1
|
|
|
56 |
240 |
2
|
Brown CM, Dalal RB, Hebert B, Digman MA, Horwitz AR, Gratton E. Raster image correlation spectroscopy (RICS) for measuring fast protein dynamics and concentrations with a commercial laser scanning confocal microscope. J Microsc 2008; 229:78-91. [PMID: 18173647 PMCID: PMC3690660 DOI: 10.1111/j.1365-2818.2007.01871.x] [Citation(s) in RCA: 136] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Raster image correlation spectroscopy (RICS) is a new and novel technique for measuring molecular dynamics and concentrations from fluorescence confocal images. The RICS technique extracts information about molecular dynamics and concentrations from images of living cells taken on commercial confocal systems. Here we develop guidelines for performing the RICS analysis on an analogue commercial laser scanning confocal microscope. Guidelines for typical instrument settings, image acquisition settings and analogue detector characterization are presented. Using appropriate instrument/acquisition parameters, diffusion coefficients and concentrations can be determined, even for highly dynamic dye molecules in solution. Standard curves presented herein demonstrate the ability to detect protein concentrations as low as approximately 2 nM. Additionally, cellular measurements give accurate values for the diffusion of paxillin-enhanced-green fluorescent protein (EGFP), an adhesion adaptor molecule, in the cytosol of the cell and also show slower paxillin dynamics near adhesions where paxillin interacts with immobile adhesion components. Methods are presented to account for bright immobile structures within the cell that dominate spatial correlation functions; allowing the extraction of fast protein dynamics within and near these structures. A running average algorithm is also presented to address slow cellular movement or movement of cellular features such as adhesions. Finally, methods to determine protein concentration in the presence of immobile structures within the cell are presented. A table is presented giving guidelines for instrument and imaging setting when performing RICS on the Olympus FV300 confocal and these guidelines are a starting point for performing the analysis on other commercial confocal systems.
Collapse
|
Research Support, N.I.H., Extramural |
17 |
136 |
3
|
van Ree R, Chapman MD, Ferreira F, Vieths S, Bryan D, Cromwell O, Villalba M, Durham SR, Becker WM, Aalbers M, André C, Barber D, Cistero Bahima A, Custovic A, Didierlaurent A, Dolman C, Dorpema JW, Di Felice G, Eberhardt F, Fernandez Caldas E, Fernandez Rivas M, Fiebig H, Focke M, Fötisch K, Gadermaier G, Das RG, Gonzalez Mancebo E, Himly M, Kinaciyan T, Knulst AC, Kroon AM, Lepp U, Marco FM, Mari A, Moingeon P, Monsalve R, Neubauer A, Notten S, Ooievaar-de Heer P, Pauli G, Pini C, Purohit A, Quiralte J, Rak S, Raulf-Heimsoth M, San Miguel Moncin MM, Simpson B, Tsay A, Vailes L, Wallner M, Weber B. The CREATE project: development of certified reference materials for allergenic products and validation of methods for their quantification. Allergy 2008; 63:310-26. [PMID: 18269676 DOI: 10.1111/j.1398-9995.2007.01612.x] [Citation(s) in RCA: 131] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Allergen extracts have been used for diagnosis and treatment of allergy for around 100 years. During the second half of 20th century, the notion increasingly gained foothold that accurate standardization of such extracts is of great importance for improvement of their quality. As a consequence, manufacturers have implemented extensive protocols for standardization and quality control. These protocols have overall IgE-binding potencies as their focus. Unfortunately, each company is using their own in-house reference materials and their own unique units to express potencies. This does not facilitate comparison of different products. During the last decades, most major allergens of relevant allergen sources have been identified and it has been established that effective immunotherapy requires certain minimum quantities of these allergens to be present in the administered maintenance dose. Therefore, the idea developed to introduce major allergens measurements into standardization protocols. Such protocols based on mass units of major allergen, quantify the active ingredients of the treatment and will at the same time allow comparison of competitor products. In 2001, an EU funded project, the CREATE project, was started to support introduction of major allergen based standardization. The aim of the project was to evaluate the use of recombinant allergens as reference materials and of ELISA assays for major allergen measurements. This paper gives an overview of the achievements of the CREATE project.
