1
|
Indocyanine green: A novel marker for assessment of graft quality during ex situ normothermic machine perfusion of human livers. Artif Organs 2024; 48:472-483. [PMID: 38132848 DOI: 10.1111/aor.14696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Revised: 11/27/2023] [Accepted: 12/06/2023] [Indexed: 12/23/2023]
Abstract
BACKGROUND Ex situ machine perfusion facilitates the assessment of livers prior to transplantation. However, currently available markers of liver function poorly predict long-term graft function. Indocyanine green (ICG) is a liver-specific dye which, although common in vivo, has never been comprehensively evaluated for the assessment of graft quality during ex situ machine perfusion. This study aimed to assess the utility of ICG in the ex situ setting. METHODS Using a customized long-term perfusion system, human livers that were not suitable for transplantation were perfused using a red cell-based perfusate. ICG was delivered into the perfusate on days 0, 1, and 4 to assess ICG clearance (spectrophotometric absorbance at 805 nm) and ICG fluorescence (near-infrared camera). RESULTS Sixteen partial livers were perfused for a median duration of 172 h (7.2 days). On day 0, the median ICG perfusate disappearance rate (PDR) was 7.5%/min and the median ICG retention at 15 min was 9.9%. Grafts that survived ≥7 days had a significantly higher median ICG PDR on day 0 (14.5%/min vs. 6.5%/min, p = 0.005) but not on days 1 or 4. ICG perfusion demonstrated that long-surviving grafts had a significantly lower median red-value (89.8 vs. 118.6, p = 0.011) and a significantly lower median blue-value (12.9 vs. 22.6, p = 0.045) than short-surviving grafts. CONCLUSION ICG is a novel marker for the assessment of liver function during ex situ normothermic machine perfusion. ICG PDR and quantitative ICG perfusion can distinguish between long- and short-surviving grafts and demonstrate the utility of ICG in the assessment of graft quality prior to transplant.
Collapse
|
2
|
Expanding the Horizons of Pre-Transplant Renal Vascular Assessment Using Ex Vivo Perfusion. Curr Issues Mol Biol 2023; 45:5437-5459. [PMID: 37504261 PMCID: PMC10378498 DOI: 10.3390/cimb45070345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 06/21/2023] [Accepted: 06/27/2023] [Indexed: 07/29/2023] Open
Abstract
Recently, immense efforts have focused on improving the preservation of (sub)optimal donor organs by means of ex vivo perfusion, which enables the opportunity for organ reconditioning and viability assessment. However, there is still no biomarker that correlates with renal viability. Therefore, it is essential to explore new techniques for pre-transplant assessment of organ quality to guarantee successful long-term transplantation outcomes. The renal vascular compartment has received little attention in machine perfusion studies. In vivo, proper renal vascular and endothelial function is essential for maintaining homeostasis and long-term graft survival. In an ex vivo setting, little is known about vascular viability and its implications for an organ's suitability for transplant. Seeing that endothelial damage is the first step in a cascade of disruptions and maintaining homeostasis is crucial for positive post-transplant outcomes, further research is key to clarifying the (patho)physiology of the renal vasculature during machine perfusion. In this review, we aim to summarize key aspects of renal vascular physiology, describe the role of the renal vasculature in pathophysiological settings, and explain how ex vivo perfusion plays a role in either unveiling or targeting such processes. Additionally, we discuss potentially new vascular assessment tools during ex vivo renal perfusion.
