1
|
Liu H, Logan BE. Electricity generation using an air-cathode single chamber microbial fuel cell in the presence and absence of a proton exchange membrane. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2004; 38:4040-6. [PMID: 15298217 DOI: 10.1021/es0499344] [Citation(s) in RCA: 787] [Impact Index Per Article: 37.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Microbial fuel cells (MFCs) are typically designed as a two-chamber system with the bacteria in the anode chamber separated from the cathode chamber by a polymeric proton exchange membrane (PEM). Most MFCs use aqueous cathodes where water is bubbled with air to provide dissolved oxygen to electrode. To increase energy output and reduce the cost of MFCs, we examined power generation in an air-cathode MFC containing carbon electrodes in the presence and absence of a polymeric proton exchange membrane (PEM). Bacteria present in domestic wastewater were used as the biocatalyst, and glucose and wastewater were tested as substrates. Power density was found to be much greater than typically reported for aqueous-cathode MFCs, reaching a maximum of 262 +/- 10 mW/m2 (6.6 +/- 0.3 mW/L; liquid volume) using glucose. Removing the PEM increased the maximum power density to 494 +/- 21 mW/m2 (12.5 +/- 0.5 mW/L). Coulombic efficiency was 40-55% with the PEM and 9-12% with the PEM removed, indicating substantial oxygen diffusion into the anode chamber in the absence of the PEM. Power output increased with glucose concentration according to saturation-type kinetics, with a half saturation constant of 79 mg/L with the PEM-MFC and 103 mg/L in the MFC without a PEM (1000 omega resistor). Similar results on the effect of the PEM on power density were found using wastewater, where 28 +/- 3 mW/m2 (0.7 +/- 0.1 mW/L) (28% Coulombic efficiency) was produced with the PEM, and 146 +/- 8 mW/m2 (3.7 +/- 0.2 mW/L) (20% Coulombic efficiency) was produced when the PEM was removed. The increase in power output when a PEM was removed was attributed to a higher cathode potential as shown by an increase in the open circuit potential. An analysis based on available anode surface area and maximum bacterial growth rates suggests that mediatorless MFCs may have an upper order-of-magnitude limit in power density of 10(3) mW/m2. A cost-effective approach to achieving power densities in this range will likely require systems that do not contain a polymeric PEM in the MFC and systems based on direct oxygen transfer to a carbon cathode.
Collapse
|
|
21 |
787 |
2
|
Chaudhuri SK, Lovley DR. Electricity generation by direct oxidation of glucose in mediatorless microbial fuel cells. Nat Biotechnol 2003; 21:1229-32. [PMID: 12960964 DOI: 10.1038/nbt867] [Citation(s) in RCA: 642] [Impact Index Per Article: 29.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2003] [Accepted: 07/10/2003] [Indexed: 11/08/2022]
Abstract
Abundant energy, stored primarily in the form of carbohydrates, can be found in waste biomass from agricultural, municipal and industrial sources as well as in dedicated energy crops, such as corn and other grains. Potential strategies for deriving useful forms of energy from carbohydrates include production of ethanol and conversion to hydrogen, but these approaches face technical and economic hurdles. An alternative strategy is direct conversion of sugars to electrical power. Existing transition metal-catalyzed fuel cells cannot be used to generate electric power from carbohydrates. Alternatively, biofuel cells in which whole cells or isolated redox enzymes catalyze the oxidation of the sugar have been developed, but their applicability has been limited by several factors, including (i) the need to add electron-shuttling compounds that mediate electron transfer from the cell to the anode, (ii) incomplete oxidation of the sugars and (iii) lack of long-term stability of the fuel cells. Here we report on a novel microorganism, Rhodoferax ferrireducens, that can oxidize glucose to CO(2) and quantitatively transfer electrons to graphite electrodes without the need for an electron-shuttling mediator. Growth is supported by energy derived from the electron transfer process itself and results in stable, long-term power production.
