226
|
Rodríguez-Rodríguez A, Shuvaev S, Rotile N, Jones CM, Probst CK, Dos Santos Ferreira D, Graham-O′Regan K, Boros E, Knipe RS, Griffith JW, Tager AM, Bogdanov A, Caravan P. Peroxidase Sensitive Amplifiable Probe for Molecular Magnetic Resonance Imaging of Pulmonary Inflammation. ACS Sens 2019; 4:2412-2419. [PMID: 31397156 DOI: 10.1021/acssensors.9b01010] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
An amplifiable magnetic resonance imaging (MRI) probe that combines the stability of the macrocyclic Gd-DOTAGA core with a peroxidase-reactive 5-hydroxytryptamide (5-HT) moiety is reported. The incubation of the complex under enzymatic oxidative conditions led to a 1.7-fold increase in r1 at 1.4 T that was attributed to an oligomerization of the probe upon oxidation. This probe, Gd-5-HT-DOTAGA, provided specific detection of lung inflammation by MRI in bleomycin-injured mice.
Collapse
|
227
|
Fluorescein- and EGFR-Antibody Conjugated Silica Nanoparticles for Enhancement of Real-time Tumor Border Definition Using Confocal Laser Endomicroscopy in Squamous Cell Carcinoma of the Head and Neck. NANOMATERIALS 2019; 9:nano9101378. [PMID: 31561451 PMCID: PMC6835239 DOI: 10.3390/nano9101378] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Accepted: 09/24/2019] [Indexed: 11/17/2022]
Abstract
Intraoperative definition of tumor free resection margins in head and neck cancer is challenging. In the current proof-of-principle study we evaluated a novel silica nanoparticle-based agent for its potential use as contrast enhancer. We synthesized silica nanoparticles with an average size of 45 nm and modified these particles with the fluorescence stain fluorescein isocyanate (FITC) for particle detection and with epidermal growth factor receptor (EGFR)-targeting antibodies for enhanced tumor specificity. The nanoparticles exhibited good biocompatibility and could be detected in vitro and in vivo by confocal laser scanning microscopy. Additionally, we show in an ex vivo setting that these modified nanoparticles specifically bind to tumor samples and could be detected using a handheld confocal fluorescence endomicroscope. From a clinical point of view, we believe that this method could be used for tumor border contrast enhancement and for better intraoperative definition of R-0 tumor resection.
Collapse
|
228
|
Sakurai Y, Ikeda Y. Development of a contrast-enhanced micro computed tomography protocol for the oval squid (Sepioteuthis lessoniana) brain. Microsc Res Tech 2019; 82:1941-1952. [PMID: 31411804 DOI: 10.1002/jemt.23363] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Revised: 06/28/2019] [Accepted: 08/01/2019] [Indexed: 01/13/2023]
Abstract
Coleoid cephalopods (squid, cuttlefish, and octopus) have a well-developed and complex central nervous system. Its absolute size is the largest among invertebrates, and the brain-to-body mass ratio is larger than that of fish and reptiles and equivalent to that of birds and mammals. Although a number of histological studies have been conducted on the brains of cephalopods, most of them used a light microscope or an electron microscope, which show the microstructure of the brain, but often cannot image the whole brain instantaneously. Of late, micro computed tomography (CT) has gained popularity for imaging animal brains because it allows for noninvasive three-dimensional (3D) reconstruction and preprocessing that are not cumbersome. To perform micro-CT on cephalopod brains, we first tested conditions suitable for preprocessing, paying special attention to staining conditions that would provide high contrast images. Four agents, iodine in 99.5% ethanol, iodine potassium iodide in water (IKI), phosphotungstic acid in 70% ethanol, and nonionic iodinated contrast agent in water, were tested at various concentrations and durations on brain of juvenile oval squid. To evaluate the quality of staining, we calculated the contrast ratio of the two-dimensional (2D) images and compared 3D segmentation of the best and worst 2D images. We concluded that 3% IKI staining for 7 days was the best combination to enhance the images contrast of the oval squid brain, in which each brain lobe was clearly detected and 3D segmentation of the whole brain was possible. The wider applicability of this preprocessing method for micro-CT of the brains of other cephalopods is discussed.
Collapse
|
229
|
Wen LY, Yang ZG, Li ZL, Ai H, Xia CC, Zhang LZ, Lin BB, Zhang K, Fu H, Wu CQ, Yang L, Fan HM, Guo YK. Accurate identification of myocardial viability after myocardial infarction with novel manganese chelate-based MR imaging. NMR IN BIOMEDICINE 2019; 32:e4158. [PMID: 31393647 DOI: 10.1002/nbm.4158] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 06/17/2019] [Accepted: 07/02/2019] [Indexed: 02/05/2023]
Abstract
We developed a novel manganese (Mn2+ ) chelate for magnetic resonance imaging (MRI) assessment of myocardial viability in acute and chronic myocardial infarct (MI) models, and compared it with Gadolinium-based delay enhancement MRI (Gd3+ -DEMRI) and histology. MI was induced in 14 rabbits by permanent occlusion of the left circumflex coronary artery. Gd3+ -DEMRI and Mn2+ chelate-based delayed enhancement MRI (Mn2+ chelate-DEMRI) were performed at 7 days (acute MI, n = 8) or 8 weeks (chronic MI, n = 6) after surgery with sequential injection of 0.15 mmol/kg Gd3+ and Mn2+ chelate. The biodistribution of Mn2+ in tissues and blood was measured at 1.5 and 24 h. Blood pressure, heart rate (HR), left ventricular (LV) function, and infarct fraction (IF) were analyzed, and IF was compared with the histology. The Mn2+ chelate group maintained a stable hemodynamic status during experiment. For acute and chronic MI, all rabbits survived without significant differences in HR or LV function before and after injection of Mn2+ chelate or Gd3+ (p > 0.05). Mn2+ chelate mainly accumulated in the kidney, liver, spleen, and heart at 1.5 h, with low tissue uptake and urine residue at 24 h after injection. In the acute MI group, there was no significant difference in IF between Mn2+ chelate-DEMRI and histology (22.92 ± 2.21% vs. 21.79 ± 2.25%, respectively, p = 0.87), while Gd3+ -DEMRI overestimated IF, as compared with histology (24.54 ± 1.73%, p = 0.04). In the chronic MI group, there was no significant difference in IF between the Mn2+ chelate-DEMRI, Gd3+ -DEMRI, and histology (29.50 ± 11.39%, 29.95 ± 9.40%, and 29.00 ± 10.44%, respectively, p > 0.05), and all three were well correlated (r = 0.92-0.96, p < 0.01). We conclude that the use of Mn2+ chelate-DEMRI is reliable for MI visualization and identifies acute MI more accurately than Gd3+ -DEMRI.