Collapse
|
3
|
A Pilot Study to Detect Viable Salmonella spp. in Diarrheal Stool Using Viability Real-Time PCR as a Culture-Independent Diagnostic Tool in a Clinical Setting. Int J Mol Sci 2023; 24:9979. [PMID: 37373127 DOI: 10.3390/ijms24129979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 06/08/2023] [Indexed: 06/29/2023] Open
Abstract
Frontline laboratories are adopting culture-independent diagnostic testing (CIDT) such as nucleic acid amplification tests (NAATs) due to numerous advantages over culture-based testing methods. Paradoxically, the viability of pathogens, a crucial factor determining active infections, cannot be confirmed with current NAATs alone. A recent development of viability PCR (vPCR) was introduced to mitigate this limitation associated with real-time PCR (qPCR) by using a DNA-intercalating dye to remove residual and dead cell DNA. This study assessed the applicability of the vPCR assay on diarrheal stools. Eighty-five diarrheal stools confirmed for Salmonellosis were tested via qPCR and vPCR using in-house primers and probe targeting the invA gene. vPCR-negative stools (Ct cut off > 31) were enriched in mannitol selenite broth (MSB) to verify low bacterial loads. vPCR assay showed ~89% sensitivity (qPCR- and vPCR-positive stools: 76/85). vPCR-negative stools (9/85; qPCR-positive: 5; qPCR-negative: 4) were qPCR- and culture-positive post-MSB-enrichment and confirmed the presence of low viable bacterial loads. Random sampling error, low bacterial loads, and receiving stools in batches could contribute to false negatives. This is a pilot study and further investigations are warranted to explore vPCR to assess pathogen viability in a clinical setting, especially when culture-based testing is unavailable.
Collapse
|
4
|
The impact of viability assessment using cardiac MRI and echocardiogram on the outcome of revascularization in patients with multi-vessels coronary artery disease and moderate to severe ischemic cardiomyopathy. Saudi Med J 2023; 44:373-378. [PMID: 37062545 PMCID: PMC10153613 DOI: 10.15537/smj.2023.44.4.20220133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Accepted: 02/18/2023] [Indexed: 04/18/2023] Open
Abstract
OBJECTIVES To investigate the influence of viability assessment in the management of patients with ischemic cardiomyopathy (ICM). METHODS This retrospective cohort study included all patients with ICM with moderate to severely reduced left ventricular ejection fraction (LVEF) who underwent viability assessment using cardiac magnetic resonance imaging (MRI) and echocardiogram as modalities of imaging. In addition, LVEF, modality of choice, and treatment plans were all extracted as main variables from the electronic database. One hundred 6 patients who met the inclusion criteria from December 2014 to December 2019 were included. RESULTS Posttreatment LVEF improved by 5% in the viable group compared to the nonviable group (p=0.016). Regardless of the treatment received, 6 (8.8%) patients in the viable group died due to cardiac causes after an 18-month follow-up period; in contrast, 7 (18.4%) patients died due to cardiac causes in the nonviable group. However, despite that difference, this was not statistically significant (p=0.153). Medical therapy alone was observed in 32 (84.2%) patients in the nonviable group compared to 32 (47.1%) in the viable group (p<0.001). Although the reduction in hospitalization for cardiac reasons was not statistically significant, the viable arm had 50% fewer hospitalizations than the nonviable arm (p=0.051). CONCLUSION Patients with viable myocardium had better outcomes in which LVEF significantly improved posttreatment. Additionally, there was a reduction in the number of hospitalizations for cardiac reasons in the viable group compared to the nonviable group, even though the difference was not statistically significant. However, further studies with a larger number of patients are needed to determine a definite conclusion.
Collapse
|
5
|
How Can Machine Perfusion Change the Paradigm of Liver Transplantation for Patients with Perihilar Cholangiocarcinoma? J Clin Med 2023; 12:jcm12052026. [PMID: 36902813 PMCID: PMC10004136 DOI: 10.3390/jcm12052026] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 02/24/2023] [Accepted: 03/01/2023] [Indexed: 03/08/2023] Open
Abstract
Perihilar cholangiocarcinomas (pCCA) are rare yet aggressive tumors originating from the bile ducts. While surgery remains the mainstay of treatment, only a minority of patients are amenable to curative resection, and the prognosis of unresectable patients is dismal. The introduction of liver transplantation (LT) after neoadjuvant chemoradiation for unresectable pCCA in 1993 represented a major breakthrough, and it has been associated with 5-year survival rates consistently >50%. Despite these encouraging results, pCCA has remained a niche indication for LT, which is most likely due to the need for stringent candidate selection and the challenges in preoperative and surgical management. Machine perfusion (MP) has recently been reintroduced as an alternative to static cold storage to improve liver preservation from extended criteria donors. Aside from being associated with superior graft preservation, MP technology allows for the safe extension of preservation time and the testing of liver viability prior to implantation, which are characteristics that may be especially useful in the setting of LT for pCCA. This review summarizes current surgical strategies for pCCA treatment, with a focus on unmet needs that have contributed to the limited spread of LT for pCCA and how MP could be used in this setting, with a particular emphasis on the possibility of expanding the donor pool and improving transplant logistics.
