1
|
Britton KA, Massaro JM, Murabito JM, Kreger BE, Hoffmann U, Fox CS. Body fat distribution, incident cardiovascular disease, cancer, and all-cause mortality. J Am Coll Cardiol 2013; 62:921-5. [PMID: 23850922 DOI: 10.1016/j.jacc.2013.06.027] [Citation(s) in RCA: 486] [Impact Index Per Article: 40.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2012] [Revised: 05/28/2013] [Accepted: 06/18/2013] [Indexed: 01/10/2023]
Abstract
OBJECTIVES The aim of this study was to determine whether ectopic fat depots are prospectively associated with cardiovascular disease, cancer, and all-cause mortality. BACKGROUND The morbidity associated with excess body weight varies among individuals of similar body mass index. Ectopic fat depots may underlie this risk differential. However, prospective studies of directly measured fat are limited. METHODS Participants from the Framingham Heart Study (n = 3,086; 49% women; mean age of 50.2 years) underwent assessment of fat depots (visceral adipose tissue, pericardial adipose tissue, and periaortic adipose tissue) using multidetector computed tomography and were followed up longitudinally for a median of 5.0 years. Cox proportional hazards regression models were used to examine the association of each fat depot (per 1 SD increment) with the risk of incident cardiovascular disease, cancer, and all-cause mortality after adjustment for standard risk factors, including body mass index. RESULTS Overall, there were 90 cardiovascular events, 141 cancer events, and 71 deaths. After multivariable adjustment, visceral adipose tissue was associated with cardiovascular disease (hazard ratio: 1.44; 95% confidence interval: 1.08 to 1.92; p = 0.01) and cancer (hazard ratio: 1.43; 95% confidence interval: 1.12 to 1.84; p = 0.005). Addition of visceral adipose tissue to a multivariable model that included body mass index modestly improved cardiovascular risk prediction (net reclassification improvement of 16.3%). None of the fat depots were associated with all-cause mortality. CONCLUSIONS Visceral adiposity is associated with incident cardiovascular disease and cancer after adjustment for clinical risk factors and generalized adiposity. These findings support the growing appreciation of a pathogenic role of ectopic fat.
Collapse
|
Research Support, N.I.H., Extramural |
12 |
486 |
2
|
Pickhardt PJ, Lee LJ, del Rio AM, Lauder T, Bruce RJ, Summers RM, Pooler BD, Binkley N. Simultaneous screening for osteoporosis at CT colonography: bone mineral density assessment using MDCT attenuation techniques compared with the DXA reference standard. J Bone Miner Res 2011; 26:2194-203. [PMID: 21590738 PMCID: PMC3304444 DOI: 10.1002/jbmr.428] [Citation(s) in RCA: 230] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The purpose of this study was to evaluate the utility of lumbar spine attenuation measurement for bone mineral density (BMD) assessment at screening computed tomographic colonography (CTC) using central dual-energy X-ray absorptiometry (DXA) as the reference standard. Two-hundred and fifty-two adults (240 women and 12 men; mean age 58.9 years) underwent CTC screening and central DXA BMD measurement within 2 months (mean interval 25.0 days). The lowest DXA T-score between the spine and hip served as the reference standard, with low BMD defined per World Health Organization as osteoporosis (DXA T-score ≤ -2.5) or osteopenia (DXA T-score between -1.0 and -2.4). Both phantomless quantitative computed tomography (QCT) and simple nonangled region-of-interest (ROI) multi-detector CT (MDCT) attenuation measurements were applied to the T(12) -L(5) levels. The ability to predict osteoporosis and low BMD (osteoporosis or osteopenia) by DXA was assessed. A BMD cut-off of 90 mg/mL at phantomless QCT yielded 100% sensitivity for osteoporosis (29 of 29) and a specificity of 63.8% (143 of 224); 87.2% (96 of 110) below this threshold had low BMD and 49.6% (69 of 139) above this threshold had normal BMD at DXA. At L(1) , a trabecular ROI attenuation cut-off of 160 HU was 100% sensitive for osteoporosis (29 of 29), with a specificity of 46.4% (104 of 224); 83.9% (125 of 149) below this threshold had low BMD and 57.5% (59/103) above had normal BMD at DXA. ROI performance was similar at all individual T(12) -L(5) levels. At ROC analysis, AUC for osteoporosis was 0.888 for phantomless QCT [95% confidence interval (CI) 0.780-0.946] and ranged from 0.825 to 0.853 using trabecular ROIs at single lumbar levels (0.864; 95% CI 0.752-0.930 at multivariate analysis). Supine-prone reproducibility was better with the simple ROI method compared with QCT. It is concluded that both phantomless QCT and simple ROI attenuation measurements of the lumbar spine are effective for BMD screening at CTC with high sensitivity for osteoporosis, as defined by the DXA T-score.
Collapse
|
Comparative Study |
14 |
230 |
3
|
Tilsed JVT, Casamassima A, Kurihara H, Mariani D, Martinez I, Pereira J, Ponchietti L, Shamiyeh A, Al-Ayoubi F, Barco LAB, Ceolin M, D'Almeida AJG, Hilario S, Olavarria AL, Ozmen MM, Pinheiro LF, Poeze M, Triantos G, Fuentes FT, Sierra SU, Soreide K, Yanar H. ESTES guidelines: acute mesenteric ischaemia. Eur J Trauma Emerg Surg 2016; 42:253-70. [PMID: 26820988 PMCID: PMC4830881 DOI: 10.1007/s00068-016-0634-0] [Citation(s) in RCA: 203] [Impact Index Per Article: 22.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
PURPOSE Acute mesenteric ischaemia (AMI) accounts for about 1:1000 acute hospital admissions. Untreated, AMI will cause mesenteric infarction, intestinal necrosis, an overwhelming inflammatory response and death. Early intervention can halt and reverse this process leading to a full recovery, but the diagnosis of AMI is difficult and failure to recognize AMI before intestinal necrosis has developed is responsible for the high mortality of the disease. Early diagnosis and prompt treatment are the goals of modern therapy, but there are no randomized controlled trials to guide treatment and the published literature contains a high ratio of reviews to original data. Much of that data comes from case reports and often small, retrospective series with no clearly defined treatment criteria. METHODS A study group of the European Society for Trauma and Emergency Surgery (ESTES) was formed in 2013 with the aim of developing guidelines for the management of AMI. A comprehensive literature search was performed using the Medical Subject Heading (MeSH) thesaurus keywords "mesenteric ischaemia", "bowel ischaemia" and "bowel infarction". The bibliographies of relevant articles were screened for additional publications. After an initial systematic review of the literature by the whole group, a steering group formulated questions using a modified Delphi process. The evidence was then reviewed to answer these questions, and recommendations formulated and agreed by the whole group. RESULTS The resultant recommendations are presented in this paper. CONCLUSIONS The aim of these guidelines is to provide recommendations for practice that will lead to improved outcomes for patients.