Collapse
|
230
|
Characterization and Relaxation Properties of a Series of Monodispersed Magnetic Nanoparticles. SENSORS 2019; 19:s19153396. [PMID: 31382433 PMCID: PMC6696352 DOI: 10.3390/s19153396] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 07/24/2019] [Accepted: 07/31/2019] [Indexed: 01/09/2023]
Abstract
Magnetic iron oxide nanoparticles are relatively advanced nanomaterials, and are widely used in biology, physics and medicine, especially as contrast agents for magnetic resonance imaging. Characterization of the properties of magnetic nanoparticles plays an important role in the application of magnetic particles. As a contrast agent, the relaxation rate directly affects image enhancement. We characterized a series of monodispersed magnetic nanoparticles using different methods and measured their relaxation rates using a 0.47 T low-field Nuclear Magnetic Resonance instrument. Generally speaking, the properties of magnetic nanoparticles are closely related to their particle sizes; however, neither longitudinal relaxation rate r1 nor transverse relaxation rate r2 changes monotonously with the particle size d. Therefore, size can affect the magnetism of magnetic nanoparticles, but it is not the only factor. Then, we defined the relaxation rates ri′ (i = 1 or 2) using the induced magnetization of magnetic nanoparticles, and found that the correlation relationship between r1′ relaxation rate and r1 relaxation rate is slightly worse, with a correlation coefficient of R2 = 0.8939, while the correlation relationship between r2′ relaxation rate and r2 relaxation rate is very obvious, with a correlation coefficient of R2 = 0.9983. The main reason is that r2 relaxation rate is related to the magnetic field inhomogeneity, produced by magnetic nanoparticles; however r1 relaxation rate is mainly a result of the direct interaction of hydrogen nucleus in water molecules and the metal ions in magnetic nanoparticles to shorten the T1 relaxation time, so it is not directly related to magnetic field inhomogeneity.
Collapse
|
231
|
Sun IC, Ahn CH, Kim K, Emelianov S. Photoacoustic imaging of cancer cells with glycol-chitosan-coated gold nanoparticles as contrast agents. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-5. [PMID: 31385483 PMCID: PMC6680094 DOI: 10.1117/1.jbo.24.12.121903] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Accepted: 07/11/2019] [Indexed: 05/07/2023]
Abstract
Utility of glycol-chitosan-coated gold nanoparticles (GC-AuNPs) as a photoacoustic contrast agent for cancer cell imaging was demonstrated. Through the synergistic effect of glycol chitosan and gold nanoparticles, GC-AuNPs showed cellular uptake in breast cancer cells and resulted in strong photoacoustic signals in tissue-mimicking cell phantoms. The performance of GC-AuNPs as contrast agents was established with photoacoustic imaging and confirmed with dark-field microscopy. The cell phantoms displayed strong photoacoustic signals if cells were incubated more than 3 h with GC-AuNPs, compared with PEG-AuNPs that showed no photoacoustic signal increase. The enhanced photoacoustic signals originated from the plasmon coupling effect of GC-AuNPs after the cellular uptake in cancer cells. Importantly, photoacoustic imaging of cancer cells was achieved with GC-AuNPs—contrast agents that did not require antibodies or complex surface modification. The endocytosis of GC-AuNPs was also confirmed with dark-field microscopy. The results show that GC-AuNPs have potential as a photoacoustic contrast agent for cellular imaging including tumor tissue imaging.
Collapse
|
232
|
Zhang J, Yuan Y, Gao M, Han Z, Chu C, Li Y, van Zijl PCM, Ying M, Bulte JWM, Liu G. Carbon Dots as a New Class of Diamagnetic Chemical Exchange Saturation Transfer (diaCEST) MRI Contrast Agents. Angew Chem Int Ed Engl 2019; 58:9871-9875. [PMID: 31162873 PMCID: PMC6897491 DOI: 10.1002/anie.201904722] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Indexed: 12/22/2022]
Abstract
While carbon dots (C-dots) have been extensively investigated pertaining to their fluorescent, phosphorescent, electrochemiluminescent, optoelectronic, and catalytic features, their inherent chemical exchange saturation transfer magnetic resonance imaging (CEST MRI) properties are unknown. By virtue of their hydrophilicity and abundant exchangeable protons of hydroxyl, amine, and amide anchored on the surface, we report here that C-dots can be adapted as effective diamagnetic CEST (diaCEST) MRI contrast agents. As a proof-of-concept demonstration, human glioma cells were labeled with liposomes with or without encapsulated C-dots and implanted in mouse brain. In vivo CEST MRI was able to clearly differentiate labeled cells from non-labeled cells. The present findings may encourage new applications of C-dots for in vivo imaging in deep tissues, which is currently not possible using conventional fluorescent (near-infrared) C-dots.
