1
|
Numerical study of pedicle screw construction and locking compression plate fixation in posterior pelvic ring injuries: Analyzed by finite element method. Medicine (Baltimore) 2024; 103:e38258. [PMID: 38758846 PMCID: PMC11098222 DOI: 10.1097/md.0000000000038258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Accepted: 04/25/2024] [Indexed: 05/19/2024] Open
Abstract
BACKGROUND The aim of this study was to compare the biomechanical performance of pedicle screw construction and locking compression plate fixation in posterior pelvic ring injuries analyzed by finite element method. METHODS A 3-dimensional finite element model of the spine-pelvis-femur complex with ligaments was reconstructed from computed tomography images. An unstable posterior pelvic ring injury was created, which was fixed with a pedicle screw construction or locking compression plate. A follower load of 400 N was applied to the upper surface of the vertebrae to simulate the upper body weight, while the ends of the proximal femurs were fixed. The construct stiffness, the maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum, and stress distributions of the implants and pelvises were assessed. RESULTS The construct stiffness of the pedicle screw model (435.14 N/mm) was 2 times that of the plate model (217.01 N/mm). The maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the pedicle screw model were smaller than those in the plate model (0.919, 1.299, 0.259, and 1.413 mm in the pedicle screw model, and 1.843, 2.300, 1.053, and 2.895 mm in the plate model, respectively). The peak stresses of the implant and pelvis in the pedicle screw model decreased by 80.4% and 25% when compared with the plate model (44.57 and 34.48 MPa in the pedicle screw model, and 227.47 and 45.97 MPa in the plate model, respectively). CONCLUSION The study suggested that the pedicle screw construction could provide better fixation stability than the locking compression plate and serves as the recommended fixation method for the treatment of posterior pelvic ring injuries.
Collapse
|
2
|
[Effectiveness of vertical compression of locking plate combined with hollow screws in treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2024; 38:432-437. [PMID: 38632062 PMCID: PMC11024527 DOI: 10.7507/1002-1892.202312027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 03/18/2024] [Indexed: 04/19/2024]
Abstract
Objective To probe into the effectiveness of vertical compression of locking plate combined with hollow screws in the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures. Methods The clinical data of 128 patients with Sanders type Ⅱ and Ⅲ calcaneal fractures who were admitted between March 2019 and April 2022 and met the selection criteria were retrospectively analyzed. Among them, 65 patients were treated with locking plate combined with hollow screw vertical compression (study group), and 63 patients were treated with simple locking plate (control group). There was no significant difference in baseline data between the two groups ( P>0.05), such as gender, age, fracture side and Sanders classification, cause of injury, time from injury to operation. The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded and compared between the two groups. Before operation and at 12 months after operation, the American Orthopaedic Foot and Ankle Association (AOFAS) score (including total score, pain score, functional score, and alignment score) was used to evaluate the recovery of foot function, and imaging indicators such as calcaneal width, calcaneal height, calcaneal length, Böhler angle, and Gissane angle were measured on X-ray films. Results All patients were followed up 12 months after operation. There was no significant difference in operation time, intraoperative blood loss, hospital stay, and fracture healing time between the two groups ( P>0.05). Poor wound healing occurred in 1 case in the study group and 2 cases in the control group. At 12 months after operation, there was no significant difference between the two groups in the pre- and post-operative difference of calcaneal length, calcaneal height, Gissane angle, and Böhler angle ( P>0.05). However, the pre- and post-operative difference in calcaneal width in the study group was significantly higher than that in the control group ( P<0.05). The pre- and post-operative difference of AOFAS total score in the study group was significantly higher than that in the control group ( P<0.05), and further analysis showed that the pre- and post-operative difference of pain and function scores in the study group were significantly higher than those in the control group ( P<0.05), while there was no significant difference in the pre- and post-operative difference of force score between the two groups ( P>0.05). Conclusion Compared with simple locking plate treatment, the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures with vertical compression of locking plate combined with hollow screws can more effectively improve the width of the subtalar calcaneal articular surface, avoid peroneal longus and brevis impingement, reduce pain, and increase the range of motion of the subtalar joint, and the effectiveness is better.
Collapse
|
3
|
Comparison of Locking Plate Alone and Locking Plate Combined with 3D Printed Polymethylmethacrylate Augmentation in Treating Proximal Humerus Fractures in the Elderly. J Shoulder Elbow Surg 2024:S1058-2746(24)00186-1. [PMID: 38521483 DOI: 10.1016/j.jse.2024.01.046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 01/29/2024] [Accepted: 01/30/2024] [Indexed: 03/25/2024]
Abstract
BACKGROUND Locking plates are widely used in open reduction internal fixation (ORIF) for proximal humeral fracture (PHF). However, the optimal surgical treatment of unstable, displaced PHF in elderly patients remains controversial. This study aimed to compare the radiological and clinical outcomes of surgical treatment of PHF in the elderly with locking plate (LP) alone and locking plate combined with 3D printed polymethylmethacrylate (PMMA) prosthesis augmentation (LP-PA). METHODS From May 2015 to April 2021, a total of 97 patients aged ≥ 60 years with acute unstable PHF who underwent osteosynthesis with either LP (46 patients) or LP-PA (51 patients) were retrospectively analyzed. For the LP-PA group, a customized proximal humeral prosthesis made of PMMA cement was intra-operatively fabricated by a three-dimensional (3D) printed prototype mold for the humeral medial support. Radiological outcomes were analyzed by measuring the value of neck-shaft angle (NSA) and humeral head height (HHH). The clinical outcomes were evaluated using Constant-Murley Score (CMS), Disabilities of the Arm Shoulder and Hand (DASH) score, American Shoulder and Elbow Surgeons (ASES) score, and the shoulder range of motion (ROM). Pain was measured using a visual analogue scale (VAS). RESULTS At the one-year follow-up, all fractures healed radiologically and clinically. The mean changes of NSA and HHH over the follow-up period were markedly smaller in the LP-PA group (3.8 ± 0.9° and 1.7 ± 0.3 mm) than those in the LP group (9.7 ± 2.1° and 3.2 ± 0.6 mm, both P < 0.0001). The LP-PA group also presented lower DASH score (17.1 ± 3.6), higher ASES score (89.5 ± 11.2) and better ROM in forward elevation (142 ± 26°) and external rotation (59 ± 11°) compared to the LP group (28.9 ± 4.8 for DASH score, P < 0.0001; 82.3 ± 9.0 for ASES score, P < 0.001; 129 ± 21° for forward elevation, P = 0.008; and 52 ± 9° for external rotation, P = 0.001). There was no significant difference in overall complication rate between the two groups, although the complication rate of screw perforation was higher in the LP-PA group (P = 0.172). CONCLUSIONS For PHF in elderly patients, the combination of LP fixation and PMMA prosthesis augmentation effectively improved humeral head support and reduction maintenance, providing satisfactory outcomes both radiologically and clinically. This technique also reduced the incidence of screw perforation associated with plate fixation alone, making it a reasonable option to ensure satisfactory clinical outcomes.
Collapse
|
4
|
Infographic: Chongqing technique. Bone Joint Res 2024; 13:124-126. [PMID: 38461860 PMCID: PMC10924692 DOI: 10.1302/2046-3758.133.bjr-2023-0358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/12/2024] Open
Abstract
Cite this article: Bone Joint Res 2024;13(3):124–126.
Collapse
|
5
|
Severity of Complications after Locking Plate Osteosynthesis in Distal Femur Fractures. J Clin Med 2024; 13:1492. [PMID: 38592416 PMCID: PMC10934512 DOI: 10.3390/jcm13051492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 02/29/2024] [Accepted: 03/01/2024] [Indexed: 04/10/2024] Open
Abstract
Background: Locked plating for distal femur fractures is widely recommended and used. We systematically reviewed clinical studies assessing the benefits and harms of fracture fixation with locked plates in AO/OTA Type 32 and 33 femur fractures. Methods: A comprehensive literature search of PubMed, Embase, Cinahl, Web of Science, and the Cochrane Database was performed. The studies included randomized and non-randomized clinical trials, observational studies, and case series involving patients with distal femur fractures. Studies of other fracture patterns, studies conducted on children, pathological fractures, cadaveric studies, animal models, and those with non-clinical study designs were excluded. Results: 53 studies with 1788 patients were found to satisfy the inclusion and exclusion criteria. The most common harms were nonunion (14.8%), malunion (13%), fixation failure (5.3%), infection (3.7%), and symptomatic implant (3.1%). Time to full weight-bearing ranged from 5 to 24 weeks, averaging 12.3 weeks. The average duration of follow-up was 18.18 months, ranging from 0.5 to 108 months. Surgical time ranged between 40 and 540 min, with an average of 141 min. The length of stay in days was 12.7, ranging from 1 to 61. The average plate length was ten holes, ranging from 5 to 20 holes. Conclusion: This review aimed to systematically synthesize the available evidence on the risk associated with locked plating osteosynthesis in distal femur fractures. Nonunion is the most common harm and is the primary cause of reoperation. The overall combined risk of a major and critical complication (i.e., requiring reoperation) is approximately 20%.
Collapse
|
6
|
Locking plate versus K-wires and cast fixation in lateral closing-wedge osteotomy for cubitus varus deformity. Front Pediatr 2024; 12:1344283. [PMID: 38405594 PMCID: PMC10884614 DOI: 10.3389/fped.2024.1344283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2023] [Accepted: 01/19/2024] [Indexed: 02/27/2024] Open
Abstract
Background The aim of this study was to assess the clinical and radiographic outcomes of cubitus varus treatments based on different fixation methods: Locking plate vs. Kirschner-wires (K-wires) and cast fixation. Methods This retrospective study of 28 patients was performed in lateral-wedge osteotomy for cubitus varus deformity in our hospital from July 2018 to July 2020. 14 patients in group A were treated by locking plate after lateral closing-wedge osteotomy, whereas other 14 patients were treated by K-wires in group B. We measured the bony union and carrying angle. The clinical and radiographic outcomes were assessed according to the Bellemore criteria. Results No nonunion, neurovascular injury or myositis ossificans was noted at follow-up. In group A, 1 patient with lateral condylar prominence was found. In group B, 2 patients with pinning site infection were treated successfully with oral antibiotics and 2 patients needed revision surgery for residual varus. According to the Bellemore criteria, statistically significant difference was noted between the two groups (P = 0.0458). In the present study, no statistically significant difference was noted in the length of incision and operation time between the 2 groups (P > 0.05). However, the postoperative carrying angle was significantly different at final follow-up between the 2 groups (P < 0.01). Conclusions Compared with K-wires and cast fixation, we recommend the wedge osteotomy with lateral locking plate to treat the cubitus varus deformity because locking plate could achieve better functional and cosmetic results and stabilize the distal humerus rigidly.