Collapse
|
Practice Guideline |
9 |
203 |
4
|
Tatsugami F, Higaki T, Nakamura Y, Yu Z, Zhou J, Lu Y, Fujioka C, Kitagawa T, Kihara Y, Iida M, Awai K. Deep learning-based image restoration algorithm for coronary CT angiography. Eur Radiol 2019; 29:5322-5329. [PMID: 30963270 DOI: 10.1007/s00330-019-06183-y] [Citation(s) in RCA: 172] [Impact Index Per Article: 28.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 03/09/2019] [Accepted: 03/19/2019] [Indexed: 12/22/2022]
Abstract
OBJECTIVES The purpose of this study was to compare the image quality of coronary computed tomography angiography (CTA) subjected to deep learning-based image restoration (DLR) method with images subjected to hybrid iterative reconstruction (IR). METHODS We enrolled 30 patients (22 men, 8 women) who underwent coronary CTA on a 320-slice CT scanner. The images were reconstructed with hybrid IR and with DLR. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured on all images and the contrast-to-noise ratio (CNR) in the proximal coronary arteries was calculated. We also generated CT attenuation profiles across the proximal coronary arteries and measured the width of the edge rise distance (ERD) and the edge rise slope (ERS). Two observers visually evaluated the overall image quality using a 4-point scale (1 = poor, 4 = excellent). RESULTS On DLR images, the mean image noise was lower than that on hybrid IR images (18.5 ± 2.8 HU vs. 23.0 ± 4.6 HU, p < 0.01) and the CNR was significantly higher (p < 0.01). The mean ERD was significantly shorter on DLR than on hybrid IR images, whereas the mean ERS was steeper on DLR than on hybrid IR images. The mean image quality score for hybrid IR and DLR images was 2.96 and 3.58, respectively (p < 0.01). CONCLUSIONS DLR reduces the image noise and improves the image quality at coronary CTA. KEY POINTS • Deep learning-based image restoration is a new technique that employs the deep convolutional neural network for image quality improvement. • Deep learning-based restoration reduces the image noise and improves image quality at coronary CT angiography. • This method may allow for a reduction in radiation exposure.
Collapse
|
Journal Article |
6 |
172 |
5
|
Desjardins L, Liabeuf S, Renard C, Lenglet A, Lemke HD, Choukroun G, Drueke TB, Massy ZA. FGF23 is independently associated with vascular calcification but not bone mineral density in patients at various CKD stages. Osteoporos Int 2012; 23:2017-25. [PMID: 22109743 DOI: 10.1007/s00198-011-1838-0] [Citation(s) in RCA: 159] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2011] [Accepted: 08/25/2011] [Indexed: 02/01/2023]
Abstract
SUMMARY The hormone fibroblast growth factor 23 (FGF23) is involved in mineral homeostasis but may also have a role in vascular calcification and bone mineralization. In a cohort of 142 patients with CKD stages 2-5D, plasma FGF23 was independently associated with aortic calcification but not with pulse wave velocity or bone mineral density. INTRODUCTION FGF23 is involved in mineral homeostasis but may also have a role in vascular calcification and bone mineralization. Previous studies related to FGF23 and vascular and bone outcomes have been restricted to dialysis patients. The aim of the present study was to establish whether or not plasma FGF23 is associated with aortic and coronary calcification, arterial stiffness, and bone mineral density in patients with early as well as late stages of CKD. METHODS In a cohort of 142 patients with CKD stages 2-5D, we made routine biochemistry and intact FGF23 determinations, and assessed aortic and coronary calcification, bone mineral density (BMD), and arterial stiffness by multislice spiral computed tomography and automated pulse wave velocity (PWV). RESULTS Plasma intact FGF23 levels were elevated in CKD patients; the elevation preceded that of serum phosphate in early-stage CKD. Patients with elevated FGF23 levels had higher aortic and coronary calcification scores than patients with lower FGF23 levels. Multivariate linear regression analysis indicated that only age (p < 0.001) and FGF23 (p = 0.008) were independently associated with aortic calcification score. Plasma FGF23 was neither associated with PWV nor with BMD. CONCLUSION Our data suggest that plasma FGF23 is an independent biomarker of vascular calcification in patients with various CKD stages including early stages. The association between vascular calcification and FGF23 levels appears to be independent of BMD. It remains to be seen whether this association is independent of bone turnover and bone mass.
Collapse
|
|
13 |
159 |
6
|
Francone M, Budde RPJ, Bremerich J, Dacher JN, Loewe C, Wolf F, Natale L, Pontone G, Redheuil A, Vliegenthart R, Nikolaou K, Gutberlet M, Salgado R. CT and MR imaging prior to transcatheter aortic valve implantation: standardisation of scanning protocols, measurements and reporting-a consensus document by the European Society of Cardiovascular Radiology (ESCR). Eur Radiol 2019; 30:2627-2650. [PMID: 31489471 PMCID: PMC7160220 DOI: 10.1007/s00330-019-06357-8] [Citation(s) in RCA: 146] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 05/29/2019] [Accepted: 07/03/2019] [Indexed: 01/04/2023]
Abstract
Abstract Transcatheter aortic valve replacement (TAVR) is a minimally invasive alternative to conventional aortic valve replacement in symptomatic patients with severe aortic stenosis and contraindications to surgery. The procedure has shown to improve patient’s quality of life and prolong short- and mid-term survival in high-risk individuals, becoming a widely accepted therapeutic option which has been integrated into current clinical guidelines for the management of valvular heart disease. Nevertheless, not every patient at high-risk for surgery is a good candidate for TAVR. Besides clinical selection, which is usually established by the Heart Team, certain technical and anatomic criteria must be met as, unlike in surgical valve replacement, annular sizing is not performed under direct surgical evaluation but on the basis of non-invasive imaging findings. Present consensus document was outlined by a working group of researchers from the European Society of Cardiovascular Radiology (ESCR) and aims to provide guidance on the utilisation of CT and MR imaging prior to TAVR. Particular relevance is given to the technical requirements and standardisation of the scanning protocols which have to be tailored to the remarkable variability of the scanners currently utilised in clinical practice; recommendations regarding all required pre-procedural measurements and medical reporting standardisation have been also outlined, in order to ensure quality and consistency of reported data and terminology. Key Points • To provide a reference document for CT and MR acquisition techniques, taking into account the significant technological variation of available scanners. • To review all relevant measurements that are required and define a step-by-step guided approach for the measurements of different structures implicated in the procedure. • To propose a CT/MR reporting template to assist in consistent communication between various sites and specialists involved in the procedural planning. Electronic supplementary material The online version of this article (10.1007/s00330-019-06357-8) contains supplementary material, which is available to authorized users.