Collapse
|
|
22 |
642 |
3
|
Abstract
Ultrasonic biophysics is the study of mechanisms responsible for how ultrasound and biological materials interact. Ultrasound-induced bioeffect or risk studies focus on issues related to the effects of ultrasound on biological materials. On the other hand, when biological materials affect the ultrasonic wave, this can be viewed as the basis for diagnostic ultrasound. Thus, an understanding of the interaction of ultrasound with tissue provides the scientific basis for image production and risk assessment. Relative to the bioeffect or risk studies, that is, the biophysical mechanisms by which ultrasound affects biological materials, ultrasound-induced bioeffects are generally separated into thermal and non-thermal mechanisms. Ultrasonic dosimetry is concerned with the quantitative determination of ultrasonic energy interaction with biological materials. Whenever ultrasonic energy is propagated into an attenuating material such as tissue, the amplitude of the wave decreases with distance. This attenuation is due to either absorption or scattering. Absorption is a mechanism that represents that portion of ultrasonic wave that is converted into heat, and scattering can be thought of as that portion of the wave, which changes direction. Because the medium can absorb energy to produce heat, a temperature rise may occur as long as the rate of heat production is greater than the rate of heat removal. Current interest with thermally mediated ultrasound-induced bioeffects has focused on the thermal isoeffect concept. The non-thermal mechanism that has received the most attention is acoustically generated cavitation wherein ultrasonic energy by cavitation bubbles is concentrated. Acoustic cavitation, in a broad sense, refers to ultrasonically induced bubble activity occurring in a biological material that contains pre-existing gaseous inclusions. Cavitation-related mechanisms include radiation force, microstreaming, shock waves, free radicals, microjets and strain. It is more challenging to deduce the causes of mechanical effects in tissues that do not contain gas bodies. These ultrasonic biophysics mechanisms will be discussed in the context of diagnostic ultrasound exposure risk concerns.
Collapse
|
Research Support, N.I.H., Extramural |
18 |
438 |
4
|
Pitsillides CM, Joe EK, Wei X, Anderson RR, Lin CP. Selective cell targeting with light-absorbing microparticles and nanoparticles. Biophys J 2003; 84:4023-32. [PMID: 12770906 PMCID: PMC1302982 DOI: 10.1016/s0006-3495(03)75128-5] [Citation(s) in RCA: 395] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
We describe a new method for selective cell targeting based on the use of light-absorbing microparticles and nanoparticles that are heated by short laser pulses to create highly localized cell damage. The method is closely related to chromophore-assisted laser inactivation and photodynamic therapy, but is driven solely by light absorption, without the need for photochemical intermediates (particularly singlet oxygen). The mechanism of light-particle interaction was investigated by nanosecond time-resolved microscopy and by thermal modeling. The extent of light-induced damage was investigated by cell lethality, by cell membrane permeability, and by protein inactivation. Strong particle size dependence was found for these interactions. A technique based on light to target endogenous particles is already being exploited to treat pigmented cells in dermatology and ophthalmology. With exogenous particles, phamacokinetics and biodistribution studies are needed before the method can be evaluated against photodynamic therapy for cancer treatment. However, particles are unique, unlike photosensitizers, in that they can remain stable and inert in cells for extended periods. Thus they may be particularly useful for prelabeling cells in engineered tissue before implantation. Subsequent irradiation with laser pulses will allow control of the implanted cells (inactivation or modulation) in a noninvasive manner.
Collapse
|
research-article |
22 |
395 |
5
|
Jorgensen PL, Hakansson KO, Karlish SJD. Structure and mechanism of Na,K-ATPase: functional sites and their interactions. Annu Rev Physiol 2003; 65:817-49. [PMID: 12524462 DOI: 10.1146/annurev.physiol.65.092101.142558] [Citation(s) in RCA: 394] [Impact Index Per Article: 17.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The cell membrane Na,K-ATPase is a member of the P-type family of active cation transport proteins. Recently the molecular structure of the related sarcoplasmic reticulum Ca-ATPase in an E1 conformation has been determined at 2.6 A resolution. Furthermore, theoretical models of the Ca-ATPase in E2 conformations are available. As a result of these developments, these structural data have allowed construction of homology models that address the central questions of mechanism of active cation transport by all P-type cation pumps. This review relates recent evidence on functional sites of Na,K-ATPase for the substrate (ATP), the essential cofactor (Mg(2+) ions), and the transported cations (Na(+) and K(+)) to the molecular structure. The essential elements of the Ca-ATPase structure, including 10 transmembrane helices and well-defined N, P, and A cytoplasmic domains, are common to all PII-type pumps such as Na,K-ATPase and H,K-ATPases. However, for Na,K-ATPase and H,K-ATPase, which consist of both alpha- and beta-subunits, there may be some detailed differences in regions of subunit interactions. Mutagenesis, proteolytic cleavage, and transition metal-catalyzed oxidative cleavages are providing much evidence about residues involved in binding of Na(+), K(+), ATP, and Mg(2+) ions and changes accompanying E1-E2 or E1-P-E2-P conformational transitions. We discuss this evidence in relation to N, P, and A cytoplasmic domain interactions, and long-range interactions between the active site and the Na(+) and K(+) sites in the transmembrane segments, for the different steps of the catalytic cycle.