Collapse
|
7
|
Comparing Intramedullary Nails and Locking Plates in Displaced Proximal Humerus Fracture Management: A Systematic Review and Meta-Analysis. Cureus 2024; 16:e54235. [PMID: 38496197 PMCID: PMC10944142 DOI: 10.7759/cureus.54235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/15/2024] [Indexed: 03/19/2024] Open
Abstract
This study aims to provide an updated review comparing the complication rates and clinical outcomes of intramedullary nails and locking plates (LPs) in displaced proximal humerus fracture (PHF) management. We performed a systematic review of the Cochrane Central Register of Controlled Trials, Clinical Trials Registry, EMBASE, and PubMed. Studies with level III evidence or higher comparing intramedullary nails and LPs used for internal fixation of displaced PHFs were included. The Methodological Index for Nonrandomized Studies (MINORS) criteria and Cochrane Handbook for Systematic Reviews of Interventions 5.2.0 were used to assess the risk of bias. Our meta-analysis included a comparison of method-related complications, pain scores, range of motion (ROM), and functional scores. A total of 13 comparative studies were included: five randomized controlled trials, three prospective cohort studies, and five retrospective cohort studies. The total number of patients included was 1,253 (677 in the LP group and 576 in the intramedullary nail group). Superior Constant-Murley scores and external rotation ROM were found in the LP group during the early postoperative period. However, long-term functional scores and complication rates were comparable between the two groups. We conclude that intramedullary nailing and LP fixation are both equally effective for the treatment of displaced PHFs. Neither treatment appears superior at this time, and more large-scale randomized controlled trials should be conducted to further evaluate the potential benefit of LPs in the early postoperative period.
Collapse
|
8
|
Outcome of Osteosynthesis of Late-Presenting Proximal Humerus Non-union: A Case Series. J Orthop Case Rep 2024; 14:165-172. [PMID: 38420251 PMCID: PMC10898685 DOI: 10.13107/jocr.2024.v14.i02.4258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 12/03/2023] [Indexed: 03/02/2024] Open
Abstract
Introduction It can be challenging to treat proximal humeral non-union (PHN). The challenge gets compounded when they are presented either late or after previous surgery. The challenges are far greater due to small proximal fragments, scalloping of the head, medial bone defect, osteoporosis, soft tissue contractures, and problems related to the previous implants. Material and Methods In this retro-prospective study (2007-2020), we report on six cases of PHN which were presented to us more than 5 years after the original injury and managed using an intra-medullary autologous fibular strut graft (FSG) along with fixation with a proximal humeral locking plate and cancellous bone grafting. We quantified shoulder function based on constant score and disabilities of the arm, shoulder and hand (DASH) score. Results The mean age of patients is found to be 54.3 years (range, 22-74 years) with females dominating our study. The mean pre-operative constant score is 26.33 which improved to 71.83 in the post-operative period. The mean DASH score is 77.98 preoperatively, which improved to 19.5 postoperatively. The paired sample t-test compared the difference in mean of the pre-operative and post-operative scores, which shows significant improvement in outcome. Conclusion Even in very late PHN in poor-quality bone, the additional use of intramedullary strut grafts provides structural support to the fixation and further enhances the ability to withstand the load-start early motion and have a satisfactory functional outcome. Keywords: Non-union, proximal humerus non-union, proximal humerus fracture, proximal humerus internal locking system, locking plate, autogenous fibular strut graft.
Collapse
|
9
|
Serum caspase‑1 levels serve as a predictive biomarker for the prognosis of patients undergoing arthroscopic‑assisted locking plate internal fixation in the treatment of high‑energy pilon fractures. Exp Ther Med 2024; 27:77. [PMID: 38264430 PMCID: PMC10804377 DOI: 10.3892/etm.2023.12365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 11/24/2023] [Indexed: 01/25/2024] Open
Abstract
The present study aimed to investigate the serum levels of caspase-1 in patients with high-energy pilon fractures, and its correlation with prognosis and clinical results. In this prospective study, 136 patients with high-energy pilon fractures who were treated with a locking plate combined with ankle arthroscopy from July 2015 to July 2020 were included. The treatment efficacy was evaluated according to the Mazur ankle function score. Serum caspase-1, interleukin (IL)-6, IL-1β and C-reactive protein (CRP) levels were measured using enzyme-linked immunosorbent assay. Reverse transcription-quantitative PCR was used to measure the mRNA expression of caspase-1. Additionally, demographic data and clinical characteristics, such as sex, age, intraoperative blood loss, fracture healing time, fracture classification and complications were collected and analyzed. The study revealed that the intraoperative blood loss, proportion of Ruedi-Allgower III and the serum levels of caspase-1 in the poor prognosis group were significantly higher compared with those in the good prognosis group. Additionally, patients with high-energy pilon fractures in the poor prognosis group exhibited significantly higher levels of caspase-1 and IL-1β serum levels at all time points in contrast to those in the good prognosis group. Spearman's analysis revealed a significant association between caspase-1, IL-1β levels and Mazur scores. Furthermore, caspase-1 could serve as a potential diagnostic biomarker for poor prognosis of patients with high-energy pilon fractures. Caspase-1, IL-1β, intraoperative blood loss and Ruedi-Allgower grade were the risk factors for poor prognosis in patients with high-energy pilon fractures. In summary, this study demonstrated that serum caspase-1 levels were progressively reduced during the treatment of high-energy pilon fractures patients and prominently lowered in those with a favorable prognosis. These findings could provide novel targets and a comprehensive approach to protecting patients with high-energy pilon fractures.
Collapse
|
10
|
A Novel Plating System for First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Hybrid and Traditional Locking Plate Constructs. Foot Ankle Spec 2023; 16:537-546. [PMID: 35048726 DOI: 10.1177/19386400211067860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
BACKGROUND Dorsal plate fixation is commonly used for first metatarsophalangeal joint (1st MTPJ) arthrodesis and plate design continues to evolve. A new staple compression plate (SCP) design attempts to utilize the continuous compression of a nitinol staple across the fusion site while simultaneously providing the stability of a dorsal locked plate. Herein, we compare the radiographic, clinical, and patient-reported outcomes of 1st MTPJ joint arthrodesis using 2 dorsal locking plate constructs including a novel SCP construct. METHODS Forty-four patients who underwent 1st MTPJ arthrodesis between 2016 and 2020 were retrospectively evaluated. There were 2 group cohorts. Group 1 cohort included 23 patients who received a CrossRoads Extremity SCP, and Group 2 cohort included 21 patients who received a Stryker dorsal locking precontoured titanium plate (LPP). All patients were evaluated with radiographs, Patient-Reported Outcomes Measures Information System (PROMIS) outcome scores, and Foot Function Index (FFI). RESULTS The complication and union rates did not vary between groups with a fusion rate of 95.7% in the SCP group and 90.5 % in the LPP group. Similarly, we found no significant differences in PROMIS or FFI scores between the SCP and LPP plates. CONCLUSION Use of either dorsal locking plate construct for 1st MTPJ arthrodesis was associated with high union rates and comparable functional outcomes. As locked plate technology continues to evolve for 1st MTPJ arthrodesis, it is important that clinical outcomes are reported. LEVELS OF EVIDENCE Level IV.
Collapse
|
11
|
Use of a preoperative 3D templating and proximal lateral tibial fitting patient-specific instrumentation in fixed valgus complex primary total knee arthroplasty for a patient with retaining hardware for internal fixation to treat Schatzker type V tibial plateau fracture: A case report. SAGE Open Med Case Rep 2023; 11:2050313X231215217. [PMID: 38033917 PMCID: PMC10687914 DOI: 10.1177/2050313x231215217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 10/25/2023] [Indexed: 12/02/2023] Open
Abstract
A 72-year-old female patient with a fixed valgus knee deformity due to a Schatzker type V tibial plateau fracture treated with bilateral locking plates 8 years ago was admitted to our clinic with complaints of chronic pain and knee instability when walking. Radiographs revealed Kellgren-Lawrence Classification grade 4 knee osteoarthritis and 20.5° of valgus knee deformity. She was treated with three-dimensional templating and proximal lateral tibial fitting patient-specific instrumentation-assisted mechanically aligned posterior sacrificing total knee arthroplasty with minimal removal of the retained hardware for the internal fixation of the tibial plateau fracture via a lateral approach, resulting in a favorable clinical outcome. The use of proximal lateral tibial fitting patient-specific instrumentation in fixed valgus complex primary total knee arthroplasty for patients with retaining hardware for internal fixation to treat tibial plateau fractures is considered a treatment option to decrease surgical invasion.
Collapse
|
12
|
Low Young's Modulus TiNbSn Alloy Locking Plates Accelerate Osteosynthesis in Rabbit Tibiae. TOHOKU J EXP MED 2023; 261:199-209. [PMID: 37704419 DOI: 10.1620/tjem.2023.j075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/15/2023]
Abstract
A new beta TiNbSn alloy with a low Young's modulus of approximately 40 GPa has been developed to resolve the stress shielding by Young's modulus divergence. In this study, the efficacy of TiNbSn alloy locking plates on bone repair is compared to that of commercially pure titanium (CP-Ti). The TiNbSn alloy and CP-Ti, which have Young's moduli of 49.1 GPa and 107 GPa, respectively, were compared. Male Japanese white rabbits were anesthetized, and osteotomy and osteosynthesis with locking plates were performed on the right tibia. The bone repair was assessed using micro-computed tomography (CT), histomorphometry, immunohistochemistry, and mechanical testing. Micro-CT, histomorphometry, immunohistochemistry, and mechanical testing were performed four weeks after osteotomy. Six weeks after surgery, micro-CT and mechanical testing were performed. Micro-CT analysis at four weeks after surgery showed that the intramedullary fracture callus in the TiNbSn alloy group had more bone volume and numerous bridging structures compared to the CP-Ti group (CP-Ti vs. TiNbSn alloy, 34.3 ± 13.1 mm3 vs. 61.3 ± 19.6 mm3, p = 0.02; mean ± standard deviation). At four weeks post-osteotomy, the healed tibia showed significantly higher strength in the TiNbSn alloy group compared with CP-Ti (CP-Ti vs. TiNbSn alloy, 81.3 ± 31.2 N vs. 133.7 ± 46.6 N, p = 0.04). TiNbSn alloy locking plates had a more positive impact on bone formation and bone strength restoration than the CP-Ti locking plates during the early phase of bone healing.
Collapse
|
13
|
[There is no difference in clinical outcomes in patients with distal Neer II and Neer V clavicle fractures treated with or without coracoclavicular augmentation systems]. ACTA ORTOPEDICA MEXICANA 2023; 37:344-349. [PMID: 38467455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/13/2024]
Abstract
INTRODUCTION the use of coracoclavicular augmentation systems together with locking plates in the treatment of unstable distal clavicle fractures (Neer II and Neer V) is controversial. MATERIAL AND METHODS patients with unstable distal clavicle fractures treated between 2013-2022 were retrospectively reviewed. The patients were divided into two groups: patients treated with locking plates (P group) and patients treated with locking plates and coracoclavicular augmentation systems (PCC group). Postoperative complications, modified preoperative and final coracoclavicular distance (CC), and outcomes on the Visual Analog Scale (VAS) and Quick Disabilities of the Arm, Shoulder, and Hand (Quick DASH) were recorded. RESULTS 16 of 23 patients were treated with plates only, and 7 of 23 were treated with plates and coracoclavicular augmentation systems. One case showed no fracture consolidation, and there was one case of cutaneous infection. The mean final CC distance was 23.7 in the P group and 22.1 in the PCC group. The mean VAS score was 1.3 in both the P and PCC groups, while the mean Quick DASH score was 5.5 in the P group and 8.1 in the PCC group. No significant differences were found in CC distance, VAS or Quick DASH scores. CONCLUSION the use of locking plates is likely sufficient in the management of unstable distal clavicle fractures, as there were no significant differences in functional outcomes in this study when coracoclavicular augmentation systems were used together with locking plates.
