1
|
Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, Leprince P, Leguerrier A, Lievre M, Prat A, Teiger E, Lefevre T, Himbert D, Tchetche D, Carrié D, Albat B, Cribier A, Rioufol G, Sudre A, Blanchard D, Collet F, Dos Santos P, Meneveau N, Tirouvanziam A, Caussin C, Guyon P, Boschat J, Le Breton H, Collart F, Houel R, Delpine S, Souteyrand G, Favereau X, Ohlmann P, Doisy V, Grollier G, Gommeaux A, Claudel JP, Bourlon F, Bertrand B, Van Belle E, Laskar M. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 2012; 366:1705-15. [PMID: 22551129 DOI: 10.1056/nejmoa1114705] [Citation(s) in RCA: 961] [Impact Index Per Article: 73.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Transcatheter aortic-valve implantation (TAVI) is an emerging intervention for the treatment of high-risk patients with severe aortic stenosis and coexisting illnesses. We report the results of a prospective multicenter study of the French national transcatheter aortic-valve implantation registry, FRANCE 2. METHODS All TAVIs performed in France, as listed in the FRANCE 2 registry, were prospectively included in the study. The primary end point was death from any cause. RESULTS A total of 3195 patients were enrolled between January 2010 and October 2011 at 34 centers. The mean (±SD) age was 82.7±7.2 years; 49% of the patients were women. All patients were highly symptomatic and were at high surgical risk for aortic-valve replacement. Edwards SAPIEN and Medtronic CoreValve devices were implanted in 66.9% and 33.1% of patients, respectively. Approaches were either transarterial (transfemoral, 74.6%; subclavian, 5.8%; and other, 1.8%) or transapical (17.8%). The procedural success rate was 96.9%. Rates of death at 30 days and 1 year were 9.7% and 24.0%, respectively. At 1 year, the incidence of stroke was 4.1%, and the incidence of periprosthetic aortic regurgitation was 64.5%. In a multivariate model, a higher logistic risk score on the European System for Cardiac Operative Risk Evaluation (EuroSCORE), New York Heart Association functional class III or IV symptoms, the use of a transapical TAVI approach, and a higher amount of periprosthetic regurgitation were significantly associated with reduced survival. CONCLUSIONS This prospective registry study reflected real-life TAVI experience in high-risk elderly patients with aortic stenosis, in whom TAVI appeared to be a reasonable option. (Funded by Edwards Lifesciences and Medtronic.).
Collapse
|
|
13 |
961 |
2
|
Sosa E, Scanavacca M, d'Avila A, Pilleggi F. A new technique to perform epicardial mapping in the electrophysiology laboratory. J Cardiovasc Electrophysiol 1996; 7:531-6. [PMID: 8743758 DOI: 10.1111/j.1540-8167.1996.tb00559.x] [Citation(s) in RCA: 645] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
INTRODUCTION A possible epicardial site of origin may be the reason for unsuccessful endocardial application of radiofrequency energy to control recurrent ventricular tachycardia. This study tests the feasibility and safety of a new epicardial mapping technique in patients with Chagas' disease and recurrent ventricular tachycardia. METHODS AND RESULTS Epicardial mapping was performed through a pericardial puncture as an epidural introducer needle was advanced into the pericardial space under fluoroscopic guidance. Medium contrast was injected to demonstrate the position of the needle tip, and a guidewire was introduced until its tip lay within the pericardial space. A 8-French Hemaquet was advanced and 4-mm deflectable tip catheter introduced into the pericardial sac to map the right and left ventricular epicardium. Transthoracic echocardiographic monitoring was performed on the day of the procedure and on the day of hospital discharge. The pericardial space was reached in all patients with no complications. Electrophysiologic data suggesting the existence of an epicardial circuit was found in one patient. No complications occurred during the hospitalization period. CONCLUSION Epicardial mapping can be safely performed through a pericardial puncture in the electrophysiology laboratory.
Collapse
|
|
29 |
645 |
3
|
Kiemeneij F, Laarman GJ, Odekerken D, Slagboom T, van der Wieken R. A randomized comparison of percutaneous transluminal coronary angioplasty by the radial, brachial and femoral approaches: the access study. J Am Coll Cardiol 1997; 29:1269-75. [PMID: 9137223 DOI: 10.1016/s0735-1097(97)00064-8] [Citation(s) in RCA: 625] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES This study sought to compare procedural and clinical outcomes of percutaneous transluminal coronary angioplasty (PTCA) performed with 6F guiding catheters introduced through the radial, brachial or femoral arteries. BACKGROUND Transradial PTCA has been demonstrated to be an effective and safe alternative to transfemoral PTCA; however, no randomized data are currently available. METHODS A randomized comparison between transradial, transbrachial and transfemoral PTCA with 6F guiding catheters was performed in 900 patients. Primary end points were entry site and angioplasty related. Secondary end points were quantitative coronary analysis after PTCA, procedural and fluoroscopy times, consumption of angioplasty equipment and length of hospital stay. RESULTS Successful coronary cannulation was achieved in 279 (93.0%), 287 (95.7%) and 299 (99.7%) patients randomized to undergo PTCA by the radial, brachial and femoral approaches, respectively. PTCA success was achieved in 91.7%, 90.7% and 90.7% (p = NS) of patients, with 88.0%, 87.7% and 90.0% event free at 1-month follow-up, respectively (p = NS). Major entry site complications were encountered in seven patients (2.3%) in the transbrachial group, six (2.0%) in the transfemoral group and none in the transradial group (p = 0.035). Transradial PTCA led to asymptomatic loss of radial pulsations in nine patients (3%). Procedural and fluoroscopy times were similar, as were consumption of guiding and balloon catheters and length of hospital stay ([mean +/- SD] 1.5 +/- 2.5, 1.8 +/- 3.8 and 1.8 +/- 4.2 days, respectively). CONCLUSIONS With experience, procedural and clinical outcomes of PTCA were similar for the three subgroups, but access failure is more common during transradial PTCA. Major access site complications were more frequently encountered after transbrachial and transfemoral PTCA.
