1
|
Dong Y, Guggisberg E, Wang WP, Zadeh ES, Görg C, Möller K, Berzigotti A, Chaubal N, Cui XW, De Molo C, Dirks K, Montagut NE, Gilja OH, Hollerweger A, Jenssen C, Jung EM, Klinger C, Lim A, Sansone V, Schuler A, Serra C, Sparchez Z, Srivastava D, Dietrich CF. Comments and illustrations of the WFUMB CEUS liver guidelines: Rare benign focal liver lesion, part II. MEDICAL ULTRASONOGRAPHY 2024; 26:168-177. [PMID: 37632825 DOI: 10.11152/mu-4261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/28/2023]
Abstract
It is important to be familiar with the typical imaging features of the uncommon or even extremely rare focal liver lesions (FLL). Current guidelines of the World Federation for Ultrasound in Medicine and Biology (WFUMB) is aimed at assessing the usefulness of contrast enhanced ultrasound (CEUS) in the management of various FLL. In this review, we aim to summarize the ultrasound and CEUS characteristics with literature review of some extremely rare benign FLL, which might be helpful for improving diagnostic efficiency clinically.
Collapse
|
2
|
Luderer V, Jung F, Brandenstein M, Stroszczynski C, Jung EM. First assessment of flow phenomena of acute and chronic thrombosis in the jugular veins using new ultrasound vector-flow imaging. Clin Hemorheol Microcirc 2024; 86:133-142. [PMID: 37742633 DOI: 10.3233/ch-238117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/26/2023]
Abstract
AIM First assessment of flow changes in the jugular veins using high resolution ultrasound vector flow. MATERIAL UND METHODS 15 patients (8 males, 7 females) with an age range of 35 to 82 years (mean age 58.53±12.26 years) were examined by an experienced examiner using high power ultrasound equipment (Resona R9, Mindray) with probe technology (Mindray L9-3U Linear Array transducer, 2.5 to 9.0 MHz). This group was compared with five healthy subjects (mean age 35.4±13.79 years) as a reference. To assess flow changes, the color-coded duplex sonography and the novel vector flow technique were used. The evaluation was performed of vector morphology changes, turbulence, and wall resistance measurements. RESULTS There were changes after acute and chronic thrombosis in 9 cases, and venous compression in 7 cases. Turbulence was measurable from 0.01 % to 64.44 %, the average turbulence was 19.73±22.06 %. Wall resistance measurement showed values from 0.01 Pa to 3.14 Pa, depending on the age of the thrombosis or compression. The reference veins showed turbulence of 0.94±1.5 % and a mean wall resistance of 0.05±0.05 Pa. There are statistically significant differences between normal and thrombotic or compressed veins in terms of maximum wall stress (p = 0.006) and mean degree of turbulence (p = 0.012), while the difference in mean wall stress is not statistically significant (p = 0.058). CONCLUSION Despite still existing technical limitations, the combination of V-flow and wall stress measurements in jugular vein changes suggests a high diagnostic potential.
Collapse
|
3
|
Huang YL, Tian XF, Qiu YJ, Lou WH, Jung EM, Dong Y, Wang HZ, Wang WP. Preoperative ultrasound radiomics for predicting clinically relevant postoperative pancreatic fistula after pancreatectomy. Clin Hemorheol Microcirc 2024; 86:313-326. [PMID: 37927251 DOI: 10.3233/ch-231955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2023]
Abstract
OBJECTIVES To evaluate the efficacy of the radiomics model based on preoperative B-mode ultrasound (BMUS) and shear wave elastography (SWE) for predicting the occurrence of clinically relevant-postoperative pancreatic fistula (CR-POPF). METHODS Patients who were scheduled to undergo pancreatectomy were prospectively enrolled and received ultrasound assessment within one week before surgery. The risk factors of POPF (grades B and grades C) were analyzed. Preoperative BMUS images, SWE values of pancreatic lesions and surrounding parenchyma were used to build preoperative prediction radiomics models. Radiomic signatures were extracted and constructed using a minimal Redundancy Maximal Relevance (mRMR) algorithm and an L1 penalized logistic regression. A combined model was built using multivariate regression which incorporated radiomics signatures and clinical data. RESULTS From January 2020 to November 2021, a total of 147 patients (85 distal pancreatectomies and 62 pancreaticoduodenectomies) were enrolled. During the three-week follow-up after pancreatectomy, the incidence rates of grade B/C POPF were 28.6% (42/147). Radiomic signatures constructed from BMUS of pancreas parenchymal regions (panRS) achieved an area under the receiver operating characteristic curve (AUC) of 0.75, accuracy of 68.7%, sensitivity of 85.7 %, and specificity of 61.9 % in preoperative noninvasive prediction of CR-POPF. The AUC of the radiomics model increased to 0.81 when panRS was used for the prediction of CR-POPF after pancreaticoduodenectomy. CONCLUSIONS Radiomics model based on ultrasound images was potentially useful for predicting CR-POPF. Patients with high-risk factors should be closely monitored when postoperation.
Collapse
|
4
|
Zadeh ES, Schreiber N, Görg C, Huber KP, Möller K, Berzigotti A, Thomsen T, Jenssen C, Jung EM, Lim A, Kitano M, Shimizu R, Dong Y, Cui XW, Srivastava D, Dietrich CF. Comments on and illustrations of the WFUMB CEUS liver guidelines: Rare malignant mesenchymal liver lesions. MEDICAL ULTRASONOGRAPHY 2023. [PMID: 38150699 DOI: 10.11152/mu-4302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2023]
Abstract
The diagnosis or rare mesenchymal malignant lesions of the liver may be a challenge owing to the rarity of the disease and is usually made by histological confirmation. An ultrasound examination with, if required, color Doppler sonography and contrast-enhanced ultrasound, taking into account the clinical background of the patient, may help to focus the differential diagnosis. In this review, we describe the pathological and ultrasound features of several rare mesenchymal malignant liver lesions which include undifferentiated sarcoma of the liver, leiomyosarcoma, angiosarcoma, fibrosarcoma, liposarcoma, and epithelioid hemangioendothelioma.