Collapse
|
Video-Audio Media |
6 |
146 |
7
|
Al’Aref SJ, Maliakal G, Singh G, van Rosendael AR, Ma X, Xu Z, Alawamlh OAH, Lee B, Pandey M, Achenbach S, Al-Mallah MH, Andreini D, Bax JJ, Berman DS, Budoff MJ, Cademartiri F, Callister TQ, Chang HJ, Chinnaiyan K, Chow BJW, Cury RC, DeLago A, Feuchtner G, Hadamitzky M, Hausleiter J, Kaufmann PA, Kim YJ, Leipsic JA, Maffei E, Marques H, Gonçalves PDA, Pontone G, Raff GL, Rubinshtein R, Villines TC, Gransar H, Lu Y, Jones EC, Peña JM, Lin FY, Min JK, Shaw LJ. Machine learning of clinical variables and coronary artery calcium scoring for the prediction of obstructive coronary artery disease on coronary computed tomography angiography: analysis from the CONFIRM registry. Eur Heart J 2020; 41:359-367. [PMID: 31513271 PMCID: PMC7849944 DOI: 10.1093/eurheartj/ehz565] [Citation(s) in RCA: 135] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 03/19/2019] [Accepted: 08/20/2019] [Indexed: 12/21/2022] Open
Abstract
AIMS Symptom-based pretest probability scores that estimate the likelihood of obstructive coronary artery disease (CAD) in stable chest pain have moderate accuracy. We sought to develop a machine learning (ML) model, utilizing clinical factors and the coronary artery calcium score (CACS), to predict the presence of obstructive CAD on coronary computed tomography angiography (CCTA). METHODS AND RESULTS The study screened 35 281 participants enrolled in the CONFIRM registry, who underwent ≥64 detector row CCTA evaluation because of either suspected or previously established CAD. A boosted ensemble algorithm (XGBoost) was used, with data split into a training set (80%) on which 10-fold cross-validation was done and a test set (20%). Performance was assessed of the (1) ML model (using 25 clinical and demographic features), (2) ML + CACS, (3) CAD consortium clinical score, (4) CAD consortium clinical score + CACS, and (5) updated Diamond-Forrester (UDF) score. The study population comprised of 13 054 patients, of whom 2380 (18.2%) had obstructive CAD (≥50% stenosis). Machine learning with CACS produced the best performance [area under the curve (AUC) of 0.881] compared with ML alone (AUC of 0.773), CAD consortium clinical score (AUC of 0.734), and with CACS (AUC of 0.866) and UDF (AUC of 0.682), P < 0.05 for all comparisons. CACS, age, and gender were the highest ranking features. CONCLUSION A ML model incorporating clinical features in addition to CACS can accurately estimate the pretest likelihood of obstructive CAD on CCTA. In clinical practice, the utilization of such an approach could improve risk stratification and help guide downstream management.
Collapse
|
Multicenter Study |
5 |
135 |
8
|
Douglas PS, Hoffmann U, Lee KL, Mark DB, Al-Khalidi HR, Anstrom K, Dolor RJ, Kosinski A, Krucoff MW, Mudrick DW, Patel MR, Picard MH, Udelson JE, Velazquez EJ, Cooper L. PROspective Multicenter Imaging Study for Evaluation of chest pain: rationale and design of the PROMISE trial. Am Heart J 2014; 167:796-803.e1. [PMID: 24890527 PMCID: PMC4044617 DOI: 10.1016/j.ahj.2014.03.003] [Citation(s) in RCA: 102] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Accepted: 03/05/2014] [Indexed: 12/24/2022]
Abstract
BACKGROUND Suspected coronary artery disease (CAD) is one of the most common, potentially life-threatening diagnostic problems clinicians encounter. However, no large outcome-based randomized trials have been performed to guide the selection of diagnostic strategies for these patients. METHODS The PROMISE study is a prospective, randomized trial comparing the effectiveness of 2 initial diagnostic strategies in patients with symptoms suspicious for CAD. Patients are randomized to either (1) functional testing (exercise electrocardiogram, stress nuclear imaging, or stress echocardiogram) or (2) anatomical testing with ≥64-slice multidetector coronary computed tomographic angiography. Tests are interpreted locally in real time by subspecialty certified physicians, and all subsequent care decisions are made by the clinical care team. Sites are provided results of central core laboratory quality and completeness assessment. All subjects are followed up for ≥1 year. The primary end point is the time to occurrence of the composite of death, myocardial infarction, major procedural complications (stroke, major bleeding, anaphylaxis, and renal failure), or hospitalization for unstable angina. RESULTS More than 10,000 symptomatic subjects were randomized in 3.2 years at 193 US and Canadian cardiology, radiology, primary care, urgent care, and anesthesiology sites. CONCLUSION Multispecialty community practice enrollment into a large pragmatic trial of diagnostic testing strategies is both feasible and efficient. The PROMISE trial will compare the clinical effectiveness of an initial strategy of functional testing against an initial strategy of anatomical testing in symptomatic patients with suspected CAD. Quality of life, resource use, cost-effectiveness, and radiation exposure will be assessed.
Collapse
|
Comparative Study |
11 |
102 |
9
|
Fan L, Fang M, Li Z, Tu W, Wang S, Chen W, Tian J, Dong D, Liu S. Radiomics signature: a biomarker for the preoperative discrimination of lung invasive adenocarcinoma manifesting as a ground-glass nodule. Eur Radiol 2018; 29:889-897. [PMID: 29967956 DOI: 10.1007/s00330-018-5530-z] [Citation(s) in RCA: 97] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 04/03/2018] [Accepted: 05/07/2018] [Indexed: 12/20/2022]
Abstract
OBJECTIVES To identify the radiomics signature allowing preoperative discrimination of lung invasive adenocarcinomas from non-invasive lesions manifesting as ground-glass nodules. METHODS This retrospective primary cohort study included 160 pathologically confirmed lung adenocarcinomas. Radiomics features were extracted from preoperative non-contrast CT images to build a radiomics signature. The predictive performance and calibration of the radiomics signature were evaluated using intra-cross (n=76), external non-contrast-enhanced CT (n=75) and contrast-enhanced CT (n=84) validation cohorts. The performance of radiomics signature and CT morphological and quantitative indices were compared. RESULTS 355 three-dimensional radiomics features were extracted, and two features were identified as the best discriminators to build a radiomics signature. The radiomics signature showed a good ability to discriminate between invasive adenocarcinomas and non-invasive lesions with an accuracy of 86.3%, 90.8%, 84.0% and 88.1%, respectively, in the primary and validation cohorts. It remained an independent predictor after adjusting for traditional preoperative factors (odds ratio 1.87, p < 0.001) and demonstrated good calibration in all cohorts. It was a better independent predictor than CT morphology or mean CT value. CONCLUSIONS The radiomics signature showed good predictive performance in discriminating between invasive adenocarcinomas and non-invasive lesions. Being a non-invasive biomarker, it could assist in determining therapeutic strategies for lung adenocarcinoma. KEY POINTS • The radiomics signature was a non-invasive biomarker of lung invasive adenocarcinoma. • The radiomics signature outweighed CT morphological and quantitative indices. • A three-centre study showed that radiomics signature had good predictive performance.
Collapse
|
Journal Article |
7 |
97 |
10
|
Ghekiere O, Salgado R, Buls N, Leiner T, Mancini I, Vanhoenacker P, Dendale P, Nchimi A. Image quality in coronary CT angiography: challenges and technical solutions. Br J Radiol 2017; 90:20160567. [PMID: 28055253 PMCID: PMC5605061 DOI: 10.1259/bjr.20160567] [Citation(s) in RCA: 95] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Revised: 10/13/2016] [Accepted: 01/03/2017] [Indexed: 11/05/2022] Open
Abstract
Multidetector CT angiography (CTA) has become a widely accepted examination for non-invasive evaluation of the heart and coronary arteries. Despite its ongoing success and worldwide clinical implementation, it remains an often-challenging procedure in which image quality, and hence diagnostic value, is determined by both technical and patient-related factors. Thorough knowledge of these factors is important to obtain high-quality examinations. In this review, we discuss several key elements that may adversely affect coronary CTA image quality as well as potential measures that can be taken to mitigate their impact. In addition, several recent vendor-specific advances and future directions to improve image quality are discussed.
