1
|
Gueriau P, Réguer S, Leclercq N, Cupello C, Brito PM, Jauvion C, Morel S, Charbonnier S, Thiaudière D, Mocuta C. Visualizing mineralization processes and fossil anatomy using synchronous synchrotron X-ray fluorescence and X-ray diffraction mapping. J R Soc Interface 2020; 17:20200216. [PMID: 32842887 DOI: 10.1098/rsif.2020.0216] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Fossils, including those that occasionally preserve decay-prone soft tissues, are mostly made of minerals. Accessing their chemical composition provides unique insight into their past biology and/or the mechanisms by which they preserve, leading to a series of developments in chemical and elemental imaging. However, the mineral composition of fossils, particularly where soft tissues are preserved, is often only inferred indirectly from elemental data, while X-ray diffraction that specifically provides phase identification received little attention. Here, we show the use of synchrotron radiation to generate not only X-ray fluorescence elemental maps of a fossil, but also mineralogical maps in transmission geometry using a two-dimensional area detector placed behind the fossil. This innovative approach was applied to millimetre-thick cross-sections prepared through three-dimensionally preserved fossils, as well as to compressed fossils. It identifies and maps mineral phases and their distribution at the microscale over centimetre-sized areas, benefitting from the elemental information collected synchronously, and further informs on texture (preferential orientation), crystallite size and local strain. Probing such crystallographic information is instrumental in defining mineralization sequences, reconstructing the fossilization environment and constraining preservation biases. Similarly, this approach could potentially provide new knowledge on other (bio)mineralization processes in environmental sciences. We also illustrate that mineralogical contrasts between fossil tissues and/or the encasing sedimentary matrix can be used to visualize hidden anatomies in fossils.
Collapse
|
|
5 |
10 |
2
|
Brooks J, Everett J, Lermyte F, Tjhin VT, Banerjee S, O'Connor PB, Morris CM, Sadler PJ, Telling ND, Collingwood JF. Label-Free Nanoimaging of Neuromelanin in the Brain by Soft X-ray Spectromicroscopy. Angew Chem Int Ed Engl 2020; 59:11984-11991. [PMID: 32227670 PMCID: PMC7383895 DOI: 10.1002/anie.202000239] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Revised: 03/10/2020] [Indexed: 12/22/2022]
Abstract
A hallmark of Parkinson's disease is the death of neuromelanin-pigmented neurons, but the role of neuromelanin is unclear. The in situ characterization of neuromelanin remains dependent on detectable pigmentation, rather than direct quantification of neuromelanin. We show that direct, label-free nanoscale visualization of neuromelanin and associated metal ions in human brain tissue can be achieved using synchrotron scanning transmission x-ray microscopy (STXM), through a characteristic feature in the neuromelanin x-ray absorption spectrum at 287.4 eV that is also present in iron-free and iron-laden synthetic neuromelanin. This is confirmed in consecutive brain sections by correlating STXM neuromelanin imaging with silver nitrate-stained neuromelanin. Analysis suggests that the 1s-σ* (C-S) transition in benzothiazine groups accounts for this feature. This method illustrates the wider potential of STXM as a label-free spectromicroscopy technique applicable to both organic and inorganic materials.