Collapse
|
Review |
22 |
394 |
6
|
Decker MJ, Torry MR, Wyland DJ, Sterett WI, Richard Steadman J. Gender differences in lower extremity kinematics, kinetics and energy absorption during landing. Clin Biomech (Bristol, Avon) 2003; 18:662-9. [PMID: 12880714 DOI: 10.1016/s0268-0033(03)00090-1] [Citation(s) in RCA: 386] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVE To determine whether gender differences exist in lower extremity joint motions and energy absorption landing strategies between age and skill matched recreational athletes. DESIGN Mixed factor, repeated measures design. BACKGROUND Compared to males, females execute high demand activities in a more erect posture potentially predisposing the anterior cruciate ligament to greater loads and injury. The preferred energy absorption strategy may provide insight for this performance difference. METHODS Inverse dynamic solutions estimated lower extremity joint kinematics, kinetics and energetic profiles for twelve males and nine females performing a 60 cm drop landing. RESULTS Females demonstrated a more erect landing posture and utilized greater hip and ankle joint range of motions and maximum joint angular velocities compared to males. Females also exhibited greater energy absorption and peak powers from the knee extensors and ankle plantar-flexors compared to the males. Examinations of the energy absorption contributions revealed that the knee was the primary shock absorber for both genders, whereas the ankle plantar-flexors muscles was the second largest contributor to energy absorption for the females and the hip extensors muscles for the males. CONCLUSIONS Females may choose to land in a more erect posture to maximize the energy absorption from the joints most proximal to ground contact. RELEVANCE Females may be at a greater risk to anterior cruciate ligament injury during landing due to their energy absorption strategy.
Collapse
|
Clinical Trial |
22 |
386 |
7
|
Nakamura Y, Aratani N, Osuka A. Cyclic porphyrin arrays as artificial photosynthetic antenna: synthesis and excitation energy transfer. Chem Soc Rev 2007; 36:831-45. [PMID: 17534471 DOI: 10.1039/b618854k] [Citation(s) in RCA: 325] [Impact Index Per Article: 18.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Covalently linked cyclic porphyrin arrays have been explored in recent years as artificial photosynthetic antenna. In this review we present the fundamental aspects of covalently linked cyclic porphyrin arrays by highlighting recent progress. The major emphasis of this tutorial review lies on the synthetic method, the structure, and the excitation energy transfer (EET) of such arrays. The final cyclization steps were often performed with the aid of templates. Efficient EET along the wheel is observed in these cyclic arrays, but ultrafast EET processes with rates of <1 ps, which rival those in the natural LH2, are rare and have been identified only in cyclic arrays 30-32 composed of directly meso-meso linked porphyrins.
Collapse
|
|
18 |
325 |
8
|
Rabaey K, Lissens G, Siciliano SD, Verstraete W. A microbial fuel cell capable of converting glucose to electricity at high rate and efficiency. Biotechnol Lett 2004; 25:1531-5. [PMID: 14571978 DOI: 10.1023/a:1025484009367] [Citation(s) in RCA: 315] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A microbial fuel cell containing a mixed bacterial culture utilizing glucose as carbon source was enriched to investigate power output in relation to glucose dosage. Electron recovery in terms of electricity up to 89% occurred for glucose feeding rates in the range 0.5-3 g l(-1) d(-1), at powers up to 3.6 W m(-2) of electrode surface, a five fold higher power output than reported thus far. This research indicates that microbial electricity generation offers perspectives for optimization.
Collapse
|
Journal Article |
21 |
315 |
9
|
Macaluso A, De Vito G. Muscle strength, power and adaptations to resistance training in older people. Eur J Appl Physiol 2003; 91:450-72. [PMID: 14639481 DOI: 10.1007/s00421-003-0991-3] [Citation(s) in RCA: 314] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/04/2003] [Indexed: 12/25/2022]
Abstract
Muscle strength and, to a greater extent, power inexorably decline with ageing. Quantitative loss of muscle mass, referred to as "sarcopenia", is the most important factor underlying this phenomenon. However, qualitative changes of muscle fibres and tendons, such as selective atrophy of fast-twitch fibres and reduced tendon stiffness, and neural changes, such as lower activation of the agonist muscles and higher coactivation of the antagonist muscles, also account for the age-related decline in muscle function. The selective atrophy of fast-twitch fibres has been ascribed to the progressive loss of motoneurons in the spinal cord with initial denervation of fast-twitch fibres, which is often accompanied by reinnervation of these fibres by axonal sprouting from adjacent slow-twitch motor units (MUs). In addition, single fibres of older muscles containing myosin heavy chains of both type I and II show lower tension and shortening velocity with respect to the fibres of young muscles. Changes in central activation capacity are still controversial. At the peripheral level, the rate of decline in parameters of the surface-electromyogram power spectrum and in the action-potential conduction velocity has been shown to be lower in older muscle. Therefore, the older muscle seems to be more resistant to isometric fatigue (fatigue-paradox), which can be ascribed to the selective atrophy of fast-twitch fibres, slowing in the contractile properties and lower MU firing rates. Finally, specific training programmes can dramatically improve the muscle strength, power and functional abilities of older individuals, which will be examined in the second part of this review.
