26
|
Wei W, Bonvallot N, Gustafsson Å, Raffy G, Glorennec P, Krais A, Ramalho O, Le Bot B, Mandin C. Bioaccessibility and bioavailability of environmental semi-volatile organic compounds via inhalation: A review of methods and models. ENVIRONMENT INTERNATIONAL 2018; 113:202-213. [PMID: 29448239 DOI: 10.1016/j.envint.2018.01.024] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 01/22/2018] [Accepted: 01/23/2018] [Indexed: 05/06/2023]
Abstract
Semi-volatile organic compounds (SVOCs) present in indoor environments are known to cause adverse health effects through multiple routes of exposure. To assess the aggregate exposure, the bioaccessibility and bioavailability of SVOCs need to be determined. In this review, we discussed measurements of the bioaccessibility and bioavailability of SVOCs after inhalation. Published literature related to this issue is available for 2,3,7,8-tetrachlorodibenzo-p-dioxin and a few polycyclic aromatic hydrocarbons, such as benzo[a]pyrene and phenanthrene. Then, we reviewed common modeling approaches for the characterization of the gas- and particle-phase partitioning of SVOCs during inhalation. The models are based on mass transfer mechanisms as well as the structure of the respiratory system, using common computational techniques, such as computational fluid dynamics. However, the existing models are restricted to special conditions and cannot predict SVOC bioaccessibility and bioavailability in the whole respiratory system. The present review notes two main challenges for the estimation of SVOC bioaccessibility and bioavailability via inhalation in humans. First, in vitro and in vivo methods need to be developed and validated for a wide range of SVOCs. The in vitro methods should be validated with in vivo tests to evaluate human exposures to SVOCs in airborne particles. Second, modeling approaches for SVOCs need to consider the whole respiratory system. Alterations of the respiratory cycle period and human biological variability may be considered in future studies.
Collapse
|
27
|
Wei W, Mandin C, Ramalho O. Influence of indoor environmental factors on mass transfer parameters and concentrations of semi-volatile organic compounds. CHEMOSPHERE 2018; 195:223-235. [PMID: 29268180 DOI: 10.1016/j.chemosphere.2017.12.072] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Revised: 12/04/2017] [Accepted: 12/11/2017] [Indexed: 06/07/2023]
Abstract
Semi-volatile organic compounds (SVOCs) in indoor environments can partition among the gas phase, airborne particles, settled dust, and available surfaces. The mass transfer parameters of SVOCs, such as the mass transfer coefficient and the partition coefficient, are influenced by indoor environmental factors. Subsequently, indoor SVOC concentrations and thus occupant exposure can vary depending on environmental factors. In this review, the influence of six environmental factors, i.e., indoor temperature, humidity, ventilation, airborne particle concentration, source loading factor, and reactive chemistry, on the mass transfer parameters and indoor concentrations of SVOCs was analyzed and tentatively quantified. The results show that all mass transfer parameters vary depending on environmental factors. These variations are mostly characterized by empirical equations, particularly for humidity. Theoretical calculations of these parameters based on mass transfer mechanisms are available only for the emission of SVOCs from source surfaces when airborne particles are not present. All mass transfer parameters depend on the temperature. Humidity influences the partition of SVOCs among different phases and is associated with phthalate hydrolysis. Ventilation has a combined effect with the airborne particle concentration on SVOC emission and their mass transfer among different phases. Indoor chemical reactions can produce or eliminate SVOCs slowly. To better model the dynamic SVOC concentration indoors, the present review suggests studying the combined effect of environmental factors in real indoor environments. Moreover, interactions between indoor environmental factors and human activities and their influence on SVOC mass transfer processes should be considered.
Collapse
|
28
|
Derbez M, Wyart G, Le Ponner E, Ramalho O, Ribéron J, Mandin C. Indoor air quality in energy-efficient dwellings: Levels and sources of pollutants. INDOOR AIR 2018; 28:318-338. [PMID: 28960493 DOI: 10.1111/ina.12431] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Accepted: 09/21/2017] [Indexed: 05/12/2023]
Abstract
Worldwide, public policies are promoting energy-efficient buildings and accelerating the thermal renovation of existing buildings. The effects of these changes on the indoor air quality (IAQ) in these buildings remain insufficiently understood. In this context, a field study was conducted in 72 energy-efficient dwellings to describe the pollutants known to be associated with health concerns. Measured parameters included the concentrations of 19 volatile organic compounds and aldehydes, nitrogen dioxide, particulate matter (PM2.5 ), radon, temperature, and relative humidity. The air stuffiness index and night-time air exchange rate were calculated from the monitored carbon dioxide (CO2 ) concentrations. Indoor and outdoor measurements were performed at each dwelling during 1 week in each of the two following seasons: heating and non-heating. Moreover, questionnaires were completed by the occupants to characterize the building, equipment, household, and occupants' habits. Perspective on our results was provided by previous measurements made in low-energy European dwellings. Statistical comparisons with the French housing stock and a pilot study showed higher concentrations of terpenes, that is, alpha-pinene and limonene, and hexaldehyde in our study than in previous studies. Alpha-pinene and hexaldehyde are emitted by wood or wood-based products used for the construction, insulation, decoration, and furnishings of the dwellings, whereas limonene is more associated with discontinuous sources related to human activities.