Collapse
|
research-article |
5 |
10 |
3
|
Canullo L, Giuliani A, Furlani M, Menini M, Piattelli A, Iezzi G. Influence of abutment macro- and micro-geometry on morphologic and morphometric features of peri-implant connective tissue. Clin Oral Implants Res 2023; 34:920-933. [PMID: 37345230 DOI: 10.1111/clr.14118] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 05/10/2023] [Accepted: 06/10/2023] [Indexed: 06/23/2023]
Abstract
OBJECTIVES The aim of the present human observational study is to provide morphologic and morphometric analysis of peri-implant connective tissue next to abutments with divergent or convergent macro-geometry and different surface micro-characteristics. MATERIALS AND METHODS Thirty patients were rehabilitated with single implants in the posterior area and one out of three different healing abutments with a one-stage technique: machined divergent abutment (DIV-MAC), machined convergent abutment (CONV-MAC) or convergent abutment with ultrathin threaded surface (CONV-UTM). At 3 months postimplant insertion, peri-implant soft tissue was harvested; the following outcomes were investigated: histomorphometry (vertical width of connective and epithelial components) as detected by histology and polarized light; and connective tissue vertical width and 3D organization as detected by synchrotron-based high-resolution phase-contrast-based tomography (PhC-μCT). RESULTS Significant differences in connective tissue vertical dimension (aJE-AM) were found between DIV-MAC and both CONV-MAC and CONV-UTM, both by histology and PhC-μCT, with significantly higher values for the last two groups. Moreover, 2D histological analysis did not find significant differences in the junctional epithelium vertical dimension (PM-aJE). Importantly, PhC-μCT analysis revealed, at 3D level, significant greater amount and density of collagen bundles for CONV-UTM compared with the other two groups. CONCLUSIONS Convergent abutment profiles, regardless of their surface micro-geometry, seem to favor axial development of peri-implant connective tissue. Moreover, ultrathin threaded surfaces seem associated with denser and greater connective tissue organization, which might improve peri-implant soft tissue seal.
Collapse
|
Observational Study |
2 |
6 |
4
|
Alhosani A, Scanziani A, Lin Q, Selem A, Pan Z, Blunt MJ, Bijeljic B. Three-phase flow displacement dynamics and Haines jumps in a hydrophobic porous medium. Proc Math Phys Eng Sci 2021; 476:20200671. [PMID: 33402876 PMCID: PMC7776970 DOI: 10.1098/rspa.2020.0671] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Accepted: 11/19/2020] [Indexed: 11/12/2022] Open
Abstract
We use synchrotron X-ray micro-tomography to investigate the displacement dynamics during three-phase—oil, water and gas—flow in a hydrophobic porous medium. We observe a distinct gas invasion pattern, where gas progresses through the pore space in the form of disconnected clusters mediated by double and multiple displacement events. Gas advances in a process we name three-phase Haines jumps, during which gas re-arranges its configuration in the pore space, retracting from some regions to enable the rapid filling of multiple pores. The gas retraction leads to a permanent disconnection of gas ganglia, which do not reconnect as gas injection proceeds. We observe, in situ, the direct displacement of oil and water by gas as well as gas–oil–water double displacement. The use of local in situ measurements and an energy balance approach to determine fluid–fluid contact angles alongside the quantification of capillary pressures and pore occupancy indicate that the wettability order is oil–gas–water from most to least wetting. Furthermore, quantifying the evolution of Minkowski functionals implied well-connected oil and water, while the gas connectivity decreased as gas was broken up into discrete clusters during injection. This work can be used to design CO2 storage, improved oil recovery and microfluidic devices.
Collapse
|
|
4 |
4 |
5
|
Agrawal AK, Singh B, Kashyap YS, Shukla M, Manjunath BS, Gadkari SC. Gamma-irradiation-induced micro-structural variations in flame-retardant polyurethane foam using synchrotron X-ray micro-tomography. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:1797-1807. [PMID: 31490172 DOI: 10.1107/s1600577519009792] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Accepted: 07/08/2019] [Indexed: 06/10/2023]
Abstract
Flame-retardant polyurethane foams are potential packing materials for the transport casks of highly active nuclear materials for shock absorption and insulation purposes. Exposure of high doses of gamma radiation causes cross-linking and chain sectioning of macromolecules in this polymer foam, which leads to reorganization of their cellular microstructure and thereby variations in physico-mechanical properties. In this study, in-house-developed flame-retardant rigid polyurethane foam samples were exposed to gamma irradiation doses in the 0-20 kGy range and synchrotron radiation X-ray micro-computed tomography (SR-µCT) imaging was employed for the analysis of radiation-induced morphological variations in their cellular microstructure. Qualitative and quantitative analysis of SR-µCT images has revealed significant variations in the average cell size, shape, wall thickness, orientations and spatial anisotropy of the cellular microstructure in polyurethane foam.
