with that in control mice, fetal short term variability (STV) was measured from electrocardiograms. In the FGR group, a significant decrease in the STV was observed and dysfunction of cardiac autonomic control was confirmed. Among genes related to nerve development and differentiation, Ntrk and Neuregulin 1, which are necessary for neural differentiation and plasticity, were expressed at reduced levels in FGR fetuses. Under normal conditions, Neurogenin 1 and Neurogenin 2 are expressed mid-embryogenesis and are related to neural differentiation, but they are not expressed during late embryonic development. The expression of these two genes increased in FGR fetuses, suggesting that neural differentiation is delayed with FGR. Uterine and ovarian arteries were clipped and periodically opened to give a hypoxic load mimicking the time of labor, and the bleeding rate significantly increased in the FGR group. This suggests that FGR deteriorates cardiac autonomic control, which becomes a risk factor for cerebral hemorrhage onset at birth. This study demonstrated that cerebral hemorrhage risk may be evaluated before parturition for FGR management by evaluating the STV. Further, this study suggests that choosing an appropriate delivery timing and delivery method contributes to neurological prognosis improvement.
Collapse
|
16
|
Jezewski J, Wrobel J, Matonia A, Horoba K, Martinek R, Kupka T, Jezewski M. Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation? Front Physiol 2017; 8:305. [PMID: 28559852 PMCID: PMC5432618 DOI: 10.3389/fphys.2017.00305] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Accepted: 04/27/2017] [Indexed: 12/02/2022] Open
Abstract
Great expectations are connected with application of indirect fetal electrocardiography (FECG), especially for home telemonitoring of pregnancy. Evaluation of fetal heart rate (FHR) variability, when determined from FECG, uses the same criteria as for FHR signal acquired classically—through ultrasound Doppler method (US). Therefore, the equivalence of those two methods has to be confirmed, both in terms of recognizing classical FHR patterns: baseline, accelerations/decelerations (A/D), long-term variability (LTV), as well as evaluating the FHR variability with beat-to-beat accuracy—short-term variability (STV). The research material consisted of recordings collected from 60 patients in physiological and complicated pregnancy. The FHR signals of at least 30 min duration were acquired dually, using two systems for fetal and maternal monitoring, based on US and FECG methods. Recordings were retrospectively divided into normal (41) and abnormal (19) fetal outcome. The complex process of data synchronization and validation was performed. Obtained low level of the signal loss (4.5% for US and 1.8% for FECG method) enabled to perform both direct comparison of FHR signals, as well as indirect one—by using clinically relevant parameters. Direct comparison showed that there is no measurement bias between the acquisition methods, whereas the mean absolute difference, important for both visual and computer-aided signal analysis, was equal to 1.2 bpm. Such low differences do not affect the visual assessment of the FHR signal. However, in the indirect comparison the inconsistencies of several percent were noted. This mainly affects the acceleration (7.8%) and particularly deceleration (54%) patterns. In the signals acquired using the electrocardiography the obtained STV and LTV indices have shown significant overestimation by 10 and 50% respectively. It also turned out, that ability of clinical parameters to distinguish between normal and abnormal groups do not depend on the acquisition method. The obtained results prove that the abdominal FECG, considered as an alternative to the ultrasound approach, does not change the interpretation of the FHR signal, which was confirmed during both visual assessment and automated analysis.
Collapse
|
17
|
Li R, Frasch MG, Wu HT. Efficient Fetal-Maternal ECG Signal Separation from Two Channel Maternal Abdominal ECG via Diffusion-Based Channel Selection. Front Physiol 2017; 8:277. [PMID: 28559848 PMCID: PMC5432652 DOI: 10.3389/fphys.2017.00277] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2017] [Accepted: 04/18/2017] [Indexed: 12/19/2022] Open
Abstract
There is a need for affordable, widely deployable maternal-fetal ECG monitors to improve maternal and fetal health during pregnancy and delivery. Based on the diffusion-based channel selection, here we present the mathematical formalism and clinical validation of an algorithm capable of accurate separation of maternal and fetal ECG from a two channel signal acquired over maternal abdomen. The proposed algorithm is the first algorithm, to the best of the authors' knowledge, focusing on the fetal ECG analysis based on two channel maternal abdominal ECG signal, and we apply it to two publicly available databases, the PhysioNet non-invasive fECG database (adfecgdb) and the 2013 PhysioNet/Computing in Cardiology Challenge (CinC2013), to validate the algorithm. The state-of-the-art results are achieved when compared with other available algorithms. Particularly, the F1 score for the R peak detection achieves 99.3% for the adfecgdb and 87.93% for the CinC2013, and the mean absolute error for the estimated R peak locations is 4.53 ms for the adfecgdb and 6.21 ms for the CinC2013. The method has the potential to be applied to other fetal cardiogenic signals, including cardiac doppler signals.