Collapse
|
29
|
Pelletier M, Bonvallot N, Ramalho O, Mandin C, Wei W, Raffy G, Mercier F, Blanchard O, Le Bot B, Glorennec P. Indoor residential exposure to semivolatile organic compounds in France. ENVIRONMENT INTERNATIONAL 2017; 109:81-88. [PMID: 28950160 DOI: 10.1016/j.envint.2017.08.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Revised: 08/25/2017] [Accepted: 08/28/2017] [Indexed: 06/07/2023]
Abstract
Multiple chemicals are emitted in residential accommodation. Aggregate Daily Doses (ADD) (ng/kg-bw/d) were estimated for 32 semivolatile organic compounds (SVOCs) of different chemical families that are frequently detected in French dwellings in both air and settled dust. Daily doses were determined using steady-state models for the population, categorized into 11 age groups covering birth to age 30. Three routes of exposure were taken into account: dust ingestion, inhalation (gaseous and particulate phases) and dermal contact with the gaseous phase of air. Contamination levels were preferentially retrieved from large, nationwide representative datasets. A two-dimensional probabilistic approach was used to assess parametric uncertainty and identify the most influential factors. For children aged 2 to 3years, ADD estimates spanned orders of magnitude, with median values ranging from 8.7pg/kg-bw/d for 2,2',3,4,4'-pentabromodiphenylether (BDE 85) to 1.3μg/kg-bw/d for di-isobutyl phthalate (DiBP). Inhalation, ingestion and dermal pathway contributed at varying levels, and depending on compound, air was the dominant medium for 28 of the 32 compounds (either by inhalation or dermal contact). Indoor exposure estimate variance was mainly driven by indoor contamination variability, and secondarily by uncertainty in physical and chemical parameters. These findings lend support to the call for cumulative risk assessment of indoor SVOCs.
Collapse
|
30
|
Langer S, Ramalho O, Le Ponner E, Derbez M, Kirchner S, Mandin C. Perceived indoor air quality and its relationship to air pollutants in French dwellings. INDOOR AIR 2017; 27:1168-1176. [PMID: 28474814 DOI: 10.1111/ina.12393] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Accepted: 04/29/2017] [Indexed: 05/14/2023]
Abstract
Perception of indoor air quality (PIAQ) was evaluated in a nationwide survey of 567 French dwellings, and this survey was combined with measurements of gaseous and particulate matter (PM10 and PM2.5 ) indoor air pollutants and indoor climate parameters. The perception was assessed on a nine-grade scale by both the occupants of the dwellings and the inspectors who performed the measurements. The occupants perceived the air quality in their homes as more pleasant than the inspectors. The inspectors perceived the air quality as more unpleasant in dwellings in which the residents smoked indoors. Significant associations between PIAQ and indoor air pollutant concentrations were observed for both the inspectors and, to a lesser extent, the occupants. Introducing confounding parameters, such as building and personal characteristics, into a multivariate model suppressed most of the observed bivariate correlations and identified the tenure status of the occupants and their occupation as the parameters that most influenced their PIAQ. For the inspectors, perceived air quality was affected by the presence of smokers, the season, the type of ventilation, retrofitting, and the concentrations of acetaldehyde and acrolein.
Collapse
|
31
|
Boulanger G, Bayeux T, Mandin C, Kirchner S, Vergriette B, Pernelet-Joly V, Kopp P. Socio-economic costs of indoor air pollution: A tentative estimation for some pollutants of health interest in France. ENVIRONMENT INTERNATIONAL 2017; 104:14-24. [PMID: 28395145 DOI: 10.1016/j.envint.2017.03.025] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 03/30/2017] [Accepted: 03/31/2017] [Indexed: 05/28/2023]
Abstract
An evaluation of the socio-economic costs of indoor air pollution can facilitate the development of appropriate public policies. For the first time in France, such an evaluation was conducted for six selected pollutants: benzene, trichloroethylene, radon, carbon monoxide, particles (PM2.5 fraction), and environmental tobacco smoke (ETS). The health impacts of indoor exposure were either already available in published works or were calculated. For these calculations, two approaches were followed depending on the available data: the first followed the principles of quantitative health risk assessment, and the second was based on concepts and methods related to the health impact assessment. For both approaches, toxicological data and indoor concentrations related to each target pollutant were used. External costs resulting from mortality, morbidity (life quality loss) and production losses attributable to these health impacts were assessed. In addition, the monetary costs for the public were determined. Indoor pollution associated with the selected pollutants was estimated to have cost approximately €20 billion in France in 2004. Particles contributed the most to the total cost (75%), followed by radon. Premature death and the costs of the quality of life loss accounted for approximately 90% of the total cost. Despite the use of different methods and data, similar evaluations previously conducted in other countries yielded figures within the same order of magnitude.
