1
|
Elli L, Marinoni B, Sidhu R, Bojarski C, Branchi F, Tontini GE, Chetcuti Zammit S, Khater S, Eliakim R, Rondonotti E, Saurin JC, Bruno M, Buchkremer J, Cadoni S, Cavallaro F, Dray X, Ellul P, Urien IF, Keuchel M, Kopylov U, Koulaouzidis A, Leenhardt R, Baltes P, Beaumont H, Marmo C, McNamara D, Mussetto A, Nemeth A, Cuadrado Robles EP, Perrod G, Rahmi G, Riccioni ME, Robertson A, Spada C, Toth E, Triantafyllou K, Wurm Johansson G, Rimondi A. Nomenclature and Definition of Atrophic Lesions in Small Bowel Capsule Endoscopy: A Delphi Consensus Statement of the International CApsule endoscopy REsearch (I-CARE) Group. Diagnostics (Basel) 2022; 12:diagnostics12071704. [PMID: 35885608 PMCID: PMC9325291 DOI: 10.3390/diagnostics12071704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Revised: 06/25/2022] [Accepted: 07/07/2022] [Indexed: 11/16/2022] [Imported: 08/29/2023] Open
Abstract
(1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.
Collapse
|
2
|
Bednarska O, Nyhlin N, Schmidt PT, Johansson GW, Toth E, Lindfors P. The Effectiveness and Tolerability of a Very Low-Volume Bowel Preparation for Colonoscopy Compared to Low and High-Volume Polyethylene Glycol-Solutions in the Real-Life Setting. Diagnostics (Basel) 2022; 12:diagnostics12051155. [PMID: 35626310 PMCID: PMC9140572 DOI: 10.3390/diagnostics12051155] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 04/30/2022] [Accepted: 04/30/2022] [Indexed: 02/04/2023] [Imported: 08/29/2023] Open
Abstract
Adequate bowel cleansing is essential for high-quality colonoscopy. Recently, a new very low-volume 1 litre (1L) polyethylene glycol (PEG) plus ascorbate solution (ASC) has been introduced. Our aims were to assess the effectiveness and tolerability of this product compared to low-volume 2L PEG-ASC and high-volume 4L PEG solutions, in a real-life setting. In six endoscopy units in Sweden, outpatients undergoing colonoscopy were either prescribed solutions according to local routines, or the very low-volume solution in split dose regimen. Bowel cleansing effectiveness and patient experience was assessed using the Boston Bowel preparation scale (BBPS) and a patient questionnaire. A total of 1098 patients (mean age 58 years, 52% women) were included. All subsegment and the total BBPS scores were significantly greater for 1L PEG-ASC in comparison to other solutions (p < 0.05 for 1L PEG-ASC and 4L PEG for transverse and left colon, otherwise p < 0.001). Nausea was more frequent with 1L PEG-ASC compared to 2L PEG-ASC (p < 0.001) and vomiting were more often reported compared to both other solutions (p < 0.01 and p < 0.05 for 2L PEG-ASC and 4L PEG, respectively). Smell, taste, and total experience was better for 1L PEG-ASC compared to 4L PEG (p < 0.001), and similar compared to the 2L PEG-ASC. In conclusion, 1L PEG-ASC leads to better bowel cleansing compared to 2L PEG-ASC or 4L PEG products, with similar or greater patient satisfaction.