Collapse
|
18
|
Surveillance of fetal arrhythmias in the outpatient setting: current limitations and call for action. Cardiol Young 2015; 25:1590-2. [PMID: 26675609 DOI: 10.1017/s1047951115002486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Surveillance of fetal arrhythmias in the outpatient setting remains limited by lack of monitoring modalities. Despite technological advances made in the field of obstetrics, existing devices are not currently suitable to monitor fetal arrhythmias. In this report, the author describes the current and developing fetal heart rate monitoring technologies including the recent introduction of hand-held Doppler monitors for outpatient surveillance of fetal arrhythmias.
Collapse
|
19
|
Narayan HK, Vignola EF, Fifer WP, Williams IA. Assessment of Cardiac Rate and Rhythm in Fetuses with Arrhythmia via Maternal Abdominal Fetal Electrocardiography. AJP Rep 2015; 5:e176-82. [PMID: 26495180 PMCID: PMC4603866 DOI: 10.1055/s-0035-1558401] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2015] [Accepted: 04/30/2015] [Indexed: 10/29/2022] Open
Abstract
Objective This study aims to report our experience using the Monica AN24 (Monica Healthcare Ltd., Nottingham, United Kingdom), a maternal transabdominal fetal electrocardiographic monitor, in a case series of fetuses with arrhythmias. Study Design We recorded fetal electrocardiograms (fECGs) on subjects with fetal arrhythmias diagnosed by fetal echocardiogram. Fetal heart rate and rhythm were determined via manual fECG analysis. Results Overall, 20 fECGs were recorded from a pool of 13 subjects. Fetal heart rate acquisition was determined to be high, medium, and poor quality in 10, 3, and 7 tracings, respectively. High-quality tracings were obtained in 9 of 11 subjects with gestational age < 26 or > 34 weeks. P waves were detectable in five tracings. Conclusion In subjects < 26 or > 34 weeks' gestational age, there was reasonable success in fetal heart rate acquisition. Further study is warranted to determine the potential role of this device in the monitoring of subjects with fetal arrhythmias.
Collapse
|
20
|
Becker JH, Krikhaar A, Schuit E, Mårtendal A, Maršál K, Kwee A, Visser GHA, Amer-Wåhlin I. The added predictive value of biphasic events in ST analysis of the fetal electrocardiogram for intrapartum fetal monitoring. Acta Obstet Gynecol Scand 2014; 94:175-82. [PMID: 25421390 DOI: 10.1111/aogs.12548] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Accepted: 11/20/2014] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To study the predictive value of biphasic ST-events for interventions for suspected fetal distress and adverse neonatal outcome, when using ST-analysis of the fetal electrocardiogram (FECG) for intrapartum fetal monitoring. DESIGN Prospective cohort study. SETTING Three academic hospitals in Sweden. POPULATION Women in labor with a high-risk singleton fetus in cephalic position beyond 36 weeks of gestation. METHODS In women in labor who were monitored with conventional cardiotocography, ST-waveform analysis was recorded and concealed. Traces with biphasic ST-events of the FECG (index) were compared with traces without biphasic events of the FECG. The ability of biphasic events to predict interventions for suspected fetal distress and adverse outcome was assessed using univariable and multivariable logistic regression analyses. MAIN OUTCOME MEASURES Interventions for suspected fetal distress and adverse outcome (defined as presence of metabolic acidosis (i.e. umbilical cord pH <7.05 and base deficit in extracellular fluid >12 mmol), umbilical cord pH <7.00, 5-min Apgar score <7, admittance to neonatal intensive care unit or perinatal death). RESULTS Although the presence of biphasic events of the FECG was associated with more interventions for fetal distress and an increased risk of adverse outcome compared with cases with no biphasic events, the presence of significant (i.e. intervention advised according to cardiotocography interpretation) biphasic events showed no independent association with interventions for fetal distress [odds ratio (OR) 1.71, 95% confidence interval (CI) 0.65-4.50] or adverse outcome (OR 1.96, 95% CI 0.74-5.24). CONCLUSION The presence of significant biphasic events did not discriminate in the prediction of interventions for fetal distress or adverse outcome. Therefore, biphasic events in relation to ST-analysis monitoring during birth should be omitted if future studies confirm our findings.
