Bladergroen MR, Reiding KR, Hipgrave Ederveen AL, Vreeker GCM, Clerc F, Holst S, Bondt A, Wuhrer M, van der Burgt YEM. Automation of High-Throughput Mass Spectrometry-Based Plasma N-Glycome Analysis with Linkage-Specific Sialic Acid Esterification. J Proteome Res 2015; 14:4080-6. [PMID: 26179816 DOI: 10.1021/acs.jproteome.5b00538] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Glycosylation is a post-translational modification of key importance with heterogeneous structural characteristics. Previously, we have developed a robust, high-throughput MALDI-TOF-MS method for the comprehensive profiling of human plasma N-glycans. In this approach, sialic acid residues are derivatized with linkage-specificity, namely the ethylation of α2,6-linked sialic acid residues with parallel lactone formation of α2,3-linked sialic acids. In the current study, this procedure was used as a starting point for the automation of all steps on a liquid-handling robot system. This resulted in a time-efficient and fully standardized procedure with throughput times of 2.5 h for a first set of 96 samples and approximately 1 h extra for each additional sample plate. The mass analysis of the thus-obtained glycans was highly reproducible in terms of relative quantification, with improved interday repeatability as compared to that of manual processing.
Collapse
|
27
|
van den Broek I, Nouta J, Razavi M, Yip R, Bladergroen MR, Romijn FPHTM, Smit NPM, Drews O, Paape R, Suckau D, Deelder AM, van der Burgt YEM, Pearson TW, Anderson NL, Cobbaert CM. Quantification of serum apolipoproteins A-I and B-100 in clinical samples using an automated SISCAPA-MALDI-TOF-MS workflow. Methods 2015; 81:74-85. [PMID: 25766926 DOI: 10.1016/j.ymeth.2015.03.001] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2014] [Revised: 03/01/2015] [Accepted: 03/02/2015] [Indexed: 01/09/2023] Open
Abstract
A fully automated workflow was developed and validated for simultaneous quantification of the cardiovascular disease risk markers apolipoproteins A-I (apoA-I) and B-100 (apoB-100) in clinical sera. By coupling of stable-isotope standards and capture by anti-peptide antibodies (SISCAPA) for enrichment of proteotypic peptides from serum digests to matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS detection, the standardized platform enabled rapid, liquid chromatography-free quantification at a relatively high throughput of 96 samples in 12h. The average imprecision in normo- and triglyceridemic serum pools was 3.8% for apoA-I and 4.2% for apoB-100 (4 replicates over 5 days). If stored properly, the MALDI target containing enriched apoA-1 and apoB-100 peptides could be re-analyzed without any effect on bias or imprecision for at least 7 days after initial analysis. Validation of the workflow revealed excellent linearity for daily calibration with external, serum-based calibrators (R(2) of 0.984 for apoA-I and 0.976 for apoB-100 as average over five days), and absence of matrix effects or interference from triglycerides, protein content, hemolysates, or bilirubins. Quantification of apoA-I in 93 normo- and hypertriglyceridemic clinical sera showed good agreement with immunoturbidimetric analysis (slope = 1.01, R(2) = 0.95, mean bias = 4.0%). Measurement of apoB-100 in the same clinical sera using both methods, however, revealed several outliers in SISCAPA-MALDI-TOF-MS measurements, possibly as a result of the lower MALDI-TOF-MS signal intensity (slope = 1.09, R(2) = 0.91, mean bias = 2.0%). The combination of analytical performance, rapid cycle time and automation potential validate the SISCAPA-MALDI-TOF-MS platform as a valuable approach for standardized and high-throughput quantification of apoA-I and apoB-100 in large sample cohorts.
