1
|
Kullman E, Frozanpor F, Söderlund C, Linder S, Sandström P, Lindhoff-Larsson A, Toth E, Lindell G, Jonas E, Freedman J, Ljungman M, Rudberg C, Ohlin B, Zacharias R, Leijonmarck CE, Teder K, Ringman A, Persson G, Gözen M, Eriksson O. Covered versus uncovered self-expandable nitinol stents in the palliative treatment of malignant distal biliary obstruction: results from a randomized, multicenter study. Gastrointest Endosc 2010; 72:915-23. [PMID: 21034892 DOI: 10.1016/j.gie.2010.07.036] [Citation(s) in RCA: 216] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2010] [Accepted: 07/24/2010] [Indexed: 02/07/2023] [Imported: 02/09/2025]
Abstract
BACKGROUND Covered biliary metal stents have been developed to prevent tumor ingrowth. Previous comparative studies are limited and often include few patients. OBJECTIVE To compare differences in stent patency, patient survival, and complication rates between covered and uncovered nitinol stents in patients with malignant biliary obstruction. DESIGN Randomized, multicenter trial conducted between January 2006 and October 2008. SETTING Ten sites serving a total catchment area of approximately 2.8 million inhabitants. PATIENTS A total of 400 patients with unresectable distal malignant biliary obstruction. INTERVENTIONS ERCP with insertion of covered or uncovered metal stent. Follow-up conducted monthly for symptoms indicating stent obstruction. MAIN OUTCOME MEASUREMENTS Time to stent failure, survival time, and complication rate. RESULTS The patient survival times were 116 days (interquartile range 242 days) and 174 days (interquartile range 284 days) in the covered and uncovered stent groups, respectively (P = .320). The first quartile stent patency time was 154 days in the covered stent group and 199 days in the uncovered stent group (P = .326). There was no difference in the incidence of pancreatitis or cholecystitis between the 2 groups. Stent migration occurred in 6 patients (3%) in the covered group and in no patients in the uncovered group (P = .030). LIMITATIONS Randomization was not blinded. CONCLUSIONS There were no significant differences in stent patency time, patient survival time, or complication rates between covered and uncovered nitinol metal stents in the palliative treatment of malignant distal biliary obstruction. However, covered stents migrated significantly more often compared with uncovered stents, and tumor ingrowth was more frequent in uncovered stents.
Collapse
|
Comparative Study |
15 |
216 |
2
|
Spada C, Hassan C, Munoz-Navas M, Neuhaus H, Deviere J, Fockens P, Coron E, Gay G, Toth E, Riccioni ME, Carretero C, Charton JP, Van Gossum A, Wientjes CA, Sacher-Huvelin S, Delvaux M, Nemeth A, Petruzziello L, de Frias CP, Mayershofer R, Amininejad L, Dekker E, Galmiche JP, Frederic M, Johansson GW, Cesaro P, Costamagna G. Second-generation colon capsule endoscopy compared with colonoscopy. Gastrointest Endosc 2011; 74:581-589.e1. [PMID: 21601200 DOI: 10.1016/j.gie.2011.03.1125] [Citation(s) in RCA: 196] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2010] [Accepted: 03/09/2011] [Indexed: 12/13/2022] [Imported: 02/09/2025]
Abstract
BACKGROUND Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. DESIGN AND SETTING Prospective, multicenter trial including 8 European sites. PATIENTS This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. INTERVENTION CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are ≥6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. MAIN OUTCOME MEASUREMENTS CCE-2 sensitivity and specificity for detecting patients with polyps ≥6 mm and ≥10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. RESULTS Per-patient CCE-2 sensitivity for polyps ≥6 mm and ≥10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. LIMITATIONS Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. CONCLUSION In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoid lesions, and it might be considered an adequate tool for colorectal imaging.
Collapse
|
Comparative Study |
14 |
196 |
3
|
Tsuda S, Veress B, Tóth E, Fork FT. Flat and depressed colorectal tumours in a southern Swedish population: a prospective chromoendoscopic and histopathological study. Gut 2002; 51:550-5. [PMID: 12235079 PMCID: PMC1773398 DOI: 10.1136/gut.51.4.550] [Citation(s) in RCA: 175] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/15/2002] [Indexed: 12/16/2022] [Imported: 02/09/2025]
Abstract
BACKGROUND Flat and depressed colorectal tumours are common in Japan but are very rare or non-existent in Western countries. AIMS To study the occurrence of flat colorectal tumours in a southern Swedish population. METHODS In this prospective study, 371 consecutive European patients were examined by high resolution video colonoscopy combined with chromoendoscopy. The nature of the lesions was determined by histopathological examination. RESULTS A total of 973 tumours were found; 907 (93.2%) were protruding and 66 (6.8%) were flat or depressed. Of the flat/depressed tumours, five (7.7%) were early adenocarcinomas infiltrating the submucosa. Eleven carcinomas (1.2%) were found among protruding tumours. High grade dysplasia was observed in 18% (n=11) of flat/depressed adenomas in contrast with 7.3% (n=65) of protruding adenomas, and occurred in smaller flat/depressed tumours compared with protruding ones (mean diameter 8 mm v 23 mm, respectively). Furthermore, high grade dysplasia was significantly more common in flat elevated tumours with central depression or in depressed adenomas (35.7%; 5/14) than in flat elevated adenomas (12.8%; 6/47). CONCLUSION Flat and depressed tumours exist in a Western population. Future studies should address whether or not chromoendoscopy with video colonoscopy is necessary in the search for flat colorectal neoplasms.
Collapse
|
research-article |
23 |
175 |
4
|
Spada C, Hassan C, Galmiche JP, Neuhaus H, Dumonceau JM, Adler S, Epstein O, Gay G, Pennazio M, Rex DK, Benamouzig R, de Franchis R, Delvaux M, Devière J, Eliakim R, Fraser C, Hagenmuller F, Herrerias JM, Keuchel M, Macrae F, Munoz-Navas M, Ponchon T, Quintero E, Riccioni ME, Rondonotti E, Marmo R, Sung JJ, Tajiri H, Toth E, Triantafyllou K, Van Gossum A, Costamagna G. Colon capsule endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline. Endoscopy 2012; 44:527-36. [PMID: 22389230 DOI: 10.1055/s-0031-1291717] [Citation(s) in RCA: 160] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] [Imported: 02/09/2025]
Abstract
PillCam colon capsule endoscopy (CCE) is an innovative noninvasive, and painless ingestible capsule technique that allows exploration of the colon without the need for sedation and gas insufflation. Although it is already available in European and other countries, the clinical indications for CCE as well as the reporting and work-up of detected findings have not yet been standardized. The aim of this evidence-based and consensus-based guideline, commissioned by the European Society of Gastrointestinal Endoscopy (ESGE) is to furnish healthcare providers with a comprehensive framework for potential implementation of this technique in a clinical setting.
