1
|
Efficacy of vibrant sound bridge in congenital aural atresia: an updated systematic review. Eur Arch Otorhinolaryngol 2024; 281:2849-2859. [PMID: 38647685 DOI: 10.1007/s00405-024-08629-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Accepted: 03/19/2024] [Indexed: 04/25/2024]
Abstract
PURPOSE The indications of Vibrant Soundbridge (VSB) have been expanded to include patients with conductive and mixed hearing loss due to congenital aural atresia (CAA). However, the current evidence supporting the auditory outcomes of VSB is based mainly on case reports and retrospective chart reviews. Therefore, the present systematic review aims to summarize and critically appraise the current evidence regarding the safety and effectiveness of VSB in children and adult patients with CAA. METHODS A systematic literature search retrieved studies that evaluated the outcomes of unilateral or bilateral implantation of VSB in patients with CAA. The bibliographic search was conducted in PubMed, Scopus, EBSCO, and Cochrane Central Register of Controlled Trials (CENTRAL) databases from January 2000 to December 2022. RESULTS Twenty-seven studies were included in the present systematic review. Overall, the speech perception after VSB was good, with a mean word recognition score (WRS) score ranging from 60 to 96.7%. The mean postoperative speech recognition threshold (SRT) after implantation ranged from 20.8 to 50 dB. The effective gain was reported in 15 studies, ranging from 31.3 to 45.5 dB. In terms of user satisfaction with VSB, the included studies showed significant improvements in the patient-reported outcomes, such as the Speech Spatial and Qualities of Hearing scale and Glasgow Hearing Aid Benefit Profile. The VSB implantation was generally safe with low incidence of postoperative complications. CONCLUSION VSB provides significant benefits to individuals with hearing loss owing to CAA, with very good subjective outcomes and a low risk of complications.
Collapse
|
2
|
Stapedotomy Versus Cochlear Implantation for Far Advanced Otosclerosis: Insights From a Patient With Matched Preoperative and Postoperative Function. Otol Neurotol 2024; 45:e381-e384. [PMID: 38728553 DOI: 10.1097/mao.0000000000004197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/12/2024]
Abstract
OBJECTIVE To examine patient preference after stapedotomy versus cochlear implantation in a unique case of a patient with symmetrical profound mixed hearing loss and similar postoperative speech perception improvement. PATIENTS An adult patient with bilateral symmetrical far advanced otosclerosis, with profound mixed hearing loss. INTERVENTION Stapedotomy in the left ear, cochlear implantation in the right ear. MAIN OUTCOME MEASURE Performance on behavioral audiometry, and subjective report of hearing and intervention preference. RESULTS A patient successfully underwent left stapedotomy and subsequent cochlear implantation on the right side, per patient preference. Preoperative audiometric characteristics were similar between ears (pure-tone average [PTA] [R: 114; L: 113 dB]; word recognition score [WRS]: 22%). Postprocedural audiometry demonstrated significant improvement after stapedotomy (PTA: 59 dB, WRS: 75%) and from cochlear implant (PTA: 20 dB, WRS: 60%). The patient subjectively reported a preference for the cochlear implant ear despite having substantial gains from stapedotomy. A nuanced discussion highlighting potentially overlooked benefits of cochlear implants in far advanced otosclerosis is conducted. CONCLUSION In comparison with stapedotomy and hearing aids, cochlear implantation generally permits greater access to sound among patients with far advanced otosclerosis. Though the cochlear implant literature mainly focuses on speech perception outcomes, an underappreciated benefit of cochlear implantation is the high likelihood of achieving "normal" sound levels across the audiogram.
Collapse
|
3
|
Binaural hearing in monaural conductive or mixed hearing loss fitted with unilateral Bonebridge. ACTA OTORHINOLARYNGOLOGICA ITALICA : ORGANO UFFICIALE DELLA SOCIETA ITALIANA DI OTORINOLARINGOLOGIA E CHIRURGIA CERVICO-FACCIALE 2024; 44:113-119. [PMID: 38651553 DOI: 10.14639/0392-100x-n2752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 11/13/2023] [Indexed: 04/25/2024]
Abstract
Objective To determine the benefits of binaural hearing rehabilitation in patients with monaural conductive or mixed hearing loss treated with a unilateral bone conduction implant (BCI). Methods This monocentric study includes 7 patients with monaural conductive or mixed hearing loss who underwent surgical implantation of a unilateral BCI (Bonebridge, Med-El). An ITA Matrix test was performed by each patient included in the study - without and with the BCI and in three different settings - to determine the summation effect, squelch effect and head shadow effect. Subjective hearing benefits were assessed using the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire. Results The difference in signal to noise ratio of patients without and with BCI was 0.79 dB in the summation setting (p < 0.05), 4.62 dB in the head shadow setting (p < 0.05) and 1.53 dB (p = 0.063) in the squelch setting. The APHAB questionnaire revealed a subjective discomfort in the presence of unexpected sounds in patients using a unilateral BCI (aversiveness score) compared to the same environmental situations without BCI, with a mean discomfort score of 69.00% (SD ± 21.24%) with monaural BCI versus 25.67% (SD ± 16.70%) without BCI (difference: -43.33%, p < 0.05). In terms of global score, patients wearing a unilateral Bonebridge implant did not show any significant differences compared to those without hearing aid (difference: -4.00%, p = 0.310). Conclusions Our study shows that the use of a unilateral BCI in patients affected by monaural conductive or mixed hearing loss can improve speech perception under noise conditions due to the summation effect and to the decrease of the head shadow effect. However, since monaural BCIs might lead to discomfort under noise conditions in some subjects, a pre-operative assessment of the possible individual benefit of a monaural BCI should be carried out in patients affected by unilateral conductive or mixed hearing loss in order to investigate the possible additional effect of the fitting of hearing aids.
Collapse
|
4
|
Clinical performance, safety, and patient-reported outcomes of an active osseointegrated bone-conduction hearing implant system at 24-month follow-up. Eur Arch Otorhinolaryngol 2024; 281:683-691. [PMID: 37552281 PMCID: PMC10796683 DOI: 10.1007/s00405-023-08133-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 07/13/2023] [Indexed: 08/09/2023]
Abstract
PURPOSE To investigate 2-year post-operative hearing performance, safety, and patient-reported outcomes of hearing-impaired adults treated with the Osia® 2 System, an active osseointegrated bone-conduction hearing implant that uses piezoelectric technology. METHODS A prospective, multicenter, open-label, single-arm, within-subject clinical study conducted at three tertiary referral clinical centers located in Melbourne, Sydney and Hong Kong. Twenty adult recipients of the Osia 2 System were enrolled and followed up between 12 and 24 months post-implantation: 17 with mixed or conductive hearing loss and 3 with single-sided sensorineural deafness. Safety data, audiological thresholds, speech recognition thresholds in noise, and patient-reported outcomes were collected and evaluated. In addition, pre-and 6-month post-implantation data were collected retrospectively for this recipient cohort enrolled into the earlier study (ClinicalTrials.gov NCT04041700). RESULTS Between 6- and 24-month follow-up, there was no statistically significant change in free-field hearing thresholds or speech reception thresholds in noise (p = > 0.05), indicating that aided improvements were maintained up to 24 months of follow-up. Furthermore, improvements in health-related quality of life and daily hearing ability, as well as clinical and subjective measures of hearing benefit remained stable over the 24-month period. No serious adverse events were reported during extended follow-up. CONCLUSIONS These study results provide further evidence to support the longer term clinical safety, hearing performance, and patient-related benefits of the Osia 2 System in patients with either a conductive hearing loss, mixed hearing loss, or single-sided sensorineural deafness. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT04754477. First posted: February 15, 2021.
Collapse
|
5
|
The influence of intraoperative auditory brainstem responses on vibroplasty coupling-quality and analysis of the impact of different fixation steps on the coupling. Eur Arch Otorhinolaryngol 2024; 281:141-151. [PMID: 37442819 PMCID: PMC10764396 DOI: 10.1007/s00405-023-08103-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 06/30/2023] [Indexed: 07/15/2023]
Abstract
PURPOSE The Vibrant Soundbridge (VSB) is an established active-middle-ear-implant for patients with moderate-to-profound hearing-loss. This surgery is referred to as "Vibroplasty". Sufficient transfer of the VSB's floating-mass-transducers (FMT) energy to the inner ear is a crucial factor influencing the coupling-quality (CQ). However, assessing CQ is hamper by two issues: the method of CQ-assessment itself and the method of FMT-fixation during Vibroplasty. METHODS This prospective study explored the influence of intraoperative auditory-brainstem-response (+ ABR) measurements and various fixation methods on postoperative CQ after Vibroplasty as compared to matched-patients after Vibroplasty without intraoperative ABR (-ABR). Propensity-score-matching was performed based on preoperative bone-conduction-pure-tone-average-3 (BC-PTA3) at 1-, 2- and 4 kHz. Primary outcome parameters were postoperative CQ-PTA3, intraoperative ABR threshold for various fixation methods and postoperative BC-PTA3. RESULTS A total of 28 patients were included, of which 14 were + ABR. Preoperative BC-PTA3, sex, age, and number of previous surgeries did not differ significantly between groups (all p > 0.301). Mean postoperative CQ-PTA3 was significantly better for + ABR (1.8 vs. 12.3 dB-HL; p = 0.006). Mean intraoperative ABR threshold was superior for cartilage-counter-bearing and cartilage-housing compared to additional fixation with injectable-platelet-rich- fibrin (53 vs. 56 & 57 dB-HL, respectively; p = 0.04; η2 = 0.33). Mean postoperative BC-PTA3 did not significantly differ between patients (41.4 vs. 41.8 dB-HL; p = 0.77). A total of 7% of the patients required intraoperative readjustment of the FMT based on unsatisfactory intraoperative ABR threshold. CONCLUSION Intraoperative ABR measurement resulted in significantly better postoperative CQ. Cartilage-counter-bearing and cartilage-housing were observed to have superior CQ. A total of 7% of the patients could be spared revision-Vibroplasty due to intraoperative ABR measurement.