Collapse
|
233
|
Kang HY, Kim JE, Kim YJ, Park SW, Kim Y. An Unusual Delayed Onset of Systemic Toxicity After Fluoroscopy-Guided Cervical Epidural Steroid Injection With Levobupivacaine: A Case Report. Pain Pract 2019; 19:762-766. [PMID: 31165535 DOI: 10.1111/papr.12802] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 05/15/2019] [Accepted: 05/31/2019] [Indexed: 11/30/2022]
Abstract
BACKGROUND Cervical epidural steroid injection (CESI) with local anesthetics is commonly used to treat neck pain and radicular pain of the upper extremity. Local anesthetic systemic toxicity (LAST) occurs shortly after injection as a complication; however, delayed onset is a very rare event, especially in central nervous system (CNS) block. CASE REPORT We present a case in which delayed onset of LAST occurred in a patient who received CESI for cervical and arm radiating pain due to a cervical disc protrusion. We performed the interlaminar approach for CESI using fluoroscopic guidance. After confirming the location of the epidural space using the loss of resistance technique and spreading of contrast agent (Telebrix® 30), a mixture of 0.25% levobupivacaine 12.5 mg (5 mL in volume), hyaluronidase 1,500 IU (1 mL), dexamethasone 5 mg (1 mL), and normal saline 3 mL was administrated. After 50 minutes of injection, the patient showed CNS toxicity (unconsciousness, seizure) with normal blood pressure and tachycardia; therefore, she was immediately sedated with intravenous midazolam (3 mg), and 15 L/min of oxygen was administered. The patient fully recovered after 30 minutes of sedation without any sequelae. CONCLUSION Delayed onset of LAST is a rare complication of a common procedure in CESI, so it is important to be aware of this complication and the presentation of toxicity.
Collapse
|
234
|
Chen S, Xu XL, Zhou B, Tian J, Luo BM, Zhang LM. Acidic pH-Activated Gas-Generating Nanoparticles with Pullulan Decorating for Hepatoma-Targeted Ultrasound Imaging. ACS APPLIED MATERIALS & INTERFACES 2019; 11:22194-22205. [PMID: 31199110 DOI: 10.1021/acsami.9b06745] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Contrast-enhanced ultrasound (US) is a widely used imaging modality for hepatocellular carcinoma diagnosis. Mostly, US imaging is confined to the intravascular process because of the limitation of the microbubble contrast agent currently utilized. Targeted contrast agents that incline to accumulate in tumor tissue or tumor cells and enhance the US signal may advance the sensitivity of ultrasonography and exploit the dimension of US imaging of tumor at the molecular level. In this study, we developed CaCO3/pul-PCB (CPP) hybrid nanoparticles with hepatoma-targeting pullulan decorating on the surface through a mineralization route using the pullulan- graft-poly(carboxybetaine methacrylate) (pul-PCB) copolymer as a modifier. This particle was stable in blood physiological pH and generated echogenic CO2 bubbles under tumoral acidic conditions, which enabled the US signal enhancement. Upon intravenous injection, CPP hybrid nanoparticles accumulated efficiently in tumor tissue and exhibited sixfold contrast enhancement in 35 min at the tumor site in the hepatoma-bearing mice model. By contrast, there was barely any signal change in normal liver tissue. Therefore, the presented CPP hybrid nanoparticle is a promising contrast agent for effective US imaging of hepatoma.
Collapse
|
235
|
Meloni MM, Barton S, Kaski JC, Song W, He T. An improved synthesis of a cyclopropene-based molecule for the fabrication of bioengineered tissues via copper-free click chemistry. J Appl Biomater Funct Mater 2019; 17:2280800019844746. [PMID: 31223071 DOI: 10.1177/2280800019844746] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Since its introduction in the field of biological imaging, the use of copper-free click chemistry has been extended to produce improved materials for vascular surgery, ophthalmology, environmental, and automotive applications. This wide applicability suggests that larger quantities of the chemical reagents for copper-free click chemistry will be required in the future. However, the large-scale synthesis of such chemicals has been barely investigated. A possible reason is the shortage of reliable synthetic protocols to obtain large quantities of these building blocks. We therefore present in this paper an improved synthetic protocol to obtain a cyclopropene-based carbonate, a key building block for the well-known copper-free click chemistry. METHOD Our protocol builds upon an already available method to obtain a cyclopropene-based carbonate. When scaled up, several parameters of this method were changed in order to obtain an improved yield. First, the use of lower temperatures and slower addition rates of the chemicals avoided the formation of detrimental hotspots in the reaction system. Second, the use of less hygroscopic solvents minimized the decomposition of the cyclopropene carbonate. Finally, chromatographic purifications were minimized and improved by using deactivated silica. RESULTS We obtained the compound (2-methylcycloprop-2-en-1-yl)methyl (4-nitrophenyl) carbonate, a key building block for copper-free click chemistry, in an unprecedented 60% overall yield on a six-gram scale. CONCLUSIONS Our improved synthetic protocol demonstrates the potential of large-scale production of improved materials using click chemistry, with potential future applications in the fields of molecular imaging, vascular surgery, ophthalmology, and theranostics.