Collapse
|
3
|
Spada C, Koulaouzidis A, Hassan C, Amaro P, Agrawal A, Brink L, Fischbach W, Hünger M, Jover R, Kinnunen U, Ono A, Patai Á, Pecere S, Petruzziello L, Riemann JF, Staines H, Stringer AL, Toth E, Antonelli G, Fuccio L. Factors Associated with Withdrawal Time in European Colonoscopy Practice: Findings of the European Colonoscopy Quality Investigation (ECQI) Group. Diagnostics (Basel) 2022; 12:diagnostics12020503. [PMID: 35204593 PMCID: PMC8871420 DOI: 10.3390/diagnostics12020503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 02/02/2022] [Accepted: 02/03/2022] [Indexed: 11/30/2022] [Imported: 08/29/2023] Open
Abstract
The European Colonoscopy Quality Investigation (ECQI) Group aims to raise awareness for improvement in colonoscopy standards across Europe. We analyzed data collected on a sample of procedures conducted across Europe to evaluate the achievement of the European Society of Gastrointestinal Endoscopy (ESGE) mean withdrawal time (WT) target. We also investigated factors associated with WT, in the hope of establishing areas that could lead to a quality improvement. Methods: 6445 form completions from 12 countries between 2 June 2016 and 30 April 2018 were considered for this analysis. We performed an exploratory analysis looking at WT according to the ESGE definition. Stepwise multivariable logistic regression analysis was conducted to determine the most influential associated factors after adjusting for the other pre-specified variables. Results: In 1150 qualifying colonoscopies, the mean WT was 7.8 min. Stepwise analysis, including 587 procedures where all inputs were known, found that the variables most associated with mean WT were a previous total colonoscopy in the last five years (p = 0.0011) and the time of day the colonoscopy was performed (p = 0.0192). The main factor associated with a WT < 6 min was the time of day that a colonoscopy was performed. Use of sedation was the main factor associated with a higher proportion of WT > 10 min, along with a previous colonoscopy. Conclusions: On average, the sample of European practice captured by the ECQI survey met the minimum standard set by the ESGE. However, there was variation and potential for improvement.
Collapse
|
4
|
Rosvall A, Annersten Gershater M, Kumlien C, Toth E, Axelsson M. Patient-Reported Experience Measures for Colonoscopy: A Systematic Review and Meta-Ethnography. Diagnostics (Basel) 2022; 12:diagnostics12020242. [PMID: 35204332 PMCID: PMC8871001 DOI: 10.3390/diagnostics12020242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 01/17/2022] [Indexed: 12/10/2022] [Imported: 08/29/2023] Open
Abstract
Patient experience is defined as a major quality indicator that should be routinely measured during and after a colonoscopy, according to current ESGE guidelines. There is no standard approach measuring patient experience after the procedure and the comparative performance of the different colonoscopy-specific patient-reported experience measures (PREMs) is unclear. Therefore, the aim was to develop a conceptual model describing how patients experience a colonoscopy, and to compare the model against colonoscopy-specific PREMs. A systematic search for qualitative research published up to December 2021 in PubMed, Cochrane, CINAHL, and PsycINFO was conducted. After screening and quality assessment, data from 13 studies were synthesised using meta-ethnography. Similarities and differences between the model and colonoscopy-specific PREMs were identified. A model consisting of five concepts describes how patients experience undergoing a colonoscopy: health motivation, discomfort, information, a caring relationship, and understanding. These concepts were compared with existing PREMs and the result shows that there is agreement between the model and existing PREMs for colonoscopy in some parts, while partial agreement or no agreement is present in others. These findings suggest that new PREMs for colonoscopy should be developed, since none of the existing colonoscopy-specific PREMs fully cover patients’ experiences.
Collapse
|
5
|
Leenhardt R, Fernandez-Urien Sainz I, Rondonotti E, Toth E, Van de Bruaene C, Baltes P, Rosa BJ, Triantafyllou K, Histace A, Koulaouzidis A, Dray X. PEACE: Perception and Expectations toward Artificial Intelligence in Capsule Endoscopy. J Clin Med 2021; 10:jcm10235708. [PMID: 34884410 PMCID: PMC8658716 DOI: 10.3390/jcm10235708] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 11/22/2021] [Accepted: 11/22/2021] [Indexed: 12/16/2022] [Imported: 08/29/2023] Open
Abstract
Artificial intelligence (AI) has shown promising results in digestive endoscopy, especially in capsule endoscopy (CE). However, some physicians still have some difficulties and fear the advent of this technology. We aimed to evaluate the perceptions and current sentiments toward the use of AI in CE. An online survey questionnaire was sent to an audience of gastroenterologists. In addition, several European national leaders of the International CApsule endoscopy REsearch (I CARE) Group were asked to disseminate an online survey among their national communities of CE readers (CER). The survey included 32 questions regarding general information, perceptions of AI, and its use in daily life, medicine, endoscopy, and CE. Among 380 European gastroenterologists who answered this survey, 333 (88%) were CERs. The mean average time length of experience in CE reading was 9.9 years (0.5–22). A majority of CERs agreed that AI would positively impact CE, shorten CE reading time, and help standardize reporting in CE and characterize lesions seen in CE. Nevertheless, in the foreseeable future, a majority of CERs disagreed with the complete replacement all CE reading by AI. Most CERs believed in the high potential of AI for becoming a valuable tool for automated diagnosis and for shortening the reading time. Currently, the perception is that AI will not replace CE reading.