Collapse
|
6
|
Histopathological evaluation of Onchocerca volvulus nodules by microscopy and by digital image analysis for the study of macrofilaricidal drug efficacy. Front Med (Lausanne) 2023; 10:1099926. [PMID: 36817770 PMCID: PMC9932808 DOI: 10.3389/fmed.2023.1099926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 01/17/2023] [Indexed: 02/05/2023] Open
Abstract
Background Novel drugs or drug combinations that kill or permanently sterilize adult Onchocerca volvulus worms would be very helpful for treatment and elimination of onchocerciasis. In absence of a reliable biomarker for viable adult worms, histopathological assessment of worms within onchocercal nodules is a standard method to determine macrofilaricidal activity. The goal of the present study was to determine the agreement between two independent experts in the analysis of nodule sections and to assess the value of digital imaging as a means of standardizing the analysis. Material and methods Two expert microscopists independently assessed 605 nodules by direct microscopy. At least two sections with two different stains hematoxylin & eosin (H&E, APR immunostain) of paraffin-embedded, ethanol-fixed whole-nodule cross-sections were analyzed. After variables were identified prone to observer discrepancies, we performed a second study to compare consolidated results for 100 nodules obtained by the two readers by microscopy and by analysis of scanned, high resolution digital images (20x magnification). The last data set analyzed was a quality panel of 100 nodules that has been previously examined by microscopy, and included additional immunostains for Wolbachia endobacteria. These slides were digitalized, read by the two assessors and results were compared with original microscopy results. Results The degree of agreement between assessors varied for different parameters. Agreement for female worm counts in nodules was approximately 80%, while agreement regarding female worm viability was 98%. There were no major differences observed between results obtained by microscopy or digital images. Good agreement for important parameters was also observed for the nodules of the quality panel. Conclusion Nodule analysis by experienced microscopists was reproducible with regard to important parameters such as identification of living female worms or detection of normal embryogenesis. Assessments varied more for other parameters, and we recommend continued use of two independent readers for detailed analyzes. Analysis of scanned images provided similar results to direct microscopy. This facilitates training and comparison of nodule findings by readers in different locations. Analysis of high quality digital images that can be viewed remotely should improve the quality and availability of nodule assessments that are primary endpoints for onchocerciasis clinical trials.
Collapse
|
7
|
Recent Methods for the Viability Assessment of Bacterial Pathogens: Advances, Challenges, and Future Perspectives. Pathogens 2022; 11:pathogens11091057. [PMID: 36145489 PMCID: PMC9500772 DOI: 10.3390/pathogens11091057] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/14/2022] [Accepted: 09/15/2022] [Indexed: 11/28/2022] Open
Abstract
Viability assessment is a critical step in evaluating bacterial pathogens to determine infectious risks to public health. Based on three accepted viable criteria (culturability, metabolic activity, and membrane integrity), current viability assessments are categorized into three main strategies. The first strategy relies on the culturability of bacteria. The major limitation of this strategy is that it cannot detect viable but nonculturable (VBNC) bacteria. As the second strategy, based on the metabolic activity of bacteria, VBNC bacteria can be detected. However, VBNC bacteria sometimes can enter a dormant state that allows them to silence reproduction and metabolism; therefore, they cannot be detected based on culturability and metabolic activity. In order to overcome this drawback, viability assessments based on membrane integrity (third strategy) have been developed. However, these techniques generally require multiple steps, bulky machines, and laboratory technicians to conduct the tests, making them less attractive and popular applications. With significant advances in microfluidic technology, these limitations of current technologies for viability assessment can be improved. This review summarized and discussed the advances, challenges, and future perspectives of current methods for the viability assessment of bacterial pathogens.
