1
|
Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J, Galante JO. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am 1998; 80:1447-58. [PMID: 9801213 DOI: 10.2106/00004623-199810000-00006] [Citation(s) in RCA: 343] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
UNLABELLED There is an increasing recognition that, in the long term, total joint replacement may be associated with adverse local and remote tissue responses that are mediated by the degradation products of prosthetic materials. Particular interest has centered on the metal-degradation products of total joint replacements because of the known toxicities of the metal elements that make up the alloys used in the implants. We measured the concentrations of titanium, aluminum, cobalt, and chromium in the serum and the concentration of chromium in the urine of seventy-five patients during a three-year prospective, longitudinal study. Twenty patients had had a so-called hybrid total hip replacement (insertion of a modular cobalt-alloy femoral stem and head with cement and a titanium acetabular cup without cement), fifteen had had insertion of an extensively porous-coated cobalt-alloy stem with a cobalt-alloy head and a titanium-alloy socket without cement, and twenty had had insertion of a proximally porous-coated titanium-alloy stem with a cobalt-alloy head and a titanium socket without cement. The remaining twenty patients did not have an implant and served as controls. The results of our study showed that, thirty-six months postoperatively, patients who have a well functioning prosthesis with components containing titanium have as much as a threefold increase in the concentration of titanium in the serum and those who have a well functioning prosthesis with cobalt-alloy components have as much as a fivefold and an eightfold increase in the concentrations of chromium in the serum and urine, respectively. The predominant source of the disseminated chromium-degradation products is probably the modular head-neck junction and may be a function of the geometry of the coupling. Passive dissolution of extensively porous-coated cobalt-alloy stems was not found to be a dominant mode of metal release. CLINICAL RELEVANCE Increased concentrations of circulating metal-degradation products derived from orthopaedic implants may have deleterious biological effects over the long term that warrant investigation. This is a particularly timely concern because of recent clinical trends, including the reintroduction of metal-on-metal bearing surfaces and the increasing popularity of extensively porous-coated devices with large surface areas of exposed metal. Accurate monitoring of the concentrations of metal in the serum and urine after total hip replacement also can provide insights into the mechanisms of metal release. Our findings suggest that fretting corrosion at the head-neck coupling is an important source of metal release that can lead to increased concentrations of chromium in the serum. Determinations of the concentrations of metal in the serum and urine may be useful in the diagnosis of patients who are symptomatic after a total joint replacement as increased levels are indicative of at least one mode of mechanical dysfunction (for example, fretting corrosion) of the device.
Collapse
|
|
27 |
343 |
2
|
Jacobs JJ, Skipor AK, Doorn PF, Campbell P, Schmalzried TP, Black J, Amstutz HC. Cobalt and chromium concentrations in patients with metal on metal total hip replacements. Clin Orthop Relat Res 1996:S256-63. [PMID: 8769339 DOI: 10.1097/00003086-199608001-00022] [Citation(s) in RCA: 264] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
There has been a resurgence of interest in the use of metal on metal bearings in total hip arthroplasty. Although the use of metal on metal bearing couples would eliminate or substantially reduce particulate polyethylene generation (depending on the presence or absence of polyethylene in the implant system), there is concern about the potential for increased particulate and ionic metal generation in comparison with polyethylene on metal bearings. These metallic degradation products may be transported away from the implant site and distributed systemically. Chromium concentrations in the serum and urine and cobalt concentrations in the serum were measured in subjects with cobalt chromium alloy metal on metal total hip replacements and in controls without implants. Eight subjects with long term (> 20 years) McKee-Farrar total hip replacements had 9-fold elevations in serum chromium, 35-fold elevations in urine chromium, and at least 3-fold elevations in serum cobalt concentrations in comparison with controls. Six subjects with short term (< 2 years) metal on metal surface replacement arthroplasties had 3-fold elevations in serum chromium, 4-fold elevations in urine chromium, and 4-fold elevations in serum cobalt concentrations in comparison with subjects with McKee-Farrar implants. Although the toxicologic importance of these trace metal elevations has not been established, serum and urine metal concentrations may be useful markers for the tribologic performance of metal on metal bearings.