Collapse
|
Practice Guideline |
13 |
160 |
5
|
Rondonotti E, Pennazio M, Toth E, Menchen P, Riccioni ME, De Palma GD, Scotto F, De Looze D, Pachofsky T, Tacheci I, Havelund T, Couto G, Trifan A, Kofokotsios A, Cannizzaro R, Perez-Quadrado E, de Franchis R. Small-bowel neoplasms in patients undergoing video capsule endoscopy: a multicenter European study. Endoscopy 2008; 40:488-95. [PMID: 18464193 DOI: 10.1055/s-2007-995783] [Citation(s) in RCA: 142] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] [Imported: 02/09/2025]
Abstract
BACKGROUND AND STUDY AIM Small-bowel tumors account for 1% - 3% of all gastrointestinal neoplasms. Recent studies with video capsule endoscopy (VCE) suggest that the frequency of these tumors may be substantially higher than previously reported. The aim of the study was to evaluate the frequency, clinical presentation, diagnostic/therapeutic work-up, and endoscopic appearance of small-bowel tumors in a large population of patients undergoing VCE. PATIENTS AND METHODS Identification by a questionnaire of patients with VCE findings suggesting small-bowel tumors and histological confirmation of the neoplasm seen in 29 centers of 10 European Countries. RESULTS Of 5129 patients undergoing VCE, 124 (2.4%) had small-bowel tumors (112 primary, 12 metastatic). Among these patients, indications for VCE were: obscure gastrointestinal bleeding (108 patients), abdominal pain (9), search for primary neoplasm (6), diarrhea with malabsorption (1). The main primary small-bowel tumor type was gastrointestinal stromal tumor (GIST) (32%) followed by adenocarcinoma (20%) and carcinoid (15%); 66% of secondary small-bowel tumors were melanomas. Of the tumors, 80.6% were identified solely on the basis of VCE findings. 55 patients underwent VCE as the third procedure after negative bidirectional endoscopy. The lesions were single in 89.5% of cases, and multiple in 10.5%. Retention of the capsule occurred in 9.8% of patients with small-bowel tumors. After VCE, 54/124 patients underwent 57 other examinations before treatment; in these patients enteroscopy, when performed, showed a high diagnostic yield. Treatment was surgery in 95% of cases. CONCLUSIONS Our data suggest that VCE detects small-bowel tumors in a small proportion of patients undergoing this examination, but the early use of this tool can shorten the diagnostic work-up and influence the subsequent management of these patients.
Collapse
|
|
17 |
142 |
6
|
Small bowel capsule endoscopy in the management of established Crohn's disease: clinical impact, safety, and correlation with inflammatory biomarkers. Inflamm Bowel Dis 2015; 21:93-100. [PMID: 25517597 DOI: 10.1097/mib.0000000000000255] [Citation(s) in RCA: 93] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] [Imported: 02/09/2025]
Abstract
BACKGROUND Multiple studies have established the superior diagnostic accuracy of video capsule endoscopy (VCE) for the diagnosis of small bowel (SB) Crohn's disease (CD). However, data on the clinical impact of VCE in patients with established CD are scarce. The aim of this study was to examine the impact and safety of VCE on the clinical management of patients with established CD. METHODS A retrospective, multicenter, cross-sectional study. The study cohort included consecutive patients with established SB CD who underwent VCE in 4 tertiary referral centers (1 Canada, 1 Sweden, and 2 United Kingdom) from January 2008 to October 2013. Patients were excluded if VCE was performed as a part of the initial diagnostic workup. The presence of SB mucosal inflammation was quantified using the Lewis score. Inflammatory biomarkers (C-reactive protein and fecal calprotectin) were measured and correlated with the Lewis score. RESULTS The study included 187 patients. No SB inflammation was observed in 28.4%, mild-to-moderate inflammation in 26.6%, and moderate-to-severe inflammation in 45% of the patients (median Lewis score, 662; range, 0-6400). A change in management was recommended in 52.3% of the patients based on VCE findings. Elevated C-reactive protein, fecal calprotectin, or the combination of both were poorly correlated with significant SB inflammation. SB capsule retention occurred in 4 patients (2.1%). CONCLUSIONS VCE in patients with established CD is safe, and the results often have a significant clinical impact. VCE should not be limited to CD patients with positive inflammatory markers because their predictive value for significant SB inflammation is poor.
Collapse
|
Multicenter Study |
10 |
93 |
7
|
Halttunen J, Meisner S, Aabakken L, Arnelo U, Grönroos J, Hauge T, Kleveland PM, Nordblad Schmidt P, Saarela A, Swahn F, Toth E, Mustonen H, Löhr JM. Difficult cannulation as defined by a prospective study of the Scandinavian Association for Digestive Endoscopy (SADE) in 907 ERCPs. Scand J Gastroenterol 2014; 49:752-8. [PMID: 24628493 DOI: 10.3109/00365521.2014.894120] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] [Imported: 02/09/2025]
Abstract
BACKGROUND The definition of a "difficult" cannulation varies considerably in reports of endoscopic retrograde cholangiopancreatography (ERCP). AIMS To define a difficult cannulation, which translates into higher risk of post-ERCP pancreatitis. PATIENTS AND METHODS Prospective consecutive recording of 907 cannulations in Scandinavian centers done by experienced endoscopists. Inclusion: indication for biliary access in patients with intact papilla. Exclusion: acute non-biliary and chronic pancreatitis at time of procedure. RESULTS The primary cannulation succeeded in 74.9%, with median values for time 0.88 min (53 s), with two attempts and with zero pancreatic passages or injections. The overall cannulation success was 97.4% and post-ERCP pancreatitis (PEP) rate was 5.3%. The median time for all successful cannulations was 1.55 min (range 0.02-94.2). If the primary cannulation succeeded, the pancreatitis rate was 2.8%; after secondary methods, it rose to 11.5%. Procedures lasting less than 5 min had a PEP rate of 2.6% versus 11.8% in those lasting longer. With one attempt, the PEP rate was 0.6%, with two 3.1%, with three to four 6.1%, and with five and more 11.9%. With one accidental pancreatic guide-wire passage, the risk of the PEP was 3.7%, and with two passages, it was 13.1%. CONCLUSIONS If the increasing rate of PEP is taken as defining factor, the wire-guided cannulation of a native papilla can be considered difficult after 5 min, five attempts, and two pancreatic guide-wire passages when any of those limits is exceeded.
