26
|
Schmeh I, Kidszun A, Welk A, Schwanz T, Jansen B, Mildenberger E. Evaluation of microbiological screening in a neonatal intensive care unit to optimize empiric antibiotic use. J Hosp Infect 2018; 101:362-364. [PMID: 30292789 DOI: 10.1016/j.jhin.2018.09.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Accepted: 09/24/2018] [Indexed: 11/29/2022]
|
27
|
Jansen BHE, Disselhorst GW, Schutte T, Jansen B, Rissmann R, Richir MC, Keijsers CJPW, Vanmolkot FHM, van den Brink AM, Kramers C, Vondeling AM, Dumont GJH, de Waard-Siebinga I, Van Agtmael MA, Tichelaar J. Essential diseases in prescribing: A national Delphi study towards a core curriculum in pharmacotherapy education. Br J Clin Pharmacol 2018; 84:2645-2650. [PMID: 30076631 DOI: 10.1111/bcp.13730] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 07/18/2018] [Accepted: 07/29/2018] [Indexed: 11/28/2022] Open
Abstract
AIMS Prescribing is a core skill for junior doctors, yet 8-10% of their prescriptions contain errors. To ensure adequate training in prescribing, it is important to define the diseases for which junior doctors should be competent to prescribe. The aim of the present study was therefore to identify the essential diseases in prescribing for junior doctors. METHODS A two-round Delphi consensus study was conducted among medical specialists, general practitioners, junior doctors, pharmacists and pharmacotherapy teachers from all eight academic hospitals in the Netherlands. Using a five-point Likert scale, the participants indicated for each item on an initial questionnaire whether it should be considered an essential disease for junior doctors. The items for which ≥80% of all respondents agreed or strongly agreed were accepted as essential diseases. RESULTS Sixty-two participants completed the Delphi survey. In total, 63 of 220 items were considered to be essential diseases. CONCLUSION This is the first Delphi consensus study identifying exact conditions that junior doctors must be able to prescribe for. The essential diseases can be used for training in prescribing and assessment of junior doctors' prescribing competence.
Collapse
|
28
|
Jansen B, Hansen D, Moy R, Hanhan M, Yao Z. Gene Expression Analysis Differentiates Melanomas from Spitz Nevi. J Drugs Dermatol 2018; 17:574-576. [PMID: 29742191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
INTRODUCTION Pediatric Spitz nevi can pose significant diagnostic challenges to both clinicians and dermatopathologists when the current image-recognition based gold standard is employed. PRAME (preferentially expressed antigen in melanoma) and/or LINC (long intergeneic non-coding RNA 518) gene expression in adult patients in samples obtained non-invasively via adhesive patches differentiates primary melanomas from atypical nevi and other pigmented lesions with a NPV of over 99%, a sensitivity of 91%, and a specificity of 69%, to help clinicians rule out melanoma and the need for surgical biopsies of atypial pigmented lesions with suspicion for melanoma. Surgically obtained melanomas from adult patients show the same gene expression pattern. METHODS In this study, we investigate gene expression patterns of pigmented lesions from FFPE tissue block samples (n=23, 9 male, 14 female patients, median age 12) with a focus on differentiating Spitz nevi from melanomas in children and young adults. RESULTS PRAME levels were significantly (P less than 0.001) increased based on normalized Ct cycle counts (lower cycle counts indicate higher expression levels) in melanomas (mean Ct 33.83 + 0.54, 95% CI 32.85-34.80) when compared to Spitz nevi (mean Ct 37.21 + 0.98, 95% CI 35.41-39.01) or common nevi (mean Ct 36.94 + 0.80, 95% CI 35.47-38.40), respectively. LINC and 4 control genes showed similar expression levels in all 3 pigmented lesion groups investigated. Clinically and histopathologically complex pediatric Spitz nevi demonstrated gene expression signatures almost identical to gene expression signatures of common pediatric nevi but different from melanomas in children and young adults. DISCUSSION PRAME but not LINC gene expression can be a valuable molecular aid to differentiate melanomas from Spitz nevi, groups of pigmented lesions that can be particularly difficult to assess in children and young adults. J Drugs Dermatol. 2018;17(5):574-576.