Collapse
|
5
|
Kehrer A, Ruewe M, Klebuc M, Platz Batista da Silva N, Lonic D, Heidkrueger P, Knoedler S, Jung EM, Prantl L, Knoedler L. Objectifying the Role of the Depressor Anguli Oris Muscle Using High-Resolution Ultrasound: A Prospective Study. Plast Reconstr Surg 2023; 152:866-870. [PMID: 36780356 DOI: 10.1097/prs.0000000000010287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
BACKGROUND In the setting of facial palsy, synkinesis of the depressor anguli oris (DAO) muscle is a common pathology, impairing dynamic and resting facial symmetry.In this prospective study, the authors used high-resolution ultrasound (HRUS) to evaluate the morphologic features of DAO and to quantify bilateral differences in DAO cross-sectional diameter (CSD) in individuals with unilateral synkinesis. METHODS From June of 2020 to May of 2021, 30 patients (19 women, 11 men) with clinically diagnosed unilateral synkinesis underwent evaluation with HRUS. DAO CSD was measured bilaterally, 1 cm inferior to the modiolus, in both the resting and smiling positions. RESULTS The Sunnybrook Facial Grading System Synkinesis Score was 6.20 ± 2.48 (range, 0 to 10). DAO CSD at rest measured 2.41 ± 0.67 mm (range, 1.40 to 4.00 mm) on the control side and 2.66 ± 0.98 mm (range, 1.60 to 5.10 mm) on the affected side. On the control side, DAO CSD was reduced by -0.19 ± 0.43 mm (range, -1.10 to 1.12 mm) during smiling. In contrast, the synkinetic DAO CSD increased by 0.64 ± 0.38 mm (range, 0.00 to 1.59 mm) ( P < 0.001) with animation. The pattern of increased CSD in synkinetic DAO muscles and decreased or unchanged CSD on the control side during smiling was identified in 70% of patients. CONCLUSIONS HRUS demonstrates increased CSD in synkinetic DAO muscles during active smiling. The opposite is true for DAO muscles on the control side, which exhibit decreased CSD with animation. HRUS can be performed preoperatively to objectify DAO dysfunction and guide targeted therapy. CLINICAL QUESTION/LEVEL OF EVIDENCE Diagnostic, IV.
Collapse
|
6
|
Schauer MI, Jung EM, Platz Batista da Silva N, Akers M, Loch E, Markowiak T, Piler T, Larisch C, Neu R, Stroszczynski C, Hofmann HS, Ried M. Intraoperative Contrast-Enhanced Ultrasonography (Io-CEUS) in Minimally Invasive Thoracic Surgery for Characterization of Pulmonary Tumours: A Clinical Feasibility Study. Cancers (Basel) 2023; 15:3854. [PMID: 37568670 PMCID: PMC10417103 DOI: 10.3390/cancers15153854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 07/19/2023] [Accepted: 07/27/2023] [Indexed: 08/13/2023] Open
Abstract
BACKGROUND The intraoperative detection of solitary pulmonary nodules (SPNs) continues to be a major challenge, especially in minimally invasive video-assisted thoracic surgery (VATS). The location, size, and intraoperative frozen section result of SPNs are decisive regarding the extent of lung resection. This feasibility study investigates the technical applicability of intraoperative contrast-enhanced ultrasonography (Io-CEUS) in minimally invasive thoracic surgery. METHODS In this prospective, monocentric clinical feasibility study, n = 30 patients who underwent Io-CEUS during elective minimally invasive lung resection for SPNs between October 2021 and February 2023. The primary endpoint was the technical feasibility of Io-CEUS during VATS. Secondary endpoints were defined as the detection and characterization of SPNs. RESULTS In all patients (female, n = 13; mean age, 63 ± 8.6 years) Io-CEUS could be performed without problems during VATS. All SPNs were detected by Io-CEUS (100%). SPNs had a mean size of 2.2 cm (0.5-4.5 cm) and a mean distance to the lung surface of 2.0 cm (0-6.4 cm). B-mode, colour-coded Doppler sonography, and contrast-enhanced ultrasound were used to characterize all tumours intraoperatively. Significant differences were found, especially in vascularization as well as in contrast agent behaviour, depending on the tumour entity. After successful lung resection, a pathologic examination confirmed the presence of lung carcinomas (n = 17), lung metastases (n = 10), and benign lung tumours (n = 3). CONCLUSIONS The technical feasibility of Io-CEUS was confirmed in VATS before resection regarding the detection of suspicious SPNs. In particular, the use of Doppler sonography and contrast agent kinetics revealed intraoperative specific aspects depending on the tumour entity. Further studies on Io-CEUS and the application of an endoscopic probe for VATS will follow.