Collapse
|
Review |
17 |
131 |
4
|
Wagner MS, McArthur SL, Shen M, Horbett TA, Castner DG. Limits of detection for time of flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS): detection of low amounts of adsorbed protein. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2003; 13:407-28. [PMID: 12160301 DOI: 10.1163/156856202320253938] [Citation(s) in RCA: 106] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Characterization of biomaterial surfaces requires analytical techniques that are capable of detecting a wide concentration range of adsorbed protein. This range includes detection of low amounts of adsorbed protein (<10 ng/cm2) that may be present on non-fouling biomaterials. X-ray Photoelectron Spectroscopy (XPS) and Time of Flight Secondary Ion Mass Spectrometry (ToF-SIMS) are surface sensitive techniques capable of detecting adsorbed proteins. We have investigated the lower limits of detection of both XPS and ToF-SIMS on four model substrates each presenting unique challenges for analysis by XPS and ToF-SIMS: mica, poly(tetrafluoroethylene), allyl amine plasma polymer and heptyl amine plasma polymer. The detection limit for XPS ranged from 10 ng/cm2 of fibrinogen (on mica) to 200 ng/cm2 (on allyl amine plasma polymers). The detection limit for ToF-SIMS ranged from 0.1 ng/cm2 of fibrinogen to 100 ng/cm2, depending on the substrate and data analysis. Optimal conditions provided detection limits between 0.1 ng/cm2 and 15 ng/cm2 on all of the substrates used in this study. While both techniques were shown to be effective in detecting protein, the sensitivity of both XPS and ToF-SIMS was shown to be dependent on substrate surface chemistry and the organization of the adsorbed protein film. This study specifically highlights the applicability of ToF-SIMS in the characterization of low level protein adsorption.
Collapse
|
Comparative Study |
22 |
106 |
5
|
Jacquamet L, Aberdam D, Adrait A, Hazemann JL, Latour JM, Michaud-Soret I. X-ray absorption spectroscopy of a new zinc site in the fur protein from Escherichia coli. Biochemistry 1998; 37:2564-71. [PMID: 9485406 DOI: 10.1021/bi9721344] [Citation(s) in RCA: 89] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The zinc K-edge X-ray absorption spectra of the Fur (ferric uptake regulation) protein isolated from Escherichia coli have been analyzed in frozen solution to determine details of the zinc coordination. The spectra of apoFur and of the cobalt-substituted protein have been analyzed and compared in order to see the influence of the cobalt incorporation on the geometry of the zinc site. EXAFS analysis gave for both samples (apoFur and CoFur) a tetrahedral environment for the zinc atom with two sulfur donor ligands at a distance of 2.3 A from the zinc and two N/O donor ligands at 2.0 A. The two sulfur donor ligands are probably two of the four cysteines present in each Fur monomer and could be Cys92 and Cys95, which are known from mutagenesis studies to be essential for Fur activity [Coy, M., Doyle, C., Besser, J., and Neilands, J. B. (1994) BioMetals 7, 292-298]. The distances obtained from our fits were always too short to be compatible with penta or hexa coordination. The typical pattern observed for the Fourier transform of the EXAFS oscillations suggests the presence of at least one imidazole ligand. The XANES of these two forms of the protein are similar but significantly different. This suggests a change of the conformation of the zinc site upon cobalt incorporation. The present study provides the first unambiguous evidence for the presence of a structural zinc site in the Fur protein from Escherichia coli.
Collapse
|
Comparative Study |
27 |
89 |
6
|
Redberg RF, Vogel RA, Criqui MH, Herrington DM, Lima JAC, Roman MJ. 34th Bethesda Conference: Task force #3--What is the spectrum of current and emerging techniques for the noninvasive measurement of atherosclerosis? J Am Coll Cardiol 2003; 41:1886-98. [PMID: 12798555 DOI: 10.1016/s0735-1097(03)00360-7] [Citation(s) in RCA: 88] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
Review |
22 |
88 |
7
|
Iamele L, Fiocchi R, Vernocchi A. Evaluation of an automated spectrophotometric assay for reactive oxygen metabolites in serum. Clin Chem Lab Med 2003; 40:673-6. [PMID: 12241012 DOI: 10.1515/cclm.2002.115] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The in vivo assessment of free radicals concentration is hampered by their instability and extremely short half-life. The Diacron Reactive Oxygen Metabolites (D-ROM) test is a recently introduced method to evaluate the peroxidation of organic compounds. Since the manual performance of the test provides excessive analytical imprecision, the aim of this study was to evaluate the automation of this test. Within- and between-run imprecision and interference were assessed according to the guidelines proposed by the NCCLS. The reactive oxygen metabolites' (ROM) stability was evaluated in different physical conditions. For within-run and between-run imprecision the coefficients of variation were consistently lower than 5%. The maximum allowable concentration was 28.2 mmol/l, 0.068 mmol/l and 171 mmol/l for triglycerides, haemoglobin and bilirubin, respectively. Serum storage at -20 degrees C provided adequate ROM stability for up to 3 months, whereas storage at 4 degrees C yielded non-reproducible results. In conclusion, our data provide evidence that the D-ROM assay has both an acceptable stability and an adequate imprecision. The automated assay may be regarded as a fast and reproducible method for the quantitative evaluation of oxidative stress. Since it is easily performed, the method is suitable for routine in clinical laboratories and may provide an accurate estimation of oxidative stress in vivo.