Collapse
|
Clinical Trial |
28 |
625 |
4
|
Pacher P, Nagayama T, Mukhopadhyay P, Bátkai S, Kass DA. Measurement of cardiac function using pressure-volume conductance catheter technique in mice and rats. Nat Protoc 2008; 3:1422-34. [PMID: 18772869 PMCID: PMC2597499 DOI: 10.1038/nprot.2008.138] [Citation(s) in RCA: 598] [Impact Index Per Article: 35.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Ventricular pressure-volume relationships have become well established as the most rigorous and comprehensive ways to assess intact heart function. Thanks to advances in miniature sensor technology, this approach has been successfully translated to small rodents, allowing for detailed characterization of cardiovascular function in genetically engineered mice, testing effects of pharmacotherapies and studying disease conditions. This method is unique for providing measures of left ventricular (LV) performance that are more specific to the heart and less affected by vascular loading conditions. Here we present descriptions and movies for procedures employing this method (anesthesia, intubation and surgical techniques, calibrations). We also provide examples of hemodynamics measurements obtained from normal mice/rats, and from animals with cardiac hypertrophy/heart failure, and describe values for various useful load-dependent and load-independent indexes of LV function obtained using different types of anesthesia. The completion of the protocol takes 1-4 h (depending on the experimental design/end points).
Collapse
|
Research Support, N.I.H., Extramural |
17 |
598 |
5
|
Campeau L. Percutaneous radial artery approach for coronary angiography. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS 1989; 16:3-7. [PMID: 2912567 DOI: 10.1002/ccd.1810160103] [Citation(s) in RCA: 563] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Percutaneous entry into the distal radial artery and selective coronarography using a French 5 sheath and preshaded catheters were attempted in 100 patients with a normal Allen test. Cannulation of the radial artery was not possible in ten patients, and selective catheterization of the coronary arteries was unsuccessful in two. Manipulation of catheters presented no problem, and arterial spasm was rarely observed, only before the use of a 23-cm-long sheath. Only two complications without symptoms were observed: arterial dissection of the brachial artery in one patient and occlusion of the radial artery in another. With experience, this approach may become as effective and possibly safer than the transbrachial entry.
Collapse
|
|
36 |
563 |
6
|
Coghlan JG, Denton CP, Grünig E, Bonderman D, Distler O, Khanna D, Müller-Ladner U, Pope JE, Vonk MC, Doelberg M, Chadha-Boreham H, Heinzl H, Rosenberg DM, McLaughlin VV, Seibold JR, on behalf of the DETECT study group. Evidence-based detection of pulmonary arterial hypertension in systemic sclerosis: the DETECT study. Ann Rheum Dis 2014; 73:1340-9. [PMID: 23687283 PMCID: PMC4078756 DOI: 10.1136/annrheumdis-2013-203301] [Citation(s) in RCA: 558] [Impact Index Per Article: 50.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/14/2013] [Indexed: 02/06/2023]
Abstract
OBJECTIVE Earlier detection of pulmonary arterial hypertension (PAH), a leading cause of death in systemic sclerosis (SSc), facilitates earlier treatment. The objective of this study was to develop the first evidence-based detection algorithm for PAH in SSc. METHODS In this cross-sectional, international study conducted in 62 experienced centres from North America, Europe and Asia, adults with SSc at increased risk of PAH (SSc for >3 years and predicted pulmonary diffusing capacity for carbon monoxide <60%) underwent a broad panel of non-invasive assessments followed by diagnostic right heart catheterisation (RHC). Univariable and multivariable analyses selected the best discriminatory variables for identifying PAH. After assessment for clinical plausibility and feasibility, these were incorporated into a two-step, internally validated detection algorithm. Nomograms for clinical practice use were developed. RESULTS Of 466 SSc patients at increased risk of PAH, 87 (19%) had RHC-confirmed PAH. PAH was mild (64% in WHO functional class I/II). Six simple assessments in Step 1 of the algorithm determined referral to echocardiography. In Step 2, the Step 1 prediction score and two echocardiographic variables determined referral to RHC. The DETECT algorithm recommended RHC in 62% of patients (referral rate) and missed 4% of PAH patients (false negatives). By comparison, applying European Society of Cardiology/European Respiratory Society guidelines to these patients, 29% of diagnoses were missed while requiring an RHC referral rate of 40%. CONCLUSIONS The novel, evidence-based DETECT algorithm for PAH detection in SSc is a sensitive, non-invasive tool which minimises missed diagnoses, identifies milder disease and addresses resource usage.
Collapse
|
research-article |
11 |
558 |
7
|
Feltes TF, Bacha E, Beekman RH, Cheatham JP, Feinstein JA, Gomes AS, Hijazi ZM, Ing FF, de Moor M, Morrow WR, Mullins CE, Taubert KA, Zahn EM. Indications for cardiac catheterization and intervention in pediatric cardiac disease: a scientific statement from the American Heart Association. Circulation 2011; 123:2607-52. [PMID: 21536996 DOI: 10.1161/cir.0b013e31821b1f10] [Citation(s) in RCA: 546] [Impact Index Per Article: 39.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
Practice Guideline |
14 |
546 |
8
|
Gallagher JJ, Svenson RH, Kasell JH, German LD, Bardy GH, Broughton A, Critelli G. Catheter technique for closed-chest ablation of the atrioventricular conduction system. N Engl J Med 1982; 306:194-200. [PMID: 7054682 DOI: 10.1056/nejm198201283060402] [Citation(s) in RCA: 526] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
This report describes a catheter technique for ablating the His bundle and its application in nine patients with recurrent supraventricular tachycardia that was unresponsive to medical management. A tripolar electrode catheter was positioned in the region of the His bundle, and the electrode recording a large unipolar His-bundle potential was identified. In the first patient, two shocks of 25 and 50 J, respectively, were delivered by a standard cardioversion unit to the catheter electrode, resulting in an intra-His-bundle conduction defect. Subsequent delivery of 300 J resulted in complete heart block. In the next eight patients, an initial shock of 200 J was used. The His bundle was ablated by this single shock in six of these patients and by an additional shock of 300 J in one. In the remaining patient, conduction in the atrioventricular node was modified, resulting in alternating first and second-degree atrioventricular block. A stable escape rhythm was preserved in all patients. The procedure was well tolerated, without complications, and all patients have remained free of arrhythmia, without medication, for follow-up periods of two to six months.
