Ren X, Kebbach M, Bruhn S, Yang Q, Lin H, Bader R, Tischer T, Lutter C. Barefoot walking is more stable in the gait of balance recovery in older adults. BMC Geriatr 2022; 22:904. [PMID: 36434546 PMCID: PMC9700923 DOI: 10.1186/s12877-022-03628-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2022] [Accepted: 11/17/2022] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND Perturbation-based balance training on a treadmill is an emerging method of gait stability training with a characteristic task nature that has had positive and sustained effects on balance recovery strategies and fall reduction. Little is known about the effects produced by shod and barefoot walking. We aimed to investigate which is more appropriate, shod or barefoot walking, for perturbation-based balance training in older adults. METHODS Fourteen healthy older adults (age: 68.29 ± 3.41 years; body height: 1.76 ± 0.10 m; body mass: 81.14 ± 14.52 kg) performed normal and trip-like perturbed walking trials, shod and barefoot, on a treadmill of the Gait Real-time Analysis Interactive Lab. The marker trajectories data were processed by Human Body Model software embedded in the Gait Offline Analysis Tool. The outcomes of stride length variability, stride time variability, step width variability, and swing time variability were computed and statistically analyzed by a two-way repeated-measures analysis of variance (ANOVA) based on gait pattern (normal gait versus perturbed recovery gait) and footwear condition (shod versus barefoot). RESULTS Footwear condition effect (p = 0.0310) and gait pattern by footwear condition interaction effect (p = 0.0055) were only observed in swing time variability. Gait pattern effects were detected in all four outcomes of gait variability. CONCLUSIONS Swing time variability, independent of gait speed, could be a valid indicator to differentiate between footwear conditions. The lower swing time variability in perturbed recovery gait suggests that barefoot walking may be superior to shod walking for perturbation-based balance training in older adults.
Collapse
|
27
|
Dammer RH, Zietz C, Bader R. A Comparison of Wear Patterns on Retrieved and Simulator-Tested Total Knee Replacements. J Funct Biomater 2022; 13:256. [PMID: 36412896 PMCID: PMC9680524 DOI: 10.3390/jfb13040256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/10/2022] [Accepted: 11/16/2022] [Indexed: 11/22/2022] Open
Abstract
Aseptic implant loosening is the most common reason for revision surgery after total knee replacement. This is associated with adverse biological reactions to wear debris from the articulating implant components. To predict the amount of wear debris generated in situ, standard wear testing of total knee replacement (TKR) is carried out before its clinical use. However, wear data reported on retrievals of total knee replacement (TKR) revealed significant discrepancies compared with standard wear simulator studies. Therefore, the aim of the present study was to compare the wear patterns on identical posterior-cruciate-retaining TKR designs by analyzing retrieved and experimentally tested implants. The identification and classification of wear patterns were performed using 21 retrieved ultra-high-molecular-weight-polyethylene (UHMW-PE) inserts and four sets of inserts of identical design and material tested in a knee wear simulator. These four sets had undergone different worst-case conditions and a standard test in a wear simulator according to ISO 14243-1. Macroscopic and microscopic examinations of the polyethylene inserts were performed, including the determination of seven modes of wear that correspond to specific wear patterns, the calculation of wear areas, and the classification of the damage over the whole articulating area. Retrieved and standard wear simulator-tested UHMW-PE inserts showed significant differences in wear area and patterns. The total wear areas and the damage score were significantly larger on the retrievals (52.3% versus 23.9%, 32.7 versus 22.7). Furthermore, the range of wear patterns found on the retrievals was not reproducible in the simulator-tested inserts. However, good correspondence was found with the simulator-tested polyethylene inserts under worst-case conditions (third body wear), i.e., deep wear areas could be replicated according to the in vivo situation compared with other wear test scenarios. Based on the findings presented here, standard simulator testing can be used to directly compare different TKR designs but is limited in the prediction of their in situ wear. Preclinical wear testing may be adjusted by worst-case conditions to improve the prediction of in situ performance of total knee implants in the future.
Collapse
|
28
|
Dawson JE, Sellmann T, Porath K, Bader R, van Rienen U, Appali R, Köhling R. Cell-cell interactions and fluctuations in the direction of motility promote directed migration of osteoblasts in direct current electrotaxis. Front Bioeng Biotechnol 2022; 10:995326. [PMID: 36277406 PMCID: PMC9582662 DOI: 10.3389/fbioe.2022.995326] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 09/20/2022] [Indexed: 11/13/2022] Open
Abstract
Under both physiological (development, regeneration) and pathological conditions (cancer metastasis), cells migrate while sensing environmental cues in the form of mechanical, chemical or electrical stimuli. In the case of bone tissue, osteoblast migration is essential in bone regeneration. Although it is known that osteoblasts respond to exogenous electric fields, the underlying mechanism of electrotactic collective movement of human osteoblasts is unclear. Here, we present a computational model that describes the osteoblast cell migration in a direct current electric field as the motion of a collection of active self-propelled particles and takes into account fluctuations in the direction of single-cell migration, finite-range cell-cell interactions, and the interaction of a cell with the external electric field. By comparing this model with in vitro experiments in which human primary osteoblasts are exposed to a direct current electric field of different field strengths, we show that cell-cell interactions and fluctuations in the migration direction promote anode-directed collective migration of osteoblasts.
