26
|
Peremans K, Audenaert K, Hoybergs Y, Otte A, Goethals I, Gielen I, Blankaert P, Vervaet M, van Heeringen C, Dierckx R. The effect of citalopram hydrobromide on 5-HT2A receptors in the impulsive-aggressive dog, as measured with 123I-5-I-R91150 SPECT. Eur J Nucl Med Mol Imaging 2005; 32:708-16. [PMID: 15739093 DOI: 10.1007/s00259-005-1772-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE Involvement of the serotonergic system in impulsive aggression has been demonstrated in both human and animal studies. The purpose of the present study was to investigate the effect of citalopram hydrobromide (a selective serotonin re-uptake inhibitor) on the 5-HT(2A) receptor and brain perfusion in impulsive-aggressive dogs by means of single-photon emission computed tomography. METHODS The binding index of the radioligand (123)I-5-I-R91150 was measured before and after treatment with citalopram hydrobromide in nine impulsive-aggressive dogs. Regional perfusion was measured with (99m)Tc-ethyl cysteinate dimer (ECD). Behaviour was assessed before treatment and again after 6 weeks of treatment. RESULTS A correlation was found between decreased binding and behavioural improvement in eight out of nine dogs. The 5-HT(2A) receptor binding index was significantly reduced after citalopram hydrobromide treatment in all cortical regions but not in the subcortical area. None of the dogs displayed alterations in perfusion on the post-treatment scans. CONCLUSION This study supports previous findings regarding the involvement of the serotonergic system in impulsive aggression in dogs in general. More specifically, the effect of treatment on the 5-HT(2A) receptor binding index could be demonstrated and the decreased binding index correlated with behavioural improvement.
Collapse
|
27
|
Vandenberghe S, Staelens S, Van de Walle R, Dierckx R, Lemahieu I. Compression and reconstruction of sorted PET listmode data. Nucl Med Commun 2005; 26:819-25. [PMID: 16096586 DOI: 10.1097/01.mnm.0000175789.50294.56] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND In nuclear medicine data can be stored in histogram or listmode format. The most popular histogram format is the planar projection format. Due to the increase in detector blocks, the improved energy resolution and the trends towards time of flight, dynamic and gated imaging, it can be more appropriate to store the data in listmode format. The size of the storage in this format increases linearly with the number of properties (positions, energy, time info) while the histogram format increases exponentially. However, the datasize of listmode data also increases linearly with the number of coincidences. Due to the high number of counts in 3D PET this will lead to very large datasets. Therefore a good compression algorithm for listmode data is very important. METHODS A sorting and compression method is proposed to reduce the amount of space needed to store the listmode dataset. One event is represented by one number without any information loss compared to the original listmode file. The next step is to sort all events into an array of increasing numbers. These data are compressed by the gzip routine. One of the advantages of 3D PET listmode reconstructions is that they result in a more uniform resolution across the field of view (FOV), which is not always true for other reconstruction algorithms. This improved resolution is shown for the listmode data of a gamma camera operating in PET mode. RESULTS First the effect of positional accuracy in the listmode dataset is evaluated by comparing resolution in the reconstructions. It is shown that the highest accuracy is not necessary and a significant reduction in the size of the dataset can be obtained prior to lossless compression. A further reduction can be obtained by using the proposed sorting and compression techniques. It is shown that the storage space decreases linearly with the logarithm of the number of coincidences. The compression obtained by different acquisition matrices was compared. Finally it is shown that the 3D listmode reconstruction of sorted listmode data is faster because of improved cache behaviour. The method can be applied to any kind of listmode data. The compression factors will improve when the ratio of measured events to possible events increases.
Collapse
|
28
|
Jacobs F, Koole M, Goethals I, Van de Wiele C, Ham H, Dierckx R. Registration accuracy of 153Gd transmission images of the brain. Eur J Nucl Med Mol Imaging 2004; 31:1495-9. [PMID: 15241630 DOI: 10.1007/s00259-004-1599-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2004] [Accepted: 05/10/2004] [Indexed: 10/26/2022]
Abstract
PURPOSE The aim of the study was to determine the accuracy of non-rigid nine-parameter image registrations based on 153Gd transmission computed tomography (TCT) images as compared with those based on 99mTc-ethyl cysteinate dimer (ECD) images and to assess whether normalised mutual information (NMI) or count difference (CD) should be used. METHODS TCT and ECD data were acquired in 25 randomly selected patients. Emission images were registered to an ECD template with a CD cost function. The same registration parameters were applied to the transmission images to create a TCT template. All TCT images were registered to the TCT template and the same registration parameters were applied to the ECD images. The procedure was repeated with NMI as cost function. Accuracy of both ECD-based and TCT-based registrations was assessed by comparing the normalisation parameter values and regional activities in the spatially normalised ECD images, using a mixed-model analysis of variance (ANOVA). Scheffe post hoc tests were performed. RESULTS No significant differences were found between ECD/CD, ECD/NMI and TCT/CD, suggesting that ECD registration can be done with either CD or NMI, and that TCT registration using CD is equally as accurate as ECD registration. The accuracy of TCT registration with NMI was lower, with discrepancies occurring in the frontal inferior region and the cerebellum. The analysis of normalisation parameters indicated that z-scaling is underestimated and yz-rotation overestimated with TCT/NMI registration. CONCLUSION We conclude that ECD registrations with CD or NMI are as accurate as TCT registrations with CD and that TCT registrations with NMI should be avoided.