Collapse
|
7
|
Dong Y, Wang WP, Zadeh ES, Möller K, Görg C, Berzigotti A, Chaubal N, Cui XW, De Molo C, Dirks K, Montagut NE, Gilja OH, Hollerweger A, Jenssen C, Jung EM, Klinger C, Lim A, Sansone V, Schuler A, Serra C, Sparchez Z, Dietrich CF. Comments and illustrations of the WFUMB CEUS liver guidelines: Rare benign focal liver lesion, part I. MEDICAL ULTRASONOGRAPHY 2023. [PMID: 37632826 DOI: 10.11152/mu-4260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/28/2023]
Abstract
Improved detection and characterization of common focal liver lesions (FLL) are the main topics of the World Federation for Ultrasound in Medicine and Biology (WFUMB) guidelines on the use of contrast-enhanced ultrasound (CEUS). On stateof-the-art CEUS imaging, to create a library of rare FLL, especially concerning their atypical imaging characteristics, might be helpful for improving clinical diagnostic efficiency. In this review, we aim to summarize the ultrasound and CEUS features of rare benign FLL. Currently there are limited reports and images published.
Collapse
|
8
|
Rink M, Jung EM, Künzel J. The Use of Contrast-Enhanced Sonography for Therapy Monitoring of Metastatic Lymph Nodes: A Systematic Review. Curr Oncol 2023; 30:6734-6743. [PMID: 37504354 PMCID: PMC10378161 DOI: 10.3390/curroncol30070494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 07/06/2023] [Accepted: 07/13/2023] [Indexed: 07/29/2023] Open
Abstract
Metastatic cervical lymph nodes are a frequent finding in head and neck squamous cell carcinoma (HNSCC). If a non-surgical approach is primarily chosen, a therapy response evaluation of the primary tumor and the affected lymph nodes is necessary in the follow-up. Supplementary contrast-enhanced ultrasound (CEUS) can be used to precisely visualize the microcirculation of the target lesion in the neck, whereby malignant and benign findings differ in their uptake behavior. The same applies to many other solid tumors. For various tumor entities, it has already been shown that therapy monitoring is possible through regular contrast-enhanced sonography of the primary tumor or the affected lymph nodes. Thus, in some cases, maybe in the future, a change in therapy strategy can be achieved at an early stage in the case of non-response or, in the case of therapy success, a de-escalation of subsequent (surgical) measures can be achieved. In this paper, a systematic review of the available studies and a discussion of the potential of therapy monitoring by means of CEUS in HNSCC are presented.
Collapse
|
9
|
Rink M, Krassler J, Symeou L, Fischer R, Jung EM, Künzel J. [Use of Contrast enhanced Ultrasound (CEUS) in the Head and Neck Area: Update]. Laryngorhinootologie 2023; 102:450-463. [PMID: 37267968 DOI: 10.1055/a-1994-5141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
With the help of contrast enhanced ultrasound, the diagnostic accuracy of conventional sonography can be increased in many areas of otorhinolaryngology. Vascularisation and tissue perfusion can be objectified through the examination. This offers promising approaches for example to monitor the therapy of metastatic cervical lymph nodes or in the treatment of vascular malformations. Contrast Enhanced Ultrasound (CEUS) also offers great potential for differential diagnosis, for example of thyroid nodules. Valid threshold values for the quantitative time intensity curve (TIC) analysis of cervical pathologies are currently still not available. Further studies are necessary. As there is currently no license for the use of contrast enhanced ultrasound in otorhinolaryngology patients must be informed about its off-label use before the examination. This article is intended to provide an overview of the current possibilities and to serve as an introduction to the topic.
Collapse
|
10
|
Jung EM, Stroszczynski C, Jung F. Advanced multimodal imaging of solid thyroid lesions with artificial intelligence-optimized B-mode, elastography, and contrast-enhanced ultrasonography parametric and with perfusion imaging: Initial results. Clin Hemorheol Microcirc 2023:CH239102. [PMID: 37092219 PMCID: PMC10357218 DOI: 10.3233/ch-239102] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
Goal of the study was the assessment of AI-assisted diagnosis of solid thyroid foci with multimodal modern ultrasound imaging. 50 patients (26-81 years, 54.7±13.1 years) were included in the study. Multimodal ultrasound imaging by means of B-mode with linear probe (4-12 MHz) with option of automated documentation of findings by means of AI, with supplementary Ultra MicroAngiography (UMA) was used. Macrovascularisation was assessed by dynamic contrast ultrasonography (CEUS) with parametric evaluation and perfusion analysis, and microvascularization was assessed by combined strain and shear wave elastography on a novel high-performance ultrasound system (Resono R9/Mindray) by an experienced examiner with independent reading. The evaluation was performed according to TI-RADS III-V.The volume of the thyroid lobes on both sides averaged 39 ml±5 ml (27 to 69 ml). The 13 cases of histologically confirmed thyroid carcinomas (8 papillary, 2 medullary, 2 microfollicular, 1 anaplastic CA) with a mean size of 15 mm±6 mm (9-21 mm) were correctly evaluated by TI-RADS V on the basis of irregular shape, induration > 2.5 m or > 30kPA and striking wash-out kinetics. Tumor lymph nodes could only be correctly detected preoperatively in one case of medullary carcinoma according to the surgical findings, based on irregular vascularization with UMA in roundish shape with cortex > 4 mm, transverse diameter up to 11 mm. In 25 cases of inhomogeneous nodular goiter an evaluation with TI-RADS III was performed in 31 cases, in 4 cases with incomplete marginal contour, partial marginal vascularization with UMA and partial wash out with indurations up to 2.5 m/s 30 kPA an evaluation with TI-RADS IV and surgical excision for nodular goiter. In 12 cases regressive nodular changes without relevant malignancy criteria resulted in nodular goiter, with focal changes up to 1.5 cm in diameter, classified as requiring control with TI-RADS III. There were no relevant changes in findings in the controls after 6 months. From the AI tool, the 20/25 goiter nodes were assessed as TI-RADS III, 7/12 adenomas, 5 goiter nodes, and 5 adenomas as TI-RADS IV, 5/13 carcinomas as TI-RADS IV, and 8/13 carcinomas as TI-RADS V.Multimodal ultrasound diagnostics supported by AI has a high diagnostic potential for the evaluation of solid thyroid lesions and standardizes the reporting with digital representative image documentation. CEUS perfusion and modern elastography techniques allow targeted follow-up of TI-RADS III findings.
