26
|
Takebe T, Sekine K, Suzuki Y, Enomura M, Tanaka S, Ueno Y, Zheng YW, Taniguchi H. Self-organization of human hepatic organoid by recapitulating organogenesis in vitro. Transplant Proc 2012; 44:1018-20. [PMID: 22564614 DOI: 10.1016/j.transproceed.2012.02.007] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
BACKGROUND Careful orchestration among endodermal epithelial, endothelial, and mesenchymal cells initiate liver organogenesis prior to vascular function. Nonparenchymal endothelial or mesenchymal cells not only form passive conduits, but also establish an organogenic stimulus. Herein, we have evaluated the potential roles of primitive endothelial and mesenchymal cells toward hepatic organization in vitro. METHODS To track the cellular movements and localization, we retrovirally transduced enhanced green fluorescence protein and kusabira orange into human fetal liver cells (GFP-hFLCs) and human umbilical vein endothelial cells (KO-HUVECs), respectively. GFP-hFLCs were cocultivated with KO-HUVECs and human mesenchymal stem cells (hMSCs) under conventional two-dimensional (2D) conditions. RESULTS Even under 2D culture, fetal liver, endothelial, and mesenchymal cells self-organized into a macroscopically visible three-dimensional (3D) organoid. Time-lapse confocal imaging showed dynamic cellular organizations of GFP-hFLCs and KO-HUVECs. Endothelial cells organized into patterned clusters wrapping fetal liver cells, forming vessel-like lumens inside. Mesenchymal cells supported the generated organoid from outside. CONCLUSION Generation of whole organ architecture remains a great challenge so far. Our preliminary results showed that recapitulation of primitive cellular interactions during organogenesis elicit the intrinsic self-organizing capacity to form hepatic organoids. Future studies to define precise conditions mimicking organogenesis may ultimately lead to the generation of a functional liver for transplantation and for other applications such as drug development.
Collapse
|
27
|
Takebe T, Koike N, Sekine K, Enomura M, Chiba Y, Ueno Y, Zheng YW, Taniguchi H. Generation of functional human vascular network. Transplant Proc 2012; 44:1130-3. [PMID: 22564644 DOI: 10.1016/j.transproceed.2012.03.039] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND One of the major obstacles in regenerating thick, complex tissues such as the liver is their need for vascularization, which is essential to maintain cell viability during tissue growth and to induce structural organization. Herein, we have described a method to engineer a functional human vascular network. METHODS Enhanced green fluorescence protein-labeled human umbilical vein endothelial cells (GFP-HUVECs) were cocultivated with kusabira orange-labeled human mesenchymal stem cells (KO-hMSCs) inside a collagen/fibronectin matrix. Premature vascular network formation was visualized by fluorescence microscopy imaging. Furthermore, constructs prevascularized in vitro were implanted into a transparency window in immunodeficient mice. RESULTS Following several days of cultivation, GFP-HUVECs formed vessel-like structures that were stabilized by pericytes differentiated from KO-hMSCs. After implantation in vivo, the patency of human vascular structures was proved by rhodamine dextran infusion. These functional vascular structures remained for over 2 months. DISCUSSION Vascularization is the key challenge to organ generation. We successfully generated human vascular networks inside a matrix. Integration of parenchymal cells using our engineering technique should facilitate future efforts to reconstitute vascularized human organ systems in vitro.
Collapse
|
28
|
Takamura T, Sumiya K, Nishijima Y, Suzuki J, Sekine K. A Novel Method for Obtaining a High Performance Carbon Anode for Li-Ion Secondary Batteries. ACTA ACUST UNITED AC 2011. [DOI: 10.1557/proc-496-557] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
ABSTRACTEntire surfaces of the pitch-based well graphitized and poorly graphitized carbon fibers were covered with an evaporated metallic film of Au, Ag, Sn, or Zn, whose thickness was varied from 100 to 600 Å. Li dope and undope characteristics as the anode of Li-ion secondary battery were compared for the samples with and without evaporated film. Not only high rate charge/discharge characteristics but cycleability have been realized to be improved remarkably for the sample whose surface was covered with a thin metal film.