Collapse
|
29
|
Goethals I, Dierckx R, De Meerleer G, Gemmel F, De Neve W, Van De Wiele C. Nuclear medicine in the prediction and detection of radiation associated normal tissue damage of kidney, brain, bone marrow and salivary glands. Nucl Med Commun 2003; 24:845-52. [PMID: 12869815 DOI: 10.1097/01.mnm.0000084581.51410.46] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
30
|
Santens P, De Corte T, Vingerhoets G, Van Laere K, Dierckx R, De Reuck J. Regional cerebral blood flow and episodic memory in Parkinson's disease: a single photon emission tomography study. Eur Neurol 2003; 49:238-42. [PMID: 12736542 DOI: 10.1159/000070194] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2002] [Accepted: 01/07/2003] [Indexed: 11/19/2022]
Abstract
In this paper we examined 46 nondemented Parkinson's disease (PD) patients by means of perfusion single photon emission computed tomography (SPECT) and neuropsychological testing. The aim was to detect correlations of regional cerebral blood flow with episodic memory performance, using an operator-independent technique for the analysis of SPECT data. A significant positive correlation was found between prefrontal blood flow and episodic memory performances. However, age was the most important determinant of memory scores. Age also correlated significantly negatively with prefrontal perfusion. Our methodology also allowed detection of an inverse correlation of left medial temporal lobe perfusion with the memory score. This had not been found in previous studies and might indicate compensatory mechanisms in the brain of PD patients. It is concluded that episodic memory in nondemented PD patients is most dependent on the effects of aging and that the aging effects on cerebral perfusion in the PD brain parallel to a large extent the findings in normal controls.
Collapse
|
31
|
Peremans K, Audenaert K, Coopman F, Jacobs F, Dumont F, Slegers G, Verschooten F, van Bree H, Mertens J, Dierckx R. Regional binding index of the radiolabeled selective 5-HT2A antagonist 123I-5-I-R91150 in the normal canine brain imaged with single photon emission computed tomography. Vet Radiol Ultrasound 2003; 44:344-51. [PMID: 12816380 DOI: 10.1111/j.1740-8261.2003.tb00467.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The pattern of the specific 5-HT2A (5-hydroxytryptamine 2A receptor) antagonist 123I-5-I-R91150 was measured in 10 healthy dogs without neurologic and behavior abnormalities. Eight cortical regions (left and right fronto-, temporo-, parieto-, and occipitocortical area), one global subcortical region (including the thalamic system) were compared with a reference region lacking receptors; that is, the cerebellum. The 123I labeled radioligand was injected intravenously 100-200 minutes before acquisition. Both transmission and emission data were obtained with a triple head gamma camera equipped with high-resolution fanbeam collimators. The emission data were corrected for scatter and attenuation. To delineate different cerebral regions more accurately, the regions of interest (ROI) defined in a former study on brain perfusion measured with 99mTc-ethyl cysteinate dimer (ECD) in the same dogs were used. The co-registration of the 99mTc-ECD and the 123I-5-I-R91150, obtained from each dog, was realized with the help of corresponding transmission maps. By normalizing each regional cerebral activity to the activity observed in the cerebellum, the regional radioactivity (binding index) could be relatively quantified. Highest brain uptake was noted in the frontocortical brain areas (right: 1.85, left: 1.89), followed by the temporocortical region (right: 1.58, left: 1.56). Least uptake was noted in the more caudal and middle brain regions [occipito- (right: 1.46, left: 1.41), parietocortical (right: 1.30, left: 1.26), and striatal region (1.19)]. No gender nor age influence was noted in this series. The 123I labeled serotonin-2A receptor ligand seems to have similar cortical binding in the normal canine brain, as shown in humans and other animal species. A frontocortical to occipitocortical (rostrocaudal) binding index gradient was identified within the dog, which has not been seen in imaging studies from humans and other animal species. The significance of these results will need further investigation. This normative data can be used to compare regional brain uptake of the 123I-radioligand to dogs with behavioral disorders related to the serotonergic system, in future studies.