Collapse
|
29
|
von Eiff C, Kohnen W, Becker K, Jansen B. Modern Strategies in the Prevention of Implant-Associated Infections. Int J Artif Organs 2018; 28:1146-56. [PMID: 16353121 DOI: 10.1177/039139880502801112] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The application of medical devices either for temporary or permanent use has become an indispensible part of almost all fields of medicine. However, foreign bodies are associated with a substantial risk of bacterial and fungal infections. Implant-associated infections significantly contribute to the still increasing problem of nosocomial infections. To reduce the incidence of such infections, specific guidelines providing evidence-based recommendations and comprising both technological and nontechnological strategies for prevention have been established. Strict adherence to hygienic rules during insertion or implantation of the device are aspects of particular importance. Besides such basic and indispensable aspects, the development of new materials which could withstand microbial adherence and colonization has become a major topic in recent years. Modification of surface by primarily physico-chemical methods may lead to a change in specific and unspecific interactions with microorganisms and, thus, to a reduction in microbial adherence. Medical devices made out of a material that would be ideally antiadhesive or at least colonization-resistant would be the most suitable candidates to avoid colonization and subsequent infection. However, it appears impossible to create a surface with an absolute “zero”-adherence due to thermodynamical reasons and due to the fact that a modified material surface is in vivo rapidly covered by plasma and connective tissue proteins. Therefore, another concept for the prevention of implant-associated infections involves the impregnation of devices with various antimicrobial substances such as antibiotics, antiseptics, and/or metals. In fact, already commercially available materials for clinical use such as antimicrobial catheters have been introduced, in part with considerable impact on subsequent infections. However, future studies are warranted to translate the knowledge on the pathogenesis of device-associated infections into applicable prevention strategies.
Collapse
|
30
|
Jansen B, Baart RIC. [Who does my leg belong to after amputation?; informed consent on amputation of body parts]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2018; 162:D2301. [PMID: 29493472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In the Netherlands, when body parts are amputated as part of a medical procedure the patient's consent is required if this body part is used for, or subjected to, medical tests. The patient's consent is, however, rarely obtained, when body parts are discarded as 'pathological waste'. This can raise concerns, as patients have good reasons and distinct rights to demand a different fate, such as a burial or cremation, for their amputated limb. This article analyses the legal status of an amputated body part. We conclude that, legally, the amputated part does not belong to the hospital or doctor and can therefore not be disposed of at whim, in accordance with the hospital's wishes. Doctors have an obligation to actively inform their patients of their property rights over the amputated limbs and of the alternatives to disposal that are available. Doctors might find themselves exposed to tortuous liability procedures if they dispose of amputated body parts without proper consent.
Collapse
|
31
|
Kopp C, Simonitsch I, Jilma B, Jansen B, Exner M, Speiser W, Kapiotis S, Chott A. Effect of Intradermal Tumor Necrosis Factor-α-induced Inflammation on Coagulation Factors in Dermal Vessel Endothelium. Thromb Haemost 2017. [DOI: 10.1055/s-0037-1615693] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
SummaryInflammatory mediators were shown to exert procoagulant effects on cultured human endothelial cells (EC). In the present study the effect of intradermal application of tumor necrosis factor- (TNF-) on the expression of factors involved in regulation of coagulation at the EC surface, i. e. tissue factor (TF), thrombomodulin (TM) and tissue factor pathway inhibitor (TFPI) was studied in humans in vivo. The endothelial expression of these factors was evaluated immunohistochemically in biopsies taken after intradermal application of 5000 U TNF- in 8 healthy volunteers. After 6 and 22 h biopsies were taken from the injection sites. At TNF- injected sites typical inflammatory changes, e. g. EC upregulation of adhesion molecules and accumulation of leukocytes were detected. In parallel we could document EC expression of TF, downregulation of TM and depletion of tissue factor pathway inhibitor (TFPI) in inflamed areas. Early depletion of endothelial I B at the site of inflammation after application of TNF- points to an activation of the NF- B pathway. Our data suggest that, as shown in in vitro experiments, TNF- activates the NF- B pathway and induces specific procoagulant changes of EC due to expression of TF, down-regulation of TM and depletion of TFPI in vivo in humans. This procoagulant shift in the haemostatic balance on the cell surface, caused by TNF- -induced inflammation, is likely to contribute to thrombosis associated with tissue inflammation in humans.
