26
|
Hill CA, Kusaka A, Ashton P, Barton P, Adkins T, Arnold K, Bixler B, Ganjam S, Lee AT, Matsuda F, Matsumura T, Sakurai Y, Tat R, Zhou Y. A cryogenic continuously rotating half-wave plate mechanism for the POLARBEAR-2b cosmic microwave background receiver. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:124503. [PMID: 33380005 DOI: 10.1063/5.0029006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 11/15/2020] [Indexed: 06/12/2023]
Abstract
We present the design and laboratory evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the POLARBEAR-2b (PB-2b) cosmic microwave background receiver, the second installment of the Simons Array. PB-2b will observe at 5200 m elevation in the Atacama Desert of Chile in two frequency bands centered at 90 GHz and 150 GHz. In order to suppress atmospheric 1/f noise and mitigate systematic effects that arise when differencing orthogonal detectors, PB-2b modulates linear sky polarization using a CHWP rotating at 2 Hz. The CHWP has a 440 mm clear aperture diameter and is cooled to ≈50 K in the PB-2b receiver cryostat. It consists of a low-friction superconducting magnetic bearing and a low-torque synchronous electromagnetic motor, which together dissipate <2 W. During cooldown, a grip-and-release mechanism centers the rotor to <0.5 mm, and during continuous rotation, an incremental optical encoder measures the rotor angle with a noise level of 0.1 μrad/Hz. We discuss the experimental requirements for the PB-2b CHWP, the designs of its various subsystems, and the results of its evaluation in the laboratory. The presented CHWP has been deployed to Chile and is expected to see first light on PB-2b in 2020 or 2021.
Collapse
|
27
|
Calderon-Rojas R, Nguyen A, Nishimura RA, Geske JB, Ommen SR, King KS, Lee AT, Dearani JA, Schaff HV. Is there referral bias in outcomes of septal myectomy for hypertrophic cardiomyopathy? J Thorac Cardiovasc Surg 2020; 164:881-891. [DOI: 10.1016/j.jtcvs.2020.08.118] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 08/18/2020] [Accepted: 08/30/2020] [Indexed: 10/23/2022]
|
28
|
Kunneman M, Branda ME, Hargraves IG, Sivly AL, Lee AT, Gorr H, Burnett B, Suzuki T, Jackson EA, Hess E, Linzer M, Brand-McCarthy SR, Brito JP, Noseworthy PA, Montori VM. Assessment of Shared Decision-making for Stroke Prevention in Patients With Atrial Fibrillation: A Randomized Clinical Trial. JAMA Intern Med 2020; 180:1215-1224. [PMID: 32897386 PMCID: PMC7372497 DOI: 10.1001/jamainternmed.2020.2908] [Citation(s) in RCA: 62] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
IMPORTANCE Shared decision-making (SDM) about anticoagulant treatment in patients with atrial fibrillation (AF) is widely recommended but its effectiveness is unclear. OBJECTIVE To assess the extent to which the use of an SDM tool affects the quality of SDM and anticoagulant treatment decisions in at-risk patients with AF. DESIGN, SETTING, AND PARTICIPANTS This encounter-randomized trial recruited patients with nonvalvular AF who were considering starting or reviewing anticoagulant treatment and their clinicians at academic, community, and safety-net medical centers between January 30, 2017 and June 27, 2019. Encounters were randomized to either the standard care arm or care that included the use of an SDM tool (intervention arm). Data were analyzed from August 1 to November 30, 2019. INTERVENTIONS Standard care or care using the Anticoagulation Choice Shared Decision Making tool (which presents individualized risk estimates and compares anticoagulant treatment options across issues of importance to patients) during the clinical encounter. MAIN OUTCOMES AND MEASURES Quality of SDM (which included quality of communication, patient knowledge about AF and anticoagulant treatment, accuracy of patient estimates of their own stroke risk [within 30% of their estimate], decisional conflict, and satisfaction), decisions made during the encounter, duration of the encounter, and clinician involvement of patients in the SDM process. RESULTS The clinical trial enrolled 922 patients (559 men [60.6%]; mean [SD] age, 71 [11] years) and 244 clinicians. A total of 463 patients were randomized to the intervention arm and 459 patients to the standard care arm. Participants in both arms reported high communication quality, high knowledge, and low decisional conflict, demonstrated low accuracy in their risk perception, and would similarly recommend the approach used in their encounter. Clinicians were significantly more satisfied after intervention encounters (400 of 453 encounters [88.3%] vs 277 of 448 encounters [61.8%]; adjusted relative risk, 1.49; 95% CI, 1.42-1.53). A total of 747 of 873 patients (85.6%) chose to start or continue receiving an anticoagulant medication. Patient involvement in decision-making (as assessed through video recordings of the encounters using the Observing Patient Involvement in Decision Making 12-item scale) scores were significantly higher in the intervention arm (mean [SD] score, 33.0 [10.8] points vs 29.1 [13.1] points, respectively; adjusted mean difference, 4.2 points; 95% CI, 2.8-5.6 points). No significant between-arm difference was found in encounter duration (mean [SD] duration, 32 [16] minutes in the intervention arm vs 31 [17] minutes in the standard care arm; adjusted mean between-arm difference, 1.1; 95% CI, -0.3 to 2.5 minutes). CONCLUSION AND RELEVANCE The use of an SDM encounter tool improved several measures of SDM quality and clinician satisfaction, with no significant effect on treatment decisions or encounter duration. These results help to calibrate expectations about the value of implementing SDM tools in the care of patients with AF. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT02905032.
Collapse
|
29
|
Adachi S, Aguilar Faúndez MAO, Akiba Y, Ali A, Arnold K, Baccigalupi C, Barron D, Beck D, Bianchini F, Borrill J, Carron J, Cheung K, Chinone Y, Crowley K, El Bouhargani H, Elleflot T, Errard J, Fabbian G, Feng C, Fujino T, Goeckner-Wald N, Hasegawa M, Hazumi M, Hill CA, Howe L, Katayama N, Keating B, Kikuchi S, Kusaka A, Lee AT, Leon D, Linder E, Lowry LN, Matsuda F, Matsumura T, Minami Y, Namikawa T, Navaroli M, Nishino H, Peloton J, Pham ATP, Poletti D, Puglisi G, Reichardt CL, Segawa Y, Sherwin BD, Silva-Feaver M, Siritanasak P, Stompor R, Tajima O, Takatori S, Tanabe D, Teply GP, Vergès C. Internal Delensing of Cosmic Microwave Background Polarization B-Modes with the POLARBEAR Experiment. PHYSICAL REVIEW LETTERS 2020; 124:131301. [PMID: 32302154 DOI: 10.1103/physrevlett.124.131301] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 12/20/2019] [Accepted: 02/26/2020] [Indexed: 06/11/2023]
Abstract
Using only cosmic microwave background polarization data from the polarbear experiment, we measure B-mode polarization delensing on subdegree scales at more than 5σ significance. We achieve a 14% B-mode power variance reduction, the highest to date for internal delensing, and improve this result to 22% by applying for the first time an iterative maximum a posteriori delensing method. Our analysis demonstrates the capability of internal delensing as a means of improving constraints on inflationary models, paving the way for the optimal analysis of next-generation primordial B-mode experiments.