Collapse
|
236
|
Jiang Z, Lin C, Liu H, Feng J, Zheng Z, Cai S. Specific biological responses following dextran-coated ultra-small superparamagnetic particles of iron oxides administration. Nanomedicine (Lond) 2019; 14:1371-1386. [PMID: 31215328 DOI: 10.2217/nnm-2018-0433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Aim: The potential bio-related risks of dextran-coated ultra-small superparamagnetic particles of iron oxides (D-USPIO) were assessed. Materials & methods: Metabolic responses of D-USPIO in BALB/C mice were obtained using 1H-NMR-based metabolomic strategy combined with the traditional biochemical assay. Results: The metabolomic analyses of biological fluids (plasma and urine) and organs (liver, kidney and spleen) indicated that the disturbance, impairment and recovery of the physiological functions were related to the metabolic response to D-USPIO. The correlations between the biofluids and tissue metabolomes described the specific metabolic information of D-USPIO on their in vivo transportation, absorption, biodistribution and excretion. Conclusion: Metabolomic analysis provides preliminary validation for the use of D-USPIO in clinical medicine, and the results help to understand the potential adverse effects of the similar bio-nanomaterials further serve to their synthesis optimization and biocompatibility improvement.
Collapse
|
237
|
Liu L, Liu L, Li Y, Huang X, Gu D, Wei B, Su D, Jin G. Ultrasmall superparamagnetic nanoparticles targeting E-selectin: synthesis and effects in mice in vitro and in vivo. Int J Nanomedicine 2019; 14:4517-4528. [PMID: 31354271 PMCID: PMC6590629 DOI: 10.2147/ijn.s199571] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Accepted: 05/01/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose: We developed a contrast agent for targeting E-selectin expression. We detected the agent using magnetic resonance imaging (MRI) in vivo in nude mice that had undergone nasopharyngeal carcinoma (NPC) metastasis. Methods: Sialyl Lewis X (sLeX) was conjugated with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. Hydrodynamic size, polydispersity index, and ζ-potential of USPIO–polyethylene glycol (PEG) nanoparticles and USPIO-PEG-sLeX nanoparticles were measured. Component changes in nanoparticles of USPIO, USPIO-PEG, and USPIO-PEG-sLeX were analyzed by thermogravimetric analysis and Fourier-transform infrared spectroscopy. A model of NPC metastasis to inguinal lymph nodes in nude mice was used to investigate characteristics of the USPIO-PEG-sLeX nanoparticles in vivo. We investigated the ability of the T2* value, change in T2* value (ΔT2* value), and enhancement rate (ER) to assess accumulation of USPIO-PEG-sLeX nanoparticles quantitatively in mice of a metastasis group and control group. Four MRI scans were undertaken for each mouse. The first scan (t0) was done before administration of USPIO-PEG-sLeX nanoparticles (0.1 mL) via the tail vein. The other scans were carried out at 0 (t1), 1 (t2), and 2 hours (t3) postinjection. The mean optical density was used to reflect E-selectin expression. Results: sLeX was labeled onto USPIO successfully. In vivo, there were significant interactions between the groups and time for T2* values after administration of USPIO-PEG-sLeX nanoparticles. Six parameters (T2* at t2, ΔT2* at t1, ΔT2* at t2, ER at t1, ER at t2, and ER at t3) were correlated with the mean optical density. Conclusion: USPIO-PEG-sLeX nanoparticles can be used to assess E-selectin expression quantitatively. Use of such molecular probes could enable detection of early metastasis of NPC, more accurate staging, and treatment monitoring.
Collapse
|
238
|
Impaired Glymphatic Transport in Spontaneously Hypertensive Rats. J Neurosci 2019; 39:6365-6377. [PMID: 31209176 DOI: 10.1523/jneurosci.1974-18.2019] [Citation(s) in RCA: 127] [Impact Index Per Article: 25.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 03/31/2019] [Accepted: 05/30/2019] [Indexed: 12/21/2022] Open
Abstract
The glymphatic system is a brainwide CSF transport system that uses the perivascular space for fast inflow of CSF. Arterial pulsations are a major driver of glymphatic CSF inflow, and hypertension that causes vascular pathologies, such as arterial stiffening and perivascular alterations, may impede the inflow. We used dynamic contrast-enhanced MRI to assess the effect of hypertension on glymphatic transport kinetics in male young and adult spontaneously hypertensive (SHR) rats compared with age-matched normotensive Wistar-Kyoto rats (WKY). We anesthetized the rats with dexmedetomidine/isoflurane and infused paramagnetic contrast (Gd-DOTA) into the cisterna magna during dynamic contrast-enhanced MRI to quantify glymphatic transport kinetics. Structural MRI analysis showed that cerebroventricular volumes are larger and brain volumes significantly smaller in SHR compared with WKY rats, regardless of age. We observed ventricular reflux of Gd-DOTA in SHR rats only, indicating abnormal CSF flow dynamics secondary to innate hydrocephalus. One-tissue compartment analysis revealed impeded glymphatic transport of Gd-DOTA in SHR compared with WKY rats in both age groups, implying that glymphatic transport, including solute clearance from brain parenchyma, is impaired during evolving hypertension in young SHR, an effect that worsens in states of chronic hypertension. The study demonstrates the suppression of glymphatic clearance in SHR rats and thus offers new insight into the coexistence of hypertension and concomitant vascular pathologies in Alzheimer's disease. The study further highlights the importance of considering the distribution of tracers in the CSF compartment in the analysis of the glymphatic system.SIGNIFICANCE STATEMENT The glymphatic system contributes to the removal of amyloid β from the brain and is disrupted in Alzheimer's disease and aging. Using a rat model of hypertension, we measured gross CSF flow and tracked glymphatic influx and efflux rates with dynamic contrast-enhanced MRI, showing that glymphatic transport is compromised in both early and advanced stages of hypertension. The study provides a new perspective on the importance for brain metabolite and fluid homeostasis of maintaining healthy blood vessels, an increasingly pertinent issue in an aging population that in part may explain the link between vascular pathology and Alzheimer's disease.