Collapse
|
29
|
Sahm F, Freiin Grote V, Zimmermann J, Haack F, Uhrmacher AM, van Rienen U, Bader R, Detsch R, Jonitz-Heincke A. Long-term stimulation with alternating electric fields modulates the differentiation and mineralization of human pre-osteoblasts. Front Physiol 2022; 13:965181. [PMID: 36246121 PMCID: PMC9562827 DOI: 10.3389/fphys.2022.965181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 09/13/2022] [Indexed: 11/17/2022] Open
Abstract
Biophysical stimulation by electric fields can promote bone formation in bone defects of critical size. Even though, long-term effects of alternating electric fields on the differentiation of osteoblasts are not fully understood. Human pre-osteoblasts were stimulated over 31 days to gain more information about these cellular processes. An alternating electric field with 0.7 Vrms and 20 Hz at two distances was applied and viability, mineralization, gene expression, and protein release of differentiation factors were analyzed. The viability was enhanced during the first days of stimulation. A higher electric field resulted in upregulation of typical osteogenic markers like osteoprotegerin, osteopontin, and interleukin-6, but no significant changes in mineralization. Upregulation of the osteogenic markers could be detected with a lower electric field after the first days of stimulation. As a significant increase in the mineralized matrix was identified, an enhanced osteogenesis due to low alternating electric fields can be assumed.
Collapse
|
30
|
Ren X, Lutter C, Kebbach M, Bruhn S, Bader R, Tischer T. Lower extremity joint compensatory effects during the first recovery step following slipping and stumbling perturbations in young and older subjects. BMC Geriatr 2022; 22:656. [PMID: 35948887 PMCID: PMC9367084 DOI: 10.1186/s12877-022-03354-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 07/29/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND The lower extremity may play a crucial role in compensating for gait perturbations. The study aimed to explore the mechanism of perturbation compensation by investigating the gait characteristics and lower extremity joint moment effects in young (YS) and older subjects (OS) during the first recovery gait following slipping (slipping_Rec1) and stumbling (stumbling_Rec1). METHOD An automatic perturbation-triggered program was developed using D-Flow software based on the Gait Real-time Analysis Interactive Lab to induce the two aforementioned perturbations. Marker trajectories and ground reaction forces were recorded from 15 healthy YS (age: 26.53 ± 3.04 years; body height: 1.73 ± 0.07 m; body mass: 66.81 ± 11.44 kg) and 15 healthy OS (age: 68.33 ± 3.29 years; body height: 1.76 ± 0.10 m; body mass: 81.13 ± 13.99 kg). The Human Body Model was used to compute the variables of interest. One-way analysis of variance and independent samples t-test statistical analyses were performed. RESULTS In slipping_Rec1 and stumbling_Rec1, the change in gait pattern was mainly reflected in a significant increase in step width, no alterations in step length and stance/swing ratio were revealed. Based on perturbed task specificity, lower extremity joint moments increased or decreased at specific phases of the gait cycle in both YS and OS in slipping_Rec1 and stumbling_Rec1 compared to normal gait. The two perturbed gaits reflected the respective compensatory requirements for the lower extremity joints, with both sagittal and frontal joint moments producing compensatory effects. The aging effect was not reflected in the gait pattern, but rather in the hip extension moment during the initial stance of slipping_Rec1. CONCLUSIONS Slipping appears to be more demanding for gait recovery than stumbling. Gait perturbation compensatory mechanisms for OS should concentrate on ankle strategy in the frontal plane and counter-rotation strategy around the hip.
Collapse
|
31
|
Sass JO, Burmeister U, Ganz C, Mitrovic A, Lang H, Bader R, Vogel D. Fracture strength of monolithic and glass-soldered ceramic sub-components of 5-unit fixed dental prosthesis. J Prosthodont 2022; 32:e71-e80. [PMID: 35924927 DOI: 10.1111/jopr.13586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 07/27/2022] [Indexed: 11/30/2022] Open
Abstract
PURPOSE Zirconium dioxide ceramic has been successfully introduced as a framework material for fixed dental prostheses. To reduce manufacturing constraints, joining of sub-components could be a promising approach to increase the mechanical performance of long-span fixed dental prostheses. In this experimental study, the biomechanical behavior of monolithic and soldered framework specimens for fixed dental prostheses made of Y-TZP was investigated. MATERIALS AND METHODS Framework specimens (n = 80) of 5-unit fixed dental prostheses made of Y-TZP were prepared and divided into 10 equal groups. The specimens were monolithic or composed of sub-components, which were joined using a silicate-based glass solder. Thereby, three joint geometries (diagonal, vertical with an occlusal cap, and dental attachment-based) were investigated. Moreover, the groups differed based on the mechanical test (static vs. dynamic) and further processing (veneered vs. unveneered). The framework specimens were cemented on alumina-based jaw models, where the canine and second molar were acting as abutments, before a point-load was applied. In addition, μCT scans and microscopic fractography was used to evaluate the quality of soldered joints and to determine the causes of fracture. RESULTS The determined fracture loads of the different unveneered framework specimens in static testing did not vary significantly (p = 1). Adding a veneering layer significantly increased the mechanical strength for monolithic framework specimens from 1,196.29 ±203.79 N to 1,606.85 ±128.49 N (p = 0.008). In case of soldered specimens with a dental attachment-based geometry the mechanical strength increased from 1,159.42 ±85.65 N to 1,249.53 ±191.55 N (p = 1). Within the dynamic testing, no differences were observed between monolithic and soldered framework specimens. μCT scans and fractography proved that the dental attachment-based joining geometry offers the highest quality. CONCLUSION Using glass soldering technology, sub-components of 5-unit framework specimens made of Y-TZP could be joined with mechanical properties comparable to those of monolithic frameworks. This article is protected by copyright. All rights reserved.