Collapse
|
Journal Article |
22 |
76 |
8
|
McCabe BP, Speidel MA, Pike TL, Van Lysel MS. Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner. Med Phys 2011; 38:1919-30. [PMID: 21626925 PMCID: PMC3078021 DOI: 10.1118/1.3560422] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2010] [Revised: 02/04/2011] [Accepted: 02/06/2011] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In this study, newly formulated XR-RV3 GafChromic film was calibrated with National Institute of Standards and Technology (NIST) traceability for measurement of patient skin dose during fluoroscopically guided interventional procedures. METHODS The film was calibrated free-in-air to air kerma levels between 15 and 1100 cGy using four moderately filtered x-ray beam qualities (60, 80, 100, and 120 kVp). The calibration films were scanned with a commercial flatbed document scanner. Film reflective density-to-air kerma calibration curves were constructed for each beam quality, with both the orange and white sides facing the x-ray source. A method to correct for nonuniformity in scanner response (up to 25% depending on position) was developed to enable dose measurement with large films. The response of XR-RV3 film under patient backscattering conditions was examined using on-phantom film exposures and Monte Carlo simulations. RESULTS The response of XR-RV3 film to a given air kerma depended on kVp and film orientation. For a 200 cGy air kerma exposure with the orange side of the film facing the source, the film response increased by 20% from 60 to 120 kVp. At 500 cGy, the increase was 12%. When 500 cGy exposures were performed with the white side facing the x-ray source, the film response increased by 4.0% (60 kVp) to 9.9% (120 kVp) compared to the orange-facing orientation. On-phantom film measurements and Monte Carlo simulations show that using a NIST-traceable free-in-air calibration curve to determine air kerma in the presence of backscatter results in an error from 2% up to 8% depending on beam quality. The combined uncertainty in the air kerma measurement from the calibration curves and scanner nonuniformity correction was +/- 7.1% (95% C.I.). The film showed notable stability. Calibrations of film and scanner separated by 1 yr differed by 1.0%. CONCLUSIONS XR-RV3 radiochromic film response to a given air kerma shows dependence on beam quality and film orientation. The presence of backscatter slightly modifies the x-ray energy spectrum; however, the increase in film response can be attributed primarily to the increase in total photon fluence at the sensitive layer. Film calibration curves created under free-in-air conditions may be used to measure dose from fluoroscopic quality x-ray beams, including patient backscatter with an error less than the uncertainty of the calibration in most cases.
Collapse
|
Research Support, N.I.H., Extramural |
14 |
70 |
9
|
Urry DW, Hinners TA, Masotti L. Calculation of distorted circular dichroism curves for poly-L-glutamic acid suspensions. Arch Biochem Biophys 1970; 137:214-21. [PMID: 5435058 DOI: 10.1016/0003-9861(70)90428-5] [Citation(s) in RCA: 65] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
|
55 |
65 |
10
|
Senesi GS, Dell'Aglio M, Gaudiuso R, De Giacomo A, Zaccone C, De Pascale O, Miano TM, Capitelli M. Heavy metal concentrations in soils as determined by laser-induced breakdown spectroscopy (LIBS), with special emphasis on chromium. ENVIRONMENTAL RESEARCH 2009; 109:413-20. [PMID: 19272593 DOI: 10.1016/j.envres.2009.02.005] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2008] [Revised: 12/12/2008] [Accepted: 02/02/2009] [Indexed: 05/05/2023]
Abstract
Soil is unanimously considered as one of the most important sink of heavy metals released by human activities. Heavy metal analysis of natural and polluted soils is generally conducted by the use of atomic absorption spectroscopy (AAS) or inductively coupled plasma optical emission spectroscopy (ICP-OES) on adequately obtained soil extracts. Although in recent years the emergent technique of laser-induced breakdown spectroscopy (LIBS) has been applied widely and with increasing success for the qualitative and quantitative analyses of a number of heavy metals in soil matrices with relevant simplification of the conventional methodologies, the technique still requires further confirmation before it can be applied fully successfully in soil analyses. The main objective of this work was to demonstrate that new developments in LIBS technique are able to provide reliable qualitative and quantitative analytical evaluation of several heavy metals in soils, with special focus on the element chromium (Cr), and with reference to the concentrations measured by conventional ICP spectroscopy. The preliminary qualitative LIBS analysis of five soil samples and one sewage sludge sample has allowed the detection of a number of elements including Al, Ca, Cr, Cu, Fe, Mg, Mn, Pb, Si, Ti, V and Zn. Of these, a quantitative analysis was also possible for the elements Cr, Cu, Pb, V and Zn based on the obtained linearity of the calibration curves constructed for each heavy metal, i.e., the proportionality between the intensity of the LIBS emission peaks and the concentration of each heavy metal in the sample measured by ICP. In particular, a triplet of emission lines for Cr could be used for its quantitative measurement. The consistency of experiments made on various samples was supported by the same characteristics of the laser-induced plasma (LIP), i.e., the typical linear distribution confirming the existence of local thermodynamic equilibrium (LTE) condition, and similar excitation temperatures and comparable electron number density measured for all samples. An index of the anthropogenic contribution of Cr in polluted soils was calculated in comparison to a non-polluted reference soil. Thus, the intensity ratios of the emission lines of heavy metal can be used to detect in few minutes the polluted areas for which a more detailed sampling and analysis can be useful.