Collapse
|
239
|
Shen Y, Goerner FL, Heverhagen JT, Snyder C, Hu D, Li X, Runge VM. In vitro T2 relaxivities of the Gd-based contrast agents (GBCAs) in human blood at 1.5 and 3 T. Acta Radiol 2019; 60:694-701. [PMID: 30205704 DOI: 10.1177/0284185118799538] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND The availability of data in the medical literature for the T2 relaxivities of the Gd-based contrast agents (GBCAs) is limited. A comprehensive comparison between the agents available commercially (other than in Europe) is lacking, with no data available that most closely reflect the clinic, which is in human whole blood at body temperature. PURPOSE To complement the existing literature by determining T2 relaxivity data for eight GBCAs in vitro. MATERIAL AND METHODS The relaxivities of eight GBCAs diluted in human whole blood at 1.5 and 3 T were determined at 37 ± 0.5 °C. Gd was in the range of 0-4 mM. Multi-echo sequences with variable echo times were acquired using a phantom containing a dilution series with each agent, and SigmaPlot 12.0 was used to calculate the R2 relaxation rate and finally r2. Statistical comparisons between agents and field strengths were conducted. RESULTS The relationship between R2 vs. Gd was observed to be linear at 1.5 and 3 T, with a mild increase in r2 from 1.5 to 3 T for all GBCAs. T2 relaxivity data were compared with prior results. The GBCAs are closely clustered into two groups, with higher r2 noted for the two lipophilic (those with partial hepatobiliary excretion) compounds. CONCLUSION The r2 values at 1.5 and 3 T, determined for the eight GBCAs still clinically available (other than in Europe), provide a definitive baseline for future evaluations, including theoretical calculations of signal intensity and their clinical impact on T2-weighted scans.
Collapse
|
240
|
Ring HC, Israelsen NM, Bang O, Haedersdal M, Mogensen M. Potential of contrast agents to enhance in vivo confocal microscopy and optical coherence tomography in dermatology: A review. JOURNAL OF BIOPHOTONICS 2019; 12:e201800462. [PMID: 30851078 DOI: 10.1002/jbio.201800462] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Revised: 03/02/2019] [Accepted: 03/07/2019] [Indexed: 06/09/2023]
Abstract
Distinction between normal skin and pathology can be a diagnostic challenge. This systematic review summarizes how various contrast agents, either topically delivered or injected into the skin, affect distinction between skin disease and normal skin when imaged by optical coherence tomography (OCT) and confocal microscopy (CM). A systematic review of in vivo OCT and CM studies using exogenous contrast agents on healthy human skin or skin disease was performed. In total, nine CM studies and one OCT study were eligible. Four contrast agents aluminum chloride (AlCl) n = 2, indocyanine green (ICG) n = 3, sodium fluorescein n = 3 and acetic acid n = 1 applied to CM in variety of skin diseases. ICG, acetic acid and AlCl showed promise to increase contrast of tumor nests in keratinocyte carcinomas. Fluorescein and ICG enhanced contrast of keratinocytes and adnexal structures. In OCT of healthy skin gold nanoshells, increased contrast of natural skin openings. Contrast agents may improve delineation and diagnosis of skin cancers; ICG, acetic acid and AlCl have potential in CM and gold nanoshells facilitate visualization of adnexal skin structures in OCT. However, as utility of bedside optical imaging increases, further studies with robust methodological quality are necessary to implement contrast agents into routine dermatological practice.
Collapse
|
241
|
Goebel J, Steinmann J, Heintschel von Heinegg E, Hestermann T, Nassenstein K. Bacterial contamination of automated MRI contrast injectors in clinical routine. GMS HYGIENE AND INFECTION CONTROL 2019; 14:Doc05. [PMID: 31198659 PMCID: PMC6545436 DOI: 10.3205/dgkh000321] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Aim: To quantify the frequency of bacterial contamination of the injected contrast agent/saline solution by an automated contrast injection system, and to evaluate whether usage of a novel tube system can reduce it. Methods: For bacterial contamination quantification two identical automated piston pump MRI contrast injectors were used in combination with a standard tube system. 3-5 ml of the contrast agent/saline solution was collected from the system prior to its connection to the patients' venous cannula in 104 consecutive patients. To test, whether a novel tube system reduces contamination, a tube system with shielded screw connections was used with the same contrast injectors and contrast agent/saline samples were collected in further 101 patients. Specimens were microbiologically analyzed. Frequencies of contamination were compared using Fisher exact test. Results: With the standard tube system, bacterial contamination was observed in 5.8% (6 out of 104 specimens). With the novel tube system, contamination was observed in 2.0% (2 out of 101 specimens, p=0.280). Staphylococcus epidermidis was the most common germ (5 cases) followed by Micrococcus luteus (2 cases) and Oligella ureolytica (1 case). Conclusion: Bacterial contaminations of MRI contrast injectors occurred in a non-negligible frequency especially with S. epidermidis. A trend towards reduced bacterial contamination was seen when a novel tube system with shielded screw connections was used.