Collapse
|
29
|
Kitamura Y, Namura M, Shimizu T, Sekine K, Takase M, Okada T. Abstract: P458 EFFECT OF DIETARY OILS ON HIGH-FAT DIET INDUCED DYSLIPIDEMIA IN MICE. ATHEROSCLEROSIS SUPP 2009. [DOI: 10.1016/s1567-5688(09)70753-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
30
|
Nakamura H, Iwamoto M, Ogata T, Washida K, Sekine K, Takase M, Park BJ, Morikawa T, Miyazaki Y. Effects of Milk Casein-derived Peptides on Absolute Oxyhaemoglobin Concentrations in the Prefrontal Area and on Work Efficiency after Mental Stress Loading in Male Students. J Int Med Res 2008; 36:638-47. [DOI: 10.1177/147323000803600404] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
This study examined the influence of milk casein-derived peptides on cerebral activity after mental stress loading. In a crossover study, 16 male students were given a drink containing peptides (peptide group), or water (control group) before stress loading. The oxyhaemoglobin (HbO2) concentration in the prefrontal area of the brain and work efficiency were measured as indicators of cerebral activity and differences in these parameters were examined according to type A or type B personality. Type A behaviour was defined as: aggression–hostility, hard-driving—time-urgency and speed–power, whereas type B behaviour did not have these characteristics. Peptide intake resulted in a significant increase in both HbO2 concentration and work efficiency, whilst a similar increase was not seen in the control group. When divided into type A or type B personality, the changes in HbO2 concentration for the control group differed significantly in the right prefrontal area. Moreover, in type A subjects the HbO2 concentration in the right prefrontal area following intake was significantly different between the peptide and control groups.
Collapse
|
31
|
Mitamura Y, Arioka S, Sakota D, Sekine K, Azegami M. Application of a magnetic fluid seal to rotary blood pumps. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2008; 20:204145. [PMID: 21694274 DOI: 10.1088/0953-8984/20/20/204145] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.
Collapse
|
32
|
Liu H, Luo Y, Higa M, Zhang X, Saijo Y, Shiraishi Y, Sekine K, Yambe T. Biochemical evaluation of an artificial anal sphincter made from shape memory alloys. J Artif Organs 2007; 10:223-7. [PMID: 18071852 DOI: 10.1007/s10047-007-0395-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2007] [Accepted: 07/31/2007] [Indexed: 10/22/2022]
Abstract
Severe anal incontinence is a socially incapacitating disorder and a major unresolved clinical problem that has a considerable negative impact on quality of life. In this study, we developed a new artificial anal sphincter using shape memory alloys (SMAs) in order to improve the quality of life of such patients and evaluated the influence of this sphincter on blood serum chemistry in animal experiments. The artificial anal sphincter was driven by two Ti-Ni SMA actuators sandwiching the intestine and was implanted in three female goats. Blood was collected from the jugular vein on days 1 and 4; at weeks 1 and 2; and at months 1, 2, and 3, postoperatively. Biochemical parameters including total protein, albumin, total bilirubin, aspartate amino-transferase, blood urea nitrogen, creatinine, and C-reactive protein were examined. The time courses of total bilirubin and aspartate amino transferase of the three goats were within the baseline levels after 1 week of implantation and remained normal, demonstrating no liver function complications. The blood urea nitrogen and creatinine levels remained within the normal range, indicating no renal function complications. The total protein and albumin fluctuated within the normal range throughout the duration of this study. In these goats, it was also found that the level of C-reactive protein did not increase and that there was no stricture of the intestine where the artificial sphincter was attached. Our findings indicate that the artificial sphincter SMA demonstrated no adverse influence on blood serum chemistry and exhibited an effective system performance.