Collapse
|
Review |
8 |
95 |
11
|
Mehta A, Vasquez N, Ayers CR, Patel J, Hooda A, Khera A, Blumenthal RS, Shapiro MD, Rodriguez CJ, Tsai MY, Sperling LS, Virani SS, Blaha MJ, Joshi PH. Independent Association of Lipoprotein(a) and Coronary Artery Calcification With Atherosclerotic Cardiovascular Risk. J Am Coll Cardiol 2022; 79:757-768. [PMID: 35210030 PMCID: PMC10966924 DOI: 10.1016/j.jacc.2021.11.058] [Citation(s) in RCA: 90] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 11/22/2021] [Indexed: 12/24/2022]
Abstract
BACKGROUND Elevated lipoprotein(a) [Lp(a)] and coronary artery calcium (CAC) score are individually associated with increased atherosclerotic cardiovascular disease (ASCVD) risk but have not been studied in combination. OBJECTIVES This study sought to investigate the independent and joint association of Lp(a) and CAC with ASCVD risk. METHODS Plasma Lp(a) and CAC were measured at enrollment among asymptomatic participants of the MESA (Multi-Ethnic Study of Atherosclerosis) (n = 4,512) and DHS (Dallas Heart Study) (n = 2,078) cohorts. Elevated Lp(a) was defined as the highest race-specific quintile, and 3 CAC score categories were studied (0, 1-99, and ≥100). Associations of Lp(a) and CAC with ASCVD risk were evaluated using risk factor-adjusted Cox regression models. RESULTS Among MESA participants (61.9 years of age, 52.5% women, 36.8% White, 29.3% Black, 22.2% Hispanic, and 11.7% Chinese), 476 incident ASCVD events were observed during 13.2 years of follow-up. Elevated Lp(a) and CAC score (1-99 and ≥100) were independently associated with ASCVD risk (HR: 1.29; 95% CI: 1.04-1.61; HR: 1.68; 95% CI: 1.30-2.16; and HR: 2.66; 95% CI: 2.07-3.43, respectively), and Lp(a)-by-CAC interaction was not noted. Compared with participants with nonelevated Lp(a) and CAC = 0, those with elevated Lp(a) and CAC ≥100 were at the highest risk (HR: 4.71; 95% CI: 3.01-7.40), and those with elevated Lp(a) and CAC = 0 were at a similar risk (HR: 1.31; 95% CI: 0.73-2.35). Similar findings were observed when guideline-recommended Lp(a) and CAC thresholds were considered, and findings were replicated in the DHS. CONCLUSIONS Lp(a) and CAC are independently associated with ASCVD risk and may be useful concurrently for guiding primary prevention therapy decisions.
Collapse
|
Research Support, N.I.H., Extramural |
3 |
90 |
12
|
Cheezum MK, Ghoshhajra B, Bittencourt MS, Hulten EA, Bhatt A, Mousavi N, Shah NR, Valente AM, Rybicki FJ, Steigner M, Hainer J, MacGillivray T, Hoffmann U, Abbara S, Di Carli MF, DeFaria Yeh D, Landzberg M, Liberthson R, Blankstein R. Anomalous origin of the coronary artery arising from the opposite sinus: prevalence and outcomes in patients undergoing coronary CTA. Eur Heart J Cardiovasc Imaging 2017; 18:224-235. [PMID: 26848152 PMCID: PMC6279103 DOI: 10.1093/ehjci/jev323] [Citation(s) in RCA: 90] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2015] [Accepted: 11/15/2015] [Indexed: 12/16/2022] Open
Abstract
AIMS The impact of coronary computed tomographic angiography (CTA) on management of anomalous origin of the coronary artery arising from the opposite sinus (ACAOS) remains uncertain. We examined the prevalence, anatomical characterization, and outcomes of ACAOS patients undergoing CTA. METHODS AND RESULTS Among 5991 patients referred for CTA at two tertiary hospitals between January 2004 and June 2014, we identified 103 patients (1.7% prevalence) with 110 ACAOS vessels. Mean age was 52 years (range 5-83, 63% male), with 55% previously known ACAOS and 45% discovered on CTA. ACAOS subtypes included: 39% interarterial (n = 40 anomalous right coronary artery, n = 3 anomalous left coronary artery), 38% retroaortic, 15% subpulmonic, 5% prepulmonic, and 2% other. ACAOS patients were assessed for symptoms, ischaemic test results, revascularization, all-cause or cardiovascular (CV) death, and myocardial infarction. CTAs were reviewed for ACAOS course, take-off height and angle, length and severity of proximal narrowing, intramural course, and obstructive coronary artery disease (CAD). In follow-up (median 5.8 years), there were 20 surgical revascularizations and 3 CV deaths. After adjusting for obstructive CAD (n = 21/103, 20%), variables associated with ACAOS revascularization included the following: CV symptoms, proximal vessel narrowing ≥50%, length of narrowing >5.4 mm, and an interarterial course. CONCLUSION The prevalence of ACAOS on CTA was 1.7%, including 45% of cases discovered incidentally. CTA provided excellent characterization of ACAOS features associated with coronary revascularization, including the length and severity of proximal vessel narrowing.