Collapse
|
6
|
Deding U, Cortegoso Valdivia P, Koulaouzidis A, Baatrup G, Toth E, Spada C, Fernández-Urién I, Pennazio M, Bjørsum-Meyer T. Patient-Reported Outcomes and Preferences for Colon Capsule Endoscopy and Colonoscopy: A Systematic Review with Meta-Analysis. Diagnostics (Basel) 2021; 11:1730. [PMID: 34574071 PMCID: PMC8468090 DOI: 10.3390/diagnostics11091730] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 09/15/2021] [Accepted: 09/18/2021] [Indexed: 12/22/2022] [Imported: 08/29/2023] Open
Abstract
Colon capsule endoscopy as an alternative to colonoscopy for the diagnosis of colonic disease may serve as a less invasive and more tolerable investigation for patients. Our aim was to examine patient-reported outcomes for colon capsule endoscopy compared to conventional optical colonoscopy including preference of investigation modality, tolerability and adverse events. A systematic literature search was conducted in Web of Science, PubMed and Embase. Search results were thoroughly screened for in- and exclusion criteria. Included studies underwent assessment of transparency and completeness, after which, data for meta-analysis were extracted. Pooled estimates of patient preference were calculated and heterogeneity was examined including univariate meta-regressions. Patient-reported tolerability and adverse events were reviewed. Out of fourteen included studies, twelve had investigated patient-reported outcomes in patients who had undergone both investigations, whereas in two the patients were randomized between investigations. Pooled patient preferences were estimated to be 52% (CI 95%: 41-63%) for colon capsule endoscopy and 45% (CI 95%: 33-57%) for conventional colonoscopy: not indicating a significant difference. Procedural adverse events were rarely reported by patients for either investigation. The tolerability was high for both colon capsule endoscopy and conventional colonoscopy. Patient preferences for conventional colonoscopy and colon capsule endoscopy were not significantly different. Procedural adverse events were rare and the tolerability for colon capsule endoscopy was consistently reported higher or equal to that of conventional colonoscopy.
Collapse
|
7
|
Balloon-Assisted Colonoscopy after Incomplete Conventional Colonoscopy-Experience from Two European Centres with A Comprehensive Review of the Literature. J Clin Med 2020; 9:jcm9092981. [PMID: 32942749 PMCID: PMC7564861 DOI: 10.3390/jcm9092981] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 09/03/2020] [Accepted: 09/11/2020] [Indexed: 12/22/2022] [Imported: 08/29/2023] Open
Abstract
Background: Conventional colonoscopy (CC) allows access for colonic investigation and intervention; in the small group in whom CC is unsuccessful alternative imaging is often sufficient. There remains a subset, however, requiring full colonic visualisation or intervention. Balloon-assisted colonoscopy (BAC) gives a further option when access is difficult. Aims: This study aims to present the experience with BAC of two European tertiary referral centres. Methods: Procedures were carried out under local protocol over 15-years (2006–2020). Markers of procedural quality such as caecal intubation, complications and comfort were retrospectively compiled and analysed. Published evidence was summarised for comparison. Results: 122 procedures were undertaken, with polyps the most frequent indication and 90.2% having at least one previously incomplete CC. Features associated with difficult colonoscopy were common, including intraabdominal surgery (32.0%). 92.6% reached the caecum; completion was higher (96.3%) in those failing CC due to discomfort and lower in those failing due to anatomical difficulties (90.7%) or previous surgery (84.6%). Mean time to the caecum was 20.9 minutes and mean midazolam and fentanyl doses were 2.6 mg and 49.9 µg with low discomfort scores. Conclusion(s): Balloon-assisted colonoscopy is successful in >90% of patients, is well-tolerated, and is safe.