Collapse
|
33
|
Mitamura Y, Kido K, Yano T, Sakota D, Yambe T, Sekine K, OKamoto E. A Hydrodynamically Suspended, Magnetically Sealed Mechanically Noncontact Axial Flow Blood Pump: Design of a Hydrodynamic Bearing. Artif Organs 2007; 31:221-4. [PMID: 17343698 DOI: 10.1111/j.1525-1594.2007.00368.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
To overcome the drive shaft seal and bearing problem in rotary blood pumps, a hydrodynamic bearing, a magnetic fluid seal, and a brushless direct current (DC) motor were employed in an axial flow pump. This enabled contact-free rotation of the impeller without material wear. The axial flow pump consisted of a brushless DC motor, an impeller, and a guide vane. The motor rotor was directly connected to the impeller by a motor shaft. A hydrodynamic bearing was installed on the motor shaft. The motor and the hydrodynamic bearing were housed in a cylindrical casing and were waterproofed by a magnetic fluid seal, a mechanically noncontact seal. Impeller shaft displacement was measured using a laser sensor. Axial and radial displacements of the shaft were only a few micrometers for motor speed up to 8500 rpm. The shaft did not make contact with the bearing housing. A flow of 5 L/min was obtained at 8000 rpm at a pressure difference of 100 mm Hg. In conclusion, the axial flow blood pump consisting of a hydrodynamic bearing, a magnetic fluid seal, and a brushless DC motor provided contact-free rotation of the impeller without material wear.
Collapse
|
34
|
Shiraishi Y, Yambe T, Sekine K, Saijo Y, Wang Q, Liu H, Nitta S, Konno S, Masumoto N, Nagatoshi J, Itoh S, Park Y, Uematsu M, Umezu M, Ogawa D, Olegario P, Sato F, Yoshizawa M, Tanaka A, Tabayashi K, Sasada H, Fujimoto T, Homma D, Higa M, Hori Y. Development of an Artificial Myocardium using a Covalent Shape-memory Alloy Fiber and its Cardiovascular Diagnostic Response. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2006:406-8. [PMID: 17282200 DOI: 10.1109/iembs.2005.1616431] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The authors have been developing a newly-designed totally-implantable artificial myocardium using a covalent shape-memory alloy fibre (Biometal®, Toki Corporation), which is attached onto the ventricular wall and is also capable of supporting the natural ventricular contraction. This mechanical system consists of a contraction assistive device, which is made of Ti-Ni alloy. And the phenomenon of the martensitic transformation of the alloy was employed to achieve the physiologic motion of the device. The diameter of the alloy wire could be selected from 45 to 250μm. In this study, the basic characteristics of the fiber of 150μm was examined to design the sophisticated mechano-electric myocardium. The stress generated by the fiber was 400gf under the pulsatile driving condition (0.4W, 1Hz). Therefore it was indicated that the effective assistance might be achieved by using the Biometal shape-memory alloy fiber.
Collapse
|
35
|
Uematsu M, Shiraishi Y, Sekine K, Yambe T, Saijo Y, Park Y, Ando H, Matsumoto T, Takeda S, Iwasaki K, Umezu M. An innovative approach to evaluate a cardiac function based on surface measurement. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2005:7640-3. [PMID: 17282050 DOI: 10.1109/iembs.2005.1616281] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Major function of the heart is to pump blood flow up to all tissues or organs in the body, and it is generally recognized that cardiac function under various diseased conditions are mainly represented by a relationship between blood flow and pressure inside of the heart. In this report, an original proposal of evaluation method on cardiac function is introduced through a simultaneous measurement of various points of cardiac muscular surface. An optical three-dimensional location sensor was employed to measure a displacement change of anatomically specific points on heart surface. Then, changes in strain in each regional surface area were quantitatively obtained. This result indicated similar tendency obtained from echocardiogram. It was also indicated that there was a difference in displacements and phrases between control and arrhythmia. Moreover, strain change in regional area was coincident with a contraction of natural heart. It was found that an attempt to superimpose the data of strain change onto the video images of natural heart was extremely helpful to understand a cardiac function visually.