Collapse
|
|
29 |
264 |
3
|
Abstract
There is increasing evidence to support a role for both the amyloid beta-protein precursor (AbetaPP) and its proteolytic fragment, amyloid beta (Abeta), in metal ion homeostasis. Furthermore, metal ions such as zinc and copper can interact with both AbetaPP and Abeta to potentiate Alzheimer's disease by participating in the aggregation of these normal cellular proteins and in the generation of reactive oxygen species. In addition, metal ions may interact on several other AD-related pathways, including those involved in neurofibrillary tangle formation, secretase cleavage of AbetaPP and proteolytic degradation of Abeta. As such, a dysregulation of metal ion homeostasis, as occurs with both aging and in AD, may foster an environment that can both precipitate and accelerate degenerative conditions such as AD. This offers a broad biochemical front for novel therapeutic interventions.
Collapse
|
|
19 |
243 |
4
|
Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R. Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am 2003; 85:2168-73. [PMID: 14630848 DOI: 10.2106/00004623-200311000-00017] [Citation(s) in RCA: 215] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Systemic cobalt dissemination from the Metasul Co-28Cr-6Mo-0.2C metal-on-metal total hip prosthesis has been demonstrated in the first year after implantation. The aim of this prospective study was to monitor the serum cobalt concentrations in patients during the first five years after total hip arthroplasty with a metal-on-metal articulation. METHODS A total hip arthroplasty was performed without cement in 100 consecutive patients who had either unilateral osteoarthritis or unilateral osteonecrosis. Fifty patients were randomized to be treated with a metal-on-metal articulation, and fifty patients, with a ceramic-on-polyethylene bearing. The femoral stem was made of a Ti-6Al-7Nb alloy, and the threaded acetabular cup was made of commercially pure titanium. Blood samples were taken before the operation and at multiple time-points for five years after the operation. Serum cobalt concentrations were measured with use of atomic absorption spectrometry. RESULTS In the metal-on-metal group, the median serum cobalt concentration was 1 micro g/L at one year after surgery and 0.7 micro g/L at five years. The median of the serum cobalt concentrations measured from three to twelve months did not differ from the median of subsequent measurements, with the numbers available. The median serum cobalt level in the control group of patients treated with the ceramic-on-polyethylene articulation was below the detection limit at all time-points. CONCLUSIONS Systemic cobalt release from Metasul metal-on-metal articulations was demonstrated throughout the five-year study period. The median serum cobalt concentrations were found to be slightly above the detection limit and remained in a constant range. The serum cobalt concentrations did not reflect a so-called run-in wear period of the metal-on-metal articulations.
Collapse
|
Clinical Trial |
22 |
215 |
5
|
Coleman RF, Herrington J, Scales JT. Concentration of wear products in hair, blood, and urine after total hip replacement. BRITISH MEDICAL JOURNAL 1973; 1:527-9. [PMID: 4692678 PMCID: PMC1588720 DOI: 10.1136/bmj.1.5852.527] [Citation(s) in RCA: 209] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Raised levels of cobalt and chromium are found in the blood and urine of patients with metallic total hip replacements. When one of the hip components is made of polyethylene much less metal seems to be released from the joint. The long-term effects of the accumulation of chromium in the body need to be studied further.
Collapse
|
research-article |
52 |
209 |
6
|
Lhotka C, Szekeres T, Steffan I, Zhuber K, Zweymüller K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J Orthop Res 2003; 21:189-95. [PMID: 12568948 DOI: 10.1016/s0736-0266(02)00152-3] [Citation(s) in RCA: 188] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Metal-on-metal total hip prostheses will produce a certain amount of wear debris. This results in increased whole-blood metal levels, which may cause adverse effects. It is not known to what extent the problem has been overcome by advances in alloy technology. METHODS In 259 patients who with total hip replacement, blood cobalt and chromium concentrations were measured with atomic absorption spectrophotometry over a period of four years after arthroplasty. Of the patients enrolled in the study, 131 had been managed with a METASUL cobalt-chromium alloy metal-on-metal bearing combination, while 128 had been given a SIKOMET-SM21 cobalt-chromium alloy metal-on-metal combination. The control group consisted of 31 age- and gender-matched subjects. RESULTS Compared with the controls, all the patients had higher cobalt and chromium levels. Cobalt concentrations were up to 50 times higher, while chromium concentrations were up to 100 times higher. CONCLUSIONS Both systems showed evidence, in the whole-blood samples, of wear debris production by the implants. Therefore, patients managed with metal-on-metal bearing combinations should be carefully monitored in order to ensure that any local or systemic complications are detected early on.