Collapse
|
242
|
Vu-Quang H, Vinding MS, Nielsen T, Ullisch MG, Nielsen NC, Nguyen DT, Kjems J. Pluronic F127-Folate Coated Super Paramagenic Iron Oxide Nanoparticles as Contrast Agent for Cancer Diagnosis in Magnetic Resonance Imaging. Polymers (Basel) 2019; 11:polym11040743. [PMID: 31027171 PMCID: PMC6523503 DOI: 10.3390/polym11040743] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 04/09/2019] [Accepted: 04/13/2019] [Indexed: 11/17/2022] Open
Abstract
Contrast agents have been widely used in medicine to enhance contrast in magnetic resonance imaging (MRI). Among them, super paramagnetic iron oxide nanoparticles (SPION) have been reported to have low risk in clinical use. In our study, F127-Folate coated SPION was fabricated in order to efficiently target tumors and provide imaging contrast in MRI. SPION alone have an average core size of 15 nm. After stabilizing with Pluronic F127, the nanoparticles reached a hydrodynamic size of 180 nm and dispersed well in various kinds of media. The F127-Folate coated SPION were shown to specifically target folate receptor expressing cancer cells by flow cytometry analysis, confocal laser scanning microscope, as well as in vitro MRI. Furthermore, in vivo MRI images have shown the enhanced negative contrast from the F127-Folate coated SPION in tumor-bearing mice. In conclusion, our F127-Folate coated SPION have shown great potential as a contrast agent in MRI, as well as in the combination with drug delivery for cancer therapy.
Collapse
|
243
|
Zhao L, Bao J, Guo Y, Li J, Yang X, Lv T, Hao F, Wang Z, Yang Z, Liu A. Ultra-low dose one-step CT angiography for coronary, carotid and cerebral arteries using 128-slice dual-source CT: A feasibility study. Exp Ther Med 2019; 17:4167-4175. [PMID: 30988794 PMCID: PMC6447913 DOI: 10.3892/etm.2019.7420] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 03/07/2019] [Indexed: 12/19/2022] Open
Abstract
Atherosclerotic diseases are systemic and patient outcomes depend on comprehensive imaging evaluation. Computed tomography angiography (CTA) is a powerful tool used to assess atherosclerosis. However, the scanning protocol is designed for cardiovascular and cerebrovascular imaging, which require considerations into the radiation dose, contrast agent and image quality. The purpose of the present study was to evaluate ultra-low dose one-step CTA for coronary, carotid and cerebral arteries with a low concentration contrast agent. A total of 78 patients were enrolled and randomly divided into two groups: Group A (n=38) and B (n=40). High-pitch CTA for coronary, carotid and cerebral arteries with a tube voltage of 70 or 80 kVp and 40 ml contrast agent (270 mgI/ml) was performed by a 128-slice dual-source CT scanner for group A. Standard high-pitch CTA with a tube voltage of 100 kVp and 60 ml contrast agent (370 mgI/ml) was conducted for group B. The image quality, radiation dose and amount of contrast agent in group A were evaluated and compared with group B. The dose length product for groups A and B was 62.95±21.54 vs. 160.15±15.13 mGy cm, respectively (t=−23.157, P<0.001). The mean total iodine content was 10.8±0 mg for group A and 22.2±0 mg for group B. In total, 99.4% of the arterial segments could be assessed for the two groups (χ2=0.267, P=0.606). The results revealed that ultra-low dose one-step high-pitch CTA can provide assessable image quality, and minimize the radiation dose and contrast agent.
Collapse
|
244
|
Augmentation of Electrocardiographic QRS R-Amplitude Precedes Radiocontrast-Induced Hypotension during Mobile Computed Tomography Scanning. J Clin Med 2019; 8:jcm8040505. [PMID: 31013769 PMCID: PMC6518100 DOI: 10.3390/jcm8040505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 04/05/2019] [Accepted: 04/10/2019] [Indexed: 11/16/2022] Open
Abstract
Although intravenous administration of contrast media may trigger a variety of adverse reactions, sedated patients undergoing computed tomography (CT) scanning usually are not able to report their symptoms, which may delay detection of adverse reactions. Furthermore, changes in vital signs cannot be typically measured during mobile CT scanning, which worsens the situation. We aimed to characterize contrast-related hemodynamic changes that occur during mobile CT scanning and predict sudden hypotension based on subtle but robust changes in the electrocardiogram (ECG). We analyzed the digitized hemodynamic data of 20 consecutive patients who underwent clipping of a cerebral artery aneurysm and contrast-enhanced CT scanning following the surgical procedure. Hemodynamic variables, including ECG findings, invasive blood pressure (BP), pulse oximetry results, capnography findings, cardiac output, and systemic vascular resistance, were monitored simultaneously. We measured morphological changes in ECG-derived parameters, including the R-R interval, ST height, and QRS R-amplitude, on a beat-to-beat basis, and evaluated the correlation between those parameters and hemodynamic changes. After the radiocontrast injection, systolic BP decreased by a median 53 mmHg from baseline and spontaneously recovered after 63 ± 19 s. An increase in QRS R-amplitude (median 0.43 mV) occurred 25 ± 10 s before hypotension developed. The receiver operating characteristic curve showed that a 16% increase in QRS R-amplitude can predict a decrease in systolic BP of >25% (area under the curve 0.852). Increased cardiac output (median delta 2.7 L/min from baseline) and decreased systemic vascular resistance (median delta 857 dyn·s/cm5 from baseline) were also observed during hypotension. During mobile CT scanning, profound but transient hypotension can be observed, associated with decreased vascular resistance. Augmentation of QRS R-amplitude from an ECG represents a sensitive surrogate for onset of a hypotensive episode after contrast injection, thereby serving as a simple and continuous noninvasive hemodynamic monitoring tool.
