26
|
Choi JH, Jang HI, Jang JS, Jeon SH, Joo KK, Ju K, Jung DE, Kim JG, Kim JH, Kim JY, Kim SB, Kim SY, Kim W, Kwon E, Lee DH, Lee HG, Lim IT, Moon DH, Pac MY, Seo H, Seo JW, Shin CD, Yang BS, Yoo J, Yoon SG, Yeo IS, Yu I. Search for Sub-eV Sterile Neutrinos at RENO. PHYSICAL REVIEW LETTERS 2020; 125:191801. [PMID: 33216576 DOI: 10.1103/physrevlett.125.191801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 10/08/2020] [Accepted: 10/09/2020] [Indexed: 06/11/2023]
Abstract
We report a search result for a light sterile neutrino oscillation with roughly 2200 live days of data in the RENO experiment. The search is performed by electron antineutrino (ν[over ¯]_{e}) disappearance taking place between six 2.8 GW_{th} reactors and two identical detectors located at 294 m (near) and 1383 m (far) from the center of the reactor array. A spectral comparison between near and far detectors can explore reactor ν[over ¯]_{e} oscillations to a light sterile neutrino. An observed spectral difference is found to be consistent with that of the three-flavor oscillation model. This yields limits on sin^{2}2θ_{14} in the 10^{-4}≲|Δm_{41}^{2}|≲0.5 eV^{2} region, free from reactor ν[over ¯]_{e} flux and spectrum uncertainties. The RENO result provides the most stringent limits on sterile neutrino mixing at |Δm_{41}^{2}|≲0.002 eV^{2} using the ν[over ¯]_{e} disappearance channel.
Collapse
|
27
|
Choi JH, Cho DY, Shin YS, Kim BS. Intraprocedural Flat Panel Detector Rotational Angiography and an Image Fusion Technique for Delivery of a Microcatheter into the Targeted Shunt Pouch of a Dural Arteriovenous Fistula. AJNR Am J Neuroradiol 2020; 41:1876-1878. [PMID: 32819906 DOI: 10.3174/ajnr.a6724] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Accepted: 06/03/2020] [Indexed: 11/07/2022]
Abstract
The accurate and safe delivery of a microcatheter to a targeted shunt pouch is essential for successful transvenous embolization of intracranial dural arteriovenous fistulas. However, complex anatomy and variations in head and neck veins and occluded sinuses can hinder intraprocedural microcatheter delivery. In this study, we introduce an intraprocedural flat panel detector rotational angiography and image fusion technique to aid precise navigation inside the veins and proper placement of the microcatheter in the targeted shunt pouch.
Collapse
|
28
|
Bae YU, Son Y, Kim CH, Kim KS, Hyun SH, Woo HG, Jee BA, Choi JH, Sung HK, Choi HC, Park SY, Bae JH, Doh KO, Kim JR. Embryonic Stem Cell-Derived mmu-miR-291a-3p Inhibits Cellular Senescence in Human Dermal Fibroblasts Through the TGF-β Receptor 2 Pathway. J Gerontol A Biol Sci Med Sci 2020; 74:1359-1367. [PMID: 30239625 DOI: 10.1093/gerona/gly208] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2017] [Indexed: 12/15/2022] Open
Abstract
Senescent cells accumulate in various tissues over time and contribute to tissue dysfunction and aging-associated phenotypes. Accumulating evidence suggests that cellular senescence can be inhibited through pharmacological intervention, as well as through treatment with soluble factors derived from embryonic stem cells (ESCs). In an attempt to investigate the anti-senescence factors secreted by ESCs, we analyzed mouse ESC-derived extracellular microRNAs in conditioned medium via microRNA array analysis. We selected mmu-miR-291a-3p as a putative anti-senescence factor via bioinformatics analysis. We validated its inhibitory effects on replicative, Adriamycin-induced, and ionizing radiation-induced senescence in human dermal fibroblasts. Treatment of senescent cells with mmu-miR-291a-3p decreased senescence-associated β-galactosidase activity, enhanced proliferative potential, and reduced mRNA and protein expression of TGF-β receptor 2, p53, and p21. mmu-miR-291a-3p in conditioned medium was enclosed in ESC-derived exosomes and exosomes purified from ESC conditioned medium inhibited cellular senescence. The inhibitory effects of mmu-miR-291a-3p were mediated through the TGF-β receptor 2 signaling pathway. Hsa-miR-371a-3p and hsa-miR-520e, the human homologs of mmu-miR-291a-3p, showed similar anti-senescence activity. Furthermore, mmu-miR-291a-3p accelerated the excisional skin wound healing process in aged mice. Our results indicate that the ESC-derived mmu-miR-291a-3p is a novel candidate agent that can be utilized for cell-free therapeutic intervention against aging and aging-related diseases.