Collapse
|
28
|
van den Broek I, Romijn FPHTM, Smit NPM, van der Laarse A, Drijfhout JW, van der Burgt YEM, Cobbaert CM. Quantifying protein measurands by peptide measurements: where do errors arise? J Proteome Res 2015; 14:928-42. [PMID: 25494833 DOI: 10.1021/pr5011179] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Clinically actionable quantification of protein biomarkers by mass spectrometry (MS) requires analytical performance in concordance with quality specifications for diagnostic tests. Laboratory-developed tests should, therefore, be validated in accordance with EN ISO 15189:2012 guidelines for medical laboratories to demonstrate competence and traceability along the entire workflow, including the selected standardization strategy and the phases before, during, and after proteolysis. In this study, bias and imprecision of a previously developed MS method for quantification of serum apolipoproteins A-I (Apo A-I) and B (Apo B) were thoroughly validated according to Clinical and Laboratory Standards Institute (CLSI) guidelines EP15-A2 and EP09-A3, using 100 patient sera and either stable-isotope labeled (SIL) peptides or SIL-Apo A-I as internal standard. The systematic overview of error components assigned sample preparation before the first 4 h of proteolysis as major source (∼85%) of within-sample imprecision without external calibration. No improvement in imprecision was observed with the use of SIL-Apo A-I instead of SIL-peptides. On the contrary, when the use of SIL-Apo A-I was combined with external calibration, imprecision improved significantly (from ∼9% to ∼6%) as a result of the normalization for matrix effects on linearity. A between-sample validation of bias in 100 patient sera further supported the presence of matrix effects on digestion completeness and additionally demonstrated specimen-specific biases associated with modified peptide sequences or alterations in protease activity. In conclusion, the presented overview of bias and imprecision components contributes to a better understanding of the sources of errors in MS-based protein quantification and provides valuable recommendations to assess and control analytical quality in concordance with the requirements for clinical use.
Collapse
|
29
|
Bladergroen MR, van der Burgt YEM. Solid-phase extraction strategies to surmount body fluid sample complexity in high-throughput mass spectrometry-based proteomics. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2015; 2015:250131. [PMID: 25692071 PMCID: PMC4322654 DOI: 10.1155/2015/250131] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2014] [Revised: 01/08/2015] [Accepted: 01/08/2015] [Indexed: 05/08/2023]
Abstract
For large-scale and standardized applications in mass spectrometry- (MS-) based proteomics automation of each step is essential. Here we present high-throughput sample preparation solutions for balancing the speed of current MS-acquisitions and the time needed for analytical workup of body fluids. The discussed workflows reduce body fluid sample complexity and apply for both bottom-up proteomics experiments and top-down protein characterization approaches. Various sample preparation methods that involve solid-phase extraction (SPE) including affinity enrichment strategies have been automated. Obtained peptide and protein fractions can be mass analyzed by direct infusion into an electrospray ionization (ESI) source or by means of matrix-assisted laser desorption ionization (MALDI) without further need of time-consuming liquid chromatography (LC) separations.
Collapse
|
30
|
Velstra B, Vonk MA, Bonsing BA, Mertens BJ, Nicolardi S, Huijbers A, Vasen H, Deelder AM, Mesker WE, van der Burgt YEM, Tollenaar RAEM. Serum peptide signatures for pancreatic cancer based on mass spectrometry: a comparison to CA19-9 levels and routine imaging techniques. J Cancer Res Clin Oncol 2014; 141:531-41. [DOI: 10.1007/s00432-014-1812-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Accepted: 08/21/2014] [Indexed: 12/26/2022]
|
31
|
Smit NPM, Romijn FPHTM, van den Broek I, Drijfhout JW, Haex M, van der Laarse A, van der Burgt YEM, Cobbaert CM. Metrological traceability in mass spectrometry-based targeted protein quantitation: a proof-of-principle study for serum apolipoproteins A-I and B100. J Proteomics 2014; 109:143-61. [PMID: 24972322 DOI: 10.1016/j.jprot.2014.06.015] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2014] [Revised: 05/22/2014] [Accepted: 06/16/2014] [Indexed: 12/23/2022]
Abstract
UNLABELLED In this study, we have followed up on previous liquid chromatography (LC) multiple reaction monitoring (MRM) mass spectrometry (MS) approaches for measurement of apolipoprotein (apo) A-I and apo B100 in serum aiming for implementation of a multiplexed assay in a clinical chemistry laboratory with full metrological traceability. Signature peptides were selected and detected by dynamic MRM, and stable isotope labeled (SIL)-peptides were used as internal standards. Five apo A-I and four apo B100 peptides were measured in serum digests with linearity (R(2)>0.992) in the physiologically relevant concentration ranges. Linearity with regard to protein concentration was ascertained at five concentration levels (R(2)>0.926 and R(2)>0.965, for the apo A-I and apo B100 peptides, respectively). Three native value-assigned sera were used as external calibrators for further method verification. Imprecision values on sample preparation and LC-MS/MS acquisition were below the established minimal specifications for apo A-I and apo B100 (5.0% and 5.3%, respectively). Correlation of LC-MS/MS results with immunoturbidimetric assay results, for normo- and hypertriglyceridemic samples, showed R(2)>0.944 for apo A-I and R(2)>0.964 for apo B100. This LC-MS/MS method has potential for clinical application in normo- and dyslipidemic patients. BIOLOGICAL SIGNIFICANCE Measurement of apo A-I and apo B100 may offer an alternative to high and low density lipoprotein cholesterol (HDL-c and LDL-c) methods for cardiovascular disease risk assessment in dyslipidemic patients [1]. An LC-MS/MS method for apo A-I and apo B100 has the advantage of antibody independent and specific detection of protein signature peptides. The introduction of an LC-MS/MS method for apo A-I and apo B100 can serve as an example for many existing and newly developed (multiplex) biomarker methods in quantitative clinical chemistry proteomics (qCCP). Such LC-MS/MS methods should meet basic clinical chemistry principles with regard to test evaluation [2]. Criteria for imprecision should be pre-defined, e.g., based on biological variation. The use of commutable and traceable serum-based calibrators will improve inter-laboratory reproducibility of LC-MS/MS methods and may contribute to a more rapid transition of biomarker discovery to clinical utility with benefit for the patient treatment and improvement of general health care.