Collapse
|
6
|
Long-Term Follow-Up in Active Transcutaneous Bone Conduction Implants. Otol Neurotol 2024; 45:58-64. [PMID: 38085764 DOI: 10.1097/mao.0000000000004057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
OBJECTIVE To evaluate long-term outcomes of active transcutaneous bone conduction implants (atBCIs) regarding safety, hearing, and quality of life. STUDY DESIGN A clinical study with retrospective medical record analysis combined with prospective audiometry and quality of life questionnaires. SETTING Three secondary to tertiary care hospitals. PATIENTS All subjects operated with an atBCI in three regions in Sweden were asked for informed consent. Indications for atBCI were single-sided deafness (SSD) and conductive or mixed hearing loss (CMHL). INTERVENTION Evaluation of atBCI. MAIN OUTCOME MEASURES Pure tone and speech audiometry and Glasgow Benefit Inventory (GBI). RESULT Thirty-three subjects were included and 29 completed all parts. The total follow-up time was 124.1 subject-years. Nineteen subjects had CMHL and in this group, pure tone averages (PTA4) were 56.6 dB HL unaided and 29.6 dB HL aided, comparable with a functional gain of 26.0 dB. Effective gain (EG) was -12.7 dB. With bilateral hearing, Word Recognition Scores (WRS) in noise were 36.5% unaided and 59.1% aided. Fourteen subjects had SSD or asymmetric hearing loss (AHL) and in this group, PTA4 were >100 dB HL unaided and 32.1 dB HL aided with the contralateral ear blocked. EG was -9.1 dB. With bilateral hearing, WRSs were 53.2% unaided and 67.9% aided. The means of the total GBI scores were 31.7 for CMHL and 23.6 for SSD/AHL. CONCLUSION Few complications occurred during the study. The atBCI is concluded to provide a safe and effective long-term hearing rehabilitation.
Collapse
|
7
|
The Stapes Head Coupler-A Flexible and Safe Option for Vibroplasty. Otol Neurotol 2024; 45:11-17. [PMID: 38085759 DOI: 10.1097/mao.0000000000004060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
OBJECTIVE To investigate the surgical approach and the audiological outcome of a stapes head coupler in active middle ear implant surgery. STUDY DESIGN Retrospective data analysis. SETTING Tertiary referral center with a large active middle ear implant program. PATIENTS Twelve patients with active middle ear implant surgery. INTERVENTIONS Therapeutic surgical approach for hearing rehabilitation in human subjects. MAIN OUTCOME MEASURES Auditory brainstem response, sound field thresholds, vibrogram, speech perception in the Freiburger monosyllabic word test. RESULTS The stapes head was attached safely in different coupling situations. Audiological outcomes were similar to the audiological performance of established vibroplasty couplers presented in the literature. CONCLUSION The stapes head coupler is a new and safe tool for vibroplasty with a good audiological outcome.
Collapse
|
8
|
Factors associated with delayed referral and hearing rehabilitation for congenital sensorineural hearing loss. Int J Pediatr Otorhinolaryngol 2023; 175:111770. [PMID: 37890209 DOI: 10.1016/j.ijporl.2023.111770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 10/17/2023] [Accepted: 10/20/2023] [Indexed: 10/29/2023]
Abstract
OBJECTIVES To identify the impact of social determinants of health and clinical status on referral and intervention for congenital sensorineural hearing loss. STUDY DESIGN Retrospective chart review of children with confirmed sensorineural or mixed hearing loss between 2013 and 2021 at a single academic medical institution. METHODS Referral rates and timing for hearing rehabilitation, rates and timing of completed evaluation, and rate and timing of amplification were recorded. Patient demographics included gestational age, race, ethnicity, sex, hearing loss severity, and CMV status. RESULTS There were 216 children with confirmed sensorineural or mixed hearing loss, of which 77 had a unilateral hearing loss and 89 a severe or profound hearing loss. Delayed referral for hearing aid evaluation was noted in premature patients (median 375 days premature, median 147 term; p < 0.01) and publicly insured patients (median 215 days, median 123 private; p = 0.04). Delayed time to hearing aid fitting was noted for non-white patients (median 325 days, median 203 white patients; p < 0.01), publicly insured patients (median 309 days, median 212 private insurance; p < 0.02), and premature patients (median 462 days, median 224 term; p = 0.03). White patients were more likely to be referred for cochlear implant (p = 0.03).Privately insured patients and patients with a positive CMV test were more likely to be referred for cochlear implant evaluation, be seen in the cochlear implant clinic, and undergo implantation (p < 0.05). Non-white patients had a delay in cochlear implantation referral (median 928 days, median 398 days white patients; p = 0.05). Prolonged interval between evaluation in cochlear implant clinic to implantation was noted for privately insured patients (median 125 days; median 78 days publicly insured; p = 0.05). CONCLUSIONS Sociodemographic factors were significantly associated with hearing amplification referral rates and time until amplification for children with identified congenital sensorineural hearing loss. For cochlear implantation, insurance type, CMV status were significantly associated with rate and timing of cochlear implant pathway.
Collapse
|
9
|
Surgical and audiological outcomes with a new transcutaneous bone conduction device with reduced transducer thickness in children. Eur Arch Otorhinolaryngol 2023; 280:4381-4389. [PMID: 37000276 PMCID: PMC10477095 DOI: 10.1007/s00405-023-07927-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Accepted: 03/13/2023] [Indexed: 04/01/2023]
Abstract
PURPOSE Due to smaller bone thickness, young children with conductive or mixed hearing loss or single-sided deafness were previously most commonly treated with a percutaneous osseointegrated bone-anchored hearing aid (BAHA) or an active middle-ear implant. While the BAHA increases the risk of implant infections, skin infection, overgrowth of the screw or involvement of the implant in head trauma, middle-ear implant surgery involves manipulation of the ossicles with possible risk of surgical trauma. These complications can be omitted with transcutaneous bone conduction implant systems like the MED-EL Bonebridge system. The purpose of this study was to analyze whether the second generation of the Bonebridge (BCI 602) that features a decreased implant thickness with a reduced surgical drilling depth can be implanted safely in young children with good postoperative hearing performance. METHODS In this study, 14 patients under 12 years were implanted with the second generation of the Bonebridge. Preoperative workup comprised a CT scan, an MRI scan, pure tone audiometry, or alternatively a BERA (bone conduction, air conduction). Since children under 12 years often have a lower bone thickness, the CT was performed to determine the suitability of the temporal bone for optimal implant placement using the Otoplan software. RESULTS All patients (including three under the age of five) were successfully implanted and showed a good postoperative hearing performance. CONCLUSION With adequate preoperative workup, this device can be safely implanted in children and even children under 5 years of age and allows for an extension of indication criteria toward younger children.
Collapse
|
10
|
Round-Window Vibroplasty: Systematic Review and Meta-Analysis of Audiological Effectiveness With Different Round-Window Coupling Techniques. Otol Neurotol 2023; 44:e549-e559. [PMID: 37504977 DOI: 10.1097/mao.0000000000003958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/29/2023]
Abstract
OBJECTIVE Active middle ear implants can be directly coupled to the round-window (RW) membrane via RW Vibroplasty. The objectives of this systematic review were to summarize data on different RW coupling techniques and to investigate their effect on audiological and safety outcomes using meta-analyses. DATABASES REVIEWED PubMed (MEDLINE), Cochrane Library, and Embase (DIMDI). METHODS All publications reporting on audiological outcomes in human patients after RW Vibroplasty were included. Two independent reviewers carried out screening and data extraction. Meta-analyses and meta-regression were used to evaluate the potential effects of surgical and demographic parameters on primary audiological outcomes. Adverse events were extracted and tabulated for qualitative analysis. RESULTS Fourteen different combinations of surgical coupling parameters were identified in 61 included publications. Overall, data from 23 publications could be used for meta-analyses. Significantly better aided sound-field thresholds were reported for RW Vibroplasty performed without a dedicated coupler and using fascia as interponate, compared with RW Vibroplasty with an RW coupler or without an interponate. These effects were not found in other outcomes (i.e., functional gain, word recognition score). Reporting of adverse events was relatively heterogeneous, with 32 explicit mentions of revision surgery after the loss of coupling efficacy. CONCLUSION There are numerous publications investigating the effectiveness of coupling active middle ear implants to the RW membrane. However, studies are typically undersampled and of low evidence level. Using meta-analyses, weighted means, and qualitative analyses enabled a summary of the existing literature on audiological and safety outcomes after RW Vibroplasty. Individual selection of the most appropriate coupling modality with standardized intraoperative measurement and careful patient follow-up may be considered key factors for achieving effective RW coupling.