Collapse
|
|
11 |
92 |
8
|
Fork FT, Lafolie P, Tóth E, Lindgärde F. Gastroduodenal tolerance of 75 mg clopidogrel versus 325 mg aspirin in healthy volunteers. A gastroscopic study. Scand J Gastroenterol 2000; 35:464-9. [PMID: 10868447 DOI: 10.1080/003655200750023705] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] [Imported: 02/09/2025]
Abstract
BACKGROUND Clopidogrel is a new antiplatelet agent that offers increased protection over aspirin in preventing vascular ischaemic events in patients with symptomatic atherosclerosis. In a large, randomized, international study of clopidogrel and aspirin (n = 19,185 patients) clopidogrel was associated with a lower incidence of gastrointestinal adverse events, including gastrointestinal haemorrhage and hospitalizations because of gastrointestinal haemorrhage. The aim of the study was to determine whether macroscopic differences in the gastric mucosa between aspirin- and clopidogrel-treated subjects could be detected by gastroscopy after short-term treatment. METHODS Thirty-six healthy volunteers were randomized in a double-blind, double-dummy, parallel design, to 75 mg/day of clopidogrel or 325 mg/day of aspirin for 8 days. Gastroscopy was performed at base line before administration of study drug and directly after treatment completion. Gastroduodenal effects were measured in accordance with a modified Lanza scale. RESULTS At base line no difference between the groups was detected (median Lanza score, 0.0 in both groups). At the end of treatment the aspirin group showed a median score of 7.5, and the clopidogrel group showed an unchanged median score of 0.0 (P < 0.001). In the aspirin group 13 individuals reported 19 adverse events versus 8 individuals and 13 adverse events for clopidogrel, with approximately half of the adverse events being gastrointestinal in each group. No serious adverse events were reported. CONCLUSION In contrast to aspirin, short-term treatment with clopidogrel does not induce macroscopic changes in the gastroduodenal mucosa. The study results show that in patients without gastroduodenal disease clopidogrel, but not aspirin, does not induce any gastroscopically evident erosions during short-term treatment.
Collapse
|
Clinical Trial |
25 |
77 |
9
|
Froehlich F, Harris JK, Wietlisbach V, Burnand B, Vader JP, Gonvers JJ. Current sedation and monitoring practice for colonoscopy: an International Observational Study (EPAGE). Endoscopy 2006; 38:461-9. [PMID: 16767580 DOI: 10.1055/s-2006-925368] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] [Imported: 02/09/2025]
Abstract
BACKGROUND AND STUDY AIMS Sedation and monitoring practice during colonoscopy varies between centers and over time. Knowledge of current practice is needed to ensure quality of care and help focus future research. The objective of this study was to examine sedation and monitoring practice in endoscopy centers internationally. PATIENTS AND METHODS This observational study included consecutive patients referred for colonoscopy at 21 centers in 11 countries. Endoscopists reported sedation and monitoring practice, using a standard questionnaire for each patient. RESULTS 6004 patients were included in this study, of whom 53 % received conscious/moderate sedation during colonoscopy, 30 % received deep sedation, and 17 % received no sedation. Sedation agents most commonly used were midazolam (47 %) and opioids (33 %). Pulse oximetry was done during colonoscopy in 77 % of patients, blood pressure monitoring in 34 %, and electrocardiography in 24 %. Pulse oximetry was most commonly used for moderately sedated patients, while blood pressure monitoring and electrocardiography were used predominantly for deeply sedated patients. Sedation and monitoring use ranged from 0 % to 100 % between centers. Oxygen desaturation (</= 85 %) occurred in 5 % of patients, of whom 80 % were moderately sedated. On average, three staff members were involved in procedures. An anesthesiologist was present during 27 % of colonoscopies, and during 85 % of colonoscopies using deep sedation. CONCLUSIONS Internationally, sedation and monitoring practice during colonoscopy varied widely. Moderate sedation was the most common sedation method used and electronic monitoring was used in three-quarters of patients. Deep sedation tended to be more resource-intensive, implying a greater use of staff and monitoring.
Collapse
|
Multicenter Study |
19 |
65 |
10
|
Lymphovascular Infiltration, Not Depth of Invasion, is the Critical Risk Factor of Metastases in Early Colorectal Cancer: Retrospective Population-based Cohort Study on Prospectively Collected Data, Including Validation. Ann Surg 2020; 275:e148-e154. [PMID: 32187031 DOI: 10.1097/sla.0000000000003854] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] [Imported: 02/09/2025]
Abstract
OBJECTIVE To identify clinical and histopathological risk factors of LNM in T1 CRC. SUMMARY OF BACKGROUND DATA The requisite of additional surgery after locally resected T1 CRC is dependent on the risk of LNM. Depth of submucosal invasion is used as a key predictor of lymphatic metastases although data are conflicting on its actual impact. METHODS Retrospective population-based cohort study on prospectively collected data on all patients with T1 CRC undergoing surgical resection in Sweden, 2009-2017 and Denmark 2016-2018. The Danish cohort was used for validation. Potential risk factors of LNM investigated were; age, sex, tumor location, submucosal invasion, grade of differentiation, mucinous subtype, lymphovascular, and perineural invasion. RESULTS One hundred fifty out of the 1439 included patients (10%) had LNM. LVI (P < 0.001), perineural invasion (P < 0.001), mucinous subtype (P = 0.006), and age <60 years (P < 0.001) were identified as independent risk factors whereas deep submucosal invasion was only a dependent (P = 0.025) risk factor and not significant in multivariate analysis (P = 0.075). The incidence of LNM was 51/882 (6%) in absence of the independent risk factors. The Danish validation cohort, confirmed our findings regarding the role of submucosal invasion, LVI, and age. CONCLUSIONS This is a large study on LNM in T1 CRC, including validation, showing that LVI and perineural invasion, mucinous subtype, and low age constitute independent risk factors, whereas depth of submucosal invasion is not an independent risk factor of LNM. Thus, our findings provide a useful basis for management of patients after local excision of early CRC.