Collapse
|
32
|
Dammer RH, Zietz C, Reinders J, Teske M, Bader R. Influence of Accelerated Aging on the Wear Behavior of Cross-Linked Polyethylene Liners—A Hip Simulator Study. J Clin Med 2022; 11:jcm11154487. [PMID: 35956104 PMCID: PMC9369584 DOI: 10.3390/jcm11154487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 07/18/2022] [Accepted: 07/27/2022] [Indexed: 02/04/2023] Open
Abstract
Sequential cross-linked and annealed ultra-high-molecular-weight polyethylene (SX-PE) is known as a low-wear articulating partner, especially for total hip endoprostheses. Aging of polymeric materials, irrespective of if induced by shelf or in vivo life, can degrade their tribological and mechanical properties. However, changes in wear behavior of aged SX-PE liners have not been not quantified so far. An accelerated aging procedure, to simulate shelf and in vivo aging, was performed on thin SX-PE liners after five million load cycles using a simulator (“worn-aged”) as well as on new SX-PE liners (“new-aged”). A subsequent hip simulator test was performed with both thin SX-PE liner sets in combination with large-diameter ceramic femoral head, representing a combination known as advantageous for treatment after revision because of dislocation. Oxidation indices were measured on the liners after each step of the procedure. SX-PE liners after accelerated aging show bedding-in phases during simulator test, which was a characteristic only known from clinical investigations. Hence, the wear rates of the “new-aged” ((1.71 ± 0.49) mg/million cycles) and of the “worn-aged” ((9.32 ± 0.09) mg/million cycles) SX-PE were increased in the first period compared to new unaged SX-PE liners. Subsequently, the wear rates decreased for “new-aged” and “worn-aged” inserts to (0.44 ± 0.48) mg/million cycles and (2.72 ± 0.05) mg/million cycles, respectively. In conclusion, the results show promising effects of accelerated aging on SX-PE liners in simulator testing and for potential long-term use in clinical applications.
Collapse
|
33
|
Ren X, Lutter C, Kebbach M, Bruhn S, Yang Q, Bader R, Tischer T. Compensatory Responses During Slip-Induced Perturbation in Patients With Knee Osteoarthritis Compared With Healthy Older Adults: An Increased Risk of Falls? Front Bioeng Biotechnol 2022; 10:893840. [PMID: 35782515 PMCID: PMC9240265 DOI: 10.3389/fbioe.2022.893840] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 05/30/2022] [Indexed: 02/03/2023] Open
Abstract
Background: Functional impairment of the knee joint affected by osteoarthritis and loss of muscle strength leads to a significant increase in the number of falls. Nevertheless, little is known about strategies for coping with gait perturbations in patients with knee osteoarthritis (KOA). Thus, this study aimed to examine the compensatory strategies of patients with KOA in response to a backward slip perturbation compared with healthy older adults. Methods: An automated perturbation program was developed by using D-Flow software based on the Gait Real-time Analysis Interactive Lab, and an induced backward slip perturbation was implemented on nine patients with severe KOA (68.89 ± 3.59 years) and 15 age-matched healthy older adults (68.33 ± 3.29 years). Step length, gait speed, range of motion, vertical ground reaction forces, lower extremity joint angles, and joint moments were computed and analyzed. Results: Compared with older adults, patients with KOA had significantly lower step length, gait speed, and vertical ground reaction forces in both normal walking and the first recovery step following backward slip perturbations. Inadequate flexion and extension of joint angles and insufficient generation of joint moments predispose patients with KOA to fall. Hip extension angle and flexion moment, knee range of motion, and vertical ground reaction forces are key monitoring variables. Conclusion: The risk of falls for patients with KOA in response to backward slip perturbations is higher. Patients with KOA should focus not only on quadriceps muscle strength related to knee range of motion but also on improving hip extensor strength and activation through specific exercises. Targeted resistance training and perturbation-based gait training could be better options.
Collapse
|
34
|
Romischke J, Scherkus A, Saemann M, Krueger S, Bader R, Kragl U, Meyer J. Swelling and Mechanical Characterization of Polyelectrolyte Hydrogels as Potential Synthetic Cartilage Substitute Materials. Gels 2022; 8:gels8050296. [PMID: 35621594 PMCID: PMC9141488 DOI: 10.3390/gels8050296] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 05/06/2022] [Accepted: 05/09/2022] [Indexed: 02/04/2023] Open
Abstract
Hydrogels have become an increasingly interesting topic in numerous fields of application. In addition to their use as immobilization matrixes in (bio)catalysis, they are widely used in the medical sector, e.g., in drug delivery systems, contact lenses, biosensors, electrodes, and tissue engineering. Cartilage tissue engineering hydrogels from natural origins, such as collagen, hyaluronic acid, and gelatin, are widely known for their good biocompatibility. However, they often lack stability, reproducibility, and mechanical strength. Synthetic hydrogels, on the other hand, can have the advantage of tunable swelling and mechanical properties, as well as good reproducibility and lower costs. In this study, we investigated the swelling and mechanical properties of synthetic polyelectrolyte hydrogels. The resulting characteristics such as swelling degree, stiffness, stress, as well as stress-relaxation and cyclic loading behavior, were compared to a commercially available biomaterial, the ChondroFiller® liquid, which is already used to treat articular cartilage lesions. Worth mentioning are the observed good reproducibility and high mechanical strength of the synthetic hydrogels. We managed to synthesize hydrogels with a wide range of compressive moduli from 2.5 ± 0.1 to 1708.7 ± 67.7 kPa, which addresses the span of human articular cartilage.
