1
|
Massaroni C, Nicolò A, Lo Presti D, Sacchetti M, Silvestri S, Schena E. Contact-Based Methods for Measuring Respiratory Rate. SENSORS (BASEL, SWITZERLAND) 2019; 19:E908. [PMID: 30795595 PMCID: PMC6413190 DOI: 10.3390/s19040908] [Citation(s) in RCA: 137] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 02/15/2019] [Accepted: 02/17/2019] [Indexed: 01/05/2023]
Abstract
There is an ever-growing demand for measuring respiratory variables during a variety of applications, including monitoring in clinical and occupational settings, and during sporting activities and exercise. Special attention is devoted to the monitoring of respiratory rate because it is a vital sign, which responds to a variety of stressors. There are different methods for measuring respiratory rate, which can be classed as contact-based or contactless. The present paper provides an overview of the currently available contact-based methods for measuring respiratory rate. For these methods, the sensing element (or part of the instrument containing it) is attached to the subject's body. Methods based upon the recording of respiratory airflow, sounds, air temperature, air humidity, air components, chest wall movements, and modulation of the cardiac activity are presented. Working principles, metrological characteristics, and applications in the respiratory monitoring field are presented to explore potential development and applicability for each method.
Collapse
|
Review |
6 |
137 |
2
|
Tipton MJ, Harper A, Paton JFR, Costello JT. The human ventilatory response to stress: rate or depth? J Physiol 2017. [PMID: 28650070 DOI: 10.1113/jp274596] [Citation(s) in RCA: 114] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Many stressors cause an increase in ventilation in humans. This is predominantly reported as an increase in minute ventilation (V̇E). But, the same V̇E can be achieved by a wide variety of changes in the depth (tidal volume, VT ) and number of breaths (respiratory frequency, ƒR ). This review investigates the impact of stressors including: cold, heat, hypoxia, pain and panic on the contributions of ƒR and VT to V̇E to see if they differ with different stressors. Where possible we also consider the potential mechanisms that underpin the responses identified, and propose mechanisms by which differences in ƒR and VT are mediated. Our aim being to consider if there is an overall differential control of ƒR and VT that applies in a wide range of conditions. We consider moderating factors, including exercise, sex, intensity and duration of stimuli. For the stressors reviewed, as the stress becomes extreme V̇E generally becomes increased more by ƒR than VT . We also present some tentative evidence that the pattern of ƒR and VT could provide some useful diagnostic information for a variety of clinical conditions. In The Physiological Society's year of 'Making Sense of Stress', this review has wide-ranging implications that are not limited to one discipline, but are integrative and relevant for physiology, psychophysiology, neuroscience and pathophysiology.
Collapse
|
Review |
8 |
114 |
3
|
Nicolò A, Massaroni C, Schena E, Sacchetti M. The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6396. [PMID: 33182463 PMCID: PMC7665156 DOI: 10.3390/s20216396] [Citation(s) in RCA: 114] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 11/05/2020] [Accepted: 11/08/2020] [Indexed: 12/11/2022]
Abstract
Respiratory rate is a fundamental vital sign that is sensitive to different pathological conditions (e.g., adverse cardiac events, pneumonia, and clinical deterioration) and stressors, including emotional stress, cognitive load, heat, cold, physical effort, and exercise-induced fatigue. The sensitivity of respiratory rate to these conditions is superior compared to that of most of the other vital signs, and the abundance of suitable technological solutions measuring respiratory rate has important implications for healthcare, occupational settings, and sport. However, respiratory rate is still too often not routinely monitored in these fields of use. This review presents a multidisciplinary approach to respiratory monitoring, with the aim to improve the development and efficacy of respiratory monitoring services. We have identified thirteen monitoring goals where the use of the respiratory rate is invaluable, and for each of them we have described suitable sensors and techniques to monitor respiratory rate in specific measurement scenarios. We have also provided a physiological rationale corroborating the importance of respiratory rate monitoring and an original multidisciplinary framework for the development of respiratory monitoring services. This review is expected to advance the field of respiratory monitoring and favor synergies between different disciplines to accomplish this goal.