Collapse
|
|
43 |
526 |
9
|
Kasner M, Westermann D, Steendijk P, Gaub R, Wilkenshoff U, Weitmann K, Hoffmann W, Poller W, Schultheiss HP, Pauschinger M, Tschöpe C. Utility of Doppler echocardiography and tissue Doppler imaging in the estimation of diastolic function in heart failure with normal ejection fraction: a comparative Doppler-conductance catheterization study. Circulation 2007; 116:637-47. [PMID: 17646587 DOI: 10.1161/circulationaha.106.661983] [Citation(s) in RCA: 451] [Impact Index Per Article: 25.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Various conventional and tissue Doppler echocardiographic indexes were compared with pressure-volume loop analysis to assess their accuracy in detecting left ventricular (LV) diastolic dysfunction in patients with heart failure with normal ejection fraction (HFNEF). METHODS AND RESULTS Diastolic dysfunction was confirmed by pressure-volume loop analysis obtained by conductance catheter in 43 patients (19 men) with HFNEF. Their Doppler indexes were compared with those of 12 control patients without heart failure symptoms and with normal ejection fraction. Invasively measured indexes for diastolic relaxation (tau, dP/dt(min)), LV end-diastolic pressure, and LV end-diastolic pressure-volume relationship (stiffness, b [dP/dV], and stiffness constant, beta) were correlated with several conventional mitral flow and tissue Doppler imaging indexes. Conventional Doppler indexes correlated moderately with the degree of LV relaxation index, tau (E/A: r=-0.36, P=0.013; isovolumic relaxation time: r=0.31, P=0.040) and b (deceleration time: r=0.39, P=0.012) but not with beta, in contrast to the tissue Doppler imaging indexes E'/A'(lateral) (r=-0.37, P=0.008) and E/E'(lateral) (r=0.53, P<0.001). Diastolic dysfunction was detected in 70% of the HFNEF patients by mitral flow Doppler but in 81% and 86% by E'/A'(lateral), and E/E'(lateral), respectively. CONCLUSIONS Of all echocardiographic parameters investigated, the LV filling index E/E'(lateral) was identified as the best index to detect diastolic dysfunction in HFNEF in which the diagnosis of diastolic dysfunction was confirmed by conductance catheter analysis. We recommend its use as an essential tool for noninvasive diagnostics of diastolic function in patients with HFNEF.
Collapse
|
Research Support, Non-U.S. Gov't |
18 |
451 |
10
|
Hayashida K, Lefèvre T, Chevalier B, Hovasse T, Romano M, Garot P, Mylotte D, Uribe J, Farge A, Donzeau-Gouge P, Bouvier E, Cormier B, Morice MC. Transfemoral aortic valve implantation new criteria to predict vascular complications. JACC Cardiovasc Interv 2011; 4:851-8. [PMID: 21851897 DOI: 10.1016/j.jcin.2011.03.019] [Citation(s) in RCA: 425] [Impact Index Per Article: 30.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2011] [Revised: 04/11/2011] [Accepted: 05/25/2011] [Indexed: 12/15/2022]
Abstract
OBJECTIVES This study sought to evaluate the incidence, impact, and predictors of vascular complications in transcatheter aortic valve implantation (TAVI). BACKGROUND Vascular complications increase morbidity and mortality in transfemoral TAVI; however, there remains a paucity of data describing these serious events. METHODS We performed a prospective cohort study of 130 consecutive transfemoral TAVI recipients. Vascular complications were defined by the Valve Academic Research Consortium (VARC) criteria. The ratio of the sheath outer diameter (in millimeters) to the minimal femoral artery diameter (in millimeters) defined the sheath to femoral artery ratio (SFAR). RESULTS In our cohort of elderly patients (83.3 ± 5.9 years), the logistic EuroScore was 25.8% ± 11.9%. The Edwards valve was used in 102 cases (18- to 24-F) and the CoreValve in 27 (18-F). The minimal femoral artery diameter was 8.17 ± 1.14 mm, and the calcification (0 to 3) and tortuosity scores (0 to 3) were 0.58 ± 0.72 and 0.28 ± 0.53, respectively. The mean sheath diameter was 8.10 ± 0.82 mm, and the mean SFAR was 0.99 ± 0.16. Vascular complications occurred in 27.6% (VARC major: 17.3%, minor: 10.2%), and major vascular complications predicted 30-day mortality (22.7% vs. 7.6%, p = 0.049). The SFAR (hazard ratio [HR]: 186.20, 95% confidence interval [CI]: 4.41 to 7,855.11), center experience (HR: 3.66, 95% CI: 1.17 to 11.49), and femoral calcification (HR: 3.44, 95% CI: 1.16 to 10.17) predicted major complications by multivariate analysis. An SFAR threshold of 1.05 (area under the curve = 0.727) predicted a higher rate of VARC major complications (30.9% vs. 6.9%, p = 0.001) and 30-day mortality (18.2% vs. 4.2%, p = 0.016). CONCLUSIONS Vascular complications in transfemoral TAVI are relatively frequent. VARC major vascular complications increase 30-day mortality and are predicted by experience, femoral calcification, and SFAR. Routine application of SFAR will improve patient selection for transfemoral TAVI and may improve outcome.
Collapse
|
Research Support, Non-U.S. Gov't |
14 |
425 |
11
|
Sorajja P, Whisenant B, Hamid N, Naik H, Makkar R, Tadros P, Price MJ, Singh G, Fam N, Kar S, Schwartz JG, Mehta S, Bae R, Sekaran N, Warner T, Makar M, Zorn G, Spinner EM, Trusty PM, Benza R, Jorde U, McCarthy P, Thourani V, Tang GHL, Hahn RT, Adams DH. Transcatheter Repair for Patients with Tricuspid Regurgitation. N Engl J Med 2023; 388:1833-1842. [PMID: 36876753 DOI: 10.1056/nejmoa2300525] [Citation(s) in RCA: 421] [Impact Index Per Article: 210.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/07/2023]
Abstract
BACKGROUND Severe tricuspid regurgitation is a debilitating condition that is associated with substantial morbidity and often with poor quality of life. Decreasing tricuspid regurgitation may reduce symptoms and improve clinical outcomes in patients with this disease. METHODS We conducted a prospective randomized trial of percutaneous tricuspid transcatheter edge-to-edge repair (TEER) for severe tricuspid regurgitation. Patients with symptomatic severe tricuspid regurgitation were enrolled at 65 centers in the United States, Canada, and Europe and were randomly assigned in a 1:1 ratio to receive either TEER or medical therapy (control). The primary end point was a hierarchical composite that included death from any cause or tricuspid-valve surgery; hospitalization for heart failure; and an improvement in quality of life as measured with the Kansas City Cardiomyopathy Questionnaire (KCCQ), with an improvement defined as an increase of at least 15 points in the KCCQ score (range, 0 to 100, with higher scores indicating better quality of life) at the 1-year follow-up. The severity of tricuspid regurgitation and safety were also assessed. RESULTS A total of 350 patients were enrolled; 175 were assigned to each group. The mean age of the patients was 78 years, and 54.9% were women. The results for the primary end point favored the TEER group (win ratio, 1.48; 95% confidence interval, 1.06 to 2.13; P = 0.02). The incidence of death or tricuspid-valve surgery and the rate of hospitalization for heart failure did not appear to differ between the groups. The KCCQ quality-of-life score changed by a mean (±SD) of 12.3±1.8 points in the TEER group, as compared with 0.6±1.8 points in the control group (P<0.001). At 30 days, 87.0% of the patients in the TEER group and 4.8% of those in the control group had tricuspid regurgitation of no greater than moderate severity (P<0.001). TEER was found to be safe; 98.3% of the patients who underwent the procedure were free from major adverse events at 30 days. CONCLUSIONS Tricuspid TEER was safe for patients with severe tricuspid regurgitation, reduced the severity of tricuspid regurgitation, and was associated with an improvement in quality of life. (Funded by Abbott; TRILUMINATE Pivotal ClinicalTrials.gov number, NCT03904147.).