Collapse
|
8
|
Unraveling metabolism during kidney perfusion using tracer studies, a systematic review. Artif Organs 2022; 46:2118-2134. [PMID: 35848397 DOI: 10.1111/aor.14355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 06/02/2022] [Accepted: 07/03/2022] [Indexed: 12/09/2022]
Abstract
BACKGROUND Understanding kidney metabolism during perfusion is vital to further develop the technology as a preservation, viability assessment, and resuscitation platform. We reviewed the evidence on the use of labeled metabolites (tracers) to understand "on-pump" kidney behavior. METHODS PubMed, Embase, Web of Science, and Cochrane databases were systematically searched for studies evaluating metabolism of (non)radioactively labeled endogenous compounds during kidney perfusion. RESULTS Of 5899 articles, 30 were included. All were animal studies [rat (70%), dog (13%), pig (10%), rabbit (7%)] perfusing but not transplanting kidneys. Perfusion took place at hypothermic (4-12°C) (20%), normothermic (35-40°C) (77%), or undefined temperatures (3%). Hypothermic perfusion used albumin or a clinical kidney preservation solution, mostly in the presence of oxygen. Normothermic perfusion was mostly performed with oxygenated crystalloids often containing glucose and amino acids with unclear partial oxygen tensions. Active metabolism of carbohydrate, amino acid, lipids, and large molecules was shown in hypothermic and normothermic perfusion. Production of macromolecules, such as prostaglandin, thromboxane, and vitamin D, takes place during normothermic perfusion. No experiments compared differences in metabolic activity between hypothermic and normothermic perfusion. One conference abstract showed increased anaerobic metabolism in kidneys donated after circulatory death by adding labeled glucose to hypothermically perfused human kidneys. CONCLUSIONS Tracer studies during kidney perfusion contribute to unraveling kidney metabolic behavior in pre-clinical models. Whether findings are truly translational needs further investigation in large animal models of human kidneys. Furthermore, it is essential to better understand how ischemia changes this metabolic behavior.
Collapse
|
9
|
On-Chip Optical Nano-Tweezers for Culture-Less Fast Bacterial Viability Assessment. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2103765. [PMID: 34784093 DOI: 10.1002/smll.202103765] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 09/30/2021] [Indexed: 06/13/2023]
Abstract
Because of antibiotics misuse, the dramatic growth of antibioresistance threatens public health. Tests are indeed culture-based, and require therefore one to two days. This long time-to-result implies the use of large-spectrum antibiotherapies as a first step, in absence of pathogen characterization. Here, a breakthrough approach for a culture-less fast assessment of bacterial response to stress is proposed. It is based on non-destructive on-chip optical tweezing. A laser loads an optical nanobeam cavity whose evanescent part of the resonant field acts as a nano-tweezer for bacteria surrounding the cavity. Once optically trapped, the bacterium-nanobeam cavity interaction induces a shift of the resonance driven by the bacterial cell wall optical index. The analysis of the wavelength shift yields an assessment of viability upon stress at the single-cell scale. As a proof of concept, bacteria are stressed by incursion, before optical trapping, at different temperatures (45, 51, and 70 °C). Optical index changes correlate with the degree of thermal stress allowing to sort viable and dead bacteria. With this disruptive diagnosis method, bacterial viability upon stress is probed much faster (typically less than 4 h) than with conventional culture-based enumeration methods (24 h).
