1
|
Vakoc BJ, Fukumura D, Jain RK, Bouma BE. Cancer imaging by optical coherence tomography: preclinical progress and clinical potential. Nat Rev Cancer 2012; 12:363-8. [PMID: 22475930 PMCID: PMC3560400 DOI: 10.1038/nrc3235] [Citation(s) in RCA: 180] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The past decade has seen dramatic technological advances in the field of optical coherence tomography (OCT) imaging. These advances have driven commercialization and clinical adoption in ophthalmology, cardiology and gastrointestinal cancer screening. Recently, an array of OCT-based imaging tools that have been developed for preclinical intravital cancer imaging applications has yielded exciting new capabilities to probe and to monitor cancer progression and response in vivo. Here, we review these results, forecast the future of OCT for preclinical cancer imaging and discuss its exciting potential to translate to the clinic as a tool for monitoring cancer therapy.
Collapse
|
Research Support, N.I.H., Extramural |
13 |
180 |
2
|
Sun N, Lee YT, Zhang RY, Kao R, Teng PC, Yang Y, Yang P, Wang JJ, Smalley M, Chen PJ, Kim M, Chou SJ, Bao L, Wang J, Zhang X, Qi D, Palomique J, Nissen N, Han SHB, Sadeghi S, Finn RS, Saab S, Busuttil RW, Markovic D, Elashoff D, Yu HH, Li H, Heaney AP, Posadas E, You S, Yang JD, Pei R, Agopian VG, Tseng HR, Zhu Y. Purification of HCC-specific extracellular vesicles on nanosubstrates for early HCC detection by digital scoring. Nat Commun 2020; 11:4489. [PMID: 32895384 PMCID: PMC7477161 DOI: 10.1038/s41467-020-18311-0] [Citation(s) in RCA: 149] [Impact Index Per Article: 29.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Accepted: 08/06/2020] [Indexed: 12/12/2022] Open
Abstract
We report a covalent chemistry-based hepatocellular carcinoma (HCC)-specific extracellular vesicle (EV) purification system for early detection of HCC by performing digital scoring on the purified EVs. Earlier detection of HCC creates more opportunities for curative therapeutic interventions. EVs are present in circulation at relatively early stages of disease, providing potential opportunities for HCC early detection. We develop an HCC EV purification system (i.e., EV Click Chips) by synergistically integrating covalent chemistry-mediated EV capture/release, multimarker antibody cocktails, nanostructured substrates, and microfluidic chaotic mixers. We then explore the translational potential of EV Click Chips using 158 plasma samples of HCC patients and control cohorts. The purified HCC EVs are subjected to reverse-transcription droplet digital PCR for quantification of 10 HCC-specific mRNA markers and computation of digital scoring. The HCC EV-derived molecular signatures exhibit great potential for noninvasive early detection of HCC from at-risk cirrhotic patients with an area under receiver operator characteristic curve of 0.93 (95% CI, 0.86 to 1.00; sensitivity = 94.4%, specificity = 88.5%).
Collapse
|
Observational Study |
5 |
149 |
3
|
Cai S, Pataillot-Meakin T, Shibakawa A, Ren R, Bevan CL, Ladame S, Ivanov AP, Edel JB. Single-molecule amplification-free multiplexed detection of circulating microRNA cancer biomarkers from serum. Nat Commun 2021; 12:3515. [PMID: 34112774 PMCID: PMC8192752 DOI: 10.1038/s41467-021-23497-y] [Citation(s) in RCA: 126] [Impact Index Per Article: 31.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 04/30/2021] [Indexed: 02/07/2023] Open
Abstract
MicroRNAs (miRNAs) play essential roles in post-transcriptional gene expression and are also found freely circulating in bodily fluids such as blood. Dysregulated miRNA signatures have been associated with many diseases including cancer, and miRNA profiling from liquid biopsies offers a promising strategy for cancer diagnosis, prognosis and monitoring. Here, we develop size-encoded molecular probes that can be used for simultaneous electro-optical nanopore sensing of miRNAs, allowing for ultrasensitive, sequence-specific and multiplexed detection directly in unprocessed human serum, in sample volumes as small as 0.1 μl. We show that this approach allows for femtomolar sensitivity and single-base mismatch selectivity. We demonstrate the ability to simultaneously monitor miRNAs (miR-141-3p and miR-375-3p) from prostate cancer patients with active disease and in remission. This technology can pave the way for next generation of minimally invasive diagnostic and companion diagnostic tests for cancer.
Collapse
|
research-article |
4 |
126 |
4
|
Messadi DV. Diagnostic aids for detection of oral precancerous conditions. Int J Oral Sci 2013; 5:59-65. [PMID: 23743617 PMCID: PMC3707069 DOI: 10.1038/ijos.2013.24] [Citation(s) in RCA: 125] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2012] [Accepted: 03/17/2013] [Indexed: 02/07/2023] Open
Abstract
Oral cancer has a tendency to be detected at late stage which is detrimental to the patients because of its high mortality and morbidity rates. Early detection of oral cancer is therefore important to reduce the burden of this devastating disease. In this review article, the most common oral precancerous lesions are discussed and the importance of early diagnosis is emphasized. In addition, the most common non-invasive oral cancer devices that can aid the general practitioners in early diagnosis are also discussed.