Collapse
|
|
16 |
63 |
11
|
Locuson CW, Hutzler JM, Tracy TS. Visible spectra of type II cytochrome P450-drug complexes: evidence that "incomplete" heme coordination is common. Drug Metab Dispos 2007; 35:614-22. [PMID: 17251307 DOI: 10.1124/dmd.106.012609] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The visible spectrum of a ligand-bound cytochrome P450 is often used to determine the nature of the interaction between the ligand and the P450. One particularly characteristic form of spectra arises from the coordination of nitrogen-containing ligands to the P450 heme iron. These type II ligands tend to be inhibitors because they stabilize the low reduction potential P450 and prevent oxygen binding to the heme. Yet, several type II ligands containing aniline, imidazole, and triazole moieties are also known to be substrates of P450, although P450 binding spectra are not often scrutinized to make this distinction. Therefore, the three nitrogenous ligands aniline, imidazole, and triazole were used as binding spectra standards with purified human CYP3A4 and CYP2C9, because their small size should not present any steric limitations in their accessing the heme prosthetic group. Next, the spectra of P450 with drugs containing the three nitrogenous groups were collected for comparison. The absolute spectra demonstrated that the red-shift of the low-spin Soret band is mostly dependent on the electronic properties of the nitrogen ligand since they tended to match their respective standards, aniline, imidazole, and triazole. On the other hand, difference spectra seemed to be more sensitive to the steric properties of the ligand because they facilitated comparison of the spectral amplitudes achieved with the drugs versus those with the standard nitrogen ligands. Therefore, difference spectra may help reveal "weak" coordination to the heme that results from suboptimal orientation or ligand binding to more remote locations within the P450 active sites.
Collapse
|
Comparative Study |
18 |
61 |
12
|
Siira SM, Ojala TH, Vahlberg TJ, Jalonen JO, Välimäki IA, Rosén KG, Ekholm EM. Marked fetal acidosis and specific changes in power spectrum analysis of fetal heart rate variability recorded during the last hour of labour. BJOG 2005; 112:418-23. [PMID: 15777438 DOI: 10.1111/j.1471-0528.2004.00454.x] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To assess whether intrapartum acidosis affects specific components of fetal heart rate variability. DESIGN Prospective clinical study. SETTING Twelve Nordic delivery units. SUBJECTS Fetal heart rate variability was studied in 334 fetuses divided into two groups according to cord pH value: the acidotic group (cord arterial pH < 7.05 at birth, n= 15) and the control group (cord arterial pH > or =7.05 at birth, n= 319). METHODS In spectral analysis of fetal heart rate variability, frequencies were integrated over the total frequency band (0.04-1.0 Hz), low-frequency band (0.04-0.15 Hz) and high-frequency band (0.15-1.0 Hz). We also calculated the low-to-high frequency ratio. MAIN OUTCOME MEASURES The spectral bands of fetal heart rate variability were compared between the acidotic and control fetuses. RESULTS We found that during the last hour of monitoring, baseline fetal heart rate gradually decreased, whereas total, low-frequency and high-frequency fetal heart rate variability initially increased but then, near the delivery, decreased in the acidotic fetuses when compared with the controls. Low-to-high frequency ratio was greater in the acidotic group during the whole study period (P= 0.002). Cord artery pH was inversely associated with total fetal heart rate variability (P < 0.001), low-frequency fetal heart rate variability (P < 0.001) and low-to-high frequency ratio (P= 0.004). CONCLUSIONS Marked fetal acidosis was associated with frequency-specific changes in fetal heart rate variability as reflecting the compensation ability of autonomic nervous activation during the last hour of labour.