Collapse
|
11
|
Huang Y, Wang Y, Liu L, Zhu L, Qiu Y, Zuo D, Lu X, Dong Y, Jung EM, Wang W. VueBox® perfusion analysis of dynamic contrast enhanced ultrasound provides added value in the diagnosis of small thyroid nodules. Clin Hemorheol Microcirc 2023; 83:409-420. [PMID: 36683500 DOI: 10.3233/ch-221681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
OBJECTIVES To explore the potential added value of dynamic contrast enhanced ultrasound (DCE-US) using VueBox® software for the diagnosis of small solid thyroid nodules (≤1.0 cm). PATIENTS AND METHODS This prospective study was approved by the institutional review board and it was performed at two hospitals from January 2020 to October 2020. B mode ultrasound and contrast enhanced ultrasound (CEUS) images were obtained for 79 small solid thyroid nodules (≤1.0 cm) confirmed by ultrasound-guided fine needle aspiration cytology results in 79 consecutive patients (55 women and 24 men, median age: 41 years). The CEUS time-intensity curves (TICs) of thyroid nodules and surrounding parenchyma were created by VueBox® software (Bracco, Italy). The CEUS quantitative parameters were obtained after curve fitting. The diagnostic efficiency of the diagnostic performance of CEUS and DCE-US was evaluated and compared. The weighted kappa statistic (κ) was performed to assess the interobserver agreement and consistency between the diagnosis of CEUS and DCE-US. RESULTS Among the 79 thyroid nodules, 56 (70.9 %) were malignant and 23 (29.1 %) were benign lesions. Hypoenhancement during the arterial phase of CEUS was associated with malignancy (P < 0.001), with an AUC of 0.705 (sensitivity 71.4 %, specificity 69.6 %). Among all CEUS quantitative parameters, the peak enhancement (PE), wash-in rate (WiR), and wash-out rate (WoR) of DCE-US in malignancies were significantly lower than those in benign nodules (P = 0.049, P = 0.046, and P = 0.020, respectively). The AUCs of PE, WiR, and WoR were 0.642 (sensitivity 65.2 %, specificity 67.9 %), 0.643 (sensitivity 43.5 %, specificity 91.1 %), and 0.667 (sensitivity 69.6 %, specificity 69.6 %) in differentiation between benign and malignant small solid thyroid nodules (≤1.0 cm), respectively. Comparing the quantitative parameters of DCE-US between small solid thyroid nodules and surrounding normal thyroid parenchyma, the PE, WiAUC, WiR, WiPI, WoAUC, WiWoAUC, and WoR of the nodules were significantly lower than those of normal thyroid tissue (P = 0.008, P < 0.001, P = 0.037, P = 0.009, P = 0.003, P = 0.002, P = 0.049, respectively). A total of 16 (20.3 %) nodules showed isoenhancement during the arterial phase of CEUS, while the median PE ratio of surrounding tissue and thyroid nodules was 1.70 (IQR: 1.33-1.89). CONCLUSIONS VueBox® is a helpful tool for the evaluation of dynamic microvascularization of thyroid nodules, and DCE-US using VueBox® perfusion analysis could provide added values for differential diagnosis of small solid thyroid nodules (≤1.0 cm).
Collapse
|
12
|
Schleder S, Jung EM, Schicho A, Schreyer AG, Habicher W, Grassinger J, Dollinger M. Efficacy and safety of ultrasound-guided core needle biopsies (US-CNBs) in cervical lymphadenopathy in patients with suspected head and neck cancer during the COVID-19 pandemic. Clin Hemorheol Microcirc 2023; 83:397-408. [PMID: 36683499 DOI: 10.3233/ch-221680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
BACKGROUND Cervical lymphadenopathy can be benign or malignant. Its accurate diagnosis is necessary to determine appropriate treatment. Ultrasound-guided core needle biopsies (US-CNBs) are frequently used as a percutaneous sampling approach. OBJECTIVES Our aim was to identify the efficacy and safety of US-CNBs in 125 patients with cervical lymphadenopathy and clinically suspected head and neck cancer during the COVID-19 pandemic with limited surgical resources. METHODS US-CNBs of pathological lymph nodes were performed in 146 lymph nodes on 125 patients. Biopsies were performed ultrasound-guided with a reusable gun core biopsy system and a 10-cm-long 16-G needle. Standard of reference for the histological findings were panendoscopy, clinical and sonographic follow-up, surgical biopsy or a repeat US-CNB. RESULTS Adequate material for histologic diagnosis was obtained in 111 patients (89%), of these 83 patients (75%) were diagnosed as malignant, whereas benign lymphadenopathy accounted for 28 patients (25%). Therefore, US-CNB was able to identify malignant or benign lymphadenopathy with an overall accuracy of 88% and 90%, respectively. CONCLUSIONS Percutaneous US-CNB is a safe and effective alternative to surgical biopsy in the management of cervical lymphadenopathy in patients with clinically suspected head and neck cancer in a setting with limited resources.
Collapse
|
13
|
Rink M, Jung EM, Bohr C, Künzel J. Use of contrast-enhanced ultrasound in preoperative planning before resection of a second branchial cleft fistula. Clin Hemorheol Microcirc 2023; 85:83-86. [PMID: 37545228 DOI: 10.3233/ch-231862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
In the head and neck area, a large proportion of clinically relevant fistulas occur in childhood. The present case describes the use of contrast enhanced ultrasound with intraductal administration of the contrast medium for preoperative visualization of the fistula duct in the case of a second brachial cleft fistula. This provided the surgeon with important additional information, such as the detailed course of the fistula and its relation to the large vessels of the neck. The method can help to improve surgical planning, reduce radiation exposure and to avoid imaging under general anesthesia, especially in children.
