Basch E, Becker C, Rogak LJ, Schrag D, Reeve BB, Spears P, Smith ML, Gounder MM, Mahoney MR, Schwartz GK, Bennett AV, Mendoza TR, Cleeland CS, Sloan JA, Bruner DW, Schwab G, Atkinson TM, Thanarajasingam G, Bertagnolli MM, Dueck AC. Composite grading algorithm for the National Cancer Institute's Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE).
Clin Trials 2021;
18:104-114. [PMID:
33258687 PMCID:
PMC7878323 DOI:
10.1177/1740774520975120]
[Citation(s) in RCA: 107] [Impact Index Per Article: 26.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND
The Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events is an item library designed for eliciting patient-reported adverse events in oncology. For each adverse event, up to three individual items are scored for frequency, severity, and interference with daily activities. To align the Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events with other standardized tools for adverse event assessment including the Common Terminology Criteria for Adverse Events, an algorithm for mapping individual items for any given adverse event to a single composite numerical grade was developed and tested.
METHODS
A five-step process was used: (1) All 179 possible Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events score combinations were presented to 20 clinical investigators to subjectively map combinations to single numerical grades ranging from 0 to 3. (2) Combinations with <75% agreement were presented to investigator committees at a National Clinical Trials Network cooperative group meeting to gain majority consensus via anonymous voting. (3) The resulting algorithm was refined via graphical and tabular approaches to assure directional consistency. (4) Validity, reliability, and sensitivity were assessed in a national study dataset. (5) Accuracy for delineating adverse events between study arms was measured in two Phase III clinical trials (NCT02066181 and NCT01522443).
RESULTS
In Step 1, 12/179 score combinations had <75% initial agreement. In Step 2, majority consensus was reached for all combinations. In Step 3, five grades were adjusted to assure directional consistency. In Steps 4 and 5, composite grades performed well and comparably to individual item scores on validity, reliability, sensitivity, and between-arm delineation.
CONCLUSION
A composite grading algorithm has been developed and yields single numerical grades for adverse events assessed via the Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events, and can be useful in analyses and reporting.