Collapse
|
32
|
Nicolardi S, Deelder AM, Palmblad M, van der Burgt YEM. Structural analysis of an intact monoclonal antibody by online electrochemical reduction of disulfide bonds and Fourier transform ion cyclotron resonance mass spectrometry. Anal Chem 2014; 86:5376-82. [PMID: 24780057 DOI: 10.1021/ac500383c] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Structural confirmation and quality control of recombinant monoclonal antibodies (mAbs) by top-down mass spectrometry is still challenging due to the size of the proteins, disulfide content, and post-translational modifications such as glycosylation. In this study we have applied electrochemistry (EC) to overcome disulfide bridge complexity in top-down analysis of mAbs. To this end, an electrochemical cell was coupled directly to an electrospray ionization (ESI) source and a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (MS) equipped with a 15 T magnet. By performing online EC-assisted reduction of interchain disulfide bonds in an intact mAb, the released light chains could be selected for tandem mass spectrometry (MS/MS) analysis without interference from heavy-chain fragments. Moreover, the acquisition of full MS scans under denaturing conditions allowed profiling of all abundant mAb glycoforms. Ultrahigh-resolution FTICR-MS measurements provided fully resolved isotopic distributions of intact mAb and enabled the identification of the most abundant adducts and other interfering species. Furthermore, it was found that reduction of interchain disulfide bonds occurs in the ESI source dependent on capillary voltage and solvent composition. This phenomenon was systematically evaluated and compared with the results obtained from reduction in the electrochemical cell.
Collapse
|
33
|
Nicolardi S, Giera M, Kooijman P, Kraj A, Chervet JP, Deelder AM, van der Burgt YEM. On-line electrochemical reduction of disulfide bonds: improved FTICR-CID and -ETD coverage of oxytocin and hepcidin. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2013; 24:1980-7. [PMID: 24018861 PMCID: PMC3837188 DOI: 10.1007/s13361-013-0725-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2013] [Revised: 07/25/2013] [Accepted: 07/25/2013] [Indexed: 05/21/2023]
Abstract
Particularly in the field of middle- and top-down peptide and protein analysis, disulfide bridges can severely hinder fragmentation and thus impede sequence analysis (coverage). Here we present an on-line/electrochemistry/ESI-FTICR-MS approach, which was applied to the analysis of the primary structure of oxytocin, containing one disulfide bridge, and of hepcidin, containing four disulfide bridges. The presented workflow provided up to 80% (on-line) conversion of disulfide bonds in both peptides. With minimal sample preparation, such reduction resulted in a higher number of peptide backbone cleavages upon CID or ETD fragmentation, and thus yielded improved sequence coverage. The cycle times, including electrode recovery, were rapid and, therefore, might very well be coupled with liquid chromatography for protein or peptide separation, which has great potential for high-throughput analysis.