Collapse
|
Comparative Study |
22 |
188 |
7
|
Ziaee H, Daniel J, Datta AK, Blunt S, McMinn DJW. Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study. ACTA ACUST UNITED AC 2007; 89:301-5. [PMID: 17356138 DOI: 10.1302/0301-620x.89b3.18520] [Citation(s) in RCA: 157] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Metal-on-metal bearings are being increasingly used in young patients. The potential adverse effects of systemic metal ion elevation are the subject of ongoing investigation. The purpose of this study was to investigate whether cobalt and chromium ions cross the placenta of pregnant women with a metal-on-metal hip resurfacing and reach the developing fetus. Whole blood levels were estimated using high-resolution inductively-coupled plasma mass spectrometry. Our findings showed that cobalt and chromium are able to cross the placenta in the study patients with metal-on-metal hip resurfacings and in control subjects without any metal implants. In the study group the mean concentrations of cobalt and chromium in the maternal blood were 1.39 microg/l (0.55 to 2.55) and 1.28 microg/l (0.52 to 2.39), respectively. The mean umbilical cord blood concentrations of cobalt and chromium were comparatively lower, at 0.839 microg/l (0.42 to 1.75) and 0.378 microg/l (0.14 to 1.03), respectively, and this difference was significant with respect to chromium (p < 0.05). In the control group, the mean concentrations of cobalt and chromium in the maternal blood were 0.341 microg/l (0.18 to 0.54) and 0.199 microg/l (0.12 to 0.33), and in the umbilical cord blood they were 0.336 microg/l (0.17 to 0.5) and 0.194 microg/l (0.11 to 0.56), respectively. The differences between the maternal and umbilical cord blood levels in the controls were marginal, and not statistically significant (p > 0.05). The mean cord blood level of cobalt in the study patients was significantly greater than that in the control group (p < 0.01). Although the mean umbilical cord blood chromium level was nearly twice as high in the study patients (0.378 microg/l) as in the controls (0.1934 microg/l), this difference was not statistically significant. (p > 0.05) The transplacental transfer rate was in excess of 95% in the controls for both metals, but only 29% for chromium and 60% for cobalt in study patients, suggesting that the placenta exerts a modulatory effect on the rate of metal ion transfer.
Collapse
|
Journal Article |
18 |
157 |
8
|
Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty 2004; 19:78-83. [PMID: 15578558 DOI: 10.1016/j.arth.2004.09.010] [Citation(s) in RCA: 151] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
A prospective study was performed to investigate changes in metal levels and chromosome aberrations in patients within 2 years of receiving metal-on-metal hip arthroplasties. There was a statistically significant increase of cobalt and chromium concentrations, with a small increase in molybdenum, in whole blood at 6, 12, and 24 months after surgery. There was also a statistically significant increase of both chromosome translocations and aneuploidy in peripheral blood lymphocytes at 6, 12, and 24 months after surgery. The changes were generally progressive with time, but the change in aneuploidy was much greater than in chromosome translocations. No statistically significant correlations were found in secondary analyses between chromosome translocation indices and cobalt or chromium concentration in whole blood. Although the clinical consequences of these changes, if any, are unknown, future epidemiological studies could usefully include direct comparisons of patients with implants of different composition.
Collapse
|
|
21 |
151 |
9
|
Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, Veronesi CA, Baldini N, Giunti A. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2003; 63:467-74. [PMID: 12209889 DOI: 10.1002/jbm.10299] [Citation(s) in RCA: 150] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Polyethylene (PE) wear has been shown to be a problem in long-term joint replacement using metal-on-PE bearing. The use of metallic heads articulating with metallic cups could solve this problem: success will be enhanced if wear and corrosion of the articulating surfaces are maintained at a low level. New models with metal-on-metal bearing have been proposed, to be used mainly for young subjects: such coupling seems to have a reduced release, but it is unclear yet if the medium-term corrosion rate is really negligible or, on the contrary, it is significantly higher than in the metal-on-PE bearing. Aim of our study was the comparison of ion release in the serum of two groups of patients who had the same type of stable cementless prosthesis, but different bearing: twenty-six patients with metal-on-metal (Group A) and fifteen patients with metal-on-PE bearing (Group B) were examined. The follow-up was 14-38 months for group A and 18-34 months for group B. The serum concentration of chromium (Cr), cobalt (Co) and molybdenum (Mo) was measured. Twenty-two patients before surgery were used for comparison (Group C). The reference values were obtained from a population of twenty-two healthy subjects (Group D). Our findings indicate that metal-on-metal bearings produce a significantly higher systemic release of cobalt and chromium (ng/ml) when compared with levels found in metal-on-PE, pre-surgery and reference groups. Such a high release should induce to improve the bearing materials or, at least, to study the biologic fate of metal ions and consequently their long-term effects. In such a way a risk-to-benefit ratio for the patient could be established.