Collapse
|
Multicenter Study |
2 |
421 |
12
|
Cooper CJ, El-Shiekh RA, Cohen DJ, Blaesing L, Burket MW, Basu A, Moore JA. Effect of transradial access on quality of life and cost of cardiac catheterization: A randomized comparison. Am Heart J 1999; 138:430-6. [PMID: 10467191 DOI: 10.1016/s0002-8703(99)70143-2] [Citation(s) in RCA: 401] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND Transradial access is a recently developed alternative for diagnostic cardiac catheterization. Its effects on quality of life after the procedure, patient preference, and cost are unknown. METHODS AND RESULTS We performed a randomized single-center trial in which 99 patients underwent transfemoral and 101 underwent transradial diagnostic cardiac catheterization. Quality of life was measured with the SF-36 and visual analog scales at baseline, 1 day, and 1 week. Patients were examined at 1 day and at 1 week after for complications. Costs were measured prospectively. One patient in the femoral group and 2 in the radial group crossed over to the alternative access site. There were no major access site complications. One patient in the transfemoral group had a minor stroke. Transradial catheterization significantly reduced median length of stay (3.6 vs 10.4 hours, P <.0001). Over the first day after the procedure, measures of bodily pain, back pain, and walking ability favored the transradial group (P <.05 for all comparisons). Over the week after the procedure, changes in role limitations caused by physical health, bodily pain, and back pain favored the transradial group (P <.05 for all comparisons). There was a strong patient preference for transradial catheterization as well (P <. 0001). Transradial catheterization led to significant reductions in bed, pharmacy, and total hospital costs ($2010 vs $2299, P <.0001). CONCLUSIONS Among patients undergoing diagnostic cardiac catheterization, transradial access leads to improved quality of life after the procedure, is strongly preferred by patients, and reduces hospital costs.
Collapse
|
Clinical Trial |
26 |
401 |
13
|
Tzikas A, Shakir S, Gafoor S, Omran H, Berti S, Santoro G, Kefer J, Landmesser U, Nielsen-Kudsk JE, Cruz-Gonzalez I, Sievert H, Tichelbäcker T, Kanagaratnam P, Nietlispach F, Aminian A, Kasch F, Freixa X, Danna P, Rezzaghi M, Vermeersch P, Stock F, Stolcova M, Costa M, Ibrahim R, Schillinger W, Meier B, Park JW. Left atrial appendage occlusion for stroke prevention in atrial fibrillation: multicentre experience with the AMPLATZER Cardiac Plug. EUROINTERVENTION 2016; 11:1170-1179. [PMID: 25604089 DOI: 10.4244/eijy15m01_06] [Citation(s) in RCA: 395] [Impact Index Per Article: 43.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
AIMS To investigate the safety, feasibility, and efficacy of left atrial appendage occlusion (LAAO) with the AMPLATZER Cardiac Plug (ACP) for stroke prevention in patients with atrial fibrillation (AF). METHODS AND RESULTS Data from consecutive patients treated in 22 centres were collected. A total of 1,047 patients were included in the study. Procedural success was 97.3%. There were 52 (4.97%) periprocedural major adverse events. Follow-up was complete in 1,001/1,019 (98.2%) of successfully implanted patients (average 13 months, total 1,349 patient-years). One-year all-cause mortality was 4.2%. No death at follow-up was reported as device-related. There were nine strokes (0.9%) and nine transient ischaemic attacks (0.9%) during follow-up. The annual rate of systemic thromboembolism was 2.3% (31/1,349 patient-years), which is a 59% risk reduction. There were 15 major bleedings (1.5%) during follow-up. The annual rate of major bleeding was 2.1% (28/1,349 patient-years), which is a 61% risk reduction. Patients with single LAAO on aspirin monotherapy or no therapy and longer follow-up had fewer cerebral and fewer bleeding events. CONCLUSIONS In this multicentre study, LAAO with the ACP showed high procedural success and a favourable outcome for the prevention of AF-related thromboembolism. Modification in antithrombotic therapy after LAAO may result in reduction of bleeding events.
Collapse
|
Multicenter Study |
9 |
395 |
14
|
Krumsdorf U, Ostermayer S, Billinger K, Trepels T, Zadan E, Horvath K, Sievert H. Incidence and clinical course of thrombus formation on atrial septal defect and patient foramen ovale closure devices in 1,000 consecutive patients. J Am Coll Cardiol 2004; 43:302-9. [PMID: 14736453 DOI: 10.1016/j.jacc.2003.10.030] [Citation(s) in RCA: 384] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
OBJECTIVES The purpose of this study was to investigate the incidence, morphology, and clinical course of thrombus formation after catheter closure of intra-atrial shunts. BACKGROUND Post-procedure detailed information about thrombotic material on different devices for transcatheter closure is missing. METHOD A total of 1,000 consecutive patients were investigated after patent foramen ovale (PFO) (n = 593) or atrial septal defect (ASD) (n = 407) closure. Transesophageal echocardiography (TEE) was scheduled after four weeks and six months. Additional TEEs were performed as clinically indicated. RESULTS Thrombus formation in the left atrium (n = 11), right atrium (n = 6), or both (n = 3) was found in 5 of the 407 (1.2%) ASD patients and in 15 of the 593 (2.5%) PFO patients (p = NS). The thrombus was diagnosed in 14 of 20 patients after four weeks and in 6 of 20 patients later on. The incidence was: 7.1% in the CardioSEAL device (NMT Medical, Boston, Massachusetts); 5.7% in the StarFLEX device (NMT Medical); 6.6% in the PFO-Star device (Applied Biometrics Inc., Burnsville, Minnesota); 3.6% in the ASDOS device (Dr. Ing, Osypka Corp., Grenzach-Wyhlen, Germany); 0.8% in the Helex device (W.L. Gore and Associates, Flagstaff, Arizona); and 0% in the Amplatzer device (AGA Medical Corp., Golden Valley, Minnesota). The difference between the Amplatzer device on one hand and the CardioSEAL device, the StarFLEX device, and the PFO-Star device on the other hand was significant (p < 0.05). A pre-thrombotic disorder as a possible cause of the thrombus was found in two PFO patients. Post-procedure atrial fibrillation (n = 4) and persistent atrial septal aneurysm (n = 4) had been found as significant predictors for thrombus formation (p < 0.05). In 17 of the 20 patients, the thrombus resolved under anticoagulation therapy with heparin or warfarin. In three patients, the thrombus was removed surgically. CONCLUSIONS The incidence of thrombus formation on closure devices is low. The thrombus usually resolves under anticoagulation therapy.
