51
|
Abstract
Bioinspiration is an increasingly popular design paradigm, especially as robots venture out of the laboratory and into the world. Animals are adept at coping with the variability that the world imposes. With advances in scientific tools for understanding biological structures in detail, we are increasingly able to identify design features that account for animals' robust performance. In parallel, advances in fabrication methods and materials are allowing us to engineer artificial structures with similar properties. The resulting robots become useful platforms for testing hypotheses about which principles are most important. Taking gecko-inspired climbing as an example, we show that the process of extracting principles from animals and adapting them to robots provides insights for both robotics and biology.
Collapse
|
52
|
Abstract
Since the discovery of the mechanism of adhesion in geckos, many synthetic dry adhesives have been developed with desirable gecko-like properties such as reusability, directionality, self-cleaning ability, rough surface adhesion and high adhesive stress. However, fully exploiting these adhesives in practical applications at different length scales requires efficient scaling (i.e. with little loss in adhesion as area grows). Just as natural gecko adhesives have been used as a benchmark for synthetic materials, so can gecko adhesion systems provide a baseline for scaling efficiency. In the tokay gecko (Gekko gecko), a scaling power law has been reported relating the maximum shear stress σmax to the area A: σmax ∝ A(-1/4). We present a mechanical concept which improves upon the gecko's non-uniform load-sharing and results in a nearly even load distribution over multiple patches of gecko-inspired adhesive. We created a synthetic adhesion system incorporating this concept which shows efficient scaling across four orders of magnitude of area, yielding an improved scaling power law: σmax ∝ A(-1/50). Furthermore, we found that the synthetic adhesion system does not fail catastrophically when a simulated failure is induced on a portion of the adhesive. In a practical demonstration, the synthetic adhesion system enabled a 70 kg human to climb vertical glass with 140 cm(2) of adhesive per hand.
Collapse
|
53
|
Abstract
Most robotic grasping research focuses on objects that are either not large in comparison to the gripper or have small graspable features; however, there are important applications that involve large flat or gently curved surfaces. Examples include robots that grasp the solar panels of space craft, handle large panels in manufacturing, or climb or perch on surfaces. We present a solution for grasping such surfaces consisting of groups of tiles coated with a controllable gecko-inspired adhesive. The tiles are loaded with two sets of tendons: one for distributing the forces evenly while grasping and the other for release. The gripper is passive and can attach and detach with little effort so that it does not disturb either the robot or the object to be grasped. The maximum gripping force in the normal direction can be over 1000 times greater than the required detaching force. The gripper is also fast, allowing a flying quadrotor to attach to a surface milliseconds after the tiles make contact. We present a model of the gripping mechanism and use the model to design the layout of the tiles to best support anticipated normal and tangential loads.
Collapse
|
54
|
Abstract
The manipulation of objects held in a robotic hand or gripper is accompanied by events such as making and breaking contact and slippage, between the fingertips and the grasped object and between the grasped object and external surfaces. Humans can distinguish among such events, in part, because they excite the various mechanoreceptors in the hands differently. As part of an effort to provide robots with a similar capability, we propose two features that can be extracted from dynamic tactile array data and used to discriminate between hand/object and object/world slips. Both features rely on examining how slippage affects an array of dynamic tactile sensors compared with the way it affects individual elements of the array. In comparison with approaches that require extensive training with particular combinations of objects and skin, the features work for a wide range of frequencies and grasp conditions. The performance and generalizability of the features are verified with testing on three different kinds of sensors and for a range of object textures, grasp forces and slip conditions. Both features demonstrate greater than 85% accuracy in identifying the location of slip.
Collapse
|
55
|
A Passive Parallel Master-Slave Mechanism for Magnetic Resonance Imaging-Guided Interventions. J Med Device 2015; 9:0110081-1100811. [PMID: 25729467 PMCID: PMC4245788 DOI: 10.1115/1.4028944] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2013] [Revised: 10/12/2014] [Indexed: 11/08/2022] Open
Abstract
A passive, parallel master-slave mechanism is presented for magnetic resonance imaging (MRI)-guided interventions in the pelvis. The mechanism allows a physician to stand outside the MRI scanner while manipulating a needle inside the bore and, unlike a powered robot, does not place actuators in proximity to the patient. The manipulator combines two parallel mechanisms based on the Delta robot architecture. The mechanism also includes a two-axis gimbal to allow for tool angulation, giving a total of five degrees of freedom so that the physician can insert and steer a needle using continuous natural arm and wrist movements, unlike simple needle guides. The need for access between the patient's legs and within the MRI scanner leads to an unusual asymmetric design in which the sliding prismatic joints form the vertices of an isosceles triangle. Kinematic analysis shows that the dexterity index of this design is improved over the desired workspace, as compared to an equilateral design. The analysis is extended to estimate the effect of friction and model the input:output force transmission. Prototypes, with final dimensions selected for transperineal prostate interventions, showed force transmission behavior as predicted by simulation, and easily withstood maximum forces required for tool insertion.