Collapse
|
Comparative Study |
22 |
150 |
10
|
Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R. Elevated serum cobalt with metal-on-metal articulating surfaces. THE JOURNAL OF BONE AND JOINT SURGERY. BRITISH VOLUME 1997; 79:316-21. [PMID: 9119865 DOI: 10.1302/0301-620x.79b2.7326] [Citation(s) in RCA: 135] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
We determined serum cobalt levels in 55 patients by atomic absorption spectrophotometry before and after implantation of uncemented total hip arthroplasties. In a randomised, prospective trial 27 wrought Co-28Cr-6Mo-0.2C metal-on-metal articulations were compared with 28 ceramic-on-polyethylene hips which did not contain cobalt. Other sources of iatrogenic cobalt loading were excluded. The metal-on-metal group produced detectable serum cobalt levels (median 1.1 microg/l after one year) which were significantly different (p < 0.0001) from those of the ceramic-on-polyethylene control group (median below detection limit of 0.3 microg/l after one year). Our findings indicate that metal-on-metal bearings generate some systemic release of cobalt.
Collapse
|
Clinical Trial |
28 |
135 |
11
|
Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. ACTA ACUST UNITED AC 2007; 89:441-8. [PMID: 17463109 DOI: 10.1302/0301-620x.89b4.18054] [Citation(s) in RCA: 133] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We evaluated the concentrations of chromium and cobalt ions in blood after metal-on-metal surface replacement arthroplasty using a wrought-forged, high carbon content chromium-cobalt alloy implant in 64 patients. At one year, mean whole blood ion levels were 1.61 μg/L (0.4 to 5.5) for chromium and 0.67 μg/L (0.23 to 2.09) for cobalt. The pre-operative ion levels, component size, female gender and the inclination of the acetabular component were inversely proportional to the values of chromium and/or cobalt ions at one year postoperatively. Other factors, such as age and level of activity, did not correlate with the levels of metal ions. We found that the levels of the ions in the serum were 1.39 and 1.37 times higher for chromium and cobalt respectively than those in the whole blood. The levels of metal ions obtained may be specific to the hip resurfacing implant and reflect its manufacturing process.
Collapse
|
|
18 |
133 |
12
|
Meltzer HM, Brantsaeter AL, Borch-Iohnsen B, Ellingsen DG, Alexander J, Thomassen Y, Stigum H, Ydersbond TA. Low iron stores are related to higher blood concentrations of manganese, cobalt and cadmium in non-smoking, Norwegian women in the HUNT 2 study. ENVIRONMENTAL RESEARCH 2010; 110:497-504. [PMID: 20381026 DOI: 10.1016/j.envres.2010.03.006] [Citation(s) in RCA: 128] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2009] [Revised: 02/09/2010] [Accepted: 03/17/2010] [Indexed: 05/20/2023]
Abstract
Low iron (Fe) stores may influence absorption or transport of divalent metals in blood. To obtain more knowledge about such associations, the divalent metal ions cadmium (Cd), manganese (Mn), cobalt (Co), copper (Cu), zinc (Zn) and lead (Pb) and parameters of Fe metabolism (serum ferritin, haemoglobin (Hb) and transferrin) were investigated in 448 healthy, menstruating non-smoking women, age 20-55 years (mean 38 years), participating in the Norwegian HUNT 2 study. The study population was stratified for serum ferritin: 257 were iron-depleted (serum ferritin < 12 microg/L) and 84 had iron deficiency anaemia (serum ferritin < 12 microg/L and Hb < 120 g/L). The low ferritin group had increased blood concentrations of Mn, Co and Cd but normal concentrations of Cu, Zn and Pb. In multiple regression models, ferritin emerged as the main determinant of Mn, Co and Cd (p < 0.001), while no significant associations with Cu, Zn and Pb were found. Adjusted r(2) for the models were 0.28, 0.48 and 0.34, respectively. Strong positive associations between blood concentrations of Mn, Co and Cd were observed, also when controlled for their common association with ferritin. Apart from these associations, the models showed no significant interactions between the six divalent metals studied. Very mild anaemia (110 < or = Hb < 120 g/L) did not seem to have any effect independent of low ferritin. Approximately 26% of the women with iron deficiency anaemia had high concentrations of all of Mn, Co and Cd as opposed to 2.3% of iron-replete subjects. The results confirm that low serum ferritin may have an impact on body kinetics of certain divalent metal ions, but not all. Only a fraction of women with low iron status exhibited an increased blood concentration of divalent metals, providing indication of complexities in the body's handling of these metals.
