Oxygenation saturation index in neonatal hypoxemic respiratory failure.
Pediatr Int 2024;
66:e15753. [PMID:
38641936 DOI:
10.1111/ped.15753]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 12/03/2023] [Accepted: 01/16/2024] [Indexed: 04/21/2024]
Abstract
BACKGROUND
This study aimed to assess the validity of the oxygenation saturation index (OSI) and the ratio of oxygen saturation to the fraction of inspired oxygen (FIO2) (S/F ratio) with percutaneous oxygen saturation (OSISpO2 and the Sp/F ratio) and to evaluate the correlation between these values and the oxygen index (OI). It also determined their cut-off values for predicting OI in accordance with neonatal hypoxic respiratory failure severity.
METHODS
We reviewed the data of 77 neonates (gestational age 31.7 ± 6.1 weeks; birthweight, 1768 ± 983 g) requiring invasive mechanical ventilation between 2013 and 2020, 1233 arterial blood gas samples in total. We calculated the OI, OSISpO2, OSI with arterial oxygen saturation (SaO2) (OSISaO2), Sp/F ratio, and the ratio of SaO2 to FIO2 (Sa/F ratio).
RESULTS
The regression and Bland-Altman analysis showed good agreement between OSISpO2 or the Sp/F ratio and OSISaO2 or the Sa/F ratio. Although a significant positive correlation was found between OSISpO2 and OI, OSISpO2 was overestimated in SpO2 > 98% with a higher slope of the fitted regression line than that below 98% of SpO2. Furthermore, receiver-operating characteristic curve analysis using only SpO2 ≤ 98% samples showed that the optimal cut-off points of OSISpO2 and the Sp/F ratio for predicting OI were: OI 5, 3.0 and 332; OI 10, 5.3 and 231; OI 15, 7.7 and 108; OI 20, 11.0 and 149; and OI 25, 17.1 and 103, respectively.
CONCLUSION
The cut-off OSISpO2 and Sp/F ratio values could allow continuous monitoring for oxygenation changes in neonates with the potential for wider clinical applications.
Collapse