Collapse
|
245
|
Biomedical Imaging: Principles, Technologies, Clinical Aspects, Contrast Agents, Limitations and Future Trends in Nanomedicines. Pharm Res 2019; 36:78. [PMID: 30945009 DOI: 10.1007/s11095-019-2608-5] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Accepted: 03/11/2019] [Indexed: 12/11/2022]
Abstract
This review article presents the state-of-the-art in the major imaging modalities supplying relevant information on patient health by real-time monitoring to establish an accurate diagnosis and potential treatment plan. We draw a comprehensive comparison between all imagers and ultimately end with our focus on two main types of scanners: X-ray CT and MRI scanners. Numerous types of imaging probes for both imaging techniques are described, as well as reviewing their strengths and limitations, thereby showing the current need for the development of new diagnostic contrast agents (CAs). The role of nanoparticles in the design of CAs is then extensively detailed, reviewed and discussed. We show how nanoparticulate agents should be promising alternatives to molecular ones and how they are already paving new routes in the field of nanomedicine.
Collapse
|
246
|
Kang B, Lim J, Son HY, Choi Y, Kang T, Jung J, Huh YM, Haam S, Lim EK. PEGylated Magnetic Nano-Assemblies as Contrast Agents for Effective T2-Weighted MR Imaging. NANOMATERIALS 2019; 9:nano9030410. [PMID: 30862030 PMCID: PMC6473972 DOI: 10.3390/nano9030410] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 03/04/2019] [Accepted: 03/06/2019] [Indexed: 12/12/2022]
Abstract
We designed a high-sensitivity magnetic resonance imaging contrast agent that could be used to diagnose diseases. First, magnetic nanocrystals were synthesized by a thermal decomposition method on an organic solvent to obtain a high magnetism and methoxy poly(ethylene glycol)-poly(lactic acid) as an amphiphilic polymer using the ring-opening polymerization method to stably disperse the magnetic nanocrystals in an aqueous phase. Subsequently, the magnetic nanoclusters simultaneously self-assembled with methoxy poly(ethylene glycol)-poly(lactic acid) using the nano-emulsion method to form magnetic nanoclusters. Because their shape was similar to a raspberry, they were named PEGylated magnetic nano-assemblies. The PEGylated magnetic nano-assemblies were dispersed stably in the aqueous phase with a uniform size of approximately 65–70 nm for an extended period (0 days: 68.8 ± 5.1 nm, 33 days: 69.2 ± 2.0 nm, and 44 days: 63.2 ± 5.6). They exhibited both enough of a magnetic resonance (MR) contrast effect and biocompatibility. In an in vivo study, the PEGylated magnetic nano-assemblies provided a high contrast effect for magnetic resonance images for a long time after one treatment, thereby improving the diagnostic visibility of the disease site.
Collapse
|
247
|
Mezian K, Chang KV. Contrast-enhanced Ultrasonography for the Diagnosis of Frozen Shoulder. J Med Ultrasound 2019; 27:146-147. [PMID: 31867178 PMCID: PMC6905277 DOI: 10.4103/jmu.jmu_103_18] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 12/12/2018] [Indexed: 11/05/2022] Open
Abstract
Introduction: Adhesive capsulitis (AC), also known as frozen shoulder, is challenging for diagnosis, particularly in early stages. A promising tool is contrast-enhanced ultrasonography (CEUS), which has been successfully applied on musculoskeletal ultrasonography. Methods and Results: Two antecedent studies reported the application of CEUS on AC patients although different methods were used. The first research team administered the contrast media intravenously to facilitate detection of microcirculation through observing different distributions of time–intensity curves between the affected and unaffected shoulders. The second study has introduced a pioneering approach, injecting the contrast media mixed with saline directly into the glenohumeral joint. The authors designated this novel method as “US arthrography”. According to our best knowledge, this is the first study reporting the application of intraarticular CEUS in humans. Conclusion: Both presented studies reported CEUS to be capable of differentiating shoulders with AC from normal controls.