Collapse
|
Review |
5 |
114 |
4
|
Baker-Herman TL, Mitchell GS. Determinants of frequency long-term facilitation following acute intermittent hypoxia in vagotomized rats. Respir Physiol Neurobiol 2008; 162:8-17. [PMID: 18450525 PMCID: PMC2504692 DOI: 10.1016/j.resp.2008.03.005] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2008] [Revised: 03/11/2008] [Accepted: 03/12/2008] [Indexed: 10/22/2022]
Abstract
Acute intermittent (AIH), but not acute sustained hypoxia (ASH) elicits a form of respiratory plasticity known as long-term facilitation (LTF). In anesthetized rats, LTF is expressed as increased respiratory-related nerve burst amplitude, with variable effects on burst frequency. We analyzed a large data set from multiple investigators using the same experimental protocol to determine factors influencing frequency LTF. Our meta-analysis revealed that AIH elicits both phrenic amplitude and frequency LTF in anesthetized and vagotomized rats, but frequency LTF is small in comparison with amplitude LTF (12% versus 60%, respectively). ASH elicits a small, but significant frequency and amplitude LTF (8% and 10%, respectively) that is not significantly different than controls. Similar to all published reports, analysis of this large data set confirms that phrenic amplitude LTF following AIH is significantly greater than ASH. Multiple regression analysis revealed a strong correlation between baseline burst frequency and frequency LTF. Variations in baseline burst frequency may contribute to variation in frequency LTF and may underlie the apparent effects of some drug treatments.
Collapse
|
Research Support, N.I.H., Extramural |
17 |
79 |
5
|
Rohr AC. The health significance of gas- and particle-phase terpene oxidation products: a review. ENVIRONMENT INTERNATIONAL 2013; 60:145-162. [PMID: 24036325 DOI: 10.1016/j.envint.2013.08.002] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Revised: 08/01/2013] [Accepted: 08/02/2013] [Indexed: 06/02/2023]
Abstract
The reactions between terpenes and ozone (or other oxidants) produce a wide variety of both gas- and particle-phase products. Terpenes are biogenic volatile organic compounds (VOCs) that are also contained in many consumer products. Ozone is present indoors since it infiltrates into the indoor environment and is emitted by some office and consumer equipment. Some of the gaseous products formed are irritating to biological tissues, while the condensed-phase products have received attention due to their contribution to ambient fine particulate matter (PM2.5) and its respective health significance. Despite common scientific questions, the indoor and ambient air research communities have tended to operate in isolation regarding this topic. This review critically evaluates the literature related to terpene oxidation products and attempts to synthesize results of indoor and ambient air studies to better understand the health significance of these materials and identify knowledge gaps. The review documents the results of a literature search covering terpene oxidation chemistry, epidemiological, toxicological, and controlled human exposure studies, as well as health studies focused more generically on secondary organic aerosol (SOA). The literature shows a clear role for gas-phase terpene oxidation products in adverse airway effects at high concentrations; however, whether these effects occur at more environmentally relevant levels is unclear. The evidence for toxicity of particle-phase products is less conclusive. Knowledge gaps and future research needs are outlined, and include the need for more consistency in study designs, incorporation of reaction product measurements into epidemiological studies conducted in both indoor and ambient settings, and more focused research on the toxicity of SOA, especially SOA of biogenic origin.