Collapse
|
11
|
Clinical performance, audiological outcomes, and quality of life of the Cochlear Osia ® system. Am J Otolaryngol 2023; 44:103951. [PMID: 37329694 DOI: 10.1016/j.amjoto.2023.103951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Accepted: 06/04/2023] [Indexed: 06/19/2023]
Abstract
OBJECTIVE The Cochlear Osseointegrated Steady-State Implant Bone Anchored Hearing Device (Osia) is a surgically implanted titanium apparatus that utilizes a piezoelectric actuator under the skin to address conductive and mixed hearing loss as well as single-sided deafness. The purpose of this study is to examine the clinical, audiologic, and quality-of-life outcomes in patients who underwent Osia implantation. METHODS This is a retrospective study analyzing 30 adult patients (age 27-86) with conductive healing loss (CHL), mixed hearing loss (MHL), or single-sided deafness (SSD) who were implanted with the Osia device from January 2020 to April 2023 at a single institution by the senior author. Preoperative speech score testing (CNC, AzBio in quiet, AzBio in noise) were performed in all subjects while unaided, wearing conventional air conduction hearing aids, and wearing a softband BAHA. These preoperative speech scores were then compared to post-implantation speech scores using paired t-test analysis to assess for degree of speech improvement. In order to analyze quality of life after Osia implantation, each patient filled out the Glasgow Benefit Inventory (GBI) survey. The GBI is a series of 18 questions answered using a five-point Likert scale that addresses the changes in general health status, physical health status, psychosocial health status, and social support after a medical intervention. RESULTS CHL, MHL, and SSD patients had significant improvement in hearing and speech recognition scores after Osia implantation compared to preoperative unaided hearing: CNC (14 % vs 80 %, p < 0.0001), AzBio in Quiet (26 % vs 94 %, p < 0.0001), and AzBio in Noise (36 % vs 87 %, p = 0.0001). Preoperative speech scores using the softband BAHA were accurate predictors of post-implantation speech scores and can serve to determine surgical candidacy for the Osia. Post-implantation Glasgow Benefit Inventory patient surveys demonstrated significant improvement in quality of life with patients scoring an average increase of +54.1 points in heath satisfaction. CONCLUSION Adult patients with CHL, MHL, and SSD can receive significant improvement in speech recognition scores after implantation with the Osia device. This translates to improved quality of life, which was confirmed on the post-implantation Glasgow Benefit Inventory patient surveys.
Collapse
|
12
|
A comparative study of audiological outcomes and compliance between the Osia system and other bone conduction hearing implants. Eur Arch Otorhinolaryngol 2023; 280:2217-2224. [PMID: 36318324 DOI: 10.1007/s00405-022-07715-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 10/18/2022] [Indexed: 04/03/2023]
Abstract
PURPOSE To examine the subjective and objective audiological benefits of the Osia system compared to devices commonly implanted prior to the introduction of this system. METHODS Osia recipients with either conductive hearing loss (CHL/MHL) (n = 9) or single-sided deafness (SSD) (n = 8) who underwent surgery from February 2021 to March 2022 were prospectively recruited. The audiological outcomes and usage rate of Osia implantees were compared with those of retrospectively recruited patients implanted with other devices (n = 50). The subjective satisfaction of the Osia implantees was also evaluated through questionnaires. RESULTS All users of the Osia system were classified as regular users. In the CHL/MHL group, the effective gain of the Osia system (11.1 ± 14.9 dB) surpassed that of the Baha and Bonebridge (- 2.7 ± 12.6 dB) at 2 kHz (p = 0.01, Mann-Whitney U test). Among the devices, the Osia system tended to tolerate the worst bone conduction thresholds, up to the level of 61 dB. In the SSD group, the functional gain of Osia at 4 kHz (37.5 ± 3.1 dB) was higher than that of the Baha and Bonebridge group (26.9 ± 3.0 dB) (p = 0.05, Mann-Whitney U test). CONCLUSION The Osia system yielded larger audiological gain than the Baha Attract and Bonebridge devices, especially at high frequencies, leading to substantially higher compliance. The Osia system tended to have the strongest tolerance to aggravated bone conduction thresholds among the available transcutaneous bone conduction hearing implants. Therefore, the Osia system could potentially be a good option for CHL/MHL patients with bone conduction thresholds of 50 dB HL or more, as well as patients with SSD.
Collapse
|
13
|
Multicentric study on surgical information and early safety and performance results with the Bonebridge BCI 602: an active transcutaneous bone conduction hearing implant. Eur Arch Otorhinolaryngol 2023; 280:1565-1579. [PMID: 36625869 PMCID: PMC9988757 DOI: 10.1007/s00405-022-07792-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 12/10/2022] [Indexed: 01/11/2023]
Abstract
AIM This European multicentric study aimed to prove safety and performance of the Bonebridge BCI 602 in children and adults suffering from either conductive hearing loss (CHL), mixed hearing loss (MHL), or single-sided sensorineural deafness (SSD). METHODS 33 patients (13 adults and 10 children with either CHL or MHL and 10 patients with SSD) in three study groups were included. Patients were their own controls (single-subject repeated measures), comparing the unaided or pre-operative to the 3-month post-operative outcomes. Performance was evaluated by sound field thresholds (SF), word recognition scores (WRS) and/or speech reception thresholds in quiet (SRT) and in noise (SNR). Safety was demonstrated with a device-specific surgical questionnaire, adverse event reporting and stable pure-tone measurements. RESULTS The Bonebridge BCI 602 significantly improved SF thresholds (+ 25.5 dB CHL/MHL/SSD), speech intelligibility in WRS (+ 68.0% CHL/MHL) and SRT in quiet (- 16.5 dB C/MHL) and in noise (- 3.51 dB SNR SSD). Air conduction (AC) and bone conduction (BC) thresholds remained stable over time. All adverse events were resolved, with none unanticipated. Mean audio processor wearing times in hours [h] per day for the CHL/MHL group were ~ 13 h for adults, ~ 11 h for paediatrics and ~ 6 h for the SSD group. The average surgical length was 57 min for the CHL/MHL group and 42 min for the SSD group. The versatility of the BCI 602 (reduced drilling depth and ability to bend the transition for optimal placement) allows for treatment of normal, pre-operated and malformed anatomies. All audiological endpoints were reached. CONCLUSIONS The Bonebridge BCI 602 significantly improved hearing thresholds and speech understanding. Since implant placement follows the patient's anatomy instead of the shape of the device and the duration of surgery is shorter than with its predecessor, implantation is easier with the BCI 602. Performance and safety were proven for adults and children as well as for the CHL/MHL and SSD indications 3 months post-operatively.
Collapse
|
14
|
Subtemporalis Muscle Middle Cranial Fossa Bone-Island Craniotomy Technique for Placement of an Active Transcutaneous Bone-Conduction Implant. Otol Neurotol 2023; 44:54-60. [PMID: 36509440 PMCID: PMC9762702 DOI: 10.1097/mao.0000000000003760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVE Placement of an active transcutaneous bone-conduction implant (BCI) requires drilling of a precise bone bed to accommodate the device and allow for fixation points to make appropriate contact with bone, which can be difficult even when lifts are used. We describe a subtemporalis muscle middle cranial fossa bone-island craniotomy technique that simplifies the procedure and obviates the need for lifts in securing the device. STUDY DESIGN Prospective case series. SETTING Tertiary academic medical center. PATIENTS Seventeen patients underwent surgery for placement of 18 transcutaneous BCIs, 14 for conductive or mixed hearing loss, and 4 for single-sided deafness. INTERVENTIONS Surgical placement of a transcutaneous BCI with a bone-island craniotomy technique. MAIN OUTCOME MEASURES Functional gain in air-conduction thresholds, aided air-bone gap, frequency of need for lifts, and minor and major complications. RESULTS For the conductive or mixed hearing loss cohort, with the transcutaneous BCI in place, there was a highly statistically significant mean functional gain of 35.4 dB hearing level (HL) (range, 16.7-50.25 dB HL; standard deviation, 12.4 dB HL) compared with the unaided condition (p < 0.0001; 95% confidence interval, 36.6-51.6 dB HL). Lifts were not needed in any case. There was one minor complication requiring a second procedure in a patient who had previously received radiation and no major complications. There was no device loss or failure. CONCLUSIONS A subtemporalis muscle middle cranial fossa bone-island craniotomy technique eliminates the need for lifts and is a safe and effective method for placement of a transcutaneous BCI.
Collapse
|
15
|
Initial Experience With Two Active Transcutaneous Bone-Anchored Hearing Implants. Otol Neurotol 2022; 43:1212-1215. [PMID: 36075090 DOI: 10.1097/mao.0000000000003681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To analyze our institutional experience with two active transcutaneous bone-anchored hearing aids. STUDY DESIGN Retrospective cohort study. SETTING Tertiary academic otology-neurotology practice. PATIENTS Patients with conductive or mixed hearing losses meeting criteria to receive active transcutaneous bone-anchored hearing aids. INTERVENTIONS Implantation with one of two active transcutaneous bone-anchored hearing aids. OUTCOME MEASURES Operative time, dural exposure and decompression, use of lifts, implant position, ease of use, qualitative patient satisfaction, complication rates. RESULTS Ten patients received Implant 1 and 11 patients received Implant 2. The most common underlying etiologies of hearing loss were chronic suppurative otitis media in 33.3%, atresia/microtia in 23.8%, and cholesteatoma in 23.8%. Average operative times were 99.3 minutes for Implant 1 and 80.9 minutes for Implant 2 ( p = 0.263). Implant 1 required lifts in 60%, dural exposure in 50%, and dural compression in 30%. Overall, placement was difficult in 47.6% of cases. There were no intraoperative complications. There were higher rates of issues with sound quality (27.3% versus 0.0%, p = 0.123) and poor cosmesis (36.4% versus 10.0%, p = 0.360) with Implant 2. Functional gain was not recorded, but all patients derived qualitative benefit from their implant. Three patients had local wound complications that self-resolved or were treated with antibiotics. One patient implanted at an outside institution required explant because of multiple infections. CONCLUSIONS There were no statistically significant differences in outcomes comparing Implants 1 and 2; however, Implant 2 had much higher rates of issues with audio quality and poor cosmesis. Placing Implant 1 often required special techniques.