Collapse
|
Journal Article |
5 |
62 |
11
|
Mathus-Vliegen E, Pellisé M, Heresbach D, Fischbach W, Dixon T, Belsey J, Parente F, Rio-Tinto R, Brown A, Toth E, Crosta C, Layer P, Epstein O, Boustiere C. Consensus guidelines for the use of bowel preparation prior to colonic diagnostic procedures: colonoscopy and small bowel video capsule endoscopy. Curr Med Res Opin 2013; 29:931-45. [PMID: 23659560 DOI: 10.1185/03007995.2013.803055] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] [Imported: 02/09/2025]
Abstract
BACKGROUND Adequate bowel preparation prior to colonic diagnostic procedures is essential to ensure adequate visualisation. SCOPE This consensus aims to provide guidance as to the appropriate use of bowel preparation for a range of defined clinical circumstances. A consensus group from across Europe was convened and met to discuss appropriate bowel preparation. The use of polyethylene glycol (PEG), sodium picosulphate and sodium phosphate (NaP), together with other agents, prokinetics and simethicone, in colonoscopy and small bowel video capsule endoscopy were considered. A systematic review of the literature was carried out and additional unpublished data was obtained from the members of the consensus group where required. Recommendations were graded according to the level of evidence. FINDINGS PEG-based regimens are recommended first line for both procedures, since their use is supported by good efficacy and safety data. Sodium-picosulphate-based regimens are recommended second line as their cleansing efficacy appears less than PEG-based regimens. NaP is not recommended for bowel cleansing due to the potential for renal damage and other adverse events. However, the use of NaP is acceptable in patients in whom PEG or sodium picosulphate is ineffective or not tolerated. NaP should not be used in patients with chronic kidney disease, pre-existing electrolyte disturbances, congestive heart failure, cirrhosis or a history of hypertension. The timing of the dose, dietary restrictions, use in special patient groups and recording of the quality of bowel preparation are also considered for patients undergoing colonoscopy. During the development of the guidelines the European Society of Gastrointestinal Endoscopy (ESGE) issued guidance on bowel preparation for colonoscopy. The ESGE guidelines and these consensus guidelines share many recommendations; differences between the guidelines are reviewed. CONCLUSION The use of bowel preparation should be tailored to the individual patient and their specific clinical circumstances.
Collapse
|
|
12 |
61 |
12
|
Haraldsson E, Kylänpää L, Grönroos J, Saarela A, Toth E, Qvigstad G, Hult M, Lindström O, Laine S, Karjula H, Hauge T, Sadik R, Arnelo U. Macroscopic appearance of the major duodenal papilla influences bile duct cannulation: a prospective multicenter study by the Scandinavian Association for Digestive Endoscopy Study Group for ERCP. Gastrointest Endosc 2019; 90:957-963. [PMID: 31326385 DOI: 10.1016/j.gie.2019.07.014] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Accepted: 07/10/2019] [Indexed: 12/11/2022] [Imported: 02/09/2025]
Abstract
BACKGROUND AND AIMS Certain appearances of the major duodenal papilla have been claimed to make cannulation more difficult during ERCP. This study uses a validated classification of the endoscopic appearance of the major duodenal papilla to determine if certain types of papilla predispose to difficult cannulation. METHODS Patients with a naïve papilla scheduled for ERCP were included. The papilla was classified into 1 of 4 papilla types before cannulation started. Time to successful bile duct cannulation, attempts, and number of pancreatic duct passages were recorded. Difficult cannulation was defined as after 5 minutes, 5 attempts, or 2 pancreatic guidewire passages. RESULTS A total of 1401 patients were included from 9 different centers in the Nordic countries. The overall frequency of difficult cannulation was 42% (95% confidence interval [CI], 39%-44%). Type 2 small papilla (52%; 95% CI, 45%-59%) and type 3 protruding or pendulous papilla (48%; 95% CI, 42%-53%) were more frequently difficult to cannulate compared with type 1 regular papilla (36%; 95% CI, 33%-40%; both P < .001). If an inexperienced endoscopist started cannulation, the frequency of failed cannulation increased from 1.9% to 6.3% (P < .0001), even though they were replaced by a senior endoscopist after 5 minutes. CONCLUSIONS The endoscopic appearance of the major duodenal papilla influences bile duct cannulation. Small type 2 and protruding or pendulous type 3 papillae are more frequently difficult to cannulate. In addition, cannulation might even fail more frequently if a beginner starts cannulation. These findings should be taken into consideration when performing studies regarding bile duct cannulation and in training future generations of endoscopists.
Collapse
|
Multicenter Study |
6 |
57 |
13
|
Clinical outcomes of negative small-bowel capsule endoscopy for small-bowel bleeding: a systematic review and meta-analysis. Gastrointest Endosc 2017; 85:305-317.e2. [PMID: 27594338 DOI: 10.1016/j.gie.2016.08.027] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Accepted: 08/23/2016] [Indexed: 12/11/2022] [Imported: 02/09/2025]
Abstract
BACKGROUND AND AIMS Small-bowel bleeding is the primary indication for capsule endoscopy (CE). Many experts advocate a "watch-and-wait" policy in negative CE. This meta-analysis examines the odds of rebleeding after negative index CE and the impact on long-term follow-up. METHODS A comprehensive literature search identified articles examining the rebleeding rate after negative CE. Demographic and clinical information with emphasis on outcomes was retrieved, pooled, and analyzed. Heterogeneity among studies was assessed using the I2 statistic. A random effects model was used as the pooling method because of high heterogeneity. Risk of bias was assessed using the quality assessment of diagnostic accuracy studies (QUADAS-2) tool. The primary outcome evaluated was the pooled odds ratios (ORs) for rebleeding after a negative CE for obscure GI bleeding (OGIB). RESULTS Twenty-six studies with 3657 patients were included. The pooled rate of rebleeding after negative CE was .19 (95% CI, .14-.25; P < .0001). The pooled OR of rebleeding was .59 (95% CI, .37-.95; P < .001). The effect was more pronounced in studies with a short follow-up (OR, .47; 95% CI, .24-.94; P < .001). There was no statistically significant difference in rebleeding after CE for occult and overt OGIB. Prospective studies showed a lower OR of rebleeding of .24 (95% CI, .08-.73; P = .01). Most studies were high quality. CONCLUSIONS Our analysis shows that negative CE provides adequate evidence of a subsequently low risk of rebleeding. Such patients can therefore be safely managed with watchful waiting. However, patients who rebleed after 2 years may need to be investigated for a new source of blood loss.
