Effective Handwashing Practice in Dilla University Referral Hospital; Duration of Hand Rubbing and the Amount of Water as Key Enablers.
ENVIRONMENTAL HEALTH INSIGHTS 2022;
16:11786302221093481. [PMID:
35465143 PMCID:
PMC9021515 DOI:
10.1177/11786302221093481]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Accepted: 03/23/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND
Ineffective hand hygiene in healthcare settings is a global challenge that is associated with a high rate of nosocomial infections. The study aimed to measure the effectiveness of handwashing at Dilla University referral hospital.
METHOD
This study consisted of 2 parts; the survey work and laboratory analysis. A total of 63 participants were selected to take surveys using an interviewer-administered questionnaire to collect the data regarding the socio-demographic and hand hygiene-related practices. A laboratory tests (swab test) was used to assess handwashing effectiveness from 63 participants by taking 126 swab test (63 before and after hand washing sessions). A swab test was collected from the palms of each participant before and after hand washing using a sterile technique. The cultures were then incubated aerobically overnight at 37°C, and examined for microbial growth. The bacterial load was reported as the number of colony-forming units (CFU).
RESULT
The proportion of effective hand washing in Dilla University Referral Hospital was 82.5%. The mean colony-forming unit before and after handwashing were 55 and 2 CFU/ml, respectively with an average reduction of 94.6% in terms of CFU/ml. The mean amount of water used for effective handwashing was 336.03 (±219.46) ml. There was a significant mean difference in the amount of water used and duration of hand rubbing between effective and non-effective handwashing among the participants (P < 0.01). The bacterial load before and after handwashing indicated that there was a significant (53.3 mean CFU) reduction in bacterial load after handwashing practice which indicated that the handwashing intervention in the Referral hospital was effective (P < 0.01).
CONCLUSION
The proportion of effective Hand washing in Dilla University referral Hospital was 82.5% with a 94.6% reduction in terms of (CFU/ml). The amount of water use and the duration of hand rubbing showed a significant difference in the reduction of the microbial load.