Collapse
|
56
|
Stress distribution and contact area measurements of a gecko toe using a high-resolution tactile sensor. BIOINSPIRATION & BIOMIMETICS 2015; 10:016013. [PMID: 25642752 DOI: 10.1088/1748-3190/10/1/016013] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The adhesive systems of geckos have been widely studied and have been a great source of bioinspiration. Load-sharing (i.e. preventing stress concentrations through equal distribution of loads) is necessary to maximize the performance of an adhesive system, but it is not known to what extent load-sharing occurs in gecko toes. In this paper, we present in vivo measurements of the stress distribution and contact area on the toes of a tokay gecko (Gekko gecko) using a custom tactile sensor with 100 μm spatial resolution. We found that the stress distributions were nonuniform, with large variations in stress between and within lamellae, suggesting that load-sharing in the tokay gecko is uneven. These results may be relevant to the understanding of gecko morphology and the design of improved synthetic adhesive systems.
Collapse
|
57
|
Abstract
An active needle is proposed for the development of magnetic resonance imaging (MRI)-guided percutaneous procedures. The needle uses a low-transition-temperature shape memory alloy (LT SMA) wire actuator to produce bending in the distal section of the needle. Actuation is achieved with internal optical heating using laser light transported via optical fibers and side coupled to the LT SMA. A prototype, with a size equivalent to a standard 16-gauge biopsy needle, exhibits significant bending, with a tip deflection of more than 14° in air and 5° in hard tissue. A single-ended optical sensor with a gold-coated tip is developed to measure the curvature independently of temperature. The experimental results in tissue phantoms show that human tissue causes fast heat dissipation from the wire actuator; however, the active needle can compensate for typical targeting errors during prostate biopsy.
Collapse
|
58
|
Autonomous real-time interventional scan plane control with a 3-D shape-sensing needle. IEEE TRANSACTIONS ON MEDICAL IMAGING 2014; 33:2128-39. [PMID: 24968093 PMCID: PMC5026644 DOI: 10.1109/tmi.2014.2332354] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
This study demonstrates real-time scan plane control dependent on three-dimensional needle bending, as measured from magnetic resonance imaging (MRI)-compatible optical strain sensors. A biopsy needle with embedded fiber Bragg grating (FBG) sensors to measure surface strains is used to estimate its full 3-D shape and control the imaging plane of an MR scanner in real-time, based on the needle's estimated profile. The needle and scanner coordinate frames are registered to each other via miniature radio-frequency (RF) tracking coils, and the scan planes autonomously track the needle as it is deflected, keeping its tip in view. A 3-D needle annotation is superimposed over MR-images presented in a 3-D environment with the scanner's frame of reference. Scan planes calculated based on the FBG sensors successfully follow the tip of the needle. Experiments using the FBG sensors and RF coils to track the needle shape and location in real-time had an average root mean square error of 4.2 mm when comparing the estimated shape to the needle profile as seen in high resolution MR images. This positional variance is less than the image artifact caused by the needle in high resolution SPGR (spoiled gradient recalled) images. Optical fiber strain sensors can estimate a needle's profile in real-time and be used for MRI scan plane control to potentially enable faster and more accurate physician response.
Collapse
|
59
|
Detection of Membrane Puncture with Haptic Feedback using a Tip-Force Sensing Needle. PROCEEDINGS OF THE ... IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS. IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS 2014; 2014:3975-3981. [PMID: 26509101 DOI: 10.1109/iros.2014.6943121] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This paper presents calibration and user test results of a 3-D tip-force sensing needle with haptic feedback. The needle is a modified MRI-compatible biopsy needle with embedded fiber Bragg grating (FBG) sensors for strain detection. After calibration, the needle is interrogated at 2 kHz, and dynamic forces are displayed remotely with a voice coil actuator. The needle is tested in a single-axis master/slave system, with the voice coil haptic display at the master, and the needle at the slave end. Tissue phantoms with embedded membranes were used to determine the ability of the tip-force sensors to provide real-time haptic feedback as compared to external sensors at the needle base during needle insertion via the master/slave system. Subjects were able to determine the position of the embedded membranes with significantly better accuracy using FBG tip feedback than with base feedback using a commercial force/torque sensor (p = 0.045) or with no added haptic feedback (p = 0.0024).