Collapse
|
Review |
12 |
63 |
6
|
Roberson-Nay R, Klein DF, Klein RG, Mannuzza S, Moulton JL, Guardino M, Pine DS. Carbon dioxide hypersensitivity in separation-anxious offspring of parents with panic disorder. Biol Psychiatry 2010; 67:1171-7. [PMID: 20172505 PMCID: PMC3617557 DOI: 10.1016/j.biopsych.2009.12.014] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2009] [Revised: 11/26/2009] [Accepted: 12/11/2009] [Indexed: 10/19/2022]
Abstract
BACKGROUND Similar patterns of vulnerability to carbon dioxide (CO(2)) inhalation have been reported in adults with panic disorder (PD) and children with separation anxiety disorder (SAD), suggesting a link between the adult and child conditions. This study examines the influence of familial risk for PD on CO(2) responses in children with SAD. We hypothesized that offspring with SAD of parents with PD would have distinct CO(2) responses. METHODS Two hundred twelve 9- to 20-year-old offspring of parents with or without PD were exposed to maintained 5% CO(2) inhalation in the participants' homes. Anxiety symptoms, panic attacks, and respiratory physiology (respiratory frequency and tidal volume) were monitored during baseline and 15-min maintained CO(2) breathing. RESULTS As hypothesized, significant offspring SAD x parent PD interactions were obtained for anxiety symptoms, respiratory frequency, tidal volume, and a panting index during CO(2) inhalation. Offspring with both SAD and parental PD exhibited more anxiety symptoms at termination of 5% CO(2) breathing than the other offspring groups and had the most extreme values on measures of respiratory physiology. CONCLUSIONS Youth with both SAD and parental PD have respiratory responses to CO(2) similar to adult PD. They might be a subtype of SAD at particularly high risk for adult PD.
Collapse
|
Research Support, N.I.H., Extramural |
15 |
43 |
7
|
Salvati GGS, Morais Júnior NN, Melo ACS, Vilela RR, Cardoso FF, Aronovich M, Pereira RAN, Pereira MN. Response of lactating cows to live yeast supplementation during summer. J Dairy Sci 2015; 98:4062-73. [PMID: 25795491 DOI: 10.3168/jds.2014-9215] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2023]
Abstract
Dairy cows experiencing heat stress have reduced intake and increased reliance on glucose, making feeding strategies capable of improving diet digestibility plausible for improving postrumen nutrient flow and performance. The effect of yeast on digestion and performance of lactating cows during the warm summer months of southeastern Brazil was evaluated. Cows were individually fed in tie stalls and temperature-humidity index was above 68 during 75.6% of the experiment. Twenty-eight Holstein cows (207±87 d in milk) received a standard diet for 14 d and then a treatment for 70 d, in a covariate-adjusted, randomized block design with repeated measures over time. Treatments were yeast (Saccharomyces cerevisiae) or control. Yeast was top dressed to the diet in the morning, equivalent to 25×10(10) cfu of live cells and 5×10(10) cfu of dead cells. The diet contained corn silage (37.7%), Tifton silage (7.1%), raw soybeans (4.1%), soybean meal (16.5%), finely ground corn (20.7%), and citrus pulp (11.9%). Yeast increased milk (26.7 vs. 25.4 kg/d) and solids yield (3.06 vs. 2.92 kg/d), especially lactose. Response in milk yield was consistent over time and started at d 5. The daily intake of digestible OM, total-tract digestibility of nutrients, urinary allantoin excretion, chewing pattern throughout the day, and dry matter intake did not respond to yeast. A trend was observed for increased plasma glucose with yeast (62.9 vs. 57.3mg/dL), lowered respiratory frequency (48 vs. 56 breaths/min), and increased plasma niacin content (1.31 vs. 1.22 µg/mL), though cows had similar rectal temperature. Ruminal lactate and butyrate as proportions of ruminal organic acids were reduced by yeast, but no effects on other organic acids, ruminal pH, or protozoa content were detected. Plasma urea N over 24h was increased by yeast. On d 72 to 74, citrus pulp was abruptly replaced with finely ground corn to induce acidosis. The increased load of starch increased dry matter intake between 0700 and 1300 h, jugular blood partial pressure of CO2, HCO3-, and base excess, and decreased blood pH for both treatments. The yeast treatment had a higher blood pH compared with the control, 7.34, and 7.31, respectively. Yeast supplementation improved lactation performance of dairy cows under heat stress. Improvement in lactation performance apparently involved the regulation of body homeothermia, rather than improved digestibility.