Collapse
|
32
|
Sligh J, Yao Z, Jansen B. An Adhesive Patch Biopsy Based Gene Expression Test to Non-invasively Differentiate Basal Cell and Squamous Cell Carcinomas from Actinic Keratoses and Other Skin Lesions of Similar Appearance. ACTA ACUST UNITED AC 2017. [DOI: 10.25251/skin.1.supp.110] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Abstract Not Available Disclosure: Study supported by DermTech.
Collapse
|
33
|
Yao Z, Moy R, Allen T, Jansen B. An Adhesive Patch-Based Skin Biopsy Device for Molecular Diagnostics and Skin Microbiome Studies. J Drugs Dermatol 2017; 16:979-986. [PMID: 29036251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
INTRODUCTION A number of diagnoses in clinical dermatology are currently histopathologically confirmed and this image recognition-based confirmation generally requires surgical biopsies. The increasing ability of molecular pathology to corroborate or correct a clinical diagnosis based on objective gene expression, mutation analysis, or molecular microbiome data is on the horizon and would be further supported by a tool or procedure to collect samples non-invasively. This study characterizes such a tool in form of a 'bladeless' adhesive patch-based skin biopsy device. METHODS The performance of this device was evaluated through a variety of complementary technologies including assessment of sample biomass, electron microscopy demonstrating the harvesting of layers of epidermal tissue, and isolation of RNA and DNA from epidermal skin samples. Samples were obtained by application of adhesive patches to the anatomical area of interest. RESULTS Biomass assessment demonstrated collection of approximately 0.3mg of skin tissue per adhesive patch and electron microscopy confirmed the nature of the harvested epidermal skin tissue. The obtained tissue samples are stored in a stable fashion on adhesive patches over a wide range of temperatures (-80oC to +60oC) and for extended periods of time (7 days or more). Total human RNA, human genomic DNA and microbiome DNA yields were 23.35 + 15.75ng, 27.72 + 20.71ng and 576.2 + 376.8pg, respectively, in skin samples obtained from combining 4 full patches collected non-invasively from the forehead of healthy volunteers. DISCUSSION The adhesive patch skin sampling procedure is well tolerated and provides robust means to obtain skin tissue, RNA, DNA, and microbiome samples without involving surgical biopsies. The non-invasively obtained skin samples can be shipped cost effectively at ambient temperature by mail or standard courier service, and are suitable for a variety of molecular analyses of the skin microbiome as well as of keratinocytes, T cells, dendritic cells, melanocytes, and other skin cells involved in the pathology of various skin conditions and conditions where the skin can serve as a surrogate target organ. <p><em>J Drugs Dermatol. 2017;16(10):979-986.</em></p>.