Collapse
|
32
|
Szigeti T, Dunster C, Cattaneo A, Spinazzè A, Mandin C, Le Ponner E, de Oliveira Fernandes E, Ventura G, Saraga DE, Sakellaris IA, de Kluizenaar Y, Cornelissen E, Bartzis JG, Kelly FJ. Spatial and temporal variation of particulate matter characteristics within office buildings - The OFFICAIR study. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 587-588:59-67. [PMID: 28228238 DOI: 10.1016/j.scitotenv.2017.01.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Revised: 12/17/2016] [Accepted: 01/02/2017] [Indexed: 06/06/2023]
Abstract
In the frame of the OFFICAIR project, office buildings were investigated across Europe to assess how the office workers are exposed to different particulate matter (PM) characteristics (i.e. PM2.5 mass concentration, particulate oxidative potential (OP) based on ascorbate and reduced glutathione depletion, trace element concentration and total particle number concentration (PNC)) within the buildings. Two offices per building were investigated during the working hours (5 consecutive days; 8h per day) in two campaigns. Differences were observed for all parameters across the office buildings. Our results indicate that the monitoring of the PM2.5 mass concentration in different offices within a building might not reflect the spatial variation of the health relevant PM characteristics such as particulate OP or the concentration of certain trace elements (e.g., Cu, Fe), since larger differences were apparent within a building for these parameters compared to that obtained for the PM2.5 mass concentration in many cases. The temporal variation was larger for almost all PM characteristics (except for the concentration of Mn) than the spatial differences within the office buildings. These findings indicate that repeated or long-term monitoring campaigns are necessary to have information about the temporal variation of the PM characteristics. However, spatial variation in exposure levels within an office building may cause substantial differences in total exposure in the long term. We did not find strong associations between the investigated indoor activities such as printing or windows opening and the PNC values. This might be caused by the large number of factors affecting PNC indoors and outdoors.
Collapse
|
33
|
Pelletier M, Bonvallot N, Ramalho O, Blanchard O, Mercier F, Mandin C, Le Bot B, Glorennec P. Dermal absorption of semivolatile organic compounds from the gas phase: Sensitivity of exposure assessment by steady state modeling to key parameters. ENVIRONMENT INTERNATIONAL 2017; 102:106-113. [PMID: 28249739 DOI: 10.1016/j.envint.2017.02.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 02/10/2017] [Accepted: 02/13/2017] [Indexed: 06/06/2023]
Abstract
Recent research has demonstrated the importance of dermal exposure for some semivolatile organic compounds (SVOCs) present in the gas phase of indoor air. Though models for estimating dermal intake from gaseous SVOCs exist, their predictions can be subject to variations in input parameters, which can lead to large variation in exposure estimations. In this sensitivity analysis for a steady state model, we aimed to assess these variations and their determinants using probabilistic Monte Carlo sampling for 8 SVOCs from different chemical families: phthalates, bisphenols, polycyclic aromatic hydrocarbons (PAHs), organophosphorus (OPs), organochlorines (OCs), synthetic musks, polychlorinated biphenyls (PCBs) and polybromodiphenylethers (PBDEs). Indoor SVOC concentrations were found to be the most influential parameters. Both Henry's law constant (H) and octanol/water partition coefficient (Kow) uncertainty also had significant influence. While exposure media properties such as volume fraction of organic matter in the particle phase (fom-part), particle density (ρpart), concentration ([TSP]) and transport coefficient (ɣd) had a slight influence for some compounds, human parameters such as body weight (W), body surface area (A) and daily exposure (t) make a marginal or null contribution to the variance of dermal intake for a given age group. Inclusion of a parameter sensitivity analysis appears essential to reporting uncertainties in dermal exposure assessment.
Collapse
|
34
|
Wei W, Mandin C, Ramalho O. Reactivity of Semivolatile Organic Compounds with Hydroxyl Radicals, Nitrate Radicals, and Ozone in Indoor Air. INT J CHEM KINET 2017. [DOI: 10.1002/kin.21093] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
35
|
Mandin C, Trantallidi M, Cattaneo A, Canha N, Mihucz VG, Szigeti T, Mabilia R, Perreca E, Spinazzè A, Fossati S, De Kluizenaar Y, Cornelissen E, Sakellaris I, Saraga D, Hänninen O, De Oliveira Fernandes E, Ventura G, Wolkoff P, Carrer P, Bartzis J. Assessment of indoor air quality in office buildings across Europe - The OFFICAIR study. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 579:169-178. [PMID: 27866741 DOI: 10.1016/j.scitotenv.2016.10.238] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2016] [Revised: 09/27/2016] [Accepted: 10/25/2016] [Indexed: 05/27/2023]
Abstract
The European project OFFICAIR aimed to broaden the existing knowledge regarding indoor air quality (IAQ) in modern office buildings, i.e., recently built or refurbished buildings. Thirty-seven office buildings participated in the summer campaign (2012), and thirty-five participated in the winter campaign (2012-2013). Four rooms were investigated per building. The target pollutants were twelve volatile organic compounds, seven aldehydes, ozone, nitrogen dioxide and particulate matter with aerodynamic diameter <2.5μm (PM2.5). Compared to other studies in office buildings, the benzene, toluene, ethylbenzene, and xylene concentrations were lower in OFFICAIR buildings, while the α-pinene and d-limonene concentrations were higher, and the aldehyde, nitrogen dioxide and PM2.5 concentrations were of the same order of magnitude. When comparing summer and winter, significantly higher concentrations were measured in summer for formaldehyde and ozone, and in winter for benzene, α-pinene, d-limonene, and nitrogen dioxide. The terpene and 2-ethylhexanol concentrations showed heterogeneity within buildings regardless of the season. Considering the average of the summer and winter concentrations, the acetaldehyde and hexanal concentrations tended to increase by 4-5% on average with every floor level increase, and the nitrogen dioxide concentration tended to decrease by 3% on average with every floor level increase. A preliminary evaluation of IAQ in terms of potential irritative and respiratory health effects was performed. The 5-day median and maximum indoor air concentrations of formaldehyde and ozone did not exceed their respective WHO air quality guidelines, and those of acrolein, α-pinene, and d-limonene were lower than their estimated thresholds for irritative and respiratory effects. PM2.5 indoor concentrations were higher than the 24-h and annual WHO ambient air quality guidelines.