Collapse
|
34
|
van den Broek I, Smit NPM, Romijn FPHTM, van der Laarse A, Deelder AM, van der Burgt YEM, Cobbaert CM. Evaluation of interspecimen trypsin digestion efficiency prior to multiple reaction monitoring-based absolute protein quantification with native protein calibrators. J Proteome Res 2013; 12:5760-74. [PMID: 24168082 DOI: 10.1021/pr400763d] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Implementation of quantitative clinical chemistry proteomics (qCCP) requires targeted proteomics approaches, usually involving bottom-up multiple reaction monitoring-mass spectrometry (MRM-MS) with stable-isotope labeled standard (SIS) peptides, to move toward more accurate measurements. Two aspects of qCCP that deserve special attention are (1) proper calibration and (2) the assurance of consistent digestion. Here, we describe the evaluation of tryptic digestion efficiency by monitoring various signature peptides, missed cleavages, and modifications during proteolysis of apolipoprotein A-I and B in normo- and hypertriglyceridemic specimens. Absolute quantification of apolipoprotein A-I and B was performed by LC-MRM-MS with SIS peptide internal standards at two time points (4 and 20 h), using three native protein calibrators. Comparison with an immunoturbidimetric assay revealed recoveries of 99.4 ± 6.5% for apolipoprotein A-I and 102.6 ± 7.2% for apolipoprotein B after 4 h of trypsin digestion. Protein recoveries after 20 h trypsin incubation equaled 95.9 ± 6.9% and 106.0 ± 10.0% for apolipoproteins A-I and B, respectively. In conclusion, the use of metrologically traceable, native protein calibrators looks promising for accurate quantification of apolipoprotein A-I and B. Selection of rapidly formed peptides, that is, with no or minor missed cleavages, and the use of short trypsin incubation times for these efficiently cleaved peptides are likely to further reduce the variability introduced by trypsin digestion and to improve the traceability of test results to reach the desirable analytical performance for clinical chemistry application.
Collapse
|
35
|
Jónasdóttir HS, Nicolardi S, Jonker W, Derks R, Palmblad M, Ioan-Facsinay A, Toes R, van der Burgt YEM, Deelder AM, Mayboroda OA, Giera M. Detection and Structural Elucidation of Esterified Oxylipids in Human Synovial Fluid by Electrospray Ionization-Fourier Transform Ion-Cyclotron Mass Spectrometry and Liquid Chromatography-Ion Trap-MS3: Detection of Esterified Hydroxylated Docosapentaenoic Acid Containing Phospholipids. Anal Chem 2013; 85:6003-10. [DOI: 10.1021/ac400826z] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
36
|
Nicolardi S, van der Burgt YEM, Dragan I, Hensbergen PJ, Deelder AM. Identification of new apolipoprotein-CIII glycoforms with ultrahigh resolution MALDI-FTICR mass spectrometry of human sera. J Proteome Res 2013; 12:2260-8. [PMID: 23527852 DOI: 10.1021/pr400136p] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Apolipoprotein-CIII (apoCIII) is an abundant blood glycoprotein associated with lipoprotein particles. Three different glycoforms have been described, all containing a mucin-type core-1 O-glycosylation with either zero, one or two sialic acids. Changes in the relative abundance of these glycoforms have been observed in a variety of different pathologies. In this study, ultrahigh resolution 15T MALDI Fourier transform ion cyclotron resonance (FTICR) MS was used to analyze apoCIII isoforms in serum protein profiles. For this purpose, serum proteins were purified using both a fully automated RPC18-based magnetic bead method and an RPC4 cartridge-based solid phase extraction method. Six new apoCIII isoforms were identified with low-ppm mass measurement errors and ultrahigh precision. These were characterized by more complex glycan moieties that are fucosylated instead of sialylated. To confirm the glycan moiety and localize the glycosylation site, top-down ESI-FTICR-MS/MS and bottom-up LC-ion trap MS/MS were used. A large variation in the presence and abundance of the fucosylated isoforms was found in a set of 96 serum samples. These findings of fucosylated apolipoprotein-CIII isoforms warrant further research to elucidate the implications these glycoforms may have for the plethora of studies where alterations in apoCIII have been linked to the development of many different pathologies.
Collapse
|
37
|
Nicolardi S, van der Burgt YEM, Wuhrer M, Deelder AM. Mapping O-glycosylation of apolipoprotein C-III in MALDI-FT-ICR protein profiles. Proteomics 2013; 13:992-1001. [PMID: 23335445 DOI: 10.1002/pmic.201200293] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2012] [Revised: 08/29/2012] [Accepted: 10/23/2012] [Indexed: 01/10/2023]
Abstract
Ultrahigh resolution MALDI-FT-ICR profiles were obtained from human serum samples that were processed using a fully automated RPC18-based magnetic bead method. Proteins were profiled from m/z value 6630 with a resolving power of 73 000 up to m/z value 12 600 with a resolving power of 37 000. In this study, a detailed evaluation was performed of the isoforms of apolipoprotein C-III, i.e. the different mucin-type core 1 O-glycans with the addition of one or two sialic acid residues. The MALDI-FT-ICR profiles are discussed with regard to reproducibility of the signal intensities as well as the accurate mass measurements. ESI-FT-ICR-MS/MS analyses of the same serum samples were performed to confirm the identity of apolipoprotein C-III glycoforms.