Collapse
|
16
|
Long-term data of the new transcutaneous partially implantable bone conduction hearing system Osia®. Eur Arch Otorhinolaryngol 2022; 279:4279-4288. [PMID: 34792628 PMCID: PMC9363475 DOI: 10.1007/s00405-021-07167-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Accepted: 11/01/2021] [Indexed: 01/07/2023]
Abstract
PURPOSE The new active transcutaneous partially implantable osseointegrated system Cochlear™ Osia® System is indicated in case of conductive or mixed hearing loss (CHL/MHL) with a maximum average bone conduction hearing loss of 55 dB, or in single-sided deafness (SSD). The implant directly stimulates the bone via a piezoelectric transducer and is directed by an external sound processor. We conducted a monocentric retrospective longitudinal within-subject clinical study at our tertiary academic referral center. The aim was to investigate long-term data (2017-2021) on audiological outcomes and hearing-related quality of life for the Osia system. METHODS Between 2017 and 2020, 22 adults (18: CHL/MHL; 3: SSD) were implanted with the Osia100 implant; seven received bilateral implants. As of 10/2020, the sound processor was upgraded to Osia 2. RESULTS Mean Osia system use by 04/2021 was 30.9 ± 8.6 months (range 17-40 months). Unaided bone conduction thresholds were unchanged postoperatively. One patient had to be explanted because of prolonged wound infection. Aided hearing thresholds were significantly lower compared to the unaided thresholds preoperatively, along with a marked increase in speech recognition in quiet. Speech processor upgrade resulted in a stable benefit. Patients with CHL/MHL and SSD showed a similar improvement in self-rated hearing performance revealed by SSQ, APHAB, and HUI questionnaires. CONCLUSION The Osia system is a safe, effective and sustainable option for treatment of conductive and mixed hearing loss or single-sided deafness.
Collapse
|
17
|
Evaluation of the Bonebridge BCI 602 active bone conductive implant in adults: efficacy and stability of audiological, surgical, and functional outcomes. Eur Arch Otorhinolaryngol 2022; 279:3525-3534. [PMID: 35182185 PMCID: PMC9130189 DOI: 10.1007/s00405-022-07265-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 01/10/2022] [Indexed: 01/21/2023]
Abstract
PURPOSE (1) To assess the effectiveness and safety of a bone-conduction implant, the Bonebridge BCI 602, in adults with conductive or mixed hearing loss. (2) To investigate whether the Bonebridge BCI 602 is at least as effective as the Bonebridge BCI 601 in such patients. METHODS The study group included 42 adults who had either conductive or mixed hearing loss. All patients underwent Bonebridge BCI 602 implant surgery. Before and after implantation, pure-tone audiometry, speech recognition tests (in quiet and noise), and free-field audiometry were performed. Word recognition scores were evaluated using the Polish Monosyllabic Word Test. Speech reception thresholds in noise were assessed using the Polish Sentence Matrix Test. Subjective assessment of benefits was done using the APHAB (Abbreviated Profile of Hearing Aid Benefit) questionnaire. RESULTS The APHAB questionnaire showed that difficulties in hearing decreased after BCI 602 implantation. Both word recognition in quiet and speech reception threshold in noise were significantly better after BCI 602 implantation and remained stable for at least 12 months. A significant advantage of the device is a reduced time for surgery while maintaining safety. In this study, the mean time for BCI 602 implantation was 28.3 min ± 9.4. CONCLUSIONS The second-generation Bonebridge BCI 602 implant is an effective hearing rehabilitation device for patients with conductive or mixed hearing loss. Patient satisfaction and audiological results confirm its efficacy and safety. Its new shape and dimensions allow it to be used in patients previously excluded due to insufficient or difficult anatomical conditions. The new BCI 602 implant is as effective as its predecessor, the BCI 601.
Collapse
|
18
|
Clinical Performance Assessment of a New Active Osseointegrated Implant System in Mixed Hearing Loss: Results From a Prospective Clinical Investigation. Otol Neurotol 2021; 42:e905-e910. [PMID: 33710155 PMCID: PMC8279898 DOI: 10.1097/mao.0000000000003116] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
OBJECTIVE Evaluation of a new active osseointegrated bone-conduction hearing implant in moderate to severe mixed-hearing loss. STUDY DESIGN Prospective observational study of a series of cases. SETTING Tertial referral center. PATIENTS Twenty patients with moderate mixed-hearing loss were evaluated (10 Cochlear Osia group and 10 Baha 5 Power Connect -control group). INTERVENTION Rehabilitative. MAIN OUTCOME MEASURES Hearing performance in quiet and in noise and quality-of-life were evaluated. RESULTS Improvements in audibility, speech-understanding, speech-recognition, and quality-of-sound in noise and quiet were found for the Osia System compared with preoperative unaided hearing and performance was similar to that obtained with Baha 5 Power Connect. CONCLUSIONS The new active transcutaneous bone conduction system provided a tonal improvement in free-field at middle and high frequencies. The performance in speech recognition in quiet and in noise was similar to control group outcomes.
Collapse
|
19
|
Implantable Devices for Single-Sided Deafness and Conductive or Mixed Hearing Loss: A Health Technology Assessment. ONTARIO HEALTH TECHNOLOGY ASSESSMENT SERIES 2020; 20:1-165. [PMID: 32194878 PMCID: PMC7080453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
BACKGROUND Single-sided deafness refers to profound sensorineural hearing loss or non-functional hearing in one ear, with normal or near-normal hearing in the other ear. Its hallmark is the inability to localize sound and hear in noisy environments. Conductive hearing loss occurs when there is a mechanical problem with the conduction of sound vibrations. Mixed hearing loss is a combination of sensorineural and conductive hearing loss. Conductive and mixed hearing loss, which frequently affect both ears, create additional challenges in learning, employment, and quality of life. Cochlear implants and bone-conduction implants may offer objective and subjective benefits of hearing for people with these conditions who are deemed inappropriate candidates for standard hearing aids and do not meet the current indication (i.e., bilateral deafness) for publicly funded cochlear implants in Canada. METHODS We conducted a health technology assessment, which included an evaluation of clinical benefits and harms, cost-effectiveness, budget impact, and patient preferences and values related to implantable devices for single-sided deafness and conductive or mixed hearing loss. We performed a systematic literature search for systematic reviews and cost-effectiveness studies of cochlear implants and bone-conduction implants, compared to no interventions, for these conditions in adults and children. We conducted cost-utility analyses and budget impact analyses from the perspective of the Ontario Ministry of Health to examine the impact of publicly funding both types of hearing implants for the defined populations. We also interviewed 22 patients and parents of children about their experience with hearing loss and hearing implants. RESULTS We included 20 publications in the clinical evidence review. For adults and children with single-sided deafness, cochlear implantation when compared with no treatment improves speech perception in noise (% correct responses: 43% vs. 15%, P < .01; GRADE: Moderate), sound localization (localization error: 14° vs. 41°, P < .01; GRADE: Moderate), tinnitus (Visual Analog Scale, loudness: 3.5 vs. 8.5, P < .01; GRADE: Moderate), and hearing-specific quality of life (Speech Spatial and Qualities of Hearing Scale, speech: 5.8 vs. 2.6, P = .01; spatial: 5.7 vs. 2.3, P < .01; GRADE: Moderate); for children, speech and language development also improve (GRADE: Moderate). For those with single-sided deafness in whom cochlear implantation is contraindicated, bone-conduction implants when compared with no intervention provide clinically important functional gains in hearing thresholds (36-41 dB improvement in pure tone audiometry and 38-56 dB improvement in speech reception threshold, P < .05; GRADE: Moderate) and improve speech perception in noise (signal-to-noise ratio -2.0 vs. 0.6, P < .05 for active percutaneous devices; signal-to-noise ratio improved by 1.3-2.5 dB, P < .05 for active transcutaneous devices; GRADE: Moderate) and hearing-specific quality of life (Abbreviated Profile for Hearing Aid Benefit, ease of communication: 12%-53% vs. 24%-59%; background noise: 18%-48% vs. 33%-79%; listening in reverberant condition: 26%-55% vs. 41%-65%, P < .05 [active percutaneous devices]; ease of communication: 7% vs. 20%; background noise: 46% vs. 69%; listening in reverberant condition: 27% vs. 43%; P < .05 [active transcutaneous devices]; Children's Home Inventory for Listening Difficulties score 7.3 vs. 3.4; P < .05 [passive transcutaneous devices]; GRADE: Moderate). For those with conductive or mixed hearing loss, bone-conduction implants when compared with no intervention improve hearing thresholds (improved 19-45 dB [active percutaneous devices], improved 24-37 dB [active transcutaneous devices], improved 31 dB [passive transcutaneous devices], and improved 21-49 dB [active transcutaneous middle-ear implants]; GRADE: Moderate), speech perception (% correct: 77%-93% vs. < 25%; P < .05 [active transcutaneous devices], % speech recognition: 55%-98% vs. 0-72%; P < .05 [active transcutaneous middle-ear implants]; GRADE: Moderate), and hearing-specific quality of life and subjective benefits of hearing (GRADE: Moderate).In the cost-utility analyses, cochlear implants for adults and children with single-sided deafness provided greater health gains for an incremental cost, compared with no intervention. On average, the incremental cost-effectiveness ratio (ICER) was between $17,783 and $18,148 per quality-adjusted life-year (QALY). At a willingness-to-pay of $100,000 per QALY, 70% of the simulations were considered cost-effective. For the same population, bone-conduction implants were not likely to be cost-effective compared with no intervention (ICER: $402,899-$408,350/QALY). Only 38% of simulations were considered cost-effective at a willingness-to-pay of $100,000 per QALY. For adults and children with conductive or mixed hearing loss, bone-conduction implants may be cost-effective compared with no intervention (ICER: $74,155-$87,580/QALY). However, there was considerable uncertainty in the results. At a willingness-to-pay of $100,000 per QALY, only 50% to 55% of simulations were cost-effective. In sensitivity analyses, results were most sensitive to changes in health-related utilities (measured using generic quality-of-life tools), highlighting the limitations of currently published data (i.e., small sample sizes and short follow-up).For people with single-sided deafness, publicly funding cochlear implants in Ontario would result in an estimated additional cost of $2.8 million to $3.6 million in total over the next 5 years, and an additional $0.8 million would be required for bone-conduction implants for this population. For people with conductive or mixed hearing loss, publicly funding bone-conduction implants would cost an estimated additional $3.1 million to $3.3 million in total over the next 5 years.In interviews, people with single-sided deafness and conductive or mixed hearing loss reported that standard hearing aids did not meet their expectations; therefore, they chose to undergo surgery for an implantable device. Most participants with experience of a cochlear implant or bone-conduction implant spoke positively about being able to hear better and enjoy a better quality of life. People with a cochlear implant reported additional benefits: binaural hearing, better sound localization, and better hearing in noisy areas. Cost and access were barriers to receiving an implantable device. CONCLUSIONS Based on evidence of moderate quality, cochlear implantation and bone-conduction implants improve functional and patient-important outcomes in adults and children with single-sided deafness and conductive or mixed hearing loss. Qualitative results of interviews with patients are consistent with the findings of the systematic reviews we examined.Among people with single-sided deafness, cochlear implants may be cost-effective compared with no intervention, but bone-conduction implants are unlikely to be. Among people with conductive or mixed hearing loss, bone-conduction implants may be cost-effective compared with no intervention. Results and uncertainty are mainly driven by changes in health utilities associated with having a hearing implant. Hence, further research on utility values in this population is warranted with larger sample sizes and longer follow-up.The 5-year cost of publicly funding both types of hearing implant for single-sided deafness and conductive or mixed hearing loss in Ontario is estimated to be $6.7 million to $7.8 million.