Collapse
|
|
10 |
31 |
8
|
Lo Presti D, Carnevale A, D’Abbraccio J, Massari L, Massaroni C, Sabbadini R, Zaltieri M, Di Tocco J, Bravi M, Miccinilli S, Sterzi S, Longo UG, Denaro V, Caponero MA, Formica D, Oddo CM, Schena E. A Multi-Parametric Wearable System to Monitor Neck Movements and Respiratory Frequency of Computer Workers. SENSORS (BASEL, SWITZERLAND) 2020; 20:E536. [PMID: 31963696 PMCID: PMC7014540 DOI: 10.3390/s20020536] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/15/2020] [Accepted: 01/16/2020] [Indexed: 11/29/2022]
Abstract
Musculoskeletal disorders are the most common form of occupational ill-health. Neck pain is one of the most prevalent musculoskeletal disorders experienced by computer workers. Wrong postural habits and non-compliance of the workstation to ergonomics guidelines are the leading causes of neck pain. These factors may also alter respiratory functions. Health and safety interventions can reduce neck pain and, more generally, the symptoms of musculoskeletal disorders and reduce the consequent economic burden. In this work, a multi-parametric wearable system based on two fiber Bragg grating sensors is proposed for monitoring neck movements and breathing activity of computer workers. The sensing elements were positioned on the neck, in the frontal and sagittal planes, to monitor: (i) flexion-extension and axial rotation repetitions, and (ii) respiratory frequency. In this pilot study, five volunteers were enrolled and performed five repetitions of both flexion-extension and axial rotation, and ten breaths of both quite breathing and tachypnea. Results showed the good performances of the proposed system in monitoring the aforementioned parameters when compared to optical reference systems. The wearable system is able to well-match the trend in time of the neck movements (both flexion-extension and axial rotation) and to estimate mean and breath-by-breath respiratory frequency values with percentage errors ≤6.09% and ≤1.90%, during quiet breathing and tachypnea, respectively.
Collapse
|
research-article |
5 |
28 |
9
|
Nicolò A, Girardi M, Sacchetti M. Control of the depth and rate of breathing: metabolic vs. non-metabolic inputs. J Physiol 2017; 595:6363-6364. [PMID: 28766719 DOI: 10.1113/jp275013] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
|
Comment |
8 |
21 |
10
|
Nicolò A, Marcora SM, Sacchetti M. Time to reconsider how ventilation is regulated above the respiratory compensation point during incremental exercise. J Appl Physiol (1985) 2020; 128:1447-1449. [PMID: 32053402 DOI: 10.1152/japplphysiol.00814.2019] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
Journal Article |
5 |
19 |
11
|
Martos-Sitcha JA, Sosa J, Ramos-Valido D, Bravo FJ, Carmona-Duarte C, Gomes HL, Calduch-Giner JÀ, Cabruja E, Vega A, Ferrer MÁ, Lozano M, Montiel-Nelson JA, Afonso JM, Pérez-Sánchez J. Ultra-Low Power Sensor Devices for Monitoring Physical Activity and Respiratory Frequency in Farmed Fish. Front Physiol 2019; 10:667. [PMID: 31191358 PMCID: PMC6548888 DOI: 10.3389/fphys.2019.00667] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 05/09/2019] [Indexed: 01/31/2023] Open
Abstract
Integration of technological solutions aims to improve accuracy, precision and repeatability in farming operations, and biosensor devices are increasingly used for understanding basic biology during livestock production. The aim of this study was to design and validate a miniaturized tri-axial accelerometer for non-invasive monitoring of farmed fish with re-programmable schedule protocols. The current device (AE-FishBIT v.1s) is a small (14 mm × 7 mm × 7 mm), stand-alone system with a total mass of 600 mg, which allows monitoring animals from 30 to 35 g onwards. The device was attached to the operculum of gilthead sea bream (Sparus aurata) and European sea bass (Dicentrarchus labrax) juveniles for monitoring their physical activity by measurements of movement accelerations in x- and y-axes, while records of operculum beats (z-axis) served as a measurement of respiratory frequency. Data post-processing of exercised fish in swimming test chambers revealed an exponential increase of fish accelerations with the increase of fish speed from 1 body-length to 4 body-lengths per second, while a close relationship between oxygen consumption (MO2) and opercular frequency was consistently found. Preliminary tests in free-swimming fish kept in rearing tanks also showed that device data recording was able to detect changes in daily fish activity. The usefulness of low computational load for data pre-processing with on-board algorithms