Collapse
|
Meta-Analysis |
8 |
51 |
14
|
Fischer H, Holst E, Karlsson F, Benoni C, Toth E, Olesen M, Lindén M, Sjöberg K. Altered microbiota in microscopic colitis. Gut 2015; 64:1185-6. [PMID: 25841239 PMCID: PMC4483788 DOI: 10.1136/gutjnl-2014-308956] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Accepted: 02/07/2015] [Indexed: 12/12/2022] [Imported: 02/09/2025]
|
letter |
10 |
50 |
15
|
Haraldsson E, Lundell L, Swahn F, Enochsson L, Löhr JM, Arnelo U. Endoscopic classification of the papilla of Vater. Results of an inter- and intraobserver agreement study. United European Gastroenterol J 2016; 5:504-510. [PMID: 28588881 DOI: 10.1177/2050640616674837] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2016] [Accepted: 09/25/2016] [Indexed: 12/20/2022] [Imported: 02/09/2025] Open
Abstract
BACKGROUND Many endoscopists acknowledge that the appearance of the papilla of Vater seems to affect biliary cannulation. To assess the association between the macroscopic appearance of the papilla and biliary cannulation and other related clinical issues, a system is needed to define the appearance of the papilla. OBJECTIVE The purpose of this study was to validate an endoscopic classification of the papilla of Vater by assessing the interobserver and intraobserver agreements among endoscopist with varying experience. METHODS An endoscopic classification, based on pictures captured from 140 different papillae, containing four types of papillae was proposed. The four types are (a) Type 1: regular papilla, no distinctive features, 'classic appearance'; (b) Type 2: small papilla, often flat, with a diameter ≤ 3 mm (approximately 9 Fr); (c) Type 3: protruding or pendulous papilla, a papilla that is standing out, protruding or bulging into the duodenal lumen or sometimes hanging down, pendulous with the orifice oriented caudally; and (d) Type 4: creased or ridged papilla, where the ductal mucosa seems to extend distally, rather out of the papillary orifice, either on a ridge or in a crease. To assess the level of interobserver agreement, a web-based survey was sent out to 18 endoscopists, containing 50 sets of still images of the papilla, distributed between the four different types. Three months later a follow-up survey, with images from the first survey was sent to the same endoscopists. RESULTS Interobserver agreement was substantial (κ = 0.62, 95% confidence interval (CI) 0.58-0.65) and were similar for both experts and non-experts. The intraobserver agreement assessed with the second survey was also substantial (κ = 0.66, 95% CI 0.59-0.72). CONCLUSION The proposed endoscopic classification of the papilla of Vater seems to be easy to use, irrespective of the level of experience of the endoscopist. It carries a substantial inter- and intraobserver agreement and now the clinical relevance of the four different papilla types awaits to be determined.
Collapse
|
Journal Article |
9 |
49 |
16
|
Hawkey CJ, Ell C, Simon B, Albert J, Keuchel M, McAlindon M, Fortun P, Schumann S, Bolten W, Shonde A, Hugot JL, Yu V, Arulmani U, Krammer G, Rebuli R, Toth E. Less small-bowel injury with lumiracoxib compared with naproxen plus omeprazole. Clin Gastroenterol Hepatol 2008; 6:536-44. [PMID: 18242145 DOI: 10.1016/j.cgh.2007.12.023] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] [Imported: 02/09/2025]
Abstract
BACKGROUND & AIMS The selective cyclooxygenase-2 inhibitor lumiracoxib has been shown to reduce endoscopically detected ulcers and ulcer complications in the upper gastrointestinal tract compared with nonselective nonsteroidal anti-inflammatory drugs. We investigated whether lumiracoxib would reduce small-bowel injury compared with naproxen plus omeprazole. METHODS Healthy volunteers were randomized to receive lumiracoxib 100 mg once daily, naproxen 500 mg twice daily plus omeprazole 20 mg once daily, or placebo in a 16-day double-blind, parallel-group study. Small-bowel mucosal injury and inflammation were assessed by video capsule endoscopy, the lactulose:L-rhamnose permeability assessment, and the fecal calprotectin test. RESULTS Of 152 randomized subjects, 139 completed the study with valid video capsule endoscopies (lumiracoxib, n = 47; naproxen plus omeprazole, n = 45; placebo, n = 47). Compared with placebo, an increased number of subjects on naproxen plus omeprazole had small-bowel mucosal breaks (77.8% vs 40.4%, P < .001), with increased permeability (P = .023) and increased fecal calprotectin (increase, 96.8 vs 14.5 mg/kg for placebo; P < .001). With lumiracoxib, 27.7% of subjects had small-bowel mucosal breaks (P = .196 vs placebo; P < .001 vs naproxen), there was no increase in permeability (P = .157 vs placebo; P = .364 vs naproxen), and no increase in fecal calprotectin (-5.7 mg/kg; P = .377 vs placebo; P < .001 vs naproxen). CONCLUSIONS As assessed by 3 different measures, acute small-bowel injury on lumiracoxib treatment is less frequent than with naproxen plus omeprazole and similar to placebo.