Collapse
|
20
|
Stapes Surgery for Otosclerosis in Patients Presenting with Mixed Hearing Loss. Audiol Neurootol 2018; 23:82-88. [PMID: 30130744 DOI: 10.1159/000489813] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Accepted: 05/03/2018] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVES To evaluate the efficacy of stapes surgery in patients presenting with a preoperative mixed hearing loss (bone conduction thresholds ≥40 dB; 40 < air conduction thresholds (AC) < 85 dB). PATIENTS AND METHODS A total of 30 patients (32 ears) with mixed hearing loss who underwent primary stapedotomy were evaluated. Audiometric parameters were assessed before and after surgery. Contralateral thresholds were also reported. The need for a hearing aid (HA) after surgery and its impact on quality of life were also measured. RESULTS AC and word recognition at 40, 55 and 70 dB were significantly improved after stapes surgery. Only 16.6% of the patients needed an HA after surgery and reported being satisfied with the aid. CONCLUSION Stapes surgery improved auditory function in patients with mixed hearing loss, allowing most patients to delay the need for an HA without worsening their quality of life.
Collapse
|
21
|
Abstract
After more than 25 years of clinical experience, the BAHA (bone-anchored hearing aid) system is a well-established treatment for hearing-impaired patients with conductive or mixed hearing loss. Owing to its success, the use of the BAHA system has spread and the indications for application have gradually become broader. New indications, as well as clinical applications, were discussed during scientific roundtable meetings in 2004 by experts in the field, and the outcomes of these discussions are presented in the form of statements. The issues that were discussed concerned BAHA surgery, the fitting range of the BAHA system, the BAHA system compared to conventional devices, bilateral application, the BAHA system in children, the BAHA system in patients with single-sided deafness, and, finally, the BAHA system in patients with unilateral conductive hearing loss.
Collapse
|
22
|
Abstract
CONCLUSION Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. OBJECTIVES To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. METHOD To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. RESULTS Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.
Collapse
|
23
|
Transcutaneous bone-conduction hearing device: audiological and surgical aspects in a first series of patients with mixed hearing loss. Acta Otolaryngol 2013; 133:1058-64. [PMID: 23768011 DOI: 10.3109/00016489.2013.799293] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
CONCLUSIONS The Bonebridge(®) (BB) transcutaneous bone conductive implant (BCI) may overcome some of the issues related to a percutaneous BCI, such as management of the external screw, delayed activation or possible skin complications. Moreover, it has been shown to enable a functional outcome similar to percutaneous BCI in both conductive and mixed types of hearing loss. OBJECTIVES To obtain clinical data from a preliminary series of patients implanted with a new transcutaneous BCI. METHODS Four subjects affected by conductive/mixed hearing loss underwent implantation of the BB by two approaches: the transmastoid, presigmoid approach and the retrosigmoid approach. Soundfield thresholds were assessed with warble tones in a soundproof audiometric booth, and word recognition scores (WRSs) as speech reception thresholds (SRTs) were used to compare the unaided versus the post-implantation condition. RESULTS The surgical procedure was completed in all cases, with only minor intraoperative divergence from the CT-based planning and no postoperative complications. The average improvement of the SRT in quiet with the BB in comparison to the unaided condition was 36.25 dB. All the implanted subjects reached SRT values below 65 dB, indicating a better understanding in quiet, with 100% word recognition.
Collapse
|
24
|
Middle ear implant in conductive and mixed congenital hearing loss in children. Int J Pediatr Otorhinolaryngol 2012; 76:1775-8. [PMID: 22985678 DOI: 10.1016/j.ijporl.2012.08.022] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2012] [Revised: 08/20/2012] [Accepted: 08/22/2012] [Indexed: 11/20/2022]
Abstract
PURPOSE Active middle ear implant can be used in children and adolescents with congenital hearing loss. The authors report their experience with the semi implantable Medel Vibrant Soundbridge(®) (VSB) in the audiologic rehabilitation of such patients. METHODS In this retrospective study, audiological and surgical data of 10 children (10.5±4 years) implanted with 12 VSB in 2 tertiary cares ENT Departments were analysed. RESULTS Two children with bilateral external auditory canal (EAC) atresia and mixed hearing loss (mean air conduction (AC) thresholds=65dB HL) were bilaterally implanted. Eight children presented with microtia associated with EAC atresia bilaterally (n=3) and unilaterally (n=5). All of them had a conductive hearing loss in the implanted ear (mean (AC) thresholds were 58.75dB HL preoperatively). The Floating Mass Transducer was crimped on the long process of the incus (n=8) or on the suprastructure of the stapes (n=4). There were no intra- or postoperative surgical complications. All the children wore their implants after 5 weeks. Postoperative mean bone conduction (BC) thresholds were unchanged. The mean aided thresholds with VSB (four frequencies warble tones at 0.5, 1, 2 and 4 kHz) were 28dB HL (± 10). Word discrimination threshold in quiet conditions in free field with the VSB unilaterally activated was 50% at 38dB SPL (± 9). CONCLUSION The results indicate that satisfaction of the children and their parents is very encouraging but surgeons should be cautious with this new approach in relation to the pinna reconstruction and to possible risks to inner ear and facial nerve.
Collapse
|
25
|
Abstract
Usage of the Vibrant Soundbridge (VSB) with round window (RW)-Coupler placement at the RW has been shown to successfully treat mixed hearing loss. Coupling between the VSB's floating mass transducer (FMT) and the RW membrane is difficult in the case of sclerosis in the RW and drilling down the bony lip until the RW membrane can be seen completely can possibly induce a perilymphatic fistula. A 68-year-old woman who had bilateral mixed hearing loss with sclerosis in the RW due to tympanosclerosis underwent a RW-Vibroplasty with a RW-Coupler. Speech discrimination scores in quiet and noise and functional gain with the VSB with RW-Coupler were better than those using a conventional hearing aid. The results of the present case have shown the feasibility of implanting a VSB with RW-Coupler in patients with mixed hearing loss due to tympanosclerosis.
Collapse
|
26
|
[Diagnosis and treatment of traumatic ossicular chain disruption and dislocation]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY, HEAD, AND NECK SURGERY 2012; 26:300-305. [PMID: 22737869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
OBJECTIVE To investigate the diagnose therapy and the postoperative curative effect of traumatic ossicular chain disruption and dislocation. METHOD Eight cases (8 ears) with traumatic ossicular chain disruption. Six cases of unilateral conductivity deafness, 2 of mixed deafness still with conductive primarily. Eight ears all were performed tympanic exploration and ossicular replacement prosthesis, 1 ear with TORP (total ossicular replacement prosthesis). 4 ears with PORP (partial ossicular replacement prosthesis), 2 with ossicular chain reset, 1 with artificial incus reconstruction. The treatment effect was compared by the preoperative and postoperative ABG (air bone gap). RESULT Preoperative average ABG was 42. 9 dB, the average ABG 3 weeks after operation was 22.3 dB, which reduced 20.6 dB compared to the preoperative, having a statistically significant difference (t = 22.10, P < 0.01). The average ABG was 18.6 dB 6-8 months after operation, which reduced 24.3 dB compared to the preoperative, having a statistically significant difference (t = 12.813, P < 0.01). CONCLUSION The conductivity hearing loss after traumatic ossicular chain disruption or dislocation is preferred operation treatment, and replacement should use different ways according to the operation in case, and the hearing improvement was obvious.
Collapse
|
27
|
Abstract
INTRODUCTION This review covers the surgery for the bone-anchored hearing aid (Baha(®)). PREOPERATIVE WORKUP: A review of the indications and preoperative diagnostics shows that best results are generally obtained in patients with conductive or mixed hearing loss rehabilitation when surgery is not applicable or has failed and in patients that suffer from single-sided deafness. An audiogram must confirm that the bone conduction hearing is within the inclusion criteria. A computed tomography scan is performed in cases of malformation to assure sufficient bone thickness at the site of screw implantation. PROCEDURE The steps of the Baha implantation are described step by step including the setting and anesthesia, skin work with regard to different techniques, correct resection of subcutaneous tissue, preparation of the implant site, drilling and placement of the fixture and wound closure. POSTOPERATIVE CARE After wound healing (6-8 weeks), the bone conduction aid is fitted on the abutment. Regular cleaning of the fixture is important to avoid irritations and infections. CONCLUSION If performed carefully, the surgery for the Baha has a favorable outcome, regardless of the technique used.