was verified from low to submaximal exercise, increasing this procedure the autonomy of the system up to 6 h of data recording with different programmable schedules. Visual observations regarding tissue damage, feeding behavior and circulating levels of stress markers (cortisol, glucose, and lactate) did not reveal at short term a negative impact of device tagging. Reduced plasma levels of triglycerides revealed a transient inhibition of feed intake in small fish (sea bream 50-90 g, sea bass 100-200 g), but this disturbance was not detected in larger fish. All this considered together is the proof of concept that miniaturized devices are suitable for non-invasive and reliable metabolic phenotyping of farmed fish to improve their overall performance and welfare. Further work is underway for improving the attachment procedure and the full device packaging.
Collapse
|
|
6 |
12 |
12
|
Enhanced Breathing Pattern Detection during Running Using Wearable Sensors. SENSORS 2021; 21:s21165606. [PMID: 34451048 PMCID: PMC8402371 DOI: 10.3390/s21165606] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 08/16/2021] [Accepted: 08/18/2021] [Indexed: 12/28/2022]
Abstract
Breathing pattern (BP) is related to key psychophysiological and performance variables during exercise. Modern wearable sensors and data analysis techniques facilitate BP analysis during running but are lacking crucial validation steps in their deployment. Thus, we sought to evaluate a wearable garment with respiratory inductance plethysmography (RIP) sensors in combination with a custom-built algorithm versus a reference spirometry system to determine its concurrent validity in detecting flow reversals (FR) and BP. Twelve runners completed an incremental running protocol to exhaustion with synchronized spirometry and RIP sensors. An algorithm was developed to filter, segment, and enrich the RIP data for FR and BP estimation. The algorithm successfully identified over 99% of FR with an average time lag of 0.018 s (−0.067,0.104) after the reference system. Breathing rate (BR) estimation had low mean absolute percent error (MAPE = 2.74 [0.00,5.99]), but other BP components had variable accuracy. The proposed system is valid and practically useful for applications of BP assessment in the field, especially when measuring abrupt changes in BR. More studies are needed to improve BP timing estimation and utilize abdominal RIP during running.
Collapse
|
|
4 |
11 |
13
|
Romano C, Nicolò A, Innocenti L, Bravi M, Miccinilli S, Sterzi S, Sacchetti M, Schena E, Massaroni C. Respiratory Rate Estimation during Walking and Running Using Breathing Sounds Recorded with a Microphone. BIOSENSORS 2023; 13:637. [PMID: 37367002 DOI: 10.3390/bios13060637] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 05/30/2023] [Accepted: 06/05/2023] [Indexed: 06/28/2023]
Abstract
Emerging evidence suggests that respiratory frequency (fR) is a valid marker of physical effort. This has stimulated interest in developing devices that allow athletes and exercise practitioners to monitor this vital sign. The numerous technical challenges posed by breathing monitoring in sporting scenarios (e.g., motion artifacts) require careful consideration of the variety of sensors potentially suitable for this purpose. Despite being less prone to motion artifacts than other sensors (e.g., strain sensors), microphone sensors have received limited attention so far. This paper proposes the use of a microphone embedded in a facemask for estimating fR from breath sounds during walking and running. fR was estimated in the time domain as the time elapsed between consecutive exhalation events retrieved from breathing sounds every 30 s. Data were collected from ten healthy subjects (both males and females) at rest and during walking (at 3 km/h and 6 km/h) and running (at 9 km/h and 12 km/h) activities. The reference respiratory signal was recorded with an orifice flowmeter. The mean absolute error (MAE), the mean of differences (MOD), and the limits of agreements (LOAs) were computed separately for each condition. Relatively good agreement was found between the proposed system and the reference system, with MAE and MOD values increasing with the increase in exercise intensity and ambient noise up to a maximum of 3.8 bpm (breaths per minute) and -2.0 bpm, respectively, during running at 12 km/h. When considering all the conditions together, we found an MAE of 1.7 bpm and an MOD ± LOAs of -0.24 ± 5.07 bpm. These findings suggest that microphone sensors can be considered among the suitable options for estimating fR during exercise.