Collapse
|
|
6 |
3 |
6
|
Cohen SX, Webb SM, Gueriau P, Curis E, Bertrand L. Robust framework and software implementation for fast speciation mapping. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:1049-1058. [PMID: 33566015 DOI: 10.1107/s1600577520005822] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Accepted: 04/27/2020] [Indexed: 06/12/2023]
Abstract
One of the greatest benefits of synchrotron radiation is the ability to perform chemical speciation analysis through X-ray absorption spectroscopies (XAS). XAS imaging of large sample areas can be performed with either full-field or raster-scanning modalities. A common practice to reduce acquisition time while decreasing dose and/or increasing spatial resolution is to compare X-ray fluorescence images collected at a few diagnostic energies. Several authors have used different multivariate data processing strategies to establish speciation maps. In this manuscript, the theoretical aspects and assumptions that are often made in the analysis of these datasets are focused on. A robust framework is developed to perform speciation mapping in large bulk samples at high spatial resolution by comparison with known references. Two fully operational software implementations are provided: a user-friendly implementation within the MicroAnalysis Toolkit software, and a dedicated script developed under the R environment. The procedure is exemplified through the study of a cross section of a typical fossil specimen. The algorithm provides accurate speciation and concentration mapping while decreasing the data collection time by typically two or three orders of magnitude compared with the collection of whole spectra at each pixel. Whereas acquisition of spectral datacubes on large areas leads to very high irradiation times and doses, which can considerably lengthen experiments and generate significant alteration of radiation-sensitive materials, this sparse excitation energy procedure brings the total irradiation dose greatly below radiation damage thresholds identified in previous studies. This approach is particularly adapted to the chemical study of heterogeneous radiation-sensitive samples encountered in environmental, material, and life sciences.
Collapse
|
|
5 |
3 |
7
|
Carmona A, Chen S, Domart F, Choquet D, Ortega R. Imaging the structural organization of chemical elements in growth cones of developing hippocampal neurons. Metallomics 2021; 14:6462920. [PMID: 34910190 DOI: 10.1093/mtomcs/mfab073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 12/06/2021] [Indexed: 11/14/2022]
Abstract
During neurodevelopment, neurons form growth cones, F-actin rich extensions located at the distal end of the neurites. Growth cones allow dendrites and axons to build synaptic connections through a process of neurite guidance whose mechanisms have not been fully elucidated. Calcium is an important element in this process by inducing F-actin reorganization. We hypothesized that other biologically active elements might be involved in the growth cone-mediated neurite guidance mechanisms. We performed super resolution and confocal microscopy of F-actin, followed by synchrotron X-ray fluorescence microscopy of phosphorous, sulfur, chlorine, potassium, calcium, iron and zinc on growth cones from primary rat hippocampal neurons. We identified two main patterns of element organization. First, active growth cones presenting an asymmetric distribution of Ca co-localized with the cytoskeleton protein F-actin. In active growth cones, we found that the distributions of P, S, Cl, K and Zn are correlated with Ca. This correlation is lost in the second pattern, quiescent growth cones, exhibiting a spread elemental distribution. These results suggest that Ca is not the only element required in the F-actin rich active regions of growth cones. In addition, highly concentrated Fe spots of sub-micrometer size were observed in calcium-rich areas of active growth cones. These results reveal the need for biological active elements in growth cones during neural development and may help explain why early life deficiencies of elements, such as Fe or Zn, induce learning and memory deficits in children.