Collapse
|
28
|
Abstract
In the past 30 years, a large amount of clinical and audiological research on bone conduction hearing devices has been performed. In this review, we give a brief history of the developments in indications, surgical techniques and sound processors with respect to implantable bone conduction devices like the bone-anchored hearing aid or Baha. Starting with the use of Baha in patients with bilateral conductive or mixed hearing loss (HL), the indications for such devices have been extended to patients with unilateral HL, children and moderate mentally retarded patients. Bilateral fitting has been shown to be beneficial in restoring binaural hearing in patients with bilateral acquired or congenital conductive HL. In addition, the surgical techniques used to implant the titanium fixture for Baha application have been modified and further developed to reach two main goals: (a) optimal osseointegration, and (b) preparation of the implant site to minimize the occurrence of soft tissue reactions. Currently, the most used techniques are the pedicled skin flap, dermatome and linear incision techniques. Several generations of the Baha(®) sound processor have been developed by Cochlear(TM) to provide sufficient amplification in different hearing situations. Improvements in sound quality, aesthetics and handling have been major points of interest. The Baha sound processors most often used today are the Baha(®) Divino, the Baha(®) Intenso and the Baha(®) Cordelle. Recently, the more flexible Baha(®) BP100 sound processor was launched.
Collapse
|
29
|
Fully implantable Otologics MET Carina(™) device for the treatment of sensorineural and mixed hearing loss: Audio-otological results. Acta Otolaryngol 2010; 130:1147-53. [PMID: 20380547 DOI: 10.3109/00016481003671244] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
CONCLUSION Our results attest that the Otologics MET Carina(™) is a viable treatment for moderate to severe sensorineural hearing loss (SNHL) and for cases of mixed hearing loss, and that in selected cases it could represent an alternative to conventional hearing aids. OBJECTIVES To describe our experience with the fully implantable Carina(™) in eight adult patients, seven with moderate to severe SNHL and one with mixed hearing loss. METHODS Eight implanted adult patients were submitted to a comprehensive audiological evaluation. RESULTS We did not record any surgical relevant complication in any of the patients, nor any significant postoperative variation in hearing thresholds, for air conduction or bone conduction, indicating the absence of surgical damage to the cochlea. All the patients demonstrated improvements in speech perception abilities with the device functioning and reported subjective benefits. With regard to the postoperative adverse effects, we had problems with feedback noise, which resolved with minor fitting adjustments in seven cases, while it required a second surgery to change the microphone position in the other patient. In one case a minimal extrusion of the microphone cable occurred requiring a revision surgery, a device failure occurred in one case, requiring substitution, and one patient decided on explantation of the device owing to psychological problems.
Collapse
|
30
|
Totally implantable active middle ear implants: ten years' experience at the University of Tübingen. Adv Otorhinolaryngol 2010; 69:72-84. [PMID: 20610916 DOI: 10.1159/000318524] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Active middle ear implants do not produce acoustic sounds but, rather, micromechanical vibrations. The stimulating signal does not leave the transducer as sound, but as a mechanical vibration, directly coupled to the auditory system and bypassing the normal route via air. In this paper, we review our experience with the TICA and the Carina middle ear implants. Both are totally implantable and are coupled to the ossicular chain or to perilymph. The design requirements for electronic hearing implants for patients with conductive hearing loss differ from those for sensorineural hearing loss. Conductive hearing loss requires an implant that replaces impedance transformation and acts as an impedance transforming implant (ITI). In many respects, there are fewer demands on an ITI than on an electronic hearing aid for patients with sensorineural hearing loss.
Collapse
|
31
|
The vibrant soundbridge for conductive and mixed hearing losses: European multicenter study results. Adv Otorhinolaryngol 2010; 69:38-50. [PMID: 20610913 DOI: 10.1159/000318521] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
BACKGROUND/AIMS The Vibrant Soundbridge (VSB) is an active middle ear implant, 'direct-drive' hearing system for the treatment of hearing loss. Recently, the VSB has been applied to conductive and mixed hearing losses. The aim of this study is to evaluate aided benefit, speech recognition in quiet and noise, subjective benefits, changes in residual hearing, and medical and surgical complications in adults with conductive or mixed hearing losses implanted with the VSB using Round Window (RW) Vibroplasty. METHODS Twelve German-speaking adults participated in a single-subject, repeated measures study design comparing their performance using the VSB with their own unaided preoperative performance. Hearing performance and changes in residual hearing were assessed using routine audiometric measures, sound field thresholds, and word and sentence recognition in quiet and in noise. Subjective benefits, including subjective hearing performance, device satisfaction, and quality of life were evaluated using the Abbreviated Profile of Hearing Aid Benefit, the Hearing Device Satisfaction Scale, and the Glasgow Benefit Inventory, respectively. RESULTS Aided hearing thresholds, word recognition at conversational levels, and sentence recognition in quiet and noise were significantly improved without significant changes in residual cochlear hearing and without major medical and surgical complications. One subject required repositioning surgery to improve transducer coupling with the RW membrane. Subjective benefit and device satisfaction were good, as were overall and general quality of life. CONCLUSION The VSB, implanted using RW vibroplasty, is a safe and effective treatment for adults with conductive and mixed hearing losses who may have few, if any, other options.
Collapse
|
32
|
Bilateral atticoantral chronic suppurative otitis media presenting as bilateral cutaneous mastoid fistulas. EAR, NOSE & THROAT JOURNAL 2009; 88:E1-E3. [PMID: 19826984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023] Open
Abstract
Postauricular cutaneous mastoid fistula secondary to chronic suppurative otitis media (CSOM) is an unusual complication. Bilateral manifestation along with primary acquired cholesteatoma and atelectasis of the pars tensa as an end-stage complication in the natural course of atticoantral CSOM is rare. This kind of complication has a very morbid effect on the ear, and it poses a therapeutic challenge in terms of eradicating disease and restoring function. In this article, we describe the unusual course of an atticoantral CSOM that (1) began as a primary acquired cholesteatoma simultaneously in both ears, (2) proceeded to automastoidectomy and a severe mixed hearing loss bilaterally, and (3) ended with the development of bilateral cutaneous mastoid fistulas that served to arrest the further progression of the disease process on its own. This case serves as a good demonstration of how a ventilating mastoid fistula can change the natural course of atticoantral CSOM and abort the occurrence of deadly complications.
Collapse
MESH Headings
- Cholesteatoma, Middle Ear/diagnosis
- Cholesteatoma, Middle Ear/surgery
- Cutaneous Fistula/diagnosis
- Cutaneous Fistula/surgery
- Ear Diseases/diagnosis
- Ear Diseases/surgery
- Ear, Middle/pathology
- Ear, Middle/surgery
- Fistula/diagnosis
- Fistula/surgery
- Hearing Loss, Bilateral/etiology
- Hearing Loss, Bilateral/surgery
- Hearing Loss, Mixed Conductive-Sensorineural/etiology
- Hearing Loss, Mixed Conductive-Sensorineural/surgery
- Humans
- Male
- Mastoid/pathology
- Mastoid/surgery
- Mastoiditis/diagnosis
- Mastoiditis/surgery
- Middle Aged
- Otitis Media, Suppurative/diagnosis
- Otitis Media, Suppurative/surgery
- Otoscopy
- Proteus Infections/diagnosis
- Proteus Infections/surgery
Collapse
|
33
|
Abstract
Objectives: We evaluated 5 patients who were changed over from a Baha Cordelle to a cochlear implant (CI). Moreover, the level of phoneme score was determined at which a Baha Cordelle user was better helped with a CI. Methods: We offer descriptive case reports and a retrospective evaluation of speech recognition in Baha Cordelle users and CI users. Results: In the CI users with noncompromised cochleas, the 10th percentile of the aided phoneme score in quiet at 65 dB sound pressure level (PS65) was 42%. We consider this PS65 as the cutoff level for switching from a Baha Cordelle to a CI. When patients with mixed hearing loss were using the Baha Cordelle, the PS65 of 42% was obtained at a mean sensorineural hearing loss component of about 70 dB hearing level (HL). This 70–dB HL component was used to consider Baha Cordelle users for cochlear implantation. The results of the 5 patients support these transition criteria. Conclusions: A CI is a valuable option in patients with mixed hearing loss when the sensorineural hearing loss component exceeds 70 dB HL or when the PS65 with a Baha Cordelle is less than about 40%. In such patients, the implantation procedure should be individualized on the basis of the clinical findings in the middle ear and mastoid cavity.
Collapse
|
34
|
Abstract
Early clinical findings are reported for subjects implanted with the Vibrant Med-El Soundbridge (VSB) device. The present criteria for the VSB, limiting its application to patients with normal middle ear function, have been extended to include patients with ossicular chain defects. Seven patients with severe mixed hearing loss were implanted with the transducer placed onto the round window. All had undergone previous surgery: six had multiple ossiculoplasties, and one had the VSB crimped on the incus with unsuccessful results. Round window implantation bypasses the normal conductive path and provides amplified input to the cochlea. Post-operative aided thresholds of 30 dB HL were achieved for most subjects, as compared with unaided thresholds ranging from 60-80 dB HL. Aided speech reception thresholds at 50% intelligibility were 50 dB HL, with most subjects reaching 100% intelligibility at conversational levels, while unaided thresholds averaged 80 dB HL, with only one subject reaching 100% intelligibility. These results suggest that round window implantation may offer a viable treatment option for individuals with severe mixed hearing losses who have undergone unsuccessful ossiculoplasties.