Collapse
|
Review |
12 |
125 |
5
|
Zheng T, Pierre-Pierre N, Yan X, Huo Q, Almodovar AJO, Valerio F, Rivera-Ramirez I, Griffith E, Decker DD, Chen S, Zhu N. Gold nanoparticle-enabled blood test for early stage cancer detection and risk assessment. ACS APPLIED MATERIALS & INTERFACES 2015; 7:6819-27. [PMID: 25757512 DOI: 10.1021/acsami.5b00371] [Citation(s) in RCA: 101] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
When citrate ligands-capped gold nanoparticles are mixed with blood sera, a protein corona is formed on the nanoparticle surface due to the adsorption of various proteins in the blood to the nanoparticles. Using a two-step gold nanoparticle-enabled dynamic light scattering assay, we discovered that the amount of human immunoglobulin G (IgG) in the gold nanoparticle protein corona is increased in prostate cancer patients compared to noncancer controls. Two pilot studies conducted on blood serum samples collected at Florida Hospital and obtained from Prostate Cancer Biorespository Network (PCBN) revealed that the test has a 90-95% specificity and 50% sensitivity in detecting early stage prostate cancer, representing a significant improvement over the current PSA test. The increased amount of human IgG found in the protein corona is believed to be associated with the autoantibodies produced in cancer patients as part of the immunodefense against tumor. Proteomic analysis of the nanoparticle protein corona revealed molecular profile differences between cancer and noncancer serum samples. Autoantibodies and natural antibodies produced in cancer patients in response to tumorigenesis have been found and detected in the blood of many cancer types. The test may be applicable for early detection and risk assessment of a broad spectrum of cancer. This new blood test is simple, low cost, requires only a few drops of blood sample, and the results are obtained within minutes. The test is well suited for screening purpose. More extensive studies are being conducted to further evaluate and validate the clinical potential of the new test.
Collapse
|
Evaluation Study |
10 |
101 |
6
|
Uthoff RD, Song B, Sunny S, Patrick S, Suresh A, Kolur T, Keerthi G, Spires O, Anbarani A, Wilder-Smith P, Kuriakose MA, Birur P, Liang R. Point-of-care, smartphone-based, dual-modality, dual-view, oral cancer screening device with neural network classification for low-resource communities. PLoS One 2018; 13:e0207493. [PMID: 30517120 PMCID: PMC6281283 DOI: 10.1371/journal.pone.0207493] [Citation(s) in RCA: 94] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Accepted: 10/30/2018] [Indexed: 01/17/2023] Open
Abstract
Oral cancer is a growing health issue in a number of low- and middle-income countries (LMIC), particularly in South and Southeast Asia. The described dual-modality, dual-view, point-of-care oral cancer screening device, developed for high-risk populations in remote regions with limited infrastructure, implements autofluorescence imaging (AFI) and white light imaging (WLI) on a smartphone platform, enabling early detection of pre-cancerous and cancerous lesions in the oral cavity with the potential to reduce morbidity, mortality, and overall healthcare costs. Using a custom Android application, this device synchronizes external light-emitting diode (LED) illumination and image capture for AFI and WLI. Data is uploaded to a cloud server for diagnosis by a remote specialist through a web app, with the ability to transmit triage instructions back to the device and patient. Finally, with the on-site specialist's diagnosis as the gold-standard, the remote specialist and a convolutional neural network (CNN) were able to classify 170 image pairs into 'suspicious' and 'not suspicious' with sensitivities, specificities, positive predictive values, and negative predictive values ranging from 81.25% to 94.94%.
Collapse
|
Research Support, N.I.H., Extramural |
7 |
94 |
7
|
Ralbovsky NM, Lednev IK. Raman spectroscopy and chemometrics: A potential universal method for diagnosing cancer. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 219:463-487. [PMID: 31075613 DOI: 10.1016/j.saa.2019.04.067] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 04/20/2019] [Accepted: 04/24/2019] [Indexed: 05/14/2023]
Abstract
Cancer is the second-leading cause of death worldwide. It affects an unfathomable number of people, with almost 16 million Americans currently living with it. While many cancers can be detected, current diagnostic efforts exhibit definite room for improvement. It is imperative that a person be diagnosed with cancer as early on in its progression as possible. An earlier diagnosis allows for the best treatment and intervention options available to be presented. Unfortunately, existing methods for diagnosing cancer can be expensive, invasive, inconclusive or inaccurate, and are not always made during initial stages of the disease. As such, there is a crucial unmet need to develop a singular universal method that is reliable, cost-effective, and non-invasive and can diagnose all forms of cancer early-on. Raman spectroscopy in combination with advanced statistical analysis is offered here as a potential solution for this need. This review covers recently published research in which Raman spectroscopy was used for the purpose of diagnosing cancer. The benefits and the risks of the methodology are presented; however, there is overwhelming evidence that suggests Raman spectroscopy is highly suitable for becoming the first universal method to be used for diagnosing cancer.
Collapse
|
Review |
6 |
61 |
8
|
Dik VK, Moons LMG, Siersema PD. Endoscopic innovations to increase the adenoma detection rate during colonoscopy. World J Gastroenterol 2014; 20:2200-2211. [PMID: 24605019 PMCID: PMC3942825 DOI: 10.3748/wjg.v20.i9.2200] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2013] [Revised: 12/06/2013] [Accepted: 01/20/2014] [Indexed: 02/06/2023] Open
Abstract
Up to a quarter of polyps and adenomas are missed during colonoscopy due to poor visualization behind folds and the inner curves of flexures, and the presence of flat lesions that are difficult to detect. These numbers may however be conservative because they mainly come from back-to-back studies performed with standard colonoscopes, which are unable to visualize the entire mucosal surface. In the past several years, new endoscopic techniques have been introduced to improve the detection of polyps and adenomas. The introduction of high definition colonoscopes and visual image enhancement technologies have been suggested to lead to better recognition of flat and small lesions, but the absolute increase in diagnostic yield seems limited. Cap assisted colonoscopy and water-exchange colonoscopy are methods to facilitate cecal intubation and increase patients comfort, but show only a marginal or no benefit on polyp and adenoma detection. Retroflexion is routinely used in the rectum for the inspection of the dentate line, but withdrawal in retroflexion in the colon is in general not recommended due to the risk of perforation. In contrast, colonoscopy with the Third-Eye Retroscope® may result in considerable lower miss rates compared to standard colonoscopy, but this technique is not practical in case of polypectomy and is more time consuming. The recently introduced Full Spectrum Endoscopy™ colonoscopes maintains the technical capabilities of standard colonoscopes and provides a much wider view of 330 degrees compared to the 170 degrees with standard colonoscopes. Remarkable lower adenoma miss rates with this new technique were recently demonstrated in the first randomized study. Nonetheless, more studies are required to determine the exact additional diagnostic yield in clinical practice. Optimizing the efficacy of colorectal cancer screening and surveillance requires high definition colonoscopes with improved virtual chromoendoscopy technology that visualize the whole colon mucosa while maintaining optimal washing, suction and therapeutic capabilities, and keeping the procedural time as low and patient discomfort as optimal as possible.