Collapse
|
29
|
Suresh Kumar V, Ji SY, Zhang YT, Shojiki K, Choi JH, Kimura T, Hanada T, Katayama R, Matsuoka T. Dependence of the V/III Ratio on Indium Incorporation in InGaN Films Grown by Metalorganic Vapour Phase Epitaxy. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY 2020; 20:2979-2986. [PMID: 31635636 DOI: 10.1166/jnn.2020.17466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
InGaN epitaxial layers were grown on c-plane sapphire substrates using the metalorganic vapour phase epitaxy (MOVPE) system at 760 °C. By varying the total flow rate of group-III sources (TMI+TEG) with a fixed molar ratio of group-III sources [TMI/(TMI+TEG)], the influence of V/III ratio were investigated from 4500 to 20000. The grown N-polar InGaN layers were investigated by atomic force microscopy and it is found that the surface roughness decreases with increasing the V/III ratios. High resolution X-ray diffraction analyses show that the phase separation decreases with increasing the V/III ratios. Photoluminescence measurements reveal that the peak position of the band-edge emission shifted toward the shorter wavelength with increasing the V/III ratios. Reciprocal space mapping (RSM) analyses were carried out on InGaN films. At low V/III ratio, the phase separation can be detected in InGaN films.
Collapse
|
30
|
Faruqui N, Kummrow A, Fu B, Divieto C, Rojas F, Kisulu F, Cavalcante JJV, Wang J, Campbell J, Martins JL, Choi JH, Sassi MP, Zucco M, Vonsky M, Vessillier S, Zou S, Fujii SI, Ryadnov MG. Cellular Metrology: Scoping for a Value Proposition in Extra- and Intracellular Measurements. Front Bioeng Biotechnol 2020; 7:456. [PMID: 31993416 PMCID: PMC6970939 DOI: 10.3389/fbioe.2019.00456] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Accepted: 12/19/2019] [Indexed: 12/23/2022] Open
Abstract
The symptomatic irreproducibility of data in biomedicine and biotechnology prompts the need for higher order measurements of cells in their native and near-native environments. Such measurements may support the adoption of new technologies as well as the development of research programs across different sectors including healthcare and clinic, environmental control and national security. With an increasing demand for reliable cell-based products and services, cellular metrology is poised to help address current and emerging measurement challenges faced by end-users. However, metrological foundations in cell analysis remain sparse and significant advances are necessary to keep pace with the needs of modern medicine and industry. Herein we discuss a role of metrology in cell and cell-related R&D activities to underpin growing international measurement capabilities. Relevant measurands are outlined and the lack of reference methods and materials, particularly those based on functional cell responses in native environments, is highlighted. The status quo and current challenges in cellular measurements are discussed in the light of metrological traceability in cell analysis and applications (e.g., a functional cell count). An emphasis is made on the consistency of measurement results independent of the analytical platform used, high confidence in data quality vs. quantity, scale of measurements and issues of building infrastructure for end-users.
Collapse
|
31
|
Kim HY, Kim KH, Choi JH. P1443 Sex differences of coronary physiology can be justified by fractional myocardial mass. Eur Heart J Cardiovasc Imaging 2020. [DOI: 10.1093/ehjci/jez319.871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background Women has lower prevalence of coronary artery disease but has higher mortality from acute myocardial infarction. The gender difference in the anatomical-physiological relationship may elucidate the gender difference in the clinical presentation of coronary artery disease.
Purpose
We hypothesized that the gender difference in the anatomical-physiological relationship may elucidate the gender difference in the clinical presentation of coronary artery disease.
Background Women has lower prevalence of coronary artery disease but has higher mortality from acute myocardial infarction. The gender difference in the anatomical-physiological relationship may elucidate the gender difference in the clinical presentation of coronary artery disease.
Methods In this multicenter registry, 482 patients who underwent coronary CT angiography and fractional flow reserve (FFR) measurement were enrolled. Fractional myocardial mass (FMM, a vessel-specific amount of myocardium) and %FMM (fraction of FMM to whole myocardial mass) was measured in major coronary arteries and branches. FFR and quantitative coronary angiography (QCA) were interrogated in the subset of 772 vessels. The severity of physiological or anatomical stenosis was assessed by FFR and diameter stenosis (DS), respectively.
Results In the analysis of all major epicardial arteries (N = 3,833), FMM was lower in women compared to men (p < 0.01, all), but %FMM was similar between women and men (p = NS, all). Among physiologically assessed 772 vessels, compared to men (N = 587), vessels of women (N = 185) showed smaller dimension (reference diameter (RD) = 2.90 ± 0.65 vs 3.14 ± 0.69 mm, minimal luminal diameter (MLD) = 1.30±.0.57 vs 1.40 ± 0.57 mm (p < 0.05, all), similar severity of stenosis (DS = 55% vs 55% p = NS), and higher FFR (0.81 ± 0.13 vs 0.78 ± 0.15, p < 0.001). In subgroup analysis according to the tertiary categories of DS, RD, and MLD, vessels of women showed higher FFR and lower FMM. Generalized estimating equations modeling demonstrated that gender, DS, RD, MLD, and location in left anterior descending artery were not (p = NS, all) but FMM/MLD were significant predictors for FFR ≤ 0.80 (p = 0.021).