Collapse
|
60
|
Abstract
Combined jumping and gliding locomotion, or 'jumpgliding', can be an efficient way for small robots or animals to travel over cluttered terrain. This paper presents functional requirements and models for a simple jumpglider which formalize the benefits and limitations of using aerodynamic surfaces to augment jumping ability. Analysis of the model gives insight into design choices and control strategies for higher performance and to accommodate special conditions such as a slippery launching surface. The model informs the design of a robotic platform that can perform repeated jumps using a carbon fiber spring and a pivoting wing. Experiments with two different versions of the platform agree with predictions from the model and demonstrate a significantly greater range, and lower cost-of-transport, than a comparable ballistic jumper.
Collapse
|
61
|
|
62
|
Quantified self and human movement: a review on the clinical impact of wearable sensing and feedback for gait analysis and intervention. Gait Posture 2014; 40:11-9. [PMID: 24768525 DOI: 10.1016/j.gaitpost.2014.03.189] [Citation(s) in RCA: 188] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2013] [Revised: 03/10/2014] [Accepted: 03/30/2014] [Indexed: 02/02/2023]
Abstract
The proliferation of miniaturized electronics has fueled a shift toward wearable sensors and feedback devices for the mass population. Quantified self and other similar movements involving wearable systems have gained recent interest. However, it is unclear what the clinical impact of these enabling technologies is on human gait. The purpose of this review is to assess clinical applications of wearable sensing and feedback for human gait and to identify areas of future research. Four electronic databases were searched to find articles employing wearable sensing or feedback for movements of the foot, ankle, shank, thigh, hip, pelvis, and trunk during gait. We retrieved 76 articles that met the inclusion criteria and identified four common clinical applications: (1) identifying movement disorders, (2) assessing surgical outcomes, (3) improving walking stability, and (4) reducing joint loading. Characteristics of knee and trunk motion were the most frequent gait parameters for both wearable sensing and wearable feedback. Most articles performed testing on healthy subjects, and the most prevalent patient populations were osteoarthritis, vestibular loss, Parkinson's disease, and post-stroke hemiplegia. The most widely used wearable sensors were inertial measurement units (accelerometer and gyroscope packaged together) and goniometers. Haptic (touch) and auditory were the most common feedback sensations. This review highlights the current state of the literature and demonstrates substantial potential clinical benefits of wearable sensing and feedback. Future research should focus on wearable sensing and feedback in patient populations, in natural human environments outside the laboratory such as at home or work, and on continuous, long-term monitoring and intervention.
Collapse
|
63
|
Abstract
Motivated by the requirements of mobile manipulation, a compliant underactuated hand, capable of locking individual joints, has been developed. Locking is accomplished with electrostatic brakes in the joints and significantly increases the maximum pullout forces for power grasps. In addition, by locking and unlocking joints, the hand can adopt configurations and grasp sequences that would otherwise require a fully actuated solution. Other features of the hand include an integrated sensing suite that uses a common transduction technology on flexible printed circuits for tactile and proprioceptive sensing. The hand is analyzed using a three-dimensional rigid body analysis package with efficient simulation of compliant mechanisms and contacts with friction. This package allows one to evaluate design tradeoffs among link lengths, required tendon tensions, spring stiffnesses and braking requirements to grasp and hold a wide range of objects. Results of grasping and pullout tests confirm the utility of the simulations.
Collapse
|
64
|
Six-week gait retraining program reduces knee adduction moment, reduces pain, and improves function for individuals with medial compartment knee osteoarthritis. J Orthop Res 2013; 31:1020-5. [PMID: 23494804 DOI: 10.1002/jor.22340] [Citation(s) in RCA: 151] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2012] [Accepted: 02/08/2013] [Indexed: 02/04/2023]
Abstract
This study examined the influence of a 6-week gait retraining program on the knee adduction moment (KAM) and knee pain and function. Ten subjects with medial compartment knee osteoarthritis and self-reported knee pain participated in weekly gait retraining sessions over 6 weeks. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores and a 10-point visual-analog pain scale score were measured at baseline, post-training (end of 6 weeks), and 1 month after training ended. Gait retraining reduced the first peak KAM by 20% (p < 0.01) post-training as a result of a 7° decrease in foot progression angle (i.e., increased internal foot rotation), compared to baseline (p < 0.01). WOMAC pain and function scores were improved at post-training by 29% and 32%, respectively (p < 0.05) and visual-analog pain scale scores improved by two points (p < 0.05). Changes in WOMAC pain and function were approximately 75% larger than the expected placebo effect (p < 0.05). Changes in KAM, foot progression angle, WOMAC pain and function, and visual-analog pain score were retained 1 month after the end of the 6-week training period (p < 0.05). These results show that a 6-week gait retraining program can reduce the KAM and improve symptoms for individuals with medial compartment knee osteoarthritis and knee pain.