Collapse
|
|
20 |
57 |
13
|
Beda N, Nedospasov A. A spectrophotometric assay for nitrate in an excess of nitrite. Nitric Oxide 2005; 13:93-7. [PMID: 16006157 DOI: 10.1016/j.niox.2005.05.002] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2004] [Revised: 04/29/2005] [Accepted: 05/07/2005] [Indexed: 11/25/2022]
Abstract
Miranda et al. have developed a method for simultaneous evaluation of nitrate and nitrite concentrations using reduction of nitrate by vanadium(III) combined with detection by the acidic Griess reaction [K.M. Miranda, M.G. Espey, D.A. Wink, A rapid, simple spectrophotometric method for simultaneous detection of nitrate and nitrite, Nitric Oxide 5 (2001) 62-71]. The sensitivity of the nitrate assay decline if the mixture analyzed contains a large excess of nitrite relative to nitrate, for instance, in the case of oxidation products of nitric oxide (NO) in aerated solutions, or in sweat. By this reason nitrite should be removed before the nitrate assay, if [NO2-]>>[NO3-]. Here we lay out an improved method allowing the above limitation to be erased, using sulfamic acid for nitrite removal. We also describe some modifications that enhance the reproducibility of the assay.
Collapse
|
Research Support, Non-U.S. Gov't |
20 |
54 |
14
|
Abstract
Fibrin clot structure studies are often performed using optical methods. For example, the clot's fiber structure can be assessed by measuring light scattering as a function of wavelength. From these measurements, one can calculate the mass/length ratio (mu), a relative measure of fibrin thickness. Fiber thickness has important functional correlates in terms of clot stability and resistance to fibrinolysis. Typically, measurements to calculate mass/length ratios are carried out on high-end spectrophotometers. However, limitations of this instrument include the large sample volume required and the inability to read multiple samples at one time. To circumvent these limitations, a plate-reading spectrophotometer is more commonly used to monitor clot formation; increases in absorbance indicate clot formation, while decreases indicate clot lysis. However, it is unclear whether plate-reading spectrophotometers can be used to quantitatively evaluate fibrin fiber structure. In the current study, we compared spectrophotometric analysis of fibrin gels on single-sample and plate-reading spectrophotometers. Results show that a plate-reading spectrophotometer does not give accurate measurements of the fiber mass/length ratio. However, the plate-reading spectrophotometer can provide a qualitative measure of fiber structure for both purified fibrinogen and plasma. We suggest that plate-reading spectrophotometers can provide a convenient, rapid, and inexpensive means of analyzing fibrin clot structure.
Collapse
|
Comparative Study |
23 |
54 |
15
|
Kim G, Kwak J, Choi J, Park K. Detection of nutrient elements and contamination by pesticides in spinach and rice samples using laser-induced breakdown spectroscopy (LIBS). JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2012; 60:718-724. [PMID: 22148630 DOI: 10.1021/jf203518f] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The laser-induced breakdown spectroscopy (LIBS) technique was applied to quantify nutrients (Mg, Ca, Na, and K) in spinach and rice and to discriminate pesticide-contaminated products in a rapid manner. Standard reference materials (spinach leaves and unpolished rice flour) were used to establish a relationship between LIBS intensity and the concentration of each element (Mg, Ca, Na, and K) (i.e., calibration line). The limits of detection (LODs) for Mg, Ca, Na, and K were found to be 29.63, 102.65, 36.36, and 44.46 mg/kg in spinach and 7.54, 1.76, 4.19, and 6.70 mg/kg in unpolished rice, respectively. Concentrations of those nutrient elements present in spinach and unpolished rice from a local market were determined by using the calibration lines and compared with those measured with ICP-OES, showing good agreement. The data also suggested that the LIBS technique with the chemometric method (PLS-DA) could be a great tool to distinguish pesticide-contaminated samples from pesticide-free samples in a rapid manner even though they have similar elemental compositions. Misclassification rates were found to be 0 and 2% for clean spinach and pesticide-contaminated spinach, respectively, by applying the PLS-DA model established from the training set of data to predict the classes of test samples.