Collapse
|
36
|
Mitamura Y, Yambe T, Sekine K. A MAGNETICALLY SEALED, HYDRODYNAMICALLY SUSPENDED MECHANICALLY NON-CONTACT AXIAL FLOW BLOOD PUMP. ASAIO J 2006. [DOI: 10.1097/00002480-200603000-00106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
37
|
Liu H, Saijo Y, Zhang X, Shiraishi Y, Luo Y, Maruyama M, Higa M, Sekine K, Yambe T. Impact of Type A Behavior on Brachial-Ankle Pulse Wave Velocity in Japanese. TOHOKU J EXP MED 2006; 209:15-21. [PMID: 16636518 DOI: 10.1620/tjem.209.15] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Pulse wave velocity (PWV) is the velocity of a pulse wave traveling a given distance between 2 sites in the arterial system, and is a well-known indicator of arteriosclerosis. Brachial-ankle PWV (baPWV) is a parameter more simple to obtain, compared with the conventional PWV, and is an easy and effective means of evaluating arteriosclerosis. BaPWV can be obtained by only wrapping the four extremities with blood pressure cuffs, and it can be easily used to screen a large number of subjects. Type A behavior has been confirmed as an independent risk factor for the development of coronary heart disease. To examine the relationship between Type A behavior and arteriosclerosis, 307 normal Japanese subjects were classified into either a Type A group (n = 90) or a non-Type A group (n = 217) by using Maeda's Type A Scale. BaPWV was evaluated using a PWV diagnosis device. The baPWV in the Type A group was significantly higher than that obtained in the non-Type A group. The baPWV showed a positive correlation with age both in the Type A group and in the non-Type A group; however, the straight-line regression slope of baPWV versus age in the Type A group was significantly larger than that in the non-Type A group. Therefore, our results suggest that arteriosclerosis might be promoted earlier in subjects expressing the Type A behavior pattern. Type A behavior pattern is confirmed as a risk factor for arteriosclerosis, and may increase the risk of the cardiovascular disease related to arteriosclerosis.
Collapse
|
38
|
Ogawa D, Tanaka A, Abe KI, Olegario P, Kasahara K, Shiraishi Y, Sekine K, Yambe T, Nitta SI, Yoshizawa M. Evaluation of cardiac function based on ventricular pressure-volume relationships during assistance with a rotary blood pump. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2006; 2006:5378-5381. [PMID: 17946697 DOI: 10.1109/iembs.2006.260079] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Nowadays, a rotary blood pump can be used as not only for a bridge to transplantation (BTT) but also for a bridge to recovery (BTR) and a destination therapy (DT). In such cases, evaluation of the recovery level of the native heart provides useful information to improve the clinical strategy and decide adequate timing for removing of the RBP. In contrast, the indices for cardiac function have been studied. However, most of them do not consider the assistance with the RBP. In this study, we aimed at evaluating whether Emax, which is an index for cardiac function based on the pressure-volume relationships, is still valid during assistance with the RBP from an animal experiment. In the acute animal experiment with an adult goat, we measured pressure-volume (P-V) loops while cardiac function was normal, augmented or diminished. The experimental results revealed that there were typical differences in the shapes of P-V loops when the cardiac function was altered, and Emax can still be used as an index for the cardiac function even if the assistance with the RBP is ongoing.
Collapse
|
39
|
Liu H, Yambe T, Zhang X, Saijo Y, Shiraishi Y, Sekine K, Maruyama M, Kovalev YA, Milyagina IA, Milyagin VA, Nitta S. Comparison of brachial-ankle pulse wave velocity in Japanese and Russians. TOHOKU J EXP MED 2005; 207:263-70. [PMID: 16272796 DOI: 10.1620/tjem.207.263] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Pulse wave velocity (PWV) is a well-known indicator of arterial stiffness and a marker of the presence of vascular lesions. Cardiovascular mortality in Russia has become the highest in the world. The Japanese are enjoying long lives, and the mortality caused by cardiovascular diseases has thus far remained at lower levels than that in Russia. In this study, we focused on brachial-ankle pulse wave velocity (baPWV) obtained from normal human subjects in Russia as well as in Japan, and compared their respective cardiovascular risks. We evaluated baPWV in 337 Japanese and 138 Russian healthy subjects. The baPWV was recorded using a PWV diagnosis device. BaPWV was measured between 2 locations of the arterial tree. The baPWV in the Russian group was significantly higher than that obtained in the Japanese of two groups categorized by age (40-59 years and 60- years). Further, body mass index (BMI), systolic blood pressure (SBP) and diastolic blood pressure in the Russian group were significantly higher than those obtained in Japanese in three age groups (under 39 years, 40-59 years, and 60- years). Moreover, the baPWV indicated a positive correlation with age, BMI and SBP in both Japanese and Russians, although the increasing trend of the baPWV against age of the Russian group had a larger value than that of the Japanese. Therefore, we suggest that arterial stiffness might be promoted earlier in the Russian group, which might be the main cause of the increased cardiovascular risk in Russia.
