Jordan RW, Kelly CP, Pap G, Joudet T, Nyffeler RW, Reuther F, Irlenbusch U. Mid-term results of a stemless ceramic on polyethylene shoulder prosthesis - A prospective multicentre study.
Shoulder Elbow 2021;
13:67-77. [PMID:
33717220 PMCID:
PMC7905519 DOI:
10.1177/1758573219866431]
[Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 06/09/2019] [Accepted: 07/05/2019] [Indexed: 11/17/2022]
Abstract
INTRODUCTION
Early reports of stemless shoulder arthroplasty have shown promising clinical and radiological outcomes. The purpose of this study was to report on the mid-term results of an implant that utilises a ceramic humeral head.
METHODS
A prospective, consecutive, multicentre study of stemless shoulder prosthesis with a minimum of four years of follow-up was conducted between August 2009 and May 2012. The adjusted Constant-Murley Score (CMS), revision rate and presence of radiolucent lines were recorded at intervals.
RESULTS
A total of 207 patients were eligible for study inclusion; 62.8% were female and mean age was 64.8 years (range 30-86). Mean follow-up was 70.7 months (range 48-100), 73% underwent TSA and 27% hemiarthroplasty. The mean CMS improvement was 42.6 (p < 0.0001) at 48 months. Radiolucencies were present in 2.7% of humeral zones and 14% of glenoid zones at 48-month follow-up. The revision rate was 6.3% with rotator cuff failure (2.9%) the most common indication.
CONCLUSIONS
Mid-term results demonstrate that the studied stemless implant with a ceramic humeral head had clinical and radiological outcomes that are comparable to other reported studies.