Conclusions
Compared to men, coronary arteries of women are smaller and supply smaller amount of myocardium even after adjusting for vessel size, which may explain overall higher FFR value of women. This gender difference in anatomical-physiological relationship may explain the gender difference in the clinical coronary artery disease.
Abstract P1443 Figure.
Collapse
|
32
|
Kim HY, Choi JH, Kim KH, Kim SM. 1175 Comparison of fractional myocardial mass, a vessel-specific myocardial mass-at-risk, with coronary angiographic scoring systems for predicting myocardial ischemia. Eur Heart J Cardiovasc Imaging 2020. [DOI: 10.1093/ehjci/jez319.674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Aims The burden of coronary artery disease has been assessed by various semi-quantitative angiographic scores, which are frequently different each other. A non-invasive and quantitative modality may substitute angiographic sores for prognostic implication and decision of revascularization strategy. We compared fractional myocardial mass (FMM) with angiographic scores for predicting myocardial ischemia.
Methods In this multicenter registry, 411 patients who underwent coronary computed tomography angiography (CCTA) were followed by invasive coronary angiography and FFR measurement. CCTA–derived %FMM with diameter stenosis ≥70% (%FMM-70) or ≥50% (%FMM-50) were compared with 9 angiographic scores (APPROACH, Duke Jeopardy, BARI, CASS, SYNTAX, Jenkins, BCIS-1, Leaman, Modified Duke) and were tested regarding their performance for predicting FFR ≤ 0.80. Predictive performance of %FMM or angiographic scores for FFR ≤ 0.80 established in derivation cohort (N = 250) and tested in validation cohort (N = 161).
Results The performance of %FMM-70 and %FMM-50 were similar to most angiographic scores (%FMM-70, c-statistics = 0.76; %FMM-50, 0.71; angiographic scores, 0.68 – 0.79). The frequency of FFR ≤ 0.80 increased consistently according to %FMM-70, %FMM-50, and all angiographic scores (p < 0.001, all). The optimal cutoff of %FMM-50 and %FMM-70 for FFR ≤ 0.80 were ≥34.5% and ≥9.8%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of %FMM-50 were 83%, 56%, 73%, 70%, 72%, and of %FMM-70 were 72%, 78%, 75%, 75%, and 75% using these cutoffs. Validation cohort showed consistent results.
Conclusion %FMM correlated well with angiographic scores and had a potential to be used as a non-invasive alternative to the angiographic scores. The integration of the severity of stenosis and the amount of subtended myocardium may improve the detection of clinically significant coronary artery stenosis.
Abstract 1175 Figure. FMM vs angiographic score
Collapse
|
33
|
Cheon S, Lee WW, Park WI, Jung JY, Choi JH, Choi DG, Jeon S, Jeong JH, Lee J. Fabrication of arrangement-controlled and vertically grown ZnO nanorods by metal nanotransfer printing. J IND ENG CHEM 2020. [DOI: 10.1016/j.jiec.2019.09.029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
34
|
Jung JM, Jung CJ, Lee WJ, Won CH, Lee MW, Choi JH, Chang SE. Topically applied treatments for external genital warts in nonimmunocompromised patients: a systematic review and network meta-analysis. Br J Dermatol 2019; 183:24-36. [PMID: 31675442 DOI: 10.1111/bjd.18638] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/24/2019] [Indexed: 01/22/2023]
Abstract
Selecting a topical treatment from among the numerous topical agents for external genital warts remains challenging without clear evidence. Our aim was to evaluate comparatively the efficacy and safety of topical agents for external genital warts using a network meta-analysis. We included all randomized controlled trials that evaluated any topically applied treatment for external genital warts. Using the R package netmeta, network meta-analyses were performed with a frequentist approach. We identified 41 relevant studies comprising 6371 patients. Among conventional agents, podophyllotoxin 0·5% solution (odds ratio 1·94, 95% confidence interval 1·02-3·71) was significantly more efficacious than imiquimod 5% cream for lesion clearance; however, it was associated with a higher overall adverse event rate. Sinecatechins 15% ointment (odds ratio 0·21, 95% confidence interval 0·12-0·34) was significantly less efficacious than imiquimod 5% cream. Idoxuridine, polyhexamethylene biguanide, cidofovir and SB206 showed comparable therapeutic efficacies with conventional therapies. None of the treatments were significantly different from each other with respect to recurrence, patients with severe adverse events, or patients who withdrew because of treatment-related adverse events. Conventional modalities were efficacious and well tolerated, although each of them had their advantages and disadvantages. Additional efficacy and safety studies are warranted for unconventional agents.