Collapse
|
40
|
Yambe T, Inoue A, Sekine K, Shiraishi Y, Watanabe M, Yamaguchi T, Shibata M, Maruyama M, Konno S, Nitta S. Effect of the alternative magnetic stimulation on peripheral circulation for regenerative medicine. Biomed Pharmacother 2005; 59 Suppl 1:S174-6. [PMID: 16275489 DOI: 10.1016/s0753-3322(05)80027-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Regenerative medicine for patients with peripheral atherosclerosis attracts considerable attention around the world. However, ethical problems persist in gene therapy. This study evaluates the effect of alterative magnetic stimulation on peripheral circulation. The effect of magnetic stimulation as a medical treatment was examined using a thermograph for 11 healthy volunteers. The thermograph was used to measure the rise in skin temperature. The experimental results suggested an improvement in the peripheral circulation. The results of our study suggest the effectiveness of alternative magnetic stimulation on atherosclerosis. We intend to extend our study in order to establish a methodology for regenerative medical treatment for patients with peripheral atherosclerosis. Further, we wish to advance the current research in the field of angiogenesis.
Collapse
|
41
|
Yambe T, Meng X, Hou X, Wang Q, Sekine K, Shiraishi Y, Watanabe M, Yamaguchi T, Shibata M, Kuwayama T, Maruyama M, Konno S, Nitta S. Cardio-ankle vascular index (CAVI) for the monitoring of the atherosclerosis after heart transplantation. Biomed Pharmacother 2005; 59 Suppl 1:S177-9. [PMID: 16275490 DOI: 10.1016/s0753-3322(05)80028-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Atherosclerosis has been reported to progress rapidly after heart transplantation. A quantitative diagnosis is required for the diagnosis of atherosclerosis after heart transplantation. In this study, we compared brachial-ankle pulse wave velocity (baPWV) and cardio-ankle vascular index (CAVI) for the diagnosis. The average values of both baPWV and CAVI in the seven cases after heart transplantation were found to be signif-icantly large in comparison to the average values of the normal healthy people of the same age group. When comparisons were made before and after the heart transplantation in a particular case, CAVI was stable and baPWV changed sharply. A lot of parameters such as blood pressure, blood volume, etc. have been reported to influence baPWV. The results of this study suggested that CAVI was a stable parameter in comparison to baPWV even after heart transplantation. Thus, CAVI may be useful in the diagnosis of arteriosclerosis after heart transplantation.
Collapse
|
42
|
Yambe T, Shiraishi Y, Sekine K, Shibata MI, Yamaguchi T, Jian LH, Yoshizawa M, Tanaka A, Matsuki H, Sato F, Haga YI, Esashi M, Tabayashi K, Mitamura Y, Sasada H, Nitta SI. Development of the Pulsation Device for Rotary Blood Pumps. Artif Organs 2005; 29:912-5. [PMID: 16266306 DOI: 10.1111/j.1525-1594.2005.00159.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
A rotary blood pump (RP) is desirable as a small ventricular assist device (VAD). However, an RP is nonpulsatile. We tried to develop a device that attaches a pulse to the RP. We also tried to develop a pulse-generating equipment that was not air-pressure driven. The ball screw motor was considered a candidate. The application of a small-sized shape memory alloy was also attempted. An electrohydraulic system was adopted, and actuator power was connected to the diaphragm. The diaphragm was placed on the outer side of the ventricle. Most RPs that have been developed all over the world drain blood from the ventricle. The wave of a pulse should be generated if a pulse is added by the drawn part. The output assistance from the outer side of the ventricle was attempted in animal experiments, and the device operated effectively. This device can be used during implantable operation of RP. This may serve as an effective device in patients experiencing problems in peripheral circulation and in the function of internal organs.
Collapse
|
43
|
Yambe T, Asano E, Mauyama S, Shiraishi Y, Shibata M, Sekine K, Watanabe M, Yamaguchi T, Kuwayama T, Konno S, Nitta S. Chaos analysis of electro encephalography and control of seizure attack of epilepsy patients. Biomed Pharmacother 2005; 59 Suppl 1:S236-8. [PMID: 16275501 DOI: 10.1016/s0753-3322(05)80038-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
In order to evaluate the EEG of patients with epilepsy, chaos analysis was performed for the subdural EEG time series data. The chaos attractor was reconstructed in the phase space and the correlation dimension. KS entropy calculated from the Lyapunov exponents was evaluated. Before the seizure attack, the KS entropy showed a lower value when compared with the time series data recorded during healthy condition. The results of our study suggest that it is possible to predict the seizure attack by the chaos analysis of the EEG signal. Further, we aim at developing an automatic control system for predicting a seizure attack by the use of local cooling of the focus with Peltier elements.