Collapse
|
38
|
Bladergroen MR, Derks RJE, Nicolardi S, de Visser B, van Berloo S, van der Burgt YEM, Deelder AM. Standardized and automated solid-phase extraction procedures for high-throughput proteomics of body fluids. J Proteomics 2012; 77:144-53. [PMID: 22842157 DOI: 10.1016/j.jprot.2012.07.023] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2012] [Revised: 07/04/2012] [Accepted: 07/16/2012] [Indexed: 01/17/2023]
Abstract
In order to balance the speed of analytical sample preparation procedures with mass spectrometry (MS)-based clinical proteomics the application of high-throughput robotic systems for body fluid workup is essential. In this paper we describe the implementation of various solid-phase extraction (SPE) sample preparation protocols on two different platforms, namely: 1) Magnetic bead-based SPE of peptides and proteins from body fluids on a Hamilton liquid handling workstation; 2) Cartridge-based SPE on a SPARK Symbiosis system. All SPE protocols were optimized for MS-based proteomics and compared with respect to obtained peptide- and protein profiles. Throughput numbers that were achieved in a 24 hour time frame for the sample workup procedures were more than 700 samples for the magnetic bead-based method and over 1000 samples for the cartridge-based method.
Collapse
|
39
|
Velstra B, van der Burgt YEM, Mertens BJ, Mesker WE, Deelder AM, Tollenaar RAEM. Improved classification of breast cancer peptide and protein profiles by combining two serum workup procedures. J Cancer Res Clin Oncol 2012; 138:1983-92. [PMID: 22763645 PMCID: PMC3491194 DOI: 10.1007/s00432-012-1273-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2012] [Accepted: 06/15/2012] [Indexed: 12/22/2022]
Abstract
Purpose Detection of breast cancer at early stage increases patient’s survival. Mass spectrometry-based protein analysis of serum samples is a promising approach to obtain biomarker profiles for early detection. A combination of commonly applied solid-phase extraction procedures for clean-up may increase the number of detectable peptides and proteins. In this study, we have evaluated whether the classification performance of breast cancer profiles improves by using two serum workup procedures. Methods Serum samples from 105 breast cancer patients and 202 healthy volunteers were processed according to a standardized protocol implemented on a high-end liquid-handling robot. Peptide and protein enrichments were carried out using weak-cation exchange (WCX) and reversed-phase (RP) C18 magnetic beads. Profiles were acquired on a matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometer. In this way, two different biomarker profiles were obtained for each serum sample, yielding a WCX- and RPC18-dataset. Results The profiles were statistically evaluated with double cross-validation. Classification results of WCX- and RPC18-datasets were determined for each set separately and for the combination of both sets. Sensitivity and specificity were 82 and 87 % (WCX) and 73 and 93 % (RPC18) for the individual workup procedures. These values increased up to 84 and 95 %, respectively, upon combining the data. Conclusion It was found that MALDI-TOF peptide and protein profiles can be used for classification of breast cancer with high sensitivity and specificity. The classification performance even improved when two workup procedures were applied, since these provide a greater number of features (proteins). Electronic supplementary material The online version of this article (doi:10.1007/s00432-012-1273-4) contains supplementary material, which is available to authorized users.
Collapse
|
40
|
Nicolardi S, Andreoni A, Tabares LC, van der Burgt YEM, Canters GW, Deelder AM, Hensbergen PJ. Top-down FTICR MS for the identification of fluorescent labeling efficiency and specificity of the Cu-protein azurin. Anal Chem 2012; 84:2512-20. [PMID: 22320330 DOI: 10.1021/ac203370f] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Fluorescent protein labeling has been an indispensable tool in many applications of biochemical, biophysical, and cell biological research. Although detailed information about the labeling stoichiometry and exact location of the label is often not necessary, for other purposes, this information is crucial. We have studied the potential of top-down electrospray ionization (ESI)-15T Fourier transform ion cyclotron resonance (FTICR) mass spectrometry to study the degree and positioning of fluorescent labeling. For this purpose, we have labeled the Cu-protein azurin with the fluorescent label ATTO 655-N-hydroxysuccinimide(NHS)-ester and fractionated the sample using anion exchange chromatography. Subsequently, individual fractions were analyzed by ESI-15T FTICR to determine the labeling stoichiometry, followed by top-down MS fragmentation, to locate the position of the label. Results showed that, upon labeling with ATTO 655-NHS, multiple different species of either singly or doubly labeled azurin were formed. Top-down fragmentation of different species, either with or without the copper, resulted in a sequence coverage of approximately 50%. Different primary amine groups were found to be (potential) labeling sites, and Lys-122 was identified as the major labeling attachment site. In conclusion, we have demonstrated that anion exchange chromatography in combination with ultrahigh resolution 15T ESI-FTICR top-down mass spectrometry is a valuable tool for measuring fluorescent labeling efficiency and specificity.