Collapse
|
Topic Highlight |
11 |
60 |
9
|
Porter E, Bahrami H, Santorelli A, Gosselin B, Rusch LA, Popovic M. A Wearable Microwave Antenna Array for Time-Domain Breast Tumor Screening. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:1501-1509. [PMID: 26780788 DOI: 10.1109/tmi.2016.2518489] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In this work, we present a clinical prototype with a wearable patient interface for microwave breast cancer detection. The long-term aim of the prototype is a breast health monitoring application. The system operates using multistatic time-domain pulsed radar, with 16 flexible antennas embedded into a bra. Unlike the previously reported, table-based prototype with a rigid cup-like holder, the wearable one requires no immersion medium and enables simple localization of breast surface. In comparison with the table-based prototype, the wearable one is also significantly more cost-effective and has a smaller footprint. To demonstrate the improved functionality of the wearable prototype, we here report the outcome of daily testing of the new, wearable prototype on a healthy volunteer over a 28-day period. The resulting data (both signals and reconstructed images) is compared to that obtained with our table-based prototype. We show that the use of the wearable prototype has improved the quality of collected volunteer data by every investigated measure. This work demonstrates the proof-of-concept for a wearable breast health monitoring array, which can be further optimized in the future for use with patients with various breast sizes and tissue densities.
Collapse
|
|
9 |
57 |
10
|
Schachschal G, Mayr M, Treszl A, Balzer K, Wegscheider K, Aschenbeck J, Aminalai A, Drossel R, Schröder A, Scheel M, Bothe CH, Bruhn JP, Burmeister W, Stange G, Bähr C, Kießlich R, Rösch T. Endoscopic versus histological characterisation of polyps during screening colonoscopy. Gut 2014; 63:458-65. [PMID: 23812324 DOI: 10.1136/gutjnl-2013-304562] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND As screening colonoscopy becomes more widespread, the costs for histopathological assessment of resected polyps are rising correspondingly. Reference centres have published highly accurate results for endoscopic polyp classification. Therefore, it has been proposed that, for smaller polyps, the differential diagnosis that guides follow-up recommendations could be based on endoscopy alone. OBJECTIVE The aim was to prospectively assess whether the high accuracy for endoscopic polyp diagnosis as reported by reference centres can be reproduced in routine screening colonoscopy. DESIGN Ten experienced private practice endoscopists had initial training in pit patterns. Then they assessed all polyps detected during 1069 screening colonoscopies. Patients (46% men; mean age 63 years) were randomly assigned to colonoscopy with conventional or latest generation HDTV instruments. The main outcome measure was diagnostic accuracy of in vivo polyp assessment (adenomatous vs hyperplastic). Secondary outcome measures were differences between endoscopes and reliability of image-based follow-up recommendations; a blinded post hoc analysis of polyp photographs was also performed. RESULTS 675 polyps were assessed (461 adenomatous, 214 hyperplastic). Accuracy, sensitivity and specificity of in vivo diagnoses were 76.6%, 78.1% and 73.4%; size of adenomas and endoscope withdrawal time significantly influenced accuracy. Image-based recommendations for post-polypectomy surveillance were correct in only 69.5% of cases. Post hoc analysis of polyp photographs did not improve accuracy. CONCLUSIONS In everyday practice, endoscopic classification of polyp type is not accurate enough to abandon histopathological assessment and use of latest generation colonoscopes does not improve this. Image-based surveillance recommendations after polypectomy would consequently not meet guideline requirements. TRIALREGNO NCT01297712.
Collapse
|
Comparative Study |
11 |
56 |
11
|
Quinn MK, Bubi TC, Pierce MC, Kayembe MK, Ramogola-Masire D, Richards-Kortum R. High-resolution microendoscopy for the detection of cervical neoplasia in low-resource settings. PLoS One 2012; 7:e44924. [PMID: 23028683 PMCID: PMC3445555 DOI: 10.1371/journal.pone.0044924] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2012] [Accepted: 08/09/2012] [Indexed: 02/07/2023] Open
Abstract
Cervical cancer is the second leading cause of cancer death among women in developing countries. Developing countries often lack infrastructure, cytotechnologists, and pathologists necessary to implement current screening tools. Due to their low cost and ease of interpretation at the point-of-care, optical imaging technologies may serve as an appropriate solution for cervical cancer screening in low resource settings. We have developed a high-resolution optical imaging system, the High Resolution Microendoscope (HRME), which can be used to interrogate clinically suspicious areas with subcellular spatial resolution, revealing changes in nuclear to cytoplasmic area ratio. In this pilot study carried out at the women's clinic of Princess Marina Hospital in Botswana, 52 unique sites were imaged in 26 patients, and the results were compared to histopathology as a reference standard. Quantitative high resolution imaging achieved a sensitivity and specificity of 86% and 87%, respectively, in differentiating neoplastic (≥CIN 2) tissue from non-neoplastic tissue. These results suggest the potential promise of HRME to assist in the detection of cervical neoplasia in low-resource settings.