Collapse
|
14
|
Jung EM, Dong Y, Jung F. Current aspects of multimodal ultrasound liver diagnostics using contrast-enhanced ultrasonography (CEUS), fat evaluation, fibrosis assessment, and perfusion analysis - An update. Clin Hemorheol Microcirc 2023; 83:181-193. [PMID: 36776044 PMCID: PMC9986700 DOI: 10.3233/ch-239100] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
Current ultrasound multifrequency probes allow both improved detail resolution and depth of penetration when examining the liver. Also, new developments in vascular diagnostics, elastography with fibrosis assessment, evaluation of possible steatosis, and parametric and time intensity curve (TIC) analysis of dynamic microvascularization of the liver with contrast-enhanced ultrasound sonography (CEUS) complement ultrasound-guided diagnostics. State-of-the-art high-resolution technology includes a high frame rate (HiFR) mode for CEUS, fast shear wave measurements with the sound touch quantify (STQ) mode, artifact-free flow detection using HR flow and glazing flow in combination with a special flow-adapted imaging (Ultra Micro Angiography, UMA) and additionally different assessments of possible fatty liver (UltraSound ATtenuation Imaging Technology, USAT). In 50 cases with focal liver lesions, a multimodal liver diagnosis was performed with a still new high-performance ultrasound system as part of the clarification of questions from the university liver consultation and tumor outpatient clinic.
Collapse
|
15
|
Kaiser U, Herr W, Greiner B, Stroszczynski C, Jung EM. Mobile handheld ultrasound with VScan Air for the diagnosis of deep vein thrombosis. Clin Hemorheol Microcirc 2023; 83:149-161. [PMID: 36278343 DOI: 10.3233/ch-221598] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE This study aimed to evaluate a new W-Lan-supported ultrasound mobile technology for the diagnosis of vascular peripheral thrombosis. MATERIAL AND METHODS Fifty patients were examined by an experienced reference sonographer using high-end technology and a W-Lan supported device (VScan Air) to evaluate its diagnostic capabilities for peripheral thrombosis. RESULTS Fifty patients were examined (age, 25-88 years; male, n = 27, female n = 23). Thromboses were diagnosed in the neck (n = 1), upper leg (n = 7), lower leg (n = 49), and muscle veins (n = 25). VScan Air technique also allows the diagnosis of circumscribed deep vein thrombosis with a sufficient diagnostic certainty. Moreover, for superficial thrombi that can be well-delineated, a maximum image quality is possible compared to high-end technology. CONCLUSION The mobile VScan technology opens up new possibilities for near-patient and location-independent imaging in cases of deep vein thrombosis.
Collapse
|
16
|
Jung F, Lamby P, Prantl L, Wiggermann P, Jung EM, Krüger-Genge A, Franke RP. Post-mortem distribution of Iodinated Contrast Media (ICM) (iodixanol versus iopromide) in the porcine kidney after multiple bolus injections in vivo into the supra-renal aorta1. Clin Hemorheol Microcirc 2023; 85:289-295. [PMID: 36502310 DOI: 10.3233/ch-229102] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Iodinated contrast media (ICM) are widely used for diagnostic and interventional procedures in radiology and cardiology. Ideally, they should not interact with blood cells or vascular wall cells to avoid deteriorations of the blood circulation. However, it is well known that ICM can affect erythrocytes as well as endothelial cells which consequently might perturb especially the microcirculation. In former studies the influence of two ICM (iodixanol versus iopromide) on the vascular system, the development of blood stasis, on changes in renal resistive index (RRI) and vascular diameters, and on the post-mortem distribution of iodine as marker for ICM in the explanted kidneys was examined. The modus of ICM application into the supra-renal aorta followed the regime in interventional cardiology, so that 10 bolus injections were administered at steady intervals (iopromide 4,32 ml / iodixanol 5 ml) accompanied by infusion of 500 ml isotonic NaCl-solution.In the present study, the post-mortem X-ray analysis revealed that there were no differences in iodine content in the regions of the mid-cortex and the medullo-pelvic transition zone of the kidneys after application of both ICM. Remarkable differences, however, were found in the region of the capsule-near cortex, where the application of iopromide led to a significantly lower iodine content in the microcirculation. This is in good agreement with former studies, in which a maldistribution in this area, presumably due to a decrease in arteriolar inflow as a result of stasis/occlusion was shown.