Collapse
|
14
|
Lower-limb internal loading and potential consequences for fracture healing. Front Bioeng Biotechnol 2023; 11:1284091. [PMID: 37901836 PMCID: PMC10602681 DOI: 10.3389/fbioe.2023.1284091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Accepted: 10/02/2023] [Indexed: 10/31/2023] Open
Abstract
Introduction: Mechanical loading is known to determine the course of bone fracture healing. We hypothesise that lower limb long bone loading differs with knee flexion angle during walking and frontal knee alignment, which affects fracture healing success. Materials and methods: Using our musculoskeletal in silico modelling constrained against in vivo data from patients with instrumented knee implants allowed us to assess internal loads in femur and tibia. These internal forces were associated with the clinical outcome of fracture healing in a relevant cohort of 178 extra-articular femur and tibia fractures in patients using a retrospective approach. Results: Mean peak forces differed with femoral compression (1,330-1,936 N at mid-shaft) amounting to about half of tibial compression (2,299-5,224 N). Mean peak bending moments in the frontal plane were greater in the femur (71-130 Nm) than in the tibia (from 26 to 43 Nm), each increasing proximally. Bending in the sagittal plane showed smaller mean peak bending moments in the femur (-38 to 43 Nm) reaching substantially higher values in the tibia (-63 to -175 Nm) with a peak proximally. Peak torsional moments had opposite directions for the femur (-13 to -40 Nm) versus tibia (15-48 Nm) with an increase towards the proximal end in both. Femoral fractures showed significantly lower scores in the modified Radiological Union Scale for Tibia (mRUST) at last follow-up (p < 0.001) compared to tibial fractures. Specifically, compression (r = 0.304), sagittal bending (r = 0.259), and frontal bending (r = -0.318) showed strong associations (p < 0.001) to mRUST at last follow-up. This was not the case for age, body weight, or localisation alone. Discussion: This study showed that moments in femur and tibia tend to decrease towards their distal ends. Tibial load components were influenced by knee flexion angle, especially at push-off, while static frontal alignment played a smaller role. Our results indicate that femur and tibia are loaded differently and thus require adapted fracture fixation considering load components rather than just overall load level.
Collapse
|
15
|
Risk Factors of Proximal Screw Breakage of Locking Plate (ZPLP ®) after MIPO for Distal Femur Fractures -Analysis of Patients with Plate Removal after Bony Union. J Clin Med 2023; 12:6345. [PMID: 37834989 PMCID: PMC10573958 DOI: 10.3390/jcm12196345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 09/23/2023] [Accepted: 09/26/2023] [Indexed: 10/15/2023] Open
Abstract
BACKGROUND Locking a compression plate is a more favorable surgical technique than intramedullary nailing in the treatment of distal femur fractures. This study analyzed the risk factors of proximal screw breakage retrospectively, which was confirmed in the patients with plate removal after bony union. METHODS A total of 140 patients who were fixed by MIPO using ZPLP from 2009 to 2019 were identified. A total of 42 patients met the inclusion criteria and were included. The screw breakage group (12 patients) and the non-breakage group (30 patients) were compared. RESULTS Approximately 12 (28.6%) of 42 plate-removal patients showed proximal screw breakage. The breakage of proximal screws developed at the junction of the screw head and neck. The number of broken proximal screws averaged 1.4 (1~4). The breakage of the proximal screw even after the bony union is more frequent in older patients (p = 0.023), the dominant side (p = 0.025), the use of the cortical screw as the proximal uppermost screw (p = 0.039), and the higher plate-screw density (p = 0.048). CONCLUSIONS Advanced age, dominant side, use of the cortical screw as the uppermost screw, and higher plate-screw density were related to proximal screw breakage. When the plate is removed after bony union or delayed union is shown in these situations, the possibility of proximal screw breakage should be kept in mind.
Collapse
|
16
|
Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study. J Hand Surg Eur Vol 2023; 48:872-876. [PMID: 37226467 DOI: 10.1177/17531934231176656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the trapeziometacarpal joint in ten pairs of fresh-frozen cadaveric hands. The biomechanical performance of each group was measured for stiffness in extension and flexion and load to failure using cantilever bending tests. The stiffness in extension was lower in the dorsally positioned group than in the radially positioned group (12.1 versus 15.2 N/mm, respectively). Load to failure was comparable between both groups (53.9 versus 50.9 N, respectively). A radially positioned locking plate for trapeziometacarpal arthrodesis may be biomechanically advantageous.
Collapse
|
17
|
First Tarsometatarsal Joint Fusion in Foot-A Biomechanical Human Anatomical Specimen Analysis with Use of Low-Profile Nitinol Staples Acting as Continuous Compression Implants. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1310. [PMID: 37512121 PMCID: PMC10383077 DOI: 10.3390/medicina59071310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 07/04/2023] [Accepted: 07/13/2023] [Indexed: 07/30/2023]
Abstract
Background and Objectives: The aim of this study was to investigate under dynamic loading the potential biomechanical benefit of simulated first tarsometatarsal (TMT-1) fusion with low-profile superelastic nitinol staples used as continuous compression implants (CCIs) in two different configurations in comparison to crossed screws and locked plating in a human anatomical model. Materials and Methods: Thirty-two paired human anatomical lower legs were randomized to four groups for TMT-1 treatment via: (1) crossed-screws fixation with two 4.0 mm fully threaded lag screws; (2) plate-and-screw fixation with a 4.0 mm standard fully threaded cortex screw, inserted axially in lag fashion, and a 6-hole TMT-1 Variable-Angle (VA) Fusion Plate 2.4/2.7; (3) CCI fixation with two two-leg staples placed orthogonally to each other; (4) CCI fixation with one two-leg staple and one four-leg staple placed orthogonally to each other. Each specimen was biomechanically tested simulating forefoot weightbearing on the toes and metatarsals. The testing was performed at 35-37 °C under progressively increasing cyclic axial loading until construct failure, accompanied by motion tracking capturing movements in the joints. Results: Combined adduction and dorsiflexion movement of the TMT-1 joint in unloaded foot condition was associated with no significant differences among all pairs of groups (p ≥ 0.128). In contrast, the amplitude of this movement between unloaded and loaded foot conditions within each cycle was significantly bigger for the two CCI fixation techniques compared to both crossed-screws and plate-and-screw techniques (p ≤ 0.041). No significant differences were detected between the two CCI fixation techniques, as well as between the crossed-screws and plate-and-screw techniques (p ≥ 0.493) for this parameter of interest. Furthermore, displacements at the dorsal and plantar aspects of the TMT-1 joint in unloaded foot condition, together with their amplitudes, did not differ significantly among all pairs of groups (p ≥ 0.224). Conclusions: The low-profile superelastic nitinol staples demonstrate comparable biomechanical performance to established crossed-screws and plate-and-screw techniques applied for fusion of the first tarsometatarsal joint.
Collapse
|
18
|
Comparison of intramedullary nail and plate osteosynthesis in humerus surgical neck fracture. ULUS TRAVMA ACIL CER 2023; 29:824-829. [PMID: 37409926 PMCID: PMC10405034 DOI: 10.14744/tjtes.2023.64225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 05/12/2023] [Indexed: 07/07/2023]
Abstract
BACKGROUND The aim of this study is to compare clinically and radiologically the plate osteosynthesis method and the in-tramedullary nail (IMN) method, which is currently used in the surgical treatment of surgical neck proximal humerus fractures (PHFs) in which there is no consensus METHODS: A total of 248 patients who underwent PHF between January 2013 and December 2017 were retrospectively reviewed. Sixty-two patients were included in the study. The results were clinically compared in terms of the amount of blood loss, operative time, and union time. Radiologically, it was compared in terms of intraoperative neck-shaft angle (NSA), final NSA, the American Shoulder and Elbow Surgeons (ASES), and Constant and Visual Analog Scale (VAS) scores. RESULTS Two groups were formed: plate and IMN. The groups were similar in terms of age, sex, operation side, and follow-up time. There was no difference between the groups in terms of NSA, final NSA, ASES, Constant, and VAS scores. The amount of intraoper-ative blood loss, operative time, and union time was shorter in the IMN group. CONCLUSION In surgical neck PHF surgery, plate and IMN are methods that show good clinical outcomes. According to this study, the advantages of the IMN method compared with plate osteosynthesis in Neer type II PHF treatment can be listed as less intraoper-ative blood loss, shorter operative time, and union time.
Collapse
|
19
|
Biomechanical Comparison of Medio-Plantar and Plantar Plate Fixation for First Tarsometatarsal Joint Arthrodesis. J Clin Med 2023; 12:3896. [PMID: 37373592 DOI: 10.3390/jcm12123896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 05/27/2023] [Accepted: 05/30/2023] [Indexed: 06/29/2023] Open
Abstract
Plantar plate positioning has been demonstrated as biomechanically superior. However, some operators remain resentful about the morbidity of the surgical approach. To provide improved plate fixation for first tarsometatarsal joint arthrodesis with respect to the tibialis anterior tendon, a medio-plantar plate was developed. The purpose of this biomechanical study was to compare its construct stability to that of a plantar plate construct. Twelve pairs of fresh frozen human specimens were used in a matched pair test. Each pair was fixed with a 4 mm compression screw and either a plantar locking plate or a medio-plantar locking plate. A cantilever beam test was performed in dorsiflexion. Before and after cyclic loading (5000 cycles; 40 N), bending stiffness and relative movements at the joint space were monitored in a quasi-static test including optical motion tracking. Maximum load and bending moment to failure were investigated in a load-to-failure ramp test. The bending stiffness of both groups did not significantly differ before (plantar 49.9 N/mm ± 19.2; medio-plantar 53.9 N/mm ± 25.4, p = 0.43) or after (plantar 24.4 N/mm ± 9.7; medio-plantar 35.3 N/mm ± 22.0, p = 0.08) cyclic loading but decreased significantly in both groups (p < 0.01) after cyclic loading. Relative movement increased significantly during cyclic testing in both groups (p < 0.01) but did not differ significantly between the groups before (p = 0.29) or after (p = 0.16) cyclic loading. Neither load nor bending moment to failure were significantly different (plantar 225 N ± 78, 10.8 Nm; medio-plantar 210 N ± 86, 10.1 Nm, p = 0.61). Both plate constructs provided equivalent construct stability, both being well suited for Lapidus arthrodesis.