Collapse
|
|
15 |
128 |
13
|
Back DL, Young DA, Shimmin AJ. How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? Clin Orthop Relat Res 2005; 438:177-81. [PMID: 16131888 DOI: 10.1097/01.blo.0000166901.84323.5d] [Citation(s) in RCA: 127] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
We prospectively monitored changes in serum cobalt and chromium levels after a new generation metal-on-metal hip resurfacing and the affect on renal function. Levels were measured using inductively coupled plasma mass spectrometry and atomic absorption spectrometry, preoperatively then sequentially at 3, 6, 9, 12, and 24 months. For serum cobalt, there was an initial increase to a peak level at 6 months, followed by a gradual decline during the next 15 months. A similar trend was observed in serum chromium, although the peak level occurred slightly later, at 9 months. There was no adverse affect on renal function during the 2-year study period. All implants were functioning well, with no radiographic evidence of loosening. These levels will continue to be monitored to establish when minimum metal ion levels are reached.
Collapse
|
|
20 |
127 |
14
|
Grübl A, Marker M, Brodner W, Giurea A, Heinze G, Meisinger V, Zehetgruber H, Kotz R. Long-term follow-up of metal-on-metal total hip replacement. J Orthop Res 2007; 25:841-8. [PMID: 17405158 DOI: 10.1002/jor.20381] [Citation(s) in RCA: 125] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Metal-on-metal articulations were reintroduced to reduce polyethylene particle-induced osteolysis. Elevated serum metal levels have been detected at short- and intermediate-term follow-up. There is little knowledge about long-term effects of increased ionic metal generation. Our study was undertaken to provide information about long-term survival, clinical outcome, radiographic appearance, and serum metal concentrations after a minimum 10 years follow-up with a metal-on-metal hip prosthesis: 105 cementless primary total hip prostheses with metal-on-metal articulating surfaces were implanted in 98 patients with a mean age of 56 years. Clinical data, radiographs, and blood samples were obtained at a follow-up visit 10 years after implantation. Serum cobalt and chromium levels were determined with use of atomic absorption spectrometry. General laboratory analyses included a full blood count and kidney function parameters. The Harris score was 92 points and the UCLA score 6 points after 10 years. Small osteolytic lesions and radiolucent lines were found in Gruen's zones 1, 7, 8, and 14. The probability of survival was 98.6%. The median serum cobalt concentration of the 22 patients with their hip replacement as the only source of cobalt was 0.75 microg/L (range, 0.3-50.1 microg/L). No patient was diagnosed with renal insufficiency during the study period. Five patients were diagnosed with a malignancy between surgery and the follow-up. We do not have evidence of an increased rate of primary malignancies nor could we detect renal failure in our study group. Serum metal levels did not differ from short- and intermediate term follow-up values.