Collapse
|
Comparative Study |
8 |
90 |
13
|
Ghaneh P, Hanson R, Titman A, Lancaster G, Plumpton C, Lloyd-Williams H, Yeo ST, Edwards RT, Johnson C, Abu Hilal M, Higginson AP, Armstrong T, Smith A, Scarsbrook A, McKay C, Carter R, Sutcliffe RP, Bramhall S, Kocher HM, Cunningham D, Pereira SP, Davidson B, Chang D, Khan S, Zealley I, Sarker D, Al Sarireh B, Charnley R, Lobo D, Nicolson M, Halloran C, Raraty M, Sutton R, Vinjamuri S, Evans J, Campbell F, Deeks J, Sanghera B, Wong WL, Neoptolemos JP. PET-PANC: multicentre prospective diagnostic accuracy and health economic analysis study of the impact of combined modality 18fluorine-2-fluoro-2-deoxy-d-glucose positron emission tomography with computed tomography scanning in the diagnosis and management of pancreatic cancer. Health Technol Assess 2018; 22:1-114. [PMID: 29402376 PMCID: PMC5817411 DOI: 10.3310/hta22070] [Citation(s) in RCA: 80] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND Pancreatic cancer diagnosis and staging can be difficult in 10-20% of patients. Positron emission tomography (PET)/computed tomography (CT) adds precise anatomical localisation to functional data. The use of PET/CT may add further value to the diagnosis and staging of pancreatic cancer. OBJECTIVE To determine the incremental diagnostic accuracy and impact of PET/CT in addition to standard diagnostic work-up in patients with suspected pancreatic cancer. DESIGN A multicentre prospective diagnostic accuracy and clinical value study of PET/CT in suspected pancreatic malignancy. PARTICIPANTS Patients with suspected pancreatic malignancy. INTERVENTIONS All patients to undergo PET/CT following standard diagnostic work-up. MAIN OUTCOME MEASURES The primary outcome was the incremental diagnostic value of PET/CT in addition to standard diagnostic work-up with multidetector computed tomography (MDCT). Secondary outcomes were (1) changes in patients' diagnosis, staging and management as a result of PET/CT; (2) changes in the costs and effectiveness of patient management as a result of PET/CT; (3) the incremental diagnostic value of PET/CT in chronic pancreatitis; (4) the identification of groups of patients who would benefit most from PET/CT; and (5) the incremental diagnostic value of PET/CT in other pancreatic tumours. RESULTS Between 2011 and 2013, 589 patients with suspected pancreatic cancer underwent MDCT and PET/CT, with 550 patients having complete data and in-range PET/CT. Sensitivity and specificity for the diagnosis of pancreatic cancer were 88.5% and 70.6%, respectively, for MDCT and 92.7% and 75.8%, respectively, for PET/CT. The maximum standardised uptake value (SUVmax.) for a pancreatic cancer diagnosis was 7.5. PET/CT demonstrated a significant improvement in relative sensitivity (p = 0.01) and specificity (p = 0.023) compared with MDCT. Incremental likelihood ratios demonstrated that PET/CT significantly improved diagnostic accuracy in all scenarios (p < 0.0002). PET/CT correctly changed the staging of pancreatic cancer in 56 patients (p = 0.001). PET/CT influenced management in 250 (45%) patients. PET/CT stopped resection in 58 (20%) patients who were due to have surgery. The benefit of PET/CT was limited in patients with chronic pancreatitis or other pancreatic tumours. PET/CT was associated with a gain in quality-adjusted life-years of 0.0157 (95% confidence interval -0.0101 to 0.0430). In the base-case model PET/CT was seen to dominate MDCT alone and is thus highly likely to be cost-effective for the UK NHS. PET/CT was seen to be most cost-effective for the subgroup of patients with suspected pancreatic cancer who were thought to be resectable. CONCLUSION PET/CT provided a significant incremental diagnostic benefit in the diagnosis of pancreatic cancer and significantly influenced the staging and management of patients. PET/CT had limited utility in chronic pancreatitis and other pancreatic tumours. PET/CT is likely to be cost-effective at current reimbursement rates for PET/CT to the UK NHS. This was not a randomised controlled trial and therefore we do not have any information from patients who would have undergone MDCT only for comparison. In addition, there were issues in estimating costs for PET/CT. Future work should evaluate the role of PET/CT in intraductal papillary mucinous neoplasm and prognosis and response to therapy in patients with pancreatic cancer. STUDY REGISTRATION Current Controlled Trials ISRCTN73852054 and UKCRN 8166. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
|
Comparative Study |
7 |
80 |
14
|
Wang W, Shpaner A, Krishna SG, Ross WA, Bhutani MS, Tamm EP, Raju GS, Xiao L, Wolff RA, Fleming JB, Lee JH. Use of EUS-FNA in diagnosing pancreatic neoplasm without a definitive mass on CT. Gastrointest Endosc 2013; 78:73-80. [PMID: 23523302 DOI: 10.1016/j.gie.2013.01.040] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2012] [Accepted: 01/29/2013] [Indexed: 02/08/2023]
Abstract
BACKGROUND Diagnosis of pancreatic neoplasm is challenging in patients with inconclusive findings on pancreatic multidetector row CT (MDCT). OBJECTIVE To determine the diagnostic accuracy and to identify predictors of pancreatic neoplasm by EUS with FNA in this setting. DESIGN Retrospective chart review during the study period of January 2002 to December 2010. SETTING Tertiary referral center. PATIENTS Of the 1046 patients who underwent pancreatic EUS, 116 patients were selected because their clinical presentation was suspicious for pancreatic malignancy, but their MDCT findings were inconclusive. INTERVENTION EUS with FNA. MAIN OUTCOME MEASUREMENTS Diagnostic yield of malignancy and significance of clinical variables. RESULTS When surgical pathology or subsequent clinical course was used as the criterion standard, EUS with FNA had a sensitivity, specificity, positive predictive value, and accuracy of 87.3%, 98.3%, 98.5%, and 92.1%, respectively, in diagnosing a pancreatic neoplasm that was indeterminate on MDCT. Factors significantly associated with EUS detection of pancreatic ductal adenocarcinoma were total bilirubin level greater than 2 mg/dL (P < .001), CT finding of pancreatic duct dilation (P < .001), bile duct stricture (P < .001), and tumor size 1.5 cm or larger detected by EUS (P = .004). Among them, pancreatic duct dilation on CT (odds ratio 4.10; 95% confidence interval, 1.52-11.05), and tumor size 1.5 cm or larger detected by EUS (odds ratio 8.46; 95% confidence interval, 2.02-35.45) were independent risk factors. LIMITATIONS Retrospective design and patient referral bias. CONCLUSIONS When MDCT is indeterminate, EUS is a highly sensitive and accurate modality for the detection of pancreatic neoplasm, especially when the tumor is smaller than 2.0 cm.
Collapse
|
|
12 |
75 |
15
|
McNamara MM, Little MD, Alexander LF, Carroll LV, Beasley TM, Morgan DE. Multireader evaluation of lesion conspicuity in small pancreatic adenocarcinomas: complimentary value of iodine material density and low keV simulated monoenergetic images using multiphasic rapid kVp-switching dual energy CT. ACTA ACUST UNITED AC 2016; 40:1230-40. [PMID: 25331567 DOI: 10.1007/s00261-014-0274-y] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVE Perform multireader analysis of objective and subjective lesion conspicuity for small pancreatic adenocarcinomas using rapid switching dual energy CT (rsDECT). MATERIALS AND METHODS With IRB approval, 51 abdominal multiphasic rsDECT scans in 46 subjects with small (<3 cm) pancreatic adenocarcinomas were retrospectively reviewed by three independent readers for objective and subjective lesion conspicuity. Measured variables during individual, blinded interpretive sessions of separate low (52) keV, PACS-equivalent (70) keV, and iodine material density (MD) image sets included Hounsfield units (HU) and mg/cc iodine for tumor, nontumoral pancreas, and subcutaneous fat. Objective measures included absolute lesion contrast (LC) and contrast to noise ratios (CNR). Subjective measures included image quality, lesion conspicuity, and reader confidence. Reader agreement was measured with kappa statistic; correlation with truth by Pearson coefficient, CNR with repeated mANOVA; subjective quality measures utilized Tukey-Cramer corrections for multiple testing, p < 0.05 considered significant. RESULTS Demographics: 26 F, 20 M, mean age 68 years, weight 75 kg, tumor size of 2.3 cm. LC was highest on 52 keV images for all three readers (mean 90.1 HU). Mean CNR for iodine MD images (4.87) was significantly higher than 52 keV (4.13) or 70 keV (3.9). Very high to near-perfect kappa values were observed for all individual measured objective variables but were best for 52 keV images (52 keV 0.89-0.95, 70 keV 0.76-0.83, iodine 0.87-0.92). 70 keV images scored best for subjective image quality; iodine MD images scored best for lesion conspicuity and reader confidence. CONCLUSION We observed very high reader agreement for independent objective rsDECT image variables and subjective rsDECT image scores in patients with small pancreatic adenocarcinomas. Maximal objective tumor to nontumoral LC was depicted on 52 keV and highest CNR on iodine MD images; readers scored the iodine MD images best for lesion conspicuity and confidence.