Collapse
|
30
|
Nadolski A, Vieira JD, Sobrin JA, Kofman AM, Ade PAR, Ahmed Z, Anderson AJ, Avva JS, Basu Thakur R, Bender AN, Benson BA, Bryant L, Carlstrom JE, Carter FW, Cecil TW, Chang CL, Cheshire JR, Chesmore GE, Cliche JF, Cukierman A, de Haan T, Dierickx M, Ding J, Dutcher D, Everett W, Farwick J, Ferguson KR, Florez L, Foster A, Fu J, Gallicchio J, Gambrel AE, Gardner RW, Groh JC, Guns S, Guyser R, Halverson NW, Harke-Hosemann AH, Harrington NL, Harris RJ, Henning JW, Holzapfel WL, Howe D, Huang N, Irwin KD, Jeong O, Jonas M, Jones A, Korman M, Kovac J, Kubik DL, Kuhlmann S, Kuo CL, Lee AT, Lowitz AE, McMahon J, Meier J, Meyer SS, Michalik D, Montgomery J, Natoli T, Nguyen H, Noble GI, Novosad V, Padin S, Pan Z, Paschos P, Pearson J, Posada CM, Quan W, Rahlin A, Riebel D, Ruhl JE, Sayre JT, Shirokoff E, Smecher G, Stark AA, Stephen J, Story KT, Suzuki A, Tandoi C, Thompson KL, Tucker C, Vanderlinde K, Wang G, Whitehorn N, Yefremenko V, Yoon KW, Young MR. Broadband, millimeter-wave antireflection coatings for large-format, cryogenic aluminum oxide optics. APPLIED OPTICS 2020; 59:3285-3295. [PMID: 32400613 DOI: 10.1364/ao.383921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 02/25/2020] [Indexed: 06/11/2023]
Abstract
We present two prescriptions for broadband ($ {\sim} 77 - 252\;{\rm GHz} $), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements-in our case, 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of commercially available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly, while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions, then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves $ (97 \pm 2)\% $ transmittance, and the lenslet coating sample achieves $ (94 \pm 3)\% $ transmittance.
Collapse
|
31
|
Raghunathan S, Patil S, Baxter E, Benson BA, Bleem LE, Crawford TM, Holder GP, McClintock T, Reichardt CL, Varga TN, Whitehorn N, Ade PAR, Allam S, Anderson AJ, Austermann JE, Avila S, Avva JS, Bacon D, Beall JA, Bender AN, Bianchini F, Bocquet S, Brooks D, Burke DL, Carlstrom JE, Carretero J, Castander FJ, Chang CL, Chiang HC, Citron R, Costanzi M, Crites AT, da Costa LN, Desai S, Diehl HT, Dietrich JP, Dobbs MA, Doel P, Everett S, Evrard AE, Feng C, Flaugher B, Fosalba P, Frieman J, Gallicchio J, García-Bellido J, Gaztanaga E, George EM, Giannantonio T, Gilbert A, Gruendl RA, Gschwend J, Gupta N, Gutierrez G, de Haan T, Halverson NW, Harrington N, Henning JW, Hilton GC, Hollowood DL, Holzapfel WL, Honscheid K, Hrubes JD, Huang N, Hubmayr J, Irwin KD, Jeltema T, Kind MC, Knox L, Kuropatkin N, Lahav O, Lee AT, Li D, Lima M, Lowitz A, Maia MAG, Marshall JL, McMahon JJ, Melchior P, Menanteau F, Meyer SS, Miquel R, Mocanu LM, Mohr JJ, Montgomery J, Moran CC, Nadolski A, Natoli T, Nibarger JP, Noble G, Novosad V, Ogando RLC, Padin S, Plazas AA, Pryke C, Rapetti D, Romer AK, Roodman A, Rosell AC, Rozo E, Ruhl JE, Rykoff ES, Saliwanchik BR, Sanchez E, Sayre JT, Scarpine V, Schaffer KK, Schubnell M, Serrano S, Sevilla-Noarbe I, Sievers C, Smecher G, Smith M, Soares-Santos M, Stark AA, Story KT, Suchyta E, Swanson MEC, Tarle G, Tucker C, Vanderlinde K, Veach T, De Vicente J, Vieira JD, Vikram V, Wang G, Wu WLK, Yefremenko V, Zhang Y. Detection of CMB-Cluster Lensing using Polarization Data from SPTpol. PHYSICAL REVIEW LETTERS 2019; 123:181301. [PMID: 31763885 DOI: 10.1103/physrevlett.123.181301] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Indexed: 06/10/2023]
Abstract
We report the first detection of gravitational lensing due to galaxy clusters using only the polarization of the cosmic microwave background (CMB). The lensing signal is obtained using a new estimator that extracts the lensing dipole signature from stacked images formed by rotating the cluster-centered Stokes QU map cutouts along the direction of the locally measured background CMB polarization gradient. Using data from the SPTpol 500 deg^{2} survey at the locations of roughly 18 000 clusters with richness λ≥10 from the Dark Energy Survey (DES) Year-3 full galaxy cluster catalog, we detect lensing at 4.8σ. The mean stacked mass of the selected sample is found to be (1.43±0.40)×10^{14}M_{⊙} which is in good agreement with optical weak lensing based estimates using DES data and CMB-lensing based estimates using SPTpol temperature data. This measurement is a key first step for cluster cosmology with future low-noise CMB surveys, like CMB-S4, for which CMB polarization will be the primary channel for cluster lensing measurements.