Collapse
|
44
|
Watanabe M, Sekine K, Hori Y, Shiraishi Y, Maeda T, Honma D, Miyata G, Saijo Y, Yambe T. Artificial esophagus with peristaltic movement. ASAIO J 2005; 51:158-61. [PMID: 15839441 DOI: 10.1097/01.mat.0000154644.44891.f1] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
In this study, we have developed an artificial esophagus simulating peristaltic movement with the use of a nickel-titanium shape memory alloy (NiTi-SMA) actuator. Serial pairs of NiTi-SMAs were placed around a Gore-Tex vascular graft in a helical position such that they obliterated the lumen of the vessel when they contracted. In an animal experiment using a goat, the cervical esophagus was resected over a length of approximately 20 cm. The artificial esophagus was anastomosed with the remaining cervical esophagus. When a direct current of 500 mA at 5 V was applied to the NiTi-SMAs, the first pair of the NiTi-SMA contracted. The following pairs of the NiTi-SMAs contracted consecutively. The entire contraction of the artificial esophagus was similar to the esophageal peristaltic movement observed by x-ray examination in humans. The results showed the possibility that the artificial esophagus could function as an artificial esophagus having peristaltic movement.
Collapse
|
45
|
Yambe T, Sekine K, Shiraishi Y, Watanabe M, Shibata MI, Yamaguchi T, Quintian W, Duan X, Jian LH, Yoshizawa M, Tanaka A, Matsuki H, Sato F, Haga YI, Esashi M, Tabayashi K, Mitamura Y, Sasada H, Sato E, Saijo Y, Nitta SI. Addition of rhythm to non-pulsatile circulation. Biomed Pharmacother 2005; 58 Suppl 1:S145-9. [PMID: 15754854 DOI: 10.1016/s0753-3322(04)80024-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The development of a rotary blood pump (RP) is desirable as it can be used as a small ventricular assistance device (VAD). However, a RP does not generate any pulse. It may be physiologically better for the patient if the RP could generate a pulse. We have attempted to develop a device that produces a pulse in the RP. Intra-aortic balloon pumping (IABP) is effective in producing a pulse. However, the IABP cannot be implanted inside the body. Therefore, an attempt was made to develop pulse-generating equipment that was not driven by air pressure. The ball screw motor was considered as a possible candidate. In the future, we plan to apply small shape memory alloys. An electrohydraulic system was adopted, and actuator power output was connected to the diaphragm. The diaphragm was placed outside the ventricle. Most RPs developed throughout the world drain blood from the ventricle. The pulse wave should be generated if a pulse is added by the part from which blood is being drawn. In this study, animal experiments were conducted and the output assistance was tested from outside the ventricle. The device operated effectively in the animal experiment. The RP can easily be equipped with this device at the time of performing the implant operation. For a patient with problems of peripheral circulation and the internal organ function, it may prove to be an effective device.
Collapse
|
46
|
Imai T, Ito M, Takeda N, Uno A, Matsunaga T, Sekine K, Kubo T. Natural course of the remission of vertigo in patients with benign paroxysmal positional vertigo. Neurology 2005; 64:920-1. [PMID: 15753441 DOI: 10.1212/01.wnl.0000152890.00170.da] [Citation(s) in RCA: 144] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
The authors assessed the natural course of benign paroxysmal positional vertigo (BPPV) in 108 patients who were not treated with canalith repositioning procedure. The average number of days from onset to remission of positional vertigo in patients with posterior canal BPPV (P-BPPV) (39 days) was longer than in those with horizontal canal BPPV (H-BPPV) (16 days). The ratio of patients with H-BPPV to those with BPPV was 33%.