Collapse
|
35
|
Faustino D, Brinkmeier H, Logotheti S, Jonitz-Heincke A, Yilmaz H, Takan I, Peters K, Bader R, Lang H, Pavlopoulou A, Pützer BM, Spitschak A. Novel integrated workflow allows production and in-depth quality assessment of multifactorial reprogrammed skeletal muscle cells from human stem cells. Cell Mol Life Sci 2022; 79:229. [PMID: 35396689 PMCID: PMC8993739 DOI: 10.1007/s00018-022-04264-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 03/08/2022] [Accepted: 03/20/2022] [Indexed: 11/03/2022]
Abstract
Skeletal muscle tissue engineering aims at generating biological substitutes that restore, maintain or improve normal muscle function; however, the quality of cells produced by current protocols remains insufficient. Here, we developed a multifactor-based protocol that combines adenovector (AdV)-mediated MYOD expression, small molecule inhibitor and growth factor treatment, and electrical pulse stimulation (EPS) to efficiently reprogram different types of human-derived multipotent stem cells into physiologically functional skeletal muscle cells (SMCs). The protocol was complemented through a novel in silico workflow that allows for in-depth estimation and potentially optimization of the quality of generated muscle tissue, based on the transcriptomes of transdifferentiated cells. We additionally patch-clamped phenotypic SMCs to associate their bioelectrical characteristics with their transcriptome reprogramming. Overall, we set up a comprehensive and dynamic approach at the nexus of viral vector-based technology, bioinformatics, and electrophysiology that facilitates production of high-quality skeletal muscle cells and can guide iterative cycles to improve myo-differentiation protocols.
Collapse
|
36
|
Bachmeier AT, Euler E, Bader R, Böcker W, Thaller PH. Novel approach to estimate distraction forces in distraction osteogenesis and application in the human lower leg. J Mech Behav Biomed Mater 2022; 128:105133. [PMID: 35217291 DOI: 10.1016/j.jmbbm.2022.105133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 01/18/2022] [Accepted: 02/11/2022] [Indexed: 11/19/2022]
Abstract
PURPOSE In distraction osteogenesis (DO) of long bones, new bone tissue is distracted to lengthen limbs or reconstruct bone defects. However, mechanical boundary conditions in human application such as arising forces are mainly based on limited empirical data. Our aim was the numerical determination of the callus distraction force (CDF) and the total distraction force (TDF) during DO in the tibia of adults to advance the understanding of callus tissue behavior and optimize DO procedures. METHOD We implemented a mathematical model based on an animal experiment to enable the calculation of forces arising while distracting callus tissue, excluding the influence of surrounding soft tissue (muscles, skin etc.). The CDF progression for the distraction period was calculated using the implemented model and varying distraction parameters (initial gap, area, step size, time interval, length). Further, we estimated the CDF based on reported forces in humans and compared the results to our model predictions. In addition, we calculated the TDF based on our CDF predictions in combination with reported resisting forces due to soft tissue presence in human cadavers. Finally, we compared the progressions to in vivo TDF measurements for validation. RESULTS Due to relaxation, a peak and resting CDF is observable for each distraction step. Our biomechanical results show a non-linear degressive increase of the resting and peak CDF at the beginning and a steady non-linear increase thereafter. The calculated resting and peak CDF in the tibial metaphysis ranged from 0.00075 to 0.0089 N and 0.22-2.6 N at the beginning as well as 20-25 N and 70-75 N at the end of distraction. The comparison to in vivo data showed the plausibility of our predictions and resulted in a 10-33% and 10-23% share of resting CDF in the total resting force for bone transport and elongation, respectively. Further, the percentage of peak CDF in total peak force was found to be 29-58% and 27-55% for bone transport and elongation, respectively. Moreover, our TDF predictions were valid based on the comparison to in vivo forces and resulted in a degressive increase from 6 to 125 N for the peak TDF and from 5 to 76 N for the resting TDF. CONCLUSION Our approach enables the estimation of forces arising due to the distraction of callus tissue in humans and results in plausible force progressions as well as absolute force values for the callus distraction force during DO. In combination with measurements of resisting forces due to the presence of soft tissue, the total distraction force in DO may also be evaluated. We thus propose the application of this method to approximate the behavior of mechanical callus properties during DO in humans as an alternative to in vivo measurements.
Collapse
|
37
|
Vogel D, Henke P, Haenel A, Mokros J, Liebelt M, Bader R. Experimental evaluation of the primary fixation stability of uncemented ceramic hip resurfacing implants. Proc Inst Mech Eng H 2022; 236:9544119211070892. [PMID: 35166142 DOI: 10.1177/09544119211070892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2024]
Abstract
Hip resurfacing arthroplasty is associated with increased frictional moments compared to standard heads owing to their large diameter. High frictional moments may harbor the risk of the implant loosening if the frictional moments exceed the fixation stability of the hip resurfacing arthroplasty. Therefore, the aim of this experimental study was to evaluate the fixation stability of ceramic hip resurfacing implants through a turn-off test. The test specimens, made of alumina toughened zirconia (ATZ) ceramics with an inner titanium-coated surface and square base bodies for better application to the test setup, were pushed on artificial bone materials until a predefined seating depth was achieved. Thereafter, the specimens were turned off from the artificial bone material by using a lever-arm and the turn-off moments were calculated. The density of the artificial bone material utilized (15 and 25 pcf), the press-fit (0.4 and 0.8 mm) and the size of the test specimens varied. The push-on forces ranged from 0.6 ± 0.1 kN to 5.6 ± 0.5 kN depending on the press-fit and artificial bone material. The turn-off moments relied on the respective press-fit, artificial bone material and size of the specimen. They belonged between the range of 8.5 ± 0.4 Nm and 105.4 ± 0.2 Nm. Most of the previously described frictional moments are lower compared to the turn-off moments determined in this study. However, in the worst-case scenario, the turn-off moments of the hip resurfacing implants may be reduced, especially when the adjacent bone stock has a low mineral density.