Collapse
|
36
|
Dris R, Gasperi J, Mirande C, Mandin C, Guerrouache M, Langlois V, Tassin B. A first overview of textile fibers, including microplastics, in indoor and outdoor environments. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2017; 221:453-458. [PMID: 27989388 DOI: 10.1016/j.envpol.2016.12.013] [Citation(s) in RCA: 547] [Impact Index Per Article: 78.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Revised: 12/07/2016] [Accepted: 12/09/2016] [Indexed: 05/18/2023]
Abstract
Studies about microplastics in various environments highlighted the ubiquity of anthropogenic fibers. As a follow-up of a recent study that emphasized the presence of man-made fibers in atmospheric fallout, this study is the first one to investigate fibers in indoor and outdoor air. Three different indoor sites were considered: two private apartments and one office. In parallel, the outdoor air was sampled in one site. The deposition rate of the fibers and their concentration in settled dust collected from vacuum cleaner bags were also estimated. Overall, indoor concentrations ranged between 1.0 and 60.0 fibers/m3. Outdoor concentrations are significantly lower as they range between 0.3 and 1.5 fibers/m3. The deposition rate of the fibers in indoor environments is between 1586 and 11,130 fibers/day/m2 leading to an accumulation of fibers in settled dust (190-670 fibers/mg). Regarding fiber type, 67% of the analyzed fibers in indoor environments are made of natural material, primarily cellulosic, while the remaining 33% fibers contain petrochemicals with polypropylene being predominant. Such fibers are observed in marine and continental studies dealing with microplastics. The observed fibers are supposedly too large to be inhaled but the exposure may occur through dust ingestion, particularly for young children.
Collapse
|
37
|
Wei W, Mandin C, Blanchard O, Mercier F, Pelletier M, Le Bot B, Glorennec P, Ramalho O. Predicting the gas-phase concentration of semi-volatile organic compounds from airborne particles: Application to a French nationwide survey. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 576:319-325. [PMID: 27788447 DOI: 10.1016/j.scitotenv.2016.10.074] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2016] [Revised: 09/09/2016] [Accepted: 10/10/2016] [Indexed: 06/06/2023]
Abstract
Semi-volatile organic compounds (SVOCs) partition indoors between the gas phase, airborne particles, settled dust, and other surfaces. Unknown concentrations of SVOCs in the gas phase (Cg) can be predicted from their measured concentrations in airborne particles. In previous studies, the prediction of Cg depended largely on choosing a specific equation for the calculation of the particle/gas partition coefficient. Moreover, the prediction of Cg is frequently performed at a reference temperature rather than the real indoor temperature. In this paper, a probabilistic approach based on Monte Carlo simulation was developed to predict the distribution of SVOCs' Cg from their concentrations in airborne particles at the target indoor temperature. Moreover, the distribution of the particle/gas partition coefficient of each SVOC at the target temperature was used. The approach was validated using two measured datasets in the literature: the predicted Cg from concentrations measured in airborne particles and the measured Cg were generally of the same order of magnitude. The distributions of the Cg of 66 SVOCs in the French housing stock were then predicted. The SVOCs with the highest median Cg, ranging from 1ng/m3 to >100ng/m3, included 8 phthalates (DEP, DiBP, DBP, DEHP, BBP, DMP, DiNP, and DMEP), 4 polycyclic aromatic hydrocarbons (fluorene, phenanthrene, fluoranthene, and anthracene), 2 alkylphenols (4-tert-butylphenol and 4-tert-octylphenol), 2 synthetic musks (galaxolide and tonalide), tributyl phosphate, and heptachlor. The nationwide, representative, predicted Cg values of SVOCs are frequently of the same order of magnitude in Europe and North America, whereas these Cg values in Chinese and Indian dwellings and the Cg of polybrominated diphenyl ethers in U.S. dwellings are generally higher.