Collapse
|
Review |
22 |
314 |
10
|
Ishikawa M, Komi PV, Grey MJ, Lepola V, Bruggemann GP. Muscle-tendon interaction and elastic energy usage in human walking. J Appl Physiol (1985) 2005; 99:603-8. [PMID: 15845776 DOI: 10.1152/japplphysiol.00189.2005] [Citation(s) in RCA: 289] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The present study was designed to explore how the interaction between the fascicles and tendinous tissues is involved in storage and utilization of elastic energy during human walking. Eight male subjects walked with a natural cadence (1.4 ± 0.1 m/s) on a 10-m-long force plate system. In vivo techniques were employed to record the Achilles tendon force and to scan real-time fascicle lengths for two muscles (medial gastrocnemius and soleus). The results showed that tendinous tissues of both medial gastrocnemius and soleus muscles lengthened slowly throughout the single-stance phase and then recoiled rapidly close to the end of the ground contact. However, the fascicle length changes demonstrated different patterns and amplitudes between two muscles. The medial gastrocnemius fascicles were stretched during the early single-stance phase and then remained isometrically during the late-stance phase. In contrast, the soleus fascicles were lengthened until the end of the single-stance phase. These findings suggest that the elastic recoil takes place not as a spring-like bouncing but as a catapult action in natural human walking. The interaction between the muscle fascicles and tendinous tissues plays an important role in the process of release of elastic energy, although the leg muscles, which are commonly accepted as synergists, do not have similar mechanical behavior of fascicles in this catapult action.
Collapse
|
|
20 |
289 |
11
|
Rye HS, Roseman AM, Chen S, Furtak K, Fenton WA, Saibil HR, Horwich AL. GroEL-GroES cycling: ATP and nonnative polypeptide direct alternation of folding-active rings. Cell 1999; 97:325-38. [PMID: 10319813 DOI: 10.1016/s0092-8674(00)80742-4] [Citation(s) in RCA: 247] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The double-ring chaperonin GroEL mediates protein folding in the central cavity of a ring bound by ATP and GroES, but it is unclear how GroEL cycles from one folding-active complex to the next. We observe that hydrolysis of ATP within the cis ring must occur before either nonnative polypeptide or GroES can bind to the trans ring, and this is associated with reorientation of the trans ring apical domains. Subsequently, formation of a new cis-ternary complex proceeds on the open trans ring with polypeptide binding first, which stimulates the ATP-dependent dissociation of the cis complex (by 20- to 50-fold), followed by GroES binding. These results indicate that, in the presence of nonnative protein, GroEL alternates its rings as folding-active cis complexes, expending only one round of seven ATPs per folding cycle.
Collapse
|
|
26 |
247 |
12
|
Abstract
An essential requirement for successful radiation therapy is that the discrepancies between dose distributions calculated at the treatment planning stage and those delivered to the patient are minimized. An important component in the treatment planning process is the accurate calculation of dose distributions. The most accurate way to do this is by Monte Carlo calculation of particle transport, first in the geometry of the external or internal source followed by tracking the transport and energy deposition in the tissues of interest. Additionally, Monte Carlo simulations allow one to investigate the influence of source components on beams of a particular type and their contaminant particles. Since the mid 1990s, there has been an enormous increase in Monte Carlo studies dealing specifically with the subject of the present review, i.e., external photon beam Monte Carlo calculations, aided by the advent of new codes and fast computers. The foundations for this work were laid from the late 1970s until the early 1990s. In this paper we will review the progress made in this field over the last 25 years. The review will be focused mainly on Monte Carlo modelling of linear accelerator treatment heads but sections will also be devoted to kilovoltage x-ray units and 60Co teletherapy sources.
Collapse
|
|
22 |
240 |
13
|
Abstract
The TonB system of Gram-negative bacteria appears to exist for the purpose of transducing the protonmotive force energy from the cytoplasmic membrane, where it is generated, to the outer membrane, where it is needed for active transport of iron siderophores, vitamin B12 and, in pathogens, iron from host-binding proteins. In this review, we bring the reader up to date on the developments in the field since the authors each wrote reviews in this journal in 1990.