Collapse
|
Journal Article |
9 |
70 |
16
|
Pickhardt PJ, Malecki K, Kloke J, Lubner MG. Accuracy of Liver Surface Nodularity Quantification on MDCT as a Noninvasive Biomarker for Staging Hepatic Fibrosis. AJR Am J Roentgenol 2016; 207:1194-1199. [PMID: 27575867 DOI: 10.2214/ajr.16.16514] [Citation(s) in RCA: 68] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
Abstract
OBJECTIVE The purpose of this study was to investigate objective semiautomated measurement of liver surface nodularity on MDCT for prediction of underlying hepatic fibrosis (stages F0-F4). MATERIALS AND METHODS Contrast-enhanced abdominal MDCT scans were assessed with an independently validated semiautomated surface nodularity tool. A series of 10 or more consecutive ROI measurements along the anterior aspect of the liver totaling a length of 80 cm or more were made with the left lateral segment as the default. All intermediate stages of fibrosis (F1-F3) were based on liver biopsy results within 1 year of MDCT. RESULTS The study participants were 367 patients (191 men, 176 women; mean age, 51.1 years) divided into a healthy (F0) control group (n = 118) and patients with fibrosis in stages F1 (n = 47), F2 (n = 38), F3 (n = 67), and F4, which constituted cirrhosis (n = 97). MDCT-based liver surface nodularity scores increased with stage of fibrosis: F0, 2.01 ± 0.28; F1, 2.34 ± 0.39; F2, 2.37 ± 0.39; F3, 2.88 ± 0.68; and F4, 4.11 ± 0.95. For discriminating significant fibrosis (≥ F2), advanced fibrosis (≥ F3), and cirrhosis (≥ F4), the ROC AUCs were 0.902, 0.932, and 0.959, respectively. The sensitivity and specificity for significant fibrosis (≥ F2; liver surface nodularity threshold, 2.38) were 80.2% and 80.0%, for advanced fibrosis (≥ F3; liver surface nodularity threshold, 2.53) were 89.0% and 84.2%, and for cirrhosis (≥ F4; liver surface nodularity threshold, 2.81) were 97.9% and 84.8%. CONCLUSION Objective quantification of liver surface nodularity at MDCT allows accurate discrimination between stages of hepatic fibrosis, especially at more advanced levels. Although the results are comparable to those of elastography, this simple semiautomated biomarker can be measured retrospectively without additional equipment or patient time.
Collapse
|
|
9 |
68 |
17
|
Ilangovan R, Burling D, George A, Gupta A, Marshall M, Taylor SA. CT enterography: review of technique and practical tips. Br J Radiol 2012; 85:876-86. [PMID: 22553291 PMCID: PMC3474054 DOI: 10.1259/bjr/27973476] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2011] [Revised: 12/01/2011] [Accepted: 12/06/2011] [Indexed: 02/06/2023] Open
Abstract
CT enterography is a new non-invasive imaging technique that offers superior small bowel visualisation compared with standard abdomino-pelvic CT, and provides complementary diagnostic information to capsule endoscopy and MRI enterography. CT enterography is well tolerated by patients and enables accurate, efficient assessment of pathology arising from the small bowel wall or surrounding organs. This article reviews the clinical role of CT enterography, and offers practical tips for optimising technique and accurate interpretation.
Collapse
|
Comparative Study |
13 |
66 |
18
|
Zhang HT, Zhang JS, Zhang HH, Nan YD, Zhao Y, Fu EQ, Xie YH, Liu W, Li WP, Zhang HJ, Jiang H, Li CM, Li YY, Ma RN, Dang SK, Gao BB, Zhang XJ, Zhang T. Automated detection and quantification of COVID-19 pneumonia: CT imaging analysis by a deep learning-based software. Eur J Nucl Med Mol Imaging 2020; 47:2525-2532. [PMID: 32666395 PMCID: PMC7358997 DOI: 10.1007/s00259-020-04953-1] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 07/05/2020] [Indexed: 01/08/2023]
Abstract
BACKGROUND The novel coronavirus disease 2019 (COVID-19) is an emerging worldwide threat to public health. While chest computed tomography (CT) plays an indispensable role in its diagnosis, the quantification and localization of lesions cannot be accurately assessed manually. We employed deep learning-based software to aid in detection, localization and quantification of COVID-19 pneumonia. METHODS A total of 2460 RT-PCR tested SARS-CoV-2-positive patients (1250 men and 1210 women; mean age, 57.7 ± 14.0 years (age range, 11-93 years) were retrospectively identified from Huoshenshan Hospital in Wuhan from February 11 to March 16, 2020. Basic clinical characteristics were reviewed. The uAI Intelligent Assistant Analysis System was used to assess the CT scans. RESULTS CT scans of 2215 patients (90%) showed multiple lesions of which 36 (1%) and 50 patients (2%) had left and right lung infections, respectively (> 50% of each affected lung's volume), while 27 (1%) had total lung infection (> 50% of the total volume of both lungs). Overall, 298 (12%), 778 (32%) and 1300 (53%) patients exhibited pure ground glass opacities (GGOs), GGOs with sub-solid lesions and GGOs with both sub-solid and solid lesions, respectively. Moreover, 2305 (94%) and 71 (3%) patients presented primarily with GGOs and sub-solid lesions, respectively. Elderly patients (≥ 60 years) were more likely to exhibit sub-solid lesions. The generalized linear mixed model showed that the dorsal segment of the right lower lobe was the favoured site of COVID-19 pneumonia. CONCLUSION Chest CT combined with analysis by the uAI Intelligent Assistant Analysis System can accurately evaluate pneumonia in COVID-19 patients.