Collapse
|
35
|
Choi JH, Han S, Kemp MG. Detection of the small oligonucleotide products of nucleotide excision repair in UVB-irradiated human skin. DNA Repair (Amst) 2019; 86:102766. [PMID: 31838380 DOI: 10.1016/j.dnarep.2019.102766] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 10/26/2019] [Accepted: 12/04/2019] [Indexed: 11/29/2022]
Abstract
UVB radiation results in the formation of potentially mutagenic photoproducts in the DNA of epidermal skin cells. In vitro approaches have demonstrated that the nucleotide excision repair (NER) machinery removes UV photoproducts from DNA in the form of small (∼30-nt-long), excised, damage-containing DNA oligonucleotides (sedDNAs). Though this process presumably takes place in human skin exposed to UVB radiation, sedDNAs have not previously been detected in human skin. Using surgically discarded human skin, we have optimized the detection of the sedDNA products of NER from small amounts of human epidermal tissue ex vivo within minutes of UVB exposure and after UVB doses that normally lead to minimal erythema. Moreover, sedDNA generation was inhibited by treatment of skin explants with spironolactone, which depletes the epidermis of the essential NER protein XPB to mimic the skin of xeroderma pigmentosum patients. Time course experiments revealed that a partially degraded form of the sedDNAs could be readily detected even 12 hours following UVB exposure, which indicates that these repair products are relatively stable in human skin epidermis. Together, these data suggest that sedDNA detection may be a useful assay for determining how genetic, environmental, and other factors influence NER activity in human skin epidermis and whether abnormal sedDNA processing contributes to photosensitive skin disorders.
Collapse
|
36
|
Cho DY, Kim BS, Choi JH, Park YK, Shin YS. The Fate of Unruptured Intracranial Vertebrobasilar Dissecting Aneurysm with Brain Stem Compression According to Different Treatment Modalities. AJNR Am J Neuroradiol 2019; 40:1924-1931. [PMID: 31601577 DOI: 10.3174/ajnr.a6252] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Accepted: 08/20/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND AND PURPOSE Unruptured intracranial vertebrobasilar dissecting aneurysms with brain stem compression are difficult to treat. In the present study, the clinical and radiologic outcomes of unruptured intracranial vertebrobasilar dissecting aneurysms with brain stem compression based on different treatment modalities were evaluated. MATERIALS AND METHODS This study included 28 patients with unruptured intracranial vertebrobasilar dissecting aneurysms with brain stem compression treated from January 2009 to December 2017. Treatment methods were observation (n = 6), stent-assisted coil embolization (n = 9), parent artery occlusion (n = 6), and flow diversion (n = 7). The data of baseline characteristics, change of aneurysm size, retreatment rate, stroke occurrence, and alteration of the mRS score were obtained from retrospective chart review. RESULTS The initial size of dissecting aneurysms was largest in the flow diversion group (22.5 ± 7.7 mm), followed by parent artery occlusion (20.3 ± 8.4 mm), stent-assisted coil embolization (11.7 ± 2.2 mm), and observation (17.8 ± 5.5 mm; P = .01) groups. The reduction rate of aneurysm size was highest in the parent artery occlusion group (26.7 ± 32.1%), followed by flow diversion (14.1% ± 28.7%), stent-assisted coil embolization (-17.9 ± 30.3%), and observation (-31.5 ± 30.8%; P = .007) groups. Additional treatment was needed in the observation (4/6, 66.7%) and stent-assisted coil embolization (3/9, 33.3%; P = .017) groups. Improvement of the mRS score on follow-up was observed in the flow diversion (6/7, 85.7%) and parent artery occlusion (4/6, 66.7%) groups but not in the stent-assisted coil embolization and observation groups. A worsened mRS score was most common in the observation group (4/6, 66.7%), followed by stent-assisted coil embolization (3/9, 33.3%), parent artery occlusion (2/6, 33.3%), and flow diversion (0/7, 0%) groups. CONCLUSIONS When treating intracranial vertebrobasilar dissecting aneurysms with brain stem compression, parent artery occlusion and flow diversion should be considered to reduce aneurysm size and improve the mRS score.
Collapse
|
37
|
Choe JC, Cha KS, Shin JY, Ahn J, Park JS, Lee HW, Oh JH, Choi JH, Lee HC, Hong TJ. 3334Updated meta-analysis of biodegradable polymer drug-eluting stent versus second-generation durable polymer drug-eluting stent implantations. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz745.0086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Data regarding clinical outcomes of biodegradable polymer drug-eluting stent (BP-DES) versus second-generation durable polymer drug-eluting stent (DP-DES) in patients undergoing percutaneous coronary intervention (PCI) are inconclusive.
Purpose
We aimed to perform a meta-analysis to investigate the clinical outcomes of BP-DES compared with second-generation DP-DES in patients who have undergone PCI.
Methods
We searched PubMed, MEDLINE, EMBASE, and Cochrane databases through January 2019 for randomized controlled trials comparing BP-DES with second-generation DP-DES in patients treated with PCI. All-cause death, cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), target lesion revascularization (TLR), definite/probable stent thrombosis (ST) were compared between the groups. Additionally, a landmark analysis with the landmark set at 1 year and a subgroup analysis according to stent characteristics were performed.