Collapse
|
35
|
Vibrant Soundbridge for hearing restoration after chronic ear surgery. REVUE DE LARYNGOLOGIE - OTOLOGIE - RHINOLOGIE 2009; 130:83-88. [PMID: 19813469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
INTRODUCTION Middle ear surgery is primarily concerned with resolving the discharging pathology, in the case of chronic otitis media (COM), or with complete eradication, in case of cholesteatoma. Either of these procedures may require repeated surgeries, often resulting in severe mixed hearing impairment. A middle ear implant may be indicated in these cases instead of a hearing aid because the anatomical conditions in such cases often impede an adequate acoustic coupling. The objective of this study was to evaluate MED-EL Vibrant Soundbridge (VSB) implantation in patients with severe conductive and mixed hearing loss occurring after middle ear surgery for cholesteatoma or chronic otitis media (COM). MATERIALS AND METHODS Over a 2-years period, the VSB system was implanted in 40 patients between 35 and 81 year old (mean: 59.5). Surgery was performed with comparable technique in 3 regional hospitals in Italy: Rovereto (n=16), Meran (n=12) and Tortona (n=12). The 40 candidates for implantation had a history of 1-5 previous surgeries. Of those, 20 patients suffered from COM and 20 from, cholesteatomas. The floating mass transducer (FMT) of the VSB was placed and stabilized on the round window niche in 32 cases; alternative positioning was necessary in 8 cases. Bone conduction (BC) was tested 1 day post-operatively. At 1 month post-surgery and between 6-9 months, open-field warble tones threshold in VSB-off and VSB-on conditions and open-field speech audiometry for words in quiet were conducted. RESULTS Results of BC audiometry one day post-operatively showed no significant changes in hearing. Unaided mean pure tone average (PTA4) was 82.38 dB SPL with a mean speech recognition threshold (SRT) of 94.28 dB SPL. Results obtained after a minimum of three months post-operatively were evaluated in terms of aided thresholds and functional gain. At VSB activation, the mean PTA4 was 50.63 dB SPL with a mean SRT of 61.68 dB. After 6-9 months, the group had a mean PTA4 of 47.89 dB SPL and a mean SRT of 53.33 dB SPL. CONCLUSIONS Implantation of the VSB with its direct driver of the inner ear fluids appears promising for auditory rehabilitation of severe mixed hearing loss associated with sequelae of cholesteatoma surgery. Patients' results improved over time, allowing us to assume a positive effect of consolidation of the coupling related to fibrosis. Results reported here refer to 6-9 months of observation and do not provide evidence of long term stability.
Collapse
|
36
|
Vibrant Soundbridge middle ear implant in mixed hearing loss. Indications, techniques, results. REVUE DE LARYNGOLOGIE - OTOLOGIE - RHINOLOGIE 2009; 130:75-81. [PMID: 19813468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
OBJECTIVES The aim of this article is to illustrate the aetiologies of mixed hearing loss that can benefit from a Vibrant Soundbridge (VSB) middle ear implant, the techniques performed and the first results. MATERIALS AND METHOD The authors report their experience of 13 implantations in mixed hearing loss due to otosclerosis, sequelae of chronic otitis media and congenital aural atresia. The VSB implant was implanted alone or in association with another middle ear surgical procedure, on the ossicular chain or on the round window membrane. RESULTS The average auditory gain for all patients is 32 dB for pure tone thresholds, and 25 dB for speech recognition. It results from the addition of a gain on the conductive hearing loss by direct stimulation of the inner ear, to a gain on the sensorineural hearing loss by amplification. CONCLUSION Middle ear implants are the only hearing aids affording a gain in both the conductive and sensorineural components of mixed hearing losses.
Collapse
|
37
|
Histologic and morphologic evaluation of explanted bone anchors from bone-anchored hearing aids. Eur Arch Otorhinolaryngol 2008; 266:745-52. [PMID: 18853170 DOI: 10.1007/s00405-008-0830-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2008] [Accepted: 09/26/2008] [Indexed: 11/25/2022]
Abstract
Bone-anchored hearing aids are a standard option in rehabilitation of patients with conductive or mixed hearing loss, and also CROS fitting. However, the skin-penetrating bone anchor repeatedly gives reason for discussion about the risk of infection of surrounding tissues as a major cause of malfunction. In the present study, explanted bone anchors with surrounding bone and soft tissue were examined and compared with the morphology of lost implants. The anchors originated from five patients. Two needed explantation due to deafness with the need of cochlea implantation. A third patient underwent explantation due to meningeal irritation by the bone anchor. Another patient lost the implant due to mechanical stress shortly after implantation. The last implant was lost in a child without apparent reason. All implants were clinically free of infection and had been stable for a median implantation period of 12 months. During the explantation procedure, the fixtures were recovered together with the attached soft tissue and bone. The specimens were examined by light microscopy or scanning electron microscopy (SEM). Sectioning for light microscopy was performed with a diamond-coated saw microtome. Histopathologic examination of the surrounding skin and subcutaneous soft tissue showed slight inflammation in one case only. The bone was regularly vital, presenting no signs of inflammation. The threads of the fixtures were filled with bone, with particularly strong attachment to the flank of traction. The SEM investigation exposed the ultrastructural interaction of bone with the implant surface. Filiform- and podocyte-like processes of osteocytes attach to the implant; lost implants did not reflect these features. Implant integration involves both osseointegration as well as soft tissue integration. Titanium oxide as the active implant surface promotes this integration even in unstable implants. The morphologic analysis exposed structural areas of the implant with weak bone-to-metal contact. Optimized implant design with modified surface and threads may additionally improve osseointegration of hearing aid bone anchors.
Collapse
|
38
|
Comparison of pre and post-operative hearing results in canal wall down mastoidectomy with type III tympanoplasty. JNMA J Nepal Med Assoc 2008; 47:224-227. [PMID: 19079400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023] Open
Abstract
This study was done to compare the pre and post-operative hearing results in patients undergoing canal wall down mastoidectomy with classical type III tympanoplasty using temporalis fascia alone. Patients of >or=5 years age with the diagnosis of Chronic otitis media (squamous) with conductive or mixed hearing loss, needing canal wall down mastoidectomy and with intact and mobile stapes suprastructure at surgery who underwent classical type III tympanoplasty were included in the study. The pre and post-operative PTA was performed and evaluated. The post-operative hearing was assessed in terms of average ABG and size of ABG closure. Mean pre and post-operative air bone gap in classical type III tympanoplasty were 37.8 dB and 29.8 dB respectively and these differences were statistically significant. The postoperative PTA-ABG ranged from 15-61.2 dB. Hearing results after type III tympanoplasty varied widely showing statistically significant improvement in mean post-operative PTA-ABG but there was a great variation.
Collapse
|
39
|
A new implantable middle ear hearing device for mixed hearing loss: A feasibility study in human temporal bones. Otol Neurotol 2008; 27:1104-9. [PMID: 17031322 DOI: 10.1097/01.mao.0000244352.49824.e6] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
HYPOTHESIS To assess the feasibility of a new, active middle ear device in temporal bones (TB). BACKGROUND This device is designed for patients with mixed hearing loss subsequent to chronic middle ear infection, surgery, or trauma. This Bell-Vibroplasty is built from a VIBRANT MED-EL Vibrant Soundbridge and a Kurz Bell titanium partial ossicular replacement prosthesis. METHODS In three fresh TBs, healthy and reconstructed middle ears were analyzed by means of laser Doppler interferometry. The sound transmission properties of a partial ossicular replacement prosthesis and a passive and an active Bell-Vibroplasty were compared with healthy middle ear function. RESULTS The measurements provided reliable results with small standard deviations and good signal-to-noise ratios. The performance levels of the partial ossicular replacement prosthesis and of the passive Bell-Vibroplasty were comparable with that of healthy middle ear function. The activated Bell-Vibroplasty provided linear function and a flat frequency response within the measured frequency range (500 Hz-8 kHz), with peak deviations of less than 10 dB. The maximum output of the Bell-Vibroplasty was equivalent to 125-dB sound pressure level. CONCLUSION Bell-Vibroplasty is feasible in TBs. Bell-Vibroplasty performance in TBs is sufficient to allow for a clinical trial as a next step.
Collapse
|
40
|
Satisfactory surgical option for congenital microtia with defects of external auditory meatus (EAM) and middle ear. Acta Otolaryngol 2007; 127:705-10. [PMID: 17573566 DOI: 10.1080/00016480601053065] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
CONCLUSIONS Improved appearance and hearing and increased efficiency are achievable for congenital microbia with defects of external auditory meatus (EAM) and middle ear. First the site of the external auditory meatus (EAM) orifice must be located according to the results of the temporal CT scan, then the auricle can be reconstructed employing the three-stage method. At the third stage, the EAM and middle ear can be reconstructed at the same time. OBJECTIVE To select the best approach for reconstruction of congenital microtia with defects of the EAM and middle ear. PATIENTS AND METHODS This study analyzed 498 cases (528 ears) of auricle reconstruction by the three-stage method and 77 cases (91 ears operation/120 ears) of EAM and middle ear reconstruction. RESULTS For auricular reconstructions, the effects of reconstructed auricles were classified into four grades according to their structure verisimilitude and the bilateral symmetry. The majority of patients/families were satisfied. For 52 ears with normal movement of stapes, reconstructions of EAM and middle ear improved hearing by 15-50 dB, but long-term improvement was not ideal. In bilateral patients, 20 of 24 ears with reconstructed EAMs exhibited relapse of stenosis or atresia. For patients whose EAMs were reconstructed first, scar developed around the orifice and affected the skin flap and later auricle reconstruction, while reconstructing the auricle first sometimes resulted in the location of the EAM orifice deviating from an ideal position.
Collapse
|
41
|
Abstract
With our growing experience with the Vibrant Soundbridge (VSB) middle ear implant, the question emerged of its indication in mixed hearing loss due to advanced otosclerosis. We describe the VSB implantation technique in primary otosclerosis performed together with a stapedotomy piston procedure. Hearing results under headphone and free-field conditions show that the stapedotomy piston procedure closes the air-bone gap as expected and that the VSB provides comparable gain to that usually recorded for pure sensorineural hearing loss. The gains of the two procedures add up. These results open the field of mixed hearing loss to the VSB middle ear implant.