Collapse
|
32
|
Matsuda F, Lowry L, Suzuki A, Aguilar Fáundez M, Arnold K, Barron D, Bianchini F, Cheung K, Chinone Y, Elleflot T, Fabbian G, Goeckner-Wald N, Hasegawa M, Kaneko D, Katayama N, Keating B, Lee AT, Navaroli M, Nishino H, Paar H, Puglisi G, Richards PL, Seibert J, Siritanasak P, Tajima O, Takatori S, Tsai C, Westbrook B. The POLARBEAR Fourier transform spectrometer calibrator and spectroscopic characterization of the POLARBEAR instrument. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:115115. [PMID: 31779409 DOI: 10.1063/1.5095160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 11/01/2019] [Indexed: 06/10/2023]
Abstract
We describe the Fourier Transform Spectrometer (FTS) used for in-field testing of the POLARBEAR receiver, an experiment located in the Atacama Desert of Chile which measures the cosmic microwave background (CMB) polarization. The POLARBEAR-FTS (PB-FTS) is a Martin-Puplett interferometer designed to couple to the Huan Tran Telescope (HTT) on which the POLARBEAR receiver is installed. The PB-FTS measured the spectral response of the POLARBEAR receiver with signal-to-noise ratio >20 for ∼69% of the focal plane detectors due to three features: a high throughput of 15.1 sr cm2, optimized optical coupling to the POLARBEAR optics using a custom designed output parabolic mirror, and a continuously modulated output polarizer. The PB-FTS parabolic mirror is designed to mimic the shape of the 2.5 m-diameter HTT primary reflector, which allows for optimum optical coupling to the POLARBEAR receiver, reducing aberrations and systematics. One polarizing grid is placed at the output of the PB-FTS and modulated via continuous rotation. This modulation allows for decomposition of the signal into different harmonics that can be used to probe potentially pernicious sources of systematic error in a polarization-sensitive instrument. The high throughput and continuous output polarizer modulation features are unique compared to other FTS calibrators used in the CMB field. In-field characterization of the POLARBEAR receiver was accomplished using the PB-FTS in April 2014. We discuss the design, construction, and operation of the PB-FTS and present the spectral characterization of the POLARBEAR receiver. We introduce future applications for the PB-FTS in the next-generation CMB experiment, the Simons Array.
Collapse
|
33
|
Levin TR, Corley DA, Jensen CD, Schottinger JE, Quinn VP, Zauber AG, Lee JK, Zhao WK, Udaltsova N, Ghai NR, Lee AT, Quesenberry CP, Fireman BH, Doubeni CA. Effects of Organized Colorectal Cancer Screening on Cancer Incidence and Mortality in a Large Community-Based Population. Gastroenterology 2018; 155:1383-1391.e5. [PMID: 30031768 PMCID: PMC6240353 DOI: 10.1053/j.gastro.2018.07.017] [Citation(s) in RCA: 321] [Impact Index Per Article: 53.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Revised: 07/02/2018] [Accepted: 07/16/2018] [Indexed: 12/15/2022]
Abstract
BACKGROUND & AIMS Little information is available on the effectiveness of organized colorectal cancer (CRC) screening on screening uptake, incidence, and mortality in community-based populations. METHODS We contrasted screening rates, age-adjusted annual CRC incidence, and incidence-based mortality rates before (baseline year 2000) and after (through 2015) implementation of organized screening outreach, from 2007 through 2008 (primarily annual fecal immunochemical testing and colonoscopy), in a large community-based population. Among screening-eligible individuals 51-75 years old, we calculated annual up-to-date status for cancer screening (by fecal test, sigmoidoscopy, or colonoscopy), CRC incidence, cancer stage distributions, and incidence-based mortality. RESULTS Initiation of organized CRC screening significantly increased the up-to-date status of screening, from 38.9% in 2000 to 82.7% in 2015 (P < .01). Higher rates of screening were associated with a 25.5% reduction in annual CRC incidence between 2000 and 2015, from 95.8 to 71.4 cases/100,000 (P < .01), and a 52.4% reduction in cancer mortality, from 30.9 to 14.7 deaths/100,000 (P < .01). Increased screening was initially associated with increased CRC incidence, due largely to greater detection of early-stage cancers, followed by decreases in cancer incidence. Advanced-stage CRC incidence rates decreased 36.2%, from 45.9 to 29.3 cases/100,000 (P < .01), and early-stage CRC incidence rates decreased 14.5%, from 48.2 to 41.2 cases/100,000 (P < .04). CONCLUSIONS Implementing an organized CRC screening program in a large community-based population rapidly increased screening participation to the ≥80% target set by national organizations. Screening rates were sustainable and associated with substantial decreases in CRC incidence and mortality within short time intervals, consistent with early detection and cancer prevention.
Collapse
|
34
|
Ghai NR, Jensen CD, Corley DA, Doubeni CA, Schottinger JE, Zauber AG, Lee AT, Contreras R, Levin TR, Lee JK, Quinn VP. Colorectal Cancer Screening Participation Among Asian Americans Overall and Subgroups in an Integrated Health Care Setting with Organized Screening. Clin Transl Gastroenterol 2018; 9:186. [PMID: 30242160 PMCID: PMC6155113 DOI: 10.1038/s41424-018-0051-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 08/01/2018] [Accepted: 08/13/2018] [Indexed: 01/01/2023] Open
Abstract
Background Screening reduces colorectal cancer deaths, but <50% of Asian Americans are screening up-to-date according to surveys, with variability across Asian subgroups. We examined colorectal cancer screening participation among Asian Americans overall and Asian subgroups in a large integrated health care system with organized screening. Methods Data were electronically accessed to characterize screening in 2016 for Asians overall and subgroups relative to the National Colorectal Cancer Roundtable target of ≥80% screening and compared with non-Hispanic whites. Screening up-to-date was defined as a colonoscopy with 10 years, a sigmoidoscopy within 5 years, or a fecal immunochemical test (FIT) completed in 2016. Results Among 436,398 patients, 69,826 (16.0%) were Asian, of whom 79.8% were screening up-to-date vs. 77.6% of non-Hispanic whites (p < 0.001). Almost all subgroups met the 80% target: Chinese (83.3%), Vietnamese (82.4%), Korean (82.1%), other Asian (80.3%), Filipino (78.7%), Asian Indian (79.6%), and Japanese (79.0%). Among Asians overall and non-Hispanic whites, 50.6% and 48.4% of members were up-to-date with screening by colonoscopy, and 28.0% and 28.2% were up-to-date by FIT, respectively. Across Asian subgroups, colonoscopy most frequently accounting for being screening up-to-date (range: 47.4–59.7%), followed by FIT (range: 21.6–31.5%). Conclusions In an organized screening setting, there were minimal differences in screening participation among Asian subgroups and almost all met the 80% screening target, despite differences in language preference. Screening test type differences across subgroups suggest possible preferences in screening modality, which can inform future research into tailored education or outreach.