Collapse
|
Review |
22 |
231 |
14
|
Tucker R, Marle T, Lambert EV, Noakes TD. The rate of heat storage mediates an anticipatory reduction in exercise intensity during cycling at a fixed rating of perceived exertion. J Physiol 2006; 574:905-15. [PMID: 16497719 PMCID: PMC1817748 DOI: 10.1113/jphysiol.2005.101733] [Citation(s) in RCA: 224] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
The aim of the present study was to examine the regulation of exercise intensity in hot environments when exercise is performed at a predetermined, fixed subjective rating of perceived exertion (RPE). Eight cyclists performed cycling trials at 15 degrees C (COOL), 25 degrees C (NORM) and 35 degrees C (HOT) (65% humidity throughout), during which they were instructed to cycle at a Borg rating of perceived exertion (RPE) of 16, increasing or decreasing their power output in order to maintain this RPE. Power output declined linearly in all three trials and the rate of decline was significantly higher in HOT than in NORM and COOL (2.35 +/- 0.73 W min(-1), 1.63 +/- 0.70 and 1.61 +/- 0.80 W min(-1), respectively, P < 0.05). The rate of heat storage was significantly higher in HOT for the first 4 min of the trials only, as a result of increasing skin temperatures. Thereafter, no differences in heat storage were found between conditions. We conclude that the regulation of exercise intensity is controlled by an initial afferent feedback regarding the rate of heat storage, which is used to regulate exercise intensity and hence the rate of heat storage for the remainder of the anticipated exercise bout. This regulation maintains thermal homeostasis by reducing the exercise work rate and utilizing the subjective RPE specifically to ensure that excessive heat accumulation does not occur and cellular catastrophe is avoided.
Collapse
|
Research Support, Non-U.S. Gov't |
19 |
224 |
15
|
Duan HG, Prokhorenko VI, Cogdell RJ, Ashraf K, Stevens AL, Thorwart M, Miller RJD. Nature does not rely on long-lived electronic quantum coherence for photosynthetic energy transfer. Proc Natl Acad Sci U S A 2017; 114:8493-8498. [PMID: 28743751 PMCID: PMC5559008 DOI: 10.1073/pnas.1702261114] [Citation(s) in RCA: 192] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
During the first steps of photosynthesis, the energy of impinging solar photons is transformed into electronic excitation energy of the light-harvesting biomolecular complexes. The subsequent energy transfer to the reaction center is commonly rationalized in terms of excitons moving on a grid of biomolecular chromophores on typical timescales [Formula: see text]100 fs. Today's understanding of the energy transfer includes the fact that the excitons are delocalized over a few neighboring sites, but the role of quantum coherence is considered as irrelevant for the transfer dynamics because it typically decays within a few tens of femtoseconds. This orthodox picture of incoherent energy transfer between clusters of a few pigments sharing delocalized excitons has been challenged by ultrafast optical spectroscopy experiments with the Fenna-Matthews-Olson protein, in which interference oscillatory signals up to 1.5 ps were reported and interpreted as direct evidence of exceptionally long-lived electronic quantum coherence. Here, we show that the optical 2D photon echo spectra of this complex at ambient temperature in aqueous solution do not provide evidence of any long-lived electronic quantum coherence, but confirm the orthodox view of rapidly decaying electronic quantum coherence on a timescale of 60 fs. Our results can be considered as generic and give no hint that electronic quantum coherence plays any biofunctional role in real photoactive biomolecular complexes. Because in this structurally well-defined protein the distances between bacteriochlorophylls are comparable to those of other light-harvesting complexes, we anticipate that this finding is general and directly applies to even larger photoactive biomolecular complexes.
Collapse
|
research-article |
8 |
192 |
16
|
Fassioli F, Dinshaw R, Arpin PC, Scholes GD. Photosynthetic light harvesting: excitons and coherence. J R Soc Interface 2014; 11:20130901. [PMID: 24352671 PMCID: PMC3899860 DOI: 10.1098/rsif.2013.0901] [Citation(s) in RCA: 184] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Accepted: 11/29/2013] [Indexed: 12/15/2022] Open
Abstract
Photosynthesis begins with light harvesting, where specialized pigment-protein complexes transform sunlight into electronic excitations delivered to reaction centres to initiate charge separation. There is evidence that quantum coherence between electronic excited states plays a role in energy transfer. In this review, we discuss how quantum coherence manifests in photosynthetic light harvesting and its implications. We begin by examining the concept of an exciton, an excited electronic state delocalized over several spatially separated molecules, which is the most widely available signature of quantum coherence in light harvesting. We then discuss recent results concerning the possibility that quantum coherence between electronically excited states of donors and acceptors may give rise to a quantum coherent evolution of excitations, modifying the traditional incoherent picture of energy transfer. Key to this (partially) coherent energy transfer appears to be the structure of the environment, in particular the participation of non-equilibrium vibrational modes. We discuss the open questions and controversies regarding quantum coherent energy transfer and how these can be addressed using new experimental techniques.