Results
Data from 23 trials including 28802 randomized patients were analyzed. At a median follow up of 3.1 years, no significant differences were found in terms of all-cause death (odds ratio [OR] 1.05, 95% confidence interval [CI] 0.95–1.16), cardiac death (OR 1.01, 95% CI 0.87–1.17), MI (OR 0.92, 95% CI 0.82–1.03), TVR (OR 0.97, 95% CI 0.86–1.11), TLR (OR 0.97, 95% CI 0.85–1.11), and definite/probable ST (OR 0.86, 95% CI 0.70–1.07) between the groups. Landmark analysis showed that there were similar risks in all-cause death (OR 1.04, 95% CI 0.93–1.17), cardiac death (OR 1.11, 95% CI 0.92–1.36), MI (OR 0.94, 95% CI 0.79–1.13), TVR (OR 0.95, 95% CI 0.73–1.23), TLR (OR 1.00, 95% CI 0.80–1.24), and definite/probable ST (OR 0.92, 95% CI 0.67–1.28) between the groups. The similar tendency of any study endpoints between the groups was consistent in the subgroup, including stent platform (stainless steel vs. alloy), the drug coating distribution (abluminal vs. circumferential), the polymer degradation period (<6 months vs. >6 months), or the drug release duration (<6 months vs. >6 months) of BP-DES, or the DAPT duration (≥6 months vs. ≥12 months). However, the uses of BP-DES with sirolimus-eluting (OR 0.84, 95% CI 0.72–0.98) or ultrathin strut (defined as <70μm; OR 0.81, 95% CI 0.68–0.97) were predictive for lower risk of MI.
Clinical outcomes
Conclusions
In our updated meta-analysis, BP-DES implantation was associated with comparable clinical outcomes compared with second-generation DP-DES implantation. However, PCI with ultrathin biodegradable polymer sirolimus-eluting stent could reduce the risk of MI.
Collapse
|
38
|
Choe JC, Cha KS, Shin JY, Ahn J, Park JS, Lee HW, Oh JH, Choi JH, Lee HC, Hong TJ. P2799Long-term outcomes after percutaneous coronary intervention with biodegradable polymer drug-eluting stent versus second-generation durable polymer drug-eluting stent: evidence from a meta-analysis. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz748.1112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
The true benefit of biodegradable polymer drug-eluting stent (BP-DES) over second-generation durable polymer drug-eluting stent (DP-DES) expected to be represented during late period of follow-up after percutaneous coronary intervention (PCI), but prior meta-analysis only evaluated short-term outcomes.
Purpose
We aimed to compare the long-term clinical outcomes after PCI with BP-DES versus second-generation DP-DES by a meta-analysis of randomized controlled trials.
Methods
Randomized controlled trials comparing BP-DES with second-generation DP-DES implantations were searched through PubMed, MEDLINE, EMBASE, and Cochrane databases. All-cause death, cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), target lesion revascularization (TLR), and definite/probable stent thrombosis (ST) were compared between the groups. In addition, a landmark analysis with the landmark set at 1-year and a subgroup analysis based on stent characteristics were performed.
Results
Fifteen trials that included a total of 21311 randomized patients with at least 2 years follow-up were analyzed. At a median follow-up of 4.2 years, no significant differences in the risks of all-cause death (odds ratio [OR] 1.03, 95% confidence interval [CI] 0.94–1.14), cardiac death (OR 1.03, 95% CI 0.88–1.20), MI (OR 0.90, 95% CI 0.79–1.01), TVR (OR 0.96, 95% CI 0.82–1.12), TLR (OR 0.97, 95% CI 0.85–1.11), and definite/probable ST (OR 0.84, 95% CI 0.67–1.05) were found between the groups. In the 1-year landmark analysis, the rates of all-cause death (OR 1.04, 95% CI 0.93–1.17), cardiac death (OR 1.11, 95% CI 0.92–1.36), MI (OR 0.94, 95% CI 0.79–1.13), TVR (OR 0.95, 95% CI 0.73–1.23), TLR (OR 1.00, 95% CI 0.80–1.24), and definite/probable ST (OR 0.94, 95% CI 0.67–1.31) were similar between the groups. There were comparable rates of any study endpoints between the groups regardless of stent platform (stainless steel vs. alloy), the polymer degradation period (<6 months vs. >6 months) or the drug release duration (<6 months vs. >6 months) of BP-DES, or the DAPT duration (≥6 months vs. ≥12 months). However, the use of BP-DES with sirolimus eluting (OR 0.82, 95% CI 0.70–0.97), circumferential drug distribution (OR 0.79, 95% CI 0.65–0.96), thin strut (defined as <100μm; OR 0.83, 95% CI 0.70–0.97), or ultrathin strut (defined as <70μm; OR 0.78, 95% CI 0.64–0.94) were associated with lower rates of MI than did second-generation DP-DES. Moreover, BP-DES with circumferential drug distribution (OR 0.82, 95% CI 0.69–0.98) was predictive for reduced rates of TVR.
Clinical outcomes
Conclusions
In this meta-analysis, long-term clinical outcomes were equivalent between BP-DES and second-generation DP-DES implantations. However, among BP-DESs, the improved risks of MI in those with sirolimus eluting, circumferential drug distribution, thin strut, or ultrathin strut and decreased rates of TVR in those with circumferential drug distribution were noted.