Collapse
|
Research Support, N.I.H., Extramural |
13 |
55 |
12
|
Asiedu MN, Simhal A, Chaudhary U, Mueller JL, Lam CT, Schmitt JW, Venegas G, Sapiro G, Ramanujam N. Development of Algorithms for Automated Detection of Cervical Pre-Cancers With a Low-Cost, Point-of-Care, Pocket Colposcope. IEEE Trans Biomed Eng 2018; 66:2306-2318. [PMID: 30575526 DOI: 10.1109/tbme.2018.2887208] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
GOAL In this paper, we propose methods for (1) automatic feature extraction and classification for acetic acid and Lugol's iodine cervigrams and (2) methods for combining features/diagnosis of different contrasts in cervigrams for improved performance. METHODS We developed algorithms to pre-process pathology-labeled cervigrams and extract simple but powerful color and textural-based features. The features were used to train a support vector machine model to classify cervigrams based on corresponding pathology for visual inspection with acetic acid, visual inspection with Lugol's iodine, and a combination of the two contrasts. RESULTS The proposed framework achieved a sensitivity, specificity, and accuracy of 81.3%, 78.6%, and 80.0%, respectively, when used to distinguish cervical intraepithelial neoplasia (CIN+) relative to normal and benign tissues. This is superior to the average values achieved by three expert physicians on the same data set for discriminating normal/benign cases from CIN+ (77% sensitivity, 51% specificity, and 63% accuracy). CONCLUSION The results suggest that utilizing simple color- and textural-based features from visual inspection with acetic acid and visual inspection with Lugol's iodine images may provide unbiased automation of cervigrams. SIGNIFICANCE This would enable automated, expert-level diagnosis of cervical pre-cancer at the point of care.
Collapse
|
Research Support, U.S. Gov't, Non-P.H.S. |
7 |
52 |
13
|
Hanken H, Kraatz J, Smeets R, Heiland M, Blessmann M, Eichhorn W, Clauditz TS, Gröbe A, Kolk A, Rana M. The detection of oral pre- malignant lesions with an autofluorescence based imaging system (VELscope™) - a single blinded clinical evaluation. Head Face Med 2013; 9:23. [PMID: 23967796 PMCID: PMC3851797 DOI: 10.1186/1746-160x-9-23] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Accepted: 08/20/2013] [Indexed: 01/16/2023] Open
Abstract
OBJECTIVE The disease specific five-year survival rate especially for patients with advanced oral cancer has not improved significantly over the period of time. The most effective way of combating this dilemma is an early detection, diagnosis and eradication of early-stage lesions and their precursors. The use of VELscope® using an autofluorescence as a diagnostic tool might be useful in early detection of oral malignant lesions. MATERIALS AND METHODS 120 patients with suspicious oral premalignant lesions were examined with two examination methods. They were randomly divided into two groups. Group 1 was examined conventional with white-light and group 2 was examined additionally to the white-light-examination with an autofluorescence visualization device, VELscope®. Biopsies were obtained from all suspicious areas identified in both examination groups (n = 52). The diagnostic strategies were compared regarding sensitivity and specificity. RESULTS Based upon the result, use of the VELscope® leads to a higher sensitivity (22.0%), but regarding specificity the additional use of the VELscope® is inferior (8.4%). CONCLUSION The VELscope device is a simple, non-invasive test of the oral mucosa, which can help the experienced clinician to find oral precursor malignant lesions.
Collapse
|
Randomized Controlled Trial |
12 |
52 |
14
|
Chuchu N, Takwoingi Y, Dinnes J, Matin RN, Bassett O, Moreau JF, Bayliss SE, Davenport C, Godfrey K, O'Connell S, Jain A, Walter FM, Deeks JJ, Williams HC, Cochrane Skin Cancer Diagnostic Test Accuracy Group, Cochrane Skin Group. Smartphone applications for triaging adults with skin lesions that are suspicious for melanoma. Cochrane Database Syst Rev 2018; 12:CD013192. [PMID: 30521685 PMCID: PMC6517294 DOI: 10.1002/14651858.cd013192] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND Melanoma accounts for a small proportion of all skin cancer cases but is responsible for most skin cancer-related deaths. Early detection and treatment can improve survival. Smartphone applications are readily accessible and potentially offer an instant risk assessment of the likelihood of malignancy so that the right people seek further medical attention from a clinician for more detailed assessment of the lesion. There is, however, a risk that melanomas will be missed and treatment delayed if the application reassures the user that their lesion is low risk. OBJECTIVES To assess the diagnostic accuracy of smartphone applications to rule out cutaneous invasive melanoma and atypical intraepidermal melanocytic variants in adults with concerns about suspicious skin lesions. SEARCH METHODS We undertook a comprehensive search of the following databases from inception to August 2016: Cochrane Central Register of Controlled Trials; MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists and published systematic review articles. SELECTION CRITERIA Studies of any design evaluating smartphone applications intended for use by individuals in a community setting who have lesions that might be suspicious for melanoma or atypical intraepidermal melanocytic variants versus a reference standard of histological confirmation or clinical follow-up and expert opinion. DATA COLLECTION AND ANALYSIS Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on QUADAS-2). Due to scarcity of data and poor quality of studies, we did not perform a meta-analysis for this review. For illustrative purposes, we plotted estimates of sensitivity and specificity on coupled forest plots for each application under consideration. MAIN RESULTS This review reports on two cohorts of lesions published in two studies. Both studies were at high risk of bias from selective participant recruitment and high rates of non-evaluable images. Concerns about applicability of findings were high due to inclusion only of lesions already selected for excision in a dermatology clinic setting, and image acquisition by clinicians rather than by smartphone app users.We report data for five mobile phone applications and 332 suspicious skin lesions with 86 melanomas across the two studies. Across the four artificial intelligence-based applications that classified lesion images (photographs) as melanomas (one application) or as high risk or 'problematic' lesions (three applications) using a pre-programmed algorithm, sensitivities ranged from 7% (95% CI 2% to 16%) to 73% (95% CI 52% to 88%) and specificities from 37% (95% CI 29% to 46%) to 94% (95% CI 87% to 97%). The single application using store-and-forward review of lesion images by a dermatologist had a sensitivity of 98% (95% CI 90% to 100%) and specificity of 30% (95% CI 22% to 40%).The number of test failures (lesion images analysed by the applications but classed as 'unevaluable' and excluded by the study authors) ranged from 3 to 31 (or 2% to 18% of lesions analysed). The store-and-forward application had one of the highest rates of test failure (15%). At least one melanoma was classed as unevaluable in three of the four application evaluations. AUTHORS' CONCLUSIONS Smartphone applications using artificial intelligence-based analysis have not yet demonstrated sufficient promise in terms of accuracy, and they are associated with a high likelihood of missing melanomas. Applications based on store-and-forward images could have a potential role in the timely presentation of people with potentially malignant lesions by facilitating active self-management health practices and early engagement of those with suspicious skin lesions; however, they may incur a significant increase in resource and workload. Given the paucity of evidence and low methodological quality of existing studies, it is not possible to draw any implications for practice. Nevertheless, this is a rapidly advancing field, and new and better applications with robust reporting of studies could change these conclusions substantially.