Collapse
|
47
|
Mitamura Y, Sakota D, Yano T, Sekine K, Okamoto E. A MAGNETIC FLUID SEAL INSTALLED IN A ROTARY BLOOD PUMP. ASAIO J 2005. [DOI: 10.1097/00002480-200503000-00162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
48
|
Sekine K, Ota N, Nishii M, Uetake T, Shimadzu M. Estimation of plasma and saliva levels of coenzyme Q10 and influence of oral supplementation. Biofactors 2005; 25:205-11. [PMID: 16873948 DOI: 10.1002/biof.5520250125] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Coenzyme Q10 (CoQ(10)) levels in human saliva were measured by HPLC with a highly sensitive electrochemical detector (ECD) and a special concentration column. This HPLC system showed satisfactory analytical results within the standard range of 0.78-50 ng/ml. We also found a significant correlation between CoQ(10) levels in plasma and in saliva from parotid glands, while this correlation was lacking between plasma CoQ10 and CoQ10 in whole saliva. Unlike in plasma, there are some fluctuations of saliva CoQ(10) levels throughout the day. A good correlation was obtained by collecting parotid gland saliva at times between meals. The mean saliva CoQ(10) level for 55 healthy volunteers was 17.0 ng/ml (S.D. 6.8 ng/ml); approximately one fiftieth of that in plasma. Regarding the influence of oral supplementation, CoQ(10) was analyzed in plasma and parotid gland saliva from 20 healthy volunteers supplemented daily with 100 mg of CoQ(10) for the first week and 200 mg for the second. The plasma CoQ(10) levels of all volunteers increased to different extents in accordance with the CoQ(10) daily intake and the corresponding change in saliva showed almost the same trend.
Collapse
|
49
|
Sekine K, Shima M, Nitta Y, Adachi M. Long term effects of exposure to automobile exhaust on the pulmonary function of female adults in Tokyo, Japan. Occup Environ Med 2004; 61:350-7. [PMID: 15031394 PMCID: PMC1740751 DOI: 10.1136/oem.2002.005934] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
AIMS To investigate the chronic effects of air pollution caused mainly by automobiles in healthy adult females. METHODS Respiratory symptoms were investigated in 5682 adult females who had lived in the Tokyo metropolitan area for three years or more in 1987; 733 of them were subjected to pulmonary function tests over eight years from 1987 to 1994. The subjects were divided into three groups by the level of air pollution they were exposed to during the study period. The concentrations of nitrogen dioxide and suspended particulate matter were the highest in group 1, and the lowest in group 3. RESULTS The prevalence rates of respiratory symptoms in group 1 were higher than those in groups 2 and 3, except for wheezing. Multiple logistic regression analysis showed significant differences in persistent phlegm and breathlessness. The subjects selected for the analysis of pulmonary function were 94, 210, and 102 females in groups 1, 2, and 3, respectively. The annual mean change of FEV(1) in group 1 was the largest (-0.020 l/y), followed by that in group 2 (-0.015 l/y), and that in group 3 (-0.009 l/y). Testing for trends showed a significant larger decrease of FEV(1) with the increase in the level of air pollution. CONCLUSIONS The subjects living in areas with high levels of air pollution showed higher prevalence rates of respiratory symptoms and a larger decrease of FEV(1) compared with those living in areas with low levels of air pollution. Since the traffic density is larger in areas with high air pollution, the differences among the groups may reflect the effect of air pollution attributable to particulate matter found in automobile exhaust.
Collapse
|
50
|
Sekine K, Mitamura Y, Murabayashi S, Nishimura I, Yozu R, Kim DW. Development of a magnetic fluid shaft seal for an axial-flow blood pump. Artif Organs 2004; 27:892-6. [PMID: 14616532 DOI: 10.1046/j.1525-1594.2003.00035.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A rotating impeller in a rotary blood pump requires a supporting system in blood, such as a pivot bearing or magnetic suspension. To solve potential problems such as abrasive wear and complexity of a supporting system, a magnetic fluid seal was developed for use in an axial-flow blood pump. Sealing pressures at motor speeds of up to 8,000 rpm were measured with the seal immersed in water or bovine blood. The sealing pressure was about 200 mm Hg in water and blood. The calculated theoretical sealing pressure was about 230 mm Hg. The seal remained perfect for 743 days in a static condition and for 180+ days (ongoing test) at a motor speed of 7,000 rpm. Results of measurement of cell growth activity indicated that the magnetic fluid has no negative cytological effects. The specially designed magnetic fluid shaft seal is useful for an axial-flow blood pump.
Collapse
|