Collapse
|
|
2 |
3 |
14
|
Effects of respiratory motion on volumetric and positional difference of GTV in lung cancer based on 3DCT and 4DCT scanning. Oncol Lett 2019; 17:2388-2392. [PMID: 30675304 PMCID: PMC6341872 DOI: 10.3892/ol.2018.9844] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Accepted: 11/30/2018] [Indexed: 11/29/2022] Open
Abstract
Differences in gross target volume (GTV) and central point positions among moving lung cancer models constructed by CT scanning at different frequencies were compared, in order to explore the effect of different respiratory frequencies on the GTV constructions in moving lung tumors. Eight models in different shapes and sizes were established to stimulate lung tumors. The three-dimensional computed tomography (3DCT) and four-dimensional computed tomography (4DCT) scanning were performed at 10, 15 and 20 times/min in different models. Differences in GTV volumes and central point positions at different motion frequencies were compared by means of GTV3Ds (GTV3D-10, GTV3D-15, GTV3D-20) and IGTV4Ds (IGTV4D-10, IGTV4D-15, IGTV4D-20). Volumes of GTV3D-10, GTV3D-15, GTV3D-20 were 12.41±14.26, 10.38±11.18 and 12.50±15.23 cm3 respectively (P=0.687). Central point coordinates in the x-axis direction were −8.16±96.21, −8.57±96.08 and −8.56±95.73 respectively (P=0.968). Central point coordinates in the y-axis direction were 108.22±25.03, 110.41±22.47 and 109.04±24.24 (P=0.028). Central point coordinates in the z-axis direction were 65.19±13.68, 65.43±13.40 and 65.38±13.17 (P=0.902). The difference was significant in the y-axis direction (P=0.028). Volumes of IGTV4D-10, IGTV4D-15, IGTV4D-20 were 17.78±19.42, 17.43±19.56 and 17.44±18.80 cm3 (P=0.417). Central point coordinates in the x-axis direction were −7.73±95.93, −7.86±95.56 and −7.92±95.14 (P=0.325). Central point coordinates in the y-axis direction were 109.41±24.54, 109.60±24.13 and 109.16±24.28 (P=0.525). Central point coordinates in the z-axis direction were 65.52±13.31, 65.59±13.39 and 65.51±13.34 (P=0.093). However, the central point position of GTV in the head and foot direction by 3DCT scanning was severely affected by the respiratory frequency.
Collapse
|
|
6 |
1 |
15
|
How to Investigate the Effect of Music on Breathing during Exercise: Methodology and Tools. SENSORS 2022; 22:s22062351. [PMID: 35336520 PMCID: PMC8953998 DOI: 10.3390/s22062351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 03/09/2022] [Accepted: 03/15/2022] [Indexed: 01/27/2023]
Abstract
Music is an invaluable tool to improve affective valence during exercise, with the potential contribution of a mechanism called rhythmic entrainment. However, several methodological limitations impair our current understanding of the effect of music on relevant psychophysiological responses to exercise, including breathing variables. This study presents conceptual, methodological, and operational insight favoring the investigation of the effect of music on breathing during exercise. Three tools were developed for the quantification of the presence, degree, and magnitude of music-locomotor, locomotor-breathing, and music-breathing entrainment. The occurrence of entrainment was assessed during 30 min of moderate cycling exercise performed either when listening to music or not, and was complemented by the recording of relevant psychophysiological and mechanical variables. Respiratory frequency and expiratory time were among the physiological variables that were affected to a greater extent by music during exercise, and a significant (p < 0.05) music-breathing entrainment was found in all 12 participants. These findings suggest the importance of evaluating the effect of music on breathing responses to exercise, with potential implications for exercise prescription and adherence, and for the development of wearable devices simultaneously measuring music, locomotor, and breathing signals.