Collapse
|
10
|
Heterogeneous indications and the need for viability assessment: An international survey on the use of machine perfusion in liver transplantation. Artif Organs 2021; 46:296-305. [PMID: 34460943 PMCID: PMC9291461 DOI: 10.1111/aor.14061] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 07/28/2021] [Accepted: 08/16/2021] [Indexed: 02/06/2023]
Abstract
Although machine perfusion (MP) is being increasingly adopted in liver transplantation, indications, timing, and modality are debated. To investigate current indications for MP a web‐based Google Forms survey was launched in January 2021 and addressed to 127 experts in the field, identified among first and corresponding Authors of MP literature in the last 10 years. The survey presented 10 real‐life cases of donor–recipient matching, asking whether the liver would be accepted (Q1), whether MP would be used in that particular setting (Q2) and, if so, by which MP modality (Q3) and at what timing during preservation (Q4). Respondents could also comment on each case. The agreement was evaluated using Krippendorff's alpha coefficient. Answers from 39 (30.1%) participants disclosed significant heterogeneity in graft acceptance, MP indications, technique, and timing. Agreement between respondents was generally poor (Q1, α = 0.11; Q2, α = 0.14; Q3, α = 0.12, Q4, α = 0.11). Overall, respondents preferred hypothermic MP and an end‐ischemic approach in 56.3% and 81.1% of cases, respectively. A total of 18 (46.2%) participants considered only one MP approach, whereas 17 (43.6%) and 3 (7.7%) considered using alternatively 2 or 3 different techniques. Of 38 comments, 17 (44.7%) were about the use of MP for graft viability assessment before implantation. This survey shows considerable variability in MP indications, emphasizing the need to identify scenarios of optimal utilization for each technique. Viability assessment emerges as a fundamental need of transplant professionals when considering the use of MP.
Collapse
|
11
|
Automated mesenchymal stem cell segmentation and machine learning-based phenotype classification using morphometric and textural analysis. J Med Imaging (Bellingham) 2021; 8:014503. [PMID: 33542945 PMCID: PMC7849042 DOI: 10.1117/1.jmi.8.1.014503] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2020] [Accepted: 01/11/2021] [Indexed: 01/22/2023] Open
Abstract
Purpose: Mesenchymal stem cells (MSCs) have demonstrated clinically relevant therapeutic effects for treatment of trauma and chronic diseases. The proliferative potential, immunomodulatory characteristics, and multipotentiality of MSCs in monolayer culture is reflected by their morphological phenotype. Standard techniques to evaluate culture viability are subjective, destructive, or time-consuming. We present an image analysis approach to objectively determine morphological phenotype of MSCs for prediction of culture efficacy. Approach: The algorithm was trained using phase-contrast micrographs acquired during the early and mid-logarithmic stages of MSC expansion. Cell regions are localized using edge detection, thresholding, and morphological operations, followed by cell marker identification using H-minima transform within each region to differentiate individual cells from cell clusters. Clusters are segmented using marker-controlled watershed to obtain single cells. Morphometric and textural features are extracted to classify cells based on phenotype using machine learning. Results: Algorithm performance was validated using an independent test dataset of 186 MSCs in 36 culture images. Results show 88% sensitivity and 86% precision for overall cell detection and a mean Sorensen-Dice coefficient of 0.849 ± 0.106 for segmentation per image. The algorithm exhibited an area under the curve of 0.816 (CI 95 = 0.769 to 0.886) and 0.787 (CI 95 = 0.716 to 0.851) for classifying MSCs according to their phenotype at early and mid-logarithmic expansion, respectively. Conclusions: The proposed method shows potential to segment and classify low and moderately dense MSCs based on phenotype with high accuracy and robustness. It enables quantifiable and consistent morphology-based quality assessment for various culture protocols to facilitate cytotherapy development.
Collapse
|
12
|
Kidney Perfusion as an Organ Quality Assessment Tool-Are We Counting Our Chickens Before They Have Hatched? J Clin Med 2020; 9:jcm9030879. [PMID: 32210197 PMCID: PMC7141526 DOI: 10.3390/jcm9030879] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 03/16/2020] [Accepted: 03/19/2020] [Indexed: 02/07/2023] Open
Abstract
The final decision to accept an organ for transplantation remains a subjective one. With “poor organ quality” commonly cited as a major reason for kidney discard, accurate, objective, and reliable quality assessment is essential. In an era of increasingly higher-risk deceased donor kidneys, the catch is to accept those where the risk–benefit scale will tip in the right direction. Currently available assessment tools, such as risk-scores predicting outcome and zero-time biopsy, perform unsatisfactory, and assessment options during static cold storage are limited. Kidney perfusion technologies are finding their way into clinical practice, and they bring a new opportunity to assess kidney graft viability and quality, both in hypothermic and normothermic conditions. We give an overview of the current understanding of kidney viability assessment during ex situ kidney perfusion. A pragmatic framework to approach viability assessment is proposed as an interplay of three different compartments: the nephron, the vascular compartment, and the immune compartment. Although many interesting ways to assess kidney injury and function during perfusion have been proposed, none have reached the stage where they can reliably predict posttransplant outcome. Larger well-designed studies and validation cohorts are needed to provide better guidance.