Collapse
|
35
|
Shih AJ, Korsunsky I, Guttadauria B, Bhuiya T, Liew A, Khalili H, Gregersen PK, Lee AT. Abstract P2-07-09: Integrative analysis of miRNA and mRNA expression in metastatic versus non-metastatic triple negative breast cancer. Cancer Res 2018. [DOI: 10.1158/1538-7445.sabcs17-p2-07-09] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
Background: Triple Negative Breast Cancer (TNBC) is a subset of breast cancer that is difficult to treat clinically and is characterized by being estrogen receptor (ER) negative, progesterone receptor (PR) negative, and does not overexpress human epidermal growth factor receptor 2 (HER2). Patients with TNBC tend to have a worse prognosis than other breast cancer subtypes.
Methods: We obtained fifteen TNBC sample FFPE tissue blocks with corresponding plasma samples. All samples were from primary tumors; seven samples having metastasized, four samples that had not metastasized and four samples with unknown metastatic status. The total RNA was isolated from FFPE blocks using the RecoverAll Total Nucleic Acid Isolation Protocol. miRNA from plasma was isolated using Ambion's mirVANA kit. The plasma and tissue miRNAs were evaluated using the QuantStudio qPCR platform, capturing ˜750 miRNAs. The mRNA was processed using the TruSeq RNA Access kit and sequenced on the Illumina NextSeq platform. Analysis of the miRNA and mRNA individually was performed using limma and DESeq2 packages, respectively. Gene enrichment analysis of the mRNA expression was done using the GAGE package on KEGG pathways while the integrative analysis was done with sparse Canonical Correlation Analysis (sCCA) using the PMA pacakge.
Results: Analysis of plasma miRNA had four miRNAs with a significant difference in raw p-value (p < 0.05) between metastatic and non-metastatic TNBC; miRNA 708, 483-3p, 518f, and 766; in the tissue there were fifteen miRNA with p < 0.05, with one miR-872 still having significance after adjusting for multiple testing. mRNA had 33 genes being significant after multiple testing correction with several immune KEGG pathways being downregulated in metastatic samples (adjusted p < 0.05). The integrative analysis revealed five microRNA (miR-216, miR-127, miR-370, miR-382, and miR-487b) and 312 gene modules enriched in integrin (Fisher p < 10^-5) and extracellular matrix (Fisher p < 10^-6) signaling.
Conclusions: One of the circulating plasma miRNAs, miR483-3p, has been found to promote tumorigenesis, while miR581f and miR766 have not been reported in cancer to date. Further investigation into these miRNA could provide a feasible biomarker. The downregulation of immune pathways observed within the metastatic TNBC subjects implies immune evasion is of particular importance for metastasis and a targeted immunotherapy may be a viable treatment option. The integrative analysis of the miRNA and mRNA showed an enrichment in pathways previously linked to increased proliferation and chemoresistance, with an increased signal compared to either miRNA or mRNA alone.
Citation Format: Shih AJ, Korsunsky I, Guttadauria B, Bhuiya T, Liew A, Khalili H, Gregersen PK, Lee AT. Integrative analysis of miRNA and mRNA expression in metastatic versus non-metastatic triple negative breast cancer [abstract]. In: Proceedings of the 2017 San Antonio Breast Cancer Symposium; 2017 Dec 5-9; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2018;78(4 Suppl):Abstract nr P2-07-09.
Collapse
|
36
|
Corley DA, Jensen CD, Quinn VP, Doubeni CA, Zauber AG, Lee JK, Schottinger JE, Marks AR, Zhao WK, Ghai NR, Lee AT, Contreras R, Quesenberry CP, Fireman BH, Levin TR. Association Between Time to Colonoscopy After a Positive Fecal Test Result and Risk of Colorectal Cancer and Cancer Stage at Diagnosis. JAMA 2017; 317:1631-1641. [PMID: 28444278 PMCID: PMC6343838 DOI: 10.1001/jama.2017.3634] [Citation(s) in RCA: 202] [Impact Index Per Article: 28.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
IMPORTANCE The fecal immunochemical test (FIT) is commonly used for colorectal cancer screening and positive test results require follow-up colonoscopy. However, follow-up intervals vary, which may result in neoplastic progression. OBJECTIVE To evaluate time to colonoscopy after a positive FIT result and its association with risk of colorectal cancer and advanced-stage disease at diagnosis. DESIGN, SETTING, AND PARTICIPANTS Retrospective cohort study (January 1, 2010-December 31, 2014) within Kaiser Permanente Northern and Southern California. Participants were 70 124 patients aged 50 through 70 years eligible for colorectal cancer screening with a positive FIT result who had a follow-up colonoscopy. EXPOSURES Time (days) to colonoscopy after a positive FIT result. MAIN OUTCOMES AND MEASURES Risk of any colorectal cancer and advanced-stage disease (defined as stage III and IV cancer). Odds ratios (ORs) and 95% CIs were adjusted for patient demographics and baseline risk factors. RESULTS Of the 70 124 patients with positive FIT results (median age, 61 years [IQR, 55-67 years]; men, 52.7%), there were 2191 cases of any colorectal cancer and 601 cases of advanced-stage disease diagnosed. Compared with colonoscopy follow-up within 8 to 30 days (n = 27 176), there were no significant differences between follow-up at 2 months (n = 24 644), 3 months (n = 8666), 4 to 6 months (n = 5251), or 7 to 9 months (n = 1335) for risk of any colorectal cancer (cases per 1000 patients: 8-30 days, 30; 2 months, 28; 3 months, 31; 4-6 months, 31; and 7-9 months, 43) or advanced-stage disease (cases per 1000 patients: 8-30 days, 8; 2 months, 7; 3 months, 7; 4-6 months, 9; and 7-9 months, 13). Risks were significantly higher for examinations at 10 to 12 months (n = 748) for any colorectal cancer (OR, 1.48 [95% CI, 1.05-2.08]; 49 cases per 1000 patients) and advanced-stage disease (OR, 1.97 [95% CI, 1.14-3.42]; 19 cases per 1000 patients) and more than 12 months (n = 747) for any colorectal cancer (OR, 2.25 [95% CI, 1.89-2.68]; 76 cases per 1000 patients) and advanced-stage disease (OR, 3.22 [95% CI, 2.44-4.25]; 31 cases per 1000 patients). CONCLUSIONS AND RELEVANCE Among patients with a positive fecal immunochemical test result, compared with follow-up colonoscopy at 8 to 30 days, follow-up after 10 months was associated with a higher risk of colorectal cancer and more advanced-stage disease at the time of diagnosis. Further research is needed to assess whether this relationship is causal.