Collapse
|
Research Support, Non-U.S. Gov't |
5 |
61 |
19
|
Yan RT, Miller JM, Rochitte CE, Dewey M, Niinuma H, Clouse ME, Vavere AL, Brinker J, Lima JAC, Arbab-Zadeh A. Predictors of inaccurate coronary arterial stenosis assessment by CT angiography. JACC Cardiovasc Imaging 2013; 6:963-72. [PMID: 23932641 PMCID: PMC4162406 DOI: 10.1016/j.jcmg.2013.02.011] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Revised: 01/16/2013] [Accepted: 02/21/2013] [Indexed: 11/29/2022]
Abstract
OBJECTIVES This study sought to investigate the clinical and imaging characteristics associated with diagnostic inaccuracy of computed tomography angiography (CTA) for detecting obstructive coronary artery disease (CAD) defined by quantitative coronary angiography (QCA). BACKGROUND Although diagnostic performance metrics of CTA have been reported, there are sparse data on predictors of diagnostic inaccuracy by CTA. METHODS The clinical characteristics of 291 patients (mean age: 59 ± 10 years; female: 25.8%) enrolled in the multicenter CorE-64 (Coronary Artery Evaluation Using 64-Row Multi-detector Computed Tomography Angiography) study were examined. Pre-defined CTA segment-level characteristics of all true-positive (N = 237), false-positive (N = 115), false-negative (FN) (N = 159), and a random subset of true-negative segments (N = 511) for ≥50% stenosis with QCA as the reference standard were blindly abstracted in a central core laboratory. Factors independently associated with corresponding levels of CTA diagnostic inaccuracies on a patient level and coronary artery segment level were determined using multivariable logistic regression models and generalized estimating equations, respectively. RESULTS An Agatston calcium score of ≥1 per patient (odds ratio [OR]: 5.2; 95% confidence interval [CI]: 1.1 to 24.6) and the presence of within-segment calcification (OR: 10.2; 95% CI: 5.2 to 19.8) predicted false-positive diagnoses. Conversely, absence of within-segment calcification was an independent predictor of an FN diagnosis (OR: 2.0; 95% CI: 1.2 to 3.5). Prior percutaneous revascularization was independently associated with patient-level misdiagnosis of obstructive CAD (OR: 4.2; 95% CI: 1.6 to 11.2). Specific segment characteristics on CTA, notably segment tortuosity (OR: 3.5; 95% CI: 2.4 to 5.1), smaller luminal caliber (OR: 0.48; 95% CI: 0.36 to 0.63 per 1-mm increment), and juxta-arterial vein conspicuity (OR: 2.1; 95% CI: 1.4 to 3.2), were independently associated with segment-level misdiagnoses. Attaining greater intraluminal contrast enhancement independently lowered the risk of an FN diagnosis (OR: 0.96; 95% CI: 0.94 to 0.99 per 10-Hounsfield unit increment). CONCLUSIONS We identified clinical and readily discernible imaging characteristics on CTA predicting inaccurate CTA diagnosis of obstructive CAD defined by QCA. Knowledge and appropriate considerations of these features may improve the diagnostic accuracy in clinical CTA interpretation. (Diagnostic Accuracy of Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors [CORE-64]; NCT00738218).
Collapse
|
Multicenter Study |
12 |
58 |
20
|
Krishna SG, Rao BB, Ugbarugba E, Shah ZK, Blaszczak A, Hinton A, Conwell DL, Hart PA. Diagnostic performance of endoscopic ultrasound for detection of pancreatic malignancy following an indeterminate multidetector CT scan: a systemic review and meta-analysis. Surg Endosc 2017; 31:4558-4567. [PMID: 28378082 DOI: 10.1007/s00464-017-5516-y] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2016] [Accepted: 03/14/2017] [Indexed: 11/25/2022]
Abstract
BACKGROUND Pancreatic ductal adenocarcinoma (PDAC) has a dismal prognosis in part due to delayed diagnosis. Even with advances in cross-sectional imaging, small pancreatic malignancies can be missed. We sought to determine the performance of endoscopic ultrasound (EUS) in those without an obvious mass on multi-detector CT scan (MDCT), but with clinical suspicion for pancreatic malignancy. METHODS Multiple databases were systematically searched to identify studies that assessed the diagnostic performance of EUS after negative or inconclusive pancreatic protocol MDCT for detection of pancreatic malignancy when clinically suspected. A total of four studies met the inclusion criteria. The point estimates in each study were compared to the summary pooled estimates of sensitivity and specificity with the aid of forest plots. Funnel plots and Egger's test were employed to evaluate possible publication bias. RESULTS EUS-guided fine needle aspiration was performed in all studies. EUS was performed in 206 subjects with a clinical suspicion of a pancreatic mass but with an indeterminate MDCT. A pancreatic mass (mean size 21 ± 1.2 mm) was identified in 70% (n = 144) of the subjects, and 42.2% (n = 87) were diagnosed with PDAC. The pooled estimates of EUS for diagnosing pancreatic malignancy in the setting of an indeterminate MDCT were a sensitivity of 85% (95% CI 69-94%), specificity of 58% (95% CI 40-74%), positive predictive value of 77% (69-84%), negative predictive value of 66% (95% CI 53-77%), and an accuracy of 75% (95% CI 67-82). The summary area under the ROC curve was 0.80 (95% CI 0.52-0.89). The funnel plots and Egger's test did not show a significant publication bias. CONCLUSIONS The yield of EUS is comparatively higher for the diagnosis of a pancreatic malignancy in patients with suspected cancer, but a non-diagnostic MDCT. Importantly, the majority of the lesions missed on CT represent PDAC, in which early diagnosis is essential.
Collapse
|
Meta-Analysis |
8 |
57 |
21
|
Frauenfelder T, Winklehner A, Nguyen TDL, Dobrota R, Baumueller S, Maurer B, Distler O. Screening for interstitial lung disease in systemic sclerosis: performance of high-resolution CT with limited number of slices: a prospective study. Ann Rheum Dis 2014; 73:2069-73. [PMID: 25269829 DOI: 10.1136/annrheumdis-2014-205637] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
OBJECTIVES Early diagnosis of interstitial lung disease (ILD), currently the main cause of death in systemic sclerosis (SSc), is needed. The gold standard is high-resolution CT (HRCT) of the chest, but regular screening faces the risk of increased radiation exposure. We performed a prospective validation of a dedicated, 9-slice HRCT protocol with reduced radiation dose for the detection of ILD in patients with SSc. METHODS We analysed 170/205 consecutive patients with SSc. Whole-chest HRCT, serving as standard of reference, and the reduced HRCT with nine slices allocated according to a basal-apical gradient were obtained. ILD presence, extent (> or <20%) and diagnostic confidence were assessed. The reduced HRCT was independently analysed by two blinded radiologists, who also evaluated image quality. Radiation dose parameters were calculated. RESULTS Standard chest HRCT showed ILD in 77/170 patients. With the reduced HRCT, 68/77 cases with ILD were identified (sensitivity 88.3%, both readers). The accuracy (91.8%, reader 1; 94.7%, reader 2), diagnostic confidence (98.8%, reader 1; 95.3%, reader 2) and image quality rates were high. Minimal ILD was correctly quantified in 73.1% (reader 1)/71.2% (reader 2) and extensive ILD in 88% (reader 1)/100% (reader 2). Importantly, the reduced HRCT had a significantly lower radiation dose. The mean dose length product (effective dose) was only 5.66±4.46 mGycm (0.08±0.06 mSv) compared with the standard protocol dose of 149.00±95.90 mGycm (2.09±1.34 mSv). CONCLUSIONS The above-described reduced chest HRCT protocol reliably detects even mild SSc-ILD in clinical practice, with the advantage of a much lower radiation dose compared with standard whole-chest HRCT.