Collapse
|
21
|
Steer PJ, Hvidman LE. Scientific and clinical evidence for the use of fetal ECG ST segment analysis (STAN). Acta Obstet Gynecol Scand 2014; 93:533-8. [PMID: 24597897 DOI: 10.1111/aogs.12369] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Accepted: 02/27/2014] [Indexed: 11/29/2022]
Abstract
Fetal electrocardiogram waveform analysis has been studied for many decades, but it is only in the last 20 years that computerization has made real-time analysis practical for clinical use. Changes in the ST segment have been shown to correlate with fetal condition, in particular with acid-base status. Meta-analysis of randomized trials (five in total, four using the computerized system) has shown that use of computerized ST segment analysis (STAN) reduces the need for fetal blood sampling by about 40%. However, although there are trends to lower rates of low Apgar scores and acidosis, the differences are not statistically significant. There is no effect on cesarean section rates. Disadvantages include the need for amniotic membranes to be ruptured so that a fetal scalp electrode can be applied, and the need for STAN values to be interpreted in conjunction with detailed fetal heart rate pattern analysis.
Collapse
|
22
|
van Laar JOEH, Warmerdam GJJ, Verdurmen KMJ, Vullings R, Peters CHL, Houterman S, Wijn PFF, Andriessen P, van Pul C, Guid Oei S. Fetal heart rate variability during pregnancy, obtained from non-invasive electrocardiogram recordings. Acta Obstet Gynecol Scand 2013; 93:93-101. [PMID: 24134552 DOI: 10.1111/aogs.12286] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2013] [Accepted: 10/12/2013] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Non-invasive spectral analysis of fetal heart rate variability is a promising new field of fetal monitoring. To validate this method properly, we studied the relationship between gestational age and the influence of fetal rest-activity state on spectral estimates of fetal heart rate variability. DESIGN Prospective longitudinal study. SETTING Tertiary care teaching hospital. POPULATION Forty healthy women with an uneventful singleton pregnancy. METHODS Non-invasive fetal electrocardiogram measurements via the maternal abdomen were performed at regular intervals between 14 and 40 weeks of gestation and processed to detect beat-to-beat fetal heart rate. Simultaneous ultrasound recordings were performed to assess fetal rest-activity state. MAIN OUTCOME MEASURES Absolute and normalized power of fetal heart rate variability in the low (0.04-0.15 Hz) and high (0.4-1.5 Hz) frequency band were obtained, using Fourier Transform. RESULTS 14% of all measurements and 3% of the total amount of abdominal data (330 segments) was usable for spectral analysis. During 21-30 weeks of gestation, a significant increase in absolute low and high frequency power was observed. During the active state near term, absolute and normalized low frequency power were significantly higher and normalized high frequency power was significantly lower compared with the quiet state. CONCLUSIONS The observed increase in absolute spectral estimates in preterm fetuses was probably due to increased sympathetic and parasympathetic modulation and might be a sign of autonomic development. Further improvements in signal processing are needed before this new method of fetal monitoring can be introduced in clinical practice.
Collapse
|
23
|
Wei Z, Xueyun W, Jian jian Z, Hongxing L. Noninvasive fetal ECG estimation using adaptive comb filter. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2013; 112:125-134. [PMID: 23942332 DOI: 10.1016/j.cmpb.2013.07.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2012] [Revised: 06/06/2013] [Accepted: 07/21/2013] [Indexed: 06/02/2023]
Abstract
This paper describes a robust and simple algorithm for fetal electrocardiogram (FECG) estimation from abdominal signal using adaptive comb filter (ACF). The ACF can adjust itself to the temporal variations in fundamental frequency, which makes it qualified for the estimation of quasi-periodic component from physiologic signal, such as ECG. The validity and performance of the described method are confirmed through experiments on real fetal ECG data. A comparison with the well-known independent component analysis (ICA) method has also been presented.
Collapse
|
24
|
Narayan HK, Fifer W, Carroll S, Kern J, Silver E, Williams IA. Hypoplastic left heart syndrome with restrictive atrial septum and advanced heart block documented with a novel fetal electrocardiographic monitor. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2011; 38:472-474. [PMID: 21374749 PMCID: PMC3612972 DOI: 10.1002/uog.8982] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 02/21/2011] [Indexed: 05/30/2023]
Abstract
Hypoplastic left ventricle with congenital heart block has been reported previously in a fetus with concurrent left atrial isomerism and levo-transposition of the great arteries. We present the unusual case of an infant diagnosed in utero with hypoplastic left heart syndrome, a restrictive atrial septum and advanced heart block but with D-looping of the ventricles and no atrial isomerism. In addition, fetal heart rhythm was documented with the assistance of a new fetal electrocardiographic monitor.
Collapse
|