Collapse
|
|
18 |
125 |
15
|
Heath JC, Freeman MA, Swanson SA. Carcinogenic properties of wear particles from prostheses made in cobalt-chromium alloy. Lancet 1971; 1:564-6. [PMID: 4100901 DOI: 10.1016/s0140-6736(71)91162-7] [Citation(s) in RCA: 124] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
|
54 |
124 |
16
|
Schaffer AW, Pilger A, Engelhardt C, Zweymueller K, Ruediger HW. Increased blood cobalt and chromium after total hip replacement. JOURNAL OF TOXICOLOGY. CLINICAL TOXICOLOGY 2000; 37:839-44. [PMID: 10630267 DOI: 10.1081/clt-100102463] [Citation(s) in RCA: 122] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To determine metal concentrations in blood and urine of patients who received cobalt-chromium-alloy metal on metal hip implants. METHODS Cobalt and chromium were determined in blood and urine of 76 patients and 26 controls by electrothermal atomic absorption spectroscopy. RESULTS A significant postoperative elevation of the metal concentrations was observed for total hip replacement patients in contrast to the control group. Twenty-nine patients exceeded the EKA (Expositionäquivalente für Krebserzeugende Arbeitsstoffe) threshold limits for cobalt in blood and for cobalt and chromium in urine. We obtained a significant correlation between cobalt in blood and cobalt in urine (r = 0.79; p < 0.005), chromium in blood and chromium in urine (r = 0.79; p < 0.005), cobalt in blood and chromium in blood (r = 0.69; p = 0.008), and cobalt in urine and chromium in urine (r = 0.95; p = 0.004). CONCLUSION Our findings suggest that in total hip replacements using metal-metal pairings, metal ions of the alloys are released. This release may lead to significantly elevated metal concentrations in biological fluids. Long-term studies are needed to determine the risk of metal-metal implants as a potential cause of cobalt and chromium toxicity.
Collapse
|
Clinical Trial |
25 |
122 |
17
|
Sunderman FW, Hopfer SM, Swift T, Rezuke WN, Ziebka L, Highman P, Edwards B, Folcik M, Gossling HR. Cobalt, chromium, and nickel concentrations in body fluids of patients with porous-coated knee or hip prostheses. J Orthop Res 2001; 7:307-15. [PMID: 2649648 DOI: 10.1002/jor.1100070302] [Citation(s) in RCA: 120] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Co, Cr, and Ni concentrations were determined by electrothermal atomic absorption spectrophotometry in serum and urine specimens collected from a group of 28 patients at intervals of from 1 day to 2.5 years after total knee or hip arthroplasty with porous-coated prostheses fabricated of Co-Cr alloy (ASTM F-75-82). Two control groups were also tested: (a) 42 healthy adults and (b) 16 orthopaedic patients after total knee or hip arthroplasty with porous-coated prostheses fabricated predominantly of Ti-Al-V alloy (ASTM F-136-84). All prostheses contained polyethylene components to avoid metal-to-metal contact. Mean Co concentrations in serum and urine were slightly increased in patients with Co-Cr knee implants at 6-120 weeks after surgery, compared with (a) preoperative values, (b) corresponding values in patients with Co-Cr hip implants, and (c) corresponding values in control patients with Ti-Al-V knee and hip prostheses. Substantially increased Co levels were observed in serum and urine of two patients at 7 weeks and 22 months postarthroplasty, associated with loosening of the prostheses; one of the patients also had elevated Cr levels in serum and urine. Although ASTM F-75-82 and F-136-84 alloys contain very little Ni (less than 1.0 and less than 0.2% Ni, respectively, by wt), mean Ni concentrations in serum and urine were greatly increased at 1-2 days after implantation of Ti-Al-V and Co-Cr prostheses, diminishing by 2 weeks. The postoperative hypernickelemia and nickeluresis may reflect contamination of the operative field with Ni-containing particles from the drills, cutting jigs, and drilling jigs, or it may represent a previously unrecognized pathophysiological response to surgery.