Collapse
|
Evaluation Study |
13 |
52 |
16
|
Wang R, Wang Y. Fourier Transform Infrared Spectroscopy in Oral Cancer Diagnosis. Int J Mol Sci 2021; 22:1206. [PMID: 33530491 PMCID: PMC7865696 DOI: 10.3390/ijms22031206] [Citation(s) in RCA: 51] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/19/2021] [Accepted: 01/21/2021] [Indexed: 12/13/2022] Open
Abstract
Oral cancer is one of the most common cancers worldwide. Despite easy access to the oral cavity and significant advances in treatment, the morbidity and mortality rates for oral cancer patients are still very high, mainly due to late-stage diagnosis when treatment is less successful. Oral cancer has also been found to be the most expensive cancer to treat in the United States. Early diagnosis of oral cancer can significantly improve patient survival rate and reduce medical costs. There is an urgent unmet need for an accurate and sensitive molecular-based diagnostic tool for early oral cancer detection. Fourier transform infrared spectroscopy has gained increasing attention in cancer research due to its ability to elucidate qualitative and quantitative information of biochemical content and molecular-level structural changes in complex biological systems. The diagnosis of a disease is based on biochemical changes underlying the disease pathology rather than morphological changes of the tissue. It is a versatile method that can work with tissues, cells, or body fluids. In this review article, we aim to summarize the studies of infrared spectroscopy in oral cancer research and detection. It provides early evidence to support the potential application of infrared spectroscopy as a diagnostic tool for oral potentially malignant and malignant lesions. The challenges and opportunities in clinical translation are also discussed.
Collapse
|
Review |
4 |
51 |
17
|
Kirkby C, Sloboda R. Consequences of the spectral response of an a-Si EPID and implications for dosimetric calibration. Med Phys 2005; 32:2649-58. [PMID: 16193795 DOI: 10.1118/1.1984335] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
One of the attractive features of amorphous silicon electronic portal imaging devices (a-Si EPIDs) as dosimetric tools is that for open fields they are known to exhibit a generally linear relation between pixel value and incident energy fluence as measured by an ion chamber. It has also been established that a-Si EPIDs incorporating high atomic number phosphors such as Gd2O2S:Tb exhibit a disproportionately large response to low-energy (<1 MeV) photons. The present work examines the consequences of this hypersensitivity in a commercially available EPID, the Varian aS500, with respect to energy fluence calibration in a 6 MV radiotherapy beam. EPIDs may be deployed in situations where the spectrum of the incident beam is modified by passing through a compensator or through a patient or phantom. By examining the specific case of a beam hardened by passage through compensator material, we show that the discrepancy between open and attenuated beam calibration curves can be as high as 8%. A Monte Carlo study using a comprehensive model of the aS500 shows that this difference can be explained by spectral changes, and further suggests that it can be reduced by the addition of an external copper plate. We consider configurations with the plate placed directly on top of the EPID cassette and 15 cm above the cassette, supported by Styrofoam. In order to reduce the maximum discrepancy to <4%, it was found that a copper thickness of approximately 0.7 cm was required in the elevated configuration. Improvement was minimal with the copper in the contact configuration. Adding 0.7 cm of copper in the elevated configuration reduced the contrast-to-noise ratio by 19% and the modulation transfer for a given spatial frequency by 30%.
Collapse
|
|
20 |
46 |
18
|
Meyer P, Buffard E, Mertz L, Kennel C, Constantinesco A, Siffert P. Evaluation of the use of six diagnostic X-ray spectra computer codes. Br J Radiol 2004; 77:224-30. [PMID: 15020364 DOI: 10.1259/bjr/32409995] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
A knowledge of photon energy spectra emitted from X-ray tubes in radiology is crucial for many research domains in the medical field. Since spectrometry is difficult because of high photon fluence rates, a convenient solution is to use computational models. This paper describes the use of six computer codes based on semiempirical or empirical models. The use of the codes was assessed, notably by comparing theoretical half value layers and air kerma with measurements on five different X-ray tubes used in a research hospital. It was found that three out of the six computer codes give relative spectra very close to those produced by X-ray units equipped with constant potential generators: the mean difference between measured and modelled half value layer was less than 3% with a standard deviation of 3.6% whatever the tube and the applied voltage. Absolute output is less accurate: for four computer codes, the mean difference between the measured and modelled air kerma was between 18% and 36%, with a standard deviation of 9% whatever the tube (except for the single phase generator) and the applied voltage. One of the codes gives a good output and beam quality for X-ray units equipped with 100% ripple voltage generators. The use of computational codes as described in this paper provides a means of modelling relative diagnostic X-ray spectra, the usefulness of the tube output data depending on the accuracy required by the end user.