Collapse
|
38
|
Collignan B, Le Ponner E, Mandin C. Relationships between indoor radon concentrations, thermal retrofit and dwelling characteristics. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY 2016; 165:124-130. [PMID: 27693653 DOI: 10.1016/j.jenvrad.2016.09.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2016] [Revised: 09/14/2016] [Accepted: 09/18/2016] [Indexed: 06/06/2023]
Abstract
A monitoring campaign was conducted on a sample of more than 3400 dwellings in Brittany, France from 2011 to 2014. The measurements were collected using one passive dosimeter per dwelling over two months during the heating season, according to the NF ISO 11665-8 (2013) standard. Moreover, building characteristics such as the period of construction, construction material, type of foundation, and thermal retrofit were determined using a questionnaire. The final data set consisted of 3233 houses with the measurement results and the questionnaire answers. Multivariate linear regression models were applied to explore the relationships between the indoor radon concentrations and building characteristics, particularly the thermal retrofit. The geometric mean of the indoor radon concentration was 155 Bq m-3 (with a geometric standard deviation of 3). The houses that had undergone a thermal retrofit had a higher average radon concentration than those that had not, which may have been due to a decrease in air permeability of the building envelope following rehabilitation work that did not systematically include proper management of the ventilation. Other building characteristics, primarily the building material and the foundation type, were associated with the indoor radon concentration. The indoor radon concentrations were higher in older houses built with granite or other stone, with a slab-on-grade foundation and without any ventilation system.
Collapse
|
39
|
Wei W, Mandin C, Blanchard O, Mercier F, Pelletier M, Le Bot B, Glorennec P, Ramalho O. Temperature dependence of the particle/gas partition coefficient: An application to predict indoor gas-phase concentrations of semi-volatile organic compounds. THE SCIENCE OF THE TOTAL ENVIRONMENT 2016; 563-564:506-512. [PMID: 27152992 DOI: 10.1016/j.scitotenv.2016.04.106] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2016] [Revised: 04/14/2016] [Accepted: 04/15/2016] [Indexed: 06/05/2023]
Abstract
The indoor gas-phase concentrations of semi-volatile organic compounds (SVOCs) can be predicted from their respective concentrations in airborne particles by applying the particle/gas partitioning equilibrium. The temperature used for partitioning is often set to 25°C. However, indoor temperatures frequently differ from this reference value. This assumption may result in errors in the predicted equilibrium gas-phase SVOC concentrations. To improve the prediction model, the temperature dependence of the particle/gas partition coefficient must be addressed. In this paper, a theoretical relationship between the particle/gas partition coefficient and temperature was developed based on the SVOC absorptive mechanism. The SVOC particle/gas partition coefficients predicted by employing the derived theoretical relationship agree well with the experimental data retrieved from the literature (R>0.93). The influence of temperature on the equilibrium gas-phase SVOC concentration was quantified by a dimensionless analysis of the derived relationship between the SVOC particle/gas partition coefficient and temperature. The predicted equilibrium gas-phase SVOC concentration decreased by between 31% and 53% when the temperature was lowered by 6°C, while it increased by up to 750% when the indoor temperature increased from 15°C to 30°C.
Collapse
|
40
|
Wei W, Boumier J, Wyart G, Ramalho O, Mandin C. Cleaning practices and cleaning products in nurseries and schools: to what extent can they impact indoor air quality? INDOOR AIR 2016; 26:517-525. [PMID: 26184913 DOI: 10.1111/ina.12236] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2015] [Accepted: 07/09/2015] [Indexed: 06/04/2023]
Abstract
In the framework of a nationwide survey on indoor air quality conducted from September 2009 to June 2011 in 310 nurseries, kindergartens, and elementary schools in all regions of France, cleaning practices and products were described through an extensive questionnaire completed on-site by expert building inspectors. The questionnaire included the cleaning frequencies and periods, cleaning techniques, whether windows were open during cleaning, and the commercial names of the products used. Analysis of the questionnaire responses showed that cleaning was generally performed daily for furniture and floors. It was performed mostly in the evening with wet mopping and with one or more windows open. Five hundred eighty-four different cleaning products were listed, among which 218 safety data sheets (SDSs) were available and analyzed. One hundred fifty-two chemical substances were identified in the SDSs. The typical substances in cleaning products included alcohols, chlorides, terpenes, aldehydes, and ethers; more than half of them are irritants. Two endocrine disruptors, 2-phenylphenol and Galaxolide, were identified in two cleaning products used every day to clean the floors, in seven kindergartens and in a nursery respectively. Eleven reactive substances containing C=C double bonds, mostly terpenes, were identified in a wide variety of cleaning products.