Collapse
|
Review |
11 |
184 |
17
|
Abstract
F1-ATPase is a rotary motor made of a single protein molecule. Its rotation is driven by free energy obtained by ATP hydrolysis. In vivo, another motor, Fo, presumably rotates the F1 motor in the reverse direction, reversing also the chemical reaction in F1 to let it synthesize ATP. Here we attempt to answer two related questions, How is free energy obtained by ATP hydrolysis converted to the mechanical work of rotation, and how is mechanical work done on F1 converted to free energy to produce ATP? After summarizing single-molecule observations of F1 rotation, we introduce a toy model and discuss its free-energy diagrams to possibly answer the above questions. We also discuss the efficiency of molecular motors in general.
Collapse
|
Review |
21 |
160 |
18
|
Hedderich R. Energy-Converting [NiFe] Hydrogenases from Archaea and Extremophiles: Ancestors of Complex I. J Bioenerg Biomembr 2004; 36:65-75. [PMID: 15168611 DOI: 10.1023/b:jobb.0000019599.43969.33] [Citation(s) in RCA: 155] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
[NiFe] hydrogenases are well-characterized enzymes that have a key function in the H2 metabolism of various microorganisms. In the recent years a subfamily of [NiFe] hydrogenases with unique properties has been identified. The members of this family form multisubunit membrane-bound enzyme complexes composed of at least four hydrophilic and two integral membrane proteins. These six conserved subunits, which built the core of these hydrogenases, have closely related counterparts in energy-conserving NADH:quinone oxidoreductases (complex I). However, the reaction catalyzed by these hydrogenases differs significantly from the reaction catalyzed by complex I. For some of these hydrogenases the physiological role is to catalyze the reduction of H+ with electrons derived from reduced ferredoxins or poly-ferredoxins. This exergonic reaction is coupled to energy conservation by means of electron-transport phosphorylation. Other members of this hydrogenase family mainly function to provide the cell with reduced ferredoxin with H2 as electron donor in a reaction driven by reverse electron transport. As complex I these hydrogenases function as ion pumps and have therefore been designated as energy-converting [NiFe] hydrogenases.
Collapse
|
|
21 |
155 |
19
|
Grabowski A, Farley CT, Kram R. Independent metabolic costs of supporting body weight and accelerating body mass during walking. J Appl Physiol (1985) 2005; 98:579-83. [PMID: 15649878 DOI: 10.1152/japplphysiol.00734.2004] [Citation(s) in RCA: 155] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The metabolic cost of walking is determined by many mechanical tasks, but the individual contribution of each task remains unclear. We hypothesized that the force generated to support body weight and the work performed to redirect and accelerate body mass each individually incur a significant metabolic cost during normal walking. To test our hypothesis, we measured changes in metabolic rate in response to combinations of simulated reduced gravity and added loading. We found that reducing body weight by simulating reduced gravity modestly decreased net metabolic rate. By calculating the metabolic cost per Newton of reduced body weight, we deduced that generating force to support body weight comprises approximately 28% of the metabolic cost of normal walking. Similar to previous loading studies, we found that adding both weight and mass increased net metabolic rate in more than direct proportion to load. However, when we added mass alone by using a combination of simulated reduced gravity and added load, net metabolic rate increased about one-half as much as when we added both weight and mass. By calculating the cost per kilogram of added mass, we deduced that the work performed on the center of mass comprises approximately 45% of the metabolic cost of normal walking. Our findings support the hypothesis that force and work each incur a significant metabolic cost. Specifically, the cost of performing work to redirect and accelerate the center of mass is almost twice as great as the cost of generating force to support body weight.