Collapse
|
Review |
21 |
384 |
15
|
Koreny M, Riedmüller E, Nikfardjam M, Siostrzonek P, Müllner M. Arterial puncture closing devices compared with standard manual compression after cardiac catheterization: systematic review and meta-analysis. JAMA 2004; 291:350-7. [PMID: 14734598 DOI: 10.1001/jama.291.3.350] [Citation(s) in RCA: 383] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
CONTEXT Arterial puncture closing devices (APCDs) were developed to replace standard compression at the puncture site and to shorten bed rest following percutaneous coronary intervention. OBJECTIVE To assess the safety and efficacy of APCDs (Angioseal, Vasoseal, Duett, Perclose, Techstar, Prostar) compared with standard manual compression in patients undergoing coronary angiography or percutaneous vascular interventions. DATA SOURCES A systematic literature search of MEDLINE (1966-January 2003), EMBASE (1989-January 2003), PASCAL (1996-January 2003), BIOSIS (1990-January 2003), and CINHAL (1982-January 2003) databases and the Cochrane Central Register of Controlled Trials for relevant articles in any language. STUDY SELECTION Included randomized controlled trials reporting vascular complications at the puncture site (hematoma, bleeding, arteriovenous fistula, pseudoaneurysm) and efficacy (time to hemostasis, time to ambulation, time to discharge from hospital). DATA EXTRACTION Two reviewers abstracted the data independently and in duplicate. Disagreements were resolved by discussion among at least 3 reviewers. The most important criteria were adequacy of allocation concealment, whether the analysis was according to the intention-to-treat principle, and if person assessing the outcome was blinded to intervention group. Random-effects models were used to pool the data. DATA SYNTHESIS Thirty trials met the selection criteria and included up to 4000 patients. When comparing any APCD with standard compression, the relative risk (RR) of groin hematoma was 1.14 (95% confidence interval [CI], 0.86-1.51; P =.35); bleeding, 1.48 (95% CI, 0.88-2.48; P =.14); developing an arteriovenous fistula, 0.83 (95% CI, 0.23-2.94; P =.77); and developing a pseudoaneurysm at the puncture site, 1.19 (95% CI, 0.75-1.88; P =.46). Time to hemostasis was shorter in the group with APCD compared with standard compression (mean difference, 17 minutes; range, 14-19 minutes), but there was a high degree of heterogeneity among studies. Only 2 studies explicitly reported allocation concealment, blinded outcome assessment, and intention-to-treat analysis. When limiting analyses to only trials that used explicit intention-to-treat approaches, APCDs were associated with a higher risk of hematoma (RR, 1.89; 95% CI, 1.13-3.15) and a higher risk of pseudoaneurysm (RR, 5.40; 95% CI, 1.21-24.5). CONCLUSIONS Based on this meta-analysis of 30 randomized trials, many of poor methodological quality, there is only marginal evidence that APCDs are effective and there is reason for concern that these devices may increase the risk of hematoma and pseudoaneurysm.
Collapse
|
Meta-Analysis |
21 |
383 |
16
|
Lee PH, Song JK, Kim JS, Heo R, Lee S, Kim DH, Song JM, Kang DH, Kwon SU, Kang DW, Lee D, Kwon HS, Yun SC, Sun BJ, Park JH, Lee JH, Jeong HS, Song HJ, Kim J, Park SJ. Cryptogenic Stroke and High-Risk Patent Foramen Ovale: The DEFENSE-PFO Trial. J Am Coll Cardiol 2018; 71:2335-2342. [PMID: 29544871 DOI: 10.1016/j.jacc.2018.02.046] [Citation(s) in RCA: 372] [Impact Index Per Article: 53.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2018] [Revised: 02/26/2018] [Accepted: 02/27/2018] [Indexed: 01/29/2023]
Abstract
BACKGROUND Recent reports showing the favorable role of patent foramen ovale (PFO) closure in patients with cryptogenic stroke have raised the issue of selecting optimal candidates. OBJECTIVES This study, DEFENSE-PFO (Device Closure Versus Medical Therapy for Cryptogenic Stroke Patients With High-Risk Patent Foramen Ovale), evaluated whether the benefits of PFO closure can be determined on the basis of the morphologic characteristics of the PFO, as evaluated by transesophageal echocardiography. METHODS Patients with cryptogenic stroke and high-risk PFO were divided between a transcatheter PFO closure and a medication-only group. High-risk PFO included PFO with atrial septal aneurysm, hypermobility (phasic septal excursion into either atrium ≥10 mm), or PFO size (maximum separation of the septum primum from the secundum) ≥2 mm. The primary endpoint was a composite of stroke, vascular death, or Thrombolysis In Myocardial Infarction-defined major bleeding during 2 years of follow-up. RESULTS From September 2011 until October 2017, 120 patients (mean age: 51.8 years) underwent randomization. PFO size, frequency of septal aneurysm (13.3% vs. 8.3%; p = 0.56), and hypermobility (45.0% vs. 46.7%; p > 0.99) were similar between the groups. All PFO closures were successful. The primary endpoint occurred exclusively in the medication-only group (6 of 60 patients; 2-year event rate: 12.9% [log-rank p = 0.013]; 2-year rate of ischemic stroke: 10.5% [p = 0.023]). The events in the medication-only group included ischemic stroke (n = 5), cerebral hemorrhage (n = 1), Thrombolysis In Myocardial Infarction-defined major bleeding (n = 2), and transient ischemic attack (n = 1). Nonfatal procedural complications included development of atrial fibrillation (n = 2), pericardial effusion (n = 1), and pseudoaneurysm (n = 1). CONCLUSIONS PFO closure in patients with high-risk PFO characteristics resulted in a lower rate of the primary endpoint as well as stroke recurrence. (Device Closure Versus Medical Therapy for Cryptogenic Stroke Patients With High-Risk Patent Foramen Ovale [DEFENSE-PFO]; NCT01550588).