Collapse
|
37
|
Jensen CD, Corley DA, Quinn VP, Doubeni CA, Zauber AG, Lee JK, Zhao WK, Marks AR, Schottinger JE, Ghai NR, Lee AT, Contreras R, Klabunde CN, Quesenberry CP, Levin TR, Mysliwiec PA. Fecal Immunochemical Test Program Performance Over 4 Rounds of Annual Screening: A Retrospective Cohort Study. Ann Intern Med 2016; 164:456-63. [PMID: 26811150 PMCID: PMC4973858 DOI: 10.7326/m15-0983] [Citation(s) in RCA: 183] [Impact Index Per Article: 22.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND The fecal immunochemical test (FIT) is a common method for colorectal cancer (CRC) screening, yet its acceptability and performance over several rounds of annual testing are largely unknown. OBJECTIVE To assess FIT performance characteristics over 4 rounds of annual screening. DESIGN Retrospective cohort study. SETTING Kaiser Permanente Northern and Southern California. PATIENTS 323 349 health plan members aged 50 to 70 years on their FIT mailing date in 2007 or 2008 who completed the first round of FIT and were followed for up to 4 screening rounds. MEASUREMENTS Screening participation, FIT positivity (≥20 µg of hemoglobin/g), positive predictive values for adenoma and CRC, and FIT sensitivity for detecting CRC obtained from Kaiser Permanente electronic databases and cancer registries. RESULTS Of the patients invited for screening, 48.2% participated in round 1. Of those who remained eligible, 75.3% to 86.1% participated in subsequent rounds. Median follow-up was 4.0 years, and 32% of round 1 participants crossed over to endoscopy over 4 screening rounds-7.0% due to a positive FIT result. The FIT positivity rate (5.0%) and positive predictive values (adenoma, 51.5%; CRC, 3.4%) were highest in round 1. Overall, programmatic FIT screening detected 80.4% of patients with CRC diagnosed within 1 year of testing, including 84.5% in round 1 and 73.4% to 78.0% in subsequent rounds. LIMITATION Screening detection, rather than long-term cancer prevention, was evaluated. CONCLUSION Annual FIT screening was associated with high sensitivity for CRC, with high adherence to annual follow-up screening among initial participants. The findings indicate that annual programmatic FIT screening is feasible and effective for population-level CRC screening. PRIMARY FUNDING SOURCE National Institutes of Health.
Collapse
|
38
|
Ade PAR, Akiba Y, Anthony AE, Arnold K, Atlas M, Barron D, Boettger D, Borrill J, Chapman S, Chinone Y, Dobbs M, Elleflot T, Errard J, Fabbian G, Feng C, Flanigan D, Gilbert A, Grainger W, Halverson NW, Hasegawa M, Hattori K, Hazumi M, Holzapfel WL, Hori Y, Howard J, Hyland P, Inoue Y, Jaehnig GC, Jaffe A, Keating B, Kermish Z, Keskitalo R, Kisner T, Le Jeune M, Lee AT, Linder E, Leitch EM, Lungu M, Matsuda F, Matsumura T, Meng X, Miller NJ, Morii H, Moyerman S, Myers MJ, Navaroli M, Nishino H, Paar H, Peloton J, Quealy E, Rebeiz G, Reichardt CL, Richards PL, Ross C, Schanning I, Schenck DE, Sherwin B, Shimizu A, Shimmin C, Shimon M, Siritanasak P, Smecher G, Spieler H, Stebor N, Steinbach B, Stompor R, Suzuki A, Takakura S, Tomaru T, Wilson B, Yadav A, Zahn O. Measurement of the cosmic microwave background polarization lensing power spectrum with the POLARBEAR experiment. PHYSICAL REVIEW LETTERS 2014; 113:021301. [PMID: 25062161 DOI: 10.1103/physrevlett.113.021301] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Indexed: 06/03/2023]
Abstract
Gravitational lensing due to the large-scale distribution of matter in the cosmos distorts the primordial cosmic microwave background (CMB) and thereby induces new, small-scale B-mode polarization. This signal carries detailed information about the distribution of all the gravitating matter between the observer and CMB last scattering surface. We report the first direct evidence for polarization lensing based on purely CMB information, from using the four-point correlations of even- and odd-parity E- and B-mode polarization mapped over ∼30 square degrees of the sky measured by the POLARBEAR experiment. These data were analyzed using a blind analysis framework and checked for spurious systematic contamination using null tests and simulations. Evidence for the signal of polarization lensing and lensing B modes is found at 4.2σ (stat+sys) significance. The amplitude of matter fluctuations is measured with a precision of 27%, and is found to be consistent with the Lambda cold dark matter cosmological model. This measurement demonstrates a new technique, capable of mapping all gravitating matter in the Universe, sensitive to the sum of neutrino masses, and essential for cleaning the lensing B-mode signal in searches for primordial gravitational waves.
Collapse
|
39
|
Ade PAR, Akiba Y, Anthony AE, Arnold K, Atlas M, Barron D, Boettger D, Borrill J, Borys C, Chapman S, Chinone Y, Dobbs M, Elleflot T, Errard J, Fabbian G, Feng C, Flanigan D, Gilbert A, Grainger W, Halverson NW, Hasegawa M, Hattori K, Hazumi M, Holzapfel WL, Hori Y, Howard J, Hyland P, Inoue Y, Jaehnig GC, Jaffe A, Keating B, Kermish Z, Keskitalo R, Kisner T, Le Jeune M, Lee AT, Leitch EM, Linder E, Lungu M, Matsuda F, Matsumura T, Meng X, Miller NJ, Morii H, Moyerman S, Myers MJ, Navaroli M, Nishino H, Paar H, Peloton J, Poletti D, Quealy E, Rebeiz G, Reichardt CL, Richards PL, Ross C, Rotermund K, Schanning I, Schenck DE, Sherwin BD, Shimizu A, Shimmin C, Shimon M, Siritanasak P, Smecher G, Spieler H, Stebor N, Steinbach B, Stompor R, Suzuki A, Takakura S, Tikhomirov A, Tomaru T, Wilson B, Yadav A, Zahn O. Evidence for gravitational lensing of the cosmic microwave background polarization from cross-correlation with the cosmic infrared background. PHYSICAL REVIEW LETTERS 2014; 112:131302. [PMID: 24745402 DOI: 10.1103/physrevlett.112.131302] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2013] [Indexed: 06/03/2023]
Abstract
We reconstruct the gravitational lensing convergence signal from cosmic microwave background (CMB) polarization data taken by the Polarbear experiment and cross-correlate it with cosmic infrared background maps from the Herschel satellite. From the cross spectra, we obtain evidence for gravitational lensing of the CMB polarization at a statistical significance of 4.0σ and indication of the presence of a lensing B-mode signal at a significance of 2.3σ. We demonstrate that our results are not biased by instrumental and astrophysical systematic errors by performing null tests, checks with simulated and real data, and analytical calculations. This measurement of polarization lensing, made via the robust cross-correlation channel, not only reinforces POLARBEAR auto-correlation measurements, but also represents one of the early steps towards establishing CMB polarization lensing as a powerful new probe of cosmology and astrophysics.