Collapse
|
32
|
Peremans K, Audenaert K, Jacobs F, Dumont F, De Vos F, Van De Wiele C, Vandecapelle M, Van Bree H, Verschooten F, Slegers G, Mertens J, Dierckx R. Biodistribution and displacement studies of the selective 5-HT2A receptor antagonist 123I-5-I-R91150 in the normal dog. Nucl Med Commun 2002; 23:1019-27. [PMID: 12352602 DOI: 10.1097/00006231-200210000-00013] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
There is increasing interest in mapping receptors in vivo by using functional imaging modalities such as single photon emission tomography (SPET) and positron emission tomography (PET). Since SPET is a more accessible functional imaging modality than PET and, overall, it is more economical, radioligands suitable for this technique are in greater demand. Recently, 123I-5-I-R91150, a radioligand with high selectivity and affinity for 5-HT(2A) receptors in the brain, was introduced for SPET. This study reports on the whole-body distribution and brain uptake of the selective 123I-5-I-R91150 ligand in four normal dogs. The frontal to cerebellar ratio of uptake in time was determined in three dogs. Time-activity curve of venous blood was determined in one dog. Maximal global brain uptake was found at 10-60 min post-injection. Higher brain uptake was noted in the frontal cortical areas compared to the cerebellum. The frontal-cerebellar ratio reached the highest values at 90-180 min. Reversibility and pharmacological selectivity of ligand binding was demonstrated through displacement and blocking studies with the 5-HT(2A) receptor antagonist ketanserin. This study demonstrates that the specific 5-HT(2A) iodinated ligand can be used for imaging and semi-quantification of the 5-HT(2A) receptors in the canine brain in vivo by using SPET.
Collapse
|
33
|
Audenaert K, Goethals I, Van Laere K, Lahorte P, Brans B, Versijpt J, Vervaet M, Beelaert L, Van Heeringen K, Dierckx R. SPECT neuropsychological activation procedure with the Verbal Fluency Test in attempted suicide patients. Nucl Med Commun 2002; 23:907-16. [PMID: 12195096 DOI: 10.1097/00006231-200209000-00015] [Citation(s) in RCA: 108] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Performance on the Verbal Fluency Test, as a measure of the ability of initiating processes, is reduced in depressed suicidal patients. The hampered results in this prefrontal executive task parallel the reduction in prefrontal blood perfusion and metabolism in depressed subjects. A neuropsychological activation study with the verbal fluency paradigm could evaluate a possible blunted increase in perfusion in the prefrontal cortex in depressed suicidal patients. Twenty clinically depressed patients who had recently attempted suicide and 20 healthy volunteers were included in a single photon emission computed tomography (SPECT) split-dose activation study following a verbal fluency paradigm. Statistical parametric mapping was used to determine voxelwise significant changes. Differences in regional cortical activation between the letter fluency and category fluency tasks in attempted suicide patients were found. These patients showed a blunted increase in perfusion in the prefrontal cortex. Methodological restrictions concerning group uniformity, medication bias and subjective effort of the participants are discussed. Our findings indicate a blunted increase in prefrontal blood perfusion as a possible biological reason for reduced drive and loss of initiative in attempted suicide patients.
Collapse
|
34
|
Goethals I, Dierckx R, Van Laere K, Van De Wiele C, Signore A. The role of nuclear medicine imaging in routine assessment of infectious brain pathology. Nucl Med Commun 2002; 23:819-26. [PMID: 12195082 DOI: 10.1097/00006231-200209000-00001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
35
|
Goethals I, De Winter O, De Bondt P, De Sutter J, Dierckx R, Van De Wiele C. The clinical value of nuclear medicine in the assessment of irradiation-induced and anthracycline-associated cardiac damage. Ann Oncol 2002; 13:1331-9. [PMID: 12196357 DOI: 10.1093/annonc/mdf318] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Two groups of patients, those treated for Hodgkin's disease and breast cancer, are particularly at risk of developing late myocardial damage, since radiotherapy (RT) techniques for both patient groups may include (large) parts of the heart, and adjuvant systemic therapy is frequently administered to these patients, in particular anthracycline-containing chemotherapy. Available literature on the monitoring and prediction of RT-induced and anthracycline-associated cardiac damage using nuclear medicine techniques is presented. Based on relevant studies, the risk of overall cardiac disease post-RT and overt congestive heart failure during anthracycline-containing chemotherapy is probably low. Conventional nuclear medicine imaging, i.e. myocardial perfusion scintigraphy, may be of complementary use to echocardiographical evaluation for routine follow-up after RT with modern techniques, in a subgroup of patients with known cardiovascular risk factors. Left ventricle ejection fraction (LVEF) measurements, as assessed by radionuclide angiography for the monitoring of anthracycline-associated cardiac injury, are not very sensitive and early detection will probably be enhanced by combining LVEF measurements with other cardiac function parameters. Also, it may be expected that nuclear medicine techniques using molecular radioligands will constitute an essential future step in the evaluation of subclinical cardiac injury afforded by the combined effect of RT and cardiotoxic chemotherapy.