Collapse
|
Comparative Study |
17 |
46 |
17
|
Endoscopic assessment and grading of Barrett's esophagus using magnification endoscopy and narrow-band imaging: accuracy and interobserver agreement of different classification systems (with videos). Gastrointest Endosc 2011; 73:7-14. [PMID: 21184868 DOI: 10.1016/j.gie.2010.09.023] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2010] [Accepted: 09/07/2010] [Indexed: 12/13/2022] [Imported: 02/09/2025]
Abstract
BACKGROUND Three different classification systems for the evaluation of Barrett's esophagus (BE) using magnification endoscopy (ME) and narrow-band imaging (NBI) have been proposed. Until now, no comparative and external evaluation of these systems in a clinical-like situation has been performed. OBJECTIVE To compare and validate these 3 classification systems. DESIGN Prospective validation study. SETTING Tertiary-care referral center. Nine endoscopists with different levels of expertise from Europe and Japan participated as assessors. PATIENTS Thirty-two patients with long-segment BE. INTERVENTIONS From a group of 209 standardized prospective recordings collected on BE by using ME combined with NBI, 84 high-quality videos were randomly selected for evaluation. Histologically, 28 were classified as gastric type mucosa, 29 as specialized intestinal metaplasia (SIM), and 27 as SIM with dysplasia/cancer. Assessors were blinded to underlying histology and scored each video according to the respective classification system. Before evaluation, an educational set concerning each classification system was carefully studied. At each assessment, the same 84 videos were displayed, but in different and random order. MAIN OUTCOME MEASUREMENTS Accuracy for detection of nondysplastic and dysplastic SIM. Interobserver agreement related to each classification. RESULTS The median time for video evaluation was 25 seconds (interquartile range 20-39 seconds) and was longer with the Amsterdam classification (P < .001). In 65% to 69% of the videos, assessors described certainty about the histology prediction. The global accuracy was 46% and 47% using the Nottingham and Kansas classifications, respectively, and 51% with the Amsterdam classification. The accuracy for nondysplastic SIM identification ranged between 57% (Kansas and Nottingham) and 63% (Amsterdam). Accuracy for dysplastic tissue was 75%, irrespective of the classification system and assessor expertise level. Interobserver agreement ranged from fair (Nottingham, κ = 0.34) to moderate (Amsterdam and Kansas, κ = 0.47 and 0.44, respectively). LIMITATION No per-patient analysis. CONCLUSIONS All of the available classification systems could be used in a clinical-like environment, but with inadequate interobserver agreement. All classification systems based on combined ME and NBI, revealed substantial limitations in predicting nondysplastic and dysplastic BE when assessed externally. This technique cannot, as yet, replace random biopsies for histopathological analysis.
Collapse
|
Comparative Study |
14 |
45 |
18
|
Sjöstedt S, Befrits R, Sylvan A, Harthon C, Jörgensen L, Carling L, Modin S, Stubberöd A, Toth E, Lind T. Daily treatment with esomeprazole is superior to that taken on-demand for maintenance of healed erosive oesophagitis. Aliment Pharmacol Ther 2005; 22:183-91. [PMID: 16091055 DOI: 10.1111/j.1365-2036.2005.02553.x] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] [Imported: 02/09/2025]
Abstract
BACKGROUND On-demand therapy with esomeprazole is effective for long-term treatment of non-erosive gastro-oesophageal reflux disease, but it has not been evaluated in erosive gastro-oesophageal reflux disease. AIMS To compare endoscopic and symptomatic remission over a 6-month period when patients with healed erosive gastro-oesophageal reflux disease are treated with esomeprazole 20 mg, either once daily or on-demand. METHODS Patients with verified erosive reflux oesophagitis of Los Angeles grades A-D were enrolled. Following 4-8 weeks treatment with esomeprazole 40 mg daily, those who were endoscopically healed and had symptom control during the last week were randomized to maintenance therapy for 6 months with esomeprazole 20 mg, taken either once daily or on-demand. RESULTS Of 539 enrolled patients, 494 (91%) were healed at 8 weeks and 477 were randomized to maintenance therapy with esomeprazole 20 mg, 243 once daily and 234 on-demand. After once daily treatment, 81% of patients were still in remission at 6 months, compared with only 58% who took on-demand treatment (P < 0.0001). A difference in remission was found irrespective of baseline grade of oesophagitis, but it was more pronounced for the more severe grades. There was no difference in overall symptomatic remission between the two treatments, although heartburn was significantly more prevalent in the on-demand group. CONCLUSIONS Once daily esomeprazole 20 mg was better than that taken on-demand for maintaining healed erosive oesophagitis, regardless of baseline Los Angeles grade.
Collapse
|
Clinical Trial |
20 |
45 |
19
|
Leighton JA, Gralnek IM, Cohen SA, Toth E, Cave DR, Wolf DC, Mullin GE, Ketover SR, Legnani PE, Seidman EG, Crowell MD, Bergwerk AJ, Peled R, Eliakim R. Capsule endoscopy is superior to small-bowel follow-through and equivalent to ileocolonoscopy in suspected Crohn's disease. Clin Gastroenterol Hepatol 2014; 12:609-15. [PMID: 24075891 DOI: 10.1016/j.cgh.2013.09.028] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2013] [Revised: 07/29/2013] [Accepted: 09/04/2013] [Indexed: 02/06/2023] [Imported: 02/09/2025]
Abstract
BACKGROUND & AIMS Evaluation of the small intestine for inflammation has traditionally relied on small-bowel follow-through (SBFT), but multiple studies have demonstrated its low diagnostic accuracy. Capsule endoscopy (CE) transmits high-quality images of the small intestinal mucosa; it can be used to visualize the entire length of the small bowel and much of the mucosa. We compared the diagnostic yields of CE vs SBFT in a prospective study of patients with suspected small-bowel Crohn's disease. METHODS Eighty patients with signs and/or symptoms of small-bowel Crohn's disease (age, 10-65 years) underwent CE, followed by SBFT and ileocolonoscopy. Readers were blinded to other test results. The primary outcome was the diagnostic yield for inflammatory lesions found with CE before ileocolonoscopy compared with SBFT and ileocolonoscopy. A secondary outcome was the incremental diagnostic yield of CE compared with ileocolonoscopy and CE compared with SBFT. RESULTS The combination of CE and ileocolonoscopy detected 107 of 110 inflammatory lesions (97.3%), whereas the combination of SBFT and ileocolonoscopy detected only 63 lesions (57.3%) (P < .001). The diagnostic yield of CE compared with ileocolonoscopy was not different (P = .09). The diagnostic yield was higher for CE than for SBFT (P < .001). Of the 80 patients with suspected Crohn's disease, 25 (31.3%) had the diagnosis confirmed. Eleven were diagnosed by CE findings alone and 5 by ileocolonoscopy findings alone. In the remaining 9 patients, diagnostic findings were identified by at least 2 of the 3 modalities. No diagnoses were made on the basis of SBFT findings alone. CONCLUSIONS CE was better than SBFT and equivalent to ileocolonoscopy in detecting small-bowel inflammation. Although ileocolonoscopy remains the initial diagnostic test of choice, CE is safe and can establish the diagnosis of Crohn's disease in patients when ileocolonoscopy results are negative or the terminal ileum cannot be evaluated. ClinicalTrials.gov Number: NCT00487396.