Collapse
|
|
4 |
1 |
8
|
Montgomery JE, Wesolowski MJ, Wolkowski B, Chibbar R, Snead ECR, Singh J, Pettitt M, Malhi PS, Barboza T, Adams G. Demonstration of synchrotron x-ray phase contrast imaging computed tomography of infiltrative transitional cell carcinoma of the prostatic urethra in a dog. J Med Imaging (Bellingham) 2016; 3:015504. [PMID: 27014719 DOI: 10.1117/1.jmi.3.1.015504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2015] [Accepted: 02/25/2016] [Indexed: 11/14/2022] Open
Abstract
Prostatic urethral transitional cell carcinoma with prostatic invasion in a dog was imaged with abdominal radiography and abdominal ultrasonography antemortem. Synchrotron in-line x-ray phase contrast imaging computed tomography (XPCI-CT) was performed on the prostate ex vivo at the Canadian Light Source Synchrotron and compared to histology. XPCI-CT imaging provides greater soft tissue contrast than conventional absorption-based x-ray imaging modalities, permitting visualization of regions of inflammatory cell infiltration, differentiation of invasive versus noninvasive tumor regions, and areas of necrosis and mineralization. This represents the first report of XPCI-CT images of an invasive prostatic urothelial neoplasm in a dog.
Collapse
|
|
9 |
|
9
|
Pierantoni M, Hammerman M, Silva Barreto I, Larsson D, Notermans T, Bodey AJ, Eliasson P, Isaksson H. Spatiotemporal and microstructural characterization of heterotopic ossification in healing rat Achilles tendons. FASEB J 2023; 37. [PMID: 37219456 DOI: 10.1096/fj.202201018rrr] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 04/18/2023] [Accepted: 05/05/2023] [Indexed: 05/24/2023]
Abstract
Achilles tendon rupture is a common debilitating medical condition. The healing process is slow and can be affected by heterotopic ossification (HO), which occurs when pathologic bone-like tissue is deposited instead of the soft collagenous tendon tissue. Little is known about the temporal and spatial progression of HO during Achilles tendon healing. In this study we characterize HO deposition, microstructure, and location at different stages of healing in a rat model. We use phase contrast-enhanced synchrotron microtomography, a state-of-the-art technique that allows 3D imaging at high-resolution of soft biological tissues without invasive or time-consuming sample preparation. The results increase our understanding of HO deposition, from the early inflammatory phase of tendon healing, by showing that the deposition is initiated as early as one week after injury in the distal stump and mostly growing on preinjury HO deposits. Later, more deposits form first in the stumps and then all over the tendon callus, merging into large, calcified structures, which occupy up to 10% of the tendon volume. The HOs were characterized by a looser connective trabecular-like structure and a proteoglycan-rich matrix containing chondrocyte-like cells with lacunae. The study shows the potential of 3D imaging at high-resolution by phase-contrast tomography to better understand ossification in healing tendons.