Collapse
|
36
|
Peremans K, De Winter F, Janssens L, Dumont F, Van Bree H, Dierckx R. An infected hip prosthesis in a dog diagnosed with a 99mTc-ciprofloxacin (infecton) scan. Vet Radiol Ultrasound 2002; 43:178-82. [PMID: 11954814 DOI: 10.1111/j.1740-8261.2002.tb01666.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
This case report describes the use of the 99mTc-labeled radiopharmaceutical ciprofloxacin (Infecton) in a case of hip prosthesis loosening in a dog. Serial planar radiographs were not conclusive, and culture of the synovial fluid was negative. Antibiotic treatment did not result in improvement of the lameness. Scintigraphy was performed with 99-Tc-Infecton, a tracer claimed to be specific for infection. Antibiotic treatment was interrupted 6 weeks prior to the examination. Planar and tomographic images at 3 h and at 24 h postinjection showed increased activity along the acetabulum and the proximal femoral bone surrounding the femoral prosthesis, indicating focal infection. Bacteriology performed after removal of the implant revealed Pseudomonas aeruginosa.
Collapse
|
37
|
Peremans K, De Bondt P, Audenaert K, Van Laere K, Gielen I, Koole M, Versijpt J, Van Bree H, Verschooten F, Dierckx R. Regional brain perfusion in 10 normal dogs measured using Technetium-99m ethyl cysteinate dimer spect. Vet Radiol Ultrasound 2001; 42:562-8. [PMID: 11768526 DOI: 10.1111/j.1740-8261.2001.tb00987.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Single photon emission computed tomography (SPECT) of the brain using perfusion tracers allows estimation of regional brain perfusion. This allows in vivo examination of brain function in the setting of neuropsychologic and pathophysiologic changes. However functional imaging data on brain perfusion in dogs are limited. Hence, the aim of this study was to determine the scintigraphic regional perfusion pattern of the normal canine brain. Ten healthy shepherd type dogs were injected with 925 MBq Technetium-99m ethyl cysteinate (ECD) 20 minutes before the examination. Acquisition was performed using a triple head gamma camera equipped with fanbeam collimators. Uniform attenuation correction and triple energy window correction were applied. Computed tomographic images were obtained from the same dogs, reoriented along the orbito-meatal axis and SPECT perfusion data were coregistered to the CT-volume data. Based on morphological and suggested brain divisions, regions-of-interest (ROIs) were defined for the bilateral frontocerebral, temporocerebral, parietocerebral, occipitocerebral, cerebellar, thalamic, and striatal area. Regional count density was normalized on total counts. All dogs had the highest uptake in the thalamic/striatal area compared to a rather homogeneous cerebral uptake. No significant left/right count differences were found, but a rostro-caudal gradient (+12-13%) was present. In this group, age and gender did not influence the perfusion pattern.
Collapse
|
38
|
Dierckx R, Kley W, Verga A, Benton EV, Buschmann J. The stopping of deuterons in lithium. NUCLEAR ENGINEERING AND DESIGN/FUSION : AN INTERNATIONAL JOURNAL DEVOTED TO THE THERMAL, MECHANICAL, MATERIALS, STRUCTURAL, AND DESIGN PROBLEMS OF FUSION ENERGY 2001; 2:337-54. [PMID: 11538842 DOI: 10.1016/0167-899x(85)90022-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The interaction of 52 MeV deuterons with lithium was investigated, in view of the optimization of a lithium target for an intense neutron source based on the d-Li stripping reaction. The experimental results are compared with theoretical calculations obtained from an updated version of the Bragg code. This code describes in detail the interaction of charged particles with matter. Within the experimental uncertainties the theoretical results are well reproduced by the experiments.
Collapse
|
39
|
Van Laere K, Dumont F, Koole M, Dierckx R. Non-invasive methods for absolute cerebral blood flow measurement using 99mTc-ECD: a study in healthy volunteers. EUROPEAN JOURNAL OF NUCLEAR MEDICINE 2001; 28:862-72. [PMID: 11504083 DOI: 10.1007/s002590100559] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Radionuclide angiography with technetium-99m ethyl cysteinate dimer (ECD) allows non-invasive estimation of absolute cerebral blood flow (CBF), either by graphical Patlak-Gjedde analysis (PGA) or by spectral analysis (SA). Other methods estimate CBF by means of single-point arterial or venous sampling. The aim of this study was to evaluate radionuclide scanning and single-point venous sampling as potential clinical non- to minimally invasive methods for CBF determination in a large set of carefully screened healthy volunteers over the adult age range. Eighty-three carefully screened healthy volunteers (20-81 years, 43 males, 40 females) underwent planar radionuclide angiography with 925 MBq 99mTc-ECD. After correction for camera dead-time loss, hemispheric CBF was calculated from brain perfusion indices (BPI): BPI(G) for PGA and BPI(S) for SA. Of the volunteers, 49 also underwent venous sampling 6 min post injection, from which the lipophilic octanol extraction fraction and hemispheric brain fractionation index (BFI) were determined. All datasets were correlated and evaluated as a function of age and gender. Intrasubject variability for the BPI measurements was assessed in 11 volunteers by repeat study within 2 weeks of the first acquisition. Graphical and spectral analysis BPIs were strongly correlated (R=0.846, P<0.00001). This correlation coefficient increased to R=0.903 for the 74 cases in which graphical analysis was not hampered by temporal tracer retention in cervicobrachial venous valves. The BFI was weakly correlated to both BPI indices (BPI(G): R=0.34, P=0.02; BPI(S): R=0.31, P=0.04). The right hemisphere showed significant asymmetry for BPI(S) (AI=2.7%+/-4.3%, P<0.001), in correspondence with previous 99mTc-ECD data. BPI(G), BPI(S) and BFI were all inversely related to age, with an increased gradient after the age of 55 years, while there was no significant gender difference. The ratio of BPI(G) to BIP(S), which is a measure of the cerebral extraction fraction for 99mTc-ECD, was not dependent on age. Intersubject variability was 15.5% for both radionuclide scanning-based methods and 18.2% for venous sampling, and in all cases was independent of age. A much lower intrasubject variability was observed for BPI(S) (7.2%) than for BPI(G) (12.6%). This study provides reference values for normal perfusion indices assessed by graphical and spectral analysis. The results also indicate that spectral analysis allows the most reproducible estimate of hemispheric perfusion by means of an operator-independent and objective approach. Whereas accurate calibration of normal BPI(S) values to hemispheric CBF with established methods needs to be performed, non-invasive calculation of regional absolute CBF using 99mTc-ECD is possible by application of a linearisation algorithm.