Collapse
|
38
|
Saemann M, Darowski M, Hennicke NS, Bader R, Sander M, Kluess D. Experimental analysis of early periprosthetic femoral fractures with uncemented straight hip stems. Clin Biomech (Bristol, Avon) 2022; 91:105543. [PMID: 34871913 DOI: 10.1016/j.clinbiomech.2021.105543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 10/15/2021] [Accepted: 11/24/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND The periprosthetic femoral fracture is one of the most severe complications after total hip arthroplasty and is associated with an increased mortality. The underlying causes and the patient- and implant-specific risk factors of periprosthetic femoral fractures remain insufficiently understood. The aim of this study was to gain a more profound understanding of the underlying fracture mechanisms and to provide experimental datasets for validation of computational models. METHODS Six cadaveric femurs were implanted with straight hip stems (Zweymueller design) and loaded until fracture reproducing the clinically relevant load cases stumbling and sideways fall. Displacements and the strain distribution on the surface of the femurs and implants, as well as the fracture load and implant subsidence were measured. FINDINGS For the load case stumbling the mean fracture load was 6743 N and two different mechanisms leading to fracture could be identified: high subsidence with low femoral bending and small subsidence with high femoral bending. For the load case sideways fall the mean fracture load was 1757 N and both tested femurs fractured due to a rotation of the hip stem around its own axis. The detailed datasets provided by this study can be used in future computational models. INTERPRETATION We demonstrated that the underlying fracture mechanisms of periprosthetic femoral fractures can be fundamentally different in the load case stumbling. The seating and exact position of the hip stem in the femur may correlate with implant subsidence and therefore lead to different types of fracture mechanisms resulting in different patient-specific fracture risks.
Collapse
|
39
|
Hennicke NS, Saemann M, Kluess D, Bader R, Sander M. Subject specific finite element modelling of periprosthetic femoral fractures in different load cases. J Mech Behav Biomed Mater 2021; 126:105059. [PMID: 34995835 DOI: 10.1016/j.jmbbm.2021.105059] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 12/13/2021] [Accepted: 12/19/2021] [Indexed: 11/19/2022]
Abstract
Periprosthetic femoral fractures (PFF) around total hip replacements are one of the biggest challenges for orthopaedic surgeons. To understand the risk factors and formation of these fractures, the development of a reliable finite element (FE) model incorporating bone failure is essential. Due to the anisotropic and complex hierarchical structure of bone, the mechanical behaviour under large strains is difficult to predict. In this study, a state-of-the-art subject specific FE modelling technique for bone is utilised to generate and investigate PFF. A bilinear constitutive law is applied to bone tissue in subject specific FE models of five human femurs which are virtually implanted with a straight hip stem to numerically analyse PFF. The material parameters of the models are expressed as a function of bone ash density and mapped node wise to the FE mesh. In this way the subject specific, heterogeneous structure of bone is mimicked. For material mapping of the parameters, computed tomography (CT) images of the original fresh-frozen femurs are used. Periprosthetic fractures are generated by deleting elements on the basis of a critical plastic strain failure criterion. The models are analysed under physiological and clinically relevant conditions in two different load cases re-enacting stumbling and a sideways fall on the hip. The results of the analyses are quantified with experimental data from previous work. With regard to fracture pattern, stiffness and failure load the simulations of the load case stumbling delivered the most stable and accurate results. In general, mapping of material properties was found to be an appropriate way to reproduce PFF with finite element models.
Collapse
|
40
|
Bansod YD, Kebbach M, Kluess D, Bader R, van Rienen U. Computational Analysis of Bone Remodeling in the Proximal Tibia Under Electrical Stimulation Considering the Piezoelectric Properties. Front Bioeng Biotechnol 2021; 9:705199. [PMID: 34568297 PMCID: PMC8455834 DOI: 10.3389/fbioe.2021.705199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Accepted: 08/17/2021] [Indexed: 11/22/2022] Open
Abstract
The piezoelectricity of bone is known to play a crucial role in bone adaptation and remodeling. The application of an external stimulus such as mechanical strain or electric field has the potential to enhance bone formation and implant osseointegration. Therefore, in the present study, the objective is to investigate bone remodeling under electromechanical stimulation as a step towards establishing therapeutic strategies. For the first time, piezoelectric bone remodeling in the human proximal tibia under electro-mechanical loads was analyzed using the finite element method in an open-source framework. The predicted bone density distributions were qualitatively and quantitatively assessed by comparing with the computed tomography (CT) scan and the bone mineral density (BMD) calculated from the CT, respectively. The effect of model parameters such as uniform initial bone density and reference stimulus on the final density distribution was investigated. Results of the parametric study showed that for different values of initial bone density the model predicted similar but not identical final density distribution. It was also shown that higher reference stimulus value yielded lower average bone density at the final time. The present study demonstrates an increase in bone density as a result of electrical stimulation. Thus, to minimize bone loss, for example, due to physical impairment or osteoporosis, mechanical loads during daily physical activities could be partially replaced by therapeutic electrical stimulation.
Collapse
|
41
|
Waletzko-Hellwig J, Pohl C, Riese J, Schlosser M, Dau M, Engel N, Springer A, Bader R. Effect of High Hydrostatic Pressure on Human Trabecular Bone Regarding Cell Death and Matrix Integrity. Front Bioeng Biotechnol 2021; 9:730266. [PMID: 34458245 PMCID: PMC8387795 DOI: 10.3389/fbioe.2021.730266] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 08/02/2021] [Indexed: 11/13/2022] Open
Abstract
The reconstruction of critical size bone defects is still clinically challenging. Even though the transplantation of autologous bone is used as gold standard, this therapy is accompanied by donor site morbidities as well as tissue limitations. The alternatively used allografts, which are devitalized due to thermal, chemical or physical processing, often lose their matrix integrity and have diminished biomechanical properties. High Hydrostatic Pressure (HHP) may represent a gentle alternative to already existing methods since HHP treated human osteoblasts undergo cell death and HHP treated bone cylinders maintain their mechanical properties. The aim of this study was to determine the biological effects caused by HHP treatment regarding protein/matrix integrity and type of cell death in trabecular bone cylinders. Therefore, different pressure protocols (250 and 300 MPa for 10, 20 and 30 min) and end point analysis such as quantification of DNA-fragmentation, gene expression, SDS-PAGE, FESEM analysis and histological staining were performed. While both protein and matrix integrity was preserved, molecular biological methods showed an apoptotic differentiation of cell death for lower pressures and shorter applications (250 MPa for 10 and 20 min) and necrotic differentiation for higher pressures and longer applications (300 MPa for 30 min). This study serves as a basis for further investigation as it shows that HHP successfully devitalizes trabecular bone cylinders.