Collapse
|
13
|
Abstract
Machine perfusion is a hot topic in liver transplantation and several new perfusion concepts are currently developed. Prior to introduction into routine clinical practice, however, such perfusion approaches need to demonstrate their impact on liver function, post-transplant complications, utilization rates of high-risk organs, and cost benefits. Therefore, based on results of experimental and clinical studies, the community has to recognize the limitations of this technology. In this review, we summarize current perfusion concepts and differences between protective mechanisms of ex- and in-situ perfusion techniques. Next, we discuss which graft types may benefit most from perfusion techniques, and highlight the current understanding of liver viability testing. Finally, we present results from recent clinical trials involving machine liver perfusion, and analyze the value of different outcome parameters, currently used as endpoints for randomized controlled trials in the field.
Collapse
|
14
|
Noninvasive assessment of tissue-engineered graft viability by oxygen-17 magnetic resonance spectroscopy. Biotechnol Bioeng 2016; 114:1118-1121. [PMID: 27869295 DOI: 10.1002/bit.26227] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2016] [Revised: 10/27/2016] [Accepted: 11/14/2016] [Indexed: 02/05/2023]
Abstract
Transplantation of macroencapsulated tissue-engineered grafts (TEGs) is being investigated as a treatment for type 1 diabetes, but there is a critical need to measure TEG viability both in vitro and in vivo. Oxygen deficiency is the most critical issue preventing widespread implementation of TEG transplantation and delivery of supplemental oxygen (DSO) has been shown to enhance TEG survival and function in vivo. In this study, we demonstrate the first use of oxygen-17 magnetic resonance spectroscopy (17 O-MRS) to measure the oxygen consumption rate (OCR) of TEGs and show that in addition to providing therapeutic benefits to TEGs, DSO with 17 O2 can also enable measurements of TEG viability. Macroencapsulated TEGs containing βTC3 murine insulinoma cells were prepared with three fractional viabilities and provided with 17 O2 . Cellular metabolism of 17 O2 into nascent mitochondrial water (H217 O) was monitored by 17 O-MRS and, from the measured data, OCR was calculated. For comparison, OCR was simultaneously measured on a separate, but equivalent sample of cells with a well-established stirred microchamber technique. OCR measured by 17 O-MRS agreed well with measurements made in the stirred microchamber device. These studies confirm that 17 O-MRS can quantify TEG viability noninvasively. Biotechnol. Bioeng. 2017;114: 1118-1121. © 2016 Wiley Periodicals, Inc.
Collapse
|
15
|
Hypothermic machine perfusion of kidneys retrieved from standard and high-risk donors. Transpl Int 2015; 28:665-76. [PMID: 25630347 DOI: 10.1111/tri.12530] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2014] [Revised: 12/23/2014] [Accepted: 01/22/2015] [Indexed: 01/15/2023]
Abstract
Hypothermic machine perfusion (HMP) of kidneys is a long-established alternative to static cold storage and has been suggested to be a better preservation method. Today, as our deceased donor profile continues to change towards higher-risk kidneys of lower quality, we are confronted with the limits of cold storage. Interest in HMP as a preservation technique is on the rise. Furthermore, HMP also creates a window of opportunity during which to assess the viability and quality of the graft before transplantation. The technology might also provide a platform during which the graft could be actively repaired, making it particularly attractive for higher-risk kidneys. We review the current evidence on HMP in kidney transplantation and provide an outlook for the use of the technology in the years to come.