Collapse
|
8
|
Ciuti G, Skonieczna-Żydecka K, Marlicz W, Iacovacci V, Liu H, Stoyanov D, Arezzo A, Chiurazzi M, Toth E, Thorlacius H, Dario P, Koulaouzidis A. Frontiers of Robotic Colonoscopy: A Comprehensive Review of Robotic Colonoscopes and Technologies. J Clin Med 2020; 9:E1648. [PMID: 32486374 PMCID: PMC7356873 DOI: 10.3390/jcm9061648] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 05/16/2020] [Accepted: 05/19/2020] [Indexed: 12/15/2022] [Imported: 08/29/2023] Open
Abstract
Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold standard of all population-based screening pathways around the world. Almost 60% of CRC deaths could be prevented with screening. However, colonoscopy attendance rates are affected by discomfort, fear of pain and embarrassment or loss of control during the procedure. Moreover, the emergence and global thread of new communicable diseases might seriously affect the functioning of contemporary centres performing gastrointestinal endoscopy. Innovative solutions are needed: artificial intelligence (AI) and physical robotics will drastically contribute for the future of the healthcare services. The translation of robotic technologies from traditional surgery to minimally invasive endoscopic interventions is an emerging field, mainly challenged by the tough requirements for miniaturization. Pioneering approaches for robotic colonoscopy have been reported in the nineties, with the appearance of inchworm-like devices. Since then, robotic colonoscopes with assistive functionalities have become commercially available. Research prototypes promise enhanced accessibility and flexibility for future therapeutic interventions, even via autonomous or robotic-assisted agents, such as robotic capsules. Furthermore, the pairing of such endoscopic systems with AI-enabled image analysis and recognition methods promises enhanced diagnostic yield. By assembling a multidisciplinary team of engineers and endoscopists, the paper aims to provide a contemporary and highly-pictorial critical review for robotic colonoscopes, hence providing clinicians and researchers with a glimpse of the major changes and challenges that lie ahead.
Collapse
|
9
|
Larsson JK, Dabos KJ, Höglund P, Bohr J, Münch A, Giannakou A, Nemeth A, Wurm-Johansson G, Toth E, Plevris JN, Fineron P, Koulaouzidis A, Sjöberg K. Cancer Risk in Collagenous Colitis. J Clin Med 2019; 8:jcm8111942. [PMID: 31718057 PMCID: PMC6912303 DOI: 10.3390/jcm8111942] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Revised: 10/25/2019] [Accepted: 11/07/2019] [Indexed: 12/18/2022] [Imported: 08/29/2023] Open
Abstract
Data on malignancy in patients with collagenous colitis (CC) is scarce. We aimed to determine the incidence of cancers in patients with CC. In a two-stages, observational study, data on cancers in patients diagnosed with CC during 2000-2015, were collected from two cohorts. The risk was calculated according to the age-standardized rate for the first cohort and according to the standardized incidence ratio for the second cohort. The first cohort comprised 738 patients (394 from Scotland and 344 from Sweden; mean age 71 ± 11 and 66 ± 13 years, respectively). The incidence rates for lung cancer (RR 3.9, p = 0.001), bladder cancer (RR 9.2, p = 0.019), and non-melanoma skin cancer (NMSC) (RR 15, p = 0.001) were increased. As the majority of NMSC cases (15/16) came from Sweden, a second Swedish cohort, comprising 1141 patients (863 women, mean age 65 years, range 20-95 years) was collected. There were 93 cancer cases (besides NMSC). The risk for colon cancer was decreased (SIR 0.23, p= 0.0087). The risk for cutaneous squamous cell carcinoma was instead markedly increased (SIR 3.27, p = 0.001).