Collapse
|
42
|
Emmert S, Pantermehl S, Foth A, Waletzko-Hellwig J, Hellwig G, Bader R, Illner S, Grabow N, Bekeschus S, Weltmann KD, Jung O, Boeckmann L. Combining Biocompatible and Biodegradable Scaffolds and Cold Atmospheric Plasma for Chronic Wound Regeneration. Int J Mol Sci 2021; 22:9199. [PMID: 34502107 PMCID: PMC8430875 DOI: 10.3390/ijms22179199] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 08/04/2021] [Accepted: 08/24/2021] [Indexed: 12/21/2022] Open
Abstract
Skin regeneration is a quite complex process. Epidermal differentiation alone takes about 30 days and is highly regulated. Wounds, especially chronic wounds, affect 2% to 3% of the elderly population and comprise a heterogeneous group of diseases. The prevailing reasons to develop skin wounds include venous and/or arterial circulatory disorders, diabetes, or constant pressure to the skin (decubitus). The hallmarks of modern wound treatment include debridement of dead tissue, disinfection, wound dressings that keep the wound moist but still allow air exchange, and compression bandages. Despite all these efforts there is still a huge treatment resistance and wounds will not heal. This calls for new and more efficient treatment options in combination with novel biocompatible skin scaffolds. Cold atmospheric pressure plasma (CAP) is such an innovative addition to the treatment armamentarium. In one CAP application, antimicrobial effects, wound acidification, enhanced microcirculations and cell stimulation can be achieved. It is evident that CAP treatment, in combination with novel bioengineered, biocompatible and biodegradable electrospun scaffolds, has the potential of fostering wound healing by promoting remodeling and epithelialization along such temporarily applied skin replacement scaffolds.
Collapse
|
43
|
Schulze C, Knaack F, Goosmann M, Mittelmeier W, Bader R. [Continuous Passive Motion in Orthopaedic Rehabilitation of the Shoulder Girdle - A Literature Survey]. REHABILITATION 2021; 60:364-373. [PMID: 34261143 DOI: 10.1055/a-1500-8567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND Continuous passive motion (CPM) of the shoulder is predominantly used during postoperative rehabilitation of the shoulder girdle. It is often used after rotator cuff repair (RM suture). Incapacity to work and therapy of shoulder diseases cause significant costs for the healthcare system in Germany. METHODS In a literature analysis, studies and reviews of the CPM treatment in scientific databases were therefore identified and analysed with regard to the functional outcome particular after shoulder joint surgery. The quality of the studies was evaluated using the Cochrane Collaboration's Risk of Bias Tool. RESULTS After rotator cuff suturing, clinical studies have predominantly shown a faster improvement in pain level and shoulder mobility when using CPM treatment compared to other forms of treatment. In the case of frozen shoulder, only studies with the scope of CPM in conservative treatment could be identified. Here predominantly faster pain reduction could be observed. Studies addressing CPM in the therapy of Impingement of the shoulder, fracture of the humeral head or arthroplasty of the glenohumeral joint could not be identified. The health economic effects of CPM use are controversially discussed. In the available studies, equipment and other costs are assessed differently. CONCLUSION The analysed clinical studies showed overall positive effects, e. g. a faster improvement of pain level and shoulder mobility, in the postoperative therapy of the shoulder after rotator cuff repair as well as in the conservative therapy of shoulder stiffness for the CPM treatment compared to other forms of treatment. For other entities no meaningful studies are available in the literature to date. Since the health economic effects of the use of CPM have been discussed controversial so far, potential health economic benefits of the use of CPM treatment should be evaluated in future studies.
Collapse
|
44
|
Kreller T, Sahm F, Bader R, Boccaccini AR, Jonitz-Heincke A, Detsch R. Biomimetic Calcium Phosphate Coatings for Bioactivation of Titanium Implant Surfaces: Methodological Approach and In Vitro Evaluation of Biocompatibility. MATERIALS (BASEL, SWITZERLAND) 2021; 14:3516. [PMID: 34202595 PMCID: PMC8269522 DOI: 10.3390/ma14133516] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 06/14/2021] [Accepted: 06/15/2021] [Indexed: 12/13/2022]
Abstract
Ti6Al4V as a common implant material features good mechanical properties and corrosion resistance. However, untreated, it lacks bioactivity. In contrast, coatings with calcium phosphates (CaP) were shown to improve cell-material interactions in bone tissue engineering. Therefore, this work aimed to investigate how to tailor biomimetic CaP coatings on Ti6Al4V substrates using modified biomimetic calcium phosphate (BCP) coating solutions. Furthermore, the impact of substrate immersion in a 1 M alkaline CaCl2 solution (pH = 10) on subsequent CaP coating formation was examined. CaP coatings were characterized via scanning electron microscopy, x-ray diffraction, energy-dispersive x-ray spectroscopy, and laser-scanning microscope. Biocompatibility of coatings was carried out with primary human osteoblasts analyzing cell morphology, proliferation, collagen type 1, and interleukin 6 and 8 release. Results indicate a successful formation of low crystalline hydroxyapatite (HA) on top of every sample after immersion in each BCP coating solution after 14 days. Furthermore, HA coating promoted cell proliferation and reduced the concentration of interleukins compared to the uncoated surface, assuming increased biocompatibility.