Collapse
|
65
|
MR-compatible biopsy needle with enhanced tip force sensing. JOINT EUROHAPTICS CONFERENCE AND SYMPOSIUM ON HAPTIC INTERFACES FOR VIRTUAL ENVIRONMENT AND TELEOPERATOR SYSTEMS : WORLD HAPTICS CONFERENCE. WORLD HAPTICS CONFERENCE 2013; 2013:109-114. [PMID: 26509189 DOI: 10.1109/whc.2013.6548393] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We describe an instrumented biopsy needle that provides physicians the capability to sense interaction forces directly at the tip of the needle's inner stylet. The sensors consist of optical fiber Bragg gratings (FBGs), and are unaffected by electromagnetic fields; hence the needle is suitable for MR-guided procedures. In comparison to previous instrumented needles that measure bending strains, the new design has additional sensors and a series of micro-machined holes at the tip. The holes increase strain sensitivity, especially to axial forces, without significantly reducing the stiffness or strength. A comparison of the dynamic forces measured with the new needle and those obtained using a force/torque sensor at the needle base shows that the enhanced tip sensitivity is particularly noticeable when there is significant friction along the needle sleeve.
Collapse
|
66
|
Toe-in gait reduces the first peak knee adduction moment in patients with medial compartment knee osteoarthritis. J Biomech 2013; 46:122-8. [DOI: 10.1016/j.jbiomech.2012.10.019] [Citation(s) in RCA: 105] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2012] [Revised: 10/18/2012] [Accepted: 10/21/2012] [Indexed: 10/27/2022]
|
67
|
An Optical Actuation System and Curvature Sensor for a MR-compatible Active Needle. IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION : ICRA : [PROCEEDINGS]. IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION 2012; 2012:1589-1594. [PMID: 26509099 PMCID: PMC4620050 DOI: 10.1109/icra.2012.6224964] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A side optical actuation method is presented for a slender MR-compatible active needle. The needle includes an active region with a shape memory alloy (SMA) wire actuator, where the wire generates a contraction force when optically heated by a laser delivered though optical fibers, producing needle tip bending. A prototype, with multiple side heating spots, demonstrates twice as fast an initial response compared to fiber tip heating when 0.8 W of optical power is applied. A single-ended optical sensor with a gold reflector is also presented to measure the curvature as a function of optical transmission loss. Preliminary tests with the sensor prototype demonstrate approximately linear response and a repeatable signal, independent of the bending history.
Collapse
|
68
|
Feasibility Study of an Optically Actuated MR-compatible Active Needle. PROCEEDINGS OF THE ... IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS. IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS 2011; 2011:2564-2569. [PMID: 26509100 PMCID: PMC4620048 DOI: 10.1109/iros.2011.6094945] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
An active needle is proposed for the development of MRI guided percutaneous procedures. The needle uses internal laser heating, conducted via optical fibers, of a shape memory alloy (SMA) actuator to produce bending in the distal section of the needle. Active bending of the needle as it is inserted allows it to reach small targets while overcoming the effects of interactions with surrounding tissue, which can otherwise deflect the needle away from its ideal path. The active section is designed to bend preferentially in one direction under actuation, and is also made from SMA for its combination of MR and bio-compatibility and its superelastic bending properties. A prototype, with a size equivalent to standard 16G biopsy needle, exhibits significant bending with a tip rotation of more than 10°. A numerical analysis and experiments provide information concerning the required amount of heating and guidance for design of efficient optical heating systems.