Collapse
|
17
|
Tews HC, Kandulski A, Schmid S, Schlosser S, Schirner S, Putz FJ, Cosma L, Gülow K, Müller M, Jung EM. Multimodal ultrasound imaging with conventional B-mode, elastography, and parametric analysis of contrast-enhanced ultrasound (CEUS): A novel approach to assess small bowel manifestation in severe COVID-19 disease. Clin Hemorheol Microcirc 2022; 82:341-360. [PMID: 35871323 DOI: 10.3233/ch-221540] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
The aim was to describe the small bowel morphology with conventional B-mode and elastography and additionally to evaluate dynamic effects of COVID-19 associated small bowel microvascularization using CEUS with color coded perfusion parameters.Thirteen patients with severe COVID-19 acute respiratory distress syndrome (ARDS) were investigated. 13 patients required intensive care treatment with mechanical ventilation. Five patients required extracorporeal membrane oxygenation (ECMO). Contrast-enhanced ultrasound (CEUS) was performed by an experienced investigator as a bolus injection of up to 2.4 ml sulfur hexafluoride microbubbles via a central venous catheter. In the parametric analysis of CEUS, the flare of microbubbles over time is visualized with colors. This is the first work using parametric analysis of CEUS to detect perfusion differences in the small bowel.Parametric analysis of CEUS in the intestinal phase was carried out, using DICOM loops for 20 seconds. In 5 patients, parametric analysis revealed intraindividual differences in contrast agent behavior in the small bowel region. Analogous to the computed tomography (CT) images parametric analysis showed regions of simultaneous hyper- and hypoperfusion of the small intestine in a subgroup of patients. In 5 patients, the parametric image of transmural global contrast enhancement was visualized.Our results using CEUS to investigate small bowel affection in COVID-19 suggest that in severe COVID-19 ARDS systemic inflammation and concomitant micro embolisms may lead to disruption of the epithelial barrier of the small intestine.This is the first study using parametric analysis of CEUS to evaluate the extent of small bowel involvement in severe COVID-19 disease and to detect microemboli. In summary, we show that in COVID-19 the small bowel may also be an important interaction site. This is in line with the fact that enterocytes have been shown to a plenitude of angiotensin converting enzyme (ACE)-2 receptors as entry sites of the virus.
Collapse
|
18
|
Jung EM, Jung F, Verloh N, Haimerl M, Lürken L, Jage S, Stroszczynski C, Scharf G. High resolution flow with glazing flow for optimized flow detection in transjugular intrahepatic portosystemic stent shunt (TIPS): First results. Clin Hemorheol Microcirc 2022; 82:231-238. [PMID: 35723091 DOI: 10.3233/ch-221427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND Ultrasound follow-up of transjugular intrahepatic portosystemic shunt (TIPS) is challenging due to the bent course of the stent-graft. OBJECTIVE Aim of this retrospective study was to assess to which extent the combination of HR flow with Glazing Flow improves hemodynamic assessment in the ultrasound follow-up of TIPS. METHODS Comparative studies with CCDS and High Resolution (HR)-Flow with Glazing Flow were evaluated regarding image quality and artifacts on a 5-point scale (0 = cannot be assessed up to 5 = maximum image quality without artifacts). In all cases, an experienced examiner performed the examinations with a 1-6 MHz probe (Resona 7, Mindray). RESULTS 61 ultrasound examinations in 48 patients were performed; the mean patient age was 54±14.2 years. The use of HR-Flow with Glazing Flow resulted in an improved flow display in 55/61 cases (90.2%). Both methods correlated well (r = 0.71), but HR flow with Glazing flow values were in general higher than CCDS values. The reading resulted in an average value of 2.52±0.54 for CCDS and 3.52±0.57 for HR flow with Glazing flow (p = 0.013). CONCLUSION The combination of HR-Flow and Glazing Flow results in improved flow representation and reduction of artifacts in the ultrasound follow-up of TIPS.
Collapse
|
19
|
Brandenstein M, Wiesinger I, Künzel J, Hornung M, Stroszczynski C, Jung EM. Multiparametric Sonographic Imaging of Thyroid Lesions: Chances of B-Mode, Elastography and CEUS in Relation to Preoperative Histopathology. Cancers (Basel) 2022; 14:cancers14194745. [PMID: 36230668 PMCID: PMC9564296 DOI: 10.3390/cancers14194745] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 09/21/2022] [Accepted: 09/23/2022] [Indexed: 12/03/2022] Open
Abstract
Simple Summary As the incidence of thyroid lesions in Europe is rising, more and more people affected by thyroid pathologies seek treatment in a clinic. Every suspicious thyroid nodule needs to be confirmed as benign or malignant in order to be treated correctly. Unnecessary invasive diagnostics and thyroid surgery should be avoided. The aim of this retrospective study was to improve the distinction between benign and malignant nodules by using new high-performance multiparametric ultrasound examination techniques. By analyzing 122 thyroid nodules we created a score-based system combining B-mode, shear-wave elastography and contrast-enhanced ultrasound malignancy criteria. This system allows for a quite accurate detection of thyroid carcinomas with a sensitivity of 95% and specificity of 75.49%. Shear-wave elastography and contrast-enhanced ultrasound can detect unique malignancy features, which cannot be found in B-mode. Therefore, these criteria would present a relevant addition to the B-mode TI-RADS classification. Abstract Background: The aim was to improve preoperative diagnostics of solid non-cystic thyroid lesions by using new high-performance multiparametric ultrasound examination techniques. Methods: Multiparametric ultrasound consists of B-mode, shear-wave elastography and contrast enhanced ultrasound (CEUS) including Time-Intensity-Curve (TIC) analysis. A bolus of 1–2.4 mL Sulfur Hexafluorid microbubbles was injected for CEUS. Postoperative histopathology was the diagnostic gold standard. Results: 116 patients were included in this study. 102 benign thyroid nodules were diagnosed as well as 20 carcinomas. Suspicious B-mode findings like microcalcifications, a blurry edge and no homogeneous sonomorphological structure were detected in 60, 75 and 80% of all carcinomas but only in 13.7, 36.3 and 46.1% of all benign lesions. The average shear-wave elastography measurements of malignant lesions (4.6 m/s or 69.8 kPa centrally and 4.2 m/s or 60.1 kPa marginally) exceed the values of benign nodules. Suspicious CEUS findings like a not-homogeneous wash-in and a wash-out were detected almost twice as often in carcinomas. Conclusion: Multiparametric ultrasound offers new possibilities for the preoperative distinction between benign and malignant thyroid nodules. A score based system of B-mode, shear-wave and CEUS malignancy criteria shows promising results in the detection of thyroid carcinomas. It reaches a sensitivity of 95% and specificity of 75.49%.