Collapse
|
20
|
<Editors' Choice> Hook plate fixation versus locking plate fixation for distal clavicle fracture: a multicenter propensity score-matched study. NAGOYA JOURNAL OF MEDICAL SCIENCE 2023; 85:223-232. [PMID: 37346837 PMCID: PMC10281843 DOI: 10.18999/nagjms.85.2.223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 04/12/2022] [Indexed: 06/23/2023]
Abstract
Hook plate fixation and locking plate fixation are two standard internal fixation implants for treating distal clavicle fractures. We aimed to clarify the following: 1) Does the locking plate offer better clinical outcomes than the hook plate? 2) Is bone union better with a locking plate than hook plate? and 3) Are complications different between the locking plate and hook plate? We conducted a retrospective multicenter study of 338 patients who underwent surgery from 2014 to 2018 in our 10 hospitals, which comprise the TRON group. Of them, 208 patients treated using any plates were eligible. After 30 patients were excluded for various reasons, 178 patients were included. We classified them into two groups, locking plate group (Group L) and hook plate group (Group H), using propensity score matching. We confirmed bone union with an X-ray, evaluated the UCLA shoulder score, and compared the frequency of complications. After matching, Group L and Group H included 49 patients each. The UCLA score was higher in Group L than in Group H at each follow-up point. We confirmed bone union in all patients in Group L, but it was not confirmed in three patients (6.1%) in Group H. No statistically significant differences were observed except for plate migration, which was observed in nine patients (18.4%) in Group H but in no patients in Group L. The postoperative UCLA score was significantly better in Group L. We recommend the locking plate as a surgical treatment for distal clavicle fractures.
Collapse
|
21
|
Biomechanical analysis of plating techniques for unstable lateral clavicle fractures with coracoclavicular ligament disruption (Neer type IIB). J Shoulder Elbow Surg 2023; 32:695-702. [PMID: 36535559 DOI: 10.1016/j.jse.2022.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 11/01/2022] [Accepted: 11/10/2022] [Indexed: 12/23/2022]
Abstract
BACKGROUND Neer type IIB lateral clavicle fractures are inherently unstable fractures with associated disruption of the coracoclavicular (CC) ligaments. Because of the high rate of nonunion and malunion, surgical fixation is recommended; however, no consensus has been reached regarding the optimal fixation method. A new plating technique using a superior lateral locking plate with anteroposterior (AP) locking screws, resulting in orthogonal fixation in the lateral fragment, has been designed to enhance stability and reduce implant failure. The purpose of this study was to biomechanically compare 3 different clavicle plating constructs within a fresh frozen human cadaveric shoulder model. METHODS Twenty-four fresh frozen cadaveric shoulders were randomized into 3 groups (n = 8 specimens): group 1, lateral locking plate only (Medartis Aptus Superior Lateral Plate); group 2, lateral locking plate with CC stabilization (No. 2 FiberWire); and group 3, lateral locking plate with 2 AP locking screws stabilizing the lateral fragment. All specimens were subject to cyclic loading of 70 N for 500 cycles. Data were analyzed for gap formation after cyclic loading, construct stiffness, and ultimate load to failure, defined by a marked decrease in the load displacement curve. RESULTS After 500 cycles, there was no statistically significant difference between the 3 groups in gap formation (P = .179). No specimen (0/24) failed during cyclic loading. Ultimate load to failure was significantly higher in group 3 compared to group 1 (286 N vs. 167 N; P = .022), but not to group 2 (286 N vs. 246 N; P = .604). There were no statistically significant differences in stiffness (group 1: 504 N/mm; group 2: 564 N/mm; group 3: 512 N/mm; P = .712). Peri-implant fracture was the primary mode of failure for all 3 groups, with group 3 demonstrating the lowest rate of peri-implant fractures (group 1: 6/8; group 2: 7/8; group 3: 4/8; P = .243). CONCLUSION Biomechanical evaluation of the clavicle plating techniques showed effective fixation across all specimens at 500 cycles. The lateral locking plate with orthogonal AP locking screw fixation in the lateral fragment demonstrated the greatest ultimate failure load, followed by the lateral locking plate with CC stabilization. This new plating technique showed compatible stiffness and gap formation when compared to conventional lateral locking plates as well as plates with CC fixation. The use of orthogonal screw fixation in the distal fragment may negate against the need for CC stabilization in these types of fractures, thus minimizing surgical dissection around the coracoid and potential complications.
Collapse
|
22
|
Comparative study of three different fixation techniques for the treatment of Neer type IIb distal clavicle fractures: A retrospective cohort study. Front Surg 2023; 10:1100720. [PMID: 36814860 PMCID: PMC9939463 DOI: 10.3389/fsurg.2023.1100720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Accepted: 01/13/2023] [Indexed: 02/08/2023] Open
Abstract
Background Recently, a locking plate (LP) combined with a suture button was applied for distal clavicle Neer type IIb fractures. However, to our knowledge, there is limited information on clinical outcomes surrounding locking plates combined with a suture button in the treatment of Neer type IIb distal clavicle fractures. The aim of this study was to compare the outcomes among three different fixation techniques for the treatment of Neer type IIb distal clavicle fractures. Methods We performed a retrospective cohort study of 53 patients with Neer type IIb distal clavicle fractures who were treated with a hook plate (HP group, 16 patients), a locking plate alone (LP group, 18 patients), or a locking plate with a suture button (LPSB group, 19 patients) in our hospital between March 2014 and August 2019. The clinical and radiological outcomes were evaluated, including union time, postoperative complications, and function of the shoulder joint. Results The follow-up period was at least 2 years for all patients. All patients in the LPSB group achieved bone healing at the final follow-up. No significant differences were observed, including age, sex, side, time to surgery, duration of surgery, and mean follow-up period among the three groups (p > 0.05). The union time was shorter in the LPSB group than in the other two groups (p < 0.05). Postoperative complications were lower in the LPSB group than in the other two groups (p < 0.05). The visual analog scale score and Constant-Murley score in the LPSB group were better than those in the other groups at 3 and 6 months postoperatively (p < 0.05). Conclusion Compared with HP and LP alone, LPSB yields better clinical outcomes and lower complication rates in the treatment of Neer type IIb distal clavicle fractures.
Collapse
|
23
|
A Combination of Ilizarov Frame, Externalized Locking Plate and Tibia Bridging for an Adult with Large Tibial Defect and Severe Varus Deformity Due to Chronic Osteomyelitis in Childhood: A Case Report. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:medicina59020262. [PMID: 36837464 PMCID: PMC9958936 DOI: 10.3390/medicina59020262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 01/11/2023] [Accepted: 01/19/2023] [Indexed: 01/31/2023]
Abstract
Background: Various techniques have been reported to treat large, segmental tibial defects, such as autogenous bone graft, vascularized free fibula transfer and bone transport. We present a case of a 24-year-old male with a 17-year history of chronic osteomyelitis with obvious lower limb length discrepancy and severe varus deformity of the tibia secondary to osteomyelitis in childhood. Aim: The aim of this work is to provide an alternative choice for treating patients in developing countries with severe lower limb deformity caused by chronic osteomyelitis. Case Presentations: Without surgical intervention for a prolonged period of time, the patient was admitted in our institute for corrective surgery. Corrective surgery consisted of three stages: lengthening with Ilizarov frame, removal of Ilizarov frame and fixation with externalized locking plate, and removal of externalized locking plate. Tibia bridging was achieved at the distal and proximal junction. The range of motion (ROM) of the knee joint was nearly normal, but the stiffness of the ankle joint was noticeable. The remaining leg discrepancy of 0.1 cm required no application of a shoe lift. Moreover, the patient could engage in daily activities without noted limping. Conclusions: Distraction-compression osteogenesis using the Ilizarov apparatus is a powerful tool to lengthen the shortened long bone and adjust the deformity of the lower limbs. Externalized locking plates provide an alternative to the traditional bulky external fixator, as its low profile makes it more acceptable to patients without compromising axial and torsional stiffness. In all, a combination of Ilizarov frame, externalized locking plate and tibia bridging is an alternative for patients in similar conditions.
Collapse
|
24
|
Anterior locking plate versus non-operative treatment in different age groups with distal radial fractures: a systematic review and meta-analysis. J Hand Surg Eur Vol 2023; 48:532-543. [PMID: 36624925 DOI: 10.1177/17531934221143636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
This meta-analysis compared anterior locking plate and non-operative treatment for distal radial fractures and assessed if the age of the patients is associated with the treatment effect. We searched the MEDLINE, Embase and CENTRAL databases and included 12 studies with 1366 patients. Compared with non-operative care, anterior locking plate treatment does not seem to provide clinically important benefits in mean DASH score, mean pain or their mean quality of life at 12 to 24 months if the patients' ages are not considered (moderate to low certainty evidence). However, the younger the patients, the larger the benefit for surgery. Meta-regression with the DASH score suggested that while people over 70 likely experience no clinically relevant benefit from surgery, the mean effects cannot be generalized to people under 60. The evidence regarding the risk of adverse events is too uncertain to make firm conclusions.
Collapse
|
25
|
Titanium elastic nails vs locking plate in pediatric subtrochanteric femur fractures: A systematic review and meta-analysis. Front Pediatr 2023; 11:1114265. [PMID: 36937961 PMCID: PMC10020654 DOI: 10.3389/fped.2023.1114265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 01/30/2023] [Indexed: 03/06/2023] Open
Abstract
Objective Titanium elastic nails (TENs) and locking plates (LPs) are currently the main internal fixation for treating pediatric subtrochanteric femur fractures, and the optimal choice of internal fixation is controversial. This study aimed to systematically evaluate the effectiveness and safety of TENs and LPs in treating subtrochanteric fractures in children to provide a theoretical basis and reference for clinical treatment. Methods The literature related to TENs and LPs for treating subtrochanteric fractures in children was searched using the CNKI, PubMed, Cochrane, Embase, and Web of Science, and the search time frame was from the establishment of the database to October 2022. Two evaluators screened the literature according to the inclusion and exclusion criteria and extracted relevant data. Meta-analysis was performed using Stata14.0 software. Results A total of 9 studies with 407 patients with subtrochanteric femur fractures were included in the final screening, including 210 cases with TENs and 197 cases with LPs. Meta-analysis results showed that compared with the locking plate, TEN had a shorter operative time [WMD = -1.3, 95%CI(-1.94,-0.66), p < 0.01], less intraoperative bleeding [WMD = -84.45, 95%CI(-111.09, -57.82), p < 0.01], shorter fracture healing time [WMD = -1.3, 95%CI(-1.94,-0.66), P < 0.01], shorter hospital stays [WMD = -2.80, 95% CI(-4.63,-0.98), p < 0.01], and earlier full weight bearing [SMD = -0.48, 95% CI(-0.91,-0.04), p < 0.05] but more intraoperative fluoroscopy [WMD = 28.23, 95% CI(15.22,41.25), p < 0.05]. The overall complication rate was high [OR = 3.52, 95% CI(1.96,6.34), p < 0.05], and the postoperative period was prone to angulation, rotation, and inversion deformity [OR = 3.68, 95% CI(1.40, 9.68), p < 0.05]. No significant difference in the incidence of lower limb inequality between the two types of internal fixation [OR = 0.83, 95% CI(0.38, 1.85), p > 0.05] and no significant difference in the Harris score of the hip at the last follow-up between the two types of internal fixation [WMD = -0.67, 95% CI(-2.01,0.67), p > 0.05] were found. Conclusion In comparison to LPs, TENs have a shorter operation time, less intraoperative bleeding, and a shorter fracture healing time, and the child can be fully weight-bearing earlier. Locking plates can reduce the operator's x-ray exposure, and the incidence rate of postoperative angulation, rotation, and inversion deformity is low. Therefore, TENs and LPs are the best internal fixation methods for treating subtrochanteric fractures in children.