Collapse
|
40
|
Van Laere K, Versijpt J, Audenaert K, Koole M, Goethals I, Achten E, Dierckx R. 99mTc-ECD brain perfusion SPET: variability, asymmetry and effects of age and gender in healthy adults. EUROPEAN JOURNAL OF NUCLEAR MEDICINE 2001; 28:873-87. [PMID: 11504084 DOI: 10.1007/s002590100549] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Reliable and high-resolution reference data for regional cerebral blood flow measured with single-photon emission tomography (SPET) are necessary for optimal clinical and research use. Therefore, a large dataset of normal technetium-99m labelled ethylene cysteine dimer (ECD) perfusion SPET in carefully screened healthy volunteers with an age range spanning six decades was created, with correction for non-uniform attenuation and scatter and based on an anatomically standardised analysis. Eighty-nine healthy volunteers, stratified for gender (46 females, 43 males; age 20-81 years), were included. Twelve volunteers underwent repeated 99mTc-ECD SPET after 2.5+/-2.3 weeks. An automated whole-brain volume of interest analysis with MANOVA as well as voxelwise analysis using SPM99 was conducted. Average intersubject variability was 4.8% while intrasubject reproducibility was 3.0%. An age-related decline in tracer uptake was found in the anterior cingulate gyrus, bilateral basal ganglia, left prefrontal, left lateral frontal and left superior temporal and insular cortex (all P=0.001-0.02). There was an overall increase in right/left asymmetry with age, which was most pronounced in the frontal and temporal neocortex. The most significant correlations between AI and age decade were found in the prefrontal (R=0.35, P=0.001) and superior temporal neocortex (R=0.43, P<0.001). Women had significantly higher uptake in the right parietal cortex (P<0.001), while men showed higher uptake in the cerebellum and the left anterior temporal and orbitofrontal cortex (all P<0.01). This normative dataset allows age- and gender-specific patient and group assessment of 99mTc-ECD perfusion SPET under a wide variety of clinical circumstances in relation to normal variations and highlights the importance of both age- and gender-specific normal datasets for optimal analysis sensitivity.
Collapse
|
41
|
Goethals I, Audenaert K, Van Laere K, Van De Wiele C, Dierckx R. Dopaminergic neurotransmission in psychiatry: should selection of patients only be based on DSM or ICD criteria? EUROPEAN JOURNAL OF NUCLEAR MEDICINE 2001; 28:785-7. [PMID: 11504073 DOI: 10.1007/s002590100514] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
42
|
De Sutter J, De Buyzere M, Gheeraert P, Van de Wiele C, Voet J, De Pauw M, Dierckx R, De Backer G, Taeymans Y. Fibrinogen and C-reactive protein on admission as markers of final infarct size after primary angioplasty for acute myocardial infarction. Atherosclerosis 2001; 157:189-96. [PMID: 11427220 DOI: 10.1016/s0021-9150(00)00703-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND In acute myocardial infarction (AMI) treated conservatively or with thrombolysis, marked increases of C-reactive protein (CRP) and fibrinogen have been observed. No data are however available concerning a possible relation between CRP and fibrinogen levels on admission and markers of infarct size after obtaining thrombolysis in myocardial infarction (TIMI) flow III by primary angioplasty. METHODS We studied 34 patients with a first AMI (29 men, mean age 54+/-11 years) who were treated with primary angioplasty (TIMI flow III in all patients, no concomitant treatment with glycoprotein IIb-IIIa antagonists) within 6 h of onset of pain. CRP and fibrinogen levels on admission were determined and related to the following markers of infarct size: peak creatine kinase MB (CKMB) levels, radionuclide left ventricular ejection fraction (LVEF) at discharge and thallium-201 single-photon emission computed tomography (SPECT) infarct size at 1 month. RESULTS Median CRP levels were 0.4 mg/dl (range 0.09-3 mg/dl), median fibrinogen levels 412 mg/dl (range 198-679 mg/dl), mean CKMB was 178+/-151 U/l, mean LVEF 52+/-8% and mean thallium-201 infarct size 7+/-6%. Although CRP levels were related to fibrinogen levels on admission (r=0.56, P=0.002), only fibrinogen levels were related to markers of infarct size (r=0.58, P=0.001 for CKMB, r=-0.44, P=0.01 for LVEF and r=0.64, P=0.001 for thallium-201 infarct size). No relation was found between CRP or fibrinogen levels on admission and the extent of coronary artery disease or the myocardial area at risk. In multiple regression analysis, the relation between fibrinogen and markers of infarct size was independent of CRP levels and the duration of pain on admission. CONCLUSIONS These findings indicate a relation between fibrinogen levels on admission and myocardial infarct size in patients treated with primary angioplasty for AMI. This relation seems to be independent of CRP levels and the duration of pain on admission. If confirmed in larger patient populations, fibrinogen levels on admission could have an important value for risk stratification and more aggressive reduction of infarct size in patients who are treated with primary angioplasty.