Collapse
|
20
|
Jung EM, Jung F, Stroszczynski C, Wiesinger I. Dynamic endoluminal contrast enhanced ultrasound (CEUS) for display of drainages in inflammatory abdominal fluid collections1. Clin Hemorheol Microcirc 2022; 80:49-59. [PMID: 35001884 DOI: 10.3233/ch-211370] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
AIM To evaluate the additive clinical value of endoluminal contrast enhanced ultrasound (CEUS) after interventional placement of drainages in abdominal fluid collections. MATERIAL/METHOD Examination of 30 patients using a 1-6 MHz convex probe (Resona 7, Mindray) to locate the fluid collection in B-Mode. Additionally, dynamic endoluminal CEUS with 1 ml sulphur-hexafluoride microbubbles was performed to measure the extent of the percutaneously drained abscesses. Independent assessment of dynamically stored images in PACS in DICOM format. Correlation to reference imaging using computed tomography (CT). RESULTS A total of 30 patients were examined (17 m, 19-78 years, mean 56.1 years). Drainages were positioned in the liver in 15 cases, in the pelvis after kidney transplantation in 4 cases, close to the spleen in 1 case and in the abdomen in 10 cases. In all cases abscesses showed marginal hyperaemia with reactive septations in CEUS. The drainage position was assessed by means of B-mode in all cases first and then by CEUS. In 4 cases CEUS showed a fistula to the pleura, in 5 cases to the peritoneum, in 2 cases to the intestine, in 5 cases to the biliary tract, corresponding to the CT. In 2 cases there was a hint of an anastomotic leakage after intestinal anastomosis, which was reliably detected by CT. The drainage was removed in 11 cases within a period of 2 to 5 days after CEUS control, in 9 cases within a period of 5 to 10 days. Another operation was necessary in 3 cases. A new drainage was placed in 2 cases. The required amount of contrast medium is 1 ml endoluminally diluted to 9 ml sodium chloride. CONCLUSION CEUS facilitates the exact localization and characterization of inflammatory abdominal fluid collections. Furthermore, possible fistulas can be detected that cannot be seen with conventional ultrasound.
Collapse
|
21
|
Diesch ST, Jung F, Prantl L, Jung EM. Surface imaging of breast implants using modern high-frequency ultrasound technology in comparison to high-end sonography with power analyses for B-scan optimization1. Clin Hemorheol Microcirc 2021; 80:487-495. [PMID: 34897080 DOI: 10.3233/ch-219204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AIM This study aims to evaluate optimized breast implant surface-structure analysis by comparing high-end ultrasound technology with a new high frequency technique. This comparative study used new breast implants with different surfaces in an in vitro setting. METHODS Nine idle silicon or polyurethane (PU) breast implants were examined by two investigators in an experimental in vitro study using two high-end ultrasound devices with multi-frequency transducers (6-15 MHz, 9-16 MHz, 12.5-33 MHz).The ultrasound B-Mode was optimized using tissue harmonic imaging (THI), speckle reduction imaging (SRI, level 0-5), cross beam (high, medium, low) and photopic.Using a standardized ultrasound protocol, the implants were examined in the middle (point of highest projection) and lateral, by two independent examiners.Image evaluation was performed on anonymized digital images in the PACS. The aim was to achieve an artifact-free recording of the surface structure, the surface coating, the total image structures and, as far as possible, an artifact-free internal representation of the implants.For independent surface evaluation a score was used (0 = undetectability of surface structures, rich in artifacts, 5 = best possible, artifact free image quality). RESULTS The quality of ultrasound imaging of breast implant surfaces after the optimization of B-Scan differed significantly comparing high-end ultrasound technology with modern high-frequency ultrasound technology (p < 0,05).The following setting has been found to be the best setting with the highest image quality:B-Mode, SRI value 3, Crossbeam high level with color coded imaging for B- mode. In the total examined frequency range of 6-33 MHz, the highest image quality was found in the average frequency range of 12.5-33 MHz at both measured points. For both devices, device 1 (high-end) and device 2 (high frequency) ultrasound, the image quality was in the12.5-33 MHz frequency range with an average image quality of 3.236. It was significantly higher, than in the lower frequency ranges and the same frequency range with THI. (p < 0,05). The image quality of the high-end sonography device was superior to the conventional high-frequency ultrasound device in all frequency ranges. CONCLUSION High-end ultrasound imaging technology was superior in the quality of implant surface evaluation in comparison to high-frequency ultrasound sonography. The gained knowledge can serve as a basis for further multicenter clinical application and studies with the aim to develop an objective, precise tool to evaluate the implant and the surrounding tissue with ultrasound.
Collapse
|
22
|
Dong Y, Koch JBH, Löwe AL, Christen M, Wang WP, Jung EM, Mohaupt MG, Dietrich CF. VueBox® for quantitative analysis of contrast-enhanced ultrasound in liver tumors. Clin Hemorheol Microcirc 2021; 80:473-486. [PMID: 34897079 DOI: 10.3233/ch-211261] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Dynamic contrast-enhanced ultrasound (DCE-US) enables quantification of tumor perfusion. VueBox is a platform independent external software using DICOM cine loops which objectively provides various DCE-US parameters of tumor vascularity. This review summaries its use for diagnosis and treatment monitoring of liver tumors. The existing literature provides evidence on the successful application of Vuebox based DCE-US for characterization and differential diagnosis of focal liver lesions, as well as on its use for monitoring of local ablative therapies and of modern systemic treatment in oncology.