Collapse
|
|
11 |
57 |
22
|
Belousova E, Karmazanovsky G, Kriger A, Kalinin D, Mannelli L, Glotov A, Karelskaya N, Paklina O, Kaldarov A. Contrast-enhanced MDCT in patients with pancreatic neuroendocrine tumours: correlation with histological findings and diagnostic performance in differentiation between tumour grades. Clin Radiol 2017; 72:150-158. [PMID: 27890421 PMCID: PMC5552195 DOI: 10.1016/j.crad.2016.10.021] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 10/16/2016] [Accepted: 10/26/2016] [Indexed: 12/19/2022]
Abstract
AIM To identify the multidetector computed tomography (MDCT) features of pancreatic neuroendocrine tumours (pNETs), which correlate with tumour histology and enable preoperative grading. MATERIALS AND METHODS Thirty-nine patients with histologically confirmed pNET who underwent preoperative contrast-enhanced MDCT were included in this study. Nineteen tumours were classified as Grade 1 (G1) and 20 as Grade 2 (G2). Histopathology slides were reviewed to assess the intratumoural microvascular density (MVD) and the amount of tumour stroma. Computed tomography (CT) image analysis included tumour size, margin delineation, calcifications, homogeneity, contrast enhancement (CE) pattern, tumour absolute and relative enhancement, presence of cystic changes, pancreatic duct dilatation, regional and distant metastases. The diagnostic ability to predict tumour grade was measured for each MDCT finding and their combinations. RESULTS The mean arterial enhancement ratio had a mean±standard deviation of 1.53±0.45 in G1 and 1.01±0.33 in G2 pNETs (p=0.0003) and correlated with intratumoural microvascular density (MVD; r=0.55, p=0.0002). Tissue stroma percentage did not correlate with imaging findings. Late CE of the tumour (the peak attenuation observed in the venous phase) was significantly associated with G2. Tumour size >20 mm, arterial enhancement ratio <1.1, and late CE showed 74.4%, 79.5%, and 74.4% accuracy, respectively, in diagnosing G2 tumours, while the accuracy of at least two of these criteria used in combination was 82%. Based on these results, a diagnostic algorithm was proposed, which showed high interobserver agreement (k=0.82) in the prediction of tumour grade. CONCLUSION Contrast-enhanced MDCT features correlate with histological findings and enable the differentiation between G1 and G2 pNETs during preoperative examination.
Collapse
|
Comparative Study |
8 |
55 |
23
|
Binda GA, Cuomo R, Laghi A, Nascimbeni R, Serventi A, Bellini D, Gervaz P, Annibale B. Practice parameters for the treatment of colonic diverticular disease: Italian Society of Colon and Rectal Surgery (SICCR) guidelines. Tech Coloproctol 2015; 19:615-626. [PMID: 26377584 DOI: 10.1007/s10151-015-1370-x] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Accepted: 05/15/2015] [Indexed: 02/05/2023]
Abstract
The mission of the Italian Society of Colorectal Surgery (SICCR) is to optimize patient care. Providing evidence-based practice guidelines is therefore of key importance. About the present report it concernes the SICCR practice guidelines for the diagnosis and treatment of diverticular disease of the colon. The guidelines are not intended to define the sole standard of care but to provide evidence-based recommendations regarding the available therapeutic options.
Collapse
|
Practice Guideline |
10 |
55 |
24
|
Therkelsen KE, Pedley A, Hoffmann U, Fox CS, Murabito JM. Intramuscular fat and physical performance at the Framingham Heart Study. AGE (DORDRECHT, NETHERLANDS) 2016; 38:31. [PMID: 26899132 PMCID: PMC5005897 DOI: 10.1007/s11357-016-9893-2] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Accepted: 02/15/2016] [Indexed: 05/14/2023]
Abstract
Intramuscular fat may mediate associations between obesity and physical disability. We examined the associations between muscle attenuation, a proxy for intramuscular fat, and physical function. Paraspinous muscle computed tomography attenuation was obtained on a Framingham Heart Study subgroup (n = 1152, 56 % women, mean age 66 years). Regressions modeled cross-sectional associations between muscle attenuation and mobility disability, grip strength, and walking speed with standard covariates; models additionally adjusted for body mass index (BMI) and visceral adipose tissue (VAT). Separate models investigated associations between VAT and subcutaneous adipose tissue (SAT) and physical function. Per 1 standard deviation decrement in muscle attenuation (i.e., more muscle fat), we observed 1.29 (95 % CI = 1.11, 1.50; p = 0.0009) increased odds of walking speed ≤1 m/s in women and men. This persisted after separate BMI and VAT adjustments (p < 0.02). In men, there was a 1.29 kg (95 % CI = 0.57, 2.01; p = 0.0005) decrement in grip strength, which persisted after BMI and VAT adjustments (p ≤ 0.0004). For VAT and SAT, similar associations were not observed. Intramuscular fat is associated with increased odds of walking speed ≤1 m/s in both sexes and lower grip strength in men. There were no similar associations for VAT and SAT, highlighting the specificity of intramuscular fat in association with physical function.
Collapse
|
Research Support, N.I.H., Extramural |
9 |
53 |
25
|
Pickhardt PJ, Kitchin D, Lubner MG, Ganeshan DM, Bhalla S, Covey AM. Primary hepatic angiosarcoma: multi-institutional comprehensive cancer centre review of multiphasic CT and MR imaging in 35 patients. Eur Radiol 2015; 25:315-322. [PMID: 25278246 DOI: 10.1007/s00330-014-3442-0] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2014] [Revised: 08/10/2014] [Accepted: 09/12/2014] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To assess the imaging features of primary hepatic angiosarcoma on multiphasic CT and MR. METHODS Multi-institutional review identified 35 adults (mean age, 57.1 years; 22M/13F) with pathologically proven hepatic angiosarcoma and pretreatment multiphasic CT (n = 33) and/or MR (n = 7). RESULTS Multifocal hepatic involvement was seen in all 35 cases, with at least 10 lesions in 74.3% (26/35). Mean size of the dominant mass was 8.9 ± 4.7 cm (range, 2.6-20 cm). Individual nodules were typically circumscribed. Arterial-phase foci of hypervascular enhancement without washout were seen in 89.7% (26/29). Heterogeneously expanding foci of enhancement generally followed blood pool in 88.6% (31/35). Progressive centripetal (n = 16) or diffuse "flash-fill" (n = 4) enhancement pattern resembling cavernous haemangiomas predominated in 20 cases, whereas a "reverse haemangioma" centrifugal pattern predominated in 11 cases. Rapid interval growth was seen in 24 (96.0%) of 25 cases with serial imaging. Vascular invasion was not seen in any case. Underlying cirrhotic morphology was seen in 42.3% (15/35). CONCLUSION Primary hepatic angiosarcomas typically manifest as aggressive multifocal tumors containing small heterogeneous hypervascular foci that progressively expand and follow blood pool. The appearance can mimic cavernous haemangiomas, but distinction is generally possible. In the setting of cirrhosis, lack of tumour washout and vascular invasion argue against multifocal hepatocellular carcinoma. KEY POINTS • Hepatic angiosarcoma manifests on CT and MR as rapidly progressive multifocal tumours • Multiphasic imaging demonstrates hypervascular foci that progressively expand and follow blood pool • Enhancement pattern can resemble cavernous haemangiomas or show a "reverse" centrifugal pattern • Lack of tumour washout of hypervascular lesions argues against multifocal hepatocellular carcinoma • Careful assessment of the cross-sectional imaging findings may suggest the diagnosis.
Collapse
|
Evaluation Study |
10 |
52 |