Collapse
|
Comparative Study |
11 |
43 |
20
|
Smedsrud PH, Thambawita V, Hicks SA, Gjestang H, Nedrejord OO, Næss E, Borgli H, Jha D, Berstad TJD, Eskeland SL, Lux M, Espeland H, Petlund A, Nguyen DTD, Garcia-Ceja E, Johansen D, Schmidt PT, Toth E, Hammer HL, de Lange T, Riegler MA, Halvorsen P. Kvasir-Capsule, a video capsule endoscopy dataset. Sci Data 2021; 8:142. [PMID: 34045470 PMCID: PMC8160146 DOI: 10.1038/s41597-021-00920-z] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 04/15/2021] [Indexed: 12/12/2022] [Imported: 02/09/2025] Open
Abstract
Artificial intelligence (AI) is predicted to have profound effects on the future of video capsule endoscopy (VCE) technology. The potential lies in improving anomaly detection while reducing manual labour. Existing work demonstrates the promising benefits of AI-based computer-assisted diagnosis systems for VCE. They also show great potential for improvements to achieve even better results. Also, medical data is often sparse and unavailable to the research community, and qualified medical personnel rarely have time for the tedious labelling work. We present Kvasir-Capsule, a large VCE dataset collected from examinations at a Norwegian Hospital. Kvasir-Capsule consists of 117 videos which can be used to extract a total of 4,741,504 image frames. We have labelled and medically verified 47,238 frames with a bounding box around findings from 14 different classes. In addition to these labelled images, there are 4,694,266 unlabelled frames included in the dataset. The Kvasir-Capsule dataset can play a valuable role in developing better algorithms in order to reach true potential of VCE technology.
Collapse
|
Dataset |
4 |
36 |
21
|
Blomberg J, Wenger U, Lagergren J, Arnelo U, Agustsson T, Johnsson E, Toth E, Lagergren P. Antireflux stent versus conventional stent in the palliation of distal esophageal cancer. A randomized, multicenter clinical trial. Scand J Gastroenterol 2010; 45:208-16. [PMID: 19968614 DOI: 10.3109/00365520903443860] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] [Imported: 02/09/2025]
Abstract
OBJECTIVE Patients with incurable distal esophageal or cardia cancer often need palliative stenting to relieve their dysphagia but stents passing through the cardia can cause reflux and aspiration, leading to a reduced health-related quality of life (HRQL). This study addressed the hypothesis that antireflux stenting improves HRQL compared to conventional stenting. MATERIAL AND METHODS In a single-blind, multicenter, randomized trial in patients with inoperable esophageal or cardia cancer requiring palliative stenting passing through the cardia, 65 patients were stented. Patients received either an antireflux stent (Esophageal Z-Stent with Dua antireflux valve; n = 28) or a conventional stent (Esophageal Z-stent, Ultraflex or Wallstent; n = 37). Validated questionnaires (European Organization for Research and Treatment of Cancer QLQ-C30 and QLQ-OES18) were used to collect information on HRQL at baseline and 1 and 3 months after stenting. Main outcome measurements were differences in HRQL scores between baseline and 1 and 3 months after stenting. RESULTS Scores for most aspects of HRQL were similar in the two groups, and no statistically significant differences were found. Some general symptoms however showed clinically relevant improvement in the antireflux stent group, while esophageal-specific symptoms such as dysphagia seemed clinically better, and symptoms of reflux were clinically reduced in the conventional stent group but not in the antireflux stent group. CONCLUSION This study, although limited in size, provided no obvious support for using the antireflux stent in preference to the conventional stent in the palliation of distal esophageal or cardia cancer from an HRQL perspective.
Collapse
|
Multicenter Study |
15 |
34 |
22
|
Ciuti G, Skonieczna-Żydecka K, Marlicz W, Iacovacci V, Liu H, Stoyanov D, Arezzo A, Chiurazzi M, Toth E, Thorlacius H, Dario P, Koulaouzidis A. Frontiers of Robotic Colonoscopy: A Comprehensive Review of Robotic Colonoscopes and Technologies. J Clin Med 2020; 9:E1648. [PMID: 32486374 PMCID: PMC7356873 DOI: 10.3390/jcm9061648] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 05/16/2020] [Accepted: 05/19/2020] [Indexed: 12/15/2022] [Imported: 08/29/2023] Open
Abstract
Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold standard of all population-based screening pathways around the world. Almost 60% of CRC deaths could be prevented with screening. However, colonoscopy attendance rates are affected by discomfort, fear of pain and embarrassment or loss of control during the procedure. Moreover, the emergence and global thread of new communicable diseases might seriously affect the functioning of contemporary centres performing gastrointestinal endoscopy. Innovative solutions are needed: artificial intelligence (AI) and physical robotics will drastically contribute for the future of the healthcare services. The translation of robotic technologies from traditional surgery to minimally invasive endoscopic interventions is an emerging field, mainly challenged by the tough requirements for miniaturization. Pioneering approaches for robotic colonoscopy have been reported in the nineties, with the appearance of inchworm-like devices. Since then, robotic colonoscopes with assistive functionalities have become commercially available. Research prototypes promise enhanced accessibility and flexibility for future therapeutic interventions, even via autonomous or robotic-assisted agents, such as robotic capsules. Furthermore, the pairing of such endoscopic systems with AI-enabled image analysis and recognition methods promises enhanced diagnostic yield. By assembling a multidisciplinary team of engineers and endoscopists, the paper aims to provide a contemporary and highly-pictorial critical review for robotic colonoscopes, hence providing clinicians and researchers with a glimpse of the major changes and challenges that lie ahead.