Collapse
|
Research Support, U.S. Gov't, P.H.S. |
20 |
155 |
20
|
Bai P, Zhu G, Lin ZH, Jing Q, Chen J, Zhang G, Ma J, Wang ZL. Integrated multilayered triboelectric nanogenerator for harvesting biomechanical energy from human motions. ACS NANO 2013; 7:3713-9. [PMID: 23484470 DOI: 10.1021/nn4007708] [Citation(s) in RCA: 153] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
We demonstrate a new flexible multilayered triboelectric nanogenerator (TENG) with extremely low cost, simple structure, small size (3.8 cm×3.8 cm×0.95 cm) and lightweight (7 g) by innovatively integrating five layers of units on a single flexible substrate. Owing to the unique structure and nanopore-based surface modification on the metal surface, the instantaneous short-circuit current (Isc) and the open-circuit voltage (Voc) could reach 0.66 mA and 215 V with an instantaneous maximum power density of 9.8 mW/cm2 and 10.24 mW/cm3. This is the first 3D integrated TENG for enhancing the output power. Triggered by press from normal walking, the TENG attached onto a shoe pad was able to instantaneously drive multiple commercial LED bulbs. With the flexible structure, the TENG can be further integrated into clothes or even attached onto human body without introducing sensible obstruction and discomfort to human motions. The novel design of TENG demonstrated here can be applied to potentially achieve self-powered portable electronics.
Collapse
|
|
12 |
153 |
21
|
Cormie P, McBride JM, McCaulley GO. Validation of Power Measurement Techniques in Dynamic Lower Body Resistance Exercises. J Appl Biomech 2007; 23:103-18. [PMID: 17603130 DOI: 10.1123/jab.23.2.103] [Citation(s) in RCA: 153] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The objective of this study was to investigate the validity of power measurement techniques utilizing various kinematic and kinetic devices during the jump squat (JS), squat (S) and power clean (PC). Ten Division I male athletes were assessed for power output across various intensities: 0, 12, 27, 42, 56, 71, and 85% of one repetition maximum strength (1RM) in the JS and S and 30, 40, 50, 60, 70, 80, and 90% of 1RM in the PC. During the execution of each lift, six different data collection systems were utilized; (1) one linear position transducer (1-LPT); (2) one linear position transducer with the system mass representing the force (1-LPT+MASS); (3) two linear position transducers (2-LPT); (4) the force plate (FP); (5) one linear position transducer and a force plate (1-LPT+FP); (6) two linear position transducers and a force place (2-LPT+FP). Kinetic and kinematic variables calculated using the six methodologies were compared. Vertical power, force, and velocity differed significantly between 2-LPT+FP and 1-LPT, 1-LPT+MASS, 2-LPT, and FP methodologies across various intensities throughout the JS, S, and PC. These differences affected the load–power relationship and resulted in the transfer of the optimal load to a number of different intensities. This examination clearly indicates that data collection and analysis procedures influence the power output calculated as well as the load–power relationship of dynamic lower body movements.
Collapse
|
|
18 |
153 |
22
|
Abstract
Based upon the optimal control solutions to a maximum-height countermovement jump (CMJ) and a maximum-height squat jump (SJ), this paper provides a quantitative description of how tendons and the elastic elements of muscle store and deliver energy during vertical jumping. After confirming the ability of the model to replicate the major features of each jump (i.e. muscle activation patterns, body-segmental motions, ground reaction forces, jump height, and total ground contact time), the time histories of the forces and shortening velocities of all the musculotendon actuators in the model were used to calculate the work done on the skeleton by tendons as well as the series-elastic elements, the parallel-elastic elements, and the contractile elements of muscle. We found that all the elastic tissues delivered nearly the same amount of energy to the skeleton during a CMJ and an SJ. The reason is twofold: first, nearly as much elastic strain energy was stored during the SJ as the CMJ; second, more stored elastic strain energy was lost as heat during the CMJ. There was also a difference in the way energy was stored during each jump. During the CMJ, strain energy stored in the elastic tissues came primarily from the gravitational potential energy of the skeleton as the more proximal extensor muscles were stretched during the downward phase of the jump. During the SJ, on the other hand, energy stored in the elastic tissues came primarily from the contractile elements as they did work to stretch the tendons and the series-elastic elements of the muscles. Increasing tendon compliance in the model led to an increase in elastic energy storage and utilization, but it also decreased the amount of energy delivered by the contractile elements to the skeleton. Jump height therefore remained almost the same for both jumps. These results suggest that elastic energy storage and utilization enhance jumping efficiency much more than overall jumping performance.
Collapse
|
|
32 |
153 |
23
|
Thomson SL, Mongeau L, Frankel SH. Aerodynamic transfer of energy to the vocal folds. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 118:1689-700. [PMID: 16240827 DOI: 10.1121/1.2000787] [Citation(s) in RCA: 151] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The aerodynamic transfer of energy from glottal airflow to vocal fold tissue during phonation was explored using complementary synthetic and numerical vocal fold models. The synthetic model was fabricated using a flexible polyurethane rubber compound. The model size, shape, and material properties were generally similar to corresponding human vocal fold characteristics. Regular, self-sustained oscillations were achieved at a frequency of approximately 120 Hz. The onset pressure was approximately 1.2 kPa. A corresponding two-dimensional finite element model was developed using geometry definitions and material properties based on the synthetic model. The finite element model upstream and downstream pressure boundary conditions were based on experimental values acquired using the synthetic model. An analysis of the fully coupled fluid and solid numerical domains included flow separation and unsteady effects. The numerical results provided detailed flow data that was used to investigate aerodynamic energy transfer mechanisms. The results support the hypothesis that a cyclic variation of the orifice profile from a convergent to a divergent shape leads to a temporal asymmetry in the average wall pressure, which is the key factor for the achievement of self-sustained vocal fold oscillations. me rica.