Collapse
|
43
|
Santens P, De Bleecker J, Goethals P, Strijckmans K, Lemahieu I, Slegers G, Dierckx R, De Reuck J. Differential regional cerebral uptake of (18)F-fluoro-2-deoxy-D-glucose in Alzheimer's disease and frontotemporal dementia at initial diagnosis. Eur Neurol 2001; 45:19-27. [PMID: 11150836 DOI: 10.1159/000052084] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
In this paper, the cerebral uptake of (18)F-fluoro-2-deoxy-D-glucose (FDG) was studied in a relatively small group of patients suffering from either clinically diagnosed Alzheimer's disease (AD) or frontotemporal dementia during the initial differential diagnostic workup. The image analysis was done visually and semiquantitatively using three different reference regions. Visual analysis confirmed earlier literature findings on the distribution of decreased FDG uptake and demonstrated prevalent asymmetric patterns in both groups. Only semiquantitative analysis using the sensorimotor cortex as a reference region confirmed the visual findings. Moreover, there were no differences in medial temporal lobe activities between both groups, and there was no correlation of medial temporal lobe activity with dementia severity. In the AD group, a correlation of parietal FDG uptake with MMSE scores was found.
Collapse
|
44
|
Van Laere K, Koole M, Lemahieu I, Dierckx R. Image filtering in single-photon emission computed tomography: principles and applications. Comput Med Imaging Graph 2001; 25:127-33. [PMID: 11137789 DOI: 10.1016/s0895-6111(00)00063-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Among the factors contributing to optimal image quality in single-photon emission computed tomography (SPECT), image filtering is an important, though mostly subjectively applied, image-processing parameter. We have aimed at giving an overview of current available SPECT filtering options. Current SPECT applications are discussed and practical guidelines to choose optimal filter parameters for a given situation are provided. It is shown that Hann and Butterworth filters allow accurate approximations to most filter types. The authors support the use of limited filter types in an attempt to standardise image-processing approaches, which may lead to better diagnostic compatibility and interpretation of interdepartmental results.
Collapse
|
45
|
de Winter F, Van de Wiele C, Vandenberghe S, de Bondt P, de Clercq D, D'Asseler Y, Dierckx R. Coincidence camera FDG imaging for the diagnosis of chronic orthopedic infections: a feasibility study. J Comput Assist Tomogr 2001; 25:184-9. [PMID: 11242211 DOI: 10.1097/00004728-200103000-00005] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE Results of dedicated [(18)F]fluoro-2-deoxy-d-glucose (FDG) PET imaging in patients with suspected orthopedic infections are promising. This study evaluates the feasibility of dual-head gamma-camera coincidence (DHC) imaging in this population. METHOD Twenty-four patients, referred for the confirmation or exclusion of orthopedic infection, were prospectively studied with consecutive FDG-dedicated PET and FDG DHC imaging. Images were read by two blinded readers experienced with FDG PET and compared with the final diagnosis, obtained by microbiologic proof in 11 patients and clinical follow-up of at least 9 months in 13 patients. RESULTS Nine patients had osseous infection on final diagnosis. Sensitivity, specificity, and accuracy in this limited series were (Reader 1/Reader 2), respectively, 100/100, 86/86, and 92/92% for FDG-dedicated PET and 89/89, 100/93, and 96/92% for FDG DHC imaging. CONCLUSION Despite lower image quality for FDG DHC imaging, results in this limited series were comparable with the results of FDG-dedicated PET. Further studies are needed to confirm the utility of FDG DHC imaging in suspected chronic orthopedic infections in larger patient groups.