Collapse
|
Multicenter Study |
7 |
372 |
17
|
Lock JE, Khalilullah M, Shrivastava S, Bahl V, Keane JF. Percutaneous catheter commissurotomy in rheumatic mitral stenosis. N Engl J Med 1985; 313:1515-8. [PMID: 4069160 DOI: 10.1056/nejm198512123132405] [Citation(s) in RCA: 367] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
We attempted percutaneous transcatheter-balloon mitral commissurotomy in eight children and young adults (9 to 23 years of age) with rheumatic mitral stenosis. The atrial septum was traversed by needle puncture, and an 8-mm angioplasty balloon was advanced over a guide wire. The atrial septal perforation was then dilated to allow passage of the valvuloplasty balloon catheter (18 to 25 mm) across the mitral annulus. Inflation of the transmitral balloon decreased the end-diastolic transmitral gradient temporarily in all patients (from 21.2 +/- 4.0 mm Hg [mean +/- S.D.] to 10.1 +/- 5.5 mm Hg; P less than 0.001). The immediate decrease in the gradient was associated with increases in cardiac output (from 3.8 +/- 1.0 to 4.9 +/- 1.3 liters per minute per square meter of body-surface area; P less than 0.01) and in the calculated mitral-valve-area index (from 0.73 +/- 0.29 to 1.34 +/- 0.32 cm2 per square meter; P less than 0.001). Murmur intensity diminished immediately after commissurotomy in all patients. The greatest reduction in pressure gradient (76 to 95 per cent) occurred when the largest balloon (inflated diameter, 25 mm) was used in the smallest patients (0.9 to 1.2 m2). The balloon commissurotomy produced minimal mitral regurgitation in only one child. Follow-up catheterization (at two to eight weeks) demonstrated persistence of hemodynamic improvement with evidence of partial restenosis in one patient. These early results indicate that balloon mitral commissurotomy can be a safe and effective treatment for children and young adults with rheumatic mitral stenosis.
Collapse
|
|
40 |
367 |
18
|
Kern MJ, Lerman A, Bech JW, De Bruyne B, Eeckhout E, Fearon WF, Higano ST, Lim MJ, Meuwissen M, Piek JJ, Pijls NHJ, Siebes M, Spaan JAE. Physiological assessment of coronary artery disease in the cardiac catheterization laboratory: a scientific statement from the American Heart Association Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology. Circulation 2006; 114:1321-41. [PMID: 16940193 DOI: 10.1161/circulationaha.106.177276] [Citation(s) in RCA: 357] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
With advances in technology, the physiological assessment of coronary artery disease in patients in the catheterization laboratory has become increasingly important in both clinical and research applications, but this assessment has evolved without standard nomenclature or techniques of data acquisition and measurement. Some questions regarding the interpretation, application, and outcome related to the results also remain unanswered. Accordingly, this consensus statement was designed to provide the background and evidence about physiological measurements and to describe standard methods for data acquisition and interpretation. The most common uses and support data from numerous clinical studies for the physiological assessment of coronary artery disease in the cardiac catheterization laboratory are reviewed. The goal of this statement is to provide a logical approach to the use of coronary physiological measurements in the catheterization lab to assist both clinicians and investigators in improving patient care.
Collapse
|
Journal Article |
19 |
357 |
19
|
Willson AB, Webb JG, Labounty TM, Achenbach S, Moss R, Wheeler M, Thompson C, Min JK, Gurvitch R, Norgaard BL, Hague CJ, Toggweiler S, Binder R, Freeman M, Poulter R, Poulsen S, Wood DA, Leipsic J. 3-Dimensional Aortic Annular Assessment by Multidetector Computed Tomography Predicts Moderate or Severe Paravalvular Regurgitation After Transcatheter Aortic Valve Replacement. J Am Coll Cardiol 2012; 59:1287-94. [PMID: 22365423 DOI: 10.1016/j.jacc.2011.12.015] [Citation(s) in RCA: 321] [Impact Index Per Article: 24.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2011] [Revised: 12/06/2011] [Accepted: 12/20/2011] [Indexed: 11/16/2022]
|
|
13 |
321 |
20
|
Sievert H, Lesh MD, Trepels T, Omran H, Bartorelli A, Della Bella P, Nakai T, Reisman M, DiMario C, Block P, Kramer P, Fleschenberg D, Krumsdorf U, Scherer D. Percutaneous left atrial appendage transcatheter occlusion to prevent stroke in high-risk patients with atrial fibrillation: early clinical experience. Circulation 2002; 105:1887-9. [PMID: 11997272 DOI: 10.1161/01.cir.0000015698.54752.6d] [Citation(s) in RCA: 306] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Thromboembolism due to atrial fibrillation (AF) is a frequent cause of stroke. More than 90% of thrombi in AF form in the left atrial appendage (LAA). Obliteration of the appendage may prevent embolic complications. METHODS AND RESULTS We evaluated the feasibility and safety of implanting a novel device for percutaneous left atrial appendage transcatheter occlusion (PLAATO). LAA occlusion using the PLAATO system was attempted in 15 patients with chronic AF at high risk for stroke, who are poor candidates for long-term warfarin therapy. The implant consists of a self-expanding nitinol cage covered with a polymeric membrane (ePTFE). The LAA was successfully occluded in 15/15 patients (100%). Angiography and transesophageal echocardiography (TEE) during the procedure showed that the device was well-seated in all patients and that there was no evidence of perforation, device embolization, or interference with surrounding structures. In 1 patient, the first procedure was complicated by a hemopericardium, which occurred during LAA access. A second attempt 30 days later was successful with no untoward sequela. No other complications occurred. At 1-month follow-up, chest fluoroscopy and TEE revealed continued stable implant position with smooth atrial-facing surface and no evidence of thrombus. CONCLUSIONS Thus, transcatheter closure of the LAA is feasible in humans. This novel implant technology may be appropriate for patients with AF who are not suitable candidates for anticoagulation therapy. Further trials are needed to show the long-term safety and its efficacy in reducing stroke.