Collapse
|
Review |
2 |
|
10
|
Alizadeh Sardroud H, Rosa GDS, Dust W, Cham TC, Roy G, Bater S, Chicoine A, Honaramooz A, Chen X, Eames BF. Comparison study on hyaline cartilage versus fibrocartilage formation in a pig model by using 3D-bioprinted hydrogel and hybrid constructs. Biofabrication 2024; 17. [PMID: 39423833 DOI: 10.1088/1758-5090/ad88a6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Accepted: 10/18/2024] [Indexed: 10/21/2024]
Abstract
Cartilage tissue engineering (CTE) with the help of engineered constructs has shown promise for the regeneration of hyaline cartilage, where fibrocartilage may also be formed due to the biomechanical loading resulting from the host weight and movement. Previous studies have primarily reported on hyaline cartilage formationin vitroand/or in small animals, while leaving the fibrocartilage formation undiscovered. In this paper, we, at the first time, present a comparison study on hyaline cartilage versus fibrocartilage formation in a large animal model of pig by using two constructs (namely hydrogel and hybrid ones) engineered by means of three-dimensional (3D) bioprinting. Both hydrogel and hybrid constructs were printed from the bioink of alginate (2.5%) and ATDC5 cells (chondrogenic cells at a cell density of 5 × 106cells ml-1), with the difference in that in the hybrid construct, there was a polycaprolactone (PCL) strand printed between every two bioink strands, which were strategically designed to shield the force imposed on the cells within the bioink strands. Both hydrogel and hybrid constructs were implanted into the chondral defects created in the articular cartilage of weight-bearing portions of pig stifle joints; the cartilage formation was examined at one- and three-months post-implantation, respectively, by means of Safranin O, Trichrome, immunofluorescent staining, and synchrotron radiation-based (SR) inline phase contrast imaging microcomputed tomography (inline-PCI-CT). Glycosaminoglycan (GAG) and collagen type II (Col II) secretion were used to evaluate the hyaline cartilage formation, while collagen type I (Col I) was used to indicate fibrocartilage given that Col I is low in hyaline cartilage but high in fibrocartilage. Our results revealed that cartilage formation was enhanced over time in both hydrogel and hybrid constructs; particularly, the hydrogel construct exhibited more cartilage formation at both one- and three-months post-implantation, while hybrid constructs tended to have less fibrocartilage formed in a long time period. Also, the result from the inline-PCI-CT revealed that the inline-PCI-CT was able to provide not only the information seen in other histology images, but also high-resolution details of biomaterials and regenerating cartilage. This would represent a significant advance toward the non-invasive assessment of cartilage formation regeneration within large animal models and eventually in human patients.
Collapse
|
Comparative Study |
1 |
|
11
|
van der Have O, Mead TJ, Westöö C, Peruzzi N, Mutgan AC, Norvik C, Bech M, Struglics A, Hoetzenecker K, Brunnström H, Westergren‐Thorsson G, Kwapiszewska G, Apte SS, Tran‐Lundmark K. Aggrecan accumulates at sites of increased pulmonary arterial pressure in idiopathic pulmonary arterial hypertension. Pulm Circ 2023; 13:e12200. [PMID: 36824691 PMCID: PMC9941846 DOI: 10.1002/pul2.12200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 02/01/2023] [Accepted: 02/03/2023] [Indexed: 02/11/2023] Open
Abstract
Expansion of extracellular matrix occurs in all stages of pulmonary angiopathy associated with pulmonary arterial hypertension (PAH). In systemic arteries, dysregulation and accumulation of the large chondroitin-sulfate proteoglycan aggrecan is associated with swelling and disruption of vessel wall homeostasis. Whether aggrecan is present in pulmonary arteries, and its potential roles in PAH, has not been thoroughly investigated. Here, lung tissue from 11 patients with idiopathic PAH was imaged using synchrotron radiation phase-contrast microcomputed tomography (TOMCAT beamline, Swiss Light Source). Immunohistochemistry for aggrecan core protein in subsequently sectioned lung tissue demonstrated accumulation in PAH compared with failed donor lung controls. RNAscope in situ hybridization indicated ACAN expression in vascular endothelium and smooth muscle cells. Based on qualitative histological analysis, aggrecan localizes to cellular, rather than fibrotic or collagenous, lesions. Interestingly, ADAMTS15, a potential aggrecanase, was upregulated in pulmonary arteries in PAH. Aligning traditional histological analysis with three-dimensional renderings of pulmonary arteries from synchrotron imaging identified aggrecan in lumen-reducing lesions containing loose, cell-rich connective tissue, at sites of intrapulmonary bronchopulmonary shunting, and at sites of presumed elevated pulmonary blood pressure. Our findings suggest that ACAN expression may be an early response to injury in pulmonary angiopathy and supports recent work showing that dysregulation of aggrecan turnover is a hallmark of arterial adaptations to altered hemodynamics. Whether cause or effect, aggrecan and aggrecanase regulation in PAH are potential therapeutic targets.