Collapse
|
Review |
5 |
32 |
23
|
Yung DE, Rondonotti E, Giannakou A, Avni T, Rosa B, Toth E, Lucendo AJ, Sidhu R, Beaumont H, Ellul P, Negreanu L, Jiménez-Garcia VA, McNamara D, Kopylov U, Elli L, Triantafyllou K, Shibli F, Riccioni ME, Bruno M, Dray X, Plevris JN, Koulaouzidis A, Argüelles-Arias F, Becq A, Branchi F, Tejero-Bustos MÁ, Cotter J, Eliakim R, Ferretti F, Gralnek IM, Herrerias-Gutierrez JM, Hussey M, Jacobs M, Johansson GW, McAlindon M, Montiero S, Nemeth A, Pennazio M, Rattehalli D, Stemate A, Tortora A, Tziatzios G. Capsule endoscopy in young patients with iron deficiency anaemia and negative bidirectional gastrointestinal endoscopy. United European Gastroenterol J 2017; 5:974-981. [PMID: 29163963 DOI: 10.1177/2050640617692501] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2016] [Accepted: 01/11/2017] [Indexed: 12/18/2022] [Imported: 02/09/2025] Open
Abstract
Background Recent data imply young patients (age ≤50 years) undergoing small-bowel (SB) capsule endoscopy (CE) for iron deficiency anaemia (IDA) show higher diagnostic yield (DY) for sinister pathology. We aimed to investigate DY of CE in a large cohort of young IDA patients, and evaluate factors predicting significant SB pathology. Materials and methods This was a retrospective, multicentre study (2010-2015) in consecutive, young patients (≤50 years) from 18 centres/12 countries, with negative bidirectional gastrointestinal (GI) endoscopy undergoing SBCE for IDA. Exclusion criteria: previous/ongoing obscure-overt GI bleeding; age <19 or >50 years; comorbidities associated with IDA. Data retrieved: SBCE indications; prior investigations; medications; SBCE findings; final diagnosis. Clinical and laboratory data were analysed by multivariate logistic regression. Results Data on 389 young IDA patients were retrieved. In total, 169 (43.4%) were excluded due to incomplete clinical data; data from 220 (122F/98M; mean age 40.5 ± 8.6 years) patients were analysed. Some 71 patients had at least one clinically significant SBCE finding (DY: 32.3%). They were divided into two groups: neoplastic pathology (10/220; 4.5%), and non-neoplastic but clinically significant pathology (61/220; 27.7%). The most common significant but non-neoplastic pathologies were angioectasias (22/61) and Crohn's disease (15/61). On multivariate analysis, weight loss and lower mean corpuscular volume(MCV) were associated with significant SB pathology (OR: 3.87; 95%CI: 1.3-11.3; p = 0.01; and OR: 0.96; 95%CI: 0.92-0.99; p = 0.03; respectively). Our model also demonstrates association between use of antiplatelets and significant SB pathology, although due to the small number of patients, definitive conclusions cannot be drawn. Conclusion In IDA patients ≤50 years with negative bidirectional GI endoscopy, overall DY of SBCE for clinically significant findings was 32.3%. Some 5% of our cohort was diagnosed with SB neoplasia; lower MCV or weight loss were associated with higher DY for SB pathology.
Collapse
|
Journal Article |
8 |
31 |
24
|
Indications, Detection, Completion and Retention Rates of Capsule Endoscopy in Two Decades of Use: A Systematic Review and Meta-Analysis. Diagnostics (Basel) 2022; 12:diagnostics12051105. [PMID: 35626261 PMCID: PMC9139699 DOI: 10.3390/diagnostics12051105] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 04/14/2022] [Accepted: 04/26/2022] [Indexed: 12/17/2022] [Imported: 02/09/2025] Open
Abstract
Background: Capsule endoscopy (CE) has become a widespread modality for non-invasive evaluation of the gastrointestinal (GI) tract, with several CE models having been developed throughout the years. The aim of this systematic review and meta-analysis is to evaluate performance measures such as completion, detection and retention rates of CE. Methods: Literature through to August 2021 was screened for articles regarding all capsule types: small bowel, double-headed capsule for the colon or PillCam®Crohn’s capsule, magnetically-controlled capsule endoscopy, esophageal capsule and patency capsule. Primary outcomes included detection rate (DR), completion rate (CR) and capsule retention rate (RR). DR, CR and RR were also analyzed in relation to indications such as obscure GI bleeding (OGIB), known/suspected Crohn’s disease (CD), celiac disease (CeD), neoplastic lesions (NL) and clinical symptoms (CS). Results: 328 original articles involving 86,930 patients who underwent CE were included. OGIB was the most common indication (n = 44,750), followed by CS (n = 17,897), CD (n = 11,299), NL (n = 4989) and CeD (n = 947). The most used capsule type was small bowel CE in 236 studies. DR, CR and RR for all indications were 59%, 89.6% and 2%, respectively. According to specific indications: DR were 55%, 66%, 63%, 52% and 62%; CR were 90.6%, 86.5%, 78.2%, 94% and 92.8%; and RR were 2%, 4%, 1%, 6% and 2%. Conclusions: Pooled DR, CR and RR are acceptable for all capsule types. OGIB is the most common indication for CE. Technological advancements have expanded the scope of CE devices in detecting GI pathology with acceptable rates for a complete examination.
Collapse
|
Review |
3 |
31 |
25
|
Clinical validity of flexible spectral imaging color enhancement (FICE) in small-bowel capsule endoscopy: a systematic review and meta-analysis. Endoscopy 2017; 49:258-269. [PMID: 28122387 DOI: 10.1055/s-0042-122015] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022] [Imported: 02/09/2025]
Abstract
Patients and methods A comprehensive literature search was conducted. We measured pooled rate of lesion visualization improvement and improvement in lesion detection comparing FICE settings 1 - 3 and WLE, for angioectasias and ulcers/erosions. Pooled results were derived using the random-effects model because of high heterogeneity as measured by I2. Repeated-measures analysis of variance (ANOVA) was used to measure differences in lesion detection between WLE and the three FICE modes. Results 13 studies were analyzed. All studies used the PillCam SB 1 and/or SB 2 devices. Most used experienced readers. Improvement in delineation had been investigated in 4 studies; in the 3 studies entered into the meta-analysis, using FICE setting 1, 89 % of angioectasias and 45 % of ulcer/erosions were considered to show improved delineation. For FICE settings 2 and 3, small proportions of images showed improved delineation. Heterogeneity of studies was high with I2 > 90 % in 4/6 analyses. Lesion detection had been investigated in 10 studies; meta-analysis included 5 studies. Lesion detection did not differ significantly between any of the FICE modes and WLE. Conclusions Overall, the use of the three FICE modes did not significantly improve delineation or detection rate in SBCE. In pigmented lesions, FICE setting 1 performed better in lesion delineation and detection.
Collapse
|
Meta-Analysis |
8 |
30 |