Collapse
|
45
|
Jacksteit R, Stöckel T, Behrens M, Feldhege F, Bergschmidt P, Bader R, Mittelmeier W, Skripitz R, Mau-Moeller A. Low-Load Unilateral and Bilateral Resistance Training to Restore Lower Limb Function in the Early Rehabilitation After Total Knee Arthroplasty: A Randomized Active-Controlled Clinical Trial. Front Med (Lausanne) 2021; 8:628021. [PMID: 34239883 PMCID: PMC8257942 DOI: 10.3389/fmed.2021.628021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 05/18/2021] [Indexed: 01/08/2023] Open
Abstract
Background: Continuous passive motion (CPM) is frequently used during rehabilitation following total knee arthroplasty (TKA). Low-load resistance training (LLRT) using continuous active motion (CAM) devices is a promising alternative. We investigated the effectiveness of CPM compared to LLRT using the affected leg (CAMuni) and both legs (CAMbi) in the early post-operative rehabilitation. Hypotheses: (I) LLRT (CAMuni and CAMbi) is superior to CPM, (II) additional training of the unaffected leg (CAMbi) is more effective than unilateral training (CAMuni). Materials and Methods: Eighty-five TKA patients were randomly assigned to three groups, respectively: (i) unilateral CPM of the operated leg; (ii) unilateral CAM of the operated leg (CAMuni); (iii) bilateral alternating CAM (CAMbi). Patients were assessed 1 day before TKA (pre-test), 1 day before discharge (post-test), and 3 months post-operatively (follow-up). Primary outcome: active knee flexion range of motion (ROMFlex). Secondary outcomes: active knee extension ROM (ROMExt), swelling, pain, C-reactive protein, quality of life (Qol), physical activity, timed-up-and-go performance, stair-climbing performance, quadriceps muscle strength. Analyses of covariances were performed (modified intention-to-treat and per-protocol). Results: Hypothesis I: Primary outcome: CAMbi resulted in a higher ROMFlex of 9.0° (95%CI −18.03–0.04°, d = 0.76) and 6.3° (95%CI −14.31–0.99°, d = 0.61) compared to CPM at post-test and follow-up, respectively. Secondary outcomes: At post-test, C-reactive protein was lower in both CAM groups compared with CPM. Knee pain was lower in CAMuni compared to CPM. Improved ROMExt, reduced swelling, better stair-climbing and timed-up-and-go performance were observed for CAMbi compared to CPM. At follow-up, both CAM groups reported higher Qol and CAMbi showed a better timed-up-and-go performance. Hypothesis II: Primary outcome: CAMbi resulted in a higher knee ROMFlex of 6.5° (95%CI −2.16–15.21°, d = 0.56) compared to CAMuni at post-test. Secondary outcomes: At post-test, improved ROMExt, reduced swelling, and better timed-up-and-go performance were observed in CAMbi compared to CAMuni. Conclusions: Additional LLRT of the unaffected leg (CAMbi) seems to be more effective for recovery of function than training of the affected leg only (CAMuni), which may be mediated by positive transfer effects from the unaffected to the affected limb (cross education) and/or preserved neuromuscular function of the trained, unaffected leg. Trial Registration:ClinicalTrials.gov Identifier: NCT02062138.
Collapse
|
46
|
Lange HE, Bader R, Kluess D. Endurance testing and finite element simulation of a modified hip stem for integration of an energy harvesting system. Proc Inst Mech Eng H 2021; 235:985-992. [PMID: 34137316 PMCID: PMC8649416 DOI: 10.1177/09544119211021675] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Instrumented implants are a promising approach to further improve the clinical
outcome of total hip arthroplasties. For the integrated sensors or active
functions, an electrical power supply is required. Energy harvesting concepts
can provide autonomous power with unlimited lifetime and are independent from
external equipment. However, those systems occupy space within the mechanically
loaded total hip replacement and can decrease the life span due to fatigue
failure in the altered implant. We previously presented a piezoelectric energy
harvesting system for an energy-autonomous instrumented total hip stem that
notably changes the original implant geometry. The aim of this study was to
investigate the remaining structural fatigue failure strength of the metallic
femoral implant component in a worst-case scenario. Therefore, the modified hip
stem was tested under load conditions based on ISO 7206-4:2010. The required
five million cycles were completed twice by all samples (n = 3). Additionally
applied cycles with incrementally increased load levels up to 4.7 kN did not
induce implant failure. In total, 18 million cycles were endured, outperforming
the requirements of the ISO standard. Supplementary finite element analysis was
conducted to determine stress distribution within the implant. A high stress
concentration was found in the region of modification. The stress level showed
an increase compared to the previously evaluated physiological loading situation
and was close to the fatigue data from the literature. The stress concentration
factor compared to the original geometry amounted to 2.56. The assessed stress
level in accordance with the experimental fatigue testing can serve as a maximum
reference value for further implant design modifications and optimisations.