Collapse
|
42
|
Abstract
Middle ear implantation is an efficient procedure to restore moderate to severe sensorineural hearing loss (HL) in selected patients. Implantation of such devices requires ossicular chain integrity. Patients suffering from otosclerosis with mixed HL should be eligible for this treatment after stapes surgery with air-bone gap closure. To address this issue, we report four cases of middle ear implantation after or during stapes surgery. Results and complications obtained with Vibrant SoundBridge, MedEl and Middle Ear Transducer, Otologics are reported. Audiologic results were similar to those obtained in cases of sensorineural HL. One case of postoperative labyrinthitis was observed.
Collapse
|
43
|
How to prevent a stapes gusher. Adv Otorhinolaryngol 2007; 65:278-284. [PMID: 17245059 DOI: 10.1159/000098843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
A stapes gusher is the result of a congenital inner ear anomaly showing at tone audiometry a conductive or mixed hearing loss. The conductive part of the hearing loss could lead to the thought to explore the middle ear. The congenital origin should lead to a high resolution. CT-scanning to evaluate a widening of the internal acoustic canal. Repeated audiometry could show especially a large conductive impairment in the lowest frequencies with a closure of the airbone gap at 2 khz and a high sensorineural high frequency loss at 4 and 8 khz. Contralateral stapedial reflexes may be present. Since the x-recessive mixed deafness syndrome (DFN3) frequently involves males with an early childhood hearing impairment, clinical suspicion should be high. When stapes surgery is considered a precise medical history is essential regarding on the start of the hearing impairment. A continuous suspicion will guide to the audiological, radiological and molecular genetic clues to trace the correct diagnosis before embarking on stapes surgery.
Collapse
MESH Headings
- Adolescent
- Adult
- Audiometry, Pure-Tone
- Child
- Chromosomes, Human, X
- Cochlear Diseases/genetics
- Cochlear Diseases/prevention & control
- Ear Canal
- Female
- Fistula/genetics
- Fistula/prevention & control
- Genes, Recessive
- Genetic Carrier Screening
- Genetic Predisposition to Disease/genetics
- Genetic Testing
- Hearing Loss, Conductive/genetics
- Hearing Loss, Conductive/surgery
- Hearing Loss, Mixed Conductive-Sensorineural/genetics
- Hearing Loss, Mixed Conductive-Sensorineural/surgery
- Humans
- Intraoperative Complications/prevention & control
- Male
- Medical History Taking
- POU Domain Factors/genetics
- Pedigree
- Perilymph
- Semicircular Canals/abnormalities
- Sex Chromosome Aberrations
- Stapes Surgery/adverse effects
- Syndrome
- Tomography, X-Ray Computed
- Vestibule, Labyrinth/abnormalities
Collapse
|
44
|
Abstract
Osteogenesis imperfecta (OI) is a heterogenous connective tissue disorder. The classical triad of symptoms involves a conductive and/or sensorineural hearing impairment together with a tendency to spontaneous bone fractures and blue sclerae. Between 1993-2004, primary stapes surgery was performed on 14 ears of 11 OI patients who presented with conductive and/or mixed hearing loss. Pathological findings included atrophy and/or fractures of the stapedial crura in combination with thickening and fixation of the stapes footplate and hypervascularity of the promontory mucosa. All the patients with stapes surgery had significant hearing gain and bone conduction thresholds did not differ significantly in any of the cases; the mean postoperative air-bone gap at the main speech frequency range was within 10 dB in 13/14 (93%) and within 20 dB in 14/14 (100%). Hearing results following stapes surgery in patients with otosclerosis during the same time interval (n = 132) did not differ significantly. These data indicate that stapes surgery in OI can be performed safely with comparable functional predictability as in otosclerosis.
Collapse
|
45
|
[Expansion of an ceruminous adenoma into the middle ear]. Laryngorhinootologie 2006; 85:444-7. [PMID: 16770841 DOI: 10.1055/s-2005-870514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
A 37-year-old female presented for surgery with central perforation of the eardrum with granulation. Mastoidectomy had been performed 18 years ago following chronic mastoiditis. As the clinical picture now suggested a suspected cholesteatoma, radiological imaging was performed. The CT scan revealed specification of the mastoid and the tympanic cavity. In addition, MRI scan showed signal enhancement in the same areas. However, the suspected cholesteatoma could not be confirmed intraoperatively. Pathohistology revealed a ceruminal gland adenoma. They are a rare phenomenon and should be distinguished from middle ear adenomas, pleomorph ceruminal gland adenomas, ceruminal gland adenocarcinomas and cylindromas of the ceruminal glands. Owing to a high recurrence rate, complete surgical removal is necessary. Despite its rare occurrence, a ceruminal gland adenoma must be taken into consideration in the differential diagnosis of individual cholesteatoma cases.
Collapse
MESH Headings
- Adenoma/diagnosis
- Adenoma/pathology
- Adenoma/surgery
- Adult
- Apocrine Glands/pathology
- Apocrine Glands/surgery
- Carcinoma, Squamous Cell/diagnosis
- Carcinoma, Squamous Cell/pathology
- Carcinoma, Squamous Cell/surgery
- Cerumen
- Connective Tissue/pathology
- Connective Tissue/surgery
- Diagnosis, Differential
- Ear Canal/pathology
- Ear Canal/surgery
- Ear Neoplasms/diagnosis
- Ear Neoplasms/pathology
- Ear Neoplasms/surgery
- Ear, Middle/pathology
- Ear, Middle/surgery
- Female
- Hearing Loss, Mixed Conductive-Sensorineural/diagnosis
- Hearing Loss, Mixed Conductive-Sensorineural/surgery
- Humans
- Image Enhancement
- Image Processing, Computer-Assisted
- Imaging, Three-Dimensional
- Magnetic Resonance Imaging
- Mastoid/pathology
- Mastoid/surgery
- Neoplasm Invasiveness
- Sweat Gland Neoplasms/diagnosis
- Sweat Gland Neoplasms/pathology
- Sweat Gland Neoplasms/surgery
- Tomography, X-Ray Computed
- Tympanic Membrane Perforation/diagnosis
- Tympanic Membrane Perforation/surgery
Collapse
|
46
|
Abstract
Mondini dysplasia is a rare malformation of the inner ear commonly associated with loss of hearing and vestibular function. Children with Mondini dysplasia are predisposed to developing a spontaneous cerebrospinal fluid (CSF) leak and recurrent meningitis. If there is no CSF leak but a unilateral hearing loss, the condition may go undiagnosed for years. We describe a 65-year-old man with unrecognized unilateral Mondini dysplasia who presented with CSF leak and meningoencephalitis after minor head trauma. Two operative interventions were undertaken to close the defect properly. Patients with Mondini dysplasia or their parents should be cautioned about the potential hazards of any head trauma.
Collapse
|
47
|
|
48
|
Hereditary Bilateral Conductive Hearing Loss Caused by Total Loss of Ossicles: a Report of Familial Expansile Osteolysis. Otol Neurotol 2005; 26:237-40. [PMID: 15793411 DOI: 10.1097/00129492-200503000-00018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The objective of this study was to report on three members of a family with familial expansile osteolysis; the important point about these patients was that none of them had middle-ear ossicles. STUDY DESIGN AND SUBJECTS A retrospective case review including three cases with familial expansile osteolysis. SETTING Department of Otolaryngology in a tertiary referral center. INTERVENTIONS Each patient underwent computerized tomography of the temporal bone in the coronal view, audiometric and tympanometric evaluations, biochemical investigation, whole body isotope scans by Tc-99 mMDP and X-ray. Also the patients' pedigree was studied. Two of the patients had exploratory middle-ear surgery as well. RESULTS The temporal-bone computed-tomography scan in the coronal view of all three patients and also exploratory middle-ear surgery, which was done on two of the patients, showed no ossicles in the middle ear of either ear in all three cases. This feature hadn't been reported in previous studies. Hearing loss was revealed in the medical histories since childhood. Audiometry indicated mild to moderate conductive and mixed hearing loss and also an AD-type tympanogram pattern along with an absence of acoustic reflexes in both ears of the cases. Both serum alkaline phosphatase and hydroxyproline levels were elevated. There was an increase in uptake and activity at multiple foci of the whole skeleton. No improvement in hearing thresholds was obtained after reconstruction of the middle ear. CONCLUSION The total absence of middle-ear ossicles can probably be regarded as a new symptom in some patients with familial expansile osteolysis. Common ossiculoplasty for improving the hearing thresholds in this condition may be unsuccessful; therefore, both surgeons and patients must be completely aware of the contingent undesirable results.
Collapse
MESH Headings
- Adolescent
- Audiometry, Pure-Tone
- Auditory Threshold
- Carrier Proteins/genetics
- Child
- Chromosome Aberrations
- Chromosomes, Human, Pair 18
- Ear Ossicles/abnormalities
- Female
- Follow-Up Studies
- Genes, Dominant
- Hearing Aids
- Hearing Loss, Bilateral/diagnosis
- Hearing Loss, Bilateral/genetics
- Hearing Loss, Bilateral/surgery
- Hearing Loss, Conductive/diagnosis
- Hearing Loss, Conductive/genetics
- Hearing Loss, Conductive/surgery
- Hearing Loss, Mixed Conductive-Sensorineural/diagnosis
- Hearing Loss, Mixed Conductive-Sensorineural/genetics
- Hearing Loss, Mixed Conductive-Sensorineural/surgery
- Humans
- Male
- Membrane Glycoproteins/genetics
- Middle Aged
- Mutagenesis, Insertional
- Ossicular Prosthesis
- Osteitis Deformans/diagnosis
- Osteitis Deformans/genetics
- Osteitis Deformans/surgery
- Osteolysis, Essential/diagnosis
- Osteolysis, Essential/genetics
- Osteolysis, Essential/surgery
- Pedigree
- RANK Ligand
- Receptor Activator of Nuclear Factor-kappa B
Collapse
|