Collapse
|
10
|
Thorlacius H, Jerkeman A, Marginean FE, Toth E. Colorectal malakoplakia in a patient with hypogammaglobulinemia. Gastrointest Endosc 2018; 88:563-565. [PMID: 29627491 DOI: 10.1016/j.gie.2018.04.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2018] [Accepted: 04/02/2018] [Indexed: 02/08/2023] [Imported: 08/29/2023]
|
11
|
Nemeth A, Agardh D, Wurm Johansson G, Thorlacius H, Toth E. Video capsule endoscopy in pediatric patients with Crohn's disease: a single-center experience of 180 procedures. Therap Adv Gastroenterol 2018; 11:1756284818758929. [PMID: 29531578 PMCID: PMC5843093 DOI: 10.1177/1756284818758929] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] [Imported: 08/29/2023] Open
Abstract
BACKGROUND Video capsule endoscopy (VCE) is a noninvasive method enabling excellent visualization of the small bowel (SB) mucosa. The aim of this study was to examine the impact and safety of VCE performed in children and adolescents with suspected or established Crohn's disease (CD). METHODS A total of 180 VCE examinations in 169 consecutive patients conducted in 2003-14 in a single center were retrospectively analyzed. The median age was 13 years (range 3-17 years) and indications for VCE were suspected (125 cases, 69%) and established (55 cases, 31%) CD. VCE was performed with a PillCam SB (Given Imaging, Yokneam, Israel) VCE system with 8-12 h of registration without bowel preparation. RESULTS A total of 154 of 180 (86%) patients swallowed the capsule and 26 (14%) had the capsule endoscopically placed in the duodenum. Patency capsule examination was performed in 71 cases prior to VCE to exclude SB obstruction. VCE detected findings consistent with SB CD in 71 (40%) examinations and 17 (9%) procedures showed minor changes not diagnostic for CD. A total of 92 (51%) examinations displayed normal SB mucosa. The capsule did not reach the colon within the recording time in 30 (17%) procedures and were defined as incomplete examinations. A change in diagnosis or therapy was recommended in 56 (31%) patients based on VCE results. Capsule retention occurred in one patient. CONCLUSIONS VCE is a safe method in children with suspected or established CD. VCE often leads to a definitive diagnosis and has a significant impact on the clinical management of pediatric patients with CD.
Collapse
|
12
|
Linninge C, Roth B, Erlanson-Albertsson C, Molin G, Toth E, Ohlsson B. Abundance of Enterobacteriaceae in the colon mucosa in diverticular disease. World J Gastrointest Pathophysiol 2018; 9:18-27. [PMID: 29487763 PMCID: PMC5823699 DOI: 10.4291/wjgp.v9.i1.18] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Revised: 10/17/2017] [Accepted: 12/07/2017] [Indexed: 02/06/2023] [Imported: 08/29/2023] Open
Abstract
AIM To compare gut bacterial diversity and amount of Enterobacteriaceae in colonic mucosa between patients with and without diverticular disease (DD).
METHODS Patients in a stable clinical condition with planned elective colonoscopy were included. Blood samples and colon mucosa biopsies were collected at the colonoscopy. Study questionnaires including questions about gastrointestinal symptoms were completed by the patients and physicians. DNA from mucosa samples was isolated and the amount of Enterobacteriaceae was estimated using PCR assay. Terminal restriction fragment length polymorphism was applied to assess microbial diversity. Diversity was estimated by calculations of richness (number of terminal restriction fragments) and Shannon-Wiener and Simpson’s indices.
RESULTS A total of 51 patients were included, 16 patients with DD [68 (62-76) years] and 35 controls [62 (40-74) years] without any diverticula. Patients with DD had significantly higher levels of Enterobacteriaceae than those without DD (P = 0.043), and there was an inverse relationship between the amount of Enterobacteriaceae and the Simpson’s index (rs = -0.361, P = 0.033) and the Shannon-Wiener index (rs = -0.299, P = 0.081). The Simpson’s index (P = 0.383), Shannon-Wiener index (P = 0.401) or number of restrictions fragments (P = 0.776) did not differ between DD and controls. The majority of patients experienced gastrointestinal symptoms, and 22 patients (43.1%) fulfilled the criteria for irritable bowel syndrome, with no difference between the groups (P = 0.212). Demography, socioeconomic status, lifestyle habits, inflammatory biomarkers, or symptoms were not related to the amount of Enterobacteriaceae or bacterial diversity.
CONCLUSION Patients with DD had higher amount of Enterobacteriaceae in the colon mucosa compared to patients without diverticula.