Collapse
|
47
|
Madry H, Grässel S, Nöth U, Relja B, Bernstein A, Docheva D, Kauther MD, Katthagen JC, Bader R, van Griensven M, Wirtz DC, Raschke MJ, Huber-Lang M. The future of basic science in orthopaedics and traumatology: Cassandra or Prometheus? Eur J Med Res 2021; 26:56. [PMID: 34127057 PMCID: PMC8200553 DOI: 10.1186/s40001-021-00521-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 05/20/2021] [Indexed: 12/23/2022] Open
Abstract
Orthopaedic and trauma research is a gateway to better health and mobility, reflecting the ever-increasing and complex burden of musculoskeletal diseases and injuries in Germany, Europe and worldwide. Basic science in orthopaedics and traumatology addresses the complete organism down to the molecule among an entire life of musculoskeletal mobility. Reflecting the complex and intertwined underlying mechanisms, cooperative research in this field has discovered important mechanisms on the molecular, cellular and organ levels, which subsequently led to innovative diagnostic and therapeutic strategies that reduced individual suffering as well as the burden on the society. However, research efforts are considerably threatened by economical pressures on clinicians and scientists, growing obstacles for urgently needed translational animal research, and insufficient funding. Although sophisticated science is feasible and realized in ever more individual research groups, a main goal of the multidisciplinary members of the Basic Science Section of the German Society for Orthopaedics and Trauma Surgery is to generate overarching structures and networks to answer to the growing clinical needs. The future of basic science in orthopaedics and traumatology can only be managed by an even more intensified exchange between basic scientists and clinicians while fuelling enthusiasm of talented junior scientists and clinicians. Prioritized future projects will master a broad range of opportunities from artificial intelligence, gene- and nano-technologies to large-scale, multi-centre clinical studies. Like Prometheus in the ancient Greek myth, transferring the elucidating knowledge from basic science to the real (clinical) world will reduce the individual suffering from orthopaedic diseases and trauma as well as their socio-economic impact.
Collapse
|
48
|
Bansod YD, Kebbach M, Kluess D, Bader R, van Rienen U. Finite element analysis of bone remodelling with piezoelectric effects using an open-source framework. Biomech Model Mechanobiol 2021; 20:1147-1166. [PMID: 33740158 PMCID: PMC8154825 DOI: 10.1007/s10237-021-01439-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Accepted: 02/17/2021] [Indexed: 12/16/2022]
Abstract
Bone tissue exhibits piezoelectric properties and thus is capable of transforming mechanical stress into electrical potential. Piezoelectricity has been shown to play a vital role in bone adaptation and remodelling processes. Therefore, to better understand the interplay between mechanical and electrical stimulation during these processes, strain-adaptive bone remodelling models without and with considering the piezoelectric effect were simulated using the Python-based open-source software framework. To discretise numerical attributes, the finite element method (FEM) was used for the spatial variables and an explicit Euler scheme for the temporal derivatives. The predicted bone apparent density distributions were qualitatively and quantitatively evaluated against the radiographic scan of a human proximal femur and the bone apparent density calculated using a bone mineral density (BMD) calibration phantom, respectively. Additionally, the effect of the initial bone density on the resulting predicted density distribution was investigated globally and locally. The simulation results showed that the electrically stimulated bone surface enhanced bone deposition and these are in good agreement with previous findings from the literature. Moreover, mechanical stimuli due to daily physical activities could be supported by therapeutic electrical stimulation to reduce bone loss in case of physical impairment or osteoporosis. The bone remodelling algorithm implemented using an open-source software framework facilitates easy accessibility and reproducibility of finite element analysis made.
Collapse
|
49
|
Ellenrieder M, Souffrant R, Schulze C, Kluess D, Mittelmeier W, Bader R. Primary stability of a cementless modular revision hip stem in relation with the femoral defect size: A biomechanical study. J Orthop Surg (Hong Kong) 2021; 28:2309499020948991. [PMID: 32909886 DOI: 10.1177/2309499020948991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
PURPOSE Cementless modular fluted hip stems are commonly used in revision arthroplasty. Nevertheless, there is a wide spectrum of recommendations concerning the minimum bone stock required to enable osseous ingrowth and implant-bone micromotions <100 µm. This experimental study investigated the primary stability of a tapered cementless fluted revision stem depending on different types of bone defects. METHODS Implant-bone interface movements with a bimodular stem were examined under cyclic axial and torsional loading using composite femora. In four degrees of freedom, the implant subsidence and micromotions were captured with linear variable differential transformers for the intact femora and seven different defects ranging from Paprosky type I to type IIIB. RESULTS With a 7-cm length of intact diaphysis proximal to the isthmus (Paprosky IIIA), mean implant-bone micromotions of 66 µm occurred. An implant-bone contact zone of only 5 cm (Paprosky IIIA) resulted in micromotions notably over 100 µm and significantly increased subsidence (p < 0.05). With a Paprosky IIIB defect (3 cm of intact diaphysis) rotational instability occurred in all specimens. CONCLUSIONS Aside from critically increased interfacial micromotions (>100 µm), rotational instability emerged as a mechanism of fixation failure when the implant-bone contact zone was only 5 cm or less. Hence, future studies investigating the implant fixation in the case of femoral bone defects should consider both axial and torsional loading. With regard to the clinical application, our data suggest maintaining 7 cm of diaphyseal implant-bone contact for a safe anchorage of cementless fluted hip revision stems.
Collapse
|
50
|
Pantermehl S, Emmert S, Foth A, Grabow N, Alkildani S, Bader R, Barbeck M, Jung O. 3D Printing for Soft Tissue Regeneration and Applications in Medicine. Biomedicines 2021; 9:biomedicines9040336. [PMID: 33810541 PMCID: PMC8066192 DOI: 10.3390/biomedicines9040336] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 03/16/2021] [Accepted: 03/23/2021] [Indexed: 02/07/2023] Open
Abstract
The use of additive manufacturing (AM) technologies is a relatively young research area in modern medicine. This technology offers a fast and effective way of producing implants, tissues, or entire organs individually adapted to the needs of a patient. Today, a large number of different 3D printing technologies with individual application areas are available. This review is intended to provide a general overview of these various printing technologies and their function for medical use. For this purpose, the design and functionality of the different applications are presented and their individual strengths and weaknesses are explained. Where possible, previous studies using the respective technologies in the field of tissue engineering are briefly summarized.
Collapse
|