Collapse
|
41
|
Nicolardi S, Palmblad M, Hensbergen PJ, Tollenaar RAEM, Deelder AM, van der Burgt YEM. Precision profiling and identification of human serum peptides using Fourier transform ion cyclotron resonance mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:3457-3463. [PMID: 22095492 DOI: 10.1002/rcm.5246] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Many biomarker discovery studies are based on matrix-assisted laser desorption/ionisation (MALDI) peptide profiles. In this study, 96 human serum samples were analysed on a Bruker solariX(TM) MALDI Fourier transform ion cyclotron resonance (FTICR) system equipped with a 15 tesla magnet. Isotopically resolved peptides were observed in ultrahigh resolution FTICR profiles up to m/z 6500 with mass measurement errors (MMEs) of previously identified peptides at a sub-ppm level. For comparison with our previous platform for peptide profile mass analysis (i.e. Ultraflex II) the corresponding time-of-flight (TOF) spectra were obtained with isotopically resolved peptides up to m/z 3500. The FTICR and TOF systems performed rather similar with respect to the repeatability of the signal intensities. However, the mass measurement precision improved at least 10-fold in ultrahigh resolution data and thus simplified spectral alignment necessary for robust and quantitatively precise comparisons of profiles in large-scale clinical studies. From each single MALDI-FTICR spectrum an m/z-list was obtained with sub-ppm precision for all different species, which is beneficial for identification purposes and interlaboratory comparisons. Furthermore, the FTICR system allowed new peptide identifications from collision-induced dissociation (CID) spectra using direct infusion of reversed-phase (RP) C(18)-fractionated serum samples on an electrospray ionisation (ESI) source.
Collapse
|
42
|
Wuhrer M, Deelder AM, van der Burgt YEM. Mass spectrometric glycan rearrangements. MASS SPECTROMETRY REVIEWS 2011; 30:664-80. [PMID: 21560141 DOI: 10.1002/mas.20337] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2010] [Revised: 02/28/2011] [Accepted: 03/28/2011] [Indexed: 05/04/2023]
Abstract
Mass spectrometric rearrangement reactions have been reported for a large variety of compounds such as peptides, lipids, and carbohydrates. In the case of carbohydrates this phenomenon has been described as internal residue loss. Resulting fragment ions may be misinterpreted as fragments arising from conventional glycosidic bond cleavages, which may result in incorrect structural assignment. Therefore, awareness of the occurrence of glycan rearrangements is important for avoiding misinterpretation of tandem mass spectra. In this review mass spectrometric rearrangements of both derivatized and underivatized (native) oligosaccharide structures are discussed. Similar phenomena have been reported for glycopeptides, labeled glycan structures and other biomolecules containing a carbohydrate part. Rearrangements in oligosaccharides and glycoconjugates have been observed with different types of mass spectrometers. Most of the observed carbohydrate rearrangement reactions appear to be linked to the presence of a proton. Hence, tandem mass spectrometric analysis of alkali adducts or deprotonated ions often prevents rearrangement reactions, while they may happen with high efficacy with protonated glycoconjugates.
Collapse
|
43
|
Huijbers A, Velstra B, Dekker TJA, Mesker WE, van der Burgt YEM, Mertens BJ, Deelder AM, Tollenaar RAEM. Proteomic serum biomarkers and their potential application in cancer screening programs. Int J Mol Sci 2010; 11:4175-93. [PMID: 21151433 PMCID: PMC3000077 DOI: 10.3390/ijms11114175] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2010] [Revised: 10/16/2010] [Accepted: 10/18/2010] [Indexed: 02/06/2023] Open
Abstract
Early diagnosis of cancer is of pivotal importance to reduce disease-related mortality. There is great need for non-invasive screening methods, yet current screening protocols have limited sensitivity and specificity. The use of serum biomarkers to discriminate cancer patients from healthy persons might be a tool to improve screening programs. Mass spectrometry based proteomics is widely applied as a technology for mapping and identifying peptides and proteins in body fluids. One commonly used approach in proteomics is peptide and protein profiling. Here, we present an overview of profiling methods that have the potential for implementation in a clinical setting and in national screening programs.