Collapse
|
34
|
Ferris LK, Jansen B, Ho J, Busam KJ, Gross K, Hansen DD, Alsobrook JP, Yao Z, Peck GL, Gerami P. Utility of a Noninvasive 2-Gene Molecular Assay for Cutaneous Melanoma and Effect on the Decision to Biopsy. JAMA Dermatol 2017; 153:675-680. [PMID: 28445578 DOI: 10.1001/jamadermatol.2017.0473] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance Expression of long intergenic non-protein coding RNA 518 (LINC00518) and preferentially expressed antigen in melanoma (PRAME) genes, obtained via noninvasive adhesive patch biopsy, is a sensitive and specific method for detection of cutaneous melanoma. However, the utility of this test in biopsy decisions made by dermatologists has not been evaluated. Objective To determine the utility of the pigmented lesion assay (PLA) for LINC00518/PRAME expression in decisions to biopsy a series of pigmented skin lesions. Design, Setting, and Participants In this secure web-based, multiple-reader-multiple-case study, 45 board-certified dermatologists each evaluated 60 clinical and dermoscopic images of clinically atypical pigmented lesions, first without and then with PLA gene expression information and were asked whether the lesions should be biopsied. Data were collected from March 24, 2014, through November 13, 2015. Interventions Participants were given a report for each lesion, which included the results of an assay for expression of LINC00518/PRAME and a PLA score with data on the predictive values of the information provided. Main Outcomes and Measures Biopsy sensitivity and specificity with vs without PLA data. Results Forty-five dermatologists (29 male and 16 female) performed the evaluation. After incorporating the PLA into their decision as to whether to biopsy a pigmented lesion suggestive of melanoma, dermatologists improved their mean biopsy sensitivity from 95.0% to 98.6% (P = .01); specificity increased from 32.1% to 56.9% (P < .001) with PLA data. Conclusions and Relevance The noninvasive PLA enables dermatologists to significantly improve biopsy specificity while maintaining or improving sensitivity. This result may increase the number of early melanomas biopsied and reduce the number of benign lesions biopsied, thereby improving patient outcomes and reducing health care costs.
Collapse
|
35
|
Gerami P, Yao Z, Polsky D, Jansen B, Busam K, Ho J, Martini M, Ferris LK. Development and validation of a noninvasive 2-gene molecular assay for cutaneous melanoma. J Am Acad Dermatol 2016; 76:114-120.e2. [PMID: 27707590 PMCID: PMC5599145 DOI: 10.1016/j.jaad.2016.07.038] [Citation(s) in RCA: 72] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 07/14/2016] [Accepted: 07/19/2016] [Indexed: 11/26/2022]
Abstract
Background Clinical and histopathologic assessment of pigmented skin lesions remains challenging even for experts. Differentiated and accurate noninvasive diagnostic modalities are highly desirable. Objective We sought to provide clinicians with such a tool. Methods A 2-gene classification method based on LINC00518 and preferentially expressed antigen in melanoma (PRAME) gene expression was evaluated and validated in 555 pigmented lesions (157 training and 398 validation samples) obtained noninvasively via adhesive patch biopsy. Results were compared with standard histopathologic assessment in lesions with a consensus diagnosis among 3 experienced dermatopathologists. Results In 398 validation samples (87 melanomas and 311 nonmelanomas), LINC00518 and/or PRAME detection appropriately differentiated melanoma from nonmelanoma samples with a sensitivity of 91% and a specificity of 69%. We established LINC00518 and PRAME in both adhesive patch melanoma samples and underlying formalin fixed paraffin embedded (FFPE) samples of surgically excised primary melanomas and in melanoma lymph node metastases. Limitations This technology cannot be used on mucous membranes, palms of hands, and soles of feet. Conclusions This noninvasive 2-gene pigmented lesion assay classifies pigmented lesions into melanoma and nonmelanoma groups and may serve as a tool to help with diagnostic challenges that may be inherently linked to the visual image and pattern recognition approach.