Collapse
|
26
|
Outcomes of the First Generation Locking Plate and Minimally Invasive Techniques Used for Fractures About the Knee. THE IOWA ORTHOPAEDIC JOURNAL 2023; 43:169-175. [PMID: 37383856 PMCID: PMC10296454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 06/30/2023]
Abstract
Background Locking plate technology was developed approximately 25-years-ago and has been successfully used since. Newer designs and material properties have been used to modify the original design, but these changes have yet to be correlated to improved patient outcomes. The purpose of this study was to evaluate the outcomes of first-generation locking plate (FGLP) and screw systems at our institution over an 18 year period. Methods Between 2001 to 2018, 76 patients with 82 proximal tibia and distal femur fractures (both acute fracture and nonunions) who were treated with a first-generation titanium, uniaxial locking plate with unicortical screws (FGLP), also known as a LISS plate (Synthes Paoli Pa), were identified and compared to 198 patients with 203 similar fracture patterns treated with 2nd and 3rd generation locking plates, or Later Generation Locking Plates (LGLP). Inclusion criteria was a minimum of 1-year follow-up. At latest follow-up, outcomes were assessed using radiographic analysis, Short Musculoskeletal Functional Assessment (SMFA), VAS pain scores, and knee ROM. All descriptive statistics were calculated using IBM SPSS (Armonk, NY). Results A total of 76 patients with 82 fractures had a mean 4-year follow-up available for analysis. There were 76 patients with 82 fractures fixed with a First-generation locking plate. The mean age at time of injury for all patients was 59.2 and 61.0% were female. Mean time to union for fractures about the knee fixed with FGLP was by 5.3 months for acute fractures and 6.1 months for nonunions. At final follow-up, the mean standardized SMFA for all patients was 19.9, mean knee range of motion was 1.6°-111.9°, and mean VAS pain score was 2.7. When compared to a group of similar patients with similar fractures and nonunions treated with LGLPs there were no differences in outcomes assessed. Conclusion Longer-term outcomes of first-generation locking plates (FGLP) demonstrate that this construct provides for a high rate of union and low incidence of complications, as well as good clinical and functional results. Level of Evidence: III.
Collapse
|
27
|
Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect. Front Bioeng Biotechnol 2023; 11:1099241. [PMID: 36937755 PMCID: PMC10020223 DOI: 10.3389/fbioe.2023.1099241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 02/23/2023] [Indexed: 03/06/2023] Open
Abstract
Purpose: Proximal tibial fractures are common, but the current available internal fixation strategies remain debatable, especially for comminuted fractures. This study aimed to compare the biomechanical stability of three internal fixation strategies for extra-articular comminuted proximal tibial fractures. Methods: A total of 90 synthetic tibiae models of simulated proximal tibial fractures with segmental bone defects were randomly divided into three groups: Single lateral plating (LP), double plating (DP) and intramedullary nailing (IN). Based on the different number of fixed screws, the above three groups were further divided into nine subgroups and subjected to axial compression, cyclic loading and static torsional testing. Results: The subgroup of intramedullary nailing with five proximal interlocking screws showed the highest axial stiffness of 384.36 ± 35.00 N/mm. The LP group obtained the lowest axial stiffness performance with a value of 96.59 ± 16.14 N/mm. As expected, the DP group offered significantly greater biomechanical stability than the LP group, with mean static axial stiffness and mean torque increasing by approximately 200% and 50%, respectively. According to static torsional experiments, the maximum torque of the DP subgroup was 3,308.32 ± 286.21 N mm, which outperformed all other groups in terms of torsional characteristics. Conclusion: Utilizing more than four distal screws did not provide improved biomechanical stability in the LP or DP groups, while a substantial increase in the biomechanical stability of DP was obtained when an additional medial plate was used. For the intramedullary nailing group, increasing the number of proximal interlocking screws could significantly improve biomechanical stability, and the intramedullary nailing with three proximal interlocking screws had similar static and cyclic stiffness as the DP group. The intramedullary nailing with five proximal screws had better axial stability, whereas DP had better torsional stability.
Collapse
|
28
|
Abstract
AIMS Distal third clavicle (DTC) fractures are increasing in incidence. Due to their instability and nonunion risk, they prove difficult to treat. Several different operative options for DTC fixation are reported but current evidence suggests variability in operative fixation. Given the lack of consensus, our objective was to determine the current epidemiological trends in DTC as well as their management within the UK. METHODS A multicentre retrospective cohort collaborative study was conducted. All patients over the age of 18 with an isolated DTC fracture in 2019 were included. Demographic variables were recorded: age; sex; side of injury; mechanism of injury; modified Neer classification grading; operative technique; fracture union; complications; and subsequent procedures. Baseline characteristics were described for demographic variables. Categorical variables were expressed as frequencies and percentages. RESULTS A total of 859 patients from 18 different NHS trusts (15 trauma units and three major trauma centres) were included. The mean age was 57 years (18 to 99). Overall, 56% of patients (n = 481) were male. The most common mechanisms of injury were simple fall (57%; n = 487) and high-energy fall (29%; n = 248); 87% (n = 748) were treated conservatively and 54% (n = 463) were Neer type I fractures. Overall, 32% of fractures (n = 275) were type II (22% type IIa (n = 192); 10% type IIb (n = 83)). With regards to operative management, 89% of patients (n = 748) who underwent an operation were under the age of 60. The main fixation methods were: hook plate (n = 47); locking plate (n = 34); tightrope (n = 5); and locking plate and tight rope (n = 7). CONCLUSION Our study is the largest epidemiological review of DTC fractures in the UK. It is also the first to review the practice of DTC fixation. Most fractures are being treated nonoperatively. However, younger patients, suffering a higher-energy mechanism of injury, are more likely to undergo surgery. Hook plates are the predominantly used fixation method followed by locking plate. The literature is sparse on the best method of fixation for optimal outcomes for these patients. To answer this, a pragmatic RCT to determine optimal fixation method is required.Cite this article: Bone Jt Open 2022;3(12):953-959.
Collapse
|
29
|
Bridged combined fixation system versus locking plate in the treatment of patients with implant periprosthetic refracture following proximal femoral fracture surgery: A retrospective observational study. Medicine (Baltimore) 2022; 101:e31538. [PMID: 36482553 PMCID: PMC9726297 DOI: 10.1097/md.0000000000031538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Locking plate (LP) re-fixation is mainly used to treat postoperative implant periprosthetic refractures; however, the extensive trauma and the fixation form of LP make the operation difficult. The bridge combined fixation system (BCFS) is a new clip-rod internal fixation system, and its clinical application is in its infancy. To compare the clinical effect of BCFS and LP in the treatment of geriatric postoperative implant periprosthetic refracture following proximal femoral fracture surgery. Thirty-two patients (14 with BCFS and 18 with LP) with postoperative implant periprosthetic refracture following proximal femoral fracture surgery, who underwent surgery in our hospital, were analyzed retrospectively. The incision length, operation time, intraoperative bleeding volume, postoperative drainage volume, postoperative hospital stay, fracture healing time and complications of each patient were recorded. Regular radiographs were taken after the operation to evaluate the fracture reduction and fixation. All the patients were followed for 12 months to evaluate their limb function by Johner-Wruhs scoring criteria. The patients were followed for an average of 24.1 months, and all achieved bony union, with no complications such as infection, nonunion, and internal fixation instrument falling off and loosening after the operation. Delayed healing occurred in two cases in the LP group. The average value of surgical incision length, operation time, postoperative hospitalization time and fracture healing time in the BCFS group were significantly smaller than those in the LP group, accompanied by a decrease in intraoperative bleeding and postoperative drainage volumes (P < .05). The rate of limb function in the BCFS group (85.7%) was higher than that in the LP group (83.3%), with no significance (P > .05). The BCFS in the refracture around the implant of the proximal femoral fracture exhibited many advantages such as simple operation, strong plasticity, effective reduction of surgical trauma, promotion of fracture healing and early functional rehabilitation, etc, making it an advantageous clinical application.
Collapse
|
30
|
Comparison of surgical efficacy of locking plates and interlocking intramedullary nails in the treatment of proximal humerus fractures. J Orthop Surg Res 2022; 17:481. [PMID: 36335350 PMCID: PMC9636665 DOI: 10.1186/s13018-022-03360-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 10/18/2022] [Indexed: 11/08/2022] Open
Abstract
Background The objective of this study was to evaluate the efficacy of locking plates versus interlocking intramedullary nails in the treatment of proximal humerus fractures to provide clinical data support and theoretical guidance. Methods Patients with proximal humerus fracture from the Third hospital of Shijiazhuang city and Third hospital of Hebei medical university and from January 2017 to June 2019 were selected, included and divided into the locking plate group and the interlocking intramedullary nail group according to the intervention received. Information pertaining to the perioperative period (operation time, hospital stay, blood loss, etc.) of patients in both groups was collected. VAS pain scores, shoulder activity Constant-Murley scores and postoperative complications were documented. The perioperative data of the two groups were compared, and P < 0.05 was considered statistically significant. Results A total of 64 patients were enrolled, including 36 patients in the locking plate group, with a mean age of 61.3 ± 13.9 years, while the mean age of the interlocking intramedullary nail group was 65.6 ± 11.2 years. There was no statistical difference in gender, affected side, injury mechanism and Neer classification between the two groups (P > 0.05). However, the average operation time of the locking plate group was shorter than that of the interlocking nail group (84.9 ± 11.7 vs. 102.6 ± 22.1 min, P = 0.00), and the intraoperative blood loss of the locking plate group (137.4 ± 16.8 ml) was higher than that of the interlocking nail group (72.5 ± 10.5 ml, P = 0.00). There was no significant difference in the VAS score and Constant-Murley score between these two groups at the final follow-up. Conclusion Interlocking intramedullary nails are more minimally invasive than locking plates, but fracture reduction and fixation take longer. There was no significant difference in pain and shoulder function scores between the two internal fixation strategies for the treatment of proximal humerus fracture.
Collapse
|
31
|
Surgical outcomes of non-periprosthetic distal femur fragility fractures treated with a locking plate. ANNALS OF JOINT 2022; 7:32. [PMID: 38529163 PMCID: PMC10929273 DOI: 10.21037/aoj-22-15] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 08/06/2022] [Indexed: 03/27/2024]
Abstract
Background Management of distal femur fractures can be challenging, particularly in the aged female population. This retrospective study aims to analyze the surgical outcomes of aged female patients with non-periprosthetic distal femur fractures treated with a locking plate. Methods This is an IRB approved retrospective review conducted at a level 1 trauma center. Fifty-five female patients (mean age of 71 years) with non-periprosthetic distal femur fractures underwent open reduction internal fixation using a locking plate from 2005 to 2019. The average follow-up time was 67 weeks from the date of injury. Criteria used for diagnosis of nonunion included one or more of the following: (I) three consecutive months without progression of healing on postoperative radiographs, (II) a total of nine months postoperative without complete healing, or (III) the physician diagnosed nonunion using clinical judgement. Outcome data was analyzed and compared amongst patients with and without obesity or diabetes. Statistical analysis was performed utilizing Microsoft Excel 2022 Data Analysis ToolPak with a standard statistically significant P value of <0.05. Results Thirty-two patients (58%) with distal femur fractures achieved union after initial treatment while 23 patients (42%) were diagnosed with nonunion. Fourteen patients (61%) underwent revision with 9 of these patients (64%) achieving union while 5 patients (36%) had persistent nonunion. Average healing time from initial treatment to union was 29 weeks, while average time from definitive treatment to union was 22 weeks. Obese patients [body mass index (BMI) >30 kg/m2] had a nonunion rate of 65%, while non-obese patients had a nonunion rate of 28%. Patients with diabetes had a nonunion rate of 65%, while patients without diabetes had a nonunion rate of 28%. Conclusions Union can be successfully achieved in aged female patients with distal femur fractures treated with locking plates; however, the risks for nonunion and revision remain high. Patients with obesity and diabetes appear to be at an increased risk of nonunion (P=0.008 and 0.008, respectively). However, further research should be conducted with a prospective study or multivariate analysis and increased number of patients to reaffirm this data.