Collapse
|
Clinical Trial |
23 |
306 |
21
|
Armsby LR, Keane JF, Sherwood MC, Forbess JM, Perry SB, Lock JE. Management of coronary artery fistulae. Patient selection and results of transcatheter closure. J Am Coll Cardiol 2002; 39:1026-32. [PMID: 11897446 DOI: 10.1016/s0735-1097(02)01742-4] [Citation(s) in RCA: 299] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVES We report short-term findings in 33 patients after transcatheter closure (TCC) of coronary artery fistulae (CAF) and compare our results with those reported in the recent transcatheter and surgical literature. BACKGROUND Transcatheter closure of CAF has been advocated as a minimally invasive alternative to surgery. METHODS We reviewed all patients presenting with significant CAF between January 1988 and August 2000. Those with additional complex cardiac disease requiring surgical management were excluded. RESULTS Of 39 patients considered for TCC, occlusion devices were placed in 33 patients (85%) at 35 procedures and included coils in 28, umbrella devices in 6 and a Grifka vascular occlusion device in 1. Post-deployment angiograms demonstrated complete occlusion in 19, trace in 11, or small residual flow in 5. Follow-up echocardiograms (median, 2.8 years) in 27 patients showed no flow in 22 or small residual flow in 5. Of the 6 patients without follow-up imaging, immediate post-deployment angiograms showed complete occlusion in 5 or small residual flow in 1. Thus, complete occlusion was accomplished in 27 patients (82%). Early complications included transient ST-T wave changes in 5, transient arrhythmias in 4 and single instances of distal coronary artery spasm, fistula dissection and unretrieved coil embolization. There were no deaths or long-term morbidity. Device placement was not attempted in 6 patients (15%), because of multiple fistula drainage sites in 4, extreme vessel tortuosity in 1 and an intracardiac hemangioma in 1. CONCLUSIONS A comparison of our results with those in the recent transcatheter and surgical literature shows similar early effectiveness, morbidity and mortality. From data available, TCC of CAF is an acceptable alternative to surgery in most patients.
Collapse
|
Comparative Study |
23 |
299 |
22
|
Waksman R, Di Mario C, Torguson R, Ali ZA, Singh V, Skinner WH, Artis AK, Cate TT, Powers E, Kim C, Regar E, Wong SC, Lewis S, Wykrzykowska J, Dube S, Kazziha S, van der Ent M, Shah P, Craig PE, Zou Q, Kolm P, Brewer HB, Garcia-Garcia HM. Identification of patients and plaques vulnerable to future coronary events with near-infrared spectroscopy intravascular ultrasound imaging: a prospective, cohort study. Lancet 2019; 394:1629-1637. [PMID: 31570255 DOI: 10.1016/s0140-6736(19)31794-5] [Citation(s) in RCA: 295] [Impact Index Per Article: 49.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 07/17/2019] [Accepted: 07/22/2019] [Indexed: 12/13/2022]
Abstract
BACKGROUND Near-infrared spectroscopy (NIRS) intravascular ultrasound imaging can detect lipid-rich plaques (LRPs). LRPs are associated with acute coronary syndromes or myocardial infarction, which can result in revascularisation or cardiac death. In this study, we aimed to establish the relationship between LRPs detected by NIRS-intravascular ultrasound imaging at unstented sites and subsequent coronary events from new culprit lesions. METHODS In this prospective, cohort study (LRP), patients from 44 medical centres were enrolled in Italy, Latvia, Netherlands, Slovakia, UK, and the USA. Patients with suspected coronary artery disease who underwent cardiac catheterisation with possible ad hoc percutaneous coronary intervention were eligible to be enrolled. Enrolled patients underwent scanning of non-culprit segments using NIRS-intravascular ultrasound imaging. The study had two hierarchal primary hypotheses, patient and plaque, each testing the association between maximum 4 mm Lipid Core Burden Index (maxLCBI4mm) and non-culprit major adverse cardiovascular events (NC-MACE). Enrolled patients with large LRPs (≥250 maxLCBI4mm) and a randomly selected half of patients with small LRPs (<250 maxLCBI4mm) were followed up for 24 months. This study is registered with ClinicalTrials.gov, NCT02033694. FINDINGS Between Feb 21, 2014, and March 30, 2016, 1563 patients were enrolled. NIRS-intravascular ultrasound device-related events were seen in six (0·4%) patients. 1271 patients (mean age 64 years, SD 10, 883 [69%] men, 388 [31%]women) with analysable maxLCBI4mm were allocated to follow-up. The 2-year cumulative incidence of NC-MACE was 9% (n=103). Both hierarchical primary hypotheses were met. On a patient level, the unadjusted hazard ratio (HR) for NC-MACE was 1·21 (95% CI 1·09-1·35; p=0·0004) for each 100-unit increase maxLCBI4mm) and adjusted HR 1·18 (1·05-1·32; p=0·0043). In patients with a maxLCBI4mm more than 400, the unadjusted HR for NC-MACE was 2·18 (1·48-3·22; p<0·0001) and adjusted HR was 1·89 (1·26-2·83; p=0·0021). At the plaque level, the unadjusted HR was 1·45 (1·30-1·60; p<0·0001) for each 100-unit increase in maxLCBI4mm. For segments with a maxLCBI4mm more than 400, the unadjusted HR for NC-MACE was 4·22 (2·39-7·45; p<0·0001) and adjusted HR was 3·39 (1·85-6·20; p<0·0001). INTERPRETATION NIRS imaging of non-obstructive territories in patients undergoing cardiac catheterisation and possible percutaneous coronary intervention was safe and can aid in identifying patients and segments at higher risk for subsequent NC-MACE. NIRS-intravascular ultrasound imaging adds to the armamentarium as the first diagnostic tool able to detect vulnerable patients and plaques in clinical practice. FUNDING Infraredx.