Collapse
|
41
|
Szigeti T, Dunster C, Cattaneo A, Cavallo D, Spinazzè A, Saraga DE, Sakellaris IA, de Kluizenaar Y, Cornelissen EJM, Hänninen O, Peltonen M, Calzolai G, Lucarelli F, Mandin C, Bartzis JG, Záray G, Kelly FJ. Oxidative potential and chemical composition of PM2.5 in office buildings across Europe - The OFFICAIR study. ENVIRONMENT INTERNATIONAL 2016; 92-93:324-33. [PMID: 27128717 DOI: 10.1016/j.envint.2016.04.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Revised: 04/08/2016] [Accepted: 04/11/2016] [Indexed: 05/05/2023]
Abstract
In the frame of the OFFICAIR project, indoor and outdoor PM2.5 samples were collected in office buildings across Europe in two sampling campaigns (summer and winter). The ability of the particles to deplete physiologically relevant antioxidants (ascorbic acid (AA), reduced glutathione (GSH)) in a synthetic respiratory tract lining fluid, i.e., oxidative potential (OP), was assessed. Furthermore, the link between particulate OP and the concentration of the PM constituents was investigated. The mean indoor PM2.5 mass concentration values were substantially lower than the related outdoor values with a mean indoor/outdoor PM2.5 mass concentration ratio of 0.62 and 0.61 for the summer and winter campaigns respectively. The OP of PM2.5 varied markedly across Europe with the highest outdoor OP(AA) m(-3) and OP(GSH) m(-3) (% antioxidant depletion/m(3) air) values obtained for Hungary, while PM2.5 collected in Finland exhibited the lowest values. Seasonal variation could be observed for both indoor and outdoor OP(AA) m(-3) and OP(GSH) m(-3) with higher mean values during winter. The indoor/outdoor OP(AA) m(-3) and OP(GSH) m(-3) ratios were less than one with 4 and 17 exceptions out of the 40 cases respectively. These results indicate that indoor air is generally less oxidatively challenging than outdoors. Correlation analysis revealed that trace elements play an important role in determining OP, in particular, the Cu content. Indoor air chemistry might affect OP since weaker correlations were obtained for indoor PM2.5. Our findings also suggest that office workers may be exposed to health relevant PM constituents to a different extent within the same building.
Collapse
|
42
|
Wei W, Mandin C, Blanchard O, Mercier F, Pelletier M, Le Bot B, Glorennec P, Ramalho O. Distributions of the particle/gas and dust/gas partition coefficients for seventy-two semi-volatile organic compounds in indoor environment. CHEMOSPHERE 2016; 153:212-9. [PMID: 27016817 DOI: 10.1016/j.chemosphere.2016.03.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Revised: 03/03/2016] [Accepted: 03/03/2016] [Indexed: 05/22/2023]
Abstract
Particle/gas and dust/gas partition coefficients (Kp and Kd) are two key parameters that address the partitioning of semi-volatile organic compounds (SVOCs) between gas-phase, airborne particles, and settled dust in indoor environment. A number of empirical equations to calculate the values of Kp and Kd have been reported in the literature. Therefore, the difficulty lies in the selection of a specific empirical equation in a given situation. In this study, we retrieved from the literature 38 empirical equations for calculating Kp and Kd values from the SVOC saturation vapor pressure and octanol/air partition coefficient. These values were calculated for 72 SVOCs: 9 phthalates, 9 polybrominated diphenyl ethers (PBDEs), 11 polychlorinated biphenyls (PCBs), 22 biocides, 14 polycyclic aromatic hydrocarbons (PAHs), 3 alkylphenols, 2 synthetic musks, tributylphosphate, and bisphenol A. The mean and median values of log10Kp or log10Kd for most SVOCs were of the same order of magnitude. The distribution of log10Kp values was fitted to either a normal distribution (for 27 SVOCs) or a log-normal distribution (for 45 SVOCs). This work provides a reference distribution of the log10Kp for 72 SVOCs, and its use may reduce the bias associated with the selection of a specific value or equation.
Collapse
|
43
|
Canha N, Mandin C, Ramalho O, Wyart G, Ribéron J, Dassonville C, Hänninen O, Almeida SM, Derbez M. Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France. INDOOR AIR 2016; 26:350-65. [PMID: 25955661 DOI: 10.1111/ina.12222] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Accepted: 05/02/2015] [Indexed: 05/15/2023]
Abstract
The aim of this study was to characterize the relationship between Indoor Air Quality (IAQ) and ventilation in French classrooms. Various parameters were measured over one school week, including volatile organic compounds, aldehydes, particulate matter (PM2.5 mass concentration and number concentration), carbon dioxide (CO2 ), air temperature, and relative humidity in 51 classrooms at 17 schools. The ventilation was characterized by several indicators, such as the air exchange rate, ventilation rate (VR), and air stuffiness index (ICONE), that are linked to indoor CO2 concentration. The influences of the season (heating or non-heating), type of school (nursery or elementary), and ventilation on the IAQ were studied. Based on the minimum value of 4.2 l/s per person required by the French legislation for mechanically ventilated classrooms, 91% of the classrooms had insufficient ventilation. The VR was significantly higher in mechanically ventilated classrooms compared with naturally ventilated rooms. The correlations between IAQ and ventilation vary according to the location of the primary source of each pollutant (outdoor vs. indoor), and for an indoor source, whether it is associated with occupant activity or continuous emission.
Collapse
|
44
|
Sakellaris IA, Saraga DE, Mandin C, Roda C, Fossati S, de Kluizenaar Y, Carrer P, Dimitroulopoulou S, Mihucz VG, Szigeti T, Hänninen O, de Oliveira Fernandes E, Bartzis JG, Bluyssen PM. Perceived Indoor Environment and Occupants' Comfort in European "Modern" Office Buildings: The OFFICAIR Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2016; 13:ijerph13050444. [PMID: 27120608 PMCID: PMC4881069 DOI: 10.3390/ijerph13050444] [Citation(s) in RCA: 100] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 04/17/2016] [Accepted: 04/19/2016] [Indexed: 11/16/2022]
Abstract
Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers' comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants' comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 "modern" office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants' comfort. The highest association with occupants' overall comfort was found for "noise", followed by "air quality", "light" and "thermal" satisfaction. Analysis of detailed parameters revealed that "noise inside the buildings" was highly associated with occupants' overall comfort. "Layout of the offices" was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building's location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.