Collapse
|
Research Support, N.I.H., Extramural |
20 |
151 |
24
|
Pringle JSM, Doust JH, Carter H, Tolfrey K, Campbell IT, Sakkas GK, Jones AM. Oxygen uptake kinetics during moderate, heavy and severe intensity "submaximal" exercise in humans: the influence of muscle fibre type and capillarisation. Eur J Appl Physiol 2003; 89:289-300. [PMID: 12736837 DOI: 10.1007/s00421-003-0799-1] [Citation(s) in RCA: 149] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/30/2002] [Indexed: 11/25/2022]
Abstract
The purpose of the present study was to test the hypothesis that muscle fibre type influences the oxygen uptake (.VO(2)) on-kinetic response (primary time constant; primary and slow component amplitudes) during moderate, heavy and severe intensity sub-maximal cycle exercise. Fourteen subjects [10 males, mean (SD) age 25 (4) years; mass 72.6 (3.9) kg; .VO(2peak) 47.9 (2.3) ml kg(-1) min(-1)] volunteered to participate in this study. The subjects underwent a muscle biopsy of the vastus lateralis for histochemical determination of muscle fibre type, and completed repeat "square-wave" transitions from unloaded cycling to power outputs corresponding to 80% of the ventilatory threshold (VT; moderate exercise), 50% (heavy exercise) and 70% (severe exercise) of the difference between the VT and .VO(2peak). Pulmonary .VO(2) was measured breath-by-breath. The percentage of type I fibres was significantly correlated with the time constant of the primary .VO(2) response for heavy exercise (r=-0.68). Furthermore, the percentage of type I muscle fibres was significantly correlated with the gain of the .VO(2) primary component for moderate (r=0.65), heavy (r=0.57) and severe (r=0.57) exercise, and with the relative amplitude of the .VO(2) slow component for heavy (r=-0.74) and severe (r=-0.64) exercise. The influence of muscle fibre type on the .VO(2) on-kinetic response persisted when differences in aerobic fitness and muscle capillarity were accounted for. This study demonstrates that muscle fibre type is significantly related to both the speed and the amplitudes of the .VO(2) response at the onset of constant-load sub-maximal exercise. Differences in contraction efficiency and oxidative enzyme activity between type I and type II muscle fibres may be responsible for the differences observed.
Collapse
|
Clinical Trial |
22 |
149 |
25
|
Samozino P, Morin JB, Hintzy F, Belli A. A simple method for measuring force, velocity and power output during squat jump. J Biomech 2008; 41:2940-5. [PMID: 18789803 DOI: 10.1016/j.jbiomech.2008.07.028] [Citation(s) in RCA: 146] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2008] [Revised: 06/05/2008] [Accepted: 07/27/2008] [Indexed: 11/16/2022]
Abstract
Our aim was to clarify the relationship between power output and the different mechanical parameters influencing it during squat jumps, and to further use this relationship in a new computation method to evaluate power output in field conditions. Based on fundamental laws of mechanics, computations were developed to express force, velocity and power generated during one squat jump. This computation method was validated on eleven physically active men performing two maximal squat jumps. During each trial, mean force, velocity and power were calculated during push-off from both force plate measurements and the proposed computations. Differences between the two methods were not significant and lower than 3% for force, velocity and power. The validity of the computation method was also highlighted by Bland and Altman analyses and linear regressions close to the identity line (P<0.001). The low coefficients of variation between two trials demonstrated the acceptable reliability of the proposed method. The proposed computations confirmed, from a biomechanical analysis, the positive relationship between power output, body mass and jump height, hitherto only shown by means of regression-based equations. Further, these computations pointed out that power also depends on push-off vertical distance. The accuracy and reliability of the proposed theoretical computations were in line with those observed when using laboratory ergometers such as force plates. Consequently, the proposed method, solely based on three simple parameters (body mass, jump height and push-off distance), allows to accurately evaluate force, velocity and power developed by lower limbs extensor muscles during squat jumps in field conditions.
Collapse
|
Journal Article |
17 |
146 |