Collapse
|
Systematic Review |
7 |
50 |
15
|
Fink C, Haenssle HA. Non-invasive tools for the diagnosis of cutaneous melanoma. Skin Res Technol 2017; 23:261-271. [PMID: 27878858 DOI: 10.1111/srt.12350] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2016] [Indexed: 01/11/2023]
Abstract
BACKGROUND While the excisional biopsy and histological examination of suspicious lesions remains the current gold standard for diagnosing cutaneous melanoma (CM), there is a demand for more objective and non-invasive examination methods that may support clinicians in their decision when to biopsy or not. METHODS This review is based on publications and guidelines retrieved by a selective search in PubMed and MEDLINE and focused on non-invasive diagnostic strategies for detecting melanoma. RESULTS Ten different non-invasive techniques were compared with regard to applicability, status of development, and resources necessary for introduction into clinical routine (dermoscopy, sequential digital dermoscopy, total body photography, computer-aided multispectral digital analysis, electrical impedance spectroscopy, Raman spectroscopy, reflectance confocal microscopy, multiphoton tomography, stepwise two-photon-laser spectroscopy, quantitative dynamic infrared imaging). In an effort to create a classification based on our analyses, we suggest to differentiate i) tools for screening of patients in daily clinical routine, ii) tools for examination of a restricted number of preselected lesions that produce an automated diagnostic score, iii) tools for examination of a restricted number of preselected lesions at specialized centers requiring extensive training, iv) devices at an experimental stage of development. CONCLUSION None of the discussed examination techniques is able to provide a definite and final diagnosis or to completely replace the histopathological examination. Up to date, the need for fully automated devices offering a complete skin cancer screening has not been satisfied.
Collapse
|
Comparative Study |
8 |
49 |
16
|
Denzer UW, Rösch T, Hoytat B, Abdel-Hamid M, Hebuterne X, Vanbiervielt G, Filippi J, Ogata H, Hosoe N, Ohtsuka K, Ogata N, Ikeda K, Aihara H, Kudo SE, Tajiri H, Treszl A, Wegscheider K, Greff M, Rey JF. Magnetically guided capsule versus conventional gastroscopy for upper abdominal complaints: a prospective blinded study. J Clin Gastroenterol 2015; 49:101-107. [PMID: 24618504 DOI: 10.1097/mcg.0000000000000110] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Upper gastrointestinal endoscopy is mostly performed under sedation and has a low yield of relevant gastric lesions in patients without alarm symptoms. Simpler screening tests such as capsule endoscopy could be helpful, but gastric visualization is insufficient with the current passive capsules. A magnetically guided gastric capsule was prospectively evaluated in patients with routine indications for gastroscopy. METHODS A total of 189 symptomatic patients (105 male; mean age 53 y) from 2 French centers subsequently and blindly underwent capsule and conventional gastroscopy by 9 and 6 examiners, respectively. The final gold standard was unblinded conventional gastroscopy with biopsy under propofol sedation. Main outcome was accuracy (sensitivity/specificity) of capsule gastroscopy for diagnosis of major gastric lesions, defined as those lesions requiring conventional gastroscopy for biopsy or removal. RESULTS Twenty-three major lesions were found in 21 patients. Capsule accuracy was 90.5% [95% confidence interval (CI), 85.4%-94.3%] with a specificity of 94.1% (95% CI, 89.3%-97.1%) and a sensitivity of 61.9% (95% CI, 38%-82%). Accuracy did not correlate with lesion location, gastric luminal visibility, examiner case volume, or examination time. Of the remaining 168 patients, 94% had minor and mostly multiple lesions; the capsule made a correct diagnosis in 88.1% (95% CI, 82.2%-92.6%), with gastric visibility and lesion location in the proximal stomach having significant influence. All patients preferred capsule gastroscopy. CONCLUSIONS In a prospective and strictly blinded study, magnetically guided capsule gastroscopy was shown to be feasible in clinical practice and was clearly preferred by patients. Improvements in capsule technology may render this technique a future alternative to gastroscopy.