Collapse
|
36
|
Bonnechère B, Jansen B, Van Sint Jan S. Cost-effective (gaming) motion and balance devices for functional assessment: Need or hype? J Biomech 2016; 49:2561-2565. [DOI: 10.1016/j.jbiomech.2016.07.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Revised: 07/12/2016] [Accepted: 07/14/2016] [Indexed: 10/21/2022]
|
37
|
Yao Z, Allen T, Oakley M, Samons C, Garrison D, Jansen B. Analytical Characteristics of a Noninvasive Gene Expression Assay for Pigmented Skin Lesions. Assay Drug Dev Technol 2016; 14:355-63. [PMID: 27505074 DOI: 10.1089/adt.2016.724] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
We previously reported clinical performance of a novel noninvasive and quantitative PCR (qPCR)-based molecular diagnostic assay (the pigmented lesion assay; PLA) that differentiates primary cutaneous melanoma from benign pigmented skin lesions through two target gene signatures, LINC00518 (LINC) and preferentially expressed antigen in melanoma (PRAME). This study focuses on analytical characterization of this PLA, including qPCR specificity and sensitivity, optimization of RNA input in qPCR to achieve a desired diagnostic sensitivity and specificity, and analytical performance (repeatability and reproducibility) of this two-gene PLA. All target qPCRs demonstrated a good specificity (100%) and sensitivity (with a limit of detection of 1-2 copies), which allows reliable detection of gene expression changes of LINC and PRAME between melanomas and nonmelanomas. Through normalizing RNA input in qPCR, we converted the traditional gene expression analyses to a binomial detection of gene transcripts (i.e., detected or not detected). By combining the binomial qPCR results of the two genes, an improved diagnostic sensitivity (raised from 52%- 65% to 71% at 1 pg of total RNA input, and to 91% at 3 pg of total RNA input) was achieved. This two-gene PLA demonstrates a high repeatability and reproducibility (coefficient of variation <3%) and all required analytical performance characteristics for the commercial processing of clinical samples.
Collapse
|
38
|
Wolthaus J, van Asselen B, Woodings S, van Soest T, Kok J, de Prez L, Jansen B, de Pooter J, Raaymakers B. TH-CD-BRA-03: Direct Measurement of Magnetic Field Correction Factors, KQB, for Application in Future Codes of Practice for Reference Dosimetry. Med Phys 2016. [DOI: 10.1118/1.4958146] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
39
|
de Prez L, de Pooter J, Jansen B, Wolthaus J, van Asselen B, Woodings S, Soest T, Kok J, Raaymakers B. TH-CD-BRA-05: First Water Calorimetric Dw Measurement and Direct Measurement of Magnetic Field Correction Factors, KQ,B, in a 1.5 T B-Field of An MRI Linac. Med Phys 2016. [DOI: 10.1118/1.4958148] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
40
|
Omelina L, Jansen B, Bonnechère B, Oravec M, Jarmila P, Van Sint Jan S. Interaction Detection with Depth Sensing and Body Tracking Cameras in Physical Rehabilitation. Methods Inf Med 2015; 55:70-8. [PMID: 26640833 DOI: 10.3414/me14-01-0120] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2014] [Accepted: 09/17/2015] [Indexed: 11/09/2022]
Abstract
INTRODUCTION This article is part of the Focus Theme of Methods of Information in Medicine on "Methodologies, Models and Algorithms for Patients Rehabilitation". OBJECTIVES This paper presents a camera based method for identifying the patient and detecting interactions between the patient and the therapist during therapy. Detecting interactions helps to discriminate between active and passive motion of the patient as well as to estimate the accuracy of the skeletal data. METHODS Continuous face recognition is used to detect, recognize and track the patient with other people in the scene (e.g. the therapist, or a clinician). We use a method based on local binary patterns (LBP). After identifying users in the scene we identify interactions between the patient and other people. We use a depth map/point cloud for estimating the distance between two people. Our method uses the association of depth regions to user identities and computes the minimal distance between the regions. RESULTS Our results show state-of-the-art performance of real-time face recognition using low-resolution images that is sufficient to use in adaptive systems. Our proposed approach for detecting interactions shows 91.9% overall recognition accuracy what is sufficient for applications in the context of serious games. We also discuss limitations of the proposed method as well as general limitations of using depth cameras for serious games. CONCLUSIONS We introduced a new method for frame-by-frame automated identification of the patient and labeling reliable sequences of the patient's data recorded during rehabilitation (games). Our method improves automated rehabilitation systems by detecting the identity of the patient as well as of the therapist and by detecting the distance between both over time.