Collapse
|
research-article |
3 |
|
16
|
Vainio O, Palmu L. Cardiovascular and respiratory effects of medetomidine in dogs and influence of anticholinergics. Acta Vet Scand 1989; 30:401-8. [PMID: 2640776 PMCID: PMC8142219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
A total of 10 laboratory beagles was used to determine the cardiovascular and respiratory effects of medetomidine. The effects of atropine sulphate and glycopyrrolate on heart rate were also observed. Xylazine was included as a positive control. Medetomidine induced initial hypertension followed by a longer lasting hypotensive period. Evident bradycardia with second degree atrioventricular blocks and decrease in respiratory frequency was observed. Atropine sulphate and glycopyrrolate transiently abolished the bradycardic effect of medetomidine. Xylazine exhibited a similar cardiovascular and respiratory pattern to medetomidine.
Collapse
|
research-article |
36 |
|
17
|
Rogers B, Schaffarczyk M, Gronwald T. Improved Estimation of Exercise Intensity Thresholds by Combining Dual Non-Invasive Biomarker Concepts: Correlation Properties of Heart Rate Variability and Respiratory Frequency. SENSORS (BASEL, SWITZERLAND) 2023; 23:1973. [PMID: 36850571 PMCID: PMC9967516 DOI: 10.3390/s23041973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 02/06/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Identifying exercise intensity boundaries has been shown to be important during endurance training for performance enhancement and rehabilitation. Unfortunately, even though surrogate markers show promise when assessed on a group level, substantial deviation from gold standards can be present in each individual. The aim of this study was to evaluate whether combining two surrogate intensity markers improved this agreement. Electrocardiogram (ECG) and gas exchange data were obtained from 21 participants who performed an incremental cycling ramp to exhaustion and evaluated for first (VT1) and second (VT2) ventilatory thresholds, heart rate (HR) variability (HRV), and ECG derived respiratory frequency (EDR). HRV thresholds (HRVT) were based on the non-linear index a1 of a Detrended Fluctuation Analysis (DFA a1) and EDR thresholds (EDRT) upon the second derivative of the sixth-order polynomial of EDR over time. The average of HRVT and EDRT HR was set as the combined threshold (Combo). Mean VT1 was reached at a HR of 141 ± 15, HRVT1 at 152 ± 14 (p < 0.001), EDRT1 at 133 ± 12 (p < 0.001), and Combo1 at 140 ± 13 (p = 0.36) bpm with Pearson's r of 0.83, 0.78, and 0.84, respectively, for comparisons to VT1. A Bland-Altman analysis showed mean biases of 8.3 ± 7.9, -8.3 ± 9.5, and -1.7 ± 8.3 bpm, respectively. A mean VT2 was reached at a HR of 165 ± 13, HRVT2 at 167 ± 10 (p = 0.89), EDRT2 at 164 ± 14 (p = 0.36), and Combo2 at 164 ± 13 (p = 0.59) bpm with Pearson's r of 0.58, 0.95, and 0.94, respectively, for comparisons to VT2. A Bland-Altman analysis showed mean biases of -0.3 ± 8.9, -1.0 ± 4.6, and -0.6 ± 4.6 bpm, respectively. Both the DFA a1 and EDR intensity thresholds based on HR taken individually had moderate agreement to targets derived through gas exchange measurements. By combining both non-invasive approaches, there was improved correlation, reduced bias, and limits of agreement to the respective corresponding HRs at VT1 and VT2.