Collapse
|
45
|
Bluyssen PM, Roda C, Mandin C, Fossati S, Carrer P, de Kluizenaar Y, Mihucz VG, de Oliveira Fernandes E, Bartzis J. Self-reported health and comfort in 'modern' office buildings: first results from the European OFFICAIR study. INDOOR AIR 2016; 26:298-317. [PMID: 25727348 DOI: 10.1111/ina.12196] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2014] [Accepted: 02/16/2015] [Indexed: 06/04/2023]
Abstract
In the European research project OFFICAIR, a procedure was developed to determine associations between characteristics of European offices and health and comfort of office workers, through a checklist and a self-administered questionnaire including environmental, physiological, psychological, and social aspects. This procedure was applied in 167 office buildings in eight European countries (Portugal, Spain, Italy, Greece, France, Hungary, the Netherlands, and Finland) during the winter of 2011-2012. About 26 735 survey invitation e-mails were sent, and 7441 office workers were included in the survey. Among respondents who rated an overall comfort less than 4 (23%), 'noise (other than from building systems)', air 'too dry', and temperature 'too variable' were the main complaints selected. An increase of perceived control over indoor climate was positively associated with the perceived indoor environment quality. Almost one-third of office workers suffered from dry eyes and headache in the last 4 weeks. Physical building characteristics were associated with occupants' overall satisfaction (acoustical solutions, mold growth, complaints procedure, cleaning activities) and health (number of occupants, lack of operable windows, presence of carpet and cleaning activities). OFFICAIR project provides a useful database to identify stressors related to indoor environmental quality and office worker's health.
Collapse
|
46
|
Teil MJ, Moreau-Guigon E, Blanchard M, Alliot F, Gasperi J, Cladière M, Mandin C, Moukhtar S, Chevreuil M. Endocrine disrupting compounds in gaseous and particulate outdoor air phases according to environmental factors. CHEMOSPHERE 2016; 146:94-104. [PMID: 26714291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 12/01/2015] [Accepted: 12/07/2015] [Indexed: 06/05/2023]
Abstract
This study investigated, for the first time in France, the spatial and temporal patterns of 55 endocrine disrupting chemicals (EDCs) in ambient air at three sites (urban, suburban and forest) under two climatic periods (warm/cold) for 2 successive years. All EDCs, except tetrabromobisphenol A (TBBPA), were encountered with various frequencies of up to 100%. Phthalate diesters (PAEs) were the most abundant chemicals with total concentrations as the sum of compounds, ranging from 10 to 100 ng m(-3) of total air, followed by alkylphenols (APs) and polycyclic aromatic hydrocarbons (PAHs), which were both approximately 1 ng m(-3). Polychlorinated biphenyl (PCBs) and bisphenol A (BPA) concentrations were notably lower (approximately 0.1 ng m(-3)). Air concentrations, depending on the considered compounds, were from 1.2 to 2 times higher in the urban than the suburban area and from 2 to 5 times higher in the urban than the forest site. PAH emissions were higher in the cold period, due to combustion processes. This finding is contrary to the other EDCs that are more abundant in the summer and governed by volatilisation. Most of the EDCs were largely distributed in the gaseous phase (>80% in the summer). The octanol/air partition coefficient (KOA) and vapour pressure (Vp) were relevant parameters for predicting EDC partitioning and direct relationships (p < 0.001) were observed i) between log K particle/gas partitioning (log Kp) and log KOA and ii) between EDC ratios in the gaseous phase and log vapour pressure (log Vp).
Collapse
|
47
|
Brown T, Dassonville C, Derbez M, Ramalho O, Kirchner S, Crump D, Mandin C. Relationships between socioeconomic and lifestyle factors and indoor air quality in French dwellings. ENVIRONMENTAL RESEARCH 2015; 140:385-396. [PMID: 25935319 DOI: 10.1016/j.envres.2015.04.012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Revised: 04/20/2015] [Accepted: 04/21/2015] [Indexed: 06/04/2023]
Abstract
BACKGROUND To date, few studies have analyzed the relationships between socioeconomic status (SES) and indoor air quality (IAQ). OBJECTIVE The aim of this study was to examine the relationships between socioeconomic and other factors and indoor air pollutant levels in French homes. METHODS The indoor air concentrations of thirty chemical, biological and physical parameters were measured over one week in a sample of 567 dwellings representative of the French housing stock between September 2003 and December 2005. Information on SES (household structure, educational attainment, income, and occupation), building characteristics, and occupants' habits and activities (smoking, cooking, cleaning, etc.) were collected through administered questionnaires. Separate stepwise linear regression models were fitted to log-transformed concentrations on SES and other factors. Logistic regression was performed on fungal contamination data. RESULTS Households with lower income were more likely to have higher indoor concentrations of formaldehyde, but lower perchloroethylene indoor concentrations. Formaldehyde indoor concentrations were also associated with newly built buildings. Smoking was associated with increasing acetaldehyde and PM2.5 levels and the risk of a positive fungal contamination index. BTEX levels were also associated with occupant density and having an attached garage. The major predictors for fungal contamination were dampness and absolute humidity. CONCLUSION These results, obtained from a large sample of dwellings, show for the first time in France the relationships between SES factors and indoor air pollutants, and believe they should be considered alongside occupant activities and building characteristics when study IAQ in homes.