Collapse
|
46
|
Van Laere K, Koole M, D'Asseler Y, Versijpt J, Audenaert K, Dumont F, Dierckx R. Automated stereotactic standardization of brain SPECT receptor data using single-photon transmission images. J Nucl Med 2001; 42:361-75. [PMID: 11216537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023] Open
Abstract
UNLABELLED Intra- or intersubject registration of anatomically poorly defined SPECT data, such as in neuroreceptor imaging, is important for longitudinal or group analysis. However, accurate registration is difficult with only emission CT (ECT) data. We investigated fully automated registration using transmission CT (TCT) data as an intermediary image set. METHODS The accuracy of TCT registration was compared to that of ECT registration for four types of data: gray-matter distribution (with [99mTc]ethylcysteinate dimer (ECD)), neocortical distribution (with [123I]R91150, a highly specific 5-HT2a receptor ligand), and striatal distribution of the D2-receptor ligand (with [123I]iodobenzamide (IBZM)) and the dopamine transporter ligand (with [123I]2beta-carbomethoxy-3beta-(4-fluorophenyl)tropane (CIT)). In total, 10 datasets of the various study types were used, all collected on a Toshiba GCA9300 gamma camera with super-high-resolution fanbeam collimators and 3 x 370 MBq of 153Gd transmission sources (4-min sequential TCT scanning for receptor studies and 20-min simultaneous scanning for [99mTc]ECD studies). Per dataset, 15 random misalignments of 9 rigid-body parameters (translation, rotation, and anisotropic scaling) were conducted. All coregistrations were done twice, both to the subject's original scan and to a study-specific template. This was done manually by two independent experienced observers and with three automated voxel similarity algorithms: mutual information (M.I.), count difference (C.D.), and uniformity index (U.I.). As an outcome measure, the impact of misregistration on semiquantification for the various study types was established. RESULTS TCT matching allowed registration within 3.3 mm, 2.4 degrees, and 1.2% scaling (mean squared values for all directions) with an overall accuracy decrease in the following order: C.D. > M.I. > manual > U.I. For [99mTc]ECD and [123I]IBZM, TCT registration was as accurate as ECT registration, while it was far superior for the other receptor data types, especially for abnormal studies. The automated TCT registration accuracy corresponded to average quantification errors of 2.9% ([99mTc]ECD), 4.2% ([123I]BZM), 5.7% ([123I]R91150), and 6.1% ([123I]beta-CIT). CONCLUSION Fully automated registration through intermediary TCT images is clinically feasible, fast, and accurate. In addition to nonuniform attenuation correction, TCT scanning therefore allows coregistration for group comparisons of SPECT receptor data on a standardized or pixel-by-pixel basis.
Collapse
|
47
|
Van Laere K, Koole M, Versijpt J, Dierckx R. Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteers. EUROPEAN JOURNAL OF NUCLEAR MEDICINE 2001; 28:90-8. [PMID: 11202457 DOI: 10.1007/s002590000407] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Although non-uniform attenuation correction (NUAC) can supply more accurate absolute quantification, it is not entirely clear whether NUAC provides clear-cut benefits in the routine clinical practice of brain SPET imaging. The aim of this study was to compare the effect of NUAC versus uniform attenuation correction (UAC) on volume of interest (VOI)-based semi-quantification of a large age- and gender-stratified brain perfusion normal database. Eighty-nine healthy volunteers (46 females and 43 males, aged 20-81 years) underwent standardised high-resolution single-photon emission tomography (SPET) with 925 MBq 99mTc-ethyl cysteinate dimer (ECD) on a Toshiba GCA-9300A camera with 153Gd or 99mTc transmission CT scanning. Emission images were reconstructed by filtered back-projection and scatter corrected using the triple-energy window correction method. Both non-uniform Chang attenuation correction (one iteration) and uniform Sorenson correction (attenuation coefficient 0.09 cm(-1)) were applied. Images were automatically reoriented to a stereotactic template on which 35 predefined VOIs were defined for semi-quantification (normalisation on total VOI counts). Small but significant differences between relative VOI uptake values for NUAC versus UAC in the infratentorial region were found. VOI standard deviations were significantly smaller for UAC, 4.5% (range 2.6-7.5), than for NUAC, 5.0% (2.3-9.0) (P<0.01). Higher filter roll-off values of the transmission reconstruction filter increased noise in the emission images and altered estimated cortical attenuation coefficients as well as uptake values. In conclusion, semi-quantification based upon reconstruction with UAC results in very similar 99mTc-ECD uptake values in healthy volunteers to those obtained with NUAC, although values for the infratentorial region are slightly lower. NUAC produces a slight increase in inter-subject variability. Further study is necessary in various patient populations to establish the full clinical impact of NUAC in brain perfusion SPET.