Collapse
|
Review |
24 |
120 |
18
|
Rizzetti MC, Liberini P, Zarattini G, Catalani S, Pazzaglia U, Apostoli P, Padovani A. Loss of sight and sound. Could it be the hip? Lancet 2009; 373:1052. [PMID: 19304018 DOI: 10.1016/s0140-6736(09)60490-6] [Citation(s) in RCA: 115] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
Case Reports |
16 |
115 |
19
|
Hart AJ, Hester T, Sinclair K, Powell JJ, Goodship AE, Pele L, Fersht NL, Skinner J. The association between metal ions from hip resurfacing and reduced T-cell counts. ACTA ACUST UNITED AC 2006; 88:449-54. [PMID: 16567777 DOI: 10.1302/0301-620x.88b4.17216] [Citation(s) in RCA: 108] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We have studied the relationship between metal ion levels and lymphocyte counts in patients with metal-on-metal hip resurfacings. Peripheral blood samples were analysed for lymphocyte subtypes and whole blood cobalt and chromium ion levels in 68 patients (34 with metal-on-metal hip resurfacings and 34 with standard metal-on-polyethylene total hip replacements). All hip components were radiologically well-fixed and the patients were asymptomatic. Cobalt and chromium levels were significantly elevated in the patients with metal-on-metal hip resurfacings, compared with the patients with standard metal-on-polyethylene designs (p < 0.0001). There was a statistically significant decrease in the level of CD8+ cells (T-cytotoxic/suppressor) (p = 0.005) in the metal-on-metal hip resurfacing group. A threshold level of blood cobalt and chromium ions was associated with reduced CD8+ T-cell counts. We have no evidence that our patients suffered as a result of this reduced level of CD8+ T-cells.
Collapse
|
|
19 |
108 |
20
|
Ghaedi M, Shokrollahi A, Ahmadi F, Rajabi HR, Soylak M. Cloud point extraction for the determination of copper, nickel and cobalt ions in environmental samples by flame atomic absorption spectrometry. JOURNAL OF HAZARDOUS MATERIALS 2008; 150:533-40. [PMID: 17604905 DOI: 10.1016/j.jhazmat.2007.05.029] [Citation(s) in RCA: 105] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2006] [Revised: 05/01/2007] [Accepted: 05/01/2007] [Indexed: 05/16/2023]
Abstract
A cloud point extraction procedure was presented for the preconcentration of copper, nickel and cobalt ions in various samples. After complexation with methyl-2-pyridylketone oxime (MPKO) in basic medium, analyte ions are quantitatively extracted to the phase rich in Triton X-114 following centrifugation. 1.0 mol L(-1) HNO(3) nitric acid in methanol was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The adopted concentrations for MPKO, Triton X-114 and HNO(3), bath temperature, centrifuge rate and time were optimized. Detection limits (3 SDb/m) of 1.6, 2.1 and 1.9 ng mL(-1) for Cu(2+), Co(2+) and Ni(2+) along with preconcentration factors of 30 and for these ions and enrichment factor of 65, 58 and 67 for Cu(2+), Ni(2+) and Co(2+), respectively. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated. The proposed procedure was applied to the analysis of biological, natural and wastewater, soil and blood samples.
Collapse
|
|
17 |
105 |
21
|
Witzleb WC, Ziegler J, Krummenauer F, Neumeister V, Guenther KP. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop 2006; 77:697-705. [PMID: 17068698 DOI: 10.1080/17453670610012863] [Citation(s) in RCA: 104] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND All metal implants--and metal-on-metal bearings in particular--corrode and cause a release of metal ions. Because cobalt and chromium have been shown to be carcinogenic and mutagenic in human and animal models, systemic toxicity and cancer risk are considered to be possible disadvantages of the metal-on-metal articulation. This study was designed to investigate the serum concentration profiles of chromium, cobalt and molybdenum after implantation of a Birmingham hip resurfacing arthroplasty (BHR) and a cementless total hip replacement with a 28-mm Metasul articulation (MTHR), over the first 2 years after implantation. METHODS We analyzed profiles of metal ion serum levels in 111 patients implanted with a BHR, in 74 patients implanted with an MTHR, and in 130 implant-free probands control subjects using atomic absorption spectrophotometry. RESULTS Chromium and cobalt concentrations (in microg/L) of all BHR and MTHR patients differed significantly from those of control subjects (chromium: < 0.25; cobalt: 0.25). The median chromium and cobalt concentrations in BHR patients had increased to 5.1 and 4.3 microg/L 2 years after surgery. Concentrations in BHR patient exceeded those in the unilateral MTHR patients. Molybdenum serum concentrations hardly changed over time in either group and were not significantly different from the concentrations seen in the control subjects. INTERPRETATION During the first 2 years after surgery, the Birmingham hip resurfacing arthroplasty leads to a significantly greater increase in serum chromium and cobalt levels than the 28-mm metal-on-metal MTHR. Observation of patients over a longer period will be necessary in order to evaluate any chronic adverse effects to the system due to elevated chromium and cobalt serum concentrations.