Collapse
|
Clinical Trial |
6 |
295 |
23
|
Nickenig G, Weber M, Lurz P, von Bardeleben RS, Sitges M, Sorajja P, Hausleiter J, Denti P, Trochu JN, Näbauer M, Dahou A, Hahn RT. Transcatheter edge-to-edge repair for reduction of tricuspid regurgitation: 6-month outcomes of the TRILUMINATE single-arm study. Lancet 2019; 394:2002-2011. [PMID: 31708188 DOI: 10.1016/s0140-6736(19)32600-5] [Citation(s) in RCA: 295] [Impact Index Per Article: 49.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 09/09/2019] [Accepted: 09/16/2019] [Indexed: 01/02/2023]
Abstract
BACKGROUND Tricuspid regurgitation is a prevalent disease associated with high morbidity and mortality, with few treatment options. The aim of the TRILUMINATE trial is to evaluate the safety and effectiveness of TriClip, a minimally invasive transcatheter tricuspid valve repair system, for reducing tricuspid regurgitation. METHODS The TRILUMINATE trial is a prospective, multicentre, single-arm study in 21 sites in Europe and the USA. Patients with moderate or greater triscuspid regurgitation, New York Heart Association class II or higher, and who were adequately treated per applicable standards were eligible for enrolment. Patients were excluded if they had systolic pulmonary artery pressure of more than 60 mm Hg, a previous tricuspid valve procedure, or a cardiovascular implantable electronic device that would inhibit TriClip placement. Participants were treated using a clip-based edge-to-edge repair technique with the TriClip tricuspid valve repair system. Tricuspid regurgitation was graded using a five-class grading scheme (mild, moderate, severe, massive, and torrential) that expanded on the standard American Society of Echocardiography grading scheme. The primary efficacy endpoint was a reduction in tricuspid regurgitation severity by at least one grade at 30 days post procedure, with a performance goal of 35%, analysed in all patients who had an attempted tricuspid valve repair procedure upon femoral vein puncture. The primary safety endpoint was a composite of major adverse events at 6 months, with a performance goal of 39%. Patients were excluded from the primary safety analysis if they did not reach 6-month follow-up and did not have a major adverse event during previous follow-ups. The trial has completed enrolment and follow-up is ongoing; it is registered with ClinicalTrials.gov, number NCT03227757. FINDINGS Between Aug 1, 2017, and Nov 29, 2018, 85 patients (mean age 77·8 years [SD 7·9]; 56 [66%] women) were enrolled and underwent successful TriClip implantation. Tricuspid regurgitation severity was reduced by at least one grade at 30 days in 71 (86%) of 83 patients who had available echocardiogram data and imaging. The one-sided lower 97·5% confidence limit was 76%, which was greater than the prespecified performance goal of 35% (p<0·0001). One patient withdrew before 6-month follow-up without having had a major adverse event and was excluded from analysis of the primary safety endpoint. At 6 months, three (4%) of 84 patients experienced a major adverse event, which was less than the prespecified performance goal of 39% (p<0·0001). Single leaflet attachment occurred in five (7%) of 72 patients. No periprocedural deaths, conversions to surgery, device embolisations, myocardial infarctions, or strokes occurred. At 6 months, all-cause mortality had occurred in four (5%) of 84 patients. INTERPRETATION The TriClip system appears to be safe and effective at reducing tricuspid regurgitation by at least one grade. This reduction could translate to significant clinical improvement at 6 months post procedure. FUNDING Abbott.
Collapse
|
Multicenter Study |
6 |
295 |
24
|
Brar SS, Aharonian V, Mansukhani P, Moore N, Shen AYJ, Jorgensen M, Dua A, Short L, Kane K. Haemodynamic-guided fluid administration for the prevention of contrast-induced acute kidney injury: the POSEIDON randomised controlled trial. Lancet 2014; 383:1814-23. [PMID: 24856027 DOI: 10.1016/s0140-6736(14)60689-9] [Citation(s) in RCA: 284] [Impact Index Per Article: 25.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND The administration of intravenous fluid remains the cornerstone treatment for the prevention of contrast-induced acute kidney injury. However, no well-defined protocols exist to guide fluid administration in this treatment. We aimed to establish the efficacy of a new fluid protocol to prevent contrast-induced acute kidney injury. METHODS In this randomised, parallel-group, comparator-controlled, single-blind phase 3 trial, we assessed the efficacy of a new fluid protocol based on the left ventricular end-diastolic pressure for the prevention of contrast-induced acute kidney injury in patients undergoing cardiac catheterisation. The primary outcome was the occurrence of contrast-induced acute kidney injury, which was defined as a greater than 25% or greater than 0·5 mg/dL increase in serum creatinine concentration. Between Oct 10, 2010, and July 17, 2012, 396 patients aged 18 years or older undergoing cardiac catheterisation with an estimated glomerular filtration rate of 60 mL/min per 1·73 m(2) or less and one or more of several risk factors (diabetes mellitus, history of congestive heart failure, hypertension, or age older than 75 years) were randomly allocated in a 1:1 ratio to left ventricular end-diastolic pressure-guided volume expansion (n=196) or the control group (n=200) who received a standard fluid administration protocol. Four computer-generated concealed randomisation schedules, each with permuted block sizes of 4, were used for randomisation, and participants were allocated to the next sequential randomisation number by sealed opaque envelopes. Patients and laboratory personnel were masked to treatment assignment, but the physicians who did the procedures were not masked. Both groups received intravenous 0·9% sodium chloride at 3 mL/kg for 1 h before cardiac catheterisation. Analyses were by intention to treat. Adverse events were assessed at 30 days and 6 months and all such events were classified by staff who were masked to treatment assignment. This trial is registered with ClinicalTrials.gov, number NCT01218828. FINDINGS Contrast-induced acute kidney injury occurred less frequently in patients in the left ventricular end-diastolic pressure-guided group (6·7% [12/178]) than in the control group (16·3% [28/172]; relative risk 0·41, 95% CI 0·22-0·79; p=0·005). Hydration treatment was terminated prematurely because of shortness of breath in three patients in each group. INTERPRETATION Left ventricular end-diastolic pressure-guided fluid administration seems to be safe and effective in preventing contrast-induced acute kidney injury in patients undergoing cardiac catheterisation. FUNDING Kaiser Permanente Southern California regional research committee grant.
Collapse
|
Clinical Trial, Phase III |
11 |
284 |
25
|
Palacios I, Block PC, Brandi S, Blanco P, Casal H, Pulido JI, Munoz S, D'Empaire G, Ortega MA, Jacobs M. Percutaneous balloon valvotomy for patients with severe mitral stenosis. Circulation 1987; 75:778-84. [PMID: 3829341 DOI: 10.1161/01.cir.75.4.778] [Citation(s) in RCA: 277] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Thirty-five patients with severe mitral stenosis underwent percutaneous mitral valvotomy (PMV). There were 29 female and six male patients (mean age 49 +/- 3 years, range 13 to 87). After transseptal left heart catheterization, PMV was performed with either a single- (20 patients) or double- (14 patients) balloon dilating catheter. Hemodynamic and left ventriculographic findings were evaluated before and after PMV. There was one death. Mitral regurgitation developed or increased in severity in 15 patients (43%). One patient developed complete heart block requiring a permanent pacemaker. PMV resulted in a significant decrease in mitral gradient from 18 +/- 1 to 7 +/- 1 mm Hg (p less than .0001) and a significant increase in both cardiac output from 3.9 +/- 0.2 to 4.6 +/- 0.2 liters/min (p less than .001) and in mitral valve area from 0.8 +/- 0.1 to 1.7 +/- 0.2 cm2 (p less than .0001) Effective balloon dilating diameter per square meter of body surface area correlated significantly with the decrease in mitral gradient but did not correlate with the degree of mitral regurgitation. There was no correlation of age, prior mitral commissurotomy or mitral calcification with hemodynamic results. PMV is an effective nonsurgical procedure for patients with mitral stenosis, including those with pliable valves, those with previous commissurotomy, and even those with mitral calcification.
Collapse
|
Comparative Study |
38 |
277 |