Collapse
|
48
|
Brown T, Dassonville C, Derbez M, Ramalho O, Kirchner S, Crump D, Mandin C. Relationships between socioeconomic and lifestyle factors and indoor air quality in French dwellings. ENVIRONMENTAL RESEARCH 2015; 140:385-396. [PMID: 25935319 DOI: 10.1016/j.envres.2015.04012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Revised: 04/20/2015] [Accepted: 04/21/2015] [Indexed: 05/22/2023]
Abstract
BACKGROUND To date, few studies have analyzed the relationships between socioeconomic status (SES) and indoor air quality (IAQ). OBJECTIVE The aim of this study was to examine the relationships between socioeconomic and other factors and indoor air pollutant levels in French homes. METHODS The indoor air concentrations of thirty chemical, biological and physical parameters were measured over one week in a sample of 567 dwellings representative of the French housing stock between September 2003 and December 2005. Information on SES (household structure, educational attainment, income, and occupation), building characteristics, and occupants' habits and activities (smoking, cooking, cleaning, etc.) were collected through administered questionnaires. Separate stepwise linear regression models were fitted to log-transformed concentrations on SES and other factors. Logistic regression was performed on fungal contamination data. RESULTS Households with lower income were more likely to have higher indoor concentrations of formaldehyde, but lower perchloroethylene indoor concentrations. Formaldehyde indoor concentrations were also associated with newly built buildings. Smoking was associated with increasing acetaldehyde and PM2.5 levels and the risk of a positive fungal contamination index. BTEX levels were also associated with occupant density and having an attached garage. The major predictors for fungal contamination were dampness and absolute humidity. CONCLUSION These results, obtained from a large sample of dwellings, show for the first time in France the relationships between SES factors and indoor air pollutants, and believe they should be considered alongside occupant activities and building characteristics when study IAQ in homes.
Collapse
|
49
|
Mihucz VG, Szigeti T, Dunster C, Giannoni M, de Kluizenaar Y, Cattaneo A, Mandin C, Bartzis JG, Lucarelli F, Kelly FJ, Záray G. An integrated approach for the chemical characterization and oxidative potential assessment of indoor PM2.5. Microchem J 2015. [DOI: 10.1016/j.microc.2014.10.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
50
|
Nørgaard AW, Kofoed-Sørensen V, Mandin C, Ventura G, Mabilia R, Perreca E, Cattaneo A, Spinazzè A, Mihucz VG, Szigeti T, de Kluizenaar Y, Cornelissen HJM, Trantallidi M, Carrer P, Sakellaris I, Bartzis J, Wolkoff P. Ozone-initiated terpene reaction products in five European offices: replacement of a floor cleaning agent. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:13331-13339. [PMID: 25299176 DOI: 10.1021/es504106j] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Cleaning agents often emit terpenes that react rapidly with ozone. These ozone-initiated reactions, which occur in the gas-phase and on surfaces, produce a host of gaseous and particulate oxygenated compounds with possible adverse health effects in the eyes and airways. Within the European Union (EU) project OFFICAIR, common ozone-initiated reaction products were measured before and after the replacement of the regular floor cleaning agent with a preselected low emitting floor cleaning agent in four offices located in four EU countries. One reference office in a fifth country did not use any floor cleaning agent. Limonene, α-pinene, 3-carene, dihydromyrcenol, geraniol, linalool, and α-terpineol were targeted for measurement together with the common terpene oxidation products formaldehyde, 4-acetyl-1-methylcyclohexene (4-AMCH), 3-isopropenyl-6-oxo-heptanal (IPOH), 6-methyl-5-heptene-2-one, (6-MHO), 4-oxopentanal (4-OPA), and dihydrocarvone (DHC). Two-hour air samples on Tenax TA and DNPH cartridges were taken in the morning, noon, and in the afternoon and analyzed by thermal desorption combined with gas chromatography/mass spectrometry and HPLC/UV analysis, respectively. Ozone was measured in all sites. All the regular cleaning agents emitted terpenes, mainly limonene and linalool. After the replacement of the cleaning agent, substantially lower concentrations of limonene and formaldehyde were observed. Some of the oxidation product concentrations, in particular that of 4-OPA, were also reduced in line with limonene. Maximum 2 h averaged concentrations of formaldehyde, 4-AMCH, 6-MHO, and IPOH would not give rise to acute eye irritation-related symptoms in office workers; similarly, 6-AMCH, DHC and 4-OPA would not result in airflow limitation to the airways.
Collapse
|