Collapse
|
Clinical Trial |
10 |
48 |
17
|
Du J, Li Y, Lv S, Wang Q, Sun C, Dong X, He M, Ulain Q, Yuan Y, Tuo X, Batchu N, Song Q, Li Q. Endometrial sampling devices for early diagnosis of endometrial lesions. J Cancer Res Clin Oncol 2016; 142:2515-2522. [PMID: 27515060 PMCID: PMC5095161 DOI: 10.1007/s00432-016-2215-3] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Accepted: 08/03/2016] [Indexed: 11/25/2022]
Abstract
PURPOSE Endometrial carcinoma is the most common gynecologic malignancy in both developed and some developing countries. Unlike cervical cancer, for which there is routine screening, only patients symptomatic for endometrial carcinoma typically seek medical help for its diagnosis and treatment. Dilatation and curettage (D&C) has been the standard procedure for evaluating suspicious endometrial lesions. The discomfort and injury caused by the D&C procedure, however, restrict its use as a screening method for early diagnosis of endometrial lesions. High-risk endometrial cancer patients would benefit from an effective and low-cost screening test. In recent years, several endometrial devices have been developed and proposed as screening tools. METHODS We have reviewed and evaluated the literature relating to the endometrial sampling devices in clinical use or clinical trials, with the goal of comparing devices and identifying the most appropriate ones for screening for endometrial lesions. Eligible literature was identified from systematic PubMed searches, and the relevant data were extracted. Comments, letters, unpublished data, conference proceedings, and case reports were excluded from our search. Seventy-four articles on endometrial sampling devices were obtained for this review. RESULTS The main screening devices for endometrial carcinoma are aspiration devices (such as the Vabra aspirator), Pipelle, Tao Brush, and SAP-1 device. Among these devices, the Tao Brush is the most promising endometrial sampler for screening for endometrial lesions. However, its sampling insufficiency, cost, and unsuccessful insertion rate (20 % in nulliparous and 8 % in parous women) are problematic. CONCLUSIONS A more accurate and low-cost endometrial sampler, with improved specimen sufficiency and higher sensitivity for endometrial lesions, needs tobe developed and clinically verified.
Collapse
|
Review |
9 |
47 |
18
|
O'Connor M, Gallagher P, Waller J, Martin CM, O'Leary JJ, Sharp L. Adverse psychological outcomes following colposcopy and related procedures: a systematic review. BJOG 2016; 123:24-38. [PMID: 26099164 DOI: 10.1111/1471-0528.13462] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/02/2015] [Indexed: 11/28/2022]
Abstract
BACKGROUND Although colposcopy is the leading follow-up option for women with abnormal cervical cytology, little is known about its psychological consequences. OBJECTIVES We performed a systematic review to examine: (1) what, if any, are the adverse psychological outcomes following colposcopy and related procedures; (2) what are the predictors of adverse psychological outcomes post-colposcopy; and (3) what happens to these outcomes over time. SEARCH STRATEGY Five electronic databases (PubMed, PsychINFO, CINAHL, Web of Science, Scopus) were searched for studies published in English between January 1986 and February 2014. SELECTION CRITERIA Eligible studies assessed psychological wellbeing at one or more time-points post-colposcopy. DATA COLLECTION AND ANALYSIS Two reviewers independently screened titles and abstracts. Full texts of potentially eligible papers were reviewed. Data were abstracted from, and a quality appraisal performed of, eligible papers. MAIN RESULTS Twenty-three papers reporting 16 studies were eligible. Colposcopy and related procedures can lead to adverse psychological outcomes, particularly anxiety. Ten studies investigated predictors of adverse psychological outcomes; management type and treatment had no impact on this. Seven studies investigated temporal trends in psychological outcomes post-colposcopy; findings were mixed, especially in relation to anxiety and distress. Studies were methodologically heterogeneous. CONCLUSIONS Follow-up investigations and procedures for abnormal cervical cytology can cause adverse psychological outcomes among women. However, little is known about the predictors of these outcomes or how long they persist. There is a need for a more standardised approach to the examination of the psychological impact of colposcopy, especially longer-term outcomes. TWEETABLE ABSTRACT Follow-up investigations for abnormal cervical cytology can cause adverse psychological outcome among women.
Collapse
|
Review |
9 |
46 |
19
|
de Gelder R, Fracheboud J, Heijnsdijk EAM, den Heeten G, Verbeek ALM, Broeders MJM, Draisma G, de Koning HJ. Digital mammography screening: weighing reduced mortality against increased overdiagnosis. Prev Med 2011; 53:134-40. [PMID: 21718717 DOI: 10.1016/j.ypmed.2011.06.009] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2011] [Revised: 06/09/2011] [Accepted: 06/13/2011] [Indexed: 11/17/2022]
Abstract
OBJECTIVE Digital mammography has been shown to increase the detection of ductal carcinoma in situ (DCIS) compared to screen-film mammography. The benefits and risks of such an increase were assessed. METHODS Breast cancer detection rates were compared between 502,574 screen-film and 83,976 digital mammograms performed between 2004 and 2006 among Dutch screening participants. The detection rates were then modeled using a baseline model and two extreme models that respectively assumed a high rate of progression and no progression of preclinical DCIS to invasive cancer. With these models, breast cancer mortality and overdiagnosis were predicted. RESULTS The DCIS detection rate was significantly higher at digital mammography (1.2 per 1000 mammograms (95% C.I. 1.0-1.5)) than at screen-film mammography (0.7 per 1000 mammograms (95% C.I. 0.6-0.7)). Consequently, 287 (range progressive- non progressive model: 1-598) extra breast cancer deaths per 1,000,000 women (a 4.4% increase) were predicted to be prevented. An extra 401 (range: 165-2271) cancers would be overdiagnosed (a 21% increase). CONCLUSION Modeling predicted that digital mammography screening would further reduce breast cancer mortality by 4.4%, at a 21% increased overdiagnosis rate. The consequences of digital screening, however, are sensitive to underlying assumptions on the natural history of DCIS.