Collapse
|
research-article |
2 |
|
18
|
Nicolò A, Girardi M, Bazzucchi I, Sacchetti M, Felici F. Ventilation and perceived exertion are sensitive to changes in exercise tolerance: arm+leg cycling vs. leg cycling. Front Physiol 2023; 14:1226421. [PMID: 37593234 PMCID: PMC10427861 DOI: 10.3389/fphys.2023.1226421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Accepted: 07/20/2023] [Indexed: 08/19/2023] Open
Abstract
Purpose: Growing evidence suggests that respiratory frequency (f R) is a marker of physical effort and a variable sensitive to changes in exercise tolerance. The comparison between arm+leg cycling (Arm+leg) and leg cycling (Leg) has the potential to further test this notion because a greater exercise tolerance is expected in the Arm+leg modality. We systematically compared Arm+leg vs. Leg using different performance tests. Methods: Twelve males underwent six performance tests in separate, randomized visits. Three tests were performed in each of the two exercise modalities, i.e. an incremental test and two time-to-exhaustion (TTE) tests performed at 90% or 75% of the peak power output reached in the Leg incremental test (PPOLeg). Exercise tolerance, perceived exertion, and cardiorespiratory variables were recorded during all the tests. Results: A greater exercise tolerance (p < 0.001) was found for Arm+leg in the incremental test (337 ± 32 W vs. 292 ± 28 W), in the TTE test at 90% of PPOLeg (638 ± 154 s vs. 307 ± 67 s), and in the TTE test at 75% of PPOLeg (1,675 ± 525 s vs. 880 ± 363 s). Unlike V ˙ O2 and heart rate, both f R and minute ventilation were lower (p < 0.003) at isotime in all the Arm+leg tests vs. Leg tests. Furthermore, a lower perceived exertion was observed in the Arm+leg tests, especially during the TTE tests (p < 0.001). Conclusion: Minute ventilation, f R and perceived exertion are sensitive to the improvements in exercise tolerance observed when comparing Arm+leg vs. Leg, unlike V ˙ O2 and heart rate.
Collapse
|
research-article |
2 |
|
19
|
Nicolò A, Gruet M, Sacchetti M. Editorial: Breathing in sport and exercise: physiology, pathophysiology and applications. Front Physiol 2023; 14:1347806. [PMID: 38192742 PMCID: PMC10773579 DOI: 10.3389/fphys.2023.1347806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 12/05/2023] [Indexed: 01/10/2024] Open
|
Editorial |
2 |
|
20
|
Romano C, Nicolò A, Innocenti L, Sacchetti M, Schena E, Massaroni C. Design and Testing of a Smart Facemask for Respiratory Monitoring during Cycling Exercise. BIOSENSORS 2023; 13:369. [PMID: 36979581 PMCID: PMC10046471 DOI: 10.3390/bios13030369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 03/03/2023] [Accepted: 03/06/2023] [Indexed: 06/18/2023]
Abstract
Given the importance of respiratory frequency (fR) as a valid marker of physical effort, there is a growing interest in developing wearable devices measuring fR in applied exercise settings. Biosensors measuring chest wall movements are attracting attention as they can be integrated into textiles, but their susceptibility to motion artefacts may limit their use in some sporting activities. Hence, there is a need to exploit sensors with signals minimally affected by motion artefacts. We present the design and testing of a smart facemask embedding a temperature biosensor for fR monitoring during cycling exercise. After laboratory bench tests, the proposed solution was tested on cyclists during a ramp incremental frequency test (RIFT) and high-intensity interval training (HIIT), both indoors and outdoors. A reference flowmeter was used to validate the fR extracted from the temperature respiratory signal. The smart facemask showed good performance, both at a breath-by-breath level (MAPE = 2.56% and 1.64% during RIFT and HIIT, respectively) and on 30 s average fR values (MAPE = 0.37% and 0.23% during RIFT and HIIT, respectively). Both accuracy and precision (MOD ± LOAs) were generally superior to those of other devices validated during exercise. These findings have important implications for exercise testing and management in different populations.
Collapse
|
research-article |
2 |
|