Collapse
|
40
|
Hanson D, Hoover S, Crites A, Ade PAR, Aird KA, Austermann JE, Beall JA, Bender AN, Benson BA, Bleem LE, Bock JJ, Carlstrom JE, Chang CL, Chiang HC, Cho HM, Conley A, Crawford TM, de Haan T, Dobbs MA, Everett W, Gallicchio J, Gao J, George EM, Halverson NW, Harrington N, Henning JW, Hilton GC, Holder GP, Holzapfel WL, Hrubes JD, Huang N, Hubmayr J, Irwin KD, Keisler R, Knox L, Lee AT, Leitch E, Li D, Liang C, Luong-Van D, Marsden G, McMahon JJ, Mehl J, Meyer SS, Mocanu L, Montroy TE, Natoli T, Nibarger JP, Novosad V, Padin S, Pryke C, Reichardt CL, Ruhl JE, Saliwanchik BR, Sayre JT, Schaffer KK, Schulz B, Smecher G, Stark AA, Story KT, Tucker C, Vanderlinde K, Vieira JD, Viero MP, Wang G, Yefremenko V, Zahn O, Zemcov M. Detection of B-mode polarization in the cosmic microwave background with data from the South Pole Telescope. PHYSICAL REVIEW LETTERS 2013; 111:141301. [PMID: 24138230 DOI: 10.1103/physrevlett.111.141301] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2013] [Indexed: 06/02/2023]
Abstract
Gravitational lensing of the cosmic microwave background generates a curl pattern in the observed polarization. This "B-mode" signal provides a measure of the projected mass distribution over the entire observable Universe and also acts as a contaminant for the measurement of primordial gravity-wave signals. In this Letter we present the first detection of gravitational lensing B modes, using first-season data from the polarization-sensitive receiver on the South Pole Telescope (SPTpol). We construct a template for the lensing B-mode signal by combining E-mode polarization measured by SPTpol with estimates of the lensing potential from a Herschel-SPIRE map of the cosmic infrared background. We compare this template to the B modes measured directly by SPTpol, finding a nonzero correlation at 7.7σ significance. The correlation has an amplitude and scale dependence consistent with theoretical expectations, is robust with respect to analysis choices, and constitutes the first measurement of a powerful cosmological observable.
Collapse
|
41
|
Dobbs MA, Lueker M, Aird KA, Bender AN, Benson BA, Bleem LE, Carlstrom JE, Chang CL, Cho HM, Clarke J, Crawford TM, Crites AT, Flanigan DI, de Haan T, George EM, Halverson NW, Holzapfel WL, Hrubes JD, Johnson BR, Joseph J, Keisler R, Kennedy J, Kermish Z, Lanting TM, Lee AT, Leitch EM, Luong-Van D, McMahon JJ, Mehl J, Meyer SS, Montroy TE, Padin S, Plagge T, Pryke C, Richards PL, Ruhl JE, Schaffer KK, Schwan D, Shirokoff E, Spieler HG, Staniszewski Z, Stark AA, Vanderlinde K, Vieira JD, Vu C, Westbrook B, Williamson R. Frequency multiplexed superconducting quantum interference device readout of large bolometer arrays for cosmic microwave background measurements. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:073113. [PMID: 22852677 DOI: 10.1063/1.4737629] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A technological milestone for experiments employing transition edge sensor bolometers operating at sub-Kelvin temperature is the deployment of detector arrays with 100s-1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout system which has been developed for and deployed on the APEX-SZ and South Pole Telescope millimeter wavelength receivers. In this system, the detector array is divided into modules of seven detectors, and each bolometer within the module is biased with a unique ∼MHz sinusoidal carrier such that the individual bolometer signals are well separated in frequency space. The currents from all bolometers in a module are summed together and pre-amplified with superconducting quantum interference devices operating at 4 K. Room temperature electronics demodulate the carriers to recover the bolometer signals, which are digitized separately and stored to disk. This readout system contributes little noise relative to the detectors themselves, is remarkably insensitive to unwanted microphonic excitations, and provides a technology pathway to multiplexing larger numbers of sensors.
Collapse
|
42
|
Schwan D, Ade PAR, Basu K, Bender AN, Bertoldi F, Cho HM, Chon G, Clarke J, Dobbs M, Ferrusca D, Güsten R, Halverson NW, Holzapfel WL, Horellou C, Johansson D, Johnson BR, Kennedy J, Kermish Z, Kneissl R, Lanting T, Lee AT, Lueker M, Mehl J, Menten KM, Muders D, Pacaud F, Plagge T, Reichardt CL, Richards PL, Schaaf R, Schilke P, Sommer MW, Spieler H, Tucker C, Weiss A, Westbrook B, Zahn O. Invited article: millimeter-wave bolometer array receiver for the Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2011; 82:091301. [PMID: 21974566 DOI: 10.1063/1.3637460] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument is a millimeter-wave cryogenic receiver designed to observe galaxy clusters via the Sunyaev-Zel'dovich effect from the 12 m APEX telescope on the Atacama plateau in Chile. The receiver contains a focal plane of 280 superconducting transition-edge sensor (TES) bolometers instrumented with a frequency-domain multiplexed readout system. The bolometers are cooled to 280 mK via a three-stage helium sorption refrigerator and a mechanical pulse-tube cooler. Three warm mirrors, two 4 K lenses, and a horn array couple the TES bolometers to the telescope. APEX-SZ observes in a single frequency band at 150 GHz with 1' angular resolution and a 22' field-of-view, all well suited for cluster mapping. The APEX-SZ receiver has played a key role in the introduction of several new technologies including TES bolometers, the frequency-domain multiplexed readout, and the use of a pulse-tube cooler with bolometers. As a result of these new technologies, the instrument has a higher instantaneous sensitivity and covers a larger field-of-view than earlier generations of Sunyaev-Zel'dovich instruments. The TES bolometers have a median sensitivity of 890 μK(CMB)√s (NEy of 3.5 × 10(-4) √s). We have also demonstrated upgraded detectors with improved sensitivity of 530 μK(CMB)√s (NEy of 2.2 × 10(-4) √s). Since its commissioning in April 2007, APEX-SZ has been used to map 48 clusters. We describe the design of the receiver and its performance when installed on the APEX telescope.