Collapse
|
Research Support, Non-U.S. Gov't |
21 |
43 |
19
|
Cookson P, Sutherland J, Cardigan R. A simple spectrophotometric method for the quantification of residual haemoglobin in platelet concentrates. Vox Sang 2005; 87:264-71. [PMID: 15585022 DOI: 10.1111/j.1423-0410.2004.00566.x] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND OBJECTIVES High levels of residual haemoglobin (Hb 0.1 g/l) are known to decrease the efficiency of pathogen-inactivation systems. We evaluated three separate methods to quantify Hb in platelet concentrates (PC). MATERIALS AND METHODS Nine PC prepared in platelet additive solution (PASIII) (median platelet yield of 283 x 10(9)/unit, range 46-353) were spiked to known Hb concentrations with whole blood and the samples were measured by using each of three methods: the 3,3',5,5'-tetramethylbenzidine (TMB) oxidation method (Sigma Diagnostics, 527-A); the Harboe spectrophotometric method; and the HemoCue plasma low-Hb photometer (PLHP). RESULTS The TMB and Harboe methods showed linear results compared to expected Hb (r2 > or = 0.981, P < 0.001) over the range tested (0.09-0.28 g/l) when the samples were haemolysed. The TMB method underestimated by an average of 6%, at and around 0.1 g/l Hb, compared to a 4% overestimation by the Harboe method and a threefold overestimation by the PLHP. The Harboe intra-assay coefficient of variation was < or = 1.85% across all concentrations, which contrasted with 30% at and around 0.1 g/l for the TMB method. CONCLUSIONS The Harboe spectrophotometric method is convenient, safe, accurate and reproducible, and outperforms the TMB and PLHP methods for quantification of residual Hb in PC.
Collapse
|
Journal Article |
20 |
39 |
20
|
Skeldon KD, McMillan LC, Wyse CA, Monk SD, Gibson G, Patterson C, France T, Longbottom C, Padgett MJ. Application of laser spectroscopy for measurement of exhaled ethane in patients with lung cancer. Respir Med 2005; 100:300-6. [PMID: 16002272 DOI: 10.1016/j.rmed.2005.05.006] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2004] [Accepted: 05/07/2005] [Indexed: 11/19/2022]
Abstract
There is increasing interest in ethane (C(2)H(6)) in exhaled breath as a non-invasive marker of oxidative stress (OS) and thereby a potential indicator of disease. However, the lack of real-time measurement techniques has limited progress in the field. Here we report on a novel Tunable Diode Laser Spectrometer (TDLS) applied to the analysis of exhaled ethane in patients with lung cancer. The patient group (n=52) comprised randomly selected patients presenting at a respiratory clinic. Of these, a sub-group (n=12) was subsequently diagnosed with lung cancer. An age-matched group (n=12) corresponding to the lung cancer group was taken from a larger control group of healthy adults (n=58). The concentration of ethane in a single exhaled breath sample collected from all subjects was later measured using the TDLS. This technique is capable of real-time analysis of samples with accuracy 0.1 parts per billion (ppb), over 10 times less than typical ambient levels in the northern hemisphere. After correcting for ambient background, ethane in the control group (26% smokers) ranged from 0 to 10.54 ppb (median of 1.9 ppb) while ethane in the lung cancer patients (42% smokers) ranged from 0 to 7.6 ppb (median of 0.7 ppb). Ethane among the non-lung cancer patients presenting for investigation of respiratory disease ranged from 0 to 25 ppb (median 1.45 ppb). We conclude that, while the TDLS proved effective for accurate and rapid sample analysis, there was no significant difference in exhaled ethane among any of the subject groups. Comments are made on the suitability of the technique for monitoring applications.
Collapse
|
Research Support, Non-U.S. Gov't |
20 |
38 |
21
|
Hughes SA, Huang R, Mahaffey A, Chelme-Ayala P, Klamerth N, Meshref MNA, Ibrahim MD, Brown C, Peru KM, Headley JV, Gamal El-Din M. Comparison of methods for determination of total oil sands-derived naphthenic acids in water samples. CHEMOSPHERE 2017; 187:376-384. [PMID: 28863291 DOI: 10.1016/j.chemosphere.2017.08.123] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 08/18/2017] [Accepted: 08/22/2017] [Indexed: 05/24/2023]
Abstract
There are several established methods for the determination of naphthenic acids (NAs) in waters associated with oil sands mining operations. Due to their highly complex nature, measured concentration and composition of NAs vary depending on the method used. This study compared different common sample preparation techniques, analytical instrument methods, and analytical standards to measure NAs in groundwater and process water samples collected from an active oil sands operation. In general, the high- and ultrahigh-resolution methods, namely high performance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS) and Orbitrap mass spectrometry (Orbitrap-MS), were within an order of magnitude of the Fourier transform infrared spectroscopy (FTIR) methods. The gas chromatography mass spectrometry (GC-MS) methods consistently had the highest NA concentrations and greatest standard error. Total NAs concentration was not statistically different between sample preparation of solid phase extraction and liquid-liquid extraction. Calibration standards influenced quantitation results. This work provided a comprehensive understanding of the inherent differences in the various techniques available to measure NAs and hence the potential differences in measured amounts of NAs in samples. Results from this study will contribute to the analytical method standardization for NA analysis in oil sands related water samples.