Collapse
|
41
|
Bonnechère B, Jansen B, Omelina L, Van Sint Jan S. Rehabilitation of neurologic patient using serious games, from theory to practice. Physiotherapy 2015. [DOI: 10.1016/j.physio.2015.03.314] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
42
|
Schmeh I, Welk A, Schwanz T, Diefenbach A, Jansen B, Mildenberger E. Is the implementation of a microbiological surveillance screening beneficial in a neonatal intensive care unit? Mol Cell Pediatr 2015. [PMCID: PMC4715031 DOI: 10.1186/2194-7791-2-s1-a17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
43
|
Bonnechère B, Jansen B, Omelina L, Degelaen M, Wermenbol V, Rooze M, Van Sint Jan S. Can serious games be incorporated with conventional treatment of children with cerebral palsy? A review. RESEARCH IN DEVELOPMENTAL DISABILITIES 2014; 35:1899-1913. [PMID: 24794289 DOI: 10.1016/j.ridd.2014.04.016] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Revised: 04/03/2014] [Accepted: 04/08/2014] [Indexed: 06/03/2023]
Abstract
The use of video games in rehabilitation is becoming more popular to clinicians. These games are embedded in off-the-shelf commercial entertainment applications or especially-developed for clinical purposes. Treatment of cerebral palsy (CP) children is a challenging task for clinicians. Lack of motivation and progress monitoring are two important factors clinicians need to deal with. The use of serious games (SG), sometimes referred to as Virtual Rehabilitation (VR), could therefore be an interesting adjuvant to conventional treatment for these patients. This is however a new discipline and many scientific issues remain to be solved. The aim of this paper is to describe available conventional treatment for CP children together with the level of evidence of each approach. A systematic review of the use of SG in rehabilitation is then conducted. 31 papers (7 randomized clinical trials, 16 cohort studies and 8 single-cases studies) were selected and analyzed, and their level of evidence compared to the conventional treatment. These studies reported outcomes for 352 patients. In summary, this review shows that it is difficult to compare those studies despite the large amount of patients. This is due to the lack of standardization in patient rehabilitation strategy and to the use of various clinical scales and scores. This non-standardization in patient follow-up between previously-published works make evidence-based conclusions difficult to obtain in order to support these techniques objectively. The use of SG for rehabilitation purposes currently meets similar issues. This paper proposes standardization strategies in order to improve treatment comparison and SG use in rehabilitation.
Collapse
|
44
|
Trippolini MA, Dijkstra PU, Jansen B, Oesch P, Geertzen JHB, Reneman MF. Reliability of clinician rated physical effort determination during functional capacity evaluation in patients with chronic musculoskeletal pain. JOURNAL OF OCCUPATIONAL REHABILITATION 2014; 24:361-9. [PMID: 23975060 PMCID: PMC4000417 DOI: 10.1007/s10926-013-9470-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
INTRODUCTION Functional capacity evaluation (FCE) can be used to make clinical decisions regarding fitness-for-work. During FCE the evaluator attempts to assess the amount of physical effort of the patient. The aim of this study is to analyze the reliability of physical effort determination using observational criteria during FCE. METHODS Twenty-one raters assessed physical effort in 18 video-recorded FCE tests independently on two occasions, 10 months apart. Physical effort was rated on a categorical four-point physical effort determination scale (PED) based on the Isernhagen criteria, and a dichotomous submaximal effort determination scale (SED). Cohen's Kappa, squared weighted Kappa and % agreement were calculated. RESULTS Kappa values for intra-rater reliability of PED and SED for all FCE tests were 0.49 and 0.68 respectively. Kappa values for inter-rater reliability of PED for all FCE tests in the first and the second session were 0.51, and 0.72, and for SED Kappa values were 0.68 and 0.77 respectively. The inter-rater reliability of PED ranged from κ = 0.02 to κ = 0.99 between FCE tests. Acceptable reliability scores (κ > 0.60, agreement ≥80 %) for each FCE test were observed in 38 % of scores for PED and 67 % for SED. On average material handling tests had a higher reliability than postural tolerance and ambulatory tests. CONCLUSION Dichotomous ratings of submaximal effort are more reliable than categorical criteria to determine physical effort in FCE tests. Regular education and training may improve the reliability of observational criteria for effort determination.