Collapse
|
69
|
Training multi-parameter gaits to reduce the knee adduction moment with data-driven models and haptic feedback. J Biomech 2011; 44:1605-9. [PMID: 21459384 DOI: 10.1016/j.jbiomech.2011.03.016] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2010] [Revised: 03/12/2011] [Accepted: 03/14/2011] [Indexed: 10/18/2022]
Abstract
The purpose of this study was to evaluate gait retraining for reducing the knee adduction moment. Our primary objective was to determine whether subject-specific altered gaits aimed at reducing the knee adduction moment by 30% or more could be identified and adopted in a single session through haptic (touch) feedback training on multiple kinematic gait parameters. Nine healthy subjects performed gait retraining, in which data-driven models specific to each subject were determined through experimental trials and were used to train novel gaits involving a combination of kinematic changes to the tibia angle, foot progression and trunk sway angles. Wearable haptic devices were used on the back, knee and foot for real-time feedback. All subjects were able to adopt altered gaits requiring simultaneous changes to multiple kinematic parameters and reduced their knee adduction moments by 29-48%. Analysis of single parameter gait training showed that moving the knee medially by increasing tibia angle, increasing trunk sway and toeing in all reduced the first peak of the knee adduction moment with tibia angle changes having the most dramatic effect. These results suggest that individualized data-driven gait retraining may be a viable option for reducing the knee adduction moment as a treatment method for early-stage knee osteoarthritis patients with sufficient sensation, endurance and motor learning capabilities.
Collapse
|
70
|
Abstract
An approach is presented whereby small, unmanned aircraft can land on walls. The approach is demonstrated with a plane that uses an ultrasonic sensor to initiate a pitch-up maneuver as it flies toward a wall. The plane contacts the wall with spines that engage asperities on the surface. A non-linear suspension absorbs the kinetic energy while keeping the spines attached. A planar dynamic model is used to evaluate pitch-up maneuvers and determine suspension parameters that satisfy constraints on the contact forces for a range of flight velocities. Simulations conducted using the model are compared with data obtained using high-speed video and a force plate embedded in a wall.
Collapse
|
71
|
Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions. IEEE/ASME TRANSACTIONS ON MECHATRONICS : A JOINT PUBLICATION OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY AND THE ASME DYNAMIC SYSTEMS AND CONTROL DIVISION 2010; 15:906-915. [PMID: 26405428 PMCID: PMC4577522 DOI: 10.1109/tmech.2010.2080360] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We describe a MRI-compatible biopsy needle instrumented with optical fiber Bragg gratings for measuring bending deflections of the needle as it is inserted into tissues. During procedures, such as diagnostic biopsies and localized treatments, it is useful to track any tool deviation from the planned trajectory to minimize positioning errors and procedural complications. The goal is to display tool deflections in real time, with greater bandwidth and accuracy than when viewing the tool in MR images. A standard 18 ga × 15 cm inner needle is prepared using a fixture, and 350-μm-deep grooves are created along its length. Optical fibers are embedded in the grooves. Two sets of sensors, located at different points along the needle, provide an estimate of the bent profile, as well as temperature compensation. Tests of the needle in a water bath showed that it produced no adverse imaging artifacts when used with the MR scanner.
Collapse
|
72
|
Landing and Perching on Vertical Surfaces with Microspines for Small Unmanned Air Vehicles. J INTELL ROBOT SYST 2009. [DOI: 10.1007/s10846-009-9377-z] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
73
|
Design and fabrication of multi-material structures for bioinspired robots. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2009; 367:1799-1813. [PMID: 19376772 DOI: 10.1098/rsta.2009.0013] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
New multi-material rapid prototyping processes are making possible the design and fabrication of bioinspired robot structures that share some of the desirable properties of animal appendages. The structures combine stiff and compliant materials and incorporate sensors and other discrete components, resulting in robots that are less demanding to control than traditionally designed robots and more robust. Current challenges include extending this approach to the structures that involve microscopic as well as macroscopic features.
Collapse
|
74
|
Force Sensing Robot Fingers using Embedded Fiber Bragg Grating Sensors and Shape Deposition Manufacturing. ACTA ACUST UNITED AC 2007. [DOI: 10.1109/robot.2007.363538] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
75
|
Whole body adhesion: hierarchical, directional and distributed control of adhesive forces for a climbing robot. ACTA ACUST UNITED AC 2007. [DOI: 10.1109/robot.2007.363159] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
76
|
Abstract
We present a new tactile display for use in dexterous telemanipulation and virtual reality. Our system renders the location of the contact centroid moving on the user’s fingertip. Constructed in a thimble-sized package and mounted on a haptic force-feedback device, it provides the user with concurrent feedback of contact location and interaction forces. We believe such a design will enable more versatile object manipulation and richer haptic interactions. To evaluate this display concept, we conducted two perceptual experiments. First, human subjects judged object curvature using both direct manipulation of physical models and virtual manipulation via the device. Results show similar levels of discrimination in real and virtual interactions, indicating the device can effectively portray contact information. Secondly, we investigated virtual interactions with rolling and anchored objects and demonstrated that users are able to distinguish the interaction type using our device. These experiments give insight into the sensitivity of human perception and suggest that even a simple display of the contact centroid location may significantly enhance telerobotic or virtual grasping tasks.
Collapse
|