Collapse
|
13
|
Toth E, Marthinsen L, Bergström M, Park PO, Månsson P, Nemeth A, Johansson GW, Thorlacius H. Colonic obstruction caused by video capsule entrapment in a metal stent. ANNALS OF TRANSLATIONAL MEDICINE 2017; 5:199. [PMID: 28567379 DOI: 10.21037/atm.2017.03.79] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] [Imported: 08/29/2023]
Abstract
Video capsule endoscopy (VCE) has become the method of choice for visualizing the small bowel mucosa and is generally considered to be a safe method. Although uncommon, the most feared complication of VCE is capsule retention that can potentially lead to life-threatening bowel obstruction. Herein, we present for the first time a case of capsule retention in a colonic stent. The patient had known Crohn's disease with colonic involvement and underwent an uneventful but incomplete small bowel VCE for assessment of disease activity and extension for optimizing medical treatment. Five months later, the patient presented with intestinal obstruction due to a Crohn's-stricture in the sigmoid colon, which was successfully decompressed with a self-expandable metal stent. Nonetheless, two days later the patient showed signs of bowel obstruction again and abdominal X-ray showed that the capsule was trapped in the metal stent in the sigmoid colon. Subsequently, emergency surgery was performed and the patient fully recovered. Intestinal capsule retention necessitating interventional removal is rare. This report describes a unique case of capsule retention in a colonic metal stent and highlights the potential risk of performing capsule endoscopy examinations in patients with gastrointestinal stents.
Collapse
|
14
|
Toth E, Yung DE, Nemeth A, Wurm Johansson G, Thorlacius H, Koulaouzidis A. Video capsule colonoscopy in routine clinical practice. ANNALS OF TRANSLATIONAL MEDICINE 2017; 5:195. [PMID: 28567375 DOI: 10.21037/atm.2017.03.91] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] [Imported: 08/29/2023]
Abstract
BACKGROUND Colon capsule endoscopy (CCE) offers direct mucosal visualisation without sedation or gas insufflation required in conventional colonoscopy (CC). However, evidence for the role of CCE as an adjunct or alternative to CC remains equivocal. In this observational cohort study, we report our experience of using CCE to investigate patients with suspected colon pathology at a tertiary referral centre. METHODS From 2007-2015, consecutive patients requiring colonoscopy were recruited from a tertiary care centre in Malmo, Sweden. Data collected: patient demographics, indication for CCE, findings, bowel cleansing, colon transit time (CTT) and completeness of colon examination. RESULTS Seventy-seven patients (57 F/20 F, median age 56 years) were included. The reason for CCE was previously incomplete or refused CC in 39 and 26 cases, and follow up of previous findings in 12 cases, respectively. The main clinical indications were gastrointestinal (GI) bleeding (n=28; 36%) and suspected inflammatory bowel disease (IBD) or follow-up of known IBD (n=23; 30%). CCE was complete in 58/77 (75%) patients. In 3 patients the colon was not reached; in the other 16, the capsule reached the rectum (n=4), sigmoid (n=6), descending colon (n=5) and transverse colon (n=1). Findings were: normal CCE (n=15; 19%) colonic diverticula (n=29; 38%), polyps (n=17; 22%), active IBD (n=12; 16%), haemorrhoids (n=8; 10%), colonic angioectasia (n=4; 5%) and cancer (n=1; 1%). Small-bowel findings were recorded in 8 (10%) patients. All patients tolerated bowel preparation and CCE well. Two patients with an ulcerated small-bowel stricture and cancer respectively experienced temporary capsule retention with spontaneous resolution. CONCLUSIONS CCE is a well-tolerated alternative to CC, but requires technological improvement and optimisation of clinical practice to meet current reference standards. Although further technical development is required, CCE may complement or even replace CC for certain clinical indications.
Collapse
|
15
|
Nemeth A, Wurm Johansson G, Nielsen J, Thorlacius H, Toth E. Capsule retention related to small bowel capsule endoscopy: a large European single-center 10-year clinical experience. United European Gastroenterol J 2016; 5:677-686. [PMID: 28815031 DOI: 10.1177/2050640616675219] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2016] [Accepted: 09/27/2016] [Indexed: 12/21/2022] [Imported: 08/29/2023] Open
Abstract
BACKGROUND The most concerning complication of video capsule endoscopy (VCE) is capsule retention (CR) in the gastrointestinal (GI) tract although clinical outcome and management of patients with CR are still uncertain in a large single center material. OBJECTIVES The aim of this retrospective study was to investigate incidence, causes, risk factors, management and clinical outcomes of CR in a large single center between 2001 and 2011. RESULTS 2401 consecutive small-bowel (SB) VCEs were performed. CR was detected in 25 cases (1%). CR in patients with suspected and known Crohn's disease (CD) undergoing VCE occurred in 14/1370 (1%) including known CD 9/390 (2.3%) and suspected CD 5/980 (0.5%). CR in patients with obscure GI bleeding was observed in 11/816 (1.3%) cases. The SB was the most common site of CR with 17 cases followed by the esophagus (4 cases), colon (2 cases), and stomach (2 cases). Emergency endoscopic intervention (3 cases) and surgery (2 cases) was needed in 5 cases of CR. Elective capsule removal was performed by surgery in 6 cases and endoscopically in 8 cases. Three retained capsules dislodged after steroid treatment and another 3 cases of CR resolved without any intervention. CONCLUSION This large clinical material demonstrates that CR is a rare complication with a favorable clinical outcome. Most patients with CR can be electively managed with non-surgical intervention.