Collapse
|
43
|
Panoutsopoulou K, Southam L, Elliott KS, Wrayner N, Zhai G, Beazley C, Thorleifsson G, Arden NK, Carr A, Chapman K, Deloukas P, Doherty M, McCaskie A, Ollier WER, Ralston SH, Spector TD, Valdes AM, Wallis GA, Wilkinson JM, Arden E, Battley K, Blackburn H, Blanco FJ, Bumpstead S, Cupples LA, Day-Williams AG, Dixon K, Doherty SA, Esko T, Evangelou E, Felson D, Gomez-Reino JJ, Gonzalez A, Gordon A, Gwilliam R, Halldorsson BV, Hauksson VB, Hofman A, Hunt SE, Ioannidis JPA, Ingvarsson T, Jonsdottir I, Jonsson H, Keen R, Kerkhof HJM, Kloppenburg MG, Koller N, Lakenberg N, Lane NE, Lee AT, Metspalu A, Meulenbelt I, Nevitt MC, O'Neill F, Parimi N, Potter SC, Rego-Perez I, Riancho JA, Sherburn K, Slagboom PE, Stefansson K, Styrkarsdottir U, Sumillera M, Swift D, Thorsteinsdottir U, Tsezou A, Uitterlinden AG, van Meurs JBJ, Watkins B, Wheeler M, Mitchell S, Zhu Y, Zmuda JM, Zeggini E, Loughlin J. Insights into the genetic architecture of osteoarthritis from stage 1 of the arcOGEN study. Ann Rheum Dis 2010; 70:864-7. [PMID: 21177295 PMCID: PMC3070286 DOI: 10.1136/ard.2010.141473] [Citation(s) in RCA: 83] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Objectives The genetic aetiology of osteoarthritis has not yet been elucidated. To enable a well-powered genome-wide association study (GWAS) for osteoarthritis, the authors have formed the arcOGEN Consortium, a UK-wide collaborative effort aiming to scan genome-wide over 7500 osteoarthritis cases in a two-stage genome-wide association scan. Here the authors report the findings of the stage 1 interim analysis. Methods The authors have performed a genome-wide association scan for knee and hip osteoarthritis in 3177 cases and 4894 population-based controls from the UK. Replication of promising signals was carried out in silico in five further scans (44 449 individuals), and de novo in 14 534 independent samples, all of European descent. Results None of the association signals the authors identified reach genome-wide levels of statistical significance, therefore stressing the need for corroboration in sample sets of a larger size. Application of analytical approaches to examine the allelic architecture of disease to the stage 1 genome-wide association scan data suggests that osteoarthritis is a highly polygenic disease with multiple risk variants conferring small effects. Conclusions Identifying loci conferring susceptibility to osteoarthritis will require large-scale sample sizes and well-defined phenotypes to minimise heterogeneity.
Collapse
|
44
|
Gorlova O, Martin JM, Rueda B, Koeleman BPC, Ying J, Teruel M, Diaz-Gallo LM, Broen JC, Vonk MC, Simeon CP, Alizadeh BZ, Coenen MJH, Voskuyl AE, Schuerwegh AJ, van Riel PLCM, Vanthuyne M, van ‘t Slot R, Italiaander A, Ophoff RA, Hunzelmann N, Fonollosa V, Ortego-Centeno N, González-Gay MA, García-Hernández FJ, González-Escribano MF, Airo P, van Laar J, Worthington J, Hesselstrand R, Smith V, De Keyser F, Houssiau F, Chee MM, Madhok R, Shiels P, Westhovens R, Kreuter A, de Baere E, Witte T, Padyukov L, Nordin A, Scorza R, Lunardi C, Lie BA, Hoffmann-Vold AM, García de la Peña P, Carreira P, Varga J, Hinchcliff M, Lee AT, Gourh P, Amos CI, Riemekasten G, Herrick A, Beretta L, Fonseca C, Denton CP, Gregersen PK, Agarwal S, Assassi S, Tan FK, Arnett FC, Radstake TRDJ, Mayes MD, Martin J. Identification of novel genetic markers associated with the clinical phenotypes of systemic sclerosis through a genome wide association strategy. Lab Invest 2010. [PMCID: PMC3007743 DOI: 10.1186/1479-5876-8-s1-o1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
45
|
Richman IB, Chung SA, Taylor KE, Kosoy R, Tian C, Ortmann WA, Nititham J, Lee AT, Rutman S, Petri M, Manzi S, Behrens TW, Gregersen PK, Seldin MF, Criswell LA. European population substructure correlates with systemic lupus erythematosus endophenotypes in North Americans of European descent. Genes Immun 2010; 11:515-21. [PMID: 19847193 PMCID: PMC3951966 DOI: 10.1038/gene.2009.80] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2009] [Revised: 09/08/2009] [Accepted: 09/15/2009] [Indexed: 01/22/2023]
Abstract
Previous work has demonstrated that Northern and Southern European ancestries are associated with specific systemic lupus erythematosus (SLE) manifestations. In this study, 1855 SLE cases of European descent were genotyped for 4965 single-nucleotide polymorphisms and principal components analysis of genotype information was used to define population substructure. The first principal component (PC1) distinguished Northern from Southern European ancestry, PC2 differentiated Eastern from Western European ancestry and PC3 delineated Ashkenazi Jewish ancestry. Compared with Northern European ancestry, Southern European ancestry was associated with autoantibody production (odds ratio (OR)=1.40, 95% confidence interval (CI) 1.07-1.83) and renal involvement (OR 1.41, 95% CI 1.06-1.87), and was protective for discoid rash (OR=0.51, 95% CI 0.32-0.82) and photosensitivity (OR=0.74, 95% CI 0.56-0.97). Both serositis (OR=1.46, 95% CI 1.12-1.89) and autoantibody production (OR=1.38, 95% CI 1.06-1.80) were associated with Western compared to Eastern European ancestry. Ashkenazi Jewish ancestry was protective against neurologic manifestations of SLE (OR=0.62, 95% CI 0.40-0.94). Homogeneous clusters of cases defined by multiple PCs demonstrated stronger phenotypic associations. Genetic ancestry may contribute to the development of SLE endophenotypes and should be accounted for in genetic studies of disease characteristics.