Collapse
|
|
8 |
35 |
22
|
Hosseini MS, Hosseini-Bandegharaei A, Raissi H, Belador F. Sorption of Cr(VI) by Amberlite XAD-7 resin impregnated with brilliant green and its determination by quercetin as a selective spectrophotometric reagent. JOURNAL OF HAZARDOUS MATERIALS 2009; 169:52-57. [PMID: 19380195 DOI: 10.1016/j.jhazmat.2009.03.058] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2009] [Revised: 03/12/2009] [Accepted: 03/12/2009] [Indexed: 05/27/2023]
Abstract
A new chelating polymeric sorbent as an extractant-impregnated resin (EIR) has been developed using brilliant green (BG) and Amberlite XAD-7 resin. The BG-impregnated resin showed superior binding affinity for Cr(VI) in the presence of many co-existing ions and no considerable interference was observed. The influence of various physicochemical parameters on the recovery of Cr(VI) were optimized by both static and dynamic methods. The Langmuir adsorption isotherm gave a satisfactory fit of the equilibrium data. The kinetic studies performed for Cr(VI) sorption revealed that <45 min was sufficient for reaching equilibrium metal ion sorption. A preconcentration factor of 100 was found for the column-mode extraction. The spectrophotometric determination of eluted Cr(VI) was carried out using quercetin as a selective reagent. The calibration graphs were linear in the range 5.0 x 10(-8) to 4.0 x 10(-7)M with a detection limit of 8 x 10(-9)M. The proposed method has been successfully employed for the analysis of natural water. The recoveries for the Cr(VI) amounts spiked to the samples were >93%, which confirmed accuracy of the measurements.
Collapse
|
Evaluation Study |
16 |
34 |
23
|
Philipson KD, Sauer K. Light-scattering effects on the circular dichroism of chloroplasts. Biochemistry 1973; 12:3454-8. [PMID: 4199892 DOI: 10.1021/bi00742a015] [Citation(s) in RCA: 34] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
|
52 |
34 |
24
|
Pena AM, Chen X, Pence IJ, Bornschlögl T, Jeong S, Grégoire S, Luengo GS, Hallegot P, Obeidy P, Feizpour A, Chan KF, Evans CL. Imaging and quantifying drug delivery in skin - Part 2: Fluorescence andvibrational spectroscopic imaging methods. Adv Drug Deliv Rev 2020; 153:147-168. [PMID: 32217069 PMCID: PMC7483684 DOI: 10.1016/j.addr.2020.03.003] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2019] [Revised: 03/10/2020] [Accepted: 03/18/2020] [Indexed: 01/31/2023]
Abstract
Understanding the delivery and diffusion of topically-applied drugs on human skin is of paramount importance in both pharmaceutical and cosmetics research. This information is critical in early stages of drug development and allows the identification of the most promising ingredients delivered at optimal concentrations to their target skin compartments. Different skin imaging methods, invasive and non-invasive, are available to characterize and quantify the spatiotemporal distribution of a drug within ex vivo and in vivo human skin. The first part of this review detailed invasive imaging methods (autoradiography, MALDI and SIMS). This second part reviews non-invasive imaging methods that can be applied in vivo: i) fluorescence (conventional, confocal, and multiphoton) and second harmonic generation microscopies and ii) vibrational spectroscopic imaging methods (infrared, confocal Raman, and coherent Raman scattering microscopies). Finally, a flow chart for the selection of imaging methods is presented to guide human skin ex vivo and in vivo drug delivery studies.
Collapse
|
Systematic Review |
5 |
33 |
25
|
Abstract
The EVA descriptor is derived from fundamental IR and Raman range molecular vibrational frequencies. EVA is sensitive to 3-D structure, but has an advantage over field-based 3-D QSAR methods inasmuch as it is invariant to both translation and rotation of the structures concerned and thus structural superposition is not required. The latter property and the demonstration of the effectiveness of the descriptor for QSAR means that EVA has been the subject of a great deal of interest from the modelling community. This review describes the derivation of the descriptor, details its main parameters and how to apply them, and provides an overview of the validation that has been done with the descriptor. A recent enhancement to the technique is described which involves the localised adjustment of variance in such a way that enhanced internal and external predictability may be obtained. Despite the statistical quality of EVA QSAR models, the main draw-back to the descriptor at present is the difficulty associated with back-tracking from a PLS model to an EVA pharmacophore. Brief comment is made on the use of the EVA descriptor for diversity studies and the similarity searching of chemical structure databases.
Collapse
|
Review |
25 |
31 |