Collapse
|
248
|
Murphy A, Cheng J, Pratap J, Redman R, Coucher J. Dual-Energy Computed Tomography Pulmonary Angiography: Comparison of Vessel Enhancement between Linear Blended and Virtual Monoenergetic Reconstruction Techniques. J Med Imaging Radiat Sci 2019; 50:62-67. [PMID: 30777250 DOI: 10.1016/j.jmir.2018.10.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 10/18/2018] [Accepted: 10/18/2018] [Indexed: 12/29/2022]
Abstract
INTRODUCTION Optimal opacification of the pulmonary vasculature is a fundamental factor of a diagnostic quality computed tomography pulmonary angiogram (CTPA). This retrospective study examined the feasibility of utilising a noise-optimised monoenergetic reconstruction of the dual-energy computed tomography pulmonary angiogram (DE-CTPA) as an additional protocol to increase vessel opacification. METHOD The study involved a retrospective analysis of 129 patients, 69 males (average age 58 years), 60 females (average age 56 years) who underwent a DE-CTPA at a tertiary referral hospital. Linear blended 120 kilovoltage (kV) images (LB120) dual-energy (DE) data sets (50% 100 kV and 50% 140 kV) were compared to noise-optimised virtual monoenergetic image reconstruction (VMI+) at 40 kiloelectron volts (VMI+40). The attenuation of the pulmonary trunk measured in Hounsfield units (HU) between the equivalent axial slices of the LB120 data set and the VMI+40 data set underwent statistical analysis via a Wilcoxon paired-sample test. RESULTS VMI+40 (1161.500 HU) yielded a statistically significant increase in median attenuation within the pulmonary trunk compared to the LB120 (304.400 HU), with a median difference between monoenergetic reconstruction and standard dual energy of data sets of 827.5 HU (P < .001). CONCLUSIONS VMI+40 of the DE-CTPA scan demonstrates a statistically significant increase in vessel attenuation in all cases and may have utility in reducing the rates of indeterminate or repeated studies.
Collapse
|
249
|
Li W, Song W, Chen B, Matcher SJ. Superparamagnetic graphene quantum dot as a dual-modality contrast agent for confocal fluorescence microscopy and magnetomotive optical coherence tomography. JOURNAL OF BIOPHOTONICS 2019; 12:e201800219. [PMID: 30191684 DOI: 10.1002/jbio.201800219] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Accepted: 09/04/2018] [Indexed: 05/03/2023]
Abstract
A magnetic graphene quantum dot (MGQD) nanoparticle, synthesized by hydrothermally reducing and cutting graphene oxide-iron oxide sheet, was demonstrated to possess the capabilities of simultaneous confocal fluorescence and magnetomotive optical coherence tomography (MMOCT) imaging. This MGQD shows low toxicity, significant tunable blue fluorescence and superparamagnetism, which can thus be used as a dual-modality contrast agent for confocal fluorescence microscopy (CFM) and MMOCT. The feasibility of applying MGQD as a tracer of cells is shown by imaging and visualizing MGQD labeled cells using CFM and our in-house MMOCT. Since MMOCT and CFM can offer anatomical structure and intracellular details, respectively, the MGQD for cell tracking could provide a more comprehensive diagnosis.
Collapse
|
250
|
Anthony GJ, Bader KB, Wang J, Zamora M, Ostdiek A, Antic T, Krueger S, Weiss S, Trogler WC, Blair SL, Kummel AC, Sammet S. MRI-guided transurethral insonation of silica-shell phase-shift emulsions in the prostate with an advanced navigation platform. Med Phys 2019; 46:774-788. [PMID: 30414276 PMCID: PMC6367027 DOI: 10.1002/mp.13279] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 10/24/2018] [Accepted: 10/26/2018] [Indexed: 02/05/2023] Open
Abstract
PURPOSE In this study, the efficacy of transurethral prostate ablation in the presence of silica-shell ultrasound-triggered phase-shift emulsions (sUPEs) doped with MR contrast was evaluated. The influence of sUPEs on MR imaging assessment of the ablation zone was also investigated. METHODS sUPEs were doped with a magnetic resonance (MR) contrast agent, Gd2 O3 , to assess ultrasound transition. Injections of saline (sham), saline and sUPEs alone, and saline and sUPEs with Optison microbubbles were performed under guidance of a prototype interventional MRI navigation platform in a healthy canine prostate. Treatment arms were evaluated for differences in lesion size, T1 contrast, and temperature. In addition, non-perfused areas (NPAs) on dynamic contrast-enhanced (DCE) MRI, 55°C isotherms, and areas of 240 cumulative equivalent minutes at 43°C (CEM43 ) dose or greater computed from MR thermometry were measured and correlated with ablated areas indicated by histology. RESULTS For treatment arms including sUPEs, the computed correlation coefficients between the histological ablation zone and the NPA, 55°C isotherm, and 240 CEM43 area ranged from 0.96-0.99, 0.98-0.99, and 0.91-0.99, respectively. In the absence of sUPEs, the computed correlation coefficients between the histological ablation zone and the NPA, 55°C isotherm, and 240 CEM43 area were 0.69, 0.54, and 0.50, respectively. Across all treatment arms, the areas of thermal tissue damage and NPAs were not significantly different (P = 0.47). Areas denoted by 55°C isotherms and 240 CEM43 dose boundaries were significantly larger than the areas of thermal damage, again for all treatment arms (P = 0.009 and 0.003, respectively). No significant differences in lesion size, T1 contrast, or temperature were observed between any of the treatment arms (P > 0.0167). Lesions exhibiting thermal fixation on histological analysis were present in six of nine insonations involving sUPE injections and one of five insonations involving saline sham injections. Significantly larger areas (P = 0.002), higher temperatures (P = 0.004), and more frequent ring patterns of restricted diffusion on ex vivo diffusion-weighted imaging (P = 0.005) were apparent in lesions with thermal fixation. CONCLUSIONS T1 contrast suggesting sUPE transition was not evident in sUPE treatment arms. The use of MR imaging metrics to predict prostate ablation was not diminished by the presence of sUPEs. Lesions generated in the presence of sUPEs exhibited more frequent thermal fixation, though there were no significant changes in the ablation areas when comparing arms with and without sUPEs. Thermal fixation corresponded to some qualitative imaging features.
Collapse
|