Collapse
|
48
|
Audenaert K, Brans B, Van Laere K, Lahorte P, Versijpt J, van Heeringen K, Dierckx R. Verbal fluency as a prefrontal activation probe: a validation study using 99mTc-ECD brain SPET. EUROPEAN JOURNAL OF NUCLEAR MEDICINE 2000; 27:1800-8. [PMID: 11189943 DOI: 10.1007/s002590000351] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
This study aimed to investigate the feasibility of brain single-photon emission tomography (SPET) in the letter and category fluency paradigm of the Controlled Oral Word Association (COWA) test in healthy volunteers. Two groups each comprising ten right-handed healthy volunteers were injected twice with 370 MBq technetium-99m ethyl cysteinate dimer following a split-dose paradigm (resting and activation condition). Statistical parametric mapping (SPM96) was used to determine voxelwise significant changes. The letter fluency and the category fluency activation paradigm had a differential brain activation pattern. The posterior part of the left inferior prefrontal cortex (LIPC) was activated in both paradigms, with the category fluency task having an extra activation in the anterior LIPC. In the category fluency task, but not the letter fluency task, an activation in the right inferior prefrontal cortex was found. These findings confirm to a large extent the results of previous functional magnetic resonance imaging and positron emission tomography studies in semantic and phonological activation paradigms. The choice and validity of various methodological characteristics of the experimental design leading to these results are critically discussed. It is concluded that brain SPET activation with the letter fluency and category fluency paradigm under standard neuropsychological conditions in healthy volunteers is both technically and practically feasible.
Collapse
|
49
|
van Laere K, van der Linden C, Santens P, Vandewalle V, Caemaert J, Ir PL, van den Abbeele D, Dierckx R. 99Tc(m)-ECD SPET perfusion changes by internal pallidum stimulation in Parkinson's disease. Nucl Med Commun 2000; 21:1103-12. [PMID: 11200014 DOI: 10.1097/00006231-200012000-00003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
High-frequency stimulation of the internal pallidum is an effective surgical approach for patients with advanced Parkinson's disease suffering from motor fluctuations and L-dopa induced dyskinesia. To study the acute effects of internal pallidum stimulation, changes in cerebral blood flow were measured by means of a single-day split-dose protocol using 99Tc(m)-ECD SPET. Nine patients with advanced Parkinson's disease and with a clinical picture predominated by tremor and drug-induced dyskinesia, were imaged before and immediately after electrostimulation. Brain perfusion data were mirrored to the same electrode side (five left and four right implants), co-registered and analysed statistically on a voxel-by-voxel basis (Statistical Parametric Mapping) and by an automated volume-of-interest approach. Acute stimulation of the internal pallidum induced a significantly decreased perfusion in the ipsilateral thalamus and striatum, as well as in the right parietal cortex. For the subgroup of seven patients with effective motor score improvements, a significant correlation between thalamic and striatal perfusion changes and UPDRS III motor score was present (P = 0.04). These results suggest that effective stimulation of the internal globus pallidus may produce symptom relief through decreased activity in pallido-thalamo-cortical circuits.
Collapse
|
50
|
De Sutter J, Van de Wiele C, D'Asseler Y, De Bondt P, De Backer G, Rigo P, Dierckx R. Automatic quantification of defect size using normal templates: a comparative clinical study of three commercially available algorithms. EUROPEAN JOURNAL OF NUCLEAR MEDICINE 2000; 27:1827-34. [PMID: 11189946 DOI: 10.1007/s002590000389] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Infarct size assessed by myocardial single-photon emission tomography (SPET) imaging is an important prognostic parameter after myocardial infarction (MI). We compared three commercially available automatic quantification algorithms that make use of normal templates for the evaluation of infarct extent and severity in a large population of patients with remote MI. We studied 100 consecutive patients (80 men, mean age 63 +/- 11 years, mean LVEF 47% +/- 15%) with a remote MI who underwent resting technetium-99m tetrofosmin gated SPET study for infarct extent and severity quantification. The quantification algorithms used for comparison were a short-axis algorithm (Cedars-Emory quantitative analysis software, CEqual), a vertical long-axis algorithm (VLAX) and a three-dimensional fitting algorithm (Perfit). Semiquantitative visual infarct extent and severity assessment using a 20-segment model with a 5-point score and the relation of infarct extent and severity with rest LVEF determined by quantitative gated SPET (QGS) were used as standards to compare the different algorithms. Mean infarct extent was similar for visual analysis (30% +/- 21%) and the VLAX algorithm (25% +/- 17%), but CEqual (15% +/- 11%) and Perfit (5% +/- 6%) mean infarct extents were significantly lower compared with visual analysis and the VLAX algorithm. Moreover, infarct extent determined by Perfit was significantly lower than infarct extent determined by CEqual. Correlations between automatic and visual infarct extent and severity evaluations were moderate (r = 0.47, P < 0.0001 to r = 0.62, P < 0.0001) but comparable for all three algorithms. Correlations between LVEF and visual evaluation of infarct extent (r = -0.80, P < 0.0001) and severity (r = -0.82, P < 0.0001) were good but correlations were significantly lower for all three algorithms (r = -0.48, P < 0.0001 to r = -0.65, P < 0.0001). Systematically lower correlations were found in non-anterior infarctions (n = 69) and obese patients (BMI > or = 30 kg/m2, n = 32) compared with anterior infarctions and non-obese patients for all three algorithms. In this large series of post-MI patients, results of infarct extent and severity determination by automatic quantification algorithms that make use of normal templates were not interchangeable and correlated only moderately with semiquantitative visual analysis and LVEF.
Collapse
|