Collapse
|
Comparative Study |
19 |
104 |
22
|
Black J, Maitin EC, Gelman H, Morris DM. Serum concentrations of chromium, cobalt and nickel after total hip replacement: a six month study. Biomaterials 1983; 4:160-4. [PMID: 6615976 DOI: 10.1016/0142-9612(83)90003-0] [Citation(s) in RCA: 103] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Serum specimens were obtained from 15 patients before undergoing conventional total hip replacement and for periods of up to six months postoperatively. The specimens were analysed for chromium, cobalt and nickel by electrothermal atomic absorption spectroscopy. Serum chromium levels were found to rise to a pronounced postoperative peak and then diminish, although not falling to normal mean levels by six months. Serum cobalt levels either remained the same or decreased while serum nickel levels began to rise two to six weeks after surgery. These results are significant in that serum metal concentration changes have been reported for patients receiving metal-on-metal implants but not for patients with metal-on-polymer total hip implants of more modern designs.
Collapse
|
Comparative Study |
42 |
103 |
23
|
Abstract
Second-generation metal-on-metal (M/M) total hip replacements were introduced into clinical use in the late 1980s and demonstrate equivalent survivorship to conventional metal-on-polyethylene prostheses. Wear rates are comparable to those of first-generation designs that survived for a long time in the body. Biological effects from metal ions remain a concern. Patients with both first- and second-generation M/M hips have higher levels of cobalt and chromium in their blood and urine than either patients with metal-on-polyethylene devices or unoperated patients. Concerns include the potential for acquired hypersensitivity, mutagenicity, and carcinogenicity. However, reports of proven adverse effects are scant. Prospective, randomized trials with follow-up in excess of 15 years will be needed to differentiate between the performance and effects of M/M and other bearing combinations. Key words: totalhip arthroplasty, metal-on-metal, wear, biological effects, clinical results.
Collapse
|
Comparative Study |
20 |
102 |
24
|
Haeggström JZ, Wetterholm A, Shapiro R, Vallee BL, Samuelsson B. Leukotriene A4 hydrolase: a zinc metalloenzyme. Biochem Biophys Res Commun 1990; 172:965-70. [PMID: 2244921 DOI: 10.1016/0006-291x(90)91540-9] [Citation(s) in RCA: 100] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Purified human leukotriene A4 hydrolase is shown to contain 1 mol of zinc per mol of enzyme, as determined by atomic absorption spectrometry. The enzyme is inhibited dose-dependently by the chelating agents 8-hydroxy-quinoline-5-sulfonic acid, and 1,10-phenanthroline with KI values of about 2 and 8 x 10(-4) M, respectively, whereas dipicolinic acid and EDTA are ineffective in this respect. The inhibition by 1,10-phenanthroline is time-dependent, and at a concentration of 5 mM, 50% inhibition of enzyme (3 x 10(-7) M) occurs after about 15 min. The zinc atom of leukotriene A4 hydrolase can be removed by dialysis against 1,10-phenanthroline which results in loss of enzyme activity. The catalytic activity is almost completely restored by the addition of stoichiometric amounts of Zn2+ or Co2+.
Collapse
|
|
35 |
100 |
25
|
Brodner W, Grübl A, Jankovsky R, Meisinger V, Lehr S, Gottsauner-Wolf F. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty 2004; 19:66-70. [PMID: 15578556 DOI: 10.1016/j.arth.2004.09.003] [Citation(s) in RCA: 90] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
We investigated whether cup inclination influences serum levels of cobalt and chromium after metal-on-metal total hip arthroplasty. Out of a consecutive series, 3 groups of 20 patients each were established according to their cup inclination: greatest inclination (55 degrees -63 degrees, mean 58 degrees), intermediate inclination (44 degrees -46 degrees, mean 45 degrees), and smallest inclination (23 degrees -37 degrees, mean 33 degrees). We did not detect any statistically significant difference of serum cobalt (P = .23) or serum chromium (P = .13) levels between the 3 groups applying the Kruskal Wallis test. However, 3 patients with cup inclinations of 58 degrees , 63 degrees , and 61 degrees exhibited 9.8-53.6-fold elevated cobalt and 9.5-30.5-fold elevated chromium levels when compared with the median concentrations of this trial. We therefore recommend accurate cup placement also for metal-on-metal articulations.
Collapse
|
|
21 |
90 |