Collapse
|
39
|
Shin SH, Shin SH, Choi JH, Lee J, Choi DG, Jeong JH, Ju BK, Jung JY. Dual nanotransfer printing for complementary plasmonic biosensors. NANOTECHNOLOGY 2019; 30:385302. [PMID: 31234162 DOI: 10.1088/1361-6528/ab2c10] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
One of the main challenges in the widespread utilization of localized plasmon resonance-based biosensors is the fabrication of large-area and low-cost plasmonic nanostructures. In this work, we fabricated large-area and low-cost complementary plasmonic biosensors such as nanohole and nanodisk arrays using dual nanotransfer printing (NTP) with a single metal deposition and a single reusable mold. The suspended nanohole arrays and the suspended nanodisk arrays were fabricated using the subsequent dry etching process. We confirmed a maximum enhancement in bulk sensitivity in experiments and simulations by controlling the vertical and lateral etching depths of the dielectric layer underneath the gold (Au) nanohole and nanodisk arrays. Furthermore, we show that the surface sensitivity evaluated by atomic layer deposition of aluminum oxide increased because appropriate vertical and lateral etching depths allow the target analyte to access the additional near-field formed at the bottom of the Au nanostructure. The dual NTP method provides a practical solution for the realization of large-area and low-cost label-free plasmonic biosensing systems, with a reduction in complexity and cost of the fabrication process of complementary plasmonic structures and metasurfaces.
Collapse
|
40
|
Bak G, Choi JH, Jang HI, Jang JS, Jeon SH, Joo KK, Ju K, Jung DE, Kim JG, Kim JH, Kim JY, Kim SB, Kim SY, Kim W, Kwon E, Lee DH, Lee HG, Lee YC, Lim IT, Moon DH, Pac MY, Park YS, Rott C, Seo H, Seo JW, Seo SH, Shin CD, Yang JY, Yoo J, Yu I. Fuel-Composition Dependent Reactor Antineutrino Yield at RENO. PHYSICAL REVIEW LETTERS 2019; 122:232501. [PMID: 31298906 DOI: 10.1103/physrevlett.122.232501] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 05/16/2019] [Indexed: 06/10/2023]
Abstract
We report a fuel-dependent reactor electron antineutrino (ν[over ¯]_{e}) yield using six 2.8 GW_{th} reactors in the Hanbit nuclear power plant complex, Yonggwang, Korea. The analysis uses 850 666 ν[over ¯]_{e} candidate events with a background fraction of 2.0% acquired through inverse beta decay (IBD) interactions in the near detector for 1807.9 live days from August 2011 to February 2018. Based on multiple fuel cycles, we observe a fuel ^{235}U dependent variation of measured IBD yields with a slope of (1.51±0.23)×10^{-43} cm^{2}/fission and measure a total average IBD yield of (5.84±0.13)×10^{-43} cm^{2}/fission. The hypothesis of no fuel-dependent IBD yield is ruled out at 6.6σ. The observed IBD yield variation over ^{235}U isotope fraction does not show significant deviation from the Huber-Mueller (HM) prediction at 1.3 σ. The measured fuel-dependent variation determines IBD yields of (6.15±0.19)×10^{-43} and (4.18±0.26)×10^{-43} cm^{2}/fission for two dominant fuel isotopes ^{235}U and ^{239}Pu, respectively. The measured IBD yield per ^{235}U fission shows the largest deficit relative to the HM prediction. Reevaluation of the ^{235}U IBD yield per fission may mostly solve the reactor antineutrino anomaly (RAA) while ^{239}Pu is not completely ruled out as a possible contributor to the anomaly. We also report a 2.9 σ correlation between the fractional change of the 5 MeV excess and the reactor fuel isotope fraction of ^{235}U.
Collapse
|
41
|
Jung Y, Hwang I, Yu J, Lee J, Choi JH, Jeong JH, Jung JY, Lee J. Fano Metamaterials on Nanopedestals for Plasmon-Enhanced Infrared Spectroscopy. Sci Rep 2019; 9:7834. [PMID: 31127173 PMCID: PMC6534610 DOI: 10.1038/s41598-019-44396-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Accepted: 05/15/2019] [Indexed: 01/29/2023] Open
Abstract
We report a sensing platform for surface-enhanced infrared absorption (SEIRA) spectroscopy, based on Fano metamaterials (FMMs) on dielectric nanopedestals. FMMs consist of two parallel gold (Au) nanorod antennas, with a small horizontal coupler attached to one of the nanorod antenna. When placed on SiO2 dielectric nanopedestals, which exhibit strong field enhancements caused by the interference between subradiant and superradiant plasmonic resonances, they provide the highly enhanced E-field intensities formed near the Au nanoantenna, which can provide more enhanced molecular detection signals. Here, the sensing characteristics of FMMs on nanopedestals structure was confirmed by comparison with FMMs on an unetched SiO2 substrate as a control sample. The control FMMs and the FMMs on nanopedestals were carefully designed to excite Fano resonance near the target 1-octadecanethiol (ODT) fingerprint vibrations. The FMMs were fabricated by using nanoimprint lithography and the nanopedestal structures were formed by isotropic dry-etching. The experimental reflection spectra containing the enhanced absorption signals of the ODT monolayer molecules was analyzed using temporal coupled-mode theory. The FMMs on nanopedestals achieved over 7% of reflection difference signal, which was 1.7 times higher signal than the one from the control FMMs. Based on the FMMs on nanopedestal structures proposed in this study, it may be widely applied to future spectroscopy and sensor applications requiring ultrasensitive detection capability.