Collapse
|
research-article |
2 |
|
12
|
Diez M, Zabler S. Determining the optimal choice of attenuation filters and propagation distance for polychromatic phase-contrast micro-computed tomography of a multi-material electromotor using synchrotron radiation. JOURNAL OF SYNCHROTRON RADIATION 2025; 32:731-742. [PMID: 40266726 PMCID: PMC12067323 DOI: 10.1107/s1600577525002814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2024] [Accepted: 03/27/2025] [Indexed: 04/25/2025]
Abstract
Optimizing phase-contrast micro-computed tomography (µCT) for a given object is not trivial if the radiation is polychromatic and the object multi-material. This study demonstrates how an optimal combination of propagation distance and mean energy (set by attenuation filters) may be derived for such an object (an electromotor scanned on beamline BM18 at ESRF in Grenoble, France). In addition to appropriate image quality metrics, it is mandatory to define a task. In that respect, raising Emean from 100 keV to 164 keV mitigates beam hardening by metal parts, yet raising Emean further to 230 keV deteriorates CNR2 (where CNR is contrast-to-noise ratio) due to higher image noise. Propagation distances between d = 2 m and 25.3 m are evaluated crosswise with energy. While longer propagation distances generally yield higher CNR2, shorter distances appear favorable when discerning plastic near metal parts. SNR2 (where SNR is signal-to-noise ratio) power spectra and modulation transfer (MTF) are evaluated independently from two-dimensional projections supporting volume image analysis for which image sharpness depends strongly on the digital filters (Paganin and Wiener) which are applied along with filtered back-projection. In summary, optimizing synchrotron µCT scans remains a very complex task which differs from object to object. A physically accurate model of the complete imaging process may not only allow for optimization by simulation but also ideally improve CT image reconstruction in the near future.
Collapse
|
research-article |
1 |
|
13
|
Jones MP, Storm M, York APE, Hyde TI, Hatton GD, Greenaway AG, Haigh SJ, Eastwood DS. 4D In-Situ Microscopy of Aerosol Filtration in a Wall Flow Filter. MATERIALS 2020; 13:ma13245676. [PMID: 33322695 PMCID: PMC7763601 DOI: 10.3390/ma13245676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 12/09/2020] [Accepted: 12/10/2020] [Indexed: 12/04/2022]
Abstract
The transient nature of the internal pore structure of particulate wall flow filters, caused by the continuous deposition of particulate matter, makes studying their flow and filtration characteristics challenging. In this article we present a new methodology and first experimental demonstration of time resolved in-situ synchrotron micro X-ray computed tomography (micro-CT) to study aerosol filtration. We directly imaged in 4D (3D plus time) pore scale deposits of TiO2 nanoparticles (nominal mean primary diameter of 25 nm) with a pixel resolution of 1.6 μm. We obtained 3D tomograms at a rate of ∼1 per minute. The combined spatial and temporal resolution allows us to observe pore blocking and filling phenomena as they occur in the filter’s pore space. We quantified the reduction in filter porosity over time, from an initial porosity of 0.60 to a final porosity of 0.56 after 20 min. Furthermore, the penetration depth of particulate deposits and filtration rate was quantified. This novel image-based method offers valuable and statistically relevant insights into how the pore structure and function evolves during particulate filtration. Our data set will allow validation of simulations of automotive wall flow filters. Evolutions of this experimental design have potential for the study of a wide range of dry aerosol filters and could be directly applied to catalysed automotive wall flow filters.