Collapse
|
32
|
Corrective osteotomy for distal condylar malunion of the proximal phalanx in adolescents: comparison of K-wire and locking plate fixation. J Hand Surg Eur Vol 2022; 47:935-943. [PMID: 35579202 DOI: 10.1177/17531934221098006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
This retrospective study reviewed 28 patients, aged 10 to 17 years, who underwent corrective osteotomy for malunion of the proximal phalangeal distal condyles at a mean of 9 weeks (range 2-52) from injury. There were 19 patients treated with K-wire and nine patients with locking plates. The two groups were comparable for trauma mechanism, fracture type, time delay from injury and the type of initial treatment. The K-wire group had a shorter duration of operation and shorter time to union than the plating group. For both groups, postoperative radiographs showed significant correction, which remained unchanged until the final follow-up (minimum 12 months), although greater residual coronal angulation was found in the K-wire group. The outcomes in 17 of the 28 patients were graded as excellent or good according to the Al-Qattan classification, with no difference between the groups. The complication rate was also similar between the groups, while the locking plate group had a higher rate of secondary surgery.Level of evidence: III.
Collapse
|
33
|
Recovery of Forearm Bone Strength After Plate Removal: A Finite Element Analysis Study. J Hand Surg Am 2022:S0363-5023(22)00460-9. [PMID: 36123221 DOI: 10.1016/j.jhsa.2022.07.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 06/16/2022] [Accepted: 07/29/2022] [Indexed: 02/02/2023]
Abstract
PURPOSE The purpose of this study was to estimate the bone strength after plate removal over time and to investigate the progression of bone strength recovery. METHODS A consecutive series of 31 patients was investigated to evaluate bone strength before and after forearm plate removal. Patients who were included underwent plate fixation for forearm diaphyseal fractures and were scheduled for plate removal. Computed tomography (CT) scans of the entire length of the bilateral forearms were taken before plate removal and at 1, 3, and 6 months after surgery. Patient-specific CT-based finite element analysis was used to predict the forearm bone fracture strength against an axial load (N), defined as the bone strength. Bone strength was estimated by patient-specific CT-based finite element analysis at each time point. RESULTS The mean age of the patients was 40.4 years. The mean time between plate fixation and removal was 27.5 months. Bone strength before the removal was estimated as reduced to 47% of that of the uninjured side. This was constant regardless of age group, involvement of the radius or ulna, Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification, open fracture, or type of plate. Bone strength at 1, 3, and 6 months after removal was estimated to be 66%, 85%, and 97%, respectively. The bone strength of the distal ulna was weaker than that at the other sites in the forearm and showed delayed recovery. CONCLUSIONS Bone strength after plate removal showed recovery within 3-6 months and was fully recovered by 6 months. The degree of recovery of bone atrophy varies from site to site, and patients should be careful about refracture after removal. CLINICAL RELEVANCE Clinicians should be aware that bone strength may not be sufficiently restored even 6 months after plate removal of forearm fractures.
Collapse
|
34
|
Distal femur: nail plate combination and the linked construct. OTA Int 2022; 5:e172. [PMID: 37781482 PMCID: PMC10538551 DOI: 10.1097/oi9.0000000000000172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 12/06/2021] [Indexed: 10/03/2023]
Abstract
Operative fixation of distal femur fractures in patients with osteoporotic bone can be challenging. Treatment with either lateral locking plate or retrograde intramedullary nail alone may not provide adequate fixation to allow for early mobilization. Rather, fixation using the nail plate combination (NPC) to treat distal femur fractures in the elderly may offer improved biomechanical stability to achieve immediate weight-bearing, especially in the setting of complex fracture patterns and osteoporosis. Here, we describe the rationale, step-by-step technique, and outcome following 2 cases: 1 patient treated with a true NPC procedure using retrograde intramedullary nail and standard locking plate, as well as a NPC procedure using a novel locking attaching washer plate.
Collapse
|
35
|
[Effectiveness of tunnel osteogenesis technique in treatment of aseptic non-hypertrophic nonunion of femoral shaft]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2022; 36:976-982. [PMID: 35979789 PMCID: PMC9379460 DOI: 10.7507/1002-1892.202203083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
OBJECTIVE To investigate the effectiveness of tunnel osteogenesis technique combined with locking plate in the treatment of aseptic non-hypertrophic nonunion of femoral shaft. METHODS The clinical data of 23 cases of aseptic non-hypertrophic nonunion of femoral shaft treated with tunnel osteogenesis technique combined with locking plate between January 2017 and December 2020 were retrospectively analysed. There were 17 males and 6 females with an average age of 41.4 years (range, 22-72 years). There were 22 cases of closed fracture and 1 case of open fracture. The types of internal fixation at admission included intramedullary nail in 14 cases and steel plate in 9 cases. The number of nonunion operations received in the past was 0 to 1; the duration of nonunion was 6-60 months, with an average of 20.1 months. Among them, there were 17 cases of aseptic atrophic nonunion of the femoral shaft and 6 cases of dystrophic nonunion. Twenty-two cases were fixed with 90° double plates and 1 case with lateral single plate. The operation time, theoretical blood loss, hospitalization stay, nonunion healing, and postoperative complications were recorded. Harris hip function score, Lysholm knee function score, lower extremity function scale (LEFS), and short-form 36 health survey scale (SF-36) were used at last follow-up to evaluate hip and knee functions. Visual analogue scale (VAS) score was used to evaluate the relief of pain at 1 day after operation and at last follow-up. RESULTS The average operation time was 190.4 minutes, the average theoretical blood loss was 1 458.4 mL, and the average hospitalization stay was 8.2 days. All the 23 patients were followed up 9-26 months, with an average of 18.2 months. The healing time of nonunion in 22 patients was 3-12 months, with an average of 5.6 months. There were 8 cases of limb pain, 8 cases of claudication, 6 cases of limitation of knee joint movement, and 2 cases of limitation of hip joint movement. At last follow-up, the imaging of 1 patient showed that the nonunion did not heal, accompanied by pain of the affected limb, lameness, and limitation of knee joint movement. At 1 day after operation, the VAS score of 23 patients was 6.5±1.8, the pain degree was good in 7 cases, moderate in 12 cases, and poor in 4 cases; at last follow-up, the VAS score was 0.9±1.3, the pain degree was excellent in 21 cases and good in 2 cases, which were significantly better than those at 1 day after operation ( t=12.234, P<0.001; Z=-5.802, P<0.001). At last follow-up, the average Harris hip function score of 22 patients with nonunion healing was 94.8, and the good rate was 100%; Lysholm knee function score averaged 94.0, and the excellent and good rate was 90.9%; LEFS score averaged 74.6; SF-36 physical functioning score averaged 85.0 and the mental health score averaged 83.6. CONCLUSION Tunnel osteogenesis technique combined with locking plate in the treatment of aseptic non-hypertrophic nonunion of femoral shaft has a high healing rate and fewer complications, which can effectively relieve pain and improve lower limb function and quality of patients' life.
Collapse
|
36
|
Comparison of three different surgical treatment methods in humeral shaft fractures. Pan Afr Med J 2022; 42:88. [PMID: 36034025 PMCID: PMC9379442 DOI: 10.11604/pamj.2022.42.88.34692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 05/08/2022] [Indexed: 11/28/2022] Open
Abstract
INTRODUCTION in this study, we aimed to compare the clinical and radiological results of single 4.5 mm locking compression plate (LCP), dual 3.5 mm LCP and intramedullary nailing (IMN) methods applied to the surgical treatment of humeral shaft fractures. METHODS the study included 77 patients (41 males, 36 females; mean age 46.38 years; range 18-74 years) with humeral shaft fractures treated with a single 4.5 mm LCP, dual 3.5 mm LCP and IMN between January 2016 and December 2020. Single 4.5 mm LCP (Group A) was applied to 31 (40.3%) patients, dual 3.5 mm LCP (Group B) to 20 (26%) patients and IMN (Group C) to 26 (33.8%) patients. The preoperative and postoperative data of the patients were analyzed from the hospital registry system. A short version of the disabilities of the arm, shoulder and hand (QuickDASH) questionnaire was used to evaluate functional outcomes. RESULTS as a result of the comparison of the rates of nonunion between the groups, a significantly lower rate of nonunion was observed in group B patients (p=0.027). While the rate of nonunion was 14% in the cases included in the study, no cases of nonunion were encountered in group B. There was no difference between the three groups in terms of demographic data and other postoperative complications. CONCLUSION dual 3.5 mm LCP method is a suitable alternative to other surgical methods in the treatment of humeral shaft fractures, due to similar functional results and lesser nonunion.
Collapse
|
37
|
Outcome following management of unstable lateral end clavicle fractures with locking plate and coracoid anchor augmentation. Shoulder Elbow 2022; 14:181-188. [PMID: 35265184 PMCID: PMC8899329 DOI: 10.1177/1758573220981708] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Accepted: 11/25/2020] [Indexed: 11/17/2022]
Abstract
BACKGROUND Management of complex lateral end clavicle fractures with coraco-clavicular ligament disruption can be challenging. METHODS We prospectively analysed 19 (17 M:2F) patients from January 2014 to June 2016. Six patients had intra-articular fractures (Edinburgh-3B2) and the remaining were extra-articular (3B1). All patients had open reduction internal fixation with lateral end locking plate augmented with a coracoid anchor. All patients were evaluated at the final follow-up by American Shoulder and Elbow Surgeon score (ASES), Disabilities of the Arm, Shoulder and Hand (DASH), Oxford Shoulder Score (OSS), return to work, sports and radiographs. RESULTS At a mean follow-up of 54 months (range 37-64), 19 patients were available for analysis. Mean age of patients was 34 years (range 24-65). At final follow-up DASH score was 1.66 (range 0-5); ASES score was 98.14 (93.3-100) and OSS was 46.6 (42-48). There was no difference in the functional outcome between 3B1 and 3B2 fractures (DASH - p(0.51); ASES - p(0.44); OSS - p(0.69)). All patients returned to preinjury level of function, sports and work. Five patients needed implant removal and three developed capsulitis that resolved with conservative treatment. CONCLUSION Locking plate fixation, augmented with coracoid anchor is an effective option in the management of these complex injuries. The need for implant removal is reduced (26%) and there is no difference in the functional outcome between 3B1 and 3B2 fractures.