Collapse
|
16
|
A novel system for in situ determination of heat tolerance of plants: first results on alpine dwarf shrubs. PLANT METHODS 2013; 9:7. [PMID: 23497517 PMCID: PMC3602033 DOI: 10.1186/1746-4811-9-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2012] [Accepted: 03/07/2013] [Indexed: 05/09/2023]
Abstract
BACKGROUND Heat stress and heat damage to plants gain globally increasing importance for crop production and plant survival in endangered habitats. Therefore the knowledge of heat tolerance of plants is of great interest. As many heat tolerance measurement procedures require detachment of plants and protocols expose samples to various heat temperatures in darkness, the ecological relevance of such results may be doubted. To overcome these constraints we designed a novel field compatible Heat Tolerance Testing System (HTTS) that opens the opportunity to induce controlled heat stress on plants in situ under full natural solar irradiation. Subsequently, heat tolerance can be evaluated by a variety of standard viability assays like the electrolyte leakage test, chlorophyll fluorescence measurements and visual assessment methods. Furthermore, recuperation can be studied under natural environmental conditions which is impossible when detached plant material is used. First results obtained on three alpine dwarf - shrubs are presented. RESULTS When heat tolerance of Vaccinium gaultherioides Bigelow was tested with the HTTS in situ, the visual assessment of leaves showed 50% heat injury (LT50) at 48.3°C, while on detached leaves where heat exposure took place in small heat chambers this already happened at 45.8°C. Natural solar irradiation being applied during heat exposure in the HTTS had significantly protective effects: In Loiseleuria procumbens L. (Desv.), if heat exposure (in situ) took place in darkness, leaf heat tolerance was 50.6°C. In contrast, when heat exposure was conducted under full natural solar irradiation heat tolerance was increased to 53.1°C. In Rhododendron ferrugineum L. heat tolerance of leaves was 42.5°C if the exposure took place ex situ and in darkness, while it was significantly increased to 45.8°C when this happened in situ under natural solar irradiation. CONCLUSIONS The results obtained with the HTTS tested in the field indicate a mitigating effect of natural solar irradiation during heat exposure. Commonly used laboratory based measurement procedures expose samples in darkness and seem to underestimate leaf heat tolerance. Avoidance of detachment by the use of the HTTS allows studying heat tolerance and recuperation processes in the presence of interacting external abiotic, biotic and genetic factors under field conditions. The investigation of combined effects of heat exposure under full solar irradiation, of recuperation and repair processes but also of possible damage amplification into the results with the HTTS appears to be particularly useful as it allows determining heat tolerance of plants with a considerably high ecological significance.
Collapse
|
17
|
Myocardial viability assessment: poor correlation between electromechanical cardiac mapping and positron emission tomography in severe coronary artery disease. Neth Heart J 2005; 13:305-311. [PMID: 25696517 PMCID: PMC2497261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023] Open
Abstract
BACKGROUND An intracardial electromechanical mapping system has recently been introduced which offers the ability to perform on-line myocardial viability assessment in the catheterisation laboratory. Only a small number of studies have been performed to validate this potentially very useful technique. AIM We sought to assess the correlation between viability assessment performed with both positron emission tomography (PET) and electromechanical cardiac mapping (EMM) in patients suffering from severe coronary artery disease, since PET is considered the golden standard in myocardial viability assessment. METHODS Patients undergoing both EMM and PET analysis were systematically scanned for viability assessment. EMM analysis was performed for both linear local shortening and unipolar voltage. PET analysis consisted of dipyridamole stress and fluoro-deoxy-d-glucose (FDG) measurements. All data were converted to nine-segment bull's-eye maps to allow comparison. One single operator analysed all the data, blinded for clinical status. RESULTS 34 patients suffering from severe coronary artery disease underwent both PET and EMM analysis. In total 253 EMM segments had more than four contact points and could be used for analysis. Unipolar voltage showed a trend towards lower values in infarcted segments; however, linear local shortening did not show any correlation. CONCLUSION In this study viability assessment by EMM did not correspond with PET analysis. Although the advantage of having some form of online myocardial assessment is evident, operators should bare in mind that the quantitative EMM measurements are not an absolute substitute for nuclear imaging.
Collapse
|