Collapse
|
45
|
De Prez L, De Pooter J, Jansen B. WE-G-17A-06: A Water Calorimeter for Use in MRI Linacs. Med Phys 2014. [DOI: 10.1118/1.4889508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
46
|
Schmidt FP, Peivandi AA, Kohnen W, Jansen B. Surgery for acquired cardiovascular disease: antiseptic treatment of contaminated vein grafts. THE JOURNAL OF CARDIOVASCULAR SURGERY 2014; 55:271-277. [PMID: 24131932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
AIM Saphenous vein grafts harvested for use as bypass conduits can be contaminated intraoperatively, e.g. by being inadvertently dropped to the floor of the operating room (OR). This study was performed to investigate microorganisms most likely contaminating vein grafts and to assess the possible efficacy of measures to treat potentially contaminated vein grafts antiseptically for further use. METHODS In a first step we determined the microbiological flora of the OR using surface cultures and cultures from intentionally dropped vein grafts. Several antiseptic agents (PVP-iodine 10%, octenidinhydrochloride 0.1%, polyhexanide 1%) were evaluated for their in vitro efficacy to disinfect artificially contaminated vein segments. The most promising antiseptic regimen was tested on veins contaminated in a real OR setting. Finally, we tested for possible alterations in mechanical properties of the veins caused by antiseptic treatment. RESULTS Coagulase-negative staphylococci where the predominant bacteria recovered from the OR with 59.9%. Antiseptic treatment with a combination of octenidine and PVP-iodine resulted in a higher rate of negative cultures than any single agent. Treatment of 50 saphenous vein grafts contaminated in the OR with the combination regimen resulted in only 3 positive cultural results within 7 days. Mechanical tear-stress testing comparing antiseptically treated vein grafts with controls showed no difference in their resistance to tear stress. CONCLUSION Antiseptic treatment of contaminated vein grafts was shown to be effective in a high percentage of cases without altering mechanical properties of grafts and may be an option for the surgeon in case of a contamination.
Collapse
|
47
|
Bonnechère B, Jansen B, Salvia P, Bouzahouene H, Sholukha V, Cornelis J, Rooze M, Van Sint Jan S. Determination of the precision and accuracy of morphological measurements using the Kinect™ sensor: comparison with standard stereophotogrammetry. ERGONOMICS 2014; 57:622-31. [PMID: 24646374 DOI: 10.1080/00140139.2014.884246] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The recent availability of the Kinect™ sensor, a low-cost Markerless Motion Capture (MMC) system, could give new and interesting insights into ergonomics (e.g. the creation of a morphological database). Extensive validation of this system is still missing. The aim of the study was to determine if the Kinect™ sensor can be used as an easy, cheap and fast tool to conduct morphology estimation. A total of 48 subjects were analysed using MMC. Results were compared with measurements obtained from a high-resolution stereophotogrammetric system, a marker-based system (MBS). Differences between MMC and MBS were found; however, these differences were systematically correlated and enabled regression equations to be obtained to correct MMC results. After correction, final results were in agreement with MBS data (p = 0.99). Results show that measurements were reproducible and precise after applying regression equations. Kinect™ sensors-based systems therefore seem to be suitable for use as fast and reliable tools to estimate morphology. Practitioner Summary: The Kinect™ sensor could eventually be used for fast morphology estimation as a body scanner. This paper presents an extensive validation of this device for anthropometric measurements in comparison to manual measurements and stereophotogrammetric devices. The accuracy is dependent on the segment studied but the reproducibility is excellent.