Collapse
|
38
|
Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures? MEDICINA (KAUNAS, LITHUANIA) 2022; 58:medicina58030382. [PMID: 35334558 PMCID: PMC8949819 DOI: 10.3390/medicina58030382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 02/03/2022] [Accepted: 03/02/2022] [Indexed: 11/30/2022]
Abstract
Background and Objectives: The aim of this study was to evaluate whether device removal in symptomatic patients following locking plate osteosynthesis of a proximal humerus fracture improves the clinical outcomes. Materials and Methods: Seventy-one patients who underwent fixed-angle locking plate osteosynthesis of a proximal humerus fracture were included. Thirty-three patients underwent device removal at a mean time of 10.4 months after index surgery (removal group). Thirty-eight patients who retained the device after index surgery (retention group) were included in the control group. Visual analog scale (VAS) pain score, University of California at Los Angeles (UCLA) score, American Shoulder and Elbow Surgeons (ASES) score, and range of motion (ROM) were evaluated pre- and postoperatively. Results: At the final follow-up, mean UCLA score, ASES score, and all ROMs were significantly higher in the removal group compared to the retention group (p < 0.001). However, no significant difference in mean VAS pain score was observed between the two groups. Comparison of the clinical outcomes before and after device removal surgery showed significant improvement in all clinical scores and ROMs after device removal (p < 0.001). Conclusions: Device removal surgery in symptomatic patients following locking plate osteosynthesis of a proximal humerus fracture can result in significant improvement in functional outcomes.
Collapse
|
39
|
[Comparison of locking plate and intramedullary nail in treatment of Neer two- and three-part fractures of the proximal humerus in the elderly]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2022; 36:274-278. [PMID: 35293166 PMCID: PMC8923928 DOI: 10.7507/1002-1892.202107003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
OBJECTIVE To compare the effectiveness of locking plate and intramedullary nail in treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. METHODS A retrospective analysis was conducted on 86 elderly patients with Neer two- and three-part fractures of the proximal humerus met the selection criteria between January 2015 and December 2018. Forty-six patients were treated with locking plate fixation (locking plate group), and 40 patients with intramedullary nail fixation (intramedullary nail group). There was no significant difference in gender, age, cause of injury, fracture side and type, time from injury to operation, and comorbidities between the two groups ( P>0.05). Visual analogue scale (VAS) score, American Shoulder and Elbow Surgery (ASES) score, Constant-Murley score, and shoulder range of motion (forward flexion, abduction, and external rotation) were compared between the two groups. X-ray films were taken to assess the fracture healing, and the neck-shaft angle was measured at 2 days after operation and at last follow-up, and the difference between the two time points was calculated. RESULTS Patients in both groups were followed up 18-40 months, with an average of 30.4 months. There was no significant difference in follow-up time between the two groups ( t=-0.986, P=0.327). X-ray films reexamination showed that the fractures of two groups healed, and the healing time was (11.3±2.1) weeks in locking plate group and (10.3±2.0) weeks in intramedullary nail group, which had significant difference between the two groups ( t=2.250, P=0.027). The difference of neck-shaft angle was (7.63±7.01)° in locking plate group and (2.85±2.82)° in intramedullary nail group, which had significant difference between the two groups ( t=4.032, P<0.001). There was no significant difference in Constant-Murley score, ASES score, VAS score, and shoulder range of motion between the two groups at last follow-up ( P>0.05). Complications occurred in 13 cases (28.3%) of locking plate group and in 4 cases (10.0%) of intramedullary nail group, and the difference between the two groups was significant ( χ 2=4.498, P=0.034). CONCLUSION Both locking plates and intramedullary nails can be used for the treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. The intramedullary nail fixation surgery is more minimally invasive, which has fewer postoperative complications and faster fracture healing.
Collapse
|
40
|
Operative Fixation of Lateral Malleolus Fractures With Locking Plates vs Nonlocking Plates: A Systematic Review and Meta-analysis. Foot Ankle Int 2022; 43:280-290. [PMID: 34581226 PMCID: PMC8841627 DOI: 10.1177/10711007211040508] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The exact benefit of locking plates over nonlocking plates in patients with lateral malleolus fractures remains unclear. The primary aim of this study was to compare the functional outcome of locking plates vs nonlocking plates in patients with a lateral malleolus fracture. The secondary aims were to compare the number of complications and hardware removals and to compare whether results differed for older patients and for patients treated with anatomical locking plates. METHODS The PubMed/MEDLINE, Embase, Cochrane, and CINAHL databases were searched for studies comparing locking plates with nonlocking plates in patients with fixated lateral malleolus fractures. All included studies were assessed on their methodologic quality using the MINORS. Subgroup analyses were performed on older patients and patients treated with anatomical locking plates. RESULTS A total of 11 studies were included. The meta-analysis showed that functional outcome did not differ between patients treated with locking plates and nonlocking plates (MD 2.38, 95% CI -2.71 to 7.46). No difference in both complication rate (OR 1.10, 95% CI 0.74-1.63) and the amount of hardware removals (OR 0.77, 95% CI 0.52-1.14) was found. Even after analyzing older patients and patients treated with anatomical locking plates, no benefit was shown. CONCLUSION This meta-analysis demonstrates no clear benefit in selecting locking plates over nonlocking plates in the treatment of lateral malleolus fractures. CLINICAL RELEVANCE Locking plates are increasingly being used in the treatment of lateral malleolus fractures. Biomechanical studies have shown an increased stability with use of locking vs nonlocking plates. This clinical review does not support a benefit of use of locking plates for these fractures.
Collapse
|
41
|
One size may not fit all: patient-specific computational optimization of locking plates for improved proximal humerus fracture fixation. J Shoulder Elbow Surg 2022; 31:192-200. [PMID: 34298147 DOI: 10.1016/j.jse.2021.06.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 06/04/2021] [Accepted: 06/12/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Optimal treatment options for proximal humerus fractures (PHFs) are still debated because of persisting high fixation failure rates experienced with locking plates. Optimization of the implants and development of patient-specific designs may help improve the primary fixation stability of PHFs and reduce the rate of mechanical failures. Optimizing the screw orientations in locking plates has shown promising results; however, the potential benefit of subject-specific designs has not been explored yet. The purpose of this study was to evaluate by means of finite element (FE) analyses whether subject-specific optimization of the screw orientations in a fixed-angle locking plate can reduce the predicted cutout failure risk in unstable 3-part fractures. METHODS FE models of 19 low-density proximal humeri were generated from high-resolution computed tomographic images using a previously developed and validated computational osteosynthesis framework. The specimens were virtually osteotomized to simulate unstable malreduced 3-part fractures and fixed with the PHILOS plates using 6 proximal locking screws. The average principal compressive strain in cylindrical bone regions around the screw tips-a biomechanically validated surrogate for the risk of cyclic screw cutout failure-was defined as the main outcome measure. The angles of the 6 proximal locking screws were optimized via parametric analysis for each humerus individually, resulting in subject-specific screw orientations (SSO). The average peri-implant strains of the SSO were statistically compared with the previously reported cohort-specific (CSO) and original PHILOS screw orientations (PSO) for females vs. males. RESULTS The optimized SSO significantly reduced the peri-screw bone strain vs. CSO (6.8% ± 4.0%, P = .006) and PSO (25.24% ± 7.93%, P < .001), indicating lower cutout risk for subject-specific configurations. The benefits of SSO vs. PSO were significantly higher for women than men. CONCLUSION The findings of this study suggest that subject-specific optimization of the locking screw orientations could lead to lower cutout risk and improved PHF fixation. These computer simulation results require biomechanical and clinical corroboration. Further studies are needed to evaluate whether the potential benefit in stability could justify the increased efforts related to implementation of individualized implants. Nevertheless, computational exploration of the biomechanical factors influencing the outcome of fracture fixations could help better understand the fixation failures and reduce their incidence.
Collapse
|
42
|
Abstract
BACKGROUND Tarsometatarsal (TMT) arthrodesis is a common operative procedure for end-stage arthritis of the TMT joints. To date, there is no consensus on the best fixation technique for TMT arthrodesis and which joints should be included. METHODS Thirty fresh-frozen feet were divided into one group (15 feet) in which TMT joints I-III were fused with a lag screw and locking plate and a second group (15 feet) in which TMT joints I-III were fused with 2 crossing lag screws. The arthrodesis was performed stepwise with evaluation of mobility between the metatarsal and cuneiform bones after every application or removal of a lag screw or locking plate. RESULTS Isolated lag-screw arthrodesis of the TMT I-III joints led to significantly increased stability in every joint (P < .05). Additional application of a locking plate caused further stability in every TMT joint (P < .05). An additional crossed lag screw did not significantly increase rigidity of the TMT II and III joints (P > .05). An IM screw did not influence the stability of the fused TMT joints. For TMT III arthrodesis, lag-screw and locking plate constructs were superior to crossed lag-screw fixation (P < .05). TMT I fusion does not support stability after TMT II and III arthrodesis. CONCLUSION Each fixation technique provided sufficient stabilization of the TMT joints. Use of a lag screw plus locking plate might be superior to crossed screw fixation. An additional TMT I and/or III arthrodesis did not increase stability of an isolated TMT II arthrodesis. CLINICAL RELEVANCE We report the first biomechanical evaluation of TMT I-III arthrodesis. Our results may help surgeons to choose among osteosynthesis techniques and which joints to include in performing arthrodesis of TMT I-III joints.
Collapse
|
43
|
Operative choice for subtrochanteric femoral fracture in school-aged children: Triple elastic stable intramedullary nail versus locking plate. Front Pediatr 2022; 10:894262. [PMID: 35958179 PMCID: PMC9360405 DOI: 10.3389/fped.2022.894262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 07/01/2022] [Indexed: 12/04/2022] Open
Abstract
BACKGROUND The management strategy of subtrochanteric fractures remains controversial, and triple elastic stable intramedullary nail (ESIN) has not been reported for pediatric subtrochanteric fractures. This study aimed to compare the clinical effects of treating school-aged children with subtrochanteric fractures with triple ESINs versus locking plates. METHODS We conducted a retrospective review of pediatric patients with subtrochanteric femoral fracture receiving either triple ESINs (TE) or locking plates (LPs) between January 2010 and January 2018. Sixteen patients in each group with matched age, sex, and fracture characteristics were included in the study. The preoperative data, including baseline information of the patients, fracture pattern, and types of surgical procedure, were collected from the hospital database. Patients were followed-up at the outpatient clinic in the 3rd month, 6th month, 12th month, and annually afterward. Hardware removal was performed at 9 - 18 months after the primary surgery. RESULTS In all, 16 patients (8.4 ± 1.5-year-old, 7 boys, 9 girls) in the TE group and 16 patients (8.4 ± 1.4-year-old, 7 boys, 9 girls) in the LP group were included. There was significantly less operative time, reduced estimated blood loss, and shortened hospital stay for the TE as compared with the LP (P < 0.001). However, higher fluoroscopy frequency was observed in the TE group than in the LP group (P < 0.001). The time to union was faster in the TE group than in the LP group (P = 0.031). However, the angulation was higher in the TE group (3.2 ± 0.6) than the LP group (1.8 ± 0.5), and the incidence of implant prominence was higher in the TE group (7/16, 43.8%) than the LP group (1/16, 6.3%). CONCLUSION Compared with the locking plates, triple ESINs demonstrated significantly less operative time, reduced estimated blood loss, and shortened hospital stay. Besides, both TE and LP groups produced satisfactory outcomes in school-aged children with subtrochanteric fractures. Therefore, TE remains a feasible choice for subtrochanteric fractures in school-aged children.