Collapse
|
44
|
Blanckenburg B, van der Burgt YEM, Deelder AM, Palmblad M. "Lossless" compression of high resolution mass spectra of small molecules. Metabolomics 2010; 6:335-340. [PMID: 20676216 PMCID: PMC2899016 DOI: 10.1007/s11306-010-0202-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2009] [Accepted: 02/10/2010] [Indexed: 01/30/2023]
Abstract
Fourier transform ion cyclotron resonance (FTICR) provides the highest resolving power of any commercially available mass spectrometer. This advantage is most significant for species of low mass-to-charge ratio (m/z), such as metabolites. Unfortunately, FTICR spectra contain a very large number of data points, most of which are noise. This is most pronounced at the low m/z end of spectra, where data point density is the highest but peak density low. We therefore developed a filter that offers lossless compression of FTICR mass spectra from singly charged metabolites. The filter relies on the high resolving power and mass measurement precision of FTICR and removes only those m/z channels that cannot contain signal from singly charged organic species. The resulting pseudospectra still contain the same signal as the original spectra but less uninformative background. The filter does not affect the outcome of standard downstream chemometric analysis methods, such as principal component analysis, but use of the filter significantly reduces memory requirements and CPU time for such analyses. We demonstrate the utility of the filter for urinary metabolite profiling using direct infusion electrospray ionization and a 15 tesla FTICR mass spectrometer. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11306-010-0202-2) contains supplementary material, which is available to authorized users.
Collapse
|
45
|
Nicolardi S, Palmblad M, Dalebout H, Bladergroen M, Tollenaar RAEM, Deelder AM, van der Burgt YEM. Quality control based on isotopic distributions for high-throughput MALDI-TOF and MALDI-FTICR serum peptide profiling. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2010; 21:1515-1525. [PMID: 20541438 DOI: 10.1016/j.jasms.2010.05.004] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2010] [Revised: 04/23/2010] [Accepted: 05/06/2010] [Indexed: 05/29/2023]
Abstract
In this study, we have implemented a new quality control (QC) parameter for peptide profiling based on isotopic distributions. This QC parameter is an objective measure and facilitates automatic sorting of large numbers of peptide spectra. Peptides in human serum samples were enriched using reversed-phase C(18)-functionalized magnetic beads using a high-throughput robotic platform. High-resolution MALDI-TOF and ultrahigh resolution MALDI-FTICR mass spectra were obtained and a workflow was developed for automated analysis and evaluation of these profiles. To this end, the isotopic distributions of multiple peptides were quantified from both MALDI-TOF and MALDI-FTICR spectra. Odd peptide isotope distributions in TOF spectra could be rationalized from ultrahigh resolution FTICR spectra that showed overlap of different peptides. The comparison of isotope patterns with estimated polyaveragine distributions was used to calculate a QC value for each single mass spectrum. Sorting these QC values enabled the best MALDI spectrum to be selected from replicate spots. Moreover, using this approach spectra containing high intensities of polymers or other contaminants and lacking peptides of interest can be efficiently removed from a clinical dataset. In general, this method simplifies the exclusion of low quality spectra from further statistical analysis.
Collapse
|
46
|
Palmblad M, van der Burgt YEM, Mostovenko E, Dalebout H, Deelder AM. A novel mass spectrometry cluster for high-throughput quantitative proteomics. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2010; 21:1002-1011. [PMID: 20194034 DOI: 10.1016/j.jasms.2010.02.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2009] [Revised: 02/01/2010] [Accepted: 02/01/2010] [Indexed: 05/28/2023]
Abstract
We have developed and implemented a novel mass spectrometry (MS) platform combining the advantages of high mass accuracy and resolving power of Fourier transform ion cyclotron resonance (FTICR) with the economy and speed of multiple ion traps for tandem mass spectrometry. The instruments are integrated using novel algorithms and software and work in concert as one system. Using chromatographic time compression, a single expensive FTICR mass spectrometer can match the throughput of multiple relatively inexpensive ion trap instruments. Liquid chromatography (LC)-mass spectrometry data from the two types of spectrometers are aligned and combined to hybrid datasets, from which peptides are identified using accurate mass from the FTICR data and tandem mass spectra from the ion trap data. In addition, the high resolving power and dynamic range of a 12 tesla FTICR also allows precise label-free quantitation. Using two ion traps in parallel with one LC allows simultaneous MS/MS experiments and optimal application of collision induced dissociation and electron-transfer dissociation throughout the chromatographic separation for increased proteome coverage, characterization of post-translational modifications and/or simultaneous measurement in positive and negative ionization mode. An FTICR-ion trap cluster can achieve similar performance and sample throughput as multiple hybrid ion trap-FTICR instruments, but at a lower cost. We here describe the first such FTICR-ion trap cluster, its performance and the idea of chromatographic compression.