Collapse
|
Comparative Study |
14 |
46 |
20
|
Catarino R, Vassilakos P, Scaringella S, Undurraga-Malinverno M, Meyer-Hamme U, Ricard-Gauthier D, Matute JC, Petignat P. Smartphone Use for Cervical Cancer Screening in Low-Resource Countries: A Pilot Study Conducted in Madagascar. PLoS One 2015. [PMID: 26222772 PMCID: PMC4519052 DOI: 10.1371/journal.pone.0134309] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Background Visual inspection of the cervix after application of 5% acetic acid (VIA) is a screening technique for cervical cancer used widely in low and middle-income countries (LMIC). To improve VIA screening performance, digital images after acid acetic application (D-VIA) are taken. The aim of this study was to evaluate the use of a smartphone for on- and off-site D-VIA diagnosis. Materials and Methods Women aged 30–65 years, living in the city of Ambanja, Madagascar, were recruited through a cervical cancer screening campaign. Each performed a human papillomavirus (HPV) self-sample as a primary screen. Women testing positive for HPV were referred for VIA followed by D-VIA, cervical biopsy and endocervical curettage according to routine protocol. In addition, the same day, the D-VIA was emailed to a tertiary care center for immediate assessment. Results were scored as either D-VIA normal or D-VIA abnormal, requiring immediate therapy or referral to a tertiary center. Each of the three off-site physicians were blinded to the result reported by the one on-site physician and each gave their individual assessment followed by a consensus diagnosis. Statistical analyses were conducted using STATA software. Results Of the 332 women recruited, 137 (41.2%) were HPV-positive and recalled for VIA triage; compliance with this invitation was 69.3% (n = 95). Cervical intraepithelial neoplasia was detected in 17.7% and 21.7% of digital images by on-site and off-site physicians, respectively. The on-site physician had a sensitivity of 66.7% (95%CI: 30.0–90.3) and a specificity of 85.7% (95%CI: 76.7–91.6); the off-site physician consensus sensitivity was 66.7% (95%CI: 30.0–90.3) with a specificity of 82.3% (95%CI: 72.4–89.1). Conclusion This pilot study supports the use of telemedicine for off-site diagnosis of cervical intraepithelial neoplasia, with diagnostic performance similar to those achieved on-site. Further studies need to determine if smartphones can improve cervical cancer screening efficiency in LMIC.
Collapse
|
Research Support, Non-U.S. Gov't |
10 |
45 |
21
|
Field AS, Schmitt F, Vielh P. IAC Standardized Reporting of Breast Fine-Needle Aspiration Biopsy Cytology. Acta Cytol 2016; 61:3-6. [PMID: 27806362 DOI: 10.1159/000450880] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Accepted: 09/15/2016] [Indexed: 11/19/2022]
Abstract
There have been many changes in the roles of fine-needle aspiration biopsy (FNAB) and core needle biopsy (CNB) in the diagnostic workup of breast lesions in routine breast clinics and in mammographic breast screening programs, as well as changes in the management algorithms utilized and the treatments available, since the NCI consensus on breast FNAB cytology in 1996. A standardized approach will improve training and performance of FNAB and smear-making techniques, and structured reporting will improve the quality and reproducibility of reports across departments, cities and countries providing a basis for quality assurance measures and improving patient care and facilitating research. Linking cytology reports to management algorithms will increase the clinicians' use of FNAB cytology and where appropriate CNB, and enhance the use of ancillary tests for prognostic testing. The IAC recognizes that the local medical infrastructure and resources for breast imaging, biopsy and treatment will influence the diagnostic workup and management of breast disease, but best practice guidelines should be established and modified as required.
Collapse
|
|
9 |
45 |
22
|
Ferrante JM, Fyffe DC, Vega ML, Piasecki AK, Ohman-Strickland PA, Crabtree BF. Family physicians' barriers to cancer screening in extremely obese patients. Obesity (Silver Spring) 2010; 18:1153-9. [PMID: 20019676 PMCID: PMC2953250 DOI: 10.1038/oby.2009.481] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Extremely obese women are less likely than nonobese women to receive breast and cervical cancer screening examinations. Reasons for this disparity are unclear and may stem from patient and/or physician barriers. This sequential mixed-methods study used individual in-depth interviews of 15 family physicians followed by a mail survey of 255 family physicians (53% response rate) to understand the barriers they faced in performing cancer screening examinations in extremely obese women. Barriers fell into three main areas: (i) difficulty doing pelvic and breast exams; (ii) inadequate equipment; and (iii) challenges overcoming patient barriers and refusal. This led some physicians to avoid performing breast and pelvic examinations on extremely obese women. Having more knowledge about specific examination techniques was associated with less difficulty in palpating lumps on breast and pelvic examinations (P < 0.005). Physicians perceived that embarrassment, aversion to undressing, and avoidance of discussions related to their weight were the most frequent barriers extremely obese women had with getting physical examinations. Educating and/or motivating patients and addressing fears were strategies used most frequently when patients refused mammograms or Pap smears. Interventions focusing on physician barriers, such as educating them on specific examination techniques, obtaining adequate equipment and supplies, and providing resources to assist physicians in dealing with patient barriers and refusal, may be fruitful in increasing cancer screening rates in extremely obese patients. Future research studies testing the effectiveness of these strategies are needed to improve cancer outcomes in this high-risk population.