Collapse
|
44
|
A New Surgical Technique and Clinical Outcomes of Operated Proximal Metadiaphyseal Humeral Fractures and Nonunions With the Use of Reversed Anatomic Distal Femoral Locking Plate. Cureus 2021; 13:e18309. [PMID: 34722081 PMCID: PMC8548934 DOI: 10.7759/cureus.18309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/26/2021] [Indexed: 12/04/2022] Open
Abstract
Introduction Proximal humeral fractures complicated with metaphyseal and diaphyseal extension are usually treated operatively with 3.5 mm long anatomic proximal humerus plates. However, frequently these comminuted and segmental fracture types may be associated with delayed union, nonunion, and/or plate failure. We present a technique for addressing this fracture pattern by using an anatomic contralateral 4.5 mm distal femoral plate in a reversed fashion. Methods Eleven patients (eight women and three men) with a mean age of 70 years (range, 52 to 84 years) were operated on with the described technique. The dominant hand was involved in seven out of 11 patients. There were seven acute metadiaphyseal fractures and four nonunions. In one patient, humeral shaft nonunion was associated with segmental metadiaphyseal defect and a free fibular graft was applied. Results All fractures healed and patients regained almost normal function of the affected shoulder and upper limb. Shoulder abduction and forward elevation ranged from 80 to 110 degrees (mean, 97 degrees) and 90 to 120 degrees (mean, 102 degrees), respectively. The disabilities of the arm, shoulder and hand (DASH) score varied from 6 to 11 points (median 8). No major trauma or systemic complications were recorded. Conclusion The morphology, strength, and characteristics of the plate could effectively conform to the anatomy of the proximal humerus and offer adequate stability for fracture union. The described technique is more useful in case of osteoporosis and/or presence of previous failed internal fixation that further compromise the vascularization and the mechanical properties of the bone.
Collapse
|
45
|
Functional and Radiological Outcome in Distal Third Humerus Fracture Treated with Extra-articular Locking Plate: A Multicentric Retrospective Study. J Pharm Bioallied Sci 2021; 13:S1483-S1487. [PMID: 35018015 PMCID: PMC8686899 DOI: 10.4103/jpbs.jpbs_263_21] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 04/16/2021] [Accepted: 05/09/2021] [Indexed: 11/27/2022] Open
Abstract
INTRODUCTION The optimal method for fixation of extra-articular distal humerus fractures poses a management dilemma. Although various plate configurations have been proposed, anatomic shaped extra-articular distal humerus locking plates (EADHPs) have emerged as a viable solution for these complex injuries. We assessed functional and radiologic outcomes in our retrospective case series of extra-articular distal humerus fractures managed with these plates at different centers in Cuttack, Odisha. MATERIALS AND METHODS One hundred and ten patients of extra-articular distal humerus fractures, who were operated at various trauma centers between January 2012 and December 2020, were identified. After exclusion, 100 patients were available for the final assessment. All patients were operated with the triceps-reflecting modified posterior approach. Regular functional-radiologic follow-up was done evaluating elbow functionality, fracture union, secondary displacement, nonunion, implant failure, and any complications; Mayo Elbow Performance Score (MEPS) was used for the final functional assessment. RESULTS Sixty-seven percent of male and 33% of female patients constituted the study group, who had an average follow-up of 18 months. Preoperatively three patients and postoperatively one patient had radial nerve palsy; all had neurapraxia and recovered completely. Overall, 95% of patients were adjudged to have complete radiological union within 3 months; 6% of patients developed nonunion. The mean flexion achieved was 123 + 22, and the mean extension was 4.031 + 6.50; five patients with head injury developed flexion deformity of 45. The average MEPS at the final follow-up was 91 + 9.8. CONCLUSION Stable reconstruction and early initiation of physiotherapy are utilitarian to envision optimal outcome; the use of precontoured EADHPs has yielded satisfactory results with minimal complications in our hands.
Collapse
|
46
|
[Current status and progress of locking plate in the treatment of distal femoral comminuted fracture]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:1352-1356. [PMID: 34651492 PMCID: PMC8505932 DOI: 10.7507/1002-1892.202102050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 06/27/2021] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To review the current status and progress of locking plate for the treatment of distal femoral comminuted fractures. METHODS The related literature was extensively reviewed to summarize the current status and progress in the treatment of distal femoral comminuted fracture with locking plate from four aspects: the current treatment situation, the shortcomings of locking plate and countermeasures, the progress of locking technology, locking plate and digital orthopedic technology. RESULTS Treatment of distal femoral comminuted fractures is challenging. Locking plates, the most commonly used fixation for distal femoral comminuted fractures, still face a high rate of treatment failure. Double plates can improve the mechanical stability of comminuted fractures, but specific quantitative criteria are still lacking for when to choose double plates for fixation. The far cortial locking screw has shown good application value in improving the micro-movement and promoting the growth of callus. The biphasic plating is a development of the traditional locking plate, but needs further clinical examination. As an auxiliary means, digital orthopedic technology shows a good application prospect. CONCLUSION The inherent defect of locking plate is a factor that affects the prognosis of distal femoral comminuted fracture. The optimization of locking technology combined with digital orthopedic technology is expected to reduce the failure rate of treatment of distal femoral comminuted fracture.
Collapse
|
47
|
MutiLoc Nail Versus Philos Plate in Treating Proximal Humeral Fractures: A Retrospective Study Among the Alderly. Geriatr Orthop Surg Rehabil 2021; 12:21514593211043961. [PMID: 34595046 PMCID: PMC8477691 DOI: 10.1177/21514593211043961] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 08/15/2021] [Accepted: 08/17/2021] [Indexed: 01/11/2023] Open
Abstract
Background Proximal humeral fractures (PHFs) account for 4–5% of all fractures in the elderly. There is still a controversy among the treatments in the displaced PHFs. Our aim was to explore the clinical outcome of PHFs with the treatment of MultiLoc nail or Philos plate in the elderly patients. Methods A total of 82 sustained elderly patients with PHFs were finally recruited between Dec 2016 and Dec 2017. 34 patients were treated with MultiLoc nail and 48 patients were treated with Philos plate. The demographics, fracture types, blood loss, operation time, union time, postoperative complications, visual analog scores (VASs), Constant scores, American Shoulder and Elbow Scores (ASESs), and neck-shaft-angle (NSA) between the two groups were compared. Results No differences were observed in the demographics, fracture types, VAS, Constant scores, and ASES scores between the two groups at final follow-up. Compared with the plate group, the blood loss, operation time, and union time were significantly lower in the nail group (all P < .05). The rate of general complications was 54.17% in the plate group, which was higher than that in the nail group (26.47%, P = .01). Three patients experienced reoperation in the plate group (3/48; 6.25%), but none in the nail group. Although there were no significant differences in intraoperative NSA between the two groups, the NSA at final follow-up in the nail group was much higher than the plate group (137.55 ± 5.53°vs 134.47 ± 5.92°, P = .02). Conclusions Multiloc intramedullary nail showed the similar effectiveness of final VAS, final Constant scores, and ASES scores in PHFs treatment with Philos plate. However, MultiLoc nail is superior to Philos plate in blood loss, operation time, complications, reoperation rate, and the change of NSA.
Collapse
|
48
|
Biomechanical Comparison of Tibial Plateau Leveling Osteotomy Performed With a Novel Titanium Alloy Locking Plate Construct vs. an Established Stainless-Steel Locking Plate Construct. Front Vet Sci 2021; 8:698159. [PMID: 34568473 PMCID: PMC8455938 DOI: 10.3389/fvets.2021.698159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 06/24/2021] [Indexed: 11/14/2022] Open
Abstract
A novel canine tibial plateau leveling osteotomy (TPLO) fixation device was recently developed with design features such as titanium alloy (TA) material, distal monocortical screw fixation, and a point contact undersurface specifically targeted to reduce surgical site infection rates by ensuring tissue perfusion under the plate. The strength of the novel TPLO construct was compared with that of a predicate stainless steel (SS) locking plate construct with bicortical screws in 16 paired cadaveric canine limbs. The mean loads to failure were 716.71 ± 109.50 N (range 455.69–839.69 N) and 629.50 ± 176.83 N (range 272.58–856.18 N) in the TA and SS groups, respectively. The average ratio of the loads to failure of the paired specimens was 1.18 (p = 0.031). No failure of the TA constructs involved the distal fixation with monocortical screws. Substantial mechanical equivalence of this novel TA monocortical/bicortical fixation construct to an established SS bicortical screw fixation construct is demonstrated. Clinical investigation of potential merits of this novel TA, monocortical/bicortical locking screw/plate system is now warranted.
Collapse
|
49
|
Cancellous bone allograft is comparable to fibular strut allograft for augmentation in three- or four-part proximal humeral fractures. J Shoulder Elbow Surg 2021; 30:2065-2072. [PMID: 33484831 DOI: 10.1016/j.jse.2020.11.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 11/16/2020] [Accepted: 11/25/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Bone grafts have been used for augmentation and improving stability of reduced fractures in proximal humeral fractures. The aim of this study was to analyze the clinical and radiological outcomes after the use of cancellous bone allografts (CAs) for augmentation in 3- or 4-part proximal humeral fractures, and compare with fibular strut allografts (FAs). METHODS Between November 2016 and February 2018, 55 patients, followed for at least 1 year, with 3- or 4-part proximal humeral fractures fixed with locking plates were included and grouped according to the type of allograft bone used for augmentation. In this retrospective analysis, we assessed and compared the clinical and radiological outcomes of the 2 groups, using the visual analog scale score, the Constant-Murley score (CMS), the disability of the arm, shoulder, and hand (DASH) score, the range of movement, neck-shaft angle (NSA), humeral head height (HHH), and the changes of NSA and HHH, as well as recording any complications. The repeatedly measured clinical and radiological outcomes were analyzed by linear mixed models. The differences in outcomes between groups at the final follow-up were compared using Student's t test. RESULTS There were 28 patients in the CA group and 27 patients in the FA group with an average follow-up of 14.5 months. The mean age of all patients was 64 (36-86). Nonsignificant group effects were observed on CMS (β = -8.792, P = .216), DASH (β = 1.329, P = .094), NSA (β = 1.432, P = .752), and HHH (β = 1.660, P = .628). At the final follow-up, the patients in the CA group showed no significant differences in visual analog scale (1.8 vs. 2.2, P = .276), CMS (81.5 vs. 75.4, P = .072), and DASH (11.0 vs. 13.5, P = .235) scores compared with the FA group. There were no significant differences in the change of NSA (6 vs. 4, P = .387) or HHH (1 vs. 2, P = .261). CONCLUSIONS Patients with 3- or 4-part proximal humeral fractures treated with locking plates combined with CAs have good clinical and radiographic outcomes, similar to those treated with FAs.
Collapse
|
50
|
Abstract
Level of Evidence: Level V, expert opinion.
Collapse
|