Parastomal hernia repair according to Modified Stapled Mesh Stoma Reinforcement Technique (mSMART): which are the results ?
Hernia 2024:10.1007/s10029-024-03005-z. [PMID:
38607609 DOI:
10.1007/s10029-024-03005-z]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Accepted: 02/23/2024] [Indexed: 04/13/2024]
Abstract
INTRODUCTION
Parastomal hernia repair is a real surgical challenge because of the high rate of recurrence. The Stapled Mesh Stoma Reinforcement Technique (SMART) is a keyhole-like technique in which the mesh is stapled to the fascia using a circular mechanical stapler.
METHODS
A prospective study from January 2021 to February 2023 was conducted including all patients operated with the SMART technique. Primary endpoint was the recurrence rate during the follow-up. Secondary endpoints were reoperation, Surgical site Occurrence (SSO) and deep (mesh) surgical site infection (SSI) within 30 days postoperatively.
RESULTS
Sixteen patients operated on SMART procedures were included. The mean follow-up was 11.3 ± 9.2 months. The SSO rate was 18.7% (n = 3). A seroma was drained radiologically (IIIa), one haematoma was evacuated surgically (IIIb) and one patient presented a postoperative lesion of a ureter after a parastomal Bricker's hernia repair. In addition, there was one death due to multiple organ failure (V). There was no SSI. The recurrence rate was 57.1% during the follow-up.
CONCLUSION
This study shows disappointing results for this SMART technique, with a high recurrence rate.
Collapse