Collapse
|
47
|
Barbu IMT, Smith DF, van Breukelen B, van der Burgt YEM, Duursma MC, Heck AJR, Heeren RMA, Krijgsveld J. On-the-fly targeted selection of labeled peptides in liquid chromatography/mass spectrometry based quantitative proteomics. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2010; 24:239-241. [PMID: 20013948 DOI: 10.1002/rcm.4385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
48
|
Palmblad M, van der Burgt YEM, Dalebout H, Derks RJE, Schoenmaker B, Deelder AM. Improving mass measurement accuracy in mass spectrometry based proteomics by combining open source tools for chromatographic alignment and internal calibration. J Proteomics 2009; 72:722-4. [PMID: 19167529 DOI: 10.1016/j.jprot.2008.12.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2008] [Accepted: 12/31/2008] [Indexed: 10/21/2022]
Abstract
Accurate mass determination enhances peptide identification in mass spectrometry based proteomics. We here describe the combination of two previously published open source software tools to improve mass measurement accuracy in Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS). The first program, msalign, aligns one MS/MS dataset with one FTICRMS dataset. The second software, recal2, uses peptides identified from the MS/MS data for automated internal calibration of the FTICR spectra, resulting in sub-ppm mass measurement errors.
Collapse
|
49
|
van der Burgt YEM, Palmblad M, Dalebout H, Heeren RMA, Deelder AM. Electron capture dissociation of peptide hormone changes upon opening of the tocin ring and complexation with transition metal cations. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:31-38. [PMID: 19051230 DOI: 10.1002/rcm.3849] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Electron capture dissociation (ECD) is an analytical technique in mass spectrometry (MS) that allows detailed structural study of biomolecules to gain insight in their function. In this work the ECD behavior of two peptide hormones oxytocin (OT1) and vasopressin (VP1) was studied. The results of OT1 and VP1 were compared to structural analogues OT2 and VP2, which have similar amino acid sequences but lack the tocin ring. The ECD results showed that both the fragment type (c/z versus b/y) and the cleavage sites (ring versus tail) changed upon opening of the tocin ring. All four peptides were complexed with three different transition metal cations (Zn(2+), Ni(2+) and Cu(2+)) and the ECD results were compared to those obtained from the doubly protonated species. The use of various metal ions yielded different cleavages sites within the same peptide. This can be an effect of the metal ion itself, or a consequence of a change in conformation as was suggested earlier. In addition, the type of fragment ion varied for each metal-complexed peptide, which is in agreement with previous observations.
Collapse
|
50
|
Taban IM, van der Burgt YEM, Duursma M, Takáts Z, Seynen M, Konijnenburg M, Vijftigschild A, Attema I, Heeren RMA. A novel workflow control system for Fourier transform ion cyclotron resonance mass spectrometry allows for unique on-the-fly data-dependent decisions. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:1245-56. [PMID: 18383214 DOI: 10.1002/rcm.3440] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
In this paper a novel workflow-based data acquisition and control system for Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is presented that facilitates a fast on-the-fly decision-making process for a wide variety of data-dependent experiments. Several new workflow implementations demonstrate the flexibility and benefit of this approach for rapid dynamic experimental design on a chromatographic timescale. The different sequence, evaluation, decision and monitoring modules are described using a selected set of examples. During a tandem liquid chromatography (LC)/FTICR-MS experiment the system is used to dynamically switch between various dissociation techniques such as electron capture dissociation (ECD) and sustained off-resonance irradiation (SORI) depending on the charge state of a tryptic peptide peak. The use of this workflow-based system for imaging FTICR-MS using a desorption electrospray ionization (DESI) source demonstrates the possibility of external control of the workflow by feedback from an imaging sample stage.
Collapse
|