Collapse
|
48
|
Bonnechère B, Jansen B, Salvia P, Bouzahouene H, Omelina L, Moiseev F, Sholukha V, Cornelis J, Rooze M, Van Sint Jan S. Validity and reliability of the Kinect within functional assessment activities: comparison with standard stereophotogrammetry. Gait Posture 2013; 39:593-8. [PMID: 24269523 DOI: 10.1016/j.gaitpost.2013.09.018] [Citation(s) in RCA: 120] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2013] [Revised: 06/27/2013] [Accepted: 09/25/2013] [Indexed: 02/02/2023]
Abstract
The recent availability of the Kinect™ sensor, a cost-effective markerless motion capture system (MLS), offers interesting possibilities in clinical functional analysis and rehabilitation. However, neither validity nor reproducibility of this device is known yet. These two parameters were evaluated in this study. Forty-eight volunteers performed shoulder abduction, elbow flexion, hip abduction and knee flexion motions; the same protocol was repeated one week later to evaluate reproducibility. Movements were simultaneously recorded by the Kinect (with Microsoft Kinect SDK v.1.5) MLS and a traditional marker-based stereophotogrammetry system (MBS). Considering the MBS as reference, discrepancies between MLS and MBS were evaluated by comparing the range of motion (ROM) between both systems. MLS reproducibility was found to be statistically similar to MBS results for the four exercises. Measured ROMs however were found different between the systems.
Collapse
|
49
|
Trippolini MA, Reneman MF, Jansen B, Dijkstra PU, Geertzen JHB. Reliability and safety of functional capacity evaluation in patients with whiplash associated disorders. JOURNAL OF OCCUPATIONAL REHABILITATION 2013; 23. [PMID: 23179744 PMCID: PMC3734606 DOI: 10.1007/s10926-012-9403-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
INTRODUCTION Whiplash-associated disorders (WAD) are a burden for both individuals and society. It is recommended to evaluate patients with WAD at risk of chronification to enhance rehabilitation and promote an early return to work. In patients with low back pain (LBP), functional capacity evaluation (FCE) contributes to clinical decisions regarding fitness-for-work. FCE should have demonstrated sufficient clinimetric properties. Reliability and safety of FCE for patients with WAD is unknown. METHODS Thirty-two participants (11 females and 21 males; mean age 39.6 years) with WAD (Grade I or II) were included. The FCE consisted of 12 tests, including material handling, hand grip strength, repetitive arm movements, static arm activities, walking speed, and a 3 min step test. Overall the FCE duration was 60 min. The test-retest interval was 7 days. Interclass correlations (model 1) (ICCs) and limits of agreement (LoA) were calculated. Safety was assessed by a Pain Response Questionnaire, observation criteria and heart rate monitoring. RESULTS ICCs ranged between 0.57 (3 min step test) and 0.96 (short two-handed carry). LoA relative to mean performance ranged between 15 % (50 m walking test) and 57 % (lifting waist to overhead). Pain reactions after WAD FCE decreased within days. Observations and heart rate measurements fell within the safety criteria. CONCLUSIONS The reliability of the WAD FCE was moderate in two tests, good in five tests and excellent in five tests. Safety-criteria were fulfilled. Interpretation at the patient level should be performed with care because LoA were substantial.
Collapse
|
50
|
Jansen B, Böhme C, Schön-Hölz K, Schwartz T, Obst U, Kohnen W. Occurence of vancomycin-resistant Enterococcus faecium in patient isolates and aquatic environment during a period between 2004 and 2010. Int J Infect Dis 2012. [DOI: 10.1016/j.ijid.2012.05.579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|