Collapse
|
16
|
Boström M, Thorsson O, Toth E, Agardh D. Clinical value of wireless pH-monitoring of gastro-esophageal reflux in children before and after proton pump inhibitors. BMC Gastroenterol 2014; 14:3. [PMID: 25539736 PMCID: PMC4299672 DOI: 10.1186/s12876-014-0225-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Accepted: 12/17/2014] [Indexed: 02/08/2023] [Imported: 08/29/2023] Open
Abstract
Background Wireless pH-monitoring is an accurate method for diagnosing adults with gastroesophageal reflux disease (GERD). The aim of this study was to evaluate the use of the Bravo capsule on children investigated for GERD in terms of safety, tolerability and feasibility before and after administration of proton pump inhibitors. Methods A Bravo capsule was inserted during upper endoscopy under general anaesthesia or deep sedation with propofol. 48-hour pH-metry was performed in 106 children (50 males, 56 females) at the median age of 11 years (range 17 months-18 years). On the second day of investigation, proton pump inhibitor (PPI) was given at a mean dose of 1.6 mg/kg (SD ±0.6 mg). The definition of GERD was set to a reflux index (RI) of ≥5% and DeMeester score (DMS) ≥14.7. Results Application of the capsule was successful in 103 of the 106 children (97.2%) and interpretable in 99 of these 103 (96.1%). 49 of the children with interpretable results (49.5%) had GERD according to RI, while 51 (56.7%) had GERD according to DMS. After PPI was given on day 2, RI decreased from a median of 4.9% (range 0.3-63.4%) to 2.2% (0–58.0%), while DMS decreased from a median of 17.6 (range 2.2-207.6) to 8.2 (0.3-178.6), respectively (p < 0.0001). No severe adverse events were reported. Conclusion Wireless pH-metry is a safe and tolerable method when investigating children for GERD. PPI given on the second day of assessment provides additional information on response to treatment suggesting that pH-metry preferably should be extended to 48 hours.
Collapse
|
17
|
Toth E, Nielsen J, Nemeth A, Wurm Johansson G, Syk I, Mangell P, Almqvist P, Thorlacius H. Treatment of a benign colorectal anastomotic stricture with a biodegradable stent. Endoscopy 2011; 43 Suppl 2 UCTN:E252-3. [PMID: 21837599 DOI: 10.1055/s-0030-1256511] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] [Imported: 08/29/2023]
|
18
|
Toth E, Arvidsson S, Thorlacius H. Endoscopic reduction of a jejunogastric intussusception. Endoscopy 2011; 43 Suppl 2 UCTN:E63. [PMID: 21287456 DOI: 10.1055/s-0030-1256103] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022] [Imported: 08/29/2023]
|
19
|
Toth E, Ohlsson B, Ljungberg O, Thorlacius H. Celiac disease diagnosed using video capsule endoscopy in a patient with Crohn's disease. Endoscopy 2006; 38:548. [PMID: 16767604 DOI: 10.1055/s-2006-925342] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] [Imported: 08/29/2023]
|
20
|
Toth E, Lillienau J, Ekelund M, Alumets J, Olsson R, Thorlacius H. Ulcerated small-intestine duplication cyst: an unusual source of GI bleeding revealed by wireless capsule endoscopy. Gastrointest Endosc 2006; 63:192-4. [PMID: 16377351 DOI: 10.1016/j.gie.2005.07.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2005] [Accepted: 07/08/2005] [Indexed: 12/10/2022] [Imported: 08/29/2023]
|