Collapse
|
23
|
Abstract
In multimodal radiologic imaging, contrast-enhanced ultrasound (CEUS) is increasingly used. One of the advantages of CEUS is the possibility of repeated application of contrast media without decreasing renal function or affecting the thyroid gland. Small solid liver lesions can be diagnosed and detected with high accuracy. Moreover, solid lesions in other abdominal organs can also be characterized. Frequent applications for solid lesions in the near field concern thyroid tumors and lymph nodes. For prostate diagnostics, CEUS can be used with an endorectal probe and perfusion imaging. This review explains how the additional (semi-)quantitative perfusion analysis, especially time-intensity curve (TIC) analyses, and wash-in/wash-out kinetics of integrated or external perfusion software programs facilitate new options in dynamic assessment of microvascularization during tumor follow-up care and even minimally invasive tumor therapy.
Collapse
|
24
|
Jung EM, Kammerer S, Brandenstein M, Putz FJ, Stroszczynski C, Jung F. High resolution flow (HR Flow) and glazing flow in cases of hepatic flow changes: Comparison to color-coded Doppler sonography (CCDS). Clin Hemorheol Microcirc 2021; 79:3-17. [PMID: 34397406 PMCID: PMC8609679 DOI: 10.3233/ch-219102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
AIM To evaluate the possibilities of flow detection using high resolution flow (HR Flow) and Glazing Flow technique in patients with liver parenchymal changes and flow changes in comparison to colour coded Doppler sonography (CCDS). MATERIAL AND METHODS All examinations were performed using a multi frequency matrix convex probe with high resolution technique (SC6-1U/Resona7, Mindray, Shenzhen, China) by one experienced examiner to evaluate the venous, portal venous and arterial liver flow with digital documentation of the dynamic flow parameters like peak systolic flow, end-diastolic flow and resistance index. For liver parenchymal stiffness changes shear wave elastography was performed with at least 10 measurements. By two independent readers an elevation was performed to evaluate the image quality and the degree of flow artefacts, from 0 = not available to 5 points with excellent image quality without flow artefacts. RESULTS All 40 patients (24 men, 16 women, age 27-83 years, mean 56±5 years) showed morphology changes from B-Mode of the liver parenchyma to inhomogeneous tissue with higher stiffness evaluated by the shear wave elastography (1.45 m/s up to 2.79 m/s±1.79 m/s, considering F1 up to F4 fibrosis) and in 15 cases histopathologically proven liver cirrhosis. In 9 cases after non-acute thrombosis flow reduction of the portal vein was the reason for the diameter less than 5 mm. Flow parameters for the venous flow were between 8 cm/s up to 29 cm/s, mean 14±4 cm/s, for the hepatic portal vein 5 cm/s up to 57 cm/s, mean 17±5 cm/s, for the hepatic artery systolic flow between 50 cm/s up to 127±33 cm/s, end-diastolic flow from 22 cm/s up to 47 cm/s±8 cm/s. Resistance index for the hepatic artery was between 0.41 up to 0.73, mean 0.67±0.25. The image quality for CCDS over all cases was evaluated for CCDS between 1 up to 4. The mean quality was 2.5±0.5, for HR Flow in combination with Glazing flow 3±0.5, with significant differences for the 2 readers (P < 0.01). CONCLUSION Combination of HR Flow with Glazing Flow could be helpful to evaluate morphological und hemodynamic changes of liver arterial flow, portal venous and venous flow. Reduction of flow artefacts in combination with a higher image quality could be helpful for optimizing the digital measurements also for follow up examinations.
Collapse
|
25
|
Maxeiner A, Fischer T, Stephan C, Treskatsch S, Baur ADJ, Jung EM, Hamm B, Lerchbaumer MH. Use of TDI during MRI/US fusion-guided biopsy for suspected prostate cancer. Clin Hemorheol Microcirc 2021; 78:259-269. [PMID: 33646144 DOI: 10.3233/ch-201035] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND Tissue Doppler imaging (TDI) uses the Doppler principle to quantify the movement of biological tissues. OBJECTIVE To investigate the contribution of TDI parameters derived during magnetic resonance imaging and ultrasound (MRI/US) fusion-guided biopsy for prostate cancer (PCa) discrimination. METHODS From March 2016 to Dec. 2018, 75 men with suspected PCa prospectively underwent fusion-guided prostate biopsy. TDI overlaid on predefined target lesion were compared to the confirmed contralateral tumor-free area of the prostate gland (using Image J). Diagnostic value of TDI parameters was assessed using histopathology as standard of reference. RESULTS Thirty-seven patients were diagnosed with PCa (49.3%), among them 27 with clinically significant PCa (Gleason score > 3 + 3 = 6 (ISUP 1). The LES/REF ratio was lower in confirmed PCa patients compared to patients without PCa (0.42, IQR, 0.22-0.59 vs. 0.52, IQR, 0.40-0.72, p = 0.017). TDI parameters allowed differentiation of low-risk from high-to-intermediate-risk PCa (ISUP 2 versus ISUP 3) based on lower pixel counts within the target ROI (1340, IQR 596-2430 vs. 2687, IQR 2453-3216, p = 0.004), lower pixel percentage (16.4 IQR 11.4-29.5 vs. 27.3, IQR 22.1-39.5; p = 0.005), and lower LES/REF ratios (0.29, IQR 0.19-0.51 vs. 0.52, IQR 0.47-0.74, p = 0.001). CONCLUSION TDI of prostate lesions prelocated by MRI discriminates between cancerous and noncancerous lesions and further seems to enable characterization of PCa aggressiveness. This widely available US technique may improve confidence in target lesion localization for tissue sampling.
Collapse
|