Collapse
|
46
|
Lanting T, Dobbs M, Spieler H, Lee AT, Yamamoto Y. Linearized superconducting quantum interference device array for high bandwidth frequency-domain readout multiplexing. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2009; 80:094501. [PMID: 19791952 DOI: 10.1063/1.3216808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We have designed and demonstrated a superconducting quantum interference device (SQUID) array linearized with cryogenic feedback. To achieve the necessary loop gain, a 300-element series array SQUID is constructed from three monolithic 100-element series arrays. A feedback resistor completes the loop from the SQUID output to the input coil. The short feedback path of this linearized SQUID array (LISA) allows for a substantially larger flux-locked loop bandwidth as compared to a SQUID flux-locked loop that includes a room temperature amplifier. The bandwidth, linearity, noise performance, and 3 Phi(0) dynamic range of the LISA are sufficient for its use in our target application: the multiplexed readout of transition-edge sensor bolometers.
Collapse
|
47
|
Laycock S, Taylor HC, Haigh C, Lee AT, Cooper GJ, Ong ACM, Robson L. A novel dephosphorylation-activated conductance in a mouse renal collecting duct cell line. Exp Physiol 2009; 94:914-27. [PMID: 19429644 DOI: 10.1113/expphysiol.2009.047753] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Autosomal dominant polycystic kidney disease (ADPKD) is one of the most common inherited renal diseases. It is associated with the progressive development of renal tubular cysts, which may subsequently lead to renal failure. Studies into the genetic basis of ADPKD have identified two genes, PKD1 and PKD2, that are mutated in ADPKD patients. The PKD1 and PKD2 genes encode for two different proteins, TRPP1 and TRPP2. Previous studies have demonstrated the presence of both TRPP1 and TRPP2 in the renal collecting duct cell line M8. The aim of the following study was to investigate the functional properties of cation currents in these cells and to examine the effect of overexpression of TRPP1 using a transgenic cell model (M7). In M8 cells, initial whole cell currents were low. However, over time there was activation of a flow-sensitive current, which was inhibited by gadolinium (I(Gd)). The I(Gd) was more selective for cations over anions, but did not discriminate between monovalent cations and was Ca2+ permeable. Activation of I(Gd) was dependent on the presence of Ca2+ and also required dephosphorylation. The protein phosphatase 2A inhibitor okadaic acid prevented activation of I(Gd), suggesting that protein phosphatase 2A plays an important role in channel activation. The properties and magnitude of I(Gd) were unaffected in M7 cells, suggesting that overexpression of TRPP1 was without effect. I(Gd) was selectively inhibited by an antibody raised against the C-terminus of TRPP2. However, its selectivity profile was different to TRPP2, suggesting that it is attributable to a TRPP2-like channel or a TRPP2-containing heteromeric channel. In conclusion, these data describe the functional identification of a novel dephosphorylation- and flow-activated TRPP2-related channel in mouse collecting duct cells.
Collapse
|
48
|
Padin S, Staniszewski Z, Keisler R, Joy M, Stark AA, Ade PAR, Aird KA, Benson BA, Bleem LE, Carlstrom JE, Chang CL, Crawford TM, Crites AT, Dobbs MA, Halverson NW, Heimsath S, Hills RE, Holzapfel WL, Lawrie C, Lee AT, Leitch EM, Leong J, Lu W, Lueker M, McMahon JJ, Meyer SS, Mohr JJ, Montroy TE, Plagge T, Pryke C, Ruhl JE, Schaffer KK, Shirokoff E, Spieler HG, Vieira JD. South Pole Telescope optics. APPLIED OPTICS 2008; 47:4418-4428. [PMID: 18716649 DOI: 10.1364/ao.47.004418] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The South Pole Telescope is a 10 m diameter, wide-field, offset Gregorian telescope with a 966-pixel, millimeter-wave, bolometer array receiver. The telescope has an unusual optical system with a cold stop around the secondary. The design emphasizes low scattering and low background loading. All the optical components except the primary are cold, and the entire beam from prime focus to the detectors is surrounded by cold absorber.
Collapse
|
49
|
Pinkett HW, Lee AT, Lum P, Locher KP, Rees DC. An inward-facing conformation of a putative metal-chelate-type ABC transporter. Science 2006; 315:373-7. [PMID: 17158291 DOI: 10.1126/science.1133488] [Citation(s) in RCA: 233] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
The crystal structure of a putative metal-chelate-type adenosine triphosphate (ATP)-binding cassette (ABC) transporter encoded by genes HI1470 and HI1471 of Haemophilus influenzae has been solved at 2.4 angstrom resolution. The permeation pathway exhibits an inward-facing conformation, in contrast to the outward-facing state previously observed for the homologous vitamin B12 importer BtuCD. Although the structures of both HI1470/1 and BtuCD have been solved in nucleotide-free states, the pairs of ABC subunits in these two structures differ by a translational shift in the plane of the membrane that coincides with a repositioning of the membrane-spanning subunits. The differences observed between these ABC transporters involve relatively modest rearrangements and may serve as structural models for inward- and outward-facing conformations relevant to the alternating access mechanism of substrate translocation.
Collapse
|
50
|
Lee AT, Li W, Liew A, Bombardier C, Weisman M, Massarotti EM, Kent J, Wolfe F, Begovich AB, Gregersen PK. The PTPN22 R620W polymorphism associates with RF positive rheumatoid arthritis in a dose-dependent manner but not with HLA-SE status. Genes Immun 2005; 6:129-33. [PMID: 15674368 DOI: 10.1038/sj.gene.6364159] [Citation(s) in RCA: 152] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We have recently described the association between rheumatoid arthritis and a coding single-nucleotide polymorphism in the intracellular protein tyrosine phosphatase, PTPN22. The disease-associated polymorphism, 1858 C/T (rs2476601), encodes an amino-acid change (R620W) in one of four SH3 domain binding sites in the PTPN22 molecule. We have now extended our initial studies to address three questions: (1) Is the association with rheumatoid arthritis limited to rheumatoid factor (RF) positive disease? (2) Does homozygosity for PTPN22 R620W substantially increase disease susceptibility? (3) Is there an interaction between PTPN22 and the rheumatoid arthritis (RA)-associated HLA-DRB1 shared epitope alleles? A total of 1413 Caucasian rheumatoid arthritis patients and 1401 Caucasian controls were genotyped. The results support the view that PTPN22 was strongly and preferentially associated with RF positive disease (OR=1.75, 95% CI 1.46-2.10, P=1.3 x 10(-9)). The PTPN22 risk allele was not significantly associated with RF negative disease (OR=1.19, 95% CI 0.92-1.53, P=0.18), although a very weak association cannot be completely excluded. There was a strong dose effect on disease risk; two copies of the PTPN22 R620W allele more than doubles the risk for RF positive RA (OR=4.57, 95% CI 2.35-8.89). There was no evidence of a genetic association between PTPN22 and HLA susceptibility alleles.
Collapse
|