Collapse
|
42
|
Park J, Lee M, Kim J, Choi HJ, Kwon A, Chung HS, Hong SH, Park CS, Choi JH, Chae MS. Intraoperative Management to Prevent Cardiac Collapse in a Patient With a Recurrent, Large-volume Pericardial Effusion and Paroxysmal Atrial Fibrillation During Liver Transplantation: A Case Report. Transplant Proc 2019; 51:568-574. [PMID: 30879592 DOI: 10.1016/j.transproceed.2018.12.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2018] [Accepted: 12/29/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Pericardial effusion is a common feature of end-stage liver disease. In this case report we describe the intraoperative management of recurrent pericardial effusion, without re-pericardiocentesis, to prevent circulatory collapse during a critical surgical time-point; that is, during manipulation of the major vessels and graft reperfusion. METHODS A 47-year-old woman with hepatitis B was scheduled to undergo deceased donor liver transplantation (LT). A large pericardial effusion was preoperatively identified using transthoracic echocardiography (TTE). The patient also had paroxysmal atrial fibrillation. Two days before surgery, preemptive pericardiocentesis was performed and the 1150-mL effusion was drained. Intraoperatively, recurrence of the large pericardial effusion was identified using transesophageal echocardiography (TEE). During inferior vena cava manipulation, the surgeon consulted the anesthesiologist to evaluate the hemodynamic changes in the patient. After 3 attempts, the transplant team was able to determine the most appropriate anastomosis site, defined as that with the least impact on cardiac function. To prevent the development of severe postreperfusion syndrome, 10% MgSO4 (2 g) was gradually infused 20 minutes before portal vein declamping, and immediately before graft reperfusion a 100-μg bolus of epinephrine was administered. RESULTS During graft reperfusion, there was no evidence of heart chamber collapse or flow disturbance, as seen on the TEE findings. Postoperatively, the patient recovered completely and was discharged from the hospital. Six months after surgery, there was no sign of pericardial effusion on follow-up TTE. CONCLUSION Our intraoperative strategy may prevent cardiac collapse in patients with pericardial effusion detected during LT. Intraoperative TEE plays an important role in guiding hemodynamic management.
Collapse
|
43
|
Bak G, Choi JH, Jang HI, Jang JS, Jeon SH, Joo KK, Ju K, Jung DE, Kim JG, Kim JH, Kim JY, Kim SB, Kim SY, Kim W, Kwon E, Lee DH, Lee HG, Lee YC, Lim IT, Moon DH, Pac MY, Park YS, Rott C, Seo H, Seo JW, Seo SH, Shin CD, Yang JY, Yoo J, Yu I. Measurement of Reactor Antineutrino Oscillation Amplitude and Frequency at RENO. PHYSICAL REVIEW LETTERS 2018; 121:201801. [PMID: 30500262 DOI: 10.1103/physrevlett.121.201801] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Revised: 09/13/2018] [Indexed: 06/09/2023]
Abstract
The RENO experiment reports more precisely measured values of θ_{13} and |Δm_{ee}^{2}| using ∼2200 live days of data. The amplitude and frequency of reactor electron antineutrino (ν[over ¯]_{e}) oscillation are measured by comparing the prompt signal spectra obtained from two identical near and far detectors. In the period between August 2011 and February 2018, the far (near) detector observed 103 212 (850 666) ν[over ¯]_{e} candidate events with a background fraction of 4.8% (2.0%). A clear energy and baseline dependent disappearance of reactor ν[over ¯]_{e} is observed in the deficit of the measured number of ν[over ¯]_{e}. Based on the measured far-to-near ratio of prompt spectra, we obtain sin^{2}2θ_{13}=0.0896±0.0048(stat)±0.0047(syst) and |Δm_{ee}^{2}|=[2.68±0.12(stat)±0.07(syst)]×10^{-3} eV^{2}.