Collapse
|
Evaluation Study |
15 |
38 |
23
|
Hamashima C, Goto R. Potential capacity of endoscopic screening for gastric cancer in Japan. Cancer Sci 2017; 108:101-107. [PMID: 27727490 PMCID: PMC5276833 DOI: 10.1111/cas.13100] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 10/04/2016] [Accepted: 10/06/2016] [Indexed: 11/28/2022] Open
Abstract
In 2016, the Japanese government decided to introduce endoscopic screening for gastric cancer as a national program. To provide endoscopic screening nationwide, we estimated the proportion of increase in the number of endoscopic examinations with the introduction of endoscopic screening, based on a national survey. The total number of endoscopic examinations has increased, particularly in clinics. Based on the national survey, the total number of participants in gastric cancer screening was 3 784 967. If 30% of the participants are switched from radiographic screening to endoscopic screening, approximately 1 million additional endoscopic examinations are needed. In Japan, the participation rates in gastric cancer screening and the number of hospitals and clinics offering upper gastrointestinal endoscopy vary among the 47 prefectures. If the participation rates are high and the numbers of hospitals and clinics are small, the proportion of increase becomes larger. Based on the same assumption, 50% of big cities can provide endoscopic screening with a 5% increase in the total number of endoscopic examinations. However, 16.7% of the medical districts are available for endoscopic screening within a 5% increase in the total number of endoscopic examinations. Despite the Japanese government's decision to introduce endoscopic screening for gastric cancer nationwide, its immediate introduction remains difficult because of insufficient medical resources in rural areas. This implies that endoscopic screening will be initially introduced to big cities. To promote endoscopic screening for gastric cancer nationwide, the disparity of medical resources must first be resolved.
Collapse
|
research-article |
8 |
38 |
24
|
Triantafyllou K, Polymeros D, Apostolopoulos P, Lopes Brandao C, Gkolfakis P, Repici A, Papanikolaou IS, Dinis-Ribeiro M, Alexandrakis G, Hassan C. Endocuff-assisted colonoscopy is associated with a lower adenoma miss rate: a multicenter randomized tandem study. Endoscopy 2017; 49:1051-1060. [PMID: 28763808 DOI: 10.1055/s-0043-114412] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Background and study aims The Endocuff (ARC Medical Design, Leeds, UK) is a device that, when mounted on the tip of an endoscope, may assist with inspection of a greater surface of the colonic mucosa by pulling backwards, flattening, and stretching the colonic folds as the endoscope is gradually withdrawn. We aimed to compare the adenoma miss rates of Endocuff-assisted colonoscopy with those of conventional colonoscopy. Patients and methods The included patients underwent same-day, back-to-back, (Endocuff-assisted colonoscopy as the index procedure followed by conventional colonoscopy or vice versa, randomly assigned 1:1) colonoscopies, performed by six endoscopists with documented adenoma detection rates > 35 %, in four tertiary endoscopy facilities. Results We randomized 200 patients (mean age 61.2 years [standard deviation 9.8]; 86.5 % colorectal cancer screening surveillance cases). Overall, there were seven incomplete examinations using Endocuff and one with conventional colonoscopy (P = 0.03). Times for endoscope insertion (5.0 minutes [0.8 - 21.0] vs. 5.0 minutes [1.0 - 16.0]; P = 0.49) and withdrawal (6.0 minutes [3.2 - 29.0] vs. 6.0 minutes [3.1 - 17.0]; P = 0.06) were similar for Endocuff-assisted and conventional colonoscopy. We detected one cancer and 195 adenomas; 84 in the proximal colon. Endocuff-assisted colonoscopy showed significantly lower overall and proximal colon adenoma miss rates compared with conventional colonoscopy (14.7 % [8.0 % - 21.0 %] vs. 38.4 % [28.1 % - 48.6 %] and 10.4 % [1.8 % - 19.1 %] vs. 38.9 % [23.0 % - 54.8 %], respectively). No difference between the two arms was shown regarding advanced adenoma miss rates, either overall or in the proximal colon. There were no serious adverse events related to the procedures. Conclusions In comparison with conventional colonoscopy, Endocuff-assisted colonoscopy has a significantly lower adenoma miss rate when performed by high-detector endoscopists. However, the incomplete colonoscopy rate with Endocuff is higher.ClinicalTrials.gov Identifier: NCT02340065.
Collapse
|
Comparative Study |
8 |
36 |
25
|
Myers RE, Daskalakis C, Kunkel EJS, Cocroft JR, Riggio JM, Capkin M, Braddock CH. Mediated decision support in prostate cancer screening: a randomized controlled trial of decision counseling. PATIENT EDUCATION AND COUNSELING 2011; 83:240-246. [PMID: 20619576 DOI: 10.1016/j.pec.2010.06.011] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2009] [Revised: 05/28/2010] [Accepted: 06/05/2010] [Indexed: 05/29/2023]
Abstract
OBJECTIVE This randomized trial was conducted to assess the impact of a mediated decision support intervention on primary care patient prostate cancer screening knowledge, decisional conflict, informed decision making (IDM), and screening. METHODS Before a routine office visit, 313 male patients eligible for prostate cancer screening completed a baseline telephone survey and received a mailed brochure on prostate cancer screening. At the visit, participants were randomized to either an enhanced intervention (EI) or a standard intervention (SI) group. Before meeting with their physician, EI Group men had a nurse-led "decision counseling" session, while SI Group men completed a practice satisfaction survey. An endpoint survey was administered. Survey data, encounter audio-recordings, and chart audit data were used to assess study outcomes. RESULTS Knowledge increased in the EI Group (mean difference of +0.8 on a 10-point scale, p=0.001), but decisional conflict did not change (mean difference of -0.02 on a 4-point scale, p=0.620). The EI Group had higher IDM (rate ratio=1.30, p=0.029) and lower screening (odds ratio=0.67, p=0.102). CONCLUSION Nurse-mediated decision counseling increased participant prostate cancer screening knowledge, and influenced informed decision making and screening. PRACTICE IMPLICATIONS Nurses trained in decision counseling can facilitate shared decision making about screening.
Collapse
|
Randomized Controlled Trial |
14 |
35 |