Collapse
|
|
5 |
|
14
|
Bernardino G, Calvet-Mirabent À, Dejea H, Guasch E, Bonnin A, Garcia-Canadilla P. The use of ethanol as contrast enhancer in synchrotron X-ray phase-contrast imaging leads to heterogeneous myocardial tissue shrinkage: a case report. JOURNAL OF SYNCHROTRON RADIATION 2025; 32:200-209. [PMID: 39689036 PMCID: PMC11708853 DOI: 10.1107/s1600577524010221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Accepted: 10/18/2024] [Indexed: 12/19/2024]
Abstract
One of the main limitations of conventional absorption-based X-ray micro-computed tomography imaging of biological samples is the low inherent X-ray contrast of soft tissue. To overcome this limitation, the use of ethanol as contrast agent has been proposed to enhance image contrast of soft tissues through dehydration. Some authors have shown that ethanol shrinks and hardens the tissue too much, also causing small tissue ruptures due to fast dehydration. However, the local tissue deformation occurring as a consequence of tissue dehydration and whether tissue shrinkage can modify myocardial architecture has not been quantified yet. The aim of this paper is to quantify the local myocardial tissue deformation due to ethanol dehydration based on 3D non-rigid registration and perform a detailed characterization of its myocardial tissue organization, before and after ethanol dehydration. A rat adult heart was imaged with synchrotron-radiation-based X-ray phase contrast imaging (X-PCI) three times: before, 9 h after and 342 h after ethanol immersion. The total volume shrinkage as well as changes in the left ventricular myocardial thickness were computed. Then, to determine local deformation of the heart caused by ethanol dehydration, the related 3D tomographic datasets were registered by means of a non-rigid registration algorithm. Finally, changes on the orientation and organization of myocytes were assessed. Our results show that the use of ethanol in synchrotron X-PCI can improve image contrast, but the tissue shrinkage is not homogeneous thus changing the local myocardial organization.
Collapse
|
research-article |
1 |
|
15
|
Moussa MS, de Vet T, Lebcir N, Zaslansky P, Chalifour LE, Willie BM, Komarova SV. Botulinum toxin (a) -induced bone loss is associated with increased blood velocity and reduced vascular bone porosity. J Bone Miner Res 2025:zjaf057. [PMID: 40272396 DOI: 10.1093/jbmr/zjaf057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2024] [Revised: 04/01/2025] [Accepted: 04/12/2025] [Indexed: 04/25/2025]
Abstract
Disuse-induced bone loss is a common consequence of spaceflight and prolonged bed rest. Intraosseous blood vessel volume and number are decreased in rodents after sciatic nerve resection, and femoral and tibial perfusion and blood flow to the femoral shaft and marrow are reduced after hindlimb unloading. However, it is unclear if alterations in the flow of blood contribute to botulinum toxin (BTX)-induced bone loss. The objective of this study was to assess patterns of tibial bone loss and alterations in blood flow in murine hindlimbs following BTX injection. We hypothesize that flow of blood to the affected hindlimb will diminish along with bone mass and structure. Skeletally mature C57Bl/6 J female were injected with BTX (n = 15) or vehicle (n = 14). Paralysis was confirmed using digit abduction, wire hang tests, and activity analysis. In vivo microCT and ex vivo synchrotron tomography were used to assess bone mass, microstructure, (re)modeling, as well as vascular and lacunar porosity. Blood flow in the hindlimbs and cardiac structure/function was monitored by echocardiography. After three weeks, BTX-injected tibiae had 16% lower cortical thickness and 66% lower trabecular bone volume fraction compared to baseline. MicroCT-based timelapse morphometry showed bone loss was predominantly at endocortical surfaces. Bone loss in the contralateral limb was coincident with reduced rearing capability of BTX-injected mice compared to vehicle controls. Bony vascular canal thickness and surface area were reduced, but there was no change in lacunar properties due to BTX. In vivo ultrasound demonstrated increased velocity time integral for blood flow due to BTX injection in femoral and popliteal but not in saphenous arteries. Thus, BTX led to significant bone loss in hindlimbs, while increasing blood velocity in the femoral popliteal arteries and decreasing vascular porosity. The vascular response to BTX differs from what has been observed in other hindlimb unloading models.
Collapse
|
|
1 |
|