Collapse
|
44
|
Kim E, Cho JW, Nguyen TK, Nguyen TTT, Yoon S, Choi JH, Park YC, Kim SK, Kim YS, Kim DW. MoS 2 monolayers on Si and SiO 2 nanocone arrays: influences of 3D dielectric material refractive index on 2D MoS 2 optical absorption. NANOSCALE 2018; 10:18920-18925. [PMID: 30288523 DOI: 10.1039/c8nr06597g] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Heterostructures enable the control of transport and recombination of charge carriers, which are either injected through electrodes, or created by light illumination. Instead of full 2D-material-heterostructures in device applications, using hybrid heterostructures consisting of 2D and 3D materials is an alternative approach to take advantage of the unique physical properties of 2D materials. In addition, 3D dielectric nanostructures exhibit useful optical properties such as broadband omnidirectional antireflection effects and strongly concentrated light near the surface. In this work, the optical properties of 2D MoS2 monolayers conformally coated on 3D Si-based nanocone (NC) arrays are investigated. Numerical calculations show that the absorption in MoS2 monolayers on SiO2 NC is significantly enhanced, compared with that for MoS2 monolayers on Si NC. The weak light confinement in low refractive index SiO2 NC leads to greater absorption in the MoS2 monolayers. The measured photoluminescence and Raman intensities of the MoS2 monolayers on SiO2 NC are much greater than those on Si NC, which supports the calculation results. This work demonstrates that 2D MoS2-3D Si nano-heterostructures are promising candidates for use in high-performance integrated optoelectronic device applications.
Collapse
|
45
|
Hwang KW, Choi JH, Jung SM, Kim YS, Lee SY, Chon MK, Lee SH, Kim JS, Park YH, Kim JH, Chun KJ, Je HG, Lee SK, Choi HO. P1520Defining the blanking period after maze procedure for atrial fibrillation. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.p1520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
46
|
Kim YS, Hwang KW, Choi HO, Jung SM, Choi JH, Lee SY, Chun MK, Lee SH, Kim JS, Je HG, Park YH, Kim JH, Lee SK, Chun KJ. P4815Incidence of incomplete surgical left atrial appendage closure. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy563.p4815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
47
|
Choe JC, Cha KS, Shin JY, Lee SH, Ahn J, Park JS, Lee HW, Oh JH, Choi JH, Lee HC, Hong TJ, Jeong MH. 1466Prognosis of biodegradable polymer drug-eluting stents versus second-generation durable polymer drug-eluting stents in acute myocardial infarction patients following percutaneous coronary intervention. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.1466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
48
|
Park I, Choi JH, Kim EK, Kim SM, Yang JH, Song YB, Hahn JY, Choi SH, Gwon HC, Lee SH, Choi YH, Oh JK. P1790Non-invasive identification of coronary collateral vessels by coronary computed tomography. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.p1790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
49
|
Tang Z, Blatnik M, Broussard LJ, Choi JH, Clayton SM, Cude-Woods C, Currie S, Fellers DE, Fries EM, Geltenbort P, Gonzalez F, Hickerson KP, Ito TM, Liu CY, MacDonald SWT, Makela M, Morris CL, O'Shaughnessy CM, Pattie RW, Plaster B, Salvat DJ, Saunders A, Wang Z, Young AR, Zeck BA. Search for the Neutron Decay n→X+γ, Where X is a Dark Matter Particle. PHYSICAL REVIEW LETTERS 2018; 121:022505. [PMID: 30085691 DOI: 10.1103/physrevlett.121.022505] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 05/01/2018] [Indexed: 06/08/2023]
Abstract
Fornal and Grinstein recently proposed that the discrepancy between two different methods of neutron lifetime measurements, the beam and bottle methods, can be explained by a previously unobserved dark matter decay mode, n→X+γ. We perform a search for this decay mode over the allowed range of energies of the monoenergetic γ ray for X to be dark matter. A Compton-suppressed high-purity germanium detector is used to identify γ rays from neutron decay in a nickel-phosphorous-coated stainless-steel bottle. A combination of Monte Carlo and radioactive source calibrations is used to determine the absolute efficiency for detecting γ rays arising from the dark matter decay mode. We exclude the possibility of a sufficiently strong branch to explain the lifetime discrepancy with 97% confidence.
Collapse
|
50
|
Han KI, Kim DH, Choi JH, Kim TK. Development of an inverse distance weighted active infrared stealth scheme using the repulsive particle swarm optimization algorithm. APPLIED OPTICS 2018; 57:3072-3077. [PMID: 29714339 DOI: 10.1364/ao.57.003072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 03/12/2018] [Indexed: 06/08/2023]
Abstract
Treatments for detection by infrared (IR) signals are higher than for other signals such as radar or sonar because an object detected by the IR sensor cannot easily recognize its detection status. Recently, research for actively reducing IR signal has been conducted to control the IR signal by adjusting the surface temperature of the object. In this paper, we propose an active IR stealth algorithm to synchronize IR signals from the object and the background around the object. The proposed method includes the repulsive particle swarm optimization statistical optimization algorithm to estimate the IR stealth surface temperature, which will result in a synchronization between the IR signals from the object and the surrounding background by setting the inverse distance weighted contrast radiant intensity (CRI) equal to zero. We tested the IR stealth performance in mid wavelength infrared (MWIR) and long wavelength infrared (LWIR) bands for a test plate located at three different positions on a forest scene to verify the proposed method. Our results show that the inverse distance weighted active IR stealth technique proposed in this study is proved to be an effective method for reducing the contrast radiant intensity between the object and background up to 32% as compared to the previous method